I want to search for...

Permit #2022011238

Permit Details

Status: COED

Parcel Id: 07-11-31-7065-00400-0060
CONDITIONED SPACE: 2000 sqft
GARAGE: 476 sqft
OPENED PORCH (WITH ROOF) : 197 sqft
OPENED PORCH (WITH ROOF) : 144 sqft
Total Square Footage: 2817 sqft
Block: 00400
Subdivision: -
Job Phone: 321-501-4617
Location Address: 53 KATHLEEN TR
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 03/11/2022
NOC: RECORDED
Applicant name: JAMES FUCETOLA III
Owner: PALM COAST COMMUNTIES LLC

Address

PO BOX 22547

ST SIMONS ISLAND, GA 31522

Lot: 0060
Contracted Stated Job Value: ¤195,000.00
Job Description: Single Family Residence
Type: CN

Contractor

PALM COAST COMMUNITIES LLC
Status Location Address State License Number Phone
INACTIVE

PO BOX 22547

PALM COAST, FL 32164

CBC1262878 (Exp: 08/31/2026) 321-501-4617

Sub Contractors

JEFFREY TROY SABAKA
Status Location Address State License Number Phone Fax
ACTIVE

2191 DEERWOOD ACRES DR

ST AUGUSTINE, FL 32084

CFC1427439 (Exp: 08/31/2026) 904-838-2218 904-819-0965
GARY LLOYD SHEFFIELD
Status Location Address State License Number Phone
ACTIVE

48 EAGLE LAKES DRIVE

FLAGLER BEACH, FL 32136

CAC048127 (Exp: 08/31/2026) 386-597-3280
WILLIAM FRANK DUDLEY JR.
Status Location Address State License Number Phone
ACTIVE

P.O. BOX 978

Bunnell, FL 32110

EC0003177 (Exp: 08/31/2026) (386)437-3068
OLEG BELINSKIY
Status Location Address State License Number Phone
ACTIVE

