I want to search for...
Permit #2022030501
Permit Details
Status: FINAL
| Parcel Id: 07-11-31-5112-00000-0050 |
| Block: 00000 |
| Subdivision: 1164 - PINE LAKES INDUSTRIAL PARK |
| Job Phone: 386-238-1570 |
| Location Address: 11 COMMERCE BLVD |
| Type: CIA - COMMERCIAL INTERIOR EXTERIOR ALTERATION |
| Issue Date: 08/26/2022 |
| NOC: RECORDED |
| Applicant name: GARY LYNN ROBERTS |
| Owner: 11 COMMERCE EQUITIES LLC & 11 COMMERCE ROBLES LLC |
|
Address ATTN: SCOTT GLAUBERG 24 CHURCH STREET MONTCLAIR, NJ 07042 |
| Lot: 0050 |
| Contracted Stated Job Value: ¤215,000.00 |
| Job Description: UNIT 5 - INTERIOR & EXTERIOR ADA IMPROVEMENTS |
| Type: CN |
Contractor
COMMERCIAL CONSTRUCTION INC.
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
7 SUNSHINE BLVD ORMOND BEACH, FL 32174 |
CGC059441 (Exp: 08/31/2026) | 386-238-1570 | 386-238-1571 |
Sub Contractors
MICHAEL WAYNE LYNCH
| Status | Location Address | Mailing Address | State License Number | Phone |
| INACTIVE |
512 FENTRESS BLVD DAYTONA BEACH, FL 32114 |
STE I DAYTONA BEACH, FL 32114 |
ER13015626 (Exp: 08/31/2023) | 386-313-1719 |
Inspection History
| Type | Request Date | Result | Inspector |
| U - UTILITY COMMERCIAL FINAL | 10/09/2023 | FINAL APPROVED | LFITZGERALD |
| FIRE FINAL | 10/06/2023 | FINAL APPROVED | CPISCITELLI |
| Note: 9/15/2023 - PREVIOUS INSPECTION NOTES missing emergency lighting 2 areas wrong type fire extinguisher 2 locations missing unit address on doors fire alarm panel not shutting dampers and no notfication device in unit 5 office and warehouse no fire extinguisher signage and FACP signage not on door | |||
| BUILDING FINAL | 10/06/2023 | FINAL APPROVED | FWILLIS |
| FIRE FINAL | 09/15/2023 | Disapproved - NO FEE | CPISCITELLI |
| Note: missing emergency lighting 2 areas wrong type fire extinguisher 2 locations missing unit address on doors fire alarm panel not shutting dampers and no notfication device in unit 5 office and warehouse no fire extinguisher signage and FACP signage not on door | |||
| HVAC FINAL | 09/15/2023 | FINAL APPROVED | CPISCITELLI |
| Note: 4/20/2023 - PREVIOUS INSPECTION NOTES 3/3/2023 - PREVIOUS INSPECTION NOTES | |||
| ELECTRIC FINAL | 09/15/2023 | APPROVED | RMARTIN |
| ABOVE CEILING | 09/15/2023 | APPROVED | RMARTIN |
| Note: 3/3/2023 - PREVIOUS INSPECTION NOTES need to safe off all open boxes, panels, conductors in ceiling | |||
| FIREWALL NAILING | 04/20/2023 | APPROVED | FWILLIS |
| Note: 3/3/2023 - PREVIOUS INSPECTION NOTES 3/3/23 Firewall drywall was inspected on 11/21/22. No new areas have been done. This inspection will be partial due to second phase not started. Note to contractor ensure fire door hardware is installed. Over head door is missing a door detail OO1-B on page A 3-01. HVAC fire damper through fire wall atop of the over head door has not been sealed. Seal all gaps at the fill in fire wall areas. 11/21/2022 - PREVIOUS INSPECTION NOTES Highlighted on Plans. | |||
| HVAC FINAL | 04/20/2023 | CANCELLED BY APPLICANT | CPISCITELLI |
| Note: 3/3/2023 - PREVIOUS INSPECTION NOTES | |||
| FIRE FINAL | 04/20/2023 | CANCELLED BY APPLICANT | CPISCITELLI |
| Note: 3/3/2023 - PREVIOUS INSPECTION NOTES Cancelled not ready | |||
| UC-FINAL SITE INSPECTION | 04/20/2023 | CANCELLED BY INSPECTOR | LFITZGERALD |
| Note: spoke with Jeff who explained that work related to this inspection for unit 5 was omitted and will be done in another permit for unit8(where Palm Coast data was)-only a new sidewalk was installed for 2nd egress path for side entrances | |||
| HVAC ROUGH | 03/28/2023 | PARTIALLY APPROVED | CPISCITELLI |
| Note: Inspected damper in duct through fire separation and duct in common area to wrap | |||
