Permit #2022031177

Permit Details

Status: COED

Parcel Id: 07-11-31-7010-00110-0160
CONDITIONED SPACE: 2011 sqft
GARAGE: 498 sqft
OPENED PORCH (WITH ROOF) : 495 sqft
OPENED PORCH (WITH ROOF) : 118 sqft
Total Square Footage: 3122 sqft
Block: 00110
Subdivision: 2137 - SECTION 10-FLORIDA PARK
Job Phone: 386-931-6577
Location Address: 33 FIRCREST LN
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 04/20/2022
NOC: RECORDED
Applicant name: LUIS JORGE MEDEIROS
Owner: GOMES JOAO A & GUILHERNINA A H&W

Address

22 PRESTON LANE

PALM COAST, FL 32164

Lot: 0160
Contracted Stated Job Value: ¤239,280.00
Job Description: SINGLE FAMILY RESIDENCE
Type: CN

Contractor

A PLUS HOME IMPROVEMENTS LLC
Status Location Address State License Number Phone
ACTIVE

306 S RAILROAD ST

BUNNELL, FL 32110

CRC1327024 (Exp: 08/31/2026) 386-263-2167

Sub Contractors

FERNANDO M FARIA
Status Location Address State License Number Phone
ACTIVE

23 FREELAND LANE

PALM COAST, FL 32137

RF11067823 (Exp: 08/31/2027) 386-569-4336
JOSE E ORTIZ JR
Status Location Address Mailing Address State License Number Phone
CANCEL

4601 E MOODY BLVD

BUNNELL, FL 32110

SUITE B7

BUNNELL, FL 32110

RC29027619 (Exp: 08/31/2023) 386-503-6922
MIGUEL ANGEL GALLARDO
Status Location Address State License Number Phone
INACTIVE

315 PACER CT

SANFORD, FL 32773

CAC1813826 (Exp: 08/31/2026) 407-202-0953
JOSEPH MOUAG
Status Location Address State License Number Phone
ACTIVE

