Permit #2022021407
Permit Details
Status: COED
| Parcel Id: 29-10-31-5540-00000-0020 |
| CONDITIONED SPACE: 3128 sqft |
| GARAGE: 814 sqft |
| OPENED PORCH (WITH ROOF) : 818 sqft |
| Total Square Footage: 4760 sqft |
| Block: 00000 |
| Subdivision: 1005 - SANCTUARY SUBDIVISION |
| Job Phone: (386) 446-5850 |
| Location Address: 6 OLD OAK DR S |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 03/29/2022 |
| NOC: RECORDED |
| Applicant name: CHARLES DALLAS RINEK |
| Owner: BERRY CHRISTOPHER D & JERRY C BERRY AMC |
|
Address 37 COMANCHE COURT PALM COAST, FL 32137 |
| Lot: 0020 |
| Contracted Stated Job Value: ¤650,000.00 |
| Job Description: SINGLE FAMILY RESIDENCE |
| Type: CN |
Contractor
CHARLES RINEK CONSTRUCTION, INC.
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
P. O. Box 352502 Palm Coast, FL 32137 |
CGC046080 (Exp: 08/31/2026) | (386) 446-5850 | (386)445-9992 |
Sub Contractors
JONATHAN M PEARSON
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
209 N FORSYTH ST BUNNELL, FL 32110 |
CFC1425941 (Exp: 08/31/2026) | 386-597-0944 | 386-437-4996 |
ERIC FRANCO
| Status | Location Address | Mailing Address | State License Number | Phone |
| INACTIVE |
840 DELTONA BLVD DELTONA, FL 32725 |
STE F2 DELTONA, FL 32725 |
CCC1327280 (Exp: 08/31/2026) | 386-575-4007 |
SHAWN MICHAEL HISS
| Status | Location Address | State License Number | Phone |
| ACTIVE |
1315 LPGA BLVD HOLLY HILL, FL 32117 |
CAC1813585 (Exp: 08/31/2026) | (386)672-8688 |
DANIEL JOSEPH SCHWARZKOPF
| Status | Location Address | State License Number | Phone |
| ACTIVE |
4601 E MOODY BLVD D6 PALM COAST, FL 32164 |
EC13010351 (Exp: 08/31/2026) | 386-313-6211 |
Inspection History
| Type | Request Date | Result | Inspector |
| BLD - BUILDING FINAL | 11/21/2023 | FINAL APPROVED | AGAETANO |
| Note: 11/20/2023 - PREVIOUS INSPECTION NOTES 11-20-2023 1. Electrical panel not labeled completely. Need to check both panels. 2. Disposal and dishwasher does not work. 3. Disposal drain not tied to underside of the sink. | |||
| BLD - BUILDING FINAL | 11/20/2023 | CANCELLED BY APPLICANT | AGAETANO |
| Note: 11-20-2023 1. Electrical panel not labeled completely. Need to check both panels. 2. DAisposal and dishwasher does not work. 3. Disposal drain not tied to underside of the sink. | |||
| U -UTILITY RESIDENTIAL FINAL | 11/20/2023 | FINAL APPROVED | DHANEY |
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 11/17/2023 | APPROVED | EMADISON |
| Note: 11/15/2023 - PREVIOUS INSPECTION NOTES ** 11/15/23 FINAL SURVEY NEEDS FINAL ELEVATION SHOTS ONLY (NO PROPOSED) **FINAL SURVEY NEEDS TO HAVE ALL ELEVATION SHOTS ON A 20 FT GRID WITHIN AND ALONG PROPERTY LINES. ** 10 FT OFFSET ELEVATION SHOTS ON ALL ADJACENT PROPERTIES ** SHOW FFE OF ALL PATIO SURFACES | |||
| ROW FIELD SURVEY /GRADING CERTIFICATION | 11/17/2023 | APPROVED | EMADISON |
| ROW - STORMWATER FINAL | 11/17/2023 | APPROVED | EMADISON |
| ROW - FINAL APRON (AFTER POUR) | 11/17/2023 | APPROVED | EMADISON |
| GAS FINAL | 11/17/2023 | APPROVED | MGIBSON |
| Note: Inspector Notes from Inspection 2225 -1-18-2023 Please provide manufacturer's specs for gas piping support in ceiling and walls. | |||
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 11/15/2023 | Disapproved - NO FEE | EMADISON |
| Note: ** 11/15/23 FINAL SURVEY NEEDS FINAL ELEVATION SHOTS ONLY (NO PROPOSED) **FINAL SURVEY NEEDS TO HAVE ALL ELEVATION SHOTS ON A 20 FT GRID WITHIN AND ALONG PROPERTY LINES. ** 10 FT OFFSET ELEVATION SHOTS ON ALL ADJACENT PROPERTIES ** SHOW FFE OF ALL PATIO SURFACES | |||
