I want to search for...
Permit #2022031394
Permit Details
Status: COED
| Parcel Id: 07-11-31-7003-00010-0070 |
| CONDITIONED SPACE: 2668 sqft |
| GARAGE: 746 sqft |
| OPENED PORCH (WITH ROOF) : 843 sqft |
| OPENED PORCH (WITH ROOF) : 69 sqft |
| Total Square Footage: 4326 sqft |
| Block: 00010 |
| Subdivision: 2190 - SECTION 3-COUNTRY CLUB COVE |
| Job Phone: 912-258-2201 |
| Location Address: 13 CHESNEY CT |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 04/22/2022 |
| NOC: RECORDED |
| Applicant name: JAMES FUCETOLA III |
| Owner: PALM COAST COMMUNITIES LLC |
|
Address PO BOX 22547 ST SIMONS ISLAND, GA 31522 |
| Lot: 0070 |
| Contracted Stated Job Value: ¤260,000.00 |
| Job Description: Single Family Residence |
| Type: CN |
Contractor
PALM COAST COMMUNITIES LLC
| Status | Location Address | State License Number | Phone |
| INACTIVE |
PO BOX 22547 PALM COAST, FL 32164 |
CBC1262878 (Exp: 08/31/2026) | 321-501-4617 |
Sub Contractors
OLEG BELINSKIY
| Status | Location Address | State License Number | Phone |
| ACTIVE |
19 PINE CIRCLE DRIVE19 PALM COAST, FL 32167 |
CCC1325974 (Exp: 08/31/2026) | 386-263-7906 |
GARY LLOYD SHEFFIELD
| Status | Location Address | State License Number | Phone |
| ACTIVE |
48 EAGLE LAKES DRIVE FLAGLER BEACH, FL 32136 |
CAC048127 (Exp: 08/31/2026) | 386-597-3280 |
JEFFREY TROY SABAKA
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
2191 DEERWOOD ACRES DR ST AUGUSTINE, FL 32084 |
CFC1427439 (Exp: 08/31/2026) | 904-838-2218 | 904-819-0965 |
WILLIAM FRANK DUDLEY JR.
| Status | Location Address | State License Number | Phone |
| ACTIVE |
P.O. BOX 978 Bunnell, FL 32110 |
EC0003177 (Exp: 08/31/2026) | (386)437-3068 |
Inspection History
| Type | Request Date | Result | Inspector |
| ROW - STORMWATER FINAL | 01/04/2023 | APPROVED | GBERTOLA |
| Note: AT THE TIME OF THE INSPECTION EVERYTHING LOOK GOOD | |||
| BLD - BUILDING FINAL | 01/03/2023 | FINAL APPROVED | AGAETANO |
| Note: 12/28/2022 - PREVIOUS INSPECTION NOTES 12-28-2022 Energy calculations do not match. Please submit a revision to the building department and have approved calcs on site for inspection. | |||
| BLD - BUILDING FINAL | 12/28/2022 | Disapproved - NO FEE | AGAETANO |
| Note: 12-28-2022 Energy calculations do not match. Please submit a revision to the building department and have approved calcs on site for inspection. | |||
| U -UTILITY RESIDENTIAL FINAL | 12/28/2022 | FINAL APPROVED | DHANEY |
| ROW FIELD SURVEY /GRADING CERTIFICATION | 12/27/2022 | APPROVED | PFLANAGAN |
| ROW - FINAL APRON (AFTER POUR) | 12/27/2022 | APPROVED | PFLANAGAN |
| FINAL SURVEY (OFFICE USE ONLY) | 12/27/2022 | APPROVED | GBERTOLA |
| U-CROSS CONNECTION | 12/22/2022 | APPROVED - AS NOTED | JHARDING |
| Note: No cross connections. | |||
| ROW- PRE-APRON (PRE-POUR) | 11/28/2022 | APPROVED | EMADISON |
| Note: ** 11/28/22 MAKE SURE THERE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL ** READY TO POUR IN THE EVENT OF RAIN RECHECK ELEVATIONS AND COMPACTION | |||
| ELECTRIC - EARLY POWER | 11/15/2022 | APPROVED | AGAETANO |
| Note: 11-15-2022 FPL Notified at 3:01 pm | |||
| U - SEWER TIE IN | 11/01/2022 | APPROVED | MGIBSON |
| INSULATION | 09/26/2022 | APPROVED | AGAETANO |
| ALL ROUGH | 09/16/2022 | APPROVED | AGAETANO |
| Note: 9/15/2022 - PREVIOUS INSPECTION NOTES | |||
| ALL ROUGH | 09/15/2022 | CANCELLED BY APPLICANT | AGAETANO |
| LATH/BRICK/ WATER BARRIER | 09/06/2022 | APPROVED - AS NOTED | AGAETANO |
| Note: 09-06-2022 Contractor completing the last few pieces of window stops. | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 08/17/2022 | APPROVED | DCUSHING |