842 BANBURY DRIVE

PORT ORANGE, FL 32129

EC13006957 (Exp: 08/31/2026) 386-547-3722

Inspection History

Type Request Date Result Inspector
BLD - BUILDING FINAL 02/25/2025 FINAL APPROVED HCAMACHO
Note:
ROW - FINAL APRON (AFTER POUR) 02/25/2025 APPROVED PFLANAGAN
Note: At the time of the inspection all minimum city requirements were met. It is the builders and the homowners responsibility to ensure that nothing changes after this Inspection is approved. It will not be on the city if any changes after this inspection.
ROW - STORMWATER FINAL 02/25/2025 APPROVED PFLANAGAN
Note: TALKED TO LEWIS ABOUT REMOVING SOME DIRT FROM THE CULVERT PIPE AND THE ROOF SHINGLES IN THE BACK
U -UTILITY RESIDENTIAL FINAL 02/25/2025 FINAL APPROVED LFITZGERALD
Note: Inspector Notes from Inspection 9035 *** NOTES ADDED BY LFITZGERALD 12/10/2024 11:26:53 AM *** no irrigation-no cross connection
ROW FIELD SURVEY /GRADING CERTIFICATION 02/18/2025 APPROVED - AS NOTED PFLANAGAN
Note: SEE NOTES ON FINAL SURVEY IF ANY QUESTIONS. ----------------------------------------------------------------------- 1/31/2025 - PREVIOUS INSPECTION NOTES ** 01/31/25 BUILDER SUBMITTED FOR A FIELD SURVEY INSPECTION / INSPECTOR CONDUCTED THE FINAL SURVEY AS DISCUSSED WITH BUILDER ON 01/30/25 AS YOU HAD UPLOADED AS A REVISED SITE PLAN AND WAS INTENDED TO BE FOR FINAL SURVEY. ** SEE NOTES IN FINAL SURVEY AS YOUR FINAL SURVEY DOES NOT REFLECT WHATS IN THE FIELD AT THE TIME OF THE INSPECTION NEED TO CORRRECT SITE CONDITIONS AND SUBMIT A NEW FINAL SURVEY _________________________________________________________________________________________________________________ 1/30/2025 - PREVIOUS INSPECTION NOTES ** 01/30/25 BUILDER NEEDS HAVE AN APPROVED FINAL SURVEY BEFORE A FIELD SURVEY CAN BE CONDUCTED
ROW- FINAL SURVEY/GRADING CERTIFICATION 02/18/2025 APPROVED - AS NOTED PFLANAGAN
Note: CORRECTIONS MADE TO THE FIELD SO WATER WILL NOT HOLD ON RIGHT SIDE OF HOUSE AND THE LEFT AND RIGHT RIGHT OF WAY LINE IS EQUAL OR GREATER THEN EDGE OF ROAD. ------------------------------------------------------------------ 1/31/2025 - PREVIOUS INSPECTION NOTES ** 01/31/25 FINAL SURVEY DOES NOT REFLECT WHAT IS IN THE FIELD ** LEFT SIDE FRONT PROPERTY LINE IS LOWER THAN THE EDGE OF ROAD ** RIGHT REAR CORNER OF STRUCTURE LOW AREA WILL HOLD WATER NEED TO HAVE POSITIVE FLOW TO THE FRONT ** RIGHT FRONT CORNER PROPERTY LINE EED TO BRING DRAINAGE AROUND THE INSIDE OF UTILITY BOX ____________________________________________________________________________________________________________________ 1/3/2025 - PREVIOUS INSPECTION NOTES 1/3/25= The subject lots drainage must not negatively impact any adjacent property. WATER WILL AFFECT THE NEIGHBORING HOUSES ON BOTH SIDES; PLEASE CHECK THE FINAL SURVEY FOR REMARKS. please check the FINAL SURVEY FOR REMARKS. SITE PLAN SHOULD ONLY ONE CULVERT PIPE, WHILE THE SWALE PLAN SHOULD TWO CULVERT PIPES. ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ ** 06/11/24 CORRECTIONS MADE READY TO POUR ** At the time of the inspection all minimum city requirements were met. It is the builders responsibility to ensure that nothing changes after this Inspection is approved. This includes but is not limited to, the Culvert Pipe Elevation from the time of the inspection approval to the concrete pour. **MAKE SURE THERE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL ___________________________________________________________________________________________________________________ 6/10/2024 - PREVIOUS INSPECTION NOTES ** 06/07/24 BUILDER NEEDS TO EXTEND FORM BOARDS OR BACK FILL TO CONTAIN THE CONCRETE WITHIN THE POUR AREA ** ENSURE YOU HAVE 6 INCHS IN APRON POUR AREA OU TO EDGE OF ROADWAY