| U-CROSS CONNECTION | 11/15/2023 | APPROVED | DHANEY |
| ROW- PRE-APRON (PRE-POUR) | 08/01/2023 | APPROVED - AS NOTED | EMADISON |
| Note: ** 08/01/23 READY TO SET PAVERS ___________________________________________________________________________________________________________________ 6/9/2023 10:40:57 AM- PREVIOUS INSPECTION NOTES ** 06/09/23 READY TO POUR APRON AND PAVER RESTRAINTS **Sec.900.04C Residential driveways shall be constructed using material with a minimum of three thousand pounds (3,000 Ibs.) per square inch with Fiber or wire mesh. ** SCHEDULE NEXT PRE-POUR INSPECTION ONCE PAVER BASE HAS BEEN SPREAD AND COMPACTED ** DO NOT SET ANY PAVERS UNTIL THE NEXT PRE-POUR INSPECTION HAS BEEN APPROVED _______________________________________________________________________________________________ ** 06/09/23 BUILDER NEEDS TO PROVIDE A RESIDENTIAL PAVER RESTRAINT DETAIL PLAN FOR THE DRIVEWAY | |||
| ELECTRIC - EARLY POWER | 06/28/2023 | CANCELLED BY APPLICANT | WEB |
| Note: 6/27/2023 - PREVIOUS INSPECTION NOTES 6/22/2023 - PREVIOUS INSPECTION NOTES 06-22-2023 Multiple outlets and ceiling lights not safe off. Inspection stopped. 06-27-2023 No inspection, doors locked, need access for inspection. FBC R110.1 | |||
| ELECTRIC - EARLY POWER | 06/27/2023 | APPROVED - AS NOTED | AGAETANO |
| Note: New inspection due to canceled inspection 6/27/2023 - PREVIOUS INSPECTION NOTES 6/22/2023 - PREVIOUS INSPECTION NOTES 06-22-2023 Multiple outlets and ceiling lights not safe off. Inspection stopped. 06-27-2023 FPL notified at 12:43 pm | |||
| ELECTRIC - EARLY POWER | 06/27/2023 | Disapproved -FEE REQUIRED | AGAETANO |
| Note: 6/22/2023 - PREVIOUS INSPECTION NOTES 06-22-2023 Multiple outlets and ceiling lights not safe off. Inspection stopped. 06-27-2023 No inspection, doors locked, need access for inspection. FBC R110.1 | |||
| ELECTRIC - EARLY POWER | 06/22/2023 | Disapproved - NO FEE | AGAETANO |
| Note: 06-22-2023 Multiple outlets, ceiling lights not safe off. Cover plates not installed. Inspection stopped. | |||
| GRAVITY SEWER TEST | 06/12/2023 | APPROVED - AS NOTED | MGIBSON |
| Note: THIS WAS A VIRTUAL INSPECTION | |||
| U - SEWER TIE IN | 06/12/2023 | APPROVED - AS NOTED | MGIBSON |
| Note: THIS WAS A VIRTUAL INSPECTION | |||
| ROW- PAVER RESTRAINTS | 06/09/2023 | APPROVED | EMADISON |
| Note: ** 06/09/23 READY TO POUR APRON AND PAVER RESTRAINTS **Sec.900.04C Residential driveways shall be constructed using material with a minimum of three thousand pounds (3,000 Ibs.) per square inch with Fiber or wire mesh. | |||
| ROW- PRE-APRON (PRE-POUR) | 06/09/2023 | PARTIALLY APPROVED | EMADISON |
| Note: ** 06/09/23 READY TO POUR APRON AND PAVER RESTRAINTS **Sec.900.04C Residential driveways shall be constructed using material with a minimum of three thousand pounds (3,000 Ibs.) per square inch with Fiber or wire mesh. ** SCHEDULE NEXT PRE-POUR INSPECTION ONCE PAVER BASE HAS BEEN SPREAD AND COMPACTED ** DO NOT SET ANY PAVERS UNTIL THE NEXT PRE-POUR INSPECTION HAS BEEN APPROVED _______________________________________________________________________________________________ ** 06/09/23 BUILDER NEEDS TO PROVIDE A RESIDENTIAL PAVER RESTRAINT DETAIL PLAN FOR THE DRIVEWAY | |||
| LATH/BRICK/ WATER BARRIER | 03/13/2023 | APPROVED | TSTAUFFACHER |
| Note: Inspector Notes from Inspection 2490 02-16-2023 Dryer vent is protruding into the laundry room at the ceiling. Superintendent will address prior to drywall being installed. | |||
| INSULATION | 02/16/2023 | APPROVED - AS NOTED | AGAETANO |
