Permit #2022031226
Permit Details
Status: COED
| Parcel Id: 07-11-31-7034-01420-0110 |
| CONDITIONED SPACE: 1966 sqft |
| GARAGE: 685 sqft |
| OPENED PORCH (WITH ROOF) : 361 sqft |
| OPENED PORCH (WITH ROOF) : 182 sqft |
| Total Square Footage: 3194 sqft |
| Block: 01420 |
| Subdivision: 2165 - SECTION 34-EASTHAMPTON |
| Job Phone: (386)931-0785 |
| Location Address: 76 EDITH POPE DR |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 07/06/2022 |
| NOC: RECORDED |
| Applicant name: ROY CHARLES WALDHAUER |
| Owner: FAY TAMI & BY THE SHORE INC |
|
Address 29 EDGELY LANE PALM COAST, FL 32164 |
| Lot: 0110 |
| Contracted Stated Job Value: ¤275,000.00 |
| Job Description: SINGLE FAMILY RESIDENCE |
| Type: CN |
Contractor
BY THE SHORE INC.
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
1600 N STATE STREET # 102 , |
CRC1327300 (Exp: 08/31/2026) | 386-263-8272 | 386-263-8289 |
Sub Contractors
THOMAS A REGULA
| Status | Location Address | State License Number | Phone | Fax |
| INACTIVE |
11320 PHILLIPS PKWY DRIVE E JACKSONVILLE, FL 32256 |
CMC1250075 (Exp: 08/31/2026) | 904-278-0339 | 904-278-0366 |
DANIEL DAVID RUTKOWSKI III
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
1687 STATE AVENUE HOLLY HILL, FL 32117 |
CCC1328639 (Exp: 08/31/2026) | 386-290-7490 | 386-256-0001 |
WILLIAM FRANK DUDLEY JR.
| Status | Location Address | State License Number | Phone |
| ACTIVE |
P.O. BOX 978 Bunnell, FL 32110 |
EC0003177 (Exp: 08/31/2026) | (386)437-3068 |
GLEN WILLIAM KEHLE
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
P. O. Box 353511 BUNNELL, FL 32110 |
CFC057241 (Exp: 08/31/2026) | (386) 447-4249 | (386) 437-8488 |
Inspection History
| Type | Request Date | Result | Inspector |
| BLD - BUILDING FINAL | 09/20/2023 | APPROVED | RSIMS |
| Note: 9/11/2023 - PREVIOUS INSPECTION NOTES 9/11/23: 1). Range anti-tip device not installed. 2). Kitchen Microwave exhaust vent is not firestop sealed at the top of the cabinet going into pipe chase. (Chase prevents visual verification of sealing at ceiling drywall as required.). 3). AHU does not have the heater core/breaker sticker on the unit (FBC1303.1) 4). Attic pull down stairs- first step is over the 12" maximum spacing. 5). Outlet next to ODU is loose in the box. 6). AC condenser breaker is incorrect size as identified on the panel schedule. 7). Interior garage door is missing the door seal on left & top jamb. 3/20/23: Need revision submitted to & approved by the City for the different shingles (CertainTeed - Landmark) loaded on the roof than what was originally submitted (Owens Corning) before Building Final can be approved. 8/1/23: Note: Master bathroom closet switch is behind the door. Check for correction at building final. | |||
| BLD - BUILDING FINAL | 09/11/2023 | Disapproved -FEE REQUIRED | RSIMS |
| Note: 9/11/23: 1). Range anti-tip device not installed. 2). Kitchen Microwave exhaust vent is not firestop sealed at the top of the cabinet going into pipe chase. (Chase prevents visual verification of sealing at ceiling drywall as required.). 3). AHU does not have the heater core/breaker sticker on the unit (FBC1303.1) 4). Attic pull down stairs- first step is over the 12" maximum spacing. 5). Outlet next to ODU is loose in the box. 6). AC condenser breaker is incorrect size as identified on the panel schedule. 7). Interior garage door is missing the door seal on left & top jamb. 3/20/23: Need revision submitted to & approved by the City for the different shingles (CertainTeed - Landmark) loaded on the roof than what was originally submitted (Owens Corning) before Building Final can be approved. 8/1/23: Note: Master bathroom closet switch is behind the door. Check for correction at building final. | |||
