Permit #2022030501

Permit Details

Status: FINAL

Parcel Id: 07-11-31-5112-00000-0050
Block: 00000
Subdivision: 1164 - PINE LAKES INDUSTRIAL PARK
Job Phone: 386-238-1570
Location Address: 11 COMMERCE BLVD
Type: CIA - COMMERCIAL INTERIOR EXTERIOR ALTERATION
Issue Date: 08/26/2022
NOC: RECORDED
Applicant name: GARY LYNN ROBERTS
Owner: 11 COMMERCE EQUITIES LLC & 11 COMMERCE ROBLES LLC

Address

ATTN: SCOTT GLAUBERG 24 CHURCH STREET

MONTCLAIR, NJ 07042

Lot: 0050
Contracted Stated Job Value: ¤215,000.00
Job Description: UNIT 5 - INTERIOR & EXTERIOR ADA IMPROVEMENTS
Type: CN

Contractor

COMMERCIAL CONSTRUCTION INC.
Status Location Address State License Number Phone Fax
ACTIVE

7 SUNSHINE BLVD

ORMOND BEACH, FL 32174

CGC059441 (Exp: 08/31/2026) 386-238-1570 386-238-1571

Sub Contractors

MICHAEL WAYNE LYNCH
Status Location Address Mailing Address State License Number Phone
INACTIVE

512 FENTRESS BLVD

DAYTONA BEACH, FL 32114

STE I

DAYTONA BEACH, FL 32114

ER13015626 (Exp: 08/31/2023) 386-313-1719

Inspection History

Type Request Date Result Inspector
U - UTILITY COMMERCIAL FINAL 10/09/2023 FINAL APPROVED LFITZGERALD
FIRE FINAL 10/06/2023 FINAL APPROVED CPISCITELLI
Note: 9/15/2023 - PREVIOUS INSPECTION NOTES missing emergency lighting 2 areas wrong type fire extinguisher 2 locations missing unit address on doors fire alarm panel not shutting dampers and no notfication device in unit 5 office and warehouse no fire extinguisher signage and FACP signage not on door
BUILDING FINAL 10/06/2023 FINAL APPROVED FWILLIS
FIRE FINAL 09/15/2023 Disapproved - NO FEE CPISCITELLI
Note: missing emergency lighting 2 areas wrong type fire extinguisher 2 locations missing unit address on doors fire alarm panel not shutting dampers and no notfication device in unit 5 office and warehouse no fire extinguisher signage and FACP signage not on door
HVAC FINAL 09/15/2023 FINAL APPROVED CPISCITELLI
Note: 4/20/2023 - PREVIOUS INSPECTION NOTES 3/3/2023 - PREVIOUS INSPECTION NOTES
ELECTRIC FINAL 09/15/2023 APPROVED RMARTIN
ABOVE CEILING 09/15/2023 APPROVED RMARTIN
Note: 3/3/2023 - PREVIOUS INSPECTION NOTES need to safe off all open boxes, panels, conductors in ceiling
FIREWALL NAILING 04/20/2023 APPROVED FWILLIS
Note: 3/3/2023 - PREVIOUS INSPECTION NOTES 3/3/23 Firewall drywall was inspected on 11/21/22. No new areas have been done. This inspection will be partial due to second phase not started. Note to contractor ensure fire door hardware is installed. Over head door is missing a door detail OO1-B on page A 3-01. HVAC fire damper through fire wall atop of the over head door has not been sealed. Seal all gaps at the fill in fire wall areas. 11/21/2022 - PREVIOUS INSPECTION NOTES Highlighted on Plans.
HVAC FINAL 04/20/2023 CANCELLED BY APPLICANT CPISCITELLI
Note: 3/3/2023 - PREVIOUS INSPECTION NOTES
FIRE FINAL 04/20/2023 CANCELLED BY APPLICANT CPISCITELLI
Note: 3/3/2023 - PREVIOUS INSPECTION NOTES Cancelled not ready
UC-FINAL SITE INSPECTION 04/20/2023 CANCELLED BY INSPECTOR LFITZGERALD
Note: spoke with Jeff who explained that work related to this inspection for unit 5 was omitted and will be done in another permit for unit8(where Palm Coast data was)-only a new sidewalk was installed for 2nd egress path for side entrances
HVAC ROUGH 03/28/2023 PARTIALLY APPROVED CPISCITELLI
Note: Inspected damper in duct through fire separation and duct in common area to wrap
HVAC ROUGH 03/06/2023 CANCELLED BY APPLICANT WEB
HVAC ROUGH 03/03/2023 CANCELLED BY APPLICANT CPISCITELLI
HVAC FINAL 03/03/2023 CANCELLED BY APPLICANT CPISCITELLI
ELECTRIC FINAL 03/03/2023 CANCELLED BY INSPECTOR RMARTIN
ABOVE CEILING 03/03/2023 Disapproved - NO FEE RMARTIN
Note: need to safe off all open boxes, panels, conductors in ceiling
FIREWALL NAILING 03/03/2023 PARTIALLY APPROVED JWALKER
Note: 3/3/23 Firewall drywall was inspected on 11/21/22. No new areas have been done. This inspection will be partial due to second phase not started. Note to contractor ensure fire door hardware is installed. Over head door is missing a door detail OO1-B on page A 3-01. HVAC fire damper through fire wall atop of the over head door has not been sealed. Seal all gaps at the fill in fire wall areas. 11/21/2022 - PREVIOUS INSPECTION NOTES Highlighted on Plans.
FIRE FINAL 03/03/2023 CANCELLED BY APPLICANT LMILLER
Note: Cancelled not ready
FIREWALL NAILING 11/21/2022 PARTIALLY APPROVED FWILLIS
Note: Highlighted on Plans.
FIREWALL NAILING 11/07/2022 APPROVED FWILLIS
Note: SCREW INSPECTION ALL AREAS.
FRAMING 11/01/2022 APPROVED FWILLIS
ELECTRIC 2ND ROUGH 11/01/2022 APPROVED RMARTIN