19 PINE CIRCLE DRIVE19

PALM COAST, FL 32167

CCC1325974 (Exp: 08/31/2026) 386-263-7906

Inspection History

Type Request Date Result Inspector
BLD - BUILDING FINAL 02/09/2023 FINAL APPROVED TSTAUFFACHER
U -UTILITY RESIDENTIAL FINAL 02/09/2023 FINAL APPROVED JHARDING
ROW - FINAL APRON (AFTER POUR) 02/08/2023 FINAL APPROVED EMADISON
ROW- FINAL SURVEY/GRADING CERTIFICATION 02/08/2023 APPROVED EMADISON
Note: **02/08/23 CORRECTIONS MADE ______________________________________________________________________________________________________________________ 2/2/2023 - PREVIOUS INSPECTION NOTES 02/02/23 A SOD ELEVATIONS NEXT THE STRUCTURE NEED TO BE A MINIMUM OF 4" BELOW FFE NO CHANGES MADE SINCE LAST FINAL SURVEY INSPECTION ___________________________________________________________________________________________________________________________ 1/27/2023 - PREVIOUS INSPECTION NOTES A SOD ELEVATIONS NEXT THE STRUCTURE NEED TO BE A MINIMUM OF 4" BELOW FFE
ROW FIELD SURVEY /GRADING CERTIFICATION 02/08/2023 APPROVED EMADISON
ROW - STORMWATER FINAL 02/08/2023 FINAL APPROVED EMADISON
ROW- FINAL SURVEY/GRADING CERTIFICATION 02/02/2023 Disapproved - NO FEE EMADISON
Note: 02/02/23 A SOD ELEVATIONS NEXT THE STRUCTURE NEED TO BE A MINIMUM OF 4" BELOW FFE NO CHANGES MADE SINCE LAST FINAL SURVEY INSPECTION ___________________________________________________________________________________________________________________________ 1/27/2023 - PREVIOUS INSPECTION NOTES A SOD ELEVATIONS NEXT THE STRUCTURE NEED TO BE A MINIMUM OF 4" BELOW FFE
ROW FIELD SURVEY /GRADING CERTIFICATION 02/02/2023 CANCELLED BY INSPECTOR EMADISON
Note: ** 02/02/23 THIS INSPECTION IS DONE AFTER THE FINAL SURVEY IS PASSED _____________________________________________________________________________________________________________________________ 1/12/2023 - PREVIOUS INSPECTION NOTES THIS INSPECTION IS DONE AFTER THE FINAL SURVEY IS PASSED
ROW- FINAL SURVEY/GRADING CERTIFICATION 01/27/2023 Disapproved - NO FEE PFLANAGAN
Note: A SOD ELEVATIONS NEXT THE STRUCTURE NEED TO BE A MINIMUM OF 4" BELOW FFE
ROW FIELD SURVEY /GRADING CERTIFICATION 01/12/2023 Disapproved - NO FEE PFLANAGAN
Note: THIS INSPECTION IS DONE AFTER THE FINAL SURVEY IS PASSED
U-CROSS CONNECTION 01/12/2023 APPROVED - AS NOTED JHARDING
Note: No cross connections.
ELECTRIC - EARLY POWER 12/19/2022 APPROVED RSIMS
ROW- PRE-APRON (PRE-POUR) 12/06/2022 APPROVED PFLANAGAN
Note: IT'S THE CONTRACTORS RESPONSIBILITY TO CHECK THE CULVERT PIPE ELEVATIONS BEFORE POURING THE CONCRETE FOR THE DRIVEWAY
U - SEWER TIE IN 12/06/2022 APPROVED - AS NOTED MGIBSON
Note: THIS WAS A VIRTUAL INSPECTION
PEP TANK INSTALLATION REQUEST 11/16/2022 APPROVED CSTONE
INSULATION 11/14/2022 APPROVED BTAYLOR
ALL ROUGH 10/19/2022 APPROVED DCUSHING
ROOF SHEATHING / BRACES/TIES/DOWN CELL 10/18/2022 APPROVED RSIMS
