I want to search for...

Permit #2022011153

Permit Details

Status: FINAL

Parcel Id: 07-11-31-7057-00690-0030
GARAGE: 624 sqft
CONDITIONED SPACE: 874 sqft
OPENED PORCH (WITH ROOF) : 1192 sqft
GARAGE: 101 sqft
Total Square Footage: 2791 sqft
Block: 00690
Subdivision: -
Job Phone: 386-263-8272
Location Address: 164 ULYSSES TR
Type: BA - BUILDING ADDITION
Issue Date: 03/01/2022
NOC: RECORDED
Applicant name: ROY CHARLES WALDHAUER
Owner: PACI VICTOR JR & BROOKE H&W

Address

164 ULYSSES TRAIL

PALM COAST, FL 32164

Lot: 0030
Contracted Stated Job Value: ¤187,000.00
Job Description: ADDITION
Type: CN

Contractor

BY THE SHORE INC.
Status Location Address State License Number Phone Fax
ACTIVE

1600 N STATE STREET # 102

,

CRC1327300 (Exp: 08/31/2026) 386-263-8272 386-263-8289

Sub Contractors

THOMAS A REGULA
Status Location Address State License Number Phone Fax
INACTIVE

11320 PHILLIPS PKWY DRIVE E

JACKSONVILLE, FL 32256

CMC1250075 (Exp: 08/31/2026) 904-278-0339 904-278-0366
DANIEL DAVID RUTKOWSKI III
Status Location Address State License Number Phone Fax
ACTIVE

1687 STATE AVENUE

HOLLY HILL, FL 32117

CCC1328639 (Exp: 08/31/2026) 386-290-7490 386-256-0001
WILLIAM FRANK DUDLEY JR.
Status Location Address State License Number Phone
ACTIVE

P.O. BOX 978

Bunnell, FL 32110

EC0003177 (Exp: 08/31/2026) (386)437-3068
HEATH EDWARD SANFORD
Status Location Address State License Number Phone Fax
ACTIVE