Review History

Department Status Date In Date Out
FI1 COMPLETE 08/15/2022 08/24/2022
Note: Released By: LEE MILLER - (386)986-3783 - WMILLER@PALMCOASTGOV.COM
BLD COMPLETE 08/15/2022 08/22/2022
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
ELEC COMPLETE 07/06/2022 07/11/2022
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
MECH COMPLETE 07/06/2022 07/07/2022
Note: Released By: CHRIS PISCITELLI - (386)986-3782 - CPISCITELLI@PALMCOASTGOV.COM
BLD HOLD 07/06/2022 07/20/2022
Note: Held By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM All comments below per the 2020 Florida Building Code REVIEW COMMENTS: Repeat Comment 1. OK 2. OK 3. OK 4. OK 5. OK 6. OK 7. OK 8. OK 9. OK 10. OK 11. OK 12. OK 13. Provide details for the proposed ADA concrete ramp and rails. Requirements per 405 2020 Florida Accessibility Code. 14. OK 15. OK 16. OK 17. OK 18. Revise Life Safety Summary to match the occupant load and correct units shown on the submitted drawings. Revise the Common Path of Egress from the most remote point. One egress path exceeds the limits of Table 1017.2.
FI1 HOLD 07/06/2022 07/18/2022
Note: Held By: LEE MILLER - (386)986-3783 - WMILLER@PALMCOASTGOV.COM Please provide a written response to each comment below in a response letter and provide clouded response changes on plan sheets. Additional comment are likely at the next review 1. Provide code analysis using Chapter 7, Chapter 10 and Chapter 11 of the FBC Existing Building 2020 7th edition, FFPC 2020 7th edition, NFPA 10 (2018), NFPA 72 (2016), and NFPA 13 (2016) (this was still not answered in its entirety). 2. The Classification of Hazard of Contents needs to be listed under on the following (a) Low Hazard (b) Ordinary Hazard (c) High Hazard Per FFPC 101, Life Safety Code 6.2.2 (The answer to Hazard of Contents from the prior review on sheet A0.01 does not use the nomenclature per the FFPC, Please use Nomenclature provided in the per FFPC 101, 6.2.2.1 through 6.2.2.4 for review )
BADMIN INFORMATION 07/05/2022 07/05/2022
Note: Marked INFORMATION By: MICHELLE RAMOS - - MRAMOS@PALMCOASTGOV.COM 1. Please remove 21050 from file name 2. Please rename files for plans C1, C2, C3 to C1.pdf, C2.pdf and C3.pdf 3. Please rename energy calcs to energy calcs. 4. Please rename to supporting doc.pdf
BLD HOLD 05/20/2022 05/27/2022
Note: Held By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM All comments below per the 2020 Florida Building Code REVIEW COMMENTS: Repeat Comment 1. OK 2. OK 3. OK 4. OK 5. OK 6. OK 7. OK 8. OK 9. OK 10. OK 11. OK 12. Office Space for Unit #1 exit’s thru a common area. As mentioned above, the common area appears to be a load dock. The exit path puts restrictions on this area do to probability of obstruction to possible free egress path of travel. 1016.2 FBC 2020 13. Provide details for the proposed ADA concrete ramp and rails. Requirements per 405 2020 Florida Accessibility Code. 14. Provide calculations for ADA accessible spaces per 206, 2020 Florida Accessibility Code. 15. OK 16. Sheet A2.01 was revised and submitted as Overall Building Plan. Previous sheet A2.01 is Demo Plan. Provide which is correct (New Comment) 17. Existing bathroom door is being removed. Provide fire rated doors throughout the corridor. FBC 706.5. (New Comment) 18. Revise Life Safety Summary to match the occupant load and correct units shown on the submitted drawings.
PLUM COMPLETE 05/20/2022 05/26/2022
Note: Released By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM
MECH HOLD 05/20/2022 05/23/2022
Note: Held By: CHRIS PISCITELLI - (386)986-3782 - CPISCITELLI@PALMCOASTGOV.COM 2. Provide heatload calculation for all spaces per C403.2.1 FBC Energy Conservation 2020 7th edition. (This is a level 2 alteration) 3. Provide Duct layout showing supply, return, for offices. (Existing offices not built with permit. Need to be brought up to code) ( Layout must show duct sizes and CFM Requirements) 5. Provide location of all thermostats (Not on Plans) (Third Request)
FI1 HOLD 05/20/2022 06/06/2022
