Permit #2022011382

Permit Details

Status: COED

Parcel Id: 48-11-31-1700-00000-0290
GARAGE: 771 sqft
OPENED PORCH (WITH ROOF) : 417 sqft
OPENED PORCH (WITH ROOF) : 59 sqft
CONDITIONED SPACE: 2937 sqft
GARAGE: 151 sqft
Total Square Footage: 4335 sqft
Block: 00000
Subdivision: 2086 - ESTATES AT GRAND HAVEN PHASE I
Job Phone: 386-445-2012
Location Address: 134 WILLOW OAK WAY
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 02/09/2022
NOC: RECORDED
Applicant name: JOHN NICHOLAS CORDASCI
Owner: SKYWAY BUILDERS, INC.

Address

295 PALM COAST PARKWAY

PALM COAST, FL 32137

Lot: 0290
Contracted Stated Job Value: ¤490,000.00
Job Description: SINGLE FAMILY RESIDENCE
Type: CN

Contractor

SKYWAY BUILDERS INC
Status Location Address State License Number Phone
INACTIVE

PO BOX 354786

PALM COAST, FL 32135

CBC1263769 (Exp: 08/31/2024) 386-445-2012

Sub Contractors

MARK A RUGGIERO
Status Location Address State License Number Phone
INACTIVE

411 6TH STREET

HOLLY HILL , FL 32117

01612 (Exp: 07/23/2023) 386-252-5555
RICHARD GARY WILSON JR
Status Location Address Mailing Address State License Number Phone
ACTIVE

1504 OLD MOODY BLVD

BUNNELL, FL 32110

UNIT 6

BUNNELL, FL 32110

CAC1817645 (Exp: 08/31/2026) 386-586-6290
HEATH EDWARD SANFORD
Status Location Address State License Number Phone
ACTIVE

126 EAST END RD

SAN MATEO, FL 32187

CFC1429896 (Exp: 08/31/2026) 386-871-8823
DANIEL DAVID RUTKOWSKI III
Status Location Address State License Number Phone Fax
ACTIVE

1687 STATE AVENUE

HOLLY HILL, FL 32117

CCC1328639 (Exp: 08/31/2026) 386-290-7490 386-256-0001
CHARLES K DAVIS
Status Location Address State License Number Phone
ACTIVE