| ROW - FINAL APRON (AFTER POUR) | 09/06/2023 | APPROVED | PFLANAGAN |
| Note: At the time of the inspection all minimum city requirements were met. It is the builders responsibiliy to ensure that nothing changes after this Inspection is approved. | |||
| ROW - STORMWATER FINAL | 09/06/2023 | FINAL APPROVED | PFLANAGAN |
| Note: At the time of the inspection all minimum city requirements were met. It is the builders responsibiliy to ensure that nothing changes after this Inspection is approved. | |||
| U -UTILITY RESIDENTIAL FINAL | 09/06/2023 | FINAL APPROVED | JHARDING |
| ROW- PROJECT STATUS | 08/25/2023 | APPROVED | PFLANAGAN |
| Note: MEET WITH THE CONTRACTOR ABOUT DRAINAGE | |||
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 08/25/2023 | APPROVED - AS NOTED | PFLANAGAN |
| Note: THE DRAINAGE ON THE LEFT OF THE PROPERTY LINE IS INSIDE THERE LOT AND CATCHING ALL STORMWATER FROM HOUSE 78 SO IT IS SHARING A COMMON SWALE -------------------------------------------------------------------------- 7/31/2023 - PREVIOUS INSPECTION NOTES THE DRAINAGE PATTERN ON THE LEFT SIDE NEEDS TO HAVE A COMMON SWALE DO TO THE NEW CONSTRUCTION TO THE LEFT OF YOUR LOT. | |||
| ROW FIELD SURVEY /GRADING CERTIFICATION | 08/25/2023 | APPROVED | PFLANAGAN |
| Note: Inspector Notes from Inspection 9463 THE DRAINAGE ON THE LEFT OF THE PROPERTY LINE IS INSIDE THERE LOT AND CATCHING ALL STORMWATER FROM HOUSE 78 SO IT IS SHARING A COMMON SWALE -------------------------------------------------------------------------- 7/31/2023 - PREVIOUS INSPECTION NOTES THE DRAINAGE PATTERN ON THE LEFT SIDE NEEDS TO HAVE A COMMON SWALE DO TO THE NEW CONSTRUCTION TO THE LEFT OF YOUR LOT. | |||
| ELECTRIC - EARLY POWER | 08/02/2023 | APPROVED | RSIMS |
| Note: 8/2/23: FPL emailed to release power. 8/1/2023 - PREVIOUS INSPECTION NOTES 8/1/23: ** Service feeds need to be tied in for Overhead Power (only). Note: Master bathroom closet switch is behind the door. Check for correction at building final. | |||
| ELECTRIC - EARLY POWER | 08/01/2023 | Disapproved - NO FEE | RSIMS |
| Note: 8/1/23: ** Service feeds need to be tied in for Overhead Power (only). Note: Master bathroom closet switch is behind the door. Check for correction at building final. | |||
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 07/31/2023 | Disapproved - NO FEE | PFLANAGAN |
| Note: THE DRAINAGE PATTERN ON THE LEFT SIDE NEEDS TO HAVE A COMMON SWALE DO TO THE NEW CONSTRUCTION TO THE LEFT OF YOUR LOT. | |||
| U-CROSS CONNECTION | 07/26/2023 | APPROVED - AS NOTED | JHARDING |
| Note: No cross connections. | |||
| ROW- PRE-APRON (PRE-POUR) | 06/28/2023 | APPROVED | PFLANAGAN |
| Note: IT'S YOUR RESPONSIBILITY TO CHECK THE CULVERT PIPE ELEVATIONS BEFORE POURING CONCRETE FOR DRIVEWAY ALL CONCRETE NEEDS TO BE A MINIMUM OF 3000PSI WITH FIBER OR WITH METAL MESH IN DRIVEWAY At the time of the inspection all minimum city requirements were met. It is the builders responsibiliy to ensure that nothing changes after this Inspection is approved. ----------------------------------------------------------------------------------------------------------- 6/27/2023 - PREVIOUS INSPECTION NOTES 1) SOIL BEHIND THE CULVERT IS TO SOFT NEED TO COMPACT SOIL MORE 2) WITH RAIN DIRT HAS WASHED UP AGAINST THE CULVERT NEED TO DIG DIRT THAT WASHED TO CULVERT | |||
| ROW- PRE-APRON (PRE-POUR) | 06/27/2023 | Disapproved -FEE REQUIRED | PFLANAGAN |
| Note: 1) SOIL BEHIND THE CULVERT IS TO SOFT NEED TO COMPACT SOIL MORE 2) WITH RAIN DIRT HAS WASHED UP AGAINST THE CULVERT NEED TO DIG DIRT THAT WASHED TO CULVERT | |||