| HVAC ROUGH | 03/06/2023 | CANCELLED BY APPLICANT | WEB |
| HVAC ROUGH | 03/03/2023 | CANCELLED BY APPLICANT | CPISCITELLI |
| HVAC FINAL | 03/03/2023 | CANCELLED BY APPLICANT | CPISCITELLI |
| ELECTRIC FINAL | 03/03/2023 | CANCELLED BY INSPECTOR | RMARTIN |
| ABOVE CEILING | 03/03/2023 | Disapproved - NO FEE | RMARTIN |
| Note: need to safe off all open boxes, panels, conductors in ceiling | |||
| FIREWALL NAILING | 03/03/2023 | PARTIALLY APPROVED | JWALKER |
| Note: 3/3/23 Firewall drywall was inspected on 11/21/22. No new areas have been done. This inspection will be partial due to second phase not started. Note to contractor ensure fire door hardware is installed. Over head door is missing a door detail OO1-B on page A 3-01. HVAC fire damper through fire wall atop of the over head door has not been sealed. Seal all gaps at the fill in fire wall areas. 11/21/2022 - PREVIOUS INSPECTION NOTES Highlighted on Plans. | |||
| FIRE FINAL | 03/03/2023 | CANCELLED BY APPLICANT | LMILLER |
| Note: Cancelled not ready | |||
| FIREWALL NAILING | 11/21/2022 | PARTIALLY APPROVED | FWILLIS |
| Note: Highlighted on Plans. | |||
| FIREWALL NAILING | 11/07/2022 | APPROVED | FWILLIS |
| Note: SCREW INSPECTION ALL AREAS. | |||
| FRAMING | 11/01/2022 | APPROVED | FWILLIS |
| ELECTRIC 2ND ROUGH | 11/01/2022 | APPROVED | RMARTIN |
Review History
| Department | Status | Date In | Date Out |
| FI1 | COMPLETE | 08/15/2022 | 08/24/2022 |
| Note: Released By: LEE MILLER - (386)986-3783 - WMILLER@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 08/15/2022 | 08/22/2022 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| ELEC | COMPLETE | 07/06/2022 | 07/11/2022 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| MECH | COMPLETE | 07/06/2022 | 07/07/2022 |
| Note: Released By: CHRIS PISCITELLI - (386)986-3782 - CPISCITELLI@PALMCOASTGOV.COM | |||
| BLD | HOLD | 07/06/2022 | 07/20/2022 |
| Note: Held By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM All comments below per the 2020 Florida Building Code REVIEW COMMENTS: Repeat Comment 1. OK 2. OK 3. OK 4. OK 5. OK 6. OK 7. OK 8. OK 9. OK 10. OK 11. OK 12. OK 13. Provide details for the proposed ADA concrete ramp and rails. Requirements per 405 2020 Florida Accessibility Code. 14. OK 15. OK 16. OK 17. OK 18. Revise Life Safety Summary to match the occupant load and correct units shown on the submitted drawings. Revise the Common Path of Egress from the most remote point. One egress path exceeds the limits of Table 1017.2. | |||
| FI1 | HOLD | 07/06/2022 | 07/18/2022 |
| Note: Held By: LEE MILLER - (386)986-3783 - WMILLER@PALMCOASTGOV.COM Please provide a written response to each comment below in a response letter and provide clouded response changes on plan sheets. Additional comment are likely at the next review 1. Provide code analysis using Chapter 7, Chapter 10 and Chapter 11 of the FBC Existing Building 2020 7th edition, FFPC 2020 7th edition, NFPA 10 (2018), NFPA 72 (2016), and NFPA 13 (2016) (this was still not answered in its entirety). 2. The Classification of Hazard of Contents needs to be listed under on the following (a) Low Hazard (b) Ordinary Hazard (c) High Hazard Per FFPC 101, Life Safety Code 6.2.2 (The answer to Hazard of Contents from the prior review on sheet A0.01 does not use the nomenclature per the FFPC, Please use Nomenclature provided in the per FFPC 101, 6.2.2.1 through 6.2.2.4 for review ) | |||
| BADMIN | INFORMATION | 07/05/2022 | 07/05/2022 |
| Note: Marked INFORMATION By: MICHELLE RAMOS - - MRAMOS@PALMCOASTGOV.COM 1. Please remove 21050 from file name 2. Please rename files for plans C1, C2, C3 to C1.pdf, C2.pdf and C3.pdf 3. Please rename energy calcs to energy calcs. 4. Please rename to supporting doc.pdf | |||