Note: 10/17/2022 - PREVIOUS INSPECTION NOTES 10/17/2022: CANCELLED VIA TEXT AT @ 08:58. 10/12/2022 - PREVIOUS INSPECTION NOTES 10/12/2022 - INSPECTION STOPPED Conventional framing missing collar ties as indicated on detail. Cannot verify 2"x8" bottom plate due to stucco covering it. AHU platform still not framed per details on print page 6. 10/11/2022 - PREVIOUS INSPECTION NOTES 10/4/2022 - PREVIOUS INSPECTION NOTES 10/04/2022: PREVIOUS INSPECTION NOTES NOT COMPLETE / INSPECTION STOPPED THIS IS A REINSPECTION 08/31/2022: INCOMPLETE INSPECTION/INSPECTION STOPPED 1. Gable ends missing bracing per Mitek engineering 2.Unable to determine door buck and window buck attachment due to windows and doors installed 3. Conventional framing not per details on pg/5/6- 2x8 nailed to trusses below missing clip from rafters to ridge 4. AC platform not built per plans pg 6/6 5. Front double girder short on mails for appropriate bonding per Mitek 6. No tie down specifics for multi-ply girder attachment to CMU wall INSPECTION STOPPED--TRUSS ENGINEERING NOT INSPECTED 10-11-22 1. Conventional framing not per details on pg/5/6- 2x8 nailed to trusses below missing clip from rafters to ridge 2. Missing H2.5's on rafters to ridge and sleepers Engineering completed.
ROOF SHEATHING / BRACES/TIES/DOWN CELL 10/17/2022 CANCELLED BY APPLICANT RSIMS
Note: 10/17/2022: CANCELLED VIA TEXT AT @ 08:58. 10/12/2022 - PREVIOUS INSPECTION NOTES 10/12/2022 - INSPECTION STOPPED Conventional framing missing collar ties as indicated on detail. Cannot verify 2"x8" bottom plate due to stucco covering it. AHU platform still not framed per details on print page 6. 10/11/2022 - PREVIOUS INSPECTION NOTES 10/4/2022 - PREVIOUS INSPECTION NOTES 10/04/2022: PREVIOUS INSPECTION NOTES NOT COMPLETE / INSPECTION STOPPED THIS IS A REINSPECTION 08/31/2022: INCOMPLETE INSPECTION/INSPECTION STOPPED 1. Gable ends missing bracing per Mitek engineering 2.Unable to determine door buck and window buck attachment due to windows and doors installed 3. Conventional framing not per details on pg/5/6- 2x8 nailed to trusses below missing clip from rafters to ridge 4. AC platform not built per plans pg 6/6 5. Front double girder short on mails for appropriate bonding per Mitek 6. No tie down specifics for multi-ply girder attachment to CMU wall INSPECTION STOPPED--TRUSS ENGINEERING NOT INSPECTED 10-11-22 1. Conventional framing not per details on pg/5/6- 2x8 nailed to trusses below missing clip from rafters to ridge 2. Missing H2.5's on rafters to ridge and sleepers Engineering completed.
ROOF SHEATHING / BRACES/TIES/DOWN CELL 10/12/2022 Disapproved -FEE REQUIRED RSIMS
Note: 10/12/2022 - INSPECTION STOPPED Conventional framing missing collar ties as indicated on detail. Cannot verify 2"x8" bottom plate due to stucco covering it. AHU platform still not framed per details on print page 6. 10/11/2022 - PREVIOUS INSPECTION NOTES 10/4/2022 - PREVIOUS INSPECTION NOTES 10/04/2022: PREVIOUS INSPECTION NOTES NOT COMPLETE / INSPECTION STOPPED THIS IS A REINSPECTION 08/31/2022: INCOMPLETE INSPECTION/INSPECTION STOPPED 1. Gable ends missing bracing per Mitek engineering 2.Unable to determine door buck and window buck attachment due to windows and doors installed 3. Conventional framing not per details on pg/5/6- 2x8 nailed to trusses below missing clip from rafters to ridge 4. AC platform not built per plans pg 6/6 5. Front double girder short on mails for appropriate bonding per Mitek 6. No tie down specifics for multi-ply girder attachment to CMU wall INSPECTION STOPPED--TRUSS ENGINEERING NOT INSPECTED 10-11-22 1. Conventional framing not per details on pg/5/6- 2x8 nailed to trusses below missing clip from rafters to ridge 2. Missing H2.5's on rafters to ridge and sleepers Engineering completed.
