Permit #2022020677
Permit Details
Status: COED
| Parcel Id: 29-10-31-5540-00000-1620 |
| CONDITIONED SPACE: 3276 sqft |
| GARAGE: 1588 sqft |
| OPENED PORCH (WITH ROOF) : 992 sqft |
| OPENED PORCH (WITH ROOF) : 64 sqft |
| Total Square Footage: 5920 sqft |
| Block: 00000 |
| Subdivision: 1005 - SANCTUARY SUBDIVISION |
| Job Phone: (386)445-9393 |
| Location Address: 15 OLD OAK DR S |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 04/18/2022 |
| NOC: RECORDED |
| Applicant name: ANTONIO JR AMARAL |
| Owner: DIAS EDUARDO M & MARIA G DEJESUS DIAS H&W |
|
Address APT 2 ELIZABETH, NJ 7201 |
|
Address 1000 MADISON AE ELIZABETH, NJ 7201 |
| Lot: 1620 |
| Contracted Stated Job Value: ¤400,000.00 |
| Job Description: SINGLE FAMILY RESIDENCE |
| Type: CN |
Contractor
AMARAL HOMES & POOLS, LLC
| Status | Location Address | State License Number | Phone |
| ACTIVE |
13 Utility Drive PALM COAST, FL 32137 |
CBC058062 (Exp: 08/31/2026) | (386)445-9393 |
Sub Contractors
RICHARD H SIMMONS JR
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
PO BOX 1963 BUNNELL, FL 32110 |
ES12001217 (Exp: 08/31/2026) | 386-437-0607 | 386-437-1847 |
JONATHAN M PEARSON
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
209 N FORSYTH ST BUNNELL, FL 32110 |
CFC1425941 (Exp: 08/31/2026) | 386-597-0944 | 386-437-4996 |
ANTONIO AMARAL JR
| Status | Location Address | State License Number |
| ACTIVE |
1370 PALM HARBOR PKWY PALM COAST, FL 32137 |
CCC058004 (Exp: 08/31/2026) |
GARY LLOYD SHEFFIELD
| Status | Location Address | State License Number | Phone |
| ACTIVE |
48 EAGLE LAKES DRIVE FLAGLER BEACH, FL 32136 |
CAC048127 (Exp: 08/31/2026) | 386-597-3280 |
Inspection History
| Type | Request Date | Result | Inspector |
| DOWN CELL | 07/11/2024 | APPROVED - AS NOTED | PBUCKLEY |
| Note: 5/31/2024 - PREVIOUS INSPECTION NOTES 5/31/24 Retaining wall has been poured. No prints onsite. Please contact the building department for further instructions. 5/23/2024 - PREVIOUS INSPECTION NOTES Please have a full set of approved plans onsite for all inspection. INSPECTION SCHEDULED BY HOMEOWNER. SEE CHRIS P FOR DETAILS. 07/11/24 Inspection administratively approved on receipt of engineer's letter evaluating GPR imagry of wall. | |||
| BLD - BUILDING FINAL | 07/01/2024 | FINAL APPROVED | BTAYLOR |
| Note: 6/28/2024 - PREVIOUS INSPECTION NOTES *** NOTES ADDED BY LMILLER 6/28/2024 12:19:51 PM *** Still working not ready Notes below still need to be resolved 6/27/2024 - PREVIOUS INSPECTION NOTES *** NOTES ADDED BY LMILLER 6/27/2024 3:38:40 PM *** 1. EXTERIOR DOOR LIGHTS…. each exterior door shall have a light and switch R 3903. 2. Duct connection to AHU is leaking on left side. DUCTS MUST BE SEALED: FBC, R-M1601.4.1 CONNECTIONS IN DUCTWORK SHALL BE SECURELY FASTENED AND SEALED | |||
| BLD - BUILDING FINAL | 06/28/2024 | Disapproved - NO FEE | LMILLER |
| Note: *** NOTES ADDED BY LMILLER 6/28/2024 12:19:51 PM *** Still working not ready Notes below still need to be resolved 6/27/2024 - PREVIOUS INSPECTION NOTES *** NOTES ADDED BY LMILLER 6/27/2024 3:38:40 PM *** 1. EXTERIOR DOOR LIGHTS…. each exterior door shall have a light and switch R 3903. 2. Duct connection to AHU is leaking on left side. DUCTS MUST BE SEALED: FBC, R-M1601.4.1 CONNECTIONS IN DUCTWORK SHALL BE SECURELY FASTENED AND SEALED | |||