| U - SEWER TIE IN | 06/27/2023 | APPROVED | MGIBSON |
| GRAVITY SEWER TEST | 06/27/2023 | APPROVED | MGIBSON |
| PEP TANK INSTALLATION REQUEST | 05/25/2023 | APPROVED | CSTONE |
| Note: 5/1/2023 11:34:07 AM- PREVIOUS INSPECTION NOTES Not ready- Exterior, Interior, Dumspter Stucco, Drywall, Siding etc need to be done. Dumpster will need to move | |||
| LATH/BRICK/ WATER BARRIER | 05/12/2023 | APPROVED | JWALKER |
| Note: 5/9/2023 - PREVIOUS INSPECTION NOTES 5/9/23: Left side of house-Penetrations into CMU wall require wire lath. Including at Lineset penetration. (foam alone is not approved.) | |||
| LATH/BRICK/ WATER BARRIER | 05/09/2023 | Disapproved - NO FEE | RSIMS |
| Note: 5/9/23: Left side of house-Penetrations into CMU wall require wire lath. Including at Linest penetration. (foam along is not approved.) | |||
| PEP TANK INSTALLATION REQUEST | 04/28/2023 | Disapproved - NO FEE | CSTONE |
| Note: Not ready- Exterior, Interior, Dumspter Stucco, Drywall, Siding etc need to be done. Dumpster will need to move | |||
| INSULATION | 04/25/2023 | APPROVED | RSIMS |
| Note: 4/24/2023 - PREVIOUS INSPECTION NOTES 4/24/23: Still have incomplete firestop at two locations. Added FS on the floor for easier identification. * Master bathroom at top plate penetration for water pipe. (behind nail plate). * Front right bedroom entry at top plate for wires groups at both penetrations. 4/21/2023 - PREVIOUS INSPECTION NOTES 4/21/23: Marked on wall/stud with FS in blue marker below areas. 1). Missing fireblocking/firestop at top plate area of front entry column. 2). Missing/incomplete firestop at 4 locations inside the house. (2 on left side and 2 on right side). 3). Incomplete firestop at top plate in garage for dryer exhaust & PVC vent stack. | |||
| INSULATION | 04/24/2023 | Disapproved - NO FEE | RSIMS |
| Note: 4/24/23: Still have incomplete firestop at two locations. Added FS on the floor for easier identification. * Master bathroom at top plate penetration for water pipe. (behind nail plate). * Front right bedroom entry at top plate for wires groups at both penetrations. 4/21/2023 - PREVIOUS INSPECTION NOTES 4/21/23: Marked on wall/stud with FS in blue marker below areas. 1). Missing fireblocking/firestop at top plate area of front entry column. 2). Missing/incomplete firestop at 4 locations inside the house. (2 on left side and 2 on right side). 3). Incomplete firestop at top plate in garage for dryer exhaust & PVC vent stack. | |||
| INSULATION | 04/21/2023 | Disapproved - NO FEE | RSIMS |
| Note: 4/21/23: Marked on wall/stud with FS in blue marker below areas. 1). Missing fireblocking/firestop at top plate area of front entry column. 2). Missing/incomplete firestop at 4 locations inside the house. (2 on left side and 2 on right side). 3). Incomplete firestop at top plate in garage for dryer exhaust & PVC vent stack. | |||
| ALL ROUGH | 04/14/2023 | APPROVED | KSANDOE |
| Note: Inspector Notes from Inspection 2467 3/20/23: Need revision submitted to & approved by the City for the different shingles (CertainTeed - Landmark) loaded on the roof than what was originally submitted (Owens Corning) before Building Final can be approved. 3/16/2023 - PREVIOUS INSPECTION NOTES 3/15/23: Previously listed deficiency is not resolved. Flashing cannot run across the valley because there is no effective way to seal the area from wind blown rain and/or rodents (G2402.9) 3/14/2023 - PREVIOUS INSPECTION NOTES 3/14/23: Please have Porta John moved from the adjacent swale of the adjacent private property to the building site. 1). 5" x 5" flashing at front entry is installed incorrectly. Flashing must run up the length of the vertical wall and be sealed to the wall as required. | |||