| Note: 02-16-2023 Dryer vent is protruding into the laundry room at the ceiling. Superintendent will address prior to drywall being installed. | |||
| ALL ROUGH | 01/26/2023 | APPROVED | AGAETANO |
| Note: 1/18/2023 - PREVIOUS INSPECTION NOTES 1/13/2023 - PREVIOUS INSPECTION NOTES Install LSTA strap at garage door opening header. Trusses GO1 and AO2 missing engineering. Trusses VO4, 6,8,10,12,14 16 are not installed. Contract has installed conventional overframing. Please have engineer povide a revision to the building department for the roof framing change. Check above listed corrections at ALL ROUGH inspection. 01-13-2023 ADDRESS MUST BE POSTED AND PLAINLY VISIBLE TO INSPECTORS. IF ADDRESS IS NOT PLAINLY VISIBLE, INSPECTORS WILL NOT PERFORM INSPECTIONS AND A REINSPECTION FEE WILL BE ISSUED. Florida Building Code-Building Section 501.2. R319.1 Residential R319.1 Address identification. Buildings shall be provided with approved address identification. The address identification shall be legible and placed in a position that is visible from the street or road fronting the property. Address identification characters shall contrast with their background. Address numbers shall be Arabic numbers or alphabetical letters. Numbers shall not be spelled out. Each character shall be not less than 4 inches (102 mm) in height with a stroke width of not less than 0.5 inch (12.7 mm). Where required by the fire code official, address identification shall be provided in additional approved locations to facilitate emergency response. Where access is by means of a private road and the building address cannot be viewed from the public way, a monument, pole or other sign or means shall be used to identify the structure. Address identification shall be maintained. 01-18-2023 1. Service not installed. 2. UFER not visible. 3. Garage water lines need to have shield plates at slab. 4. Front door not installed. SGD glass not installed. Back double door glass not installed. Window nailing will be added. 5. Gas rough and final added. 6. Gas lines. Please provide manufacturer's specs for gas line support. 7. Mechanical drawings not on site. | |||
| ALL ROUGH | 01/18/2023 | Disapproved - NO FEE | AGAETANO |
| Note: 1/13/2023 - PREVIOUS INSPECTION NOTES Install LSTA strap at garage door opening header. Trusses GO1 and AO2 missing engineering. Trusses VO4, 6,8,10,12,14 16 are not installed. Contract has installed conventional overframing. Please have engineer povide a revision to the building department for the roof framing change. Check above listed corrections at ALL ROUGH inspection. 01-13-2023 ADDRESS MUST BE POSTED AND PLAINLY VISIBLE TO INSPECTORS. IF ADDRESS IS NOT PLAINLY VISIBLE, INSPECTORS WILL NOT PERFORM INSPECTIONS AND A REINSPECTION FEE WILL BE ISSUED. Florida Building Code-Building Section 501.2. R319.1 Residential R319.1 Address identification. Buildings shall be provided with approved address identification. The address identification shall be legible and placed in a position that is visible from the street or road fronting the property. Address identification characters shall contrast with their background. Address numbers shall be Arabic numbers or alphabetical letters. Numbers shall not be spelled out. Each character shall be not less than 4 inches (102 mm) in height with a stroke width of not less than 0.5 inch (12.7 mm). Where required by the fire code official, address identification shall be provided in additional approved locations to facilitate emergency response. Where access is by means of a private road and the building address cannot be viewed from the public way, a monument, pole or other sign or means shall be used to identify the structure. Address identification shall be maintained. 