1351 HAZELNUT ST

BUNNELL, FL 32110

CFC1427527 (Exp: 08/31/2026) 386-445-2532 386-445-5575

Inspection History

Type Request Date Result Inspector
BLD - BUILDING FINAL 02/08/2023 FINAL APPROVED BTAYLOR
Note: 2/3/2023 - PREVIOUS INSPECTION NOTES revision needed for corrected plans and energy calcs FBC 107.3 1. Energy calcs call for R-38 insulation in attic, Plans show vented attic, Attic space is unvented with foam insulation dirrectly applied to the roof deck, and unsulation certification on site shows R-20. 2. Need shcedule 40 cap on DWV for future sink in garage…. P3005.1.5 (per home owner the sink cabinet is on extended back order, sink is shown on plans)
BLD - BUILDING FINAL 02/03/2023 Disapproved - NO FEE LMILLER
Note: revision needed for corrected plans and energy calcs FBC 107.3 1. Energy calcs call for R-38 insulation in attic, Plans show vented attic, Attic space is unvented with foam insulation dirrectly applied to the roof deck, and unsulation certification on site shows R-20. 2. Need shcedule 40 cap on DWV for future sink in garage…. P3005.1.5 (per home owner the sink cabinet is on extended back order, sink is shown on plans)
ROW FIELD SURVEY /GRADING CERTIFICATION 02/02/2023 APPROVED GBERTOLA
Note: 02/2/23= AT THE TIME OF THE INSPECTION EVERYTHING LOOK GOOD
ROW - FINAL INSPECTION 02/02/2023 APPROVED GBERTOLA
Note: AT THE TIME OF THE INSPECTION EVERYTHING LOOK GOOD
U -UTILITY RESIDENTIAL FINAL 02/02/2023 FINAL APPROVED JHARDING
ROW- FINAL SURVEY/GRADING CERTIFICATION 02/01/2023 APPROVED - AS NOTED PFLANAGAN
Note: AFTER FURTHER REVIEW THE SOD ELEVATIONS WAS BELOW THE FFE THE RIGHT AMOUNT PLEASE CONTACT PARREN FOR ANY QUESTIONS -------------------------------------------------------------------------- 1/24/2023 - PREVIOUS INSPECTION NOTES SOD ELEVATIONS UP AGAINST THE STRUCTURE NEEDS TO BE 4" BELOW THE FEE ON A CONCRETE STRUCTURE AND 6" BELOW THE FFE OF A WOOD FRAME STRUCTURE.
ROW- FINAL SURVEY/GRADING CERTIFICATION 01/24/2023 Disapproved - NO FEE PFLANAGAN
Note: SOD ELEVATIONS UP AGAINST THE STRUCTURE NEEDS TO BE 4" BELOW THE FEE ON A CONCRETE STRUCTURE AND 6" BELOW THE FFE OF A WOOD FRAME STRUCTURE.
U - SEWER TIE IN 12/27/2022 APPROVED MGIBSON
GRAVITY SEWER TEST 12/27/2022 APPROVED MGIBSON
Note: Inspector Notes from Inspection 2060 PROVIDE PORTABLE RESTROOM BEFORE SHEDULING MONOLITHIC SLAB INSPECTION
ELECTRIC - EARLY POWER 12/01/2022 APPROVED BTAYLOR
LATH/BRICK/ WATER BARRIER 09/26/2022 APPROVED BTAYLOR
Note: 9/22/2022 - PREVIOUS INSPECTION NOTES
INSULATION 09/26/2022 APPROVED BTAYLOR
Note: 9/22/2022 - PREVIOUS INSPECTION NOTES 9/21/2022 - PREVIOUS INSPECTION NOTES 9/20/2022 - PREVIOUS INSPECTION NOTES 9-20-22 1. Holes in garage wall need fire foam.(Small space with bat pulled down.) 2. Fridge wire needs fire foam. 3. Need fire blocking and fire foam above slider in back room. 9-21-22 1. Need fire blocking and fire foam above slider in back room.
LATH/BRICK/ WATER BARRIER 09/22/2022 CANCELLED BY APPLICANT BTAYLOR
INSULATION 09/22/2022 CANCELLED BY APPLICANT BTAYLOR
Note: 9/21/2022 - PREVIOUS INSPECTION NOTES 9/20/2022 - PREVIOUS INSPECTION NOTES 9-20-22 1. Holes in garage wall need fire foam.(Small space with bat pulled down.) 2. Fridge wire needs fire foam. 3. Need fire blocking and fire foam above slider in back room. 9-21-22 1. Need fire blocking and fire foam above slider in back room.
INSULATION 09/21/2022 Disapproved - NO FEE BTAYLOR
Note: 9/20/2022 - PREVIOUS INSPECTION NOTES 9-20-22 1. Holes in garage wall need fire foam.(Small space with bat pulled down.) 2. Fridge wire needs fire foam. 3. Need fire blocking and fire foam above slider in back room. 9-21-22 1. Need fire blocking and fire foam above slider in back room.
INSULATION 09/20/2022 Disapproved - NO FEE BTAYLOR
Note: 9-20-22 1. Holes in garage wall need fire foam.(Small space with bat pulled down.) 2. Fridge wire needs fire foam. 3. Need fire blocking and fire foam above slider in back room.
ALL ROUGH 09/14/2022 APPROVED BTAYLOR
Note: Inspector Notes from Inspection 2460 THIS IS A REINSPECTION 9-13-22 1. Need strap on triple in breeze way both sides. 2. Need strap on rafter above pool equipment in breeze way.
ROOF SHEATHING / BRACES/TIES/DOWN CELL 09/13/2022 APPROVED - AS NOTED BTAYLOR
Note: THIS IS A REINSPECTION 9-13-22 1. Need strap on triple in breeze way both sides. 2. Need strap on rafter above pool equipment in breeze way.
ROOF SHEATHING / BRACES/TIES/DOWN CELL 09/09/2022 CANCELLED BY APPLICANT BTAYLOR
ROOF VALLEY & METAL 08/19/2022 APPROVED BTAYLOR
ROOF SHEATHING 08/15/2022 APPROVED DCUSHING
TIE BEAM / LINTEL 07/08/2022 APPROVED TSTAUFFACHER
Note: THIS IS A REINSPECTION Plans incomplete/out of order/not all pages approved Tie in to existing house detail not provided Tie into house not exposed for inspection
TIE BEAM / LINTEL 06/24/2022 Disapproved - NO FEE TSTAUFFACHER
Note: Plans incomplete/out of order/not all pages approved Tie in to existing house detail not provided Tie into house not exposed for inspection
FOUND SURVEY APPROVED (OFFICE) 06/24/2022 APPROVED TBAKER
MONOLITHIC SLAB 05/06/2022 APPROVED - AS NOTED DCUSHING
Note: mono slab and column pads @ breezeway
PLUMBING 1ST ROUGH UNDERGROUND 04/05/2022 APPROVED - AS NOTED MGIBSON
Note: PROVIDE PORTABLE RESTROOM BEFORE SHEDULING MONOLITHIC SLAB INSPECTION