| ROOF VALLEY & METAL | 03/20/2023 | APPROVED - AS NOTED | RSIMS |
| Note: 3/20/23: Need revision submitted to & approved by the City for the different shingles (CertainTeed - Landmark) loaded on the roof than what was originally submitted (Owens Corning) before Building Final can be approved. 3/16/2023 - PREVIOUS INSPECTION NOTES 3/15/23: Previously listed deficiency is not resolved. Flashing cannot run across the valley because there is no effective way to seal the area from wind blown rain and/or rodents (G2402.9) 3/14/2023 - PREVIOUS INSPECTION NOTES 3/14/23: Please have Porta John moved from the adjacent swale of the adjacent private property to the building site. 1). 5" x 5" flashing at front entry is installed incorrectly. Flashing must run up the length of the vertical wall and be sealed to the wall as required. | |||
| ROOF VALLEY & METAL | 03/16/2023 | Disapproved -FEE REQUIRED | RSIMS |
| Note: 3/15/23: Previously listed deficiency is not resolved. Flashing cannot run across the valley because there is no effictive way to seal the area from wind blown rain and/or rodents (G2402.9) 3/14/2023 - PREVIOUS INSPECTION NOTES 3/14/23: Please have Porta John moved from the adjacent swale of the adjacent private property to the building site. 1). 5" x 5" flashing at front entry is installed incorrectly. Flashing must run up the length of the vertical wall and be sealed to the wall as required. | |||
| ROOF VALLEY & METAL | 03/14/2023 | Disapproved - NO FEE | RSIMS |
| Note: 3/14/23: Please have Porta John moved from the adjacent swale of the adjacent private property to the building site. 1). 5" x 5" flashing at front entry is installed incorrectly. Flashing must run up the length of the vertical wall and be sealed to the wall as required. | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 03/09/2023 | APPROVED | BTAYLOR |
| Note: 1/24/2023 - PREVIOUS INSPECTION NOTES Prints call for truss system. Roof has been conventional framed. Please submit a revision to the building department showing as built. Include wood sizes, beam consturction, ceiling construction, anchors any bearing walls etc. | |||
| WALL SHEATHING | 01/24/2023 | APPROVED | JWALKER |
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 01/24/2023 | Disapproved - NO FEE | JWALKER |
| Note: Prints call for truss system. Roof has been conventional framed. Please submit a revision to the building department showing as built. Include wood sizes, beam consturction, ceiling construction, anchors any bearing walls etc. | |||
| TIE BEAM / LINTEL | 10/21/2022 | APPROVED | RSIMS |
| FOUND SURVEY APPROVED (OFFICE) | 10/13/2022 | APPROVED | TBAKER |
| MONOLITHIC SLAB | 09/20/2022 | APPROVED | TSTAUFFACHER |
| PLUMBING 1ST ROUGH UNDERGROUND | 08/05/2022 | APPROVED | MGIBSON |
| WATER METER INSTALLATION REQUEST | 07/13/2022 | APPROVED | CSTONE |
Review History
| Department | Status | Date In | Date Out |
| BLD | COMPLETE | 03/21/2023 | 03/23/2023 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 03/03/2023 | 03/07/2023 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| BLD | HOLD | 02/22/2023 | 02/23/2023 |
| Note: Held By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM All comments below per the 2020 Florida Building Code REVIEW COMMENTS: 1. Proposed 2 x 12 rafters are over spanned. Max span for 2 x 12 #2 SYP is 19 feet 6 inches, per the WFCM. | |||
| ENGIN1 | COMPLETE | 10/13/2022 | 10/13/2022 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 10/13/2022 | 10/13/2022 |
| Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM | |||