| BLD - BUILDING FINAL | 06/27/2024 | Disapproved -FEE REQUIRED | LMILLER |
| Note: *** NOTES ADDED BY LMILLER 6/27/2024 3:38:40 PM *** 1. EXTERIOR DOOR LIGHTS…. each exterior door shall have a light and switch R 3903. 2. Duct connection to AHU is leaking on left side. DUCTS MUST BE SEALED: FBC, R-M1601.4.1 CONNECTIONS IN DUCTWORK SHALL BE SECURELY FASTENED AND SEALED | |||
| U-CROSS CONNECTION | 06/27/2024 | APPROVED | DHANEY |
| ROW - FINAL APRON (AFTER POUR) | 06/27/2024 | APPROVED | EMADISON |
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 06/27/2024 | APPROVED | EMADISON |
| ROW FIELD SURVEY /GRADING CERTIFICATION | 06/27/2024 | APPROVED | EMADISON |
| ROW - STORMWATER FINAL | 06/27/2024 | APPROVED | EMADISON |
| U -UTILITY RESIDENTIAL FINAL | 06/27/2024 | FINAL APPROVED | LFITZGERALD |
| DOWN CELL | 05/31/2024 | Disapproved -FEE REQUIRED | JWALKER |
| Note: 5/31/24 Retaining wall has been poured. No prints onsite. Please contact the building department for further instructions. 5/23/2024 - PREVIOUS INSPECTION NOTES Please have a full set of approved plans onsite for all inspection. INSPECTION SCHEDULED BY HOMEOWNER. SEE CHRIS P FOR DETAILS. | |||
| DOWN CELL | 05/23/2024 | Disapproved -FEE REQUIRED | JWALKER |
| Note: Please have a full set of approved plans onsite for all inspection. | |||
| TIE BEAM / LINTEL | 05/23/2024 | CANCELLED BY INSPECTOR | JWALKER |
| Note: This inspection was previously appoved. | |||
| WINDOW NAILING | 05/23/2024 | APPROVED | JWALKER |
| Note: 06-22-2023 Back right lanai door and entry windows not installed. | |||
| FOOTER | 04/30/2024 | APPROVED | AGAETANO |
| ELECTRIC - EARLY POWER | 02/22/2024 | APPROVED | AGAETANO |
| Note: 2/21/2024 - PREVIOUS INSPECTION NOTES 2/20/2024 - PREVIOUS INSPECTION NOTES | |||
| ELECTRIC - EARLY POWER | 02/21/2024 | CANCELLED BY APPLICANT | AGAETANO |
| Note: 2/20/2024 - PREVIOUS INSPECTION NOTES | |||
| ELECTRIC - EARLY POWER | 02/20/2024 | CANCELLED BY APPLICANT | AGAETANO |
| ROW- PRE-APRON (PRE-POUR) | 01/19/2024 | APPROVED - AS NOTED | EMADISON |
| Note: ** 01/19/24 READY TO SET PAVERS _________________________________________________________________________________________________________________ Inspector Notes from Inspection 9271 ** 01/04/24 READY TO POUR APRON AND PAVER RESTRAINTS ** At the time of the inspection all minimum city requirements were met. It is the builders responsibility to ensure that nothing changes after this Inspection is approved. ** Sec.900.04C Residential driveways shall be constructed using material with a minimum of three thousand pounds (3,000 Ibs.) per square inch with Fiber or wire mesh. ** SCHEDULE NEXT PRE-POUR INSPECTION ONCE PAVER BASE HAS BEEN SPREAD AND COMPACTED ** DO NOT SET ANY PAVERS UNTIL THE NEXT PRE-POUR INSPECTION HAS BEEN APPROVED ______________________________________________________________________________________________________________________ 12/19/2023 - PREVIOUS INSPECTION NOTES ** 12/19/23 BUILDERS