Permit #2022030766
Permit Details
Status: FINAL
| Parcel Id: 07-11-31-7032-00510-0250 |
| Block: 00510 |
| Subdivision: 2155 - SECTION 32-ROYAL PALMS |
| Job Phone: 855-438-1515 |
| Location Address: 13 ROXTON LN |
| Type: SLRE - SOLAR ELECTRIC - PHOTOVOLTAIC |
| Issue Date: 03/21/2022 |
| NOC: RECORDED |
| Applicant name: DANIEL T WAGNER |
| Owner: BRITE LEGACY LLC |
|
Address 7345 GREENBRIAR PKWY ORLANDO, FL 32819 |
| Lot: 0250 |
| Contracted Stated Job Value: ¤14,307.23 |
| Job Description: PV Solar on roof |
| Type: CN |
Contractor
15 LIGHTYEARS INC
| Status | Location Address | Mailing Address | State License Number | Phone |
| INACTIVE |
776 BENNETT DR LONGWOOD, FL 32750 |
STE 101 LONGWOOD, FL 32750 |
EC13005084 (Exp: 08/31/2024) | 855-438-1515 |
Inspection History
| Type | Request Date | Result | Inspector |
| SOLAR ELECTRIC FINAL | 07/18/2022 | FINAL APPROVED | JWALKER |
| Note: THIS IS A REINSPECTION THIS IS A REINSPECTION THIS IS A REINSPECTION Missing screw in the dissconnect panel. The screw was remove to install the 30amp breaker and has not been reinstalled. The wiring that connect the panels on the roof are hanging down and need to be pulled off of the roof and supported to the rails properly.. This will allow proper water flow and prevent debris from getting hung up. NEC 110.12 12/13/22 Above listed corrections have not been made. Screw used in the panel is not the correct type of screw. Contractor asked to meet. Time was given 10:30 to 11 am. Contractor did not show up. | |||
| SOLAR ELECTRIC FINAL | 07/13/2022 | Disapproved -FEE REQUIRED | JWALKER |
| Note: THIS IS A REINSPECTION THIS IS A REINSPECTION Missing screw in the dissconnect panel. The screw was remove to install the 30amp breaker and has not been reinstalled. The wiring that connect the panels on the roof are hanging down and need to be pulled off of the roof and supported to the rails properly.. This will allow proper water flow and prevent debris from getting hung up. NEC 110.12 12/13/22 Above listed corrections have not been made. Screw used in the panel is not the correct type of screw. Contractor asked to meet. Time was given 10:30 to 11 am. Contractor did not show up. | |||
| SOLAR ELECTRIC FINAL | 07/08/2022 | Disapproved -FEE REQUIRED | JWALKER |
| Note: THIS IS A REINSPECTION Missing screw in the dissconnect panel. The screw was remove to install the 30amp breaker and has not been reinstalled. The wiring that connect the panels on the roof are hanging down and need to be pulled off of the roof and supported to the rails properly.. This will allow proper water flow and prevent debris from getting hung up. NEC 110.12 | |||
| SOLAR ELECTRIC FINAL | 05/23/2022 | Disapproved - NO FEE | JWALKER |
| Note: Missing screw in the dissconnect panel. The drawing are showing 22 Panels are to be installed. The wiring that connect the panels on the roof are hanging down and need to be pulled off of the roof and supported to the rails properly.. This will allow proper water flow and prevent devris from getting hung up. Panels have been installed in the 3' set back area Detail on PV2.1 of the prints. |
Review History
| Department | Status | Date In | Date Out |
| BLD | COMPLETE | 06/30/2022 | 07/01/2022 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| BLD | HOLD | 05/26/2022 | 05/26/2022 |
| Note: Held By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM All comments below per the 2020 Florida Building Code REVIEW COMMENTS: 1. Engineers digital signature could not be verified. Florida Administrative Code 61G15-23.001(1) 2. Engineer to provide compliance with section 324.6.1, R324.6.2 and R324.6.2.1 | |||
| BLD | COMPLETE | 04/06/2022 | 04/06/2022 |
| Note: Released By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM | |||
| ELEC | COMPLETE | 04/06/2022 | 04/06/2022 |
| Note: Released By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 03/18/2022 | 03/18/2022 |
| Note: Released By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM | |||
| BLD | HOLD | 03/14/2022 | 03/15/2022 |
| Note: Held By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM All comments below per the 2020 Florida Building Code – Residential REVIEW COMMENTS: 1. Provide 18 inch setback from ridge per R324.6.2 | |||
| ELEC | COMPLETE | 03/14/2022 | 03/14/2022 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| REINSPECTION RESIDENTIAL | ¤40.00 | 07/14/2022 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 07/08/2022 |
| SURCHARGE FS 533.721 | ¤2.00 | 03/21/2022 |
| SURCHARGE - FS 468.631 | ¤2.00 | 03/21/2022 |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | 03/21/2022 |
| INSPECTION - RESIDENTIAL | ¤60.00 | 03/21/2022 |
| SOLAR PLAN REVIEW | ¤65.00 | 03/21/2022 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤239.00 |