I want to search for...
Permit #2022011153
Permit Details
Status: FINAL
| Parcel Id: 07-11-31-7057-00690-0030 |
| GARAGE: 624 sqft |
| CONDITIONED SPACE: 874 sqft |
| OPENED PORCH (WITH ROOF) : 1192 sqft |
| GARAGE: 101 sqft |
| Total Square Footage: 2791 sqft |
| Block: 00690 |
| Subdivision: - |
| Job Phone: 386-263-8272 |
| Location Address: 164 ULYSSES TR |
| Type: BA - BUILDING ADDITION |
| Issue Date: 03/01/2022 |
| NOC: RECORDED |
| Applicant name: ROY CHARLES WALDHAUER |
| Owner: PACI VICTOR JR & BROOKE H&W |
|
Address 164 ULYSSES TRAIL PALM COAST, FL 32164 |
| Lot: 0030 |
| Contracted Stated Job Value: ¤187,000.00 |
| Job Description: ADDITION |
| Type: CN |
Contractor
BY THE SHORE INC.
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
1600 N STATE STREET # 102 , |
CRC1327300 (Exp: 08/31/2026) | 386-263-8272 | 386-263-8289 |
Sub Contractors
THOMAS A REGULA
| Status | Location Address | State License Number | Phone | Fax |
| INACTIVE |
11320 PHILLIPS PKWY DRIVE E JACKSONVILLE, FL 32256 |
CMC1250075 (Exp: 08/31/2026) | 904-278-0339 | 904-278-0366 |
DANIEL DAVID RUTKOWSKI III
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
1687 STATE AVENUE HOLLY HILL, FL 32117 |
CCC1328639 (Exp: 08/31/2026) | 386-290-7490 | 386-256-0001 |
WILLIAM FRANK DUDLEY JR.
| Status | Location Address | State License Number | Phone |
| ACTIVE |
P.O. BOX 978 Bunnell, FL 32110 |
EC0003177 (Exp: 08/31/2026) | (386)437-3068 |
HEATH EDWARD SANFORD
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
1351 HAZELNUT ST BUNNELL, FL 32110 |
CFC1427527 (Exp: 08/31/2026) | 386-445-2532 | 386-445-5575 |
Inspection History
| Type | Request Date | Result | Inspector |
| BLD - BUILDING FINAL | 02/08/2023 | FINAL APPROVED | BTAYLOR |
| Note: 2/3/2023 - PREVIOUS INSPECTION NOTES revision needed for corrected plans and energy calcs FBC 107.3 1. Energy calcs call for R-38 insulation in attic, Plans show vented attic, Attic space is unvented with foam insulation dirrectly applied to the roof deck, and unsulation certification on site shows R-20. 2. Need shcedule 40 cap on DWV for future sink in garage…. P3005.1.5 (per home owner the sink cabinet is on extended back order, sink is shown on plans) | |||
| BLD - BUILDING FINAL | 02/03/2023 | Disapproved - NO FEE | LMILLER |
| Note: revision needed for corrected plans and energy calcs FBC 107.3 1. Energy calcs call for R-38 insulation in attic, Plans show vented attic, Attic space is unvented with foam insulation dirrectly applied to the roof deck, and unsulation certification on site shows R-20. 2. Need shcedule 40 cap on DWV for future sink in garage…. P3005.1.5 (per home owner the sink cabinet is on extended back order, sink is shown on plans) | |||
| ROW FIELD SURVEY /GRADING CERTIFICATION | 02/02/2023 | APPROVED | GBERTOLA |
| Note: 02/2/23= AT THE TIME OF THE INSPECTION EVERYTHING LOOK GOOD | |||
| ROW - FINAL INSPECTION | 02/02/2023 | APPROVED | GBERTOLA |
| Note: AT THE TIME OF THE INSPECTION EVERYTHING LOOK GOOD | |||
| U -UTILITY RESIDENTIAL FINAL | 02/02/2023 | FINAL APPROVED | JHARDING |
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 02/01/2023 | APPROVED - AS NOTED | PFLANAGAN |
| Note: AFTER FURTHER REVIEW THE SOD ELEVATIONS WAS BELOW THE FFE THE RIGHT AMOUNT PLEASE CONTACT PARREN FOR ANY QUESTIONS -------------------------------------------------------------------------- 1/24/2023 - PREVIOUS INSPECTION NOTES SOD ELEVATIONS UP AGAINST THE STRUCTURE NEEDS TO BE 4" BELOW THE FEE ON A CONCRETE STRUCTURE AND 6" BELOW THE FFE OF A WOOD FRAME STRUCTURE. | |||
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 01/24/2023 | Disapproved - NO FEE | PFLANAGAN |
| Note: SOD ELEVATIONS UP AGAINST THE STRUCTURE NEEDS TO BE 4" BELOW THE FEE ON A CONCRETE STRUCTURE AND 6" BELOW THE FFE OF A WOOD FRAME STRUCTURE. | |||
| U - SEWER TIE IN | 12/27/2022 | APPROVED | MGIBSON |
