I want to search for...

Permit #2022031626

Permit Details

Status: FINAL

Parcel Id: 07-11-31-7003-00080-0210
CONDITIONED SPACE: 1050 sqft
PATIO/DECK (NO ROOF) : 672 sqft
Total Square Footage: 1722 sqft
Block: 00080
Subdivision: 2190 - SECTION 3-COUNTRY CLUB COVE
Job Phone: (386)547-0991
Location Address: 15 CLOVERDALE CT S
Type: BA - BUILDING ADDITION
Issue Date: 06/27/2022
NOC: RECORDED
Applicant name: STEVE HARKINS
Owner: FORTE SHARON MARIE & ALAN CHRISTOPHER FORTE W&H

Address

15 CLOVERDALE COURT S

PALM COAST, FL 32137

Lot: 0210
Contracted Stated Job Value: ¤151,000.00
Job Description: ADDITION AND 42X16 CONCRETE PATIO
Type: CN

Contractor

HARKINS CUSTOM CONSTRUCTION INC.
Status Location Address State License Number Phone
ACTIVE

665 STREET TRAIL

BUNNELL, FL 32110

CBC1253997 (Exp: 08/31/2026) 386-449-9413

Sub Contractors

GREGORY A HAGEMAN
Status Location Address State License Number Phone
ACTIVE

545 Parque Drive

Ormond Beach, FL 32174

CCC021394 (Exp: 08/31/2026) (386) 672-2821
ROBERT JOHN TROWBRIDGE
Status Location Address State License Number Phone
INACTIVE

3801 Long Grove Lane

Port Orange, 32119

CAC057234 (Exp: 08/31/2024) (386) 767-9735
MARK E SMITH
Status Location Address State License Number Phone Fax
ACTIVE

P. O. Box 351482

PALM COAST, FL 32164

EC0002128 (Exp: 08/31/2026) (386) 437-8496 386-586-3612
ROBERT BERTOLINI JR
Status Location Address State License Number Phone
ACTIVE