| BLD | HOLD | 05/20/2022 | 05/27/2022 |
| Note: Held By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM All comments below per the 2020 Florida Building Code REVIEW COMMENTS: Repeat Comment 1. OK 2. OK 3. OK 4. OK 5. OK 6. OK 7. OK 8. OK 9. OK 10. OK 11. OK 12. Office Space for Unit #1 exit’s thru a common area. As mentioned above, the common area appears to be a load dock. The exit path puts restrictions on this area do to probability of obstruction to possible free egress path of travel. 1016.2 FBC 2020 13. Provide details for the proposed ADA concrete ramp and rails. Requirements per 405 2020 Florida Accessibility Code. 14. Provide calculations for ADA accessible spaces per 206, 2020 Florida Accessibility Code. 15. OK 16. Sheet A2.01 was revised and submitted as Overall Building Plan. Previous sheet A2.01 is Demo Plan. Provide which is correct (New Comment) 17. Existing bathroom door is being removed. Provide fire rated doors throughout the corridor. FBC 706.5. (New Comment) 18. Revise Life Safety Summary to match the occupant load and correct units shown on the submitted drawings. | |||
| PLUM | COMPLETE | 05/20/2022 | 05/26/2022 |
| Note: Released By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM | |||
| MECH | HOLD | 05/20/2022 | 05/23/2022 |
| Note: Held By: CHRIS PISCITELLI - (386)986-3782 - CPISCITELLI@PALMCOASTGOV.COM 2. Provide heatload calculation for all spaces per C403.2.1 FBC Energy Conservation 2020 7th edition. (This is a level 2 alteration) 3. Provide Duct layout showing supply, return, for offices. (Existing offices not built with permit. Need to be brought up to code) ( Layout must show duct sizes and CFM Requirements) 5. Provide location of all thermostats (Not on Plans) (Third Request) | |||
| FI1 | HOLD | 05/20/2022 | 06/06/2022 |
| Note: Held By: LEE MILLER - (386)986-3783 - WMILLER@PALMCOASTGOV.COM Please provide a written response to each comment below in a response letter and provide clouded response changes on plan sheets. 1. Provide code analysis using Chapter 7, Chapter 10 and Chapter 11 of the FBC Existing Building 2020 7th edition, FFPC 2020 7th edition, NFPA 10 (2018), NFPA 72 (2016), and NFPA 13 (2016) (this was not answered in its entirety). 2. Provide penetration details for fire resistive rated walls for copper line sets and drain lines per FBC Building 717.1.2 and 714.4.2 (it is not common practice to answer a comment question by sending the reviewer to a separate reviewers comment response to see the results, also the answer was not answered. (Please answer the response comment in the response letter for the reviewer) 3. In order to take the reduction of Fire Separation Barrier between Storage and Business down to 1-Hour PER FFPC 1 TBL 6.1.14.4.1. (B), the Building must be equipped with an approved Fire Sprinkler System in accordance with NFPA 13 Per 7th Edition FFPC 1, 6.1.14.4.3 and 7th Edition FFPC 101, 6.1.14.4.3 and must be supervised in accordance with 7th Edition FFPC 1, 13.3.1.8. (please provide details in code analysis indicating if the building is currently sprinklered or will be sprinklered to comply) (This was not answered in the code analysis). 4. Please have the registered design professional (RDP) or owner classify the hazard of contents for review and approval on the basis of the character of the contents and the processes or operations conducted in the building or structure. FFPC 101, Life Safety Code 6.2.1.2 (this was not answered and must be answered with the submittal in the analysis) 5. Please provide travel distance for Extinguishers not exceeding the limits of travel per FFPC 1, TABLES 13.6.3.2.1.1 & 13.6.3.3.1.1 According to Classification and type of Hazard. (Travel distance to extinguishers was not included and Travel distance according to classification of hazard was also not included). | |||