| Note: THIS IS A REINSPECTION THIS IS A REINSPECTION THIS IS A REINSPECTION 1. missing down rods per interior bearing wall (see detail), 2. missing nails in HTUI26 highlighted on engineering plans 3. missing nail in piggy back gang nail plates (check all inspection stopped (need details for truss agtachements with screws or other attachments 8-11-22 1. Strap missing on double truss. Only has one holding it down. 2. Strap not nailed off on truss I12. 3. Engineering not complete. 4. Spruce used for engineering. Inspection stopped | |||
| ROOF VALLEY & METAL | 08/12/2022 | APPROVED | LMILLER |
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 08/11/2022 | Disapproved - NO FEE | BTAYLOR |
| Note: THIS IS A REINSPECTION THIS IS A REINSPECTION 1. missing down rods per interior bearing wall (see detail), 2. missing nails in HTUI26 highlighted on engineering plans 3. missing nail in piggy back gang nail plates (check all inspection stopped (need details for truss agtachements with screws or other attachments 8-11-22 1. Strap missing on double truss. Only has one holding it down. 2. Strap not nailed off on truss I12. 3. Engineering not complete. 4. Spruce used for engineering. Inspection stopped | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 08/09/2022 | CANCELLED BY APPLICANT | LMILLER |
| Note: THIS IS A REINSPECTION 1. missing down rods per interior bearing wall (see detail), 2. missing nails in HTUI26 highlighted on engineering plans 3. missing nail in piggy back gang nail plates (check all inspection stopped (need details for truss agtachements with screws or other attachments | |||
| WINDOW NAILING | 08/09/2022 | APPROVED | LMILLER |
| Note: a note on the roof sheathing, braces, ties, down cells inspection asked for slider track inspection only so that inspection was cancelled and I added an inspection for window nailing for slider track screws. inspection result is approved | |||
| WALL SHEATHING | 08/05/2022 | APPROVED | LMILLER |
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 08/05/2022 | Disapproved -FEE REQUIRED | LMILLER |
| Note: 1. missing down rods per interior bearing wall (see detail), 2. missing nails in HTUI26 highlighted on engineering plans 3. missing nail in piggy back gang nail plates (check all (need details for truss agtachements with screws or other attachments) inspection stopped | |||
| ROOF SHEATHING | 08/05/2022 | APPROVED | LMILLER |
| ELEV CERT-FOUNDATION APPROVAL | 08/04/2022 | APPROVED | JMYERS |
| TIE BEAM / LINTEL | 07/11/2022 | APPROVED | AGAETANO |
| MONOLITHIC SLAB | 06/23/2022 | APPROVED | DCUSHING |
| Note: THIS IS A REINSPECTION THIS IS A REINSPECTION 1. UFER ground not visible. 2. The front left corner of the CMU and footing appears to be sinking. Possible structural issues at thia area. Further observation is needed to proceed with inspection. 06-21-2022 - 1. The front left corner of the CMU and footing appears to be sinking. Provide engineering report to clear any potential concerns of the sinking CMU and footing. 6.23.22 - Letter from EOR on file, repair made | |||
| ELECTRIC TEMP POLE | 06/22/2022 | APPROVED | AGAETANO |
| MONOLITHIC SLAB | 06/21/2022 | Disapproved -FEE REQUIRED | AGAETANO |
| Note: THIS IS A REINSPECTION 1. UFER ground not visible. 2. The front left corner of the CMU and footing appears to be sinking. Possible structural issues at thia area. Further observation is needed to proceed with inspection. 06-21-2022 - 1. The front left corner of the CMU and footing appears to be sinking. Provide engineering report to clear any potential concerns of the sinking CMU and footing. | |||