3000 E MOODY BLVD BLDG 2

BUNNELL , FL 32110

EC13004270 (Exp: 08/31/2026) 386-931-6614

Inspection History

Type Request Date Result Inspector
BLD - BUILDING FINAL 02/10/2023 FINAL APPROVED BTAYLOR
Note: 2/9/2023 - PREVIOUS INSPECTION NOTES 2-9-2023- 1. Garbage disposal is wired directly to switch needs ground fault plug water area, 2. exposed romex in cabinet by disposal. 3. main kitchen plug for disposal and dishwasher not ground faulted, water area. Stopped Inspection. nspector Notes from Inspection 2490 THIS IS A REINSPECTION All grounds need to be connected (ceiling lights grounds are not connected). NEC 250.148. Check at insulation. Two windows have broken glass. 7-29-22 none of the notes above were checked because the inspection was cancelled by John. I am re listing the notes below... 08-01-2022 - Two windows have broken glass. Issue will be resolved by final as per contractor.
BLD - BUILDING FINAL 02/09/2023 Disapproved - NO FEE JSTEWART
Note: 2-9-2023- 1. Garbage disposal is wired directly to switch needs ground fault plug water area, 2. exposed romex in cabinet by disposal. 3. main kitchen plug for disposal and dishwasher not ground faulted, water area. Stopped Inspection. nspector Notes from Inspection 2490 THIS IS A REINSPECTION All grounds need to be connected (ceiling lights grounds are not connected). NEC 250.148. Check at insulation. Two windows have broken glass. 7-29-22 none of the notes above were checked because the inspection was cancelled by John. I am re listing the notes below... 08-01-2022 - Two windows have broken glass. Issue will be resolved by final as per contractor.
U-CROSS CONNECTION 02/08/2023 APPROVED - AS NOTED LFITZGERALD
Note: has reclaim irrigation-no cross connection
ROW - STORMWATER FINAL 02/08/2023 FINAL APPROVED EMADISON
U -UTILITY RESIDENTIAL FINAL 02/08/2023 APPROVED - AS NOTED LFITZGERALD
Note: please utilize 6inch sewer clean out ,do not need 4inch , also change out 6in cap to a flush mount-photo it to me when completed
ROW - FINAL APRON (AFTER POUR) 02/07/2023 FINAL APPROVED EMADISON
ROW- FINAL SURVEY/GRADING CERTIFICATION 02/07/2023 APPROVED EMADISON
ROW FIELD SURVEY /GRADING CERTIFICATION 02/07/2023 APPROVED EMADISON
GAS FINAL 02/06/2023 APPROVED MGIBSON
ROW- PRE-APRON (PRE-POUR) 12/22/2022 APPROVED GBERTOLA
Note: 12/20/2022 - P12/22/22= CORRECTION WERE MADE REVIOUS INSPECTION NOTES THE AREA THAT IS FRONT OF THE HOUSE TO THE LEFT IS NOT ON THE SITE PLAN. ALSO THE PAVER RESTRAINTS DONT GO THAT WAY NEED. TO HAVE A PAVER RESTRAINTS AND THE SITE PLAN REVISED BEFORE MOVING FORWARD WITH THE DRIVEWAY. ------------------------------------------------------------------------------------------- 12/6/2022 - PREVIOUS INSPECTION NOTES READY TO POUR THE 1) PAVER RESTRTAINTS 2) SIDEWALK 3) THE APRON WITH CONCRETE ONLY. BEFORE THE NEXT PRE POUR ALL PAVER BASE NEEDS TO BE SPREAD AND COMPACTED WITH NO PAVERS LAID AT THE TIME OF THE NEXT INSPECTION.
ROW- PRE-APRON (PRE-POUR) 12/20/2022 Disapproved -FEE REQUIRED PFLANAGAN
Note: THE AREA THAT IS FRONT OF THE HOUSE TO THE LEFT IS NOT ON THE SITE PLAN. ALSO THE PAVER RESTRAINTS DONT GO THAT WAY NEED. TO HAVE A PAVER RESTRAINTS AND THE SITE PLAN REVISED BEFORE MOVING FORWARD WITH THE DRIVEWAY. ------------------------------------------------------------------------------------------- 12/6/2022 - PREVIOUS INSPECTION NOTES READY TO POUR THE 1) PAVER RESTRTAINTS 2) SIDEWALK 3) THE APRON WITH CONCRETE ONLY. BEFORE THE NEXT PRE POUR ALL PAVER BASE NEEDS TO BE SPREAD AND COMPACTED WITH NO PAVERS LAID AT THE TIME OF THE NEXT INSPECTION.
ROW- PAVER RESTRAINTS 12/06/2022 APPROVED PFLANAGAN