ROOF SHEATHING / BRACES/TIES/DOWN CELL 10/11/2022 Disapproved - NO FEE BTAYLOR
Note: 10/4/2022 - PREVIOUS INSPECTION NOTES 10/04/2022: PREVIOUS INSPECTION NOTES NOT COMPLETE / INSPECTION STOPPED THIS IS A REINSPECTION 08/31/2022: INCOMPLETE INSPECTION/INSPECTION STOPPED 1. Gable ends missing bracing per Mitek engineering 2.Unable to determine door buck and window buck attachment due to windows and doors installed 3. Conventional framing not per details on pg/5/6- 2x8 nailed to trusses below missing clip from rafters to ridge 4. AC platform not built per plans pg 6/6 5. Front double girder short on mails for appropriate bonding per Mitek 6. No tie down specifics for multi-ply girder attachment to CMU wall INSPECTION STOPPED--TRUSS ENGINEERING NOT INSPECTED 10-11-22 1. Conventional framing not per details on pg/5/6- 2x8 nailed to trusses below missing clip from rafters to ridge 2. Missing H2.5's on rafters to ridge and sleepers Engineering completed.
ROOF SHEATHING / BRACES/TIES/DOWN CELL 10/04/2022 Disapproved -FEE REQUIRED RSIMS
Note: 10/04/2022: PREVIOUS INSPECTION NOTES NOT COMPLETE / INSPECTION STOPPED THIS IS A REINSPECTION 08/31/2022: INCOMPLETE INSPECTION/INSPECTION STOPPED 1. Gable ends missing bracing per Mitek engineering 2.Unable to determine door buck and window buck attachment due to windows and doors installed 3. Conventional framing not per details on pg/5/6- 2x8 nailed to trusses below missing clip from rafters to ridge 4. AC platform not built per plans pg 6/6 5. Front double girder short on mails for appropriate bonding per Mitek 6. No tie down specifics for multi-ply girder attachment to CMU wall INSPECTION STOPPED--TRUSS ENGINEERING NOT INSPECTED
ROOF SHEATHING / BRACES/TIES/DOWN CELL 08/31/2022 Disapproved - NO FEE TSTAUFFACHER
Note: 08/31/2022: INCOMPLETE INSPECTION/INSPECTION STOPPED 1. Gable ends missing bracing per Mitek engineering 2.Unable to determine door buck and window buck attachment due to windows and doors installed 3. Conventional framing not per details on pg/5/6- 2x8 nailed to trusses below missing clip from rafters to ridge 4. AC platform not built per plans pg 6/6 5. Front double girder short on mails for appropriate bonding per Mitek 6. No tie down specifics for multi-ply girder attachment to CMU wall INSPECTION STOPPED--TRUSS ENGINEERING NOT INSPECTED
LATH/BRICK/ WATER BARRIER 06/17/2022 APPROVED LMILLER
ROOF VALLEY & METAL 06/10/2022 APPROVED KSANDOE
WALL SHEATHING 06/09/2022 APPROVED TSTAUFFACHER
ROOF SHEATHING 06/02/2022 APPROVED KSANDOE
WALL SHEATHING 06/02/2022 APPROVED KSANDOE
FOUND SURVEY APPROVED (OFFICE) 05/31/2022 APPROVED TBAKER
TIE BEAM / LINTEL 05/16/2022 APPROVED TSTAUFFACHER
MONOLITHIC SLAB 04/18/2022 APPROVED TSTAUFFACHER
PLUMBING 1ST ROUGH UNDERGROUND 04/14/2022 APPROVED TSTAUFFACHER
GRAVITY SEWER TEST 04/14/2022 APPROVED TSTAUFFACHER
WATER METER INSTALLATION REQUEST 03/22/2022 APPROVED CSTONE