ROW- PROJECT STATUS 02/06/2025 Status Check PFLANAGAN
Note: MEET WITH ROBERT AND LUIS 930AM
ROW- FINAL SURVEY/GRADING CERTIFICATION 01/31/2025 Disapproved -FEE REQUIRED EMADISON
Note: ** 01/31/25 FINAL SURVEY DOES NOT REFLECT WHAT IS IN THE FIELD ** LEFT SIDE FRONT PROPERTY LINE IS LOWER THAN THE EDGE OF ROAD ** RIGHT REAR CORNER OF STRUCTURE LOW AREA WILL HOLD WATER NEED TO HAVE POSITIVE FLOW TO THE FRONT ** RIGHT FRONT CORNER PROPERTY LINE EED TO BRING DRAINAGE AROUND THE INSIDE OF UTILITY BOX ____________________________________________________________________________________________________________________ 1/3/2025 - PREVIOUS INSPECTION NOTES 1/3/25= The subject lots drainage must not negatively impact any adjacent property. WATER WILL AFFECT THE NEIGHBORING HOUSES ON BOTH SIDES; PLEASE CHECK THE FINAL SURVEY FOR REMARKS. please check the FINAL SURVEY FOR REMARKS. SITE PLAN SHOULD ONLY ONE CULVERT PIPE, WHILE THE SWALE PLAN SHOULD TWO CULVERT PIPES. ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ ** 06/11/24 CORRECTIONS MADE READY TO POUR ** At the time of the inspection all minimum city requirements were met. It is the builders responsibility to ensure that nothing changes after this Inspection is approved. This includes but is not limited to, the Culvert Pipe Elevation from the time of the inspection approval to the concrete pour. **MAKE SURE THERE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL ___________________________________________________________________________________________________________________ 6/10/2024 - PREVIOUS INSPECTION NOTES ** 06/07/24 BUILDER NEEDS TO EXTEND FORM BOARDS OR BACK FILL TO CONTAIN THE CONCRETE WITHIN THE POUR AREA ** ENSURE YOU HAVE 6 INCHS IN APRON POUR AREA OU TO EDGE OF ROADWAY
ROW FIELD SURVEY /GRADING CERTIFICATION 01/31/2025 Disapproved - NO FEE EMADISON
Note: ** 01/31/25 BUILDER SUBMITTED FOR A FIELD SURVEY INSPECTION / INSPECTOR CONDUCTED THE FINAL SURVEY AS DISCUSSED WITH BUILDER ON 01/30/25 AS YOU HAD UPLOADED AS A REVISED SITE PLAN AND WAS INTENDED TO BE FOR FINAL SURVEY. ** SEE NOTES IN FINAL SURVEY AS YOUR FINAL SURVEY DOES NOT REFLECT WHATS IN THE FIELD AT THE TIME OF THE INSPECTION NEED TO CORRRECT SITE CONDITIONS AND SUBMIT A NEW FINAL SURVEY _________________________________________________________________________________________________________________ 1/30/2025 - PREVIOUS INSPECTION NOTES ** 01/30/25 BUILDER NEEDS HAVE AN APPROVED FINAL SURVEY BEFORE A FIELD SURVEY CAN BE CONDUCTED
ROW FIELD SURVEY /GRADING CERTIFICATION 01/30/2025 Disapproved -FEE REQUIRED EMADISON
Note: ** 01/30/25 BUILDER NEEDS HAVE AN APPROVED FINAL SURVEY BEFORE A FIELD SURVEY CAN BE CONDUCTED
ROW- FINAL SURVEY/GRADING CERTIFICATION 01/03/2025 Disapproved - NO FEE GBERTOLA
Note: 1/3/25= The subject lots drainage must not negatively impact any adjacent property. WATER WILL AFFECT THE NEIGHBORING HOUSES ON BOTH SIDES; PLEASE CHECK THE FINAL SURVEY FOR REMARKS. please check the FINAL SURVEY FOR REMARKS. SITE PLAN SHOULD ONLY ONE CULVERT PIPE, WHILE THE SWALE PLAN SHOULD TWO CULVERT PIPES. ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ ** 06/11/24 CORRECTIONS MADE READY TO POUR ** At the time of the inspection all minimum city requirements were met. It is the builders responsibility to ensure that nothing changes after this Inspection is approved. This includes but is not limited to, the Culvert Pipe Elevation from the time of the inspection approval to the concrete pour. **MAKE SURE THERE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL ___________________________________________________________________________________________________________________ 6/10/2024 - PREVIOUS INSPECTION NOTES ** 06/07/24 BUILDER NEEDS TO EXTEND FORM BOARDS OR BACK FILL TO CONTAIN THE CONCRETE WITHIN THE POUR AREA ** ENSURE YOU HAVE 6 INCHS IN APRON POUR AREA OU TO EDGE OF ROADWAY