| ELEC | COMPLETE | 05/20/2022 | 05/23/2022 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| ELEC | COMPLETE | 05/16/2022 | 05/17/2022 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM Electric drawings will be submitted at the time of inspections | |||
| MECH | HOLD | 05/16/2022 | 05/17/2022 |
| Note: Held By: CHRIS PISCITELLI - (386)986-3782 - CPISCITELLI@PALMCOASTGOV.COM 1. Provide ventilation calculation for all spaces per M403.3.1.1 FBC Mechanical 2020 7th edition 2. Provide heatload calculation for all spaces per C403.2.1 FBC Energy Conservation 2020 7th edition 3. Provide Duct layout showing supply, return, fresh air, and exhaust. Include new and proposed changes. (Existing offices not built with permit. Need to be brought up to code) 4. Provide locations of all AHU's 5. Provide location of all thermostats (Second Request) | |||
| FI1 | HOLD | 05/16/2022 | 05/20/2022 |
| Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM Please provide a written response to each comment below in a response letter and provide clouded response changes on plan sheets. 1. Provide code analysis using Chapter 7, Chapter 10 and Chapter 11 of the FBC Existing Building 2020 7th edition, FFPC 2020 7th edition, NFPA 10 (2018), NFPA 72 (2016), and NFPA 13 (2016) 2. Provide response detailing use of tenant spaces 3. Provide penetration details for fire resistive rated walls for copper linesets and drain lines per FBC Building 717.1.2 and 714.4.2 4. In order to take the reduction of Fire Separation Barrier between Storage and Business down to 1-Hour PER FFPC 1 TBL 6.1.14.4.1. (B), the Building must be equipped with an approved Fire Sprinkler System in accordance with NFPA 13 Per 7th Edition FFPC 1, 6.1.14.4.3 and 7th Edition FFPC 101, 6.1.14.4.3 and must be supervised in accordance with 7th Edition FFPC 1, 13.3.1.8. (please provide details in code analysis indicating if the building is currently sprinklered or will be sprinklered to comply) 5. Please have the registered design professional (RDP) or owner classify the hazard of contents for review and approval on the basis of the character of the contents and the processes or operations conducted in the building or structure. FFPC 101, Life Safety Code 6.2.1.2 6. Please provide travel distance for Extinguishers not exceeding the limits of travel per FFPC 1, TABLES 13.6.3.2.1.1 & 13.6.3.3.1.1 According to Classification and type of Hazard. | |||
| BLD | HOLD | 05/16/2022 | 05/17/2022 |
| Note: Held By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM All comments below per the 2020 Florida Building Code REVIEW COMMENTS: Repeat Comment 1. OK 2. OK 3. Existing occupancy classification is noted as F-2 and Business. Provide what is being manufactured and if there is any storage occupancy. 4. Provide the existing type of building construction. Plans call-out existing without noting the existing building construction type. 5. Travel distance is noted 400 ft. Revise the travel distance to the most restrictive occupancy per Table 1017.2. 6. OK 7. The existing use is called-out as F-2 and B. The Life Safety Summary calls-out B and S-1. Revise to reflect the correct occupancy for the proposed tenant space. 8. OK 9. Revise Demo Notes to correlate to reflect the correct work to be performed. 10. Rollup door 001B is called-out. Opening Schedule dos not reflect the door. Door is part of a rated assemble. Door Types on sheet A3.0 do not match the call-outs on the Floor Plan and the Opening Schedule. Revise to reflect the correct doors are called-out. 11. Tenant Common Space has overhead doors. Provide clarity if this a shared Loading Dock or Lobby for the multiple tenant space. 