Review History

Department Status Date In Date Out
MECH COMPLETE 01/13/2023 01/17/2023
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
ENGIN1 COMPLETE 05/31/2022 05/31/2022
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
ZON COMPLETE 05/31/2022 05/31/2022
Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM
ZON COMPLETE 03/29/2022 03/29/2022
Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM
SW1 COMPLETE 03/29/2022 04/05/2022
Note: Released By: ROBERT GROSS - (386)986-4769 - RGROSS@PALMCOASTGOV.COM
BLD COMPLETE 03/03/2022 03/04/2022
Note: Released By: FRED REODICA - (386)986-4734 - FREODICA@PALMCOASTGOV.COM
BLD HOLD 02/24/2022 02/25/2022
Note: Held By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM All comments below per the 2020 Florida Building Code REVIEW COMMENTS: Second Request 1. Floor plan shows cast crete lintels are being used, if power box lintel would also be used as alternate, provide product approval per F.S.553.842 and Schedule with designation mark and for safe/uplift capacity per FBCR 7th Ed. Sec.608.8.2. If not applicable, delete or cross out.
ZON COMPLETE 02/24/2022 02/24/2022
Note: Released By: CINDY CHIRI-GONCALVES - - CGONCALVES@PALMCOASTGOV.COM
SW1 COMPLETE 02/24/2022 03/02/2022
Note: Released By: KALEN RUTH - (386)566-1273 - KRUTH@PALMCOASTGOV.COM
ENGIN1 COMPLETE 02/24/2022 02/25/2022
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
BLD HOLD 01/27/2022 01/27/2022
Note: Held By: FRED REODICA - (386)986-4734 - FREODICA@PALMCOASTGOV.COM 1. Provide missing engineered truss/roof framing layout that should have been submitted during the permit application. A request on letter head should be submitted for deferred submittal as provided on Ciy's Website. Truss package may be submitted at the job site. 2. Provide Components and Cladding of Pressure Zones per FBC - Residential Figure R301.2(7). 3. Sheet 4 of 6 - Foundation Plan: a. Referenced Mark, 3/F between garage and driveway is incorrect based on footer detail shown on Sheet 5 of 6. Also, provide applicable footer details on foundation plan to include rear porch for clarity per FBC 7th Ed. Sec. 107.3. 4. Floor plan shows cast crete lintels are being used, if power box lintel would also be used as alternate, provide product approval per F.S.553.842 and Schedule with designation mark and for safe/uplift capacity per FBCR 7th Ed. Sec.608.8.2. If not applicable, delete or cross out.
CUSVC COMPLETE 01/27/2022 02/01/2022
Note: Released By: HALEIGH HAND - -
ELEC COMPLETE 01/27/2022 01/31/2022
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
ENGIN1 COMPLETE 01/27/2022 01/27/2022
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
LOCATE COMPLETE 01/27/2022 01/28/2022
Note: Released By: CANDACE STONE - - CSTONE@PALMCOASTGOV.COM
MECH COMPLETE 01/27/2022 01/27/2022
Note: Released By: CHRIS PISCITELLI - (386)986-3782 - CPISCITELLI@PALMCOASTGOV.COM
SW1 HOLD 01/27/2022 02/02/2022
Note: Held By: PARREN FLANAGAN - - PFLANAGAN@PALMCOASTGOV.COM The front property line/right away elevation are to be equal to or greater than the centerline of the road elevation. (I) I.Land Development Code Technical Manual, Section 300, Drawing 300.D, Culvert material and size to be depicted. Typical is 17X13 CMP (L) L.Land Development Code Technical Manual, Section 300, Drawing 300.E, Note 5
ZON HOLD 01/27/2022 01/28/2022
Note: Held By: CINDY CHIRI-GONCALVES - - CGONCALVES@PALMCOASTGOV.COM Banding around Windows and doors Banding is required on windows and doors facing the right of way (right elevation).
SWALE COMPLETE 01/27/2022 04/05/2022
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
PLAN REVIEW - REVISION ¤32.50 02/09/2023
REINSPECTION RESIDENTIAL ¤40.00 02/09/2023
REINSPECTION RESIDENTIAL ¤40.00 02/09/2023
CONNECTION FEES ¤1,077.88 03/11/2022
3% FIRE IMPACT FEE CREDIT (¤11.66) 03/11/2022
IMPACT FEE FIRE ¤388.65 03/11/2022
IMPACT FEE PARKS ¤1,455.13 03/11/2022
IMPACT FEE SCHOOL ¤3,600.00 03/11/2022
IMPACT FEE TRANSPORTATION ¤1,764.00 03/11/2022
WATER -IRRIGATION INSPECTION ¤25.00 03/11/2022
3% PARKS IMPACT FEE CREDIT (¤43.65) 03/11/2022
SURCHARGE FS 533.721 ¤9.85 03/11/2022
SURCHARGE - FS 468.631 ¤14.77 03/11/2022
SW ENG - FOUNDATION SURVEY ¤20.00 03/11/2022
SW ENG INSPECTION 80 ¤80.00 03/11/2022
SW ENG PRE APRON ¤30.00 03/11/2022
SW ENG - REVIEW 20 ¤20.00 03/11/2022
SW ENG RES REVIEW 200 ¤200.00 03/11/2022
3% TRANS IMPACT FEE CREDIT (¤52.92) 03/11/2022
SEWER CREDIT (¤850.00) 03/11/2022
SEWER INSPECTION ¤25.00 03/11/2022
SEWER CAPITAL FACILITY ¤4,939.76 03/11/2022
WATER CAPITAL FACILITY FEE ¤3,626.50 03/11/2022
SITE PLAN 30 ¤30.00 03/11/2022
METER - DEPOSIT ¤60.00 03/11/2022
WATER- TURN ON ¤25.00 03/11/2022
ADMINISTRATIVE RESIDENTIAL ¤30.00 03/11/2022
INSPECTION - RESIDENTIAL ¤701.25 03/11/2022
PLAN REVIEW - RESIDENTIAL ¤198.90 03/11/2022
Fees Total Due: ¤0.00 Total Paid: ¤17,475.96