SITE PLAN SHOWS A CONCRETE DRIVEWAY IF CHANGED TO A PAVER DRIVEWAY BUILDER NEEDS TO PROVIDE THE PAVER DRIVEWAY DETAIL AND CHOOSE WHICH OPTION THEY ARE INSTALLING THE DRIVEWAY AND PAVER RESTRAINTS . ** THIS IS SO THE INSPECTOR KNOWS EXACTLY WHAT OPTION THEY ARE INSPECTING FOR ** THERE WAS NO HARD COPY ISIDE THE BUILDERS PERMIT BOX OF THE PAVER DRIVEWAY DETAIL ** ADDRESS MUST BE POSTED AND PLAINLY VISIBLE TO INSPECTORS. IF ADDRESS IS NOT PLAINLY VISIBLE, INSPECTORS WILL NOT PERFORM INSPECTIONS AND A REINSPECTION FEE WILL BE ISSUED. Florida Building Code-Building Section 501.2 | |||
| ROW- PRE-APRON (PRE-POUR) | 01/04/2024 | PARTIALLY APPROVED | EMADISON |
| Note: ** 01/04/23 READY TO POUR APRON AND PAVER RESTRAINTS ** At the time of the inspection all minimum city requirements were met. It is the builders responsibility to ensure that nothing changes after this Inspection is approved. ** Sec.900.04C Residential driveways shall be constructed using material with a minimum of three thousand pounds (3,000 Ibs.) per square inch with Fiber or wire mesh. ** SCHEDULE NEXT PRE-POUR INSPECTION ONCE PAVER BASE HAS BEEN SPREAD AND COMPACTED ** DO NOT SET ANY PAVERS UNTIL THE NEXT PRE-POUR INSPECTION HAS BEEN APPROVED _______________________________________________________________________________________________________________________ 12/19/2023 - PREVIOUS INSPECTION NOTES ** 12/19/23 BUILDERS SITE PLAN SHOWS A CONCRETE DRIVEWAY IF CHANGED TO A PAVER DRIVEWAY BUILDER NEEDS TO PROVIDE THE PAVER DRIVEWAY DETAIL AND CHOOSE WHICH OPTION THEY ARE INSTALLING THE DRIVEWAY AND PAVER RESTRAINTS . ** THIS IS SO THE INSPECTOR KNOWS EXACTLY WHAT OPTION THEY ARE INSPECTING FOR ** THERE WAS NO HARD COPY ISIDE THE BUILDERS PERMIT BOX OF THE PAVER DRIVEWAY DETAIL ** ADDRESS MUST BE POSTED AND PLAINLY VISIBLE TO INSPECTORS. IF ADDRESS IS NOT PLAINLY VISIBLE, INSPECTORS WILL NOT PERFORM INSPECTIONS AND A REINSPECTION FEE WILL BE ISSUED. Florida Building Code-Building Section 501.2 | |||
| ROW- PAVER RESTRAINTS | 01/04/2024 | APPROVED - AS NOTED | EMADISON |
| Note: ** 01/04/24 READY TO POUR APRON AND PAVER RESTRAINTS ** At the time of the inspection all minimum city requirements were met. It is the builders responsibility to ensure that nothing changes after this Inspection is approved. ** Sec.900.04C Residential driveways shall be constructed using material with a minimum of three thousand pounds (3,000 Ibs.) per square inch with Fiber or wire mesh. ** SCHEDULE NEXT PRE-POUR INSPECTION ONCE PAVER BASE HAS BEEN SPREAD AND COMPACTED ** DO NOT SET ANY PAVERS UNTIL THE NEXT PRE-POUR INSPECTION HAS BEEN APPROVED ______________________________________________________________________________________________________________________ 12/19/2023 - PREVIOUS INSPECTION NOTES ** 12/19/23 BUILDERS SITE PLAN SHOWS A CONCRETE DRIVEWAY IF CHANGED TO A PAVER DRIVEWAY BUILDER NEEDS TO PROVIDE THE PAVER DRIVEWAY DETAIL AND CHOOSE WHICH OPTION THEY ARE INSTALLING THE DRIVEWAY AND PAVER RESTRAINTS . ** THIS IS SO THE INSPECTOR KNOWS EXACTLY WHAT OPTION THEY ARE INSPECTING FOR ** THERE WAS NO HARD COPY ISIDE THE BUILDERS PERMIT BOX OF THE PAVER DRIVEWAY DETAIL ** ADDRESS MUST BE POSTED AND PLAINLY VISIBLE TO INSPECTORS. IF ADDRESS IS NOT PLAINLY VISIBLE, INSPECTORS WILL NOT PERFORM INSPECTIONS AND A REINSPECTION FEE WILL BE ISSUED. Florida Building Code-Building Section 501.2 | |||