Review History

Department Status Date In Date Out
MECH HOLD 02/06/2023 02/06/2023
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Provide heatload and duct layout
MECH COMPLETE 02/06/2023 02/06/2023
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
ZON COMPLETE 11/16/2022 11/16/2022
Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM
ZON HOLD 11/15/2022 11/16/2022
Note: Held By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM Scanned copy is hard to read what is written where you whited out the piece that isn't allowed but it looks like it shows concrete and that would be a patio and still connected to the driveway making it part of the driveway. This is not allowed. Driveways must lead to a garage.
ZON HOLD 11/07/2022 11/07/2022
Note: Held By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM Proposed site plan doesn't match landscape plan. You are showing on the landscape plan a car parked passed the garage entry. This is not allowed. Driveways must lead to a garage.
ENGIN1 COMPLETE 11/07/2022 11/07/2022
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
SW1 COMPLETE 11/07/2022 11/15/2022
Note: Released By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM
ZON HOLD 10/31/2022 11/01/2022
Note: Held By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM Proposed site plan doesn't match landscape plan. Driveway at the widest point cannot exceed 36ft maximum for a two car garage. The way you have it they are still connected which exceeds what is allowed. The patio and driveway cannot be connected. There must be a seperation. Please provide dimensions and make sure once approved the landscape plan must match your proposed approved site plan.
ENGIN1 COMPLETE 10/31/2022 10/31/2022
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
SW1 COMPLETE 10/31/2022 11/04/2022
Note: Released By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM
ZON HOLD 10/24/2022 10/25/2022
Note: Held By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM Proposed site plan doesn't match landscape plan. Driveway at the widest point cannot exceed 36ft maximum for a two car garage.
ZON HOLD 10/19/2022 10/19/2022
Note: Held By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM Landscape plan driveway layout doesn't match the proposed approved site plan There must be a total of 8 trees. Please show all existing and what is being added
BLD COMPLETE 06/30/2022 07/05/2022
Note: Released By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM
ENGIN1 COMPLETE 06/24/2022 06/24/2022
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
ZON COMPLETE 06/24/2022 06/24/2022
Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM
BLD COMPLETE 05/09/2022 05/09/2022
Note: Released By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM
BLD HOLD 04/25/2022 04/26/2022
Note: Held By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM All comments below per the 2020 Florida Building Code – Residential REVIEW COMMENTS: 1. Multiple Span tales and methods have been submitted. Provide if the Engineered or Prescriptive Method is to be used. FBC [A]107. 2. Option #2, 2x4 SP, Total Span of 2x6 is noted for 2x4 span. Revise to reflect the correct span. FBC [A]107.
BLD HOLD 03/30/2022 03/31/2022
Note: Held By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM All comments below per the 2020 Florida Building Code REVIEW COMMENTS: 1. Proposed 2 x 10 rafters appear over spanned per the 2018 Wood Frame Construction Manual. A revision is required. FC 107 2. Provide sizes of proposed wood headers that being installed in place of the precast concrete lintels.
BLD COMPLETE 03/23/2022 03/24/2022
Note: Released By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM
BADMIN COMPLETE 02/10/2022 02/10/2022
Note: Released By: LIBBY MUSGROVE - - LMUSGROVE@PALMCOASTGOV.COM