| MONOLITHIC SLAB | 06/17/2022 | Disapproved - NO FEE | AGAETANO |
| Note: 1. UFER ground not visible. 2. The front left corner of the CMU and footing appears to be sinking. Possible structural issues at thia area. Further observation is needed to proceed with inspection. | |||
| PLUMBING 1ST ROUGH UNDERGROUND | 06/15/2022 | APPROVED | MGIBSON |
| GRAVITY SEWER TEST | 06/15/2022 | APPROVED | MGIBSON |
| FOUND SURVEY APPROVED (OFFICE) | 06/08/2022 | APPROVED | TBAKER |
| STEM WALL FOUNDATION | 05/27/2022 | APPROVED | AGAETANO |
| Note: THIS IS A REINSPECTION THIS IS A REINSPECTION 05-24-2022 1. Please revise garage foundation area and entry area where CMU has been installed. 2. Please provide a full set of approved drawings on site for inspection. | |||
| STEM WALL FOUNDATION | 05/24/2022 | Disapproved - NO FEE | AGAETANO |
| Note: THIS IS A REINSPECTION 05-24-2022 1. Please revise and submit to the Building Department the garage foundation area and entry area where CMU has been installed. 2. Please provide a full set of approved drawings on site for inspection. | |||
| STEM WALL FOUNDATION | 05/23/2022 | CANCELLED BY APPLICANT | AGAETANO |
| STEM WALL FOUNDATION | 05/20/2022 | APPROVED - AS NOTED | AGAETANO |
| Note: Back of garage not complete. Contractor will call in another stem wall inspection for that area. Noted on drawings. | |||
| WATER METER INSTALLATION REQUEST | 05/04/2022 | APPROVED | CSTONE |
| Note: THIS IS A REINSPECTION ADDED ON 5/3/2022 8:34:53 AM THIS IS A REINSPECTION ADDED ON 4/27/2022 3:11:30 PM dirt pile in the way NOT CLEAR DIRT PILE IN THE WAY Email rsydnor@palmcoastgov.com with questions | |||
| FOOTER | 05/02/2022 | APPROVED | AGAETANO |
| WATER METER INSTALLATION REQUEST | 04/29/2022 | Disapproved -FEE REQUIRED | CSTONE |
| Note: THIS IS A REINSPECTION ADDED ON 4/27/2022 3:11:30 PM dirt pile in the way NOT CLEAR DIRT PILE IN THE WAY Email rsydnor@palmcoastgov.com with questions | |||
| WATER METER INSTALLATION REQUEST | 04/26/2022 | Disapproved - NO FEE | CSTONE |
| Note: dirt pile in the way |
Review History
| Department | Status | Date In | Date Out |
| PLFM | COMPLETE | 01/11/2023 | 01/11/2023 |
| Note: Released By: JORDAN MYERS, C.F.M - (386)986-2320 - JMYERS@PALMCOASTGOV.COM The Final elevation certificate has been approved. | |||
| PLFM | HOLD | 01/09/2023 | 01/09/2023 |
| Note: Held By: JORDAN MYERS, C.F.M - (386)986-2320 - JMYERS@PALMCOASTGOV.COM This structure is on a stem-wall foundation, as such A7 needs to be 1B instead of 1A. C2a should be 9.7 as the elevation on the survey is 9.65 and should be rounded up when only using one decimal place. | |||
| MECH | COMPLETE | 12/28/2022 | 12/29/2022 |
| Note: Released By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM | |||
| CUSVC | COMPLETE | 09/09/2022 | 09/09/2022 |
| Note: Released By: HALEIGH HAND - - | |||
| PLFM | COMPLETE | 08/04/2022 | 08/04/2022 |
| Note: Released By: JORDAN MYERS, C.F.M - (386)986-2320 - JMYERS@PALMCOASTGOV.COM The foundation elevation certificate has been approved. Please provide Final prior to receiving CO. | |||
| PLFM | HOLD | 08/03/2022 | 08/03/2022 |
| Note: Held By: JORDAN MYERS, C.F.M - (386)986-2320 - JMYERS@PALMCOASTGOV.COM C1 was changed from Building Under Construction to Construction Drawings. It needs to be Building. | |||
| ENGIN1 | COMPLETE | 08/03/2022 | 08/03/2022 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 08/03/2022 | 08/03/2022 |
| Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM | |||
| PLFM | HOLD | 07/29/2022 | 08/01/2022 |
| Note: Held By: JORDAN MYERS, C.F.M - (386)986-2320 - JMYERS@PALMCOASTGOV.COM Foundation EC is dated same day as Construction EC, this is not possible please revise. Foundation survey is missing flood zone lines, elevation for garage, and location of A/C pad noted in C2e. | |||
| BLD | COMPLETE | 06/23/2022 | 06/24/2022 |
| Note: Released By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 06/08/2022 | 06/08/2022 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 06/08/2022 | 06/08/2022 |
| Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 05/26/2022 | 05/26/2022 |
| Note: Released By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM | |||
| PLFM | COMPLETE | 04/19/2022 | 04/20/2022 |
| Note: Released By: JORDAN MYERS, C.F.M - (386)986-2320 - JMYERS@PALMCOASTGOV.COM The construction elevation certificate has been approved. Please provide foundation and final prior to receiving CO. | |||
| ELEC | COMPLETE | 04/14/2022 | 04/18/2022 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| PLFM | HOLD | 04/14/2022 | 04/14/2022 |
| Note: Held By: JORDAN MYERS, C.F.M - (386)986-2320 - JMYERS@PALMCOASTGOV.COM The following comments are in regards to the Elevation Certificate: B1 still has incorrect information. B9 is still missing a measurement mark on the Base Flood Elevation. | |||
| ELEC | HOLD | 04/07/2022 | 04/07/2022 |
| Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM Outlets in bathrrom need to be GFCI protected. NEC 2017 210.8 | |||
| BLD | COMPLETE | 04/07/2022 | 04/07/2022 |
| Note: Released By: FRED REODICA - (386)986-4734 - FREODICA@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 04/07/2022 | 04/07/2022 |
| Note: Released By: CINDY CHIRI-GONCALVES - - CGONCALVES@PALMCOASTGOV.COM | |||
| PLFM | HOLD | 04/07/2022 | 04/08/2022 |
| Note: Held By: JORDAN MYERS, C.F.M - (386)986-2320 - JMYERS@PALMCOASTGOV.COM The following comments are in regards to the Elevation Certificate: A3 needs more information. A4 needs a use stated. B1 has incorrect information. B9 needs to be stated as 7.0'. Section D there needs to be a signature and date on top of the seal, and the machinery referenced in C2e needs to by noted in the Comments. | |||
| ENGIN1 | COMPLETE | 04/07/2022 | 04/08/2022 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| SW1 | COMPLETE | 04/07/2022 | 04/11/2022 |
| Note: Released By: KALEN RUTH - (386)566-1273 - KRUTH@PALMCOASTGOV.COM | |||
| PLFM | HOLD | 03/28/2022 | 03/28/2022 |
| Note: Held By: JORDAN MYERS, C.F.M - (386)986-2320 - JMYERS@PALMCOASTGOV.COM According to the Site Plan submitted on 3/25/22, the structure falls within the Special Flood Hazard Area. Elevation certificates are required at construction, foundation, and final. | |||
| BLD | HOLD | 03/25/2022 | 03/28/2022 |
| Note: Held By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM All comments below per the 2020 Florida Building Code PLAN REVIEW COMMENTS: 1. Product approval for the roofing shingles noted on the Roofing Worksheet and Product Approval do not match. F.S. 553.842 | |||
| CUSVC | COMPLETE | 03/25/2022 | 03/31/2022 |
| Note: Released By: ALYSSA ROSCOE - - | |||
| ELEC | HOLD | 03/25/2022 | 03/25/2022 |
| Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. Reccesed cans in garage need to be fire rated, submit manufacture specs on cans. FRC 2020 302.5 2. Outlets in laundry room, kitchen,garage,bathrooms need to be GFCI protected. NEC 2017 210.8 3. Need correct outlet spacing in master bedroom. NEC 2017 210.52 4. Outlets in soffit need to be GFCI protected. NEC 2017 210.8 | |||