| GRAVITY SEWER TEST | 12/27/2022 | APPROVED | MGIBSON |
| Note: Inspector Notes from Inspection 2060 PROVIDE PORTABLE RESTROOM BEFORE SHEDULING MONOLITHIC SLAB INSPECTION | |||
| ELECTRIC - EARLY POWER | 12/01/2022 | APPROVED | BTAYLOR |
| LATH/BRICK/ WATER BARRIER | 09/26/2022 | APPROVED | BTAYLOR |
| Note: 9/22/2022 - PREVIOUS INSPECTION NOTES | |||
| INSULATION | 09/26/2022 | APPROVED | BTAYLOR |
| Note: 9/22/2022 - PREVIOUS INSPECTION NOTES 9/21/2022 - PREVIOUS INSPECTION NOTES 9/20/2022 - PREVIOUS INSPECTION NOTES 9-20-22 1. Holes in garage wall need fire foam.(Small space with bat pulled down.) 2. Fridge wire needs fire foam. 3. Need fire blocking and fire foam above slider in back room. 9-21-22 1. Need fire blocking and fire foam above slider in back room. | |||
| LATH/BRICK/ WATER BARRIER | 09/22/2022 | CANCELLED BY APPLICANT | BTAYLOR |
| INSULATION | 09/22/2022 | CANCELLED BY APPLICANT | BTAYLOR |
| Note: 9/21/2022 - PREVIOUS INSPECTION NOTES 9/20/2022 - PREVIOUS INSPECTION NOTES 9-20-22 1. Holes in garage wall need fire foam.(Small space with bat pulled down.) 2. Fridge wire needs fire foam. 3. Need fire blocking and fire foam above slider in back room. 9-21-22 1. Need fire blocking and fire foam above slider in back room. | |||
| INSULATION | 09/21/2022 | Disapproved - NO FEE | BTAYLOR |
| Note: 9/20/2022 - PREVIOUS INSPECTION NOTES 9-20-22 1. Holes in garage wall need fire foam.(Small space with bat pulled down.) 2. Fridge wire needs fire foam. 3. Need fire blocking and fire foam above slider in back room. 9-21-22 1. Need fire blocking and fire foam above slider in back room. | |||
| INSULATION | 09/20/2022 | Disapproved - NO FEE | BTAYLOR |
| Note: 9-20-22 1. Holes in garage wall need fire foam.(Small space with bat pulled down.) 2. Fridge wire needs fire foam. 3. Need fire blocking and fire foam above slider in back room. | |||
| ALL ROUGH | 09/14/2022 | APPROVED | BTAYLOR |
| Note: Inspector Notes from Inspection 2460 THIS IS A REINSPECTION 9-13-22 1. Need strap on triple in breeze way both sides. 2. Need strap on rafter above pool equipment in breeze way. | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 09/13/2022 | APPROVED - AS NOTED | BTAYLOR |
| Note: THIS IS A REINSPECTION 9-13-22 1. Need strap on triple in breeze way both sides. 2. Need strap on rafter above pool equipment in breeze way. | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 09/09/2022 | CANCELLED BY APPLICANT | BTAYLOR |
| ROOF VALLEY & METAL | 08/19/2022 | APPROVED | BTAYLOR |
| ROOF SHEATHING | 08/15/2022 | APPROVED | DCUSHING |
| TIE BEAM / LINTEL | 07/08/2022 | APPROVED | TSTAUFFACHER |
| Note: THIS IS A REINSPECTION Plans incomplete/out of order/not all pages approved Tie in to existing house detail not provided Tie into house not exposed for inspection | |||
| TIE BEAM / LINTEL | 06/24/2022 | Disapproved - NO FEE | TSTAUFFACHER |
| Note: Plans incomplete/out of order/not all pages approved Tie in to existing house detail not provided Tie into house not exposed for inspection | |||
| FOUND SURVEY APPROVED (OFFICE) | 06/24/2022 | APPROVED | TBAKER |
| MONOLITHIC SLAB | 05/06/2022 | APPROVED - AS NOTED | DCUSHING |
| Note: mono slab and column pads @ breezeway | |||
| PLUMBING 1ST ROUGH UNDERGROUND | 04/05/2022 | APPROVED - AS NOTED | MGIBSON |
| Note: PROVIDE PORTABLE RESTROOM BEFORE SHEDULING MONOLITHIC SLAB INSPECTION |
Review History
| Department | Status | Date In | Date Out |
| MECH | HOLD | 02/06/2023 | 02/06/2023 |
| Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Provide heatload and duct layout | |||
| MECH | COMPLETE | 02/06/2023 | 02/06/2023 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 11/16/2022 | 11/16/2022 |
| Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM | |||
| ZON | HOLD | 11/15/2022 | 11/16/2022 |