ELEC COMPLETE 02/10/2022 02/10/2022
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
BLD COMPLETE 02/10/2022 02/10/2022
Note: Released By: FRED REODICA - (386)986-4734 - FREODICA@PALMCOASTGOV.COM Correction for zoning on sheet 1 of 2 re. stucco band on left side elevation. Building review - NA.
BADMIN INFORMATION 02/09/2022 02/09/2022
Note: Held By: BARBIE BEMBRY - (386)986-3780 - BUILDINGDIVISION@PALMCOASTGOV.COM This permit was created/started manually. Until the permit is issued, the same process must be followed. We do not allow for electronic/manual submissions to mix.
ELEC HOLD 02/03/2022 02/04/2022
Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. Can lights in garage need to be fire rated submit spec on can lights. FRC 2020 302.5.3 2. Submit load calcs with the new square footage and the size of the existing service. NEC 2017 220.83
ZON COMPLETE 02/03/2022 02/04/2022
Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM
SW1 COMPLETE 02/03/2022 02/09/2022
Note: Released By: PARREN FLANAGAN - - PFLANAGAN@PALMCOASTGOV.COM
BLD HOLD 02/03/2022 02/09/2022
Note: Held By: FRED REODICA - (386)986-4734 - FREODICA@PALMCOASTGOV.COM Correction: Submited Sheet 1 of 2 ( Elevation views) dated 2/3/2022 appears exactly the same as Original Elevation Views. Please identify the change(s) made for clarity per FBC 7th Ed. Sec. 107.3.
ZON HOLD 01/25/2022 01/27/2022
Note: Held By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM Completing paperwork for the agreement. Once termination of easement agreement is completed we will email for owners signature and notary. Original must be turned into to us for recording. Please provide setbacks from addition to property lines on site plan/survey. Please show on landscape plan the four required trees. Whether existing or adding them please note them on landscape plan for review. Banding must wrap corners at least two feet Garage depth cannot exceed 30ft max Garage space cannot exceed 50% of the living square footage. With addition and house total is 2918. Per the proposed plans and what is existing garage space totals 1486 which is 27ft over. Per the calculations garage space can only total 1459. Please have owners complete a Single family Dwelling Affidavit and turn original in to us for recording
BLD COMPLETE 01/25/2022 01/26/2022
Note: Released By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM
ELEC HOLD 01/25/2022 01/26/2022
Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. Can lights in garage need to be fire rated submit spec on can lights. FBC 2020 714 2. Outlets in screen room, garage, bathroom, outside , and bar area need to be GFCI protected. NEC 207 210.8 3. Need outlets on bar countertop NEC 2017 210.52 (C). 4. Submit load calcs with the new square footage and the size of the existing service. NEC 2017 220.83
MECH COMPLETE 01/25/2022 01/26/2022
Note: Released By: CHRIS PISCITELLI - (386)986-3782 - CPISCITELLI@PALMCOASTGOV.COM
PLUM COMPLETE 01/25/2022 01/26/2022
Note: Released By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM
SW1 COMPLETE 01/25/2022 02/01/2022
Note: Released By: PARREN FLANAGAN - - PFLANAGAN@PALMCOASTGOV.COM

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
PLAN REVIEW - REVISION ¤32.50 02/02/2023
PLAN REVIEW - REVISION ¤32.50 02/02/2023
PLAN REVIEW - REVISION ¤32.50 02/02/2023
RECORDING FEE REIMBURSE DOC ¤35.50 03/01/2022
RECORDING FEE REIMBURSE DOC ¤10.00 03/01/2022
SURCHARGE FS 533.721 ¤7.39 03/01/2022
SURCHARGE - FS 468.631 ¤11.08 03/01/2022
SW ENG - INSPECTION 20 ¤20.00 03/01/2022
SW ENG - REVIEW 20 ¤20.00 03/01/2022
SITE PLAN 30 ¤30.00 03/01/2022
ADMINISTRATIVE RESIDENTIAL ¤30.00 03/01/2022
INSPECTION - RESIDENTIAL ¤514.25 03/01/2022
PLAN REVIEW - RESIDENTIAL ¤145.86 03/01/2022
Fees Total Due: ¤0.00 Total Paid: ¤921.58