01-18-2023 1. Service not installed. 2. UFER not visible. 3. Garage water lines need to have shield plates at slab. 4. Front door not installed. SGD glass not installed. Back double door glass not installed. Window nailing will be added. 5. Gas rough and final added. 6. Gas lines. Please provide manufacrurer's specs for gas line support. 7. Mechanical drawings not on site. | |||
| GAS ROUGH | 01/18/2023 | APPROVED - AS NOTED | AGAETANO |
| Note: -1-18-2023 Please provide manufacturer's specs for gas piping support in ceiling and walls. | |||
| ALL ROUGH | 01/13/2023 | Disapproved -FEE REQUIRED | AGAETANO |
| Note: Install LSTA strap at garage door opening header. Trusses GO1 and AO2 missing engineering. Trusses VO4, 6,8,10,12,14 16 are not installed. Contract has installed conventional overframing. Please have engineer povide a revision to the building department for the roof framing change. Check above listed corrections at ALL ROUGH inspection. 01-13-2023 ADDRESS MUST BE POSTED AND PLAINLY VISIBLE TO INSPECTORS. IF ADDRESS IS NOT PLAINLY VISIBLE, INSPECTORS WILL NOT PERFORM INSPECTIONS AND A REINSPECTION FEE WILL BE ISSUED. Florida Building Code-Building Section 501.2. R319.1 Residential R319.1 Address identification. Buildings shall be provided with approved address identification. The address identification shall be legible and placed in a position that is visible from the street or road fronting the property. Address identification characters shall contrast with their background. Address numbers shall be Arabic numbers or alphabetical letters. Numbers shall not be spelled out. Each character shall be not less than 4 inches (102 mm) in height with a stroke width of not less than 0.5 inch (12.7 mm). Where required by the fire code official, address identification shall be provided in additional approved locations to facilitate emergency response. Where access is by means of a private road and the building address cannot be viewed from the public way, a monument, pole or other sign or means shall be used to identify the structure. Address identification shall be maintained. | |||
| ROOF VALLEY & METAL | 12/02/2022 | APPROVED | AGAETANO |
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 11/08/2022 | APPROVED | AGAETANO |
| Note: Inspector Notes from Inspection 2460 Install LSTA strap at garage door opening header. Trusses GO1 and AO2 missing engineering. Trusses VO4, 6,8,10,12,14 16 are not installed. Contract has installed conventional overframing. Please have engineer povide a revision to the building department for the roof framing change. Check above listed corrections at ALL ROUGH inspection. | |||
| WALL SHEATHING | 10/10/2022 | APPROVED | AGAETANO |
| Note: Inspector Notes from Inspection 2340 Missing down cell. Check at next inspection. Noted on drawings. | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 10/10/2022 | APPROVED - AS NOTED | JWALKER |
| Note: Install LSTA strap at garage door opening header. Trusses GO1 and AO2 missing engineering. Trusses VO4, 6,8,10,12,14 16 are not installed. Contract has installed conventional overframing. Please have engineer povide a revision to the building department for the roof framing change. Check above listed corrections at ALL ROUGH inspection. | |||
| TIE BEAM / LINTEL | 08/22/2022 | APPROVED | AGAETANO |