Note: Held By: LEE MILLER - (386)986-3783 - WMILLER@PALMCOASTGOV.COM Please provide a written response to each comment below in a response letter and provide clouded response changes on plan sheets. 1. Provide code analysis using Chapter 7, Chapter 10 and Chapter 11 of the FBC Existing Building 2020 7th edition, FFPC 2020 7th edition, NFPA 10 (2018), NFPA 72 (2016), and NFPA 13 (2016) (this was not answered in its entirety). 2. Provide penetration details for fire resistive rated walls for copper line sets and drain lines per FBC Building 717.1.2 and 714.4.2 (it is not common practice to answer a comment question by sending the reviewer to a separate reviewers comment response to see the results, also the answer was not answered. (Please answer the response comment in the response letter for the reviewer) 3. In order to take the reduction of Fire Separation Barrier between Storage and Business down to 1-Hour PER FFPC 1 TBL 6.1.14.4.1. (B), the Building must be equipped with an approved Fire Sprinkler System in accordance with NFPA 13 Per 7th Edition FFPC 1, 6.1.14.4.3 and 7th Edition FFPC 101, 6.1.14.4.3 and must be supervised in accordance with 7th Edition FFPC 1, 13.3.1.8. (please provide details in code analysis indicating if the building is currently sprinklered or will be sprinklered to comply) (This was not answered in the code analysis). 4. Please have the registered design professional (RDP) or owner classify the hazard of contents for review and approval on the basis of the character of the contents and the processes or operations conducted in the building or structure. FFPC 101, Life Safety Code 6.2.1.2 (this was not answered and must be answered with the submittal in the analysis) 5. Please provide travel distance for Extinguishers not exceeding the limits of travel per FFPC 1, TABLES 13.6.3.2.1.1 & 13.6.3.3.1.1 According to Classification and type of Hazard. (Travel distance to extinguishers was not included and Travel distance according to classification of hazard was also not included).
ELEC COMPLETE 05/20/2022 05/23/2022
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
ELEC COMPLETE 05/16/2022 05/17/2022
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM Electric drawings will be submitted at the time of inspections
MECH HOLD 05/16/2022 05/17/2022
Note: Held By: CHRIS PISCITELLI - (386)986-3782 - CPISCITELLI@PALMCOASTGOV.COM 1. Provide ventilation calculation for all spaces per M403.3.1.1 FBC Mechanical 2020 7th edition 2. Provide heatload calculation for all spaces per C403.2.1 FBC Energy Conservation 2020 7th edition 3. Provide Duct layout showing supply, return, fresh air, and exhaust. Include new and proposed changes. (Existing offices not built with permit. Need to be brought up to code) 4. Provide locations of all AHU's 5. Provide location of all thermostats (Second Request)
FI1 HOLD 05/16/2022 05/20/2022
Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM Please provide a written response to each comment below in a response letter and provide clouded response changes on plan sheets. 1. Provide code analysis using Chapter 7, Chapter 10 and Chapter 11 of the FBC Existing Building 2020 7th edition, FFPC 2020 7th edition, NFPA 10 (2018), NFPA 72 (2016), and NFPA 13 (2016) 2. Provide response detailing use of tenant spaces 3. Provide penetration details for fire resistive rated walls for copper linesets and drain lines per FBC Building 717.1.2 and 714.4.2 4. In order to take the reduction of Fire Separation Barrier between Storage and Business down to 1-Hour PER FFPC 1 TBL 6.1.14.4.1. (B), the Building must be equipped with an approved Fire Sprinkler System in accordance with NFPA 13 Per 7th Edition FFPC 1, 6.1.14.4.3 and 7th Edition FFPC 101, 6.1.14.4.3 and must be supervised in accordance with 7th Edition FFPC 1, 13.3.1.8. (please provide details in code analysis indicating if the building is currently sprinklered or will be sprinklered to comply) 5. Please have the registered design professional (RDP) or owner classify the hazard of contents for review and approval on the basis of the character of the contents and the processes or operations conducted in the building or structure. FFPC 101, Life Safety Code 6.2.1.2 6. Please provide travel distance for Extinguishers not exceeding the limits of travel per FFPC 1, TABLES 13.6.3.2.1.1 & 13.6.3.3.1.1 According to Classification and type of Hazard.