| ENGIN1 | COMPLETE | 03/25/2022 | 03/25/2022 |
| Note: Released By: JOHN HOWARD - - JHOWARD@PALMCOASTGOV.COM | |||
| LOCATE | COMPLETE | 03/25/2022 | 04/04/2022 |
| Note: Released By: CANDACE STONE - - CSTONE@PALMCOASTGOV.COM | |||
| MECH | COMPLETE | 03/25/2022 | 03/25/2022 |
| Note: Released By: CHRIS PISCITELLI - (386)986-3782 - CPISCITELLI@PALMCOASTGOV.COM | |||
| SW1 | COMPLETE | 03/25/2022 | 04/01/2022 |
| Note: Released By: PARREN FLANAGAN - - PFLANAGAN@PALMCOASTGOV.COM | |||
| ZON | HOLD | 03/25/2022 | 03/28/2022 |
| Note: Held By: CINDY CHIRI-GONCALVES - - CGONCALVES@PALMCOASTGOV.COM Trees: One tree for every 2500 square ft. All calculations are rounded to the nearest whole number. This property requires 5 trees Shrubs: *Six Shrubs shall be planted on each side of the home facing the street. Site plan: please provide the width of walkway to entry of home | |||
| SWALE | COMPLETE | 03/25/2022 | 08/26/2022 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| WATER-METER | ¤467.09 | 09/22/2022 |
| WATER- TURN ON | ¤25.00 | 09/22/2022 |
| PLAN REVIEW - REVISION | ¤32.50 | 09/22/2022 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 09/22/2022 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 09/22/2022 |
| PLAN REVIEW - REVISION | ¤32.50 | 09/22/2022 |
| WATER -IRRIGATION INSPECTION | ¤25.00 | 09/22/2022 |
| REINSPECTION FEE | ¤40.00 | 09/22/2022 |
| PLAN REVIEW - REVISION | (¤32.50) | 09/16/2022 |
| REINSPECTION FEE | ¤40.00 | 09/16/2022 |
| REINSPECTION FEE | (¤40.00) | 09/16/2022 |
| REINSPECTION RESIDENTIAL | (¤40.00) | 09/16/2022 |
| WATER -IRRIGATION INSPECTION | ¤25.00 | 09/16/2022 |
| WATER -IRRIGATION INSPECTION | (¤25.00) | 09/16/2022 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 09/16/2022 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 09/16/2022 |
| REINSPECTION RESIDENTIAL | (¤40.00) | 09/16/2022 |
| PLAN REVIEW - REVISION | ¤32.50 | 09/16/2022 |
| PLAN REVIEW - REVISION | ¤32.50 | 09/16/2022 |
| PLAN REVIEW - REVISION | (¤32.50) | 09/16/2022 |
| WATER- TURN ON | ¤25.00 | 09/16/2022 |
| WATER- TURN ON | (¤25.00) | 09/16/2022 |
| WATER-METER | ¤467.09 | 09/16/2022 |
| WATER-METER | (¤467.09) | 09/16/2022 |
| WATER- TURN ON | ¤25.00 | 04/22/2022 |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | 04/22/2022 |
| INSPECTION - RESIDENTIAL | ¤1,001.00 | 04/22/2022 |
| PLAN REVIEW - RESIDENTIAL | ¤283.92 | 04/22/2022 |
| 3% PARKS IMPACT FEE CREDIT | (¤43.65) | 04/22/2022 |
| CONNECTION FEES | ¤1,077.88 | 04/22/2022 |
| 3% FIRE IMPACT FEE CREDIT | (¤11.66) | 04/22/2022 |
| IMPACT FEE FIRE | ¤388.65 | 04/22/2022 |
| IMPACT FEE PARKS | ¤1,455.13 | 04/22/2022 |
| IMPACT FEE SCHOOL | ¤3,600.00 | 04/22/2022 |
| IMPACT FEE TRANSPORTATION | ¤1,764.00 | 04/22/2022 |
| WATER -IRRIGATION INSPECTION | ¤25.00 | 04/22/2022 |
| SURCHARGE FS 533.721 | ¤13.79 | 04/22/2022 |
| SURCHARGE - FS 468.631 | ¤20.69 | 04/22/2022 |
| SW ENG - FOUNDATION SURVEY | ¤20.00 | 04/22/2022 |
| SW ENG INSPECTION 80 | ¤80.00 | 04/22/2022 |
| SW ENG PRE APRON | ¤30.00 | 04/22/2022 |
| SW ENG - REVIEW 20 | ¤20.00 | 04/22/2022 |
| SW ENG RES REVIEW 200 | ¤200.00 | 04/22/2022 |
| 3% TRANS IMPACT FEE CREDIT | (¤52.92) | 04/22/2022 |
| SEWER INSPECTION | ¤25.00 | 04/22/2022 |
| SEWER CAPITAL FACILITY | ¤4,939.76 | 04/22/2022 |
| WATER CAPITAL FACILITY FEE | ¤3,626.50 | 04/22/2022 |
| SITE PLAN 30 | ¤30.00 | 04/22/2022 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤19,250.18 |