U-CROSS CONNECTION 12/10/2024 CANCELLED BY APPLICANT WEB
U-CROSS CONNECTION 12/10/2024 APPROVED - AS NOTED LFITZGERALD
Note: *** NOTES ADDED BY LFITZGERALD 12/10/2024 11:26:53 AM *** no irrigation-no cross connection
FINAL SURVEY (OFFICE USE ONLY) 12/09/2024 Disapproved - NO FEE EMADISON
Note: ** 12/09/24 CULVERT PIPE LEFT SIDE IS OUT OF TOLERANCE IN ACCORDANCE TO THE SWALE PLAN DIAGRAM ** Swale Plan #1. The driveway culvert inverts are to be installed within 0.1' (+/-) of the elevations indicated on the swale plan (unless otherwise approved by the City StormwaterEngineer). The finished swale elevation is with sod in place
ROW- PRE-APRON (PRE-POUR) 06/11/2024 APPROVED - AS NOTED EMADISON
Note: ** 06/11/24 CORRECTIONS MADE READY TO POUR ** At the time of the inspection all minimum city requirements were met. It is the builders responsibility to ensure that nothing changes after this Inspection is approved. This includes but is not limited to, the Culvert Pipe Elevation from the time of the inspection approval to the concrete pour. **MAKE SURE THERE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL ___________________________________________________________________________________________________________________ 6/10/2024 - PREVIOUS INSPECTION NOTES ** 06/07/24 BUILDER NEEDS TO EXTEND FORM BOARDS OR BACK FILL TO CONTAIN THE CONCRETE WITHIN THE POUR AREA ** ENSURE YOU HAVE 6 INCHS IN APRON POUR AREA OU TO EDGE OF ROADWAY
ROW- PRE-APRON (PRE-POUR) 06/10/2024 Disapproved - NO FEE EMADISON
Note: ** 06/07/24 BUILDER NEEDS TO EXTEND FORM BOARDS OR BACK FILL TO CONTAIN THE CONCRETE WITHIN THE POUR AREA ** ENSURE YOU HAVE 6 INCHS IN APRON POUR AREA OU TO EDGE OF ROADWAY
ELECTRIC - EARLY POWER 06/04/2024 APPROVED JWALKER
Note: 4/25/2024 - PREVIOUS INSPECTION NOTES Bathroom light wiring has not been safed off in both bathrooms.
ELECTRIC - EARLY POWER 04/25/2024 Disapproved - NO FEE JWALKER
Note: Bathroom light wiring has not been safed off in both bathrooms.
GRAVITY SEWER TEST 04/17/2024 APPROVED JSTEWART
U - SEWER TIE IN 04/17/2024 APPROVED JSTEWART
INSULATION 12/18/2023 APPROVED - AS NOTED AGAETANO
Note: 12-18-2023 Please insulate garage entry door jambs prior to drywall installation.
LATH/BRICK/ WATER BARRIER 12/11/2023 APPROVED BTAYLOR
ALL ROUGH 12/08/2023 APPROVED BTAYLOR
Note: 12/4/2023 - PREVIOUS INSPECTION NOTES 12-04-2023 1. Exterior outlets grounds not connected. 2. Dryer vent not per code and cannot be sloped downward. 3. Dryer vent mssing shield plates. 4. Wires not phased out. 5. Kitchen vent not sealed at roof deck. 6. No head test. 7. Mechanical layout not on site. 8. Energy calcs permit number is faded. Please have a readable set of approved drawings and documents on site. Inspection stopped.
ALL ROUGH 12/04/2023 Disapproved - NO FEE AGAETANO
Note: 12-04-2023 1. Exterior outlets grounds not connected. 2. Dryer vent not per code and cannot be sloped downward. 3. Dryer vent mssing shield plates. 4. Wires not phased out. 5. Kitchen vent not sealed at roof deck. 6. No head test. 7. Mechanical layout not on site. 8. Energy calcs permit number is faded. Please have a readable set of approved drawings and documents on site. Inspection stopped.
WALL SHEATHING 12/01/2023 APPROVED FWILLIS