BLD HOLD 05/16/2022 05/17/2022
Note: Held By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM All comments below per the 2020 Florida Building Code REVIEW COMMENTS: Repeat Comment 1. OK 2. OK 3. Existing occupancy classification is noted as F-2 and Business. Provide what is being manufactured and if there is any storage occupancy. 4. Provide the existing type of building construction. Plans call-out existing without noting the existing building construction type. 5. Travel distance is noted 400 ft. Revise the travel distance to the most restrictive occupancy per Table 1017.2. 6. OK 7. The existing use is called-out as F-2 and B. The Life Safety Summary calls-out B and S-1. Revise to reflect the correct occupancy for the proposed tenant space. 8. OK 9. Revise Demo Notes to correlate to reflect the correct work to be performed. 10. Rollup door 001B is called-out. Opening Schedule dos not reflect the door. Door is part of a rated assemble. Door Types on sheet A3.0 do not match the call-outs on the Floor Plan and the Opening Schedule. Revise to reflect the correct doors are called-out. 11. Tenant Common Space has overhead doors. Provide clarity if this a shared Loading Dock or Lobby for the multiple tenant space. 12. Office Space for Unit #1 exit’s thru a common area. As mentioned above, the common area appears to be a load dock. The exit path puts restrictions on this area do to probability of obstruction to possible free egress path of travel. 1016.2 FBC 2020 13. Provide details for the proposed ADA concrete ramp and rails. Requirements per 405 2020 Florida Accessibility Code. 14. Provide calculations for ADA accessible spaces per 206, 2020 Florida Accessibility Code. 15. Provide interior wall and ceiling finish materials per 803.1.1 16. Sheet A2.01 was revised and submitted as Overall Building Plan. Previous sheet A2.01 is Demo Plan. Provide which is correct (New Comment)
PLUM HOLD 05/16/2022 05/17/2022
Note: Held By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM All comments below per the 2020 Florida Building Code – Plumbing REVIEW COMMENTS: Repeat Comments 1. OK 2. Both occupancies called-out require a service sink. Table 403.1
BLD HOLD 03/09/2022 03/23/2022
Note: Held By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM All comments below per the 2020 Florida Building Code REVIEW COMMENTS: 1. Provide an over plan tenant layout plan. The plan is to show all spaces of the building and there use. 2. Provide a Code Analysis per the Existing Building Code. Provide the compliance method used. 3. Existing occupancy classification is noted as F-2 and Business. Provide what is being manufactured and if there is any storage occupancy. 4. Provide the existing type of building construction. Plans call-out existing without noting the existing building construction type. 5. Travel distance is noted 400 ft. Revise the travel distance to the most restrictive occupancy per Table 1017.2. 6. Dead End Corridor distance far exceeds the distance requirements per 1020.4. 7. The existing use is called-out as F-2 and B. The Life Safety Summary calls-out B and S-1. Revise to reflect the correct occupancy for the proposed tenant space. 8. Note under the Life Safety Summary reference the 2022 Building Code. As of January 1, 2021, Florida State adopted the 2020 Florida Building Codes. A revision to the note is required to reflect the correct Code cycle. 9. Revise Demo Notes to correlate to reflect the correct work to be performed. 10. Rollup door 001B is called-out. Opening Schedule dos not reflect the door. Door is part of a rated assemble. Door Types on sheet A3.0 do not match the call-outs on the Floor Plan and the Opening Schedule. Revise to reflect the correct doors are called-out. 11. Tenant Common Space has overhead doors. Provide clarity if this a shared Loading Dock or Lobby for the multiple tenant space. 12. Office Space for Unit #1 exit’s thru a common area. As mentioned above, the common area appears to be a load dock. The exit path puts restrictions on this area do to probability of obstruction to possible free egress path of travel. 1016.2 FBC 2020 13. Provide details for the proposed ADA concrete ramp and rails. Requirements per 405 2020 Florida Accessibility Code. 14. Provide calculations for ADA accessible spaces per 206, 2020 Florida Accessibility Code. 15. Provide interior wall and ceiling finish materials per 803.1.1