| Note: Held By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM Scanned copy is hard to read what is written where you whited out the piece that isn't allowed but it looks like it shows concrete and that would be a patio and still connected to the driveway making it part of the driveway. This is not allowed. Driveways must lead to a garage. | |||
| ZON | HOLD | 11/07/2022 | 11/07/2022 |
| Note: Held By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM Proposed site plan doesn't match landscape plan. You are showing on the landscape plan a car parked passed the garage entry. This is not allowed. Driveways must lead to a garage. | |||
| ENGIN1 | COMPLETE | 11/07/2022 | 11/07/2022 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| SW1 | COMPLETE | 11/07/2022 | 11/15/2022 |
| Note: Released By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM | |||
| ZON | HOLD | 10/31/2022 | 11/01/2022 |
| Note: Held By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM Proposed site plan doesn't match landscape plan. Driveway at the widest point cannot exceed 36ft maximum for a two car garage. The way you have it they are still connected which exceeds what is allowed. The patio and driveway cannot be connected. There must be a seperation. Please provide dimensions and make sure once approved the landscape plan must match your proposed approved site plan. | |||
| ENGIN1 | COMPLETE | 10/31/2022 | 10/31/2022 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| SW1 | COMPLETE | 10/31/2022 | 11/04/2022 |
| Note: Released By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM | |||
| ZON | HOLD | 10/24/2022 | 10/25/2022 |
| Note: Held By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM Proposed site plan doesn't match landscape plan. Driveway at the widest point cannot exceed 36ft maximum for a two car garage. | |||
| ZON | HOLD | 10/19/2022 | 10/19/2022 |
| Note: Held By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM Landscape plan driveway layout doesn't match the proposed approved site plan There must be a total of 8 trees. Please show all existing and what is being added | |||
| BLD | COMPLETE | 06/30/2022 | 07/05/2022 |
| Note: Released By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 06/24/2022 | 06/24/2022 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 06/24/2022 | 06/24/2022 |
| Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 05/09/2022 | 05/09/2022 |
| Note: Released By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM | |||
| BLD | HOLD | 04/25/2022 | 04/26/2022 |
| Note: Held By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM All comments below per the 2020 Florida Building Code – Residential REVIEW COMMENTS: 1. Multiple Span tales and methods have been submitted. Provide if the Engineered or Prescriptive Method is to be used. FBC [A]107. 2. Option #2, 2x4 SP, Total Span of 2x6 is noted for 2x4 span. Revise to reflect the correct span. FBC [A]107. | |||
| BLD | HOLD | 03/30/2022 | 03/31/2022 |
| Note: Held By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM All comments below per the 2020 Florida Building Code REVIEW COMMENTS: 1. Proposed 2 x 10 rafters appear over spanned per the 2018 Wood Frame Construction Manual. A revision is required. FC 107 2. Provide sizes of proposed wood headers that being installed in place of the precast concrete lintels. | |||
| BLD | COMPLETE | 03/23/2022 | 03/24/2022 |
| Note: Released By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM | |||
| BADMIN | COMPLETE | 02/10/2022 | 02/10/2022 |
| Note: Released By: LIBBY MUSGROVE - - LMUSGROVE@PALMCOASTGOV.COM | |||
| ELEC | COMPLETE | 02/10/2022 | 02/10/2022 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 02/10/2022 | 02/10/2022 |
| Note: Released By: FRED REODICA - (386)986-4734 - FREODICA@PALMCOASTGOV.COM Correction for zoning on sheet 1 of 2 re. stucco band on left side elevation. Building review - NA. | |||