| ROW- PAVER RESTRAINTS | 12/19/2023 | Disapproved - NO FEE | EMADISON |
| Note: ** 12/19/23 BUILDERS SITE PLAN SHOWS A CONCRETE DRIVEWAY IF CHANGED TO A PAVER DRIVEWAY BUILDER NEEDS TO PROVIDE THE PAVER DRIVEWAY DETAIL AND CHOOSE WHICH OPTION THEY ARE INSTALLING THE DRIVEWAY AND PAVER RESTRAINTS . ** THIS IS SO THE INSPECTOR KNOWS EXACTLY WHAT OPTION THEY ARE INSPECTING FOR ** THERE WAS NO HARD COPY ISIDE THE BUILDERS PERMIT BOX OF THE PAVER DRIVEWAY DETAIL ** ADDRESS MUST BE POSTED AND PLAINLY VISIBLE TO INSPECTORS. IF ADDRESS IS NOT PLAINLY VISIBLE, INSPECTORS WILL NOT PERFORM INSPECTIONS AND A REINSPECTION FEE WILL BE ISSUED. Florida Building Code-Building Section 501.2 | |||
| ROW- PRE-APRON (PRE-POUR) | 12/19/2023 | Disapproved -FEE REQUIRED | EMADISON |
| Note: ** 12/19/23 BUILDERS SITE PLAN SHOWS A CONCRETE DRIVEWAY IF CHANGED TO A PAVER DRIVEWAY BUILDER NEEDS TO PROVIDE THE PAVER DRIVEWAY DETAIL AND CHOOSE WHICH OPTION THEY ARE INSTALLING THE DRIVEWAY AND PAVER RESTRAINTS . ** THIS IS SO THE INSPECTOR KNOWS EXACTLY WHAT OPTION THEY ARE INSPECTING FOR ** THERE WAS NO HARD COPY ISIDE THE BUILDERS PERMIT BOX OF THE PAVER DRIVEWAY DETAIL **ADDRESS MUST BE POSTED AND PLAINLY VISIBLE TO INSPECTORS. IF ADDRESS IS NOT PLAINLY VISIBLE, INSPECTORS WILL NOT PERFORM INSPECTIONS AND A REINSPECTION FEE WILL BE ISSUED. Florida Building Code-Building Section 501.2 | |||
| U - SEWER TIE IN | 11/07/2023 | APPROVED - AS NOTED | MGIBSON |
| Note: THIS WAS A VIRTUAL INSPECTION | |||
| GRAVITY SEWER TEST | 11/06/2023 | APPROVED - AS NOTED | MGIBSON |
| Note: GRAVITY SEWER APPROVED AND U-SEWER TIE IN TO BE SCHEDUALED 11/7/23 | |||
| LATH/BRICK/ WATER BARRIER | 09/22/2023 | APPROVED | AGAETANO |
| Note: Inspector Notes from Inspection 2490 Inspector Notes from Inspection 2420 06-22-2023 1. Shield plates needed at laundry plumbing drain and bedroom opposite garage at AC line. 2. Entry door not installed. Glass ot installed. Add window nailing. 3. Smoke alarm not installed at master bedroom. 4. Gas permit and riser not listed. Please submit to the building department. 07-19-2023 1. Piece of insulation missing on garage wall next to shower. 2. Gas line under test and bonded. Please pull gas permit. | |||
| ELECTRIC-TUG | 09/18/2023 | Disapproved - NO FEE | AGAETANO |
| Note: 8/17/2023 - PREVIOUS INSPECTION NOTES 08-17-2023 1. Lugs in meter main not rated for double tap connection. 2. 2" schedule 80 PVC riser not installed. 3. Approved drawings not on site. Check for riser diagram is underground. 09-18-2023 1. Electrical drawings indicate a 300 amp CU service. A 400 amp service and aluminum conductors have been installed. Riser diagram does not match what is installed. 2. Please revise to the building department and install as approved. 3. 4/o aluminum used on 400 amp service. NEC 310.15B | |||
| ELECTRIC-TUG | 08/17/2023 | Disapproved - NO FEE | AGAETANO |