ROOF SHEATHING / BRACES/TIES/DOWN CELL 11/30/2023 APPROVED FWILLIS
Note: 06/21/2023- Roof sheathing has been checked 5/3/2023 - PREVIOUS INSPECTION NOTES Inspector Notes from Inspection 2340 11/4/2022 - PREVIOUS INSPECTION NOTES 11/2/2022 - PREVIOUS INSPECTION NOTES 11-02-2022 Foundation plan not on site as well as other mssing sheet. Please provide a full set of approved drawing for inspection. NEED THE APPROVED DOCUMENTS ON SITE FOR INSPECTION 107.3,1. 11-04-2022 SD2 1F indicates rebar top and bottom of lintel. Missing rebar at lanai lintel. Check all. 11-21-2022 Drawings are wet. Please provide a full set of approved drawings for all future inspections to aviod any fees. 05-02-2023 1. SD2 Typical frame to block wall attachment not installed as per plans. 2. Please indicate the interior bearing walls on the drawings. 3. Multiple shiners at garage at over framing. Check all areas. 4. Piggyback trusses not installed as per details.
ROOF VALLEY & METAL 06/22/2023 APPROVED AGAETANO
Note: Inspector Notes from Inspection 2465 06/21/2023-This does not allow house to be shingled prior to tie down inspection
ROOF SHEATHING 06/21/2023 APPROVED - AS NOTED TSTAUFFACHER
Note: 06/21/2023-This does not allow house to be shingled prior to tie down inspection
DOWN CELL 05/15/2023 APPROVED AGAETANO
ROOF SHEATHING / BRACES/TIES/DOWN CELL 05/03/2023 Disapproved - NO FEE AGAETANO
Note: Inspector Notes from Inspection 2340 11/4/2022 - PREVIOUS INSPECTION NOTES 11/2/2022 - PREVIOUS INSPECTION NOTES 11-02-2022 Foundation plan not on site as well as other mssing sheet. Please provide a full set of approved drawing for inspection. NEED THE APPROVED DOCUMENTS ON SITE FOR INSPECTION 107.3,1. 11-04-2022 SD2 1F indicates rebar top and bottom of lintel. Missing rebar at lanai lintel. Check all. 11-21-2022 Drawings are wet. Please provide a full set of approved drawings for all future inspections to aviod any fees. 05-02-2023 1. SD2 Typical frame to block wall attachment not installed as per plans. 2. Please indicate the interior bearing walls on the drawings. 3. Multiple shiners at garage at over framing. Check all areas. 4. Piggyback trusses not installed as per details.
TIE BEAM / LINTEL 11/21/2022 APPROVED - AS NOTED AGAETANO
Note: 11/4/2022 - PREVIOUS INSPECTION NOTES 11/2/2022 - PREVIOUS INSPECTION NOTES 11-02-2022 Foundation plan not on site as well as other mssing sheet. Please provide a full set of approved drawing for inspection. NEED THE APPROVED DOCUMENTS ON SITE FOR INSPECTION 107.3,1. 11-04-2022 SD2 1F indicates rebar top and bottom of lintel. Missing rebar at lanai lintel. Check all. 11-21-2022 Drawings are wet. Please provide a full set of approved drawings for all future inspections to aviod any fees.
TIE BEAM / LINTEL 11/04/2022 Disapproved -FEE REQUIRED AGAETANO
Note: 11/2/2022 - PREVIOUS INSPECTION NOTES 11-02-2022 Foundation plan not on site as well as other mssing sheet. Please provide a full set of approved drawing for inspection. NEED THE APPROVED DOCUMENTS ON SITE FOR INSPECTION 107.3,1. 11-04-2022 SD2 1F indicates rebar top and bottom of lintel. Missing rebar at lanai lintel. Check all.
TIE BEAM / LINTEL 11/02/2022 Disapproved -FEE REQUIRED AGAETANO
Note: 11-02-2022 Foundation plan not on site as well as other mssing sheet. Please provide a full set of approved drawing for inspection. NEED THE APPROVED DOCUMENTS ON SITE FOR INSPECTION 107.3,1.
FOUND SURVEY APPROVED (OFFICE) 08/25/2022 APPROVED TBAKER
MONOLITHIC SLAB 08/09/2022 APPROVED LMILLER
PLUMBING 1ST ROUGH UNDERGROUND 07/05/2022 APPROVED MGIBSON
WATER METER INSTALLATION REQUEST 05/02/2022 APPROVED CSTONE