Note: READY TO POUR THE 1) PAVER RESTRTAINTS 2) SIDEWALK 3) THE APRON WITH CONCRETE ONLY. BEFORE THE NEXT PRE POUR ALL PAVER BASE NEEDS TO BE SPREAD AND COMPACTED WITH NO PAVERS LAID AT THE TIME OF THE NEXT INSPECTION.
ROW- PRE-APRON (PRE-POUR) 12/06/2022 PARTIALLY APPROVED PFLANAGAN
Note: READY TO POUR THE 1) PAVER RESTRTAINTS 2) SIDEWALK 3) THE APRON WITH CONCRETE ONLY. BEFORE THE NEXT PRE POUR ALL PAVER BASE NEEDS TO BE SPREAD AND COMPACTED WITH NO PAVERS LAID AT THE TIME OF THE NEXT INSPECTION.
ELECTRIC - EARLY POWER 10/05/2022 APPROVED RMARTIN
Note: 10/4/2022 - PREVIOUS INSPECTION NOTES 1. Power outside not safed off, electricans on site working, not ready Stopped inspection
ELECTRIC - EARLY POWER 10/04/2022 Disapproved - NO FEE MKRASKI
Note: 1. Power outside not safed off, electricans on site working, not ready Stopped inspection
GRAVITY SEWER TEST 08/29/2022 APPROVED MGIBSON
U - SEWER TIE IN 08/29/2022 APPROVED MGIBSON
GAS ROUGH 08/04/2022 APPROVED MGIBSON
Note: THIS IS A REINSPECTION NO PRESSURE ON GUAGE ''0''
INSULATION 08/01/2022 APPROVED - AS NOTED AGAETANO
Note: THIS IS A REINSPECTION All grounds need to be connected (ceiling lights grounds are not connected). NEC 250.148. Check at insulation. Two windows have broken glass. 7-29-22 none of the notes above were checked because the inspection was cancelled by John. I am re listing the notes below... 08-01-2022 - Two windows have broken glass. Issue will be resolved by final as per contractor.
INSULATION 07/29/2022 CANCELLED BY APPLICANT LMILLER
Note: All grounds need to be connected (ceiling lights grounds are not connected). NEC 250.148. Check at insulation. Two windows have broken glass. 7-29-22 none of the notes above were checked because the inspection was cancelled by John. I am re listing the notes below... All grounds need to be connected (ceiling lights grounds are not connected). NEC 250.148. Check at insulation. Two windows have broken glass.
LATH/BRICK/ WATER BARRIER 07/21/2022 APPROVED DCUSHING
ALL ROUGH 07/18/2022 APPROVED - AS NOTED AGAETANO
Note: THIS IS A REINSPECTION All grounds need to be connected (ceiling lights grounds are not connected). NEC 250.148. Check at insulation. Two windows have broken glass.
WINDOW NAILING 07/18/2022 APPROVED AGAETANO
Note: Inspector Notes from Inspection 2420 THIS IS A REINSPECTION 07-18-2022 - All grounds need to be connected (ceiling lights grounds are not connected). NEC 250.148. Check at insulation. Two windows have broken glass.
ELECTRIC-TUG 07/11/2022 APPROVED - AS NOTED JMUNSON
Note: Emailed FPL at 10:12 am
WINDOW NAILING 06/22/2022 APPROVED - AS NOTED DCUSHING
Note: Sliding Glass Door only in order to seal up
ALL ROUGH 06/22/2022 CANCELLED BY APPLICANT DCUSHING
WALL SHEATHING 06/17/2022 APPROVED LMILLER
GAS ROUGH 06/17/2022 Disapproved -FEE REQUIRED MGIBSON
Note: NO PRESSURE ON GUAGE ''0''
ROOF SHEATHING / BRACES/TIES/DOWN CELL 05/17/2022 APPROVED LMILLER
Note: THIS IS A REINSPECTION need a detail for knee wall over entry that matches the construction and engineering. Missing SP4 on jack (all highighted on plans) 5-17-22 added strapping meets bearing wall detail
ROOF VALLEY & METAL 05/16/2022 APPROVED LMILLER
ROOF SHEATHING / BRACES/TIES/DOWN CELL 05/16/2022 Disapproved - NO FEE LMILLER
Note: need a detail for knee wall over entry that matches the construction and engineering. Missing SP4 on jack (all highighted on plans)
TIE BEAM / LINTEL 04/06/2022 APPROVED LMILLER
FOUND SURVEY APPROVED (OFFICE) 04/05/2022 APPROVED TBAKER
MONOLITHIC SLAB 03/15/2022 APPROVED AGAETANO
PLUMBING 1ST ROUGH UNDERGROUND 03/14/2022 APPROVED MGIBSON
WATER METER INSTALLATION REQUEST 02/18/2022 APPROVED CSTONE