| TIE BEAM / LINTEL | 08/22/2022 | APPROVED - AS NOTED | AGAETANO |
| Note: Missing down cell. Check at next inspection. Noted on drawings. | |||
| FOUND SURVEY APPROVED (OFFICE) | 07/20/2022 | APPROVED | TBAKER |
| MONOLITHIC SLAB | 06/30/2022 | APPROVED | RMARTIN |
| Note: THIS IS A REINSPECTION 1. Termite bond not posted. TERMITE TREATMENT…R FBC.318 C1816 2. CLEARANCE ON REBAR FROM EARTH 3” FBC R404.1.2.3.7.4 Noted on drawings. 3. SLAB - R 506.1 Minimum slab depth requirements 3 1/2. Noted on drawings. 4. Slab area noted on drawings needs to be tamped. Right side at toilet area. | |||
| MONOLITHIC SLAB | 06/29/2022 | Disapproved - NO FEE | AGAETANO |
| Note: 1. Termite bond not posted. TERMITE TREATMENT…R FBC.318 C1816 2. CLEARANCE ON REBAR FROM EARTH 3” FBC R404.1.2.3.7.4 Noted on drawings. 3. SLAB - R 506.1 Minimum slab depth requirements 3 1/2. Noted on drawings. 4. Slab area noted on drawings needs to be tamped. Right side at toilet area. | |||
| PLUMBING 1ST ROUGH UNDERGROUND | 06/21/2022 | APPROVED | MGIBSON |
| WILDLIFE CHECK - ENVIRONMENTAL | 06/03/2022 | APPROVED | JMYERS |
| WATER METER INSTALLATION REQUEST | 06/02/2022 | APPROVED | CSTONE |
Review History
| Department | Status | Date In | Date Out |
| ELEC | COMPLETE | 11/17/2023 | 11/17/2023 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 11/17/2023 | 11/17/2023 |
| Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM | |||
| ELEC | HOLD | 11/16/2023 | 11/16/2023 |
| Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. Riser diagram needs to show the wire sizes going to the generator. If engineer cant figure it then need to have electrician draw it up. | |||
| ELEC | HOLD | 11/15/2023 | 11/16/2023 |
| Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. Submit manufacture specs of generator 2. Submit a electrical riser diagram for the generator. | |||
| BLD | COMPLETE | 11/01/2023 | 11/02/2023 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| BADMIN | INFORMATION | 09/15/2023 | 09/15/2023 |
| Note: Marked INFORMATION By: BARBIE BEMBRY - (386)986-3780 - BUILDINGDIVISION@PALMCOASTGOV.COM Documents/Files named incorrectly o Please rename your files in accordance with the naming convention outlined in our ‘document requirements’ located on the permit portal page http://docs.palmcoastgov.com/departments/building/online/document-requirements.pdf o It is important that all submittals follow the guidelines for efficient plan review and record retention accuracy. o You may add to your file name AFTER the above naming convention has been met. Examples Document type: Plans File name : Plans Document type: Foundation Survey File name: Foundation Survey Document type: Manufactures Specifications File Name: Pool Alarm Document type: Manufactures Specifications File Name: Generator | |||
| ENGIN1 | COMPLETE | 06/09/2023 | 06/09/2023 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| SW1 | COMPLETE | 06/09/2023 | 06/14/2023 |
| Note: Released By: GABRIEL BERTOLA - (386)986-7660 - GBERTOLA@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 12/15/2022 | 12/16/2022 |
| Note: Released By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 11/04/2022 | 11/07/2022 |
| Note: Released By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM | |||
| BADMIN | INFORMATION | 09/22/2022 | 09/22/2022 |
| Note: Marked INFORMATION By: SCOTT THOMAS - - STHOMAS@PALMCOASTGOV.COM RENAME TO PLANS.PDF | |||
| ENGIN1 | COMPLETE | 07/19/2022 | 07/20/2022 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 07/19/2022 | 07/19/2022 |
| Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 03/24/2022 | 03/24/2022 |
| Note: Released By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM | |||
| ELEC | COMPLETE | 03/24/2022 | 03/25/2022 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 03/24/2022 | 03/24/2022 |
| Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM | |||
| PLFM | COMPLETE | 03/24/2022 | 03/24/2022 |
| Note: Released By: JORDAN MYERS, C.F.M - (386)986-2320 - JMYERS@PALMCOASTGOV.COM No comments | |||
| ENGIN1 | COMPLETE | 03/24/2022 | 03/24/2022 |
| Note: Released By: JOHN HOWARD - - JHOWARD@PALMCOASTGOV.COM | |||
| SW1 | COMPLETE | 03/24/2022 | 03/28/2022 |
| Note: Released By: PARREN FLANAGAN - - PFLANAGAN@PALMCOASTGOV.COM | |||
| ELEC | HOLD | 03/21/2022 | 03/22/2022 |
| Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. Plans submitted are copies of digitally signed and sealed plans. Copies of a digital signature are not accepted. | |||
| ZON | HOLD | 03/21/2022 | 03/22/2022 |
| Note: Held By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM Please submit a new landscape plan showing the correct rear patio layout. | |||
| PLFM | HOLD | 03/21/2022 | 03/22/2022 |
| Note: Held By: JORDAN MYERS, C.F.M - (386)986-2320 - JMYERS@PALMCOASTGOV.COM The Site Plan submitted on 3/18/22 shows the correct flood zones. However, due to the proximity of flood zone to the structure a construction elevation certificate will be required. If that elevation certificate shows the structure outside of the SFHA no further certificates will be required. | |||
| BLD | HOLD | 03/21/2022 | 03/22/2022 |
| Note: Held By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM All comments below per the 2020 Florida Building Code REVIEW COMMENTS: 1. Plans submitted are copies of digitally signed and sealed plans. Copies of a digital signature are not accepted. 2. Plans submitted are unreadable. | |||
| BLD | HOLD | 03/14/2022 | 03/14/2022 |
| Note: Held By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM All comments below per the 2020 Florida Building Code REVIEW COMMENTS: Second Request 1. Provide product approval of truss plates and lintels on specification sheet per F.S. 553.842. | |||
| PLFM | HOLD | 03/14/2022 | 03/14/2022 |
| Note: Held By: JORDAN MYERS, C.F.M - (386)986-2320 - JMYERS@PALMCOASTGOV.COM Site Plan/Survey appear to have call out of Flood Zone AE and Flood Zone A but in the notes say AE and X. Please clarify, and due to proximity of flood zone to the structure a construction elevation certificate will be required. If that elevation certificate shows the structure outside of the SFHA no further certificates will be required. | |||
| MECH | COMPLETE | 03/14/2022 | 03/16/2022 |
| Note: Released By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM | |||
| ELEC | HOLD | 03/14/2022 | 03/14/2022 |
| Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM Need to be able to verify digital signature on plan. FS 471.025 | |||
| ZON | HOLD | 03/14/2022 | 03/14/2022 |
| Note: Held By: CINDY CHIRI-GONCALVES - - CGONCALVES@PALMCOASTGOV.COM repeat comment: Held By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM Site plan/survey and landscape plan rear patio layout does not match plans please take a look at the floor plan reaer doesn't match splan or survey submitted | |||
| BLD | HOLD | 02/25/2022 | 02/25/2022 |
| Note: Held By: FRED REODICA - (386)986-4734 - FREODICA@PALMCOASTGOV.COM Provide product approval of truss plates and lintels on specification sheet per F.S. 553.842. The Number FL 11473 - R5 is for wood connectors but incorrectly placed on truss plates. | |||