15 WEBWOOD PLACE

PALM COAST, FL 32164

RF11067617 (Exp: 08/31/2027) 386-627-0560

Inspection History

Type Request Date Result Inspector
U -UTILITY RESIDENTIAL FINAL 01/23/2023 FINAL APPROVED DHANEY
BLD - BUILDING FINAL 01/19/2023 Disapproved - NO FEE AGAETANO
Note: 01-19-2023 Bedroom and living room smoke alarms need to be interconnected.
BLD - BUILDING FINAL 01/19/2023 FINAL APPROVED AGAETANO
ROW- FINAL SURVEY/GRADING CERTIFICATION 01/13/2023 APPROVED GBERTOLA
Note: 1/12/23= Correction were made 1/12/2023 - PREVIOUS INSPECTION NOTES ** 01/12/23 NEED TO READ PREVIOUS INSPECTOR NOTES AND SUBMIT A TOPOGRAPHIC SURVEY NOT A BOUNDARY SURVEY 1/4/2023 - PREVIOUS INSPECTION NOTES THIS IS A BOUNDARY SURVEY, WE NEED A TOPOGRAPHIC SURVEYS
ROW FIELD SURVEY /GRADING CERTIFICATION 01/13/2023 APPROVED EMADISON
ROW - FINAL INSPECTION 01/13/2023 FINAL APPROVED EMADISON
ROW FIELD SURVEY /GRADING CERTIFICATION 01/12/2023 CANCELLED BY INSPECTOR GBERTOLA
ROW- FINAL SURVEY/GRADING CERTIFICATION 01/12/2023 Disapproved - NO FEE EMADISON
Note: ** 01/12/23 NEED TO READ PREVIOUS INSPECTOR NOTES AND SUBMIT A TOPOGRAPHIC SURVEY NOT A BOUNDARY SURVEY 1/4/2023 - PREVIOUS INSPECTION NOTES THIS IS A BOUNDARY SURVEY, WE NEED A TOPOGRAPHIC SURVEYS
ROW- FINAL SURVEY/GRADING CERTIFICATION 01/04/2023 Disapproved - NO FEE GBERTOLA
Note: THIS IS A BOUNDARY SURVEY, WE NEED A TOPOGRAPHIC SURVEYS
INSULATION 11/15/2022 APPROVED DCUSHING
Note: 11/14/2022 - PREVIOUS INSPECTION NOTES Inspector Notes from Inspection 2420 10/26/2022 - PREVIOUS INSPECTION NOTES Inspector Notes from Inspection 2460 11-14-2022 Multiple batts in ceiling and walls are not fastened. Multiple gaps in ceiling. 9/26/2022 - PREVIOUS INSPECTION NOTES Inspector Notes from Inspection 2250 Inspector Notes from Inspection 2280 THIS IS A REINSPECTION The stem wall was already inspected. 09-08-2022 Homeowner built a birm at on the slab to reroute water. He will remove it prior to the slab pour. 09-26-2022 1. Valley rafter shoe plate not installed as per drawings. Please submit a revision to the building department or install as per drawings. 2. 1/F interior stud bearing at existing wall calls for dbl top plate. Pleae submit a revision for the blocking and straps used. 3. Provide details of valley rafter and scabbing. 4. Missed T01 & T04. 5. H25 missed at utility room sleepers. Roof sheathing OK and approved. Inspection stopped. Contractor not ready. 10-25-2022 1. Please submit revision Sheet 1 of 2 to the building department for review. 2. Please submit Sheet 1 of 2 1F Typical Block Wall Section. Top plate not installed as per plans. Each truss has one PT. block under each truss. 10-26-2022 1. Please install larger nail plates on the vent in bathroom. 2. Mechanical drawings not on site. 3. Detail 1/3 Typical block wall section not installed as per plan on existing CMU to new trusses. Straps used. Please revise and reflect on drawings. 4. Roof vent not wired and not shown on drawings. Please submit to the bulding department. 5. Please revise and submit to the building department all electrical including the two new outlets added in the existing bedroom. 11-07-2022 Exterior outets grounds need to be connected. All grounds need to be connected – NEC 110.14A. Check at insulation inspection.
INSULATION 11/14/2022 Disapproved - NO FEE AGAETANO
Note: Inspector Notes from Inspection 2420 10/26/2022 - PREVIOUS INSPECTION NOTES Inspector Notes from Inspection 2460 11-14-2022 Multiple batts in ceiling and walls are not fastened. Multiple gaps in ceiling. 9/26/2022 - PREVIOUS INSPECTION NOTES Inspector Notes from Inspection 2250 Inspector Notes from Inspection 2280 THIS IS A REINSPECTION The stem wall was already inspected. 09-08-2022 Homeowner built a birm at on the slab to reroute water. He will remove it prior to the slab pour. 09-26-2022 1. Valley rafter shoe plate not installed as per drawings. Please submit a revision to the building department or install as per drawings. 2. 1/F interior stud bearing at existing wall calls for dbl top plate. Pleae submit a revision for the blocking and straps used. 3. Provide details of valley rafter and scabbing. 4. Missed T01 & T04. 5. H25 missed at utility room sleepers. Roof sheathing OK and approved. Inspection stopped. Contractor not ready. 10-25-2022 1. Please submit revision Sheet 1 of 2 to the building department for review. 2. Please submit Sheet 1 of 2 1F Typical Block Wall Section. Top plate not installed as per plans. Each truss has one PT. block under each truss. 10-26-2022 1. Please install larger nail plates on the vent in bathroom. 2. Mechanical drawings not on site. 3. Detail 1/3 Typical block wall section not installed as per plan on existing CMU to new trusses. Straps used. Please revise and reflect on drawings. 4. Roof vent not wired and not shown on drawings. Please submit to the bulding department. 5. Please revise and submit to the building department all electrical including the two new outlets added in the existing bedroom. 11-07-2022 Exterior outets grounds need to be connected. All grounds need to be connected – NEC 110.14A. Check at insulation inspection.
ALL ROUGH 11/07/2022 APPROVED - AS NOTED AGAETANO
Note: 10/26/2022 - PREVIOUS INSPECTION NOTES Inspector Notes from Inspection 2460 9/26/2022 - PREVIOUS INSPECTION NOTES Inspector Notes from Inspection 2250 Inspector Notes from Inspection 2280 THIS IS A REINSPECTION The stem wall was already inspected. 09-08-2022 Homeowner built a birm at on the slab to reroute water. He will remove it prior to the slab pour. 09-26-2022 1. Valley rafter shoe plate not installed as per drawings. Please submit a revision to the building department or install as per drawings. 2. 1/F interior stud bearing at existing wall calls for dbl top plate. Pleae submit a revision for the blocking and straps used. 3. Provide details of valley rafter and scabbing. 4. Missed T01 & T04. 5. H25 missed at utility room sleepers. Roof sheathing OK and approved. Inspection stopped. Contractor not ready. 10-25-2022 1. Please submit revision Sheet 1 of 2 to the building department for review. 2. Please submit Sheet 1 of 2 1F Typical Block Wall Section. Top plate