Review History

Department Status Date In Date Out
ZON COMPLETE 12/21/2022 12/21/2022
Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM
ENGIN1 COMPLETE 12/20/2022 12/21/2022
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
SW1 COMPLETE 12/20/2022 12/28/2022
Note: Released By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM
ZON HOLD 12/20/2022 12/21/2022
Note: Held By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM If you are adding a turnaround it must be 9ft wide by 18ft in length.
BLD COMPLETE 06/22/2022 06/22/2022
Note: Released By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM
ENGIN1 COMPLETE 04/05/2022 04/05/2022
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
ZON COMPLETE 04/05/2022 04/05/2022
Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM
BLD COMPLETE 02/09/2022 02/09/2022
Note: Released By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM
BLD HOLD 02/07/2022 02/09/2022
Note: Held By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM
ELEC COMPLETE 02/07/2022 02/08/2022
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
MECH COMPLETE 02/07/2022 02/08/2022
Note: Released By: CHRIS PISCITELLI - (386)986-3782 - CPISCITELLI@PALMCOASTGOV.COM
PLFM COMPLETE 02/01/2022 02/01/2022
Note: Released By: JORDAN MYERS, C.F.M - (386)986-2320 - JMYERS@PALMCOASTGOV.COM According to the site plan submitted on 1/31/22, the structure will not fall within the special flood hazard area. No elevation certificates will be required.
BLD HOLD 01/31/2022 02/07/2022
Note: Held By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM All comments below per the 2020 Florida Building Code-Residential REVIEW COMMENTS: 1. Product approval for soffit materials and roofing materials are the same. A revision is required to provide the corrected Product Approvals for each. Per F.S. 471.025 and F.A.C. 61 G15-23.005.
CUSVC COMPLETE 01/31/2022 02/07/2022
Note: Released By: HALEIGH HAND - -
ELEC HOLD 01/31/2022 01/31/2022
Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM Outdoor garden outlet needs to be GFCI protected. NEC 2017 210.8
ENGIN1 COMPLETE 01/31/2022 01/31/2022
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
LOCATE COMPLETE 01/31/2022 02/03/2022
Note: Released By: CANDACE STONE - - CSTONE@PALMCOASTGOV.COM
MECH HOLD 01/31/2022 01/31/2022
Note: Held By: CHRIS PISCITELLI - (386)986-3782 - CPISCITELLI@PALMCOASTGOV.COM Equipment Model numbers and AHRI number need to be on manual J summary page
SW1 COMPLETE 01/31/2022 02/07/2022
Note: Released By: PARREN FLANAGAN - - PFLANAGAN@PALMCOASTGOV.COM
ZON COMPLETE 01/31/2022 02/01/2022
Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
CONTRACTOR CHANGE ¤40.00 02/10/2023
SW ENG REINSPECTION 30 ¤30.00 02/10/2023
PLAN REVIEW - REVISION ¤32.50 02/10/2023
REINSPECTION RESIDENTIAL ¤40.00 02/10/2023
CONNECTION FEES ¤25.00 02/09/2022
SW ENG - REVIEW 20 ¤20.00 02/09/2022
SW ENG RES REVIEW 200 ¤200.00 02/09/2022
3% TRANS IMPACT FEE CREDIT (¤96.72) 02/09/2022
SEWER INSPECTION ¤25.00 02/09/2022
SITE PLAN 30 ¤30.00 02/09/2022
METER - DEPOSIT ¤60.00 02/09/2022
WATER-METER ¤467.09 02/09/2022
WATER-METER ¤388.04 02/09/2022
ADMINISTRATIVE RESIDENTIAL ¤30.00 02/09/2022
INSPECTION - RESIDENTIAL ¤1,347.50 02/09/2022
PLAN REVIEW - RESIDENTIAL ¤382.20 02/09/2022
3% FIRE IMPACT FEE CREDIT (¤11.66) 02/09/2022
IMPACT FEE FIRE ¤388.65 02/09/2022
IMPACT FEE PARKS ¤1,455.13 02/09/2022
IMPACT FEE SCHOOL ¤3,600.00 02/09/2022
IMPACT FEE TRANSPORTATION ¤3,224.00 02/09/2022
3% PARKS IMPACT FEE CREDIT (¤43.65) 02/09/2022
SURCHARGE FS 533.721 ¤18.36 02/09/2022
SURCHARGE - FS 468.631 ¤27.53 02/09/2022
SW ENG - FOUNDATION SURVEY ¤20.00 02/09/2022
SW ENG INSPECTION 80 ¤80.00 02/09/2022
SW ENG PRE APRON ¤30.00 02/09/2022
Fees Total Due: ¤0.00 Total Paid: ¤11,808.97