| CUSVC | COMPLETE | 02/25/2022 | 03/03/2022 |
| Note: Released By: ALYSSA ROSCOE - - | |||
| ELEC | HOLD | 02/25/2022 | 03/01/2022 |
| Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. Need smoke alarms outside of all bedrooms. FRC 2020 314 , 315 2. Submit electric load calcs and they need o match the riser diagram | |||
| ENGIN1 | COMPLETE | 02/25/2022 | 02/25/2022 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| LOCATE | COMPLETE | 02/25/2022 | 03/01/2022 |
| Note: Released By: CANDACE STONE - - CSTONE@PALMCOASTGOV.COM | |||
| MECH | HOLD | 02/25/2022 | 02/28/2022 |
| Note: Held By: CHRIS PISCITELLI - (386)986-3782 - CPISCITELLI@PALMCOASTGOV.COM Provide duct layout signed by the AC contractor | |||
| SW1 | COMPLETE | 02/25/2022 | 03/03/2022 |
| Note: Released By: KALEN RUTH - (386)566-1273 - KRUTH@PALMCOASTGOV.COM | |||
| ZON | HOLD | 02/25/2022 | 02/25/2022 |
| Note: Held By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM Site plan/survey and landscape plan rear patio layout does not match plans Site plan/survey must show platted easements. This lot has a 10ft easement on the left side | |||
| URB | COMPLETE | 02/25/2022 | 03/02/2022 |
| Note: Released By: JOHN BEAUDET - (386)986-2456 - | |||
| PLFM | HOLD | 02/25/2022 | 02/25/2022 |
| Note: Held By: JORDAN MYERS, C.F.M - (386)986-2320 - JMYERS@PALMCOASTGOV.COM Site Plan/Survey need flood zone information and lines on the plans. Should the structure fall inside the SFHA elevation Certificate will be required at construction, foundation, and final. | |||
| PLENV | COMPLETE | 02/25/2022 | 02/28/2022 |
| Note: Released By: JORDAN MYERS, C.F.M - (386)986-2320 - JMYERS@PALMCOASTGOV.COM Staff conducted a site visit on 2/28/22 and found no Gopher Tortoise or their burrows. Staff suggests placing silt fence as soon as possible to prevent tortoise from moving into the lot. |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| CONTRACTOR CHANGE | ¤20.00 | 11/21/2023 |
| CONTRACTOR CHANGE | ¤40.00 | 11/21/2023 |
| SW ENG REINSPECTION 30 | ¤30.00 | 11/21/2023 |
| PLAN REVIEW - REVISION | ¤32.50 | 11/21/2023 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 11/21/2023 |
| CONNECTION FEES | ¤25.00 | 03/29/2022 |
| WATER-METER | ¤467.09 | 03/29/2022 |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | 03/29/2022 |
| INSPECTION - RESIDENTIAL | ¤1,787.50 | 03/29/2022 |
| PLAN REVIEW - RESIDENTIAL | ¤507.00 | 03/29/2022 |
| PLAN REVIEW - REVISION | ¤32.50 | 03/29/2022 |
| SW ENG - REVIEW 20 | ¤20.00 | 03/29/2022 |
| SW ENG RES REVIEW 200 | ¤200.00 | 03/29/2022 |
| 3% TRANS IMPACT FEE CREDIT | (¤96.72) | 03/29/2022 |
| SEWER INSPECTION | ¤25.00 | 03/29/2022 |
| SEWER CAPITAL FACILITY | ¤4,939.76 | 03/29/2022 |
| WATER CAPITAL FACILITY FEE | ¤3,626.50 | 03/29/2022 |
| SITE PLAN 30 | ¤30.00 | 03/29/2022 |
| 3% FIRE IMPACT FEE CREDIT | (¤11.66) | 03/29/2022 |
| IMPACT FEE FIRE | ¤388.65 | 03/29/2022 |
| IMPACT FEE PARKS | ¤1,455.13 | 03/29/2022 |
| IMPACT FEE SCHOOL | ¤3,600.00 | 03/29/2022 |
| IMPACT FEE TRANSPORTATION | ¤3,224.00 | 03/29/2022 |
| 3% PARKS IMPACT FEE CREDIT | (¤43.65) | 03/29/2022 |
| SURCHARGE FS 533.721 | ¤24.15 | 03/29/2022 |
| SURCHARGE - FS 468.631 | ¤36.22 | 03/29/2022 |
| SW ENG - FOUNDATION SURVEY | ¤20.00 | 03/29/2022 |
| SW ENG INSPECTION 80 | ¤80.00 | 03/29/2022 |
| SW ENG PRE APRON | ¤30.00 | 03/29/2022 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤20,558.97 |