DSD COMPLETE 03/09/2022 03/14/2022
Note: Released By: JACQUELINE GONZALEZ - (386)986-3751 - JGONZALEZ@PALMCOASTGOV.COM
ELEC HOLD 03/09/2022 03/14/2022
Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. Need to submit Electrical plans proposed and existing. 2. These were not tenant spaces before so you need to submit some kind of written response of what is going in these spots. 3. Tenants shall have ready access of the circuit breakers. NEC 2017 240.24 (B) 4. Submit a code analyst 5. Need to show the size of the services for each tenant. 6. Need to note if the generator is existing. If not submit manufacture specs on generator and a riser diagram.
FI1 HOLD 03/09/2022 03/23/2022
Note: Held By: LEE MILLER - (386)986-3783 - WMILLER@PALMCOASTGOV.COM Please provide a written response to each comment below in a response letter and provide clouded response changes on plan sheets. 1. Provide code analysis using Chapter 7, Chapter 10 and Chapter 11 of the FBC Existing Building 2020 7th edition, FFPC 2020 7th edition, NFPA 10 (2018), NFPA 72 (2016), and NFPA 13 (2016) 2. Provide response detailing use of tenant spaces 3. Provide penetration details for fire resistive rated walls for copper linesets and drain lines per FBC Building 717.1.2 and 714.4.2 4. In order to take the reduction of Fire Separation Barrier between Storage and Business down to 1-Hour PER FFPC 1 TBL 6.1.14.4.1. (B), the Building must be equipped with an approved Fire Sprinkler System in accordance with NFPA 13 Per 7th Edition FFPC 1, 6.1.14.4.3 and 7th Edition FFPC 101, 6.1.14.4.3 and must be supervised in accordance with 7th Edition FFPC 1, 13.3.1.8. (please provide details in code analysis indicating if the building is currently sprinklered or will be sprinklered to comply) 5. Please have the registered design professional (RDP) or owner classify the hazard of contents for review and approval on the basis of the character of the contents and the processes or operations conducted in the building or structure. FFPC 101, Life Safety Code 6.2.1.2 6. Please provide travel distance for Extinguishers not exceeding the limits of travel per FFPC 1, TABLES 13.6.3.2.1.1 & 13.6.3.3.1.1 According to Classification and type of Hazard.
MECH HOLD 03/09/2022 03/18/2022
Note: Held By: CHRIS PISCITELLI - (386)986-3782 - CPISCITELLI@PALMCOASTGOV.COM 1. Provide code analysis using Chapter 7, Chapter 10 and Chapter 11 of the FBC Existing Building 2020 7th edition 2. Provide responce detailing use of tenant spaces 3. Provide ventilation calculation for all spaces per M403.3.1.1 FBC Mechanical 2020 7th edition 4. Provide heatload calculation for all spaces per C403.2.1 FBC Energy Conservation 2020 7th edition 5. Provide Duct layout showing supply, return, fresh air, and exhaust. Include new and proposed changes 6. Provide penetration details for fire resistive rated walls for copper linesets and drain lines per FBC Building 717.1.2 and 714.4.2 7. Provide locations of all AHU's 8. Provide location of all thermostats
PLUM HOLD 03/09/2022 03/23/2022
Note: Held By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM All comments below per the 2020 Florida Building Code – Plumbing REVIEW COMMENTS: 1. Provide fixture calculations for each space and based on each use. Section 403. 2. Both occupancies called-out require a service sink. Table 403.1
UD1 COMPLETE 03/09/2022 03/09/2022
Note: Released By: CHRIS JOHNSON - (386)986-2384 - CJOHNSON@PALMCOASTGOV.COM

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
ADJUSTMENT 50% (¤913.63) 08/26/2022
ADMINISTRATIVE - COMMERCIAL ¤75.00 08/26/2022
INSPECTION COMMERCIAL ¤1,505.00 08/26/2022
PLAN REVIEW - COMMERCIAL ¤247.25 08/26/2022
SURCHARGE FS 533.721 ¤9.68 08/26/2022
SURCHARGE - FS 468.631 ¤14.52 08/26/2022
SITE PLAN 30 ¤30.00 08/26/2022
Fees Total Due: ¤0.00 Total Paid: ¤967.82