| ELEC | COMPLETE | 06/08/2022 | 06/09/2022 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| ELEC | HOLD | 05/13/2022 | 05/13/2022 |
| Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM Pool equipment still on electric page | |||
| MECH | COMPLETE | 05/13/2022 | 05/13/2022 |
| Note: Released By: CHRIS PISCITELLI - (386)986-3782 - CPISCITELLI@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 05/13/2022 | 05/13/2022 |
| Note: Released By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM | |||
| SWALE | COMPLETE | 04/19/2022 | 06/16/2022 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| BLD | HOLD | 04/18/2022 | 04/25/2022 |
| Note: Held By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM All comments below per the 2020 Florida Building Code REVIEW COMMENTS: 1. Following comments are for the Product Approvals Per F.S. 471.025 and F.A.C. 61 G15-23.005. a. FL 12590.1 – Not Current Swing Door b. FL 23752.1 – Not Current Soffit Material c. Wood Connectors, Wood Anchors and Truss Plate. Not Provided. | |||
| CUSVC | COMPLETE | 04/18/2022 | 04/21/2022 |
| Note: Released By: ALYSSA ROSCOE - - | |||
| ELEC | HOLD | 04/18/2022 | 04/19/2022 |
| Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM Electric load calcs need to show pool equipment. | |||
| ENGIN1 | COMPLETE | 04/18/2022 | 04/19/2022 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| LOCATE | COMPLETE | 04/18/2022 | 04/25/2022 |
| Note: Released By: CANDACE STONE - - CSTONE@PALMCOASTGOV.COM | |||
| MECH | HOLD | 04/18/2022 | 04/19/2022 |
| Note: Held By: CHRIS PISCITELLI - (386)986-3782 - CPISCITELLI@PALMCOASTGOV.COM Plans show R38 insulation in attic with vented soffit. Energy Calcs say R20 with unvented soffit. Revise to match | |||
| SW1 | COMPLETE | 04/18/2022 | 04/25/2022 |
| Note: Released By: PARREN FLANAGAN - - PFLANAGAN@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 04/18/2022 | 04/19/2022 |
| Note: Released By: CINDY CHIRI-GONCALVES - - CGONCALVES@PALMCOASTGOV.COM |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| CONTRACTOR CHANGE | ¤40.00 | 09/18/2023 |
| SW ENG REINSPECTION 20 | ¤20.00 | 09/18/2023 |
| SW ENG REINSPECTION 30 | ¤30.00 | 09/18/2023 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 09/18/2023 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 09/18/2023 |
| CONNECTION FEES | ¤1,077.88 | 07/06/2022 |
| WATER- TURN ON | ¤25.00 | 07/06/2022 |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | 07/06/2022 |
| INSPECTION - RESIDENTIAL | ¤756.25 | 07/06/2022 |
| PLAN REVIEW - RESIDENTIAL | ¤214.50 | 07/06/2022 |
| SW ENG - REVIEW 20 | ¤20.00 | 07/06/2022 |
| SW ENG RES REVIEW 200 | ¤200.00 | 07/06/2022 |
| 3% TRANS IMPACT FEE CREDIT | (¤52.92) | 07/06/2022 |
| SEWER CREDIT | (¤1,466.00) | 07/06/2022 |
| SEWER INSPECTION | ¤25.00 | 07/06/2022 |
| SEWER CAPITAL FACILITY | ¤4,939.76 | 07/06/2022 |
| WATER CAPITAL FACILITY FEE | ¤3,626.50 | 07/06/2022 |
| SITE PLAN 30 | ¤30.00 | 07/06/2022 |
| 3% FIRE IMPACT FEE CREDIT | (¤11.66) | 07/06/2022 |
| IMPACT FEE FIRE | ¤388.65 | 07/06/2022 |
| IMPACT FEE PARKS | ¤1,455.13 | 07/06/2022 |
| IMPACT FEE SCHOOL | ¤3,600.00 | 07/06/2022 |
| IMPACT FEE TRANSPORTATION | ¤1,764.00 | 07/06/2022 |
| WATER -IRRIGATION INSPECTION | ¤25.00 | 07/06/2022 |
| 3% PARKS IMPACT FEE CREDIT | (¤43.65) | 07/06/2022 |
| SURCHARGE FS 533.721 | ¤8.37 | 07/06/2022 |
| SURCHARGE - FS 468.631 | ¤12.56 | 07/06/2022 |
| SW ENG - FOUNDATION SURVEY | ¤20.00 | 07/06/2022 |
| SW ENG INSPECTION 80 | ¤80.00 | 07/06/2022 |
| SW ENG PRE APRON | ¤30.00 | 07/06/2022 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤16,924.37 |