| BADMIN | INFORMATION | 02/09/2022 | 02/09/2022 |
| Note: Held By: BARBIE BEMBRY - (386)986-3780 - BUILDINGDIVISION@PALMCOASTGOV.COM This permit was created/started manually. Until the permit is issued, the same process must be followed. We do not allow for electronic/manual submissions to mix. | |||
| ELEC | HOLD | 02/03/2022 | 02/04/2022 |
| Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. Can lights in garage need to be fire rated submit spec on can lights. FRC 2020 302.5.3 2. Submit load calcs with the new square footage and the size of the existing service. NEC 2017 220.83 | |||
| ZON | COMPLETE | 02/03/2022 | 02/04/2022 |
| Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM | |||
| SW1 | COMPLETE | 02/03/2022 | 02/09/2022 |
| Note: Released By: PARREN FLANAGAN - - PFLANAGAN@PALMCOASTGOV.COM | |||
| BLD | HOLD | 02/03/2022 | 02/09/2022 |
| Note: Held By: FRED REODICA - (386)986-4734 - FREODICA@PALMCOASTGOV.COM Correction: Submited Sheet 1 of 2 ( Elevation views) dated 2/3/2022 appears exactly the same as Original Elevation Views. Please identify the change(s) made for clarity per FBC 7th Ed. Sec. 107.3. | |||
| ZON | HOLD | 01/25/2022 | 01/27/2022 |
| Note: Held By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM Completing paperwork for the agreement. Once termination of easement agreement is completed we will email for owners signature and notary. Original must be turned into to us for recording. Please provide setbacks from addition to property lines on site plan/survey. Please show on landscape plan the four required trees. Whether existing or adding them please note them on landscape plan for review. Banding must wrap corners at least two feet Garage depth cannot exceed 30ft max Garage space cannot exceed 50% of the living square footage. With addition and house total is 2918. Per the proposed plans and what is existing garage space totals 1486 which is 27ft over. Per the calculations garage space can only total 1459. Please have owners complete a Single family Dwelling Affidavit and turn original in to us for recording | |||
| BLD | COMPLETE | 01/25/2022 | 01/26/2022 |
| Note: Released By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM | |||
| ELEC | HOLD | 01/25/2022 | 01/26/2022 |
| Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. Can lights in garage need to be fire rated submit spec on can lights. FBC 2020 714 2. Outlets in screen room, garage, bathroom, outside , and bar area need to be GFCI protected. NEC 207 210.8 3. Need outlets on bar countertop NEC 2017 210.52 (C). 4. Submit load calcs with the new square footage and the size of the existing service. NEC 2017 220.83 | |||
| MECH | COMPLETE | 01/25/2022 | 01/26/2022 |
| Note: Released By: CHRIS PISCITELLI - (386)986-3782 - CPISCITELLI@PALMCOASTGOV.COM | |||
| PLUM | COMPLETE | 01/25/2022 | 01/26/2022 |
| Note: Released By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM | |||
| SW1 | COMPLETE | 01/25/2022 | 02/01/2022 |
| Note: Released By: PARREN FLANAGAN - - PFLANAGAN@PALMCOASTGOV.COM |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| PLAN REVIEW - REVISION | ¤32.50 | 02/02/2023 |
| PLAN REVIEW - REVISION | ¤32.50 | 02/02/2023 |
| PLAN REVIEW - REVISION | ¤32.50 | 02/02/2023 |
| RECORDING FEE REIMBURSE DOC | ¤35.50 | 03/01/2022 |
| RECORDING FEE REIMBURSE DOC | ¤10.00 | 03/01/2022 |
| SURCHARGE FS 533.721 | ¤7.39 | 03/01/2022 |
| SURCHARGE - FS 468.631 | ¤11.08 | 03/01/2022 |
| SW ENG - INSPECTION 20 | ¤20.00 | 03/01/2022 |
| SW ENG - REVIEW 20 | ¤20.00 | 03/01/2022 |
| SITE PLAN 30 | ¤30.00 | 03/01/2022 |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | 03/01/2022 |
| INSPECTION - RESIDENTIAL | ¤514.25 | 03/01/2022 |
| PLAN REVIEW - RESIDENTIAL | ¤145.86 | 03/01/2022 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤921.58 |