Review History

Department Status Date In Date Out
ENGIN1 COMPLETE 01/22/2025 01/28/2025
Note: Released By: RODNEY RICKS - - RRICKS@PALMCOASTGOV.COM
MECH COMPLETE 01/22/2025 01/27/2025
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
SW1 COMPLETE 01/22/2025 01/28/2025
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
ZON COMPLETE 01/22/2025 01/22/2025
Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM
ZON COMPLETE 11/20/2024 11/20/2024
Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM
ENGIN1 COMPLETE 03/06/2024 03/06/2024
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
ZON COMPLETE 03/06/2024 03/06/2024
Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM
SW1 COMPLETE 03/06/2024 03/06/2024
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
ENGIN1 COMPLETE 08/25/2022 08/25/2022
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
ZON COMPLETE 08/25/2022 08/25/2022
Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM
BLD COMPLETE 04/20/2022 04/20/2022
Note: Released By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM
ZON COMPLETE 04/19/2022 04/20/2022
Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM
MECH COMPLETE 04/19/2022 04/20/2022
Note: Released By: CHRIS PISCITELLI - (386)986-3782 - CPISCITELLI@PALMCOASTGOV.COM
BLD HOLD 04/19/2022 04/20/2022
Note: Held By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM
MECH HOLD 04/04/2022 04/04/2022
Note: Held By: CHRIS PISCITELLI - (386)986-3782 - CPISCITELLI@PALMCOASTGOV.COM 1. Design location on heatload needs to match the energy calc location (Daytona Beach) 2. Provide duct layout signed by the AC contractor (Second Request) 3. Square footage on Energy Calcs does not match the plans
ZON HOLD 04/04/2022 04/04/2022
Note: Held By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM Plantings must wrap both corners with four along each front side Plantings on the sides and rear do not count for the four. So you need three more on each side.
ELEC COMPLETE 04/04/2022 04/04/2022
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
BLD HOLD 04/04/2022 04/04/2022
Note: Held By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM Product approval specification sheet per F.S. 553.842: Provide product approval for wood anchors.
SWALE COMPLETE 03/29/2022 06/06/2022
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
BLD HOLD 03/24/2022 03/25/2022
Note: Held By: FRED REODICA - (386)986-4734 - FREODICA@PALMCOASTGOV.COM Product approval specification sheet per F.S. 553.842: Provide product approval for wood anchors. The FL number 10446 - R6 is for wood connectors not wood anchors.
CUSVC COMPLETE 03/24/2022 03/29/2022
Note: Released By: ALYSSA ROSCOE - -
ELEC HOLD 03/24/2022 03/25/2022
Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. Need to reference the 2017 NEC not the 2020 2. Need to know the square footage of the house to match up with the load calcs.
ENGIN1 COMPLETE 03/24/2022 03/29/2022
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
LOCATE COMPLETE 03/24/2022 03/28/2022
Note: Released By: CANDACE STONE - - CSTONE@PALMCOASTGOV.COM
MECH HOLD 03/24/2022 03/25/2022
Note: Held By: CHRIS PISCITELLI - (386)986-3782 - CPISCITELLI@PALMCOASTGOV.COM 1. Design location on heatload needs to match the energy calc location (Daytona Beach) 2. Provide duct layout signed by the AC contractor 3. Provide floor plan showing square footage 4. Plans show R5 insulation on block walls. Energy Calcs show R4.1. Revise to match
SW1 COMPLETE 03/24/2022 03/28/2022
Note: Released By: PARREN FLANAGAN - - PFLANAGAN@PALMCOASTGOV.COM
ZON HOLD 03/24/2022 03/25/2022
Note: Held By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM Do not see square foot area calculations on plans Must have at least one shade tree Foundation plantings must be planted at least 2-8ft of the foundation of home not the walkway Plantings must wrap both corners with four along each side

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
PLAN REVIEW - REVISION ¤32.50 03/07/2025
REINSPECTION RESIDENTIAL ¤40.00 03/07/2025
REINSPECTION RESIDENTIAL ¤40.00 03/07/2025
CONTRACTOR CHANGE ¤20.00 03/07/2025
CONTRACTOR CHANGE ¤20.00 03/07/2025
IMPACT FEE FIRE ¤388.65 03/07/2025
IMPACT FEE PARKS ¤1,455.13 03/07/2025
IMPACT FEE TRANSPORTATION ¤1,764.00 03/07/2025
SW ENG REINSPECTION 20 ¤20.00 03/07/2025
SW ENG - REVIEW 20 ¤20.00 04/20/2022
SW ENG RES REVIEW 200 ¤200.00 04/20/2022
SEWER CREDIT (¤37.12) 04/20/2022
SEWER INSPECTION ¤25.00 04/20/2022
SEWER CAPITAL FACILITY ¤4,939.76 04/20/2022
WATER CAPITAL FACILITY FEE ¤3,626.50 04/20/2022
SITE PLAN 30 ¤30.00 04/20/2022
WATER -IRRIGATION INSPECTION ¤25.00 04/20/2022
SURCHARGE FS 533.721 ¤10.35 04/20/2022
SURCHARGE - FS 468.631 ¤15.53 04/20/2022
SW ENG - FOUNDATION SURVEY ¤20.00 04/20/2022
SW ENG INSPECTION 80 ¤80.00 04/20/2022
SW ENG PRE APRON ¤30.00 04/20/2022
IMPACT FEE SCHOOL ¤3,600.00 04/20/2022
CONNECTION FEES ¤1,077.88 04/20/2022
WATER- TURN ON ¤25.00 04/20/2022
ADMINISTRATIVE RESIDENTIAL ¤30.00 04/20/2022
INSPECTION - RESIDENTIAL ¤739.75 04/20/2022
PLAN REVIEW - RESIDENTIAL ¤209.82 04/20/2022
Fees Total Due: ¤0.00 Total Paid: ¤18,447.75