| Note: 08-17-2023 1. Lugs in meter main not rated for double tap connection. 2. 2" schedule 80 PVC riser not installed. 3. Approved drawings not on site. Check for riser diagram is underground. | |||
| INSULATION | 07/19/2023 | APPROVED - AS NOTED | AGAETANO |
| Note: Inspector Notes from Inspection 2420 06-22-2023 1. Shield plates needed at laundry plumbing drain and bedroom opposite garage at AC line. 2. Entry door not installed. Glass ot installed. Add window nailing. 3. Smoke alarm not installed at master bedroom. 4. Gas permit and riser not listed. Please submit to the building department. 07-19-2023 1. Piece of insulation missing on garage wall next to shower. 2. Gas line under test and bonded. Please pull gas permit. | |||
| ALL ROUGH | 06/22/2023 | APPROVED - AS NOTED | AGAETANO |
| Note: 06-22-2023 1. Shield plates needed at laundry plumbing drain and bedroom opposite garage at AC line. 2. Entry door not installed. Glass ot installed. Add window nailing. 3. Smoke alarm not installed at master bedroom. 4. Gas permit and riser not listed. Please submit to the building department. | |||
| WALL SHEATHING | 05/09/2023 | APPROVED | AGAETANO |
| ROOF VALLEY & METAL | 05/09/2023 | APPROVED | AGAETANO |
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 03/03/2023 | APPROVED | TSTAUFFACHER |
| Note: 2/13/2023 - PREVIOUS INSPECTION NOTES 02/13/2023-Page 5 details call for h2.5 installed at conventional framing to ridge. Missing in multiple locations 2/10/2023 - PREVIOUS INSPECTION NOTES 02-10-2023 Engineering packet not on site. | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 02/13/2023 | Disapproved - NO FEE | TSTAUFFACHER |
| Note: 02/13/2023-Page 5 details call for h2.5 installed at conventional framing to ridge. Missing in multiple locations 2/10/2023 - PREVIOUS INSPECTION NOTES 02-10-2023 Engineering packet not on site. | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 02/10/2023 | Disapproved - NO FEE | AGAETANO |
| Note: 02-10-2023 Engineering packet not on site. | |||
| TIE BEAM / LINTEL | 11/30/2022 | APPROVED | AGAETANO |
| Note: 11/23/2022 - PREVIOUS INSPECTION NOTES 11-23-2022 Drawings and permit not on site. | |||
| TIE BEAM / LINTEL | 11/23/2022 | Disapproved - NO FEE | AGAETANO |
| Note: 11-23-2022 Drawings and permit not on site. | |||
| FOUND SURVEY APPROVED (OFFICE) | 10/24/2022 | APPROVED | TBAKER |
| MONOLITHIC SLAB | 10/10/2022 | APPROVED | JWALKER |
| Note: 10/5/2022 - PREVIOUS INSPECTION NOTES NEED COMPACTION RESULT POSTED IN BOX | |||
| MONOLITHIC SLAB | 10/05/2022 | Disapproved - NO FEE | RMARTIN |
| Note: NEED COMPACTION RESULT POSTED IN BOX | |||
| WILDLIFE CHECK - ENVIRONMENTAL | 10/04/2022 | APPROVED | JMYERS |
| PLUMBING 1ST ROUGH UNDERGROUND | 09/16/2022 | APPROVED | MGIBSON |
| WATER METER INSTALLATION REQUEST | 07/06/2022 | APPROVED | CSTONE |
Review History
| Department | Status | Date In | Date Out |
| BLD | COMPLETE | 07/08/2024 | 07/11/2024 |
| Note: Released By: PATRICK BUCKLEY - (386)986-3786 - PBUCKLEY@PALMCOASTGOV.COM | |||
| BLD | HOLD | 06/28/2024 | 07/01/2024 |