12. Office Space for Unit #1 exit’s thru a common area. As mentioned above, the common area appears to be a load dock. The exit path puts restrictions on this area do to probability of obstruction to possible free egress path of travel. 1016.2 FBC 2020 13. Provide details for the proposed ADA concrete ramp and rails. Requirements per 405 2020 Florida Accessibility Code. 14. Provide calculations for ADA accessible spaces per 206, 2020 Florida Accessibility Code. 15. Provide interior wall and ceiling finish materials per 803.1.1 16. Sheet A2.01 was revised and submitted as Overall Building Plan. Previous sheet A2.01 is Demo Plan. Provide which is correct (New Comment) | |||
| PLUM | HOLD | 05/16/2022 | 05/17/2022 |
| Note: Held By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM All comments below per the 2020 Florida Building Code – Plumbing REVIEW COMMENTS: Repeat Comments 1. OK 2. Both occupancies called-out require a service sink. Table 403.1 | |||
| BLD | HOLD | 03/09/2022 | 03/23/2022 |
| Note: Held By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM All comments below per the 2020 Florida Building Code REVIEW COMMENTS: 1. Provide an over plan tenant layout plan. The plan is to show all spaces of the building and there use. 2. Provide a Code Analysis per the Existing Building Code. Provide the compliance method used. 3. Existing occupancy classification is noted as F-2 and Business. Provide what is being manufactured and if there is any storage occupancy. 4. Provide the existing type of building construction. Plans call-out existing without noting the existing building construction type. 5. Travel distance is noted 400 ft. Revise the travel distance to the most restrictive occupancy per Table 1017.2. 6. Dead End Corridor distance far exceeds the distance requirements per 1020.4. 7. The existing use is called-out as F-2 and B. The Life Safety Summary calls-out B and S-1. Revise to reflect the correct occupancy for the proposed tenant space. 8. Note under the Life Safety Summary reference the 2022 Building Code. As of January 1, 2021, Florida State adopted the 2020 Florida Building Codes. A revision to the note is required to reflect the correct Code cycle. 9. Revise Demo Notes to correlate to reflect the correct work to be performed. 10. Rollup door 001B is called-out. Opening Schedule dos not reflect the door. Door is part of a rated assemble. Door Types on sheet A3.0 do not match the call-outs on the Floor Plan and the Opening Schedule. Revise to reflect the correct doors are called-out. 11. Tenant Common Space has overhead doors. Provide clarity if this a shared Loading Dock or Lobby for the multiple tenant space. 12. Office Space for Unit #1 exit’s thru a common area. As mentioned above, the common area appears to be a load dock. The exit path puts restrictions on this area do to probability of obstruction to possible free egress path of travel. 1016.2 FBC 2020 13. Provide details for the proposed ADA concrete ramp and rails. Requirements per 405 2020 Florida Accessibility Code. 14. Provide calculations for ADA accessible spaces per 206, 2020 Florida Accessibility Code. 15. Provide interior wall and ceiling finish materials per 803.1.1 | |||
| DSD | COMPLETE | 03/09/2022 | 03/14/2022 |
| Note: Released By: JACQUELINE GONZALEZ - (386)986-3751 - JGONZALEZ@PALMCOASTGOV.COM | |||
| ELEC | HOLD | 03/09/2022 | 03/14/2022 |
| Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. Need to submit Electrical plans proposed and existing. 2. These were not tenant spaces before so you need to submit some kind of written response of what is going in these spots. 3. Tenants shall have ready access of the circuit breakers. NEC 2017 240.24 (B) 4. Submit a code analyst 5. Need to show the size of the services for each tenant. 6. Need to note if the generator is existing. If not submit manufacture specs on generator and a riser diagram. | |||
| FI1 | HOLD | 03/09/2022 | 03/23/2022 |
| Note: Held By: LEE MILLER - (386)986-3783 - WMILLER@PALMCOASTGOV.COM Please provide a written response to each comment below in a response letter and provide clouded response changes on plan sheets. 1. Provide code analysis using Chapter 7, Chapter 10 and Chapter 11 of the FBC Existing Building 2020 7th edition, FFPC 2020 7th edition, NFPA 10 (2018), NFPA 72 (2016), and NFPA 13 (2016) 2. Provide response detailing use of tenant spaces 3. Provide penetration details for fire resistive rated walls for copper linesets and drain lines per FBC Building 717.1.2 and 714.4.2 4. In order to take the reduction of Fire Separation Barrier between Storage and Business down to 1-Hour PER FFPC 1 TBL 6.1.14.4.1. (B), the Building must be equipped with an approved Fire Sprinkler System in accordance with NFPA 13 Per 7th Edition FFPC 1, 6.1.14.4.3 and 7th Edition FFPC 101, 6.1.14.4.3 and must be supervised in accordance with 7th Edition FFPC 1, 13.3.1.8. (please provide details in code analysis indicating if the building is currently sprinklered or will be sprinklered to comply) 5. Please have the registered design professional (RDP) or owner classify the hazard of contents for review and approval on the basis of the character of the contents and the processes or operations conducted in the building or structure. FFPC 101, Life Safety Code 6.2.1.2 6. Please provide travel distance for Extinguishers not exceeding the limits of travel per FFPC 1, TABLES 13.6.3.2.1.1 & 13.6.3.3.1.1 According to Classification and type of Hazard. | |||
| MECH | HOLD | 03/09/2022 | 03/18/2022 |
| Note: Held By: CHRIS PISCITELLI - (386)986-3782 - CPISCITELLI@PALMCOASTGOV.COM 1. Provide code analysis using Chapter 7, Chapter 10 and Chapter 11 of the FBC Existing Building 2020 7th edition 2. Provide responce detailing use of tenant spaces 3. Provide ventilation calculation for all spaces per M403.3.1.1 FBC Mechanical 2020 7th edition 4. Provide heatload calculation for all spaces per C403.2.1 FBC Energy Conservation 2020 7th edition 5. Provide Duct layout showing supply, return, fresh air, and exhaust. Include new and proposed changes 6. Provide penetration details for fire resistive rated walls for copper linesets and drain lines per FBC Building 717.1.2 and 714.4.2 7. Provide locations of all AHU's 8. Provide location of all thermostats | |||
| PLUM | HOLD | 03/09/2022 | 03/23/2022 |
| Note: Held By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM All comments below per the 2020 Florida Building Code – Plumbing REVIEW COMMENTS: 1. Provide fixture calculations for each space and based on each use. Section 403. 2. Both occupancies called-out require a service sink. Table 403.1 | |||
| UD1 | COMPLETE | 03/09/2022 | 03/09/2022 |
| Note: Released By: CHRIS JOHNSON - (386)986-2384 - CJOHNSON@PALMCOASTGOV.COM |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| ADJUSTMENT 50% | (¤913.63) | 08/26/2022 |
| ADMINISTRATIVE - COMMERCIAL | ¤75.00 | 08/26/2022 |
| INSPECTION COMMERCIAL | ¤1,505.00 | 08/26/2022 |
| PLAN REVIEW - COMMERCIAL | ¤247.25 | 08/26/2022 |
| SURCHARGE FS 533.721 | ¤9.68 | 08/26/2022 |
| SURCHARGE - FS 468.631 | ¤14.52 | 08/26/2022 |
| SITE PLAN 30 | ¤30.00 | 08/26/2022 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤967.82 |