| Note: Held By: PATRICK BUCKLEY - (386)986-3786 - PBUCKLEY@PALMCOASTGOV.COM Engineer who designed the wall to examine the GPR data and write a letter confirming the imagry depicts reinforcing steel in the locations consistent with his design plans. | |||
| ZON | COMPLETE | 04/15/2024 | 04/16/2024 |
| Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM | |||
| ELEC | COMPLETE | 04/15/2024 | 04/18/2024 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 04/15/2024 | 04/17/2024 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| BLD | HOLD | 04/03/2024 | 04/10/2024 |
| Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Provide wind speed design criteria for wall R301.1 FBC Residential 2020 7th edition | |||
| ELEC | HOLD | 04/03/2024 | 04/08/2024 |
| Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1 Show wire sizes for spa | |||
| ENGIN1 | COMPLETE | 04/03/2024 | 04/04/2024 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| SW1 | COMPLETE | 04/03/2024 | 04/10/2024 |
| Note: Released By: JEFF CREWS - - JCREWS@PALMCOASTGOV.COM | |||
| ZON | HOLD | 04/03/2024 | 04/03/2024 |
| Note: Held By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM Please note on the plans that the proposed 4' wall under the screen enclosure will be finished with stucco and then painted. You just have a note that it would be painted. It needs to have a stucco finish as well. | |||
| ENGIN1 | COMPLETE | 12/27/2023 | 12/28/2023 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 12/27/2023 | 12/27/2023 |
| Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM | |||
| SW1 | COMPLETE | 12/27/2023 | 01/04/2024 |
| Note: Released By: JEFF CREWS - - JCREWS@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 10/17/2023 | 10/17/2023 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| ELEC | COMPLETE | 10/17/2023 | 10/17/2023 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 12/09/2022 | 12/12/2022 |
| Note: Released By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 10/24/2022 | 10/24/2022 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 10/24/2022 | 10/24/2022 |
| Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 03/29/2022 | 03/29/2022 |
| Note: Released By: FRED REODICA - (386)986-4734 - FREODICA@PALMCOASTGOV.COM | |||
| BLD | HOLD | 03/25/2022 | 03/25/2022 |
| Note: Held By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM All comments below per the 2020 Florida Building Code-Residential REVIEW COMMENTS: 1. Product Approval Specification Sheet per F.S. 553.842: A.OK B. Provide product approvals for the proposed wood anchors. | |||
| ZON | COMPLETE | 03/01/2022 | 03/02/2022 |
| Note: Released By: CINDY CHIRI-GONCALVES - - CGONCALVES@PALMCOASTGOV.COM | |||
| BLD | HOLD | 03/01/2022 | 03/02/2022 |
| Note: Held By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM All comments below per the 2020 Florida Building Code-Residential REVIEW COMMENTS: 1. Product Approval Specification Sheet per F.S. 553.842: A.OK B. Provide product approvals for the proposed wood anchors and truss plates. | |||
| PLENV | COMPLETE | 02/14/2022 | 02/14/2022 |
| Note: Released By: JORDAN MYERS, C.F.M - (386)986-2320 - JMYERS@PALMCOASTGOV.COM Staff conducted a site visit on 2/14/22 and found no Gopher Tortoise or their burrows. Staff suggests placing silt fence as soon as possible to prevent tortoise from moving into the lot. | |||
| CUSVC | COMPLETE | 02/11/2022 | 02/23/2022 |
| Note: Released By: ALYSSA ROSCOE - - | |||
| ELEC | COMPLETE | 02/11/2022 | 02/14/2022 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 02/11/2022 | 02/11/2022 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| LOCATE | COMPLETE | 02/11/2022 | 02/15/2022 |
| Note: Released By: CANDACE STONE - - CSTONE@PALMCOASTGOV.COM | |||
| MECH | COMPLETE | 02/11/2022 | 02/14/2022 |
| Note: Released By: CHRIS PISCITELLI - (386)986-3782 - CPISCITELLI@PALMCOASTGOV.COM | |||
| SW1 | COMPLETE | 02/11/2022 | 02/16/2022 |
| Note: Released By: KALEN RUTH - (386)566-1273 - KRUTH@PALMCOASTGOV.COM | |||
| ZON | HOLD | 02/11/2022 | 02/14/2022 |
| Note: Held By: CINDY CHIRI-GONCALVES - - CGONCALVES@PALMCOASTGOV.COM Color sheet was not provided. Please download the correct paperwork. Site plan please provide the width of driveway. | |||
| BLD | HOLD | 02/04/2022 | 02/15/2022 |
| Note: Held By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM All comments below per the 2020 Florida Building Code-Residential REVIEW COMMENTS: 1. Product Approval Specification Sheet per F.S. 553.842: A. FL7849.32 roofing tiles is incorrect and doesn’t match the Roofing Worksheet. B. Provide product approvals for the proposed wood anchors and truss plates. |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| WATER-METER | ¤467.09 | 06/28/2024 |
| WATER- TURN ON | ¤25.00 | 06/28/2024 |
| PLAN REVIEW - REVISION | ¤32.50 | 06/28/2024 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 06/28/2024 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 06/28/2024 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 06/28/2024 |
| CONTRACTOR CHANGE | ¤20.00 | 06/28/2024 |
| WATER -IRRIGATION INSPECTION | ¤25.00 | 06/28/2024 |
| SW ENG REINSPECTION 30 | ¤30.00 | 06/28/2024 |
| SW ENG - REVIEW 20 | ¤20.00 | 04/18/2022 |
| SW ENG RES REVIEW 200 | ¤200.00 | 04/18/2022 |
| 3% TRANS IMPACT FEE CREDIT | (¤96.72) | 04/18/2022 |
| SEWER INSPECTION | ¤25.00 | 04/18/2022 |
| SEWER CAPITAL FACILITY | ¤4,939.76 | 04/18/2022 |
| WATER CAPITAL FACILITY FEE | ¤3,626.50 | 04/18/2022 |
| SITE PLAN 30 | ¤30.00 | 04/18/2022 |
| WATER-METER | ¤467.09 | 04/18/2022 |
| 3% PARKS IMPACT FEE CREDIT | (¤43.65) | 04/18/2022 |
| SURCHARGE FS 533.721 | ¤17.74 | 04/18/2022 |
| SURCHARGE - FS 468.631 | ¤26.61 | 04/18/2022 |
| SW ENG - FOUNDATION SURVEY | ¤20.00 | 04/18/2022 |
| SW ENG INSPECTION 80 | ¤80.00 | 04/18/2022 |
| SW ENG PRE APRON | ¤30.00 | 04/18/2022 |
| 3% FIRE IMPACT FEE CREDIT | (¤11.66) | 04/18/2022 |
| IMPACT FEE FIRE | ¤388.65 | 04/18/2022 |
| IMPACT FEE PARKS | ¤1,455.13 | 04/18/2022 |
| IMPACT FEE SCHOOL | ¤3,600.00 | 04/18/2022 |
| IMPACT FEE TRANSPORTATION | ¤3,224.00 | 04/18/2022 |
| CONNECTION FEES | ¤25.00 | 04/18/2022 |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | 04/18/2022 |
| INSPECTION - RESIDENTIAL | ¤1,300.75 | 04/18/2022 |
| PLAN REVIEW - RESIDENTIAL | ¤368.94 | 04/18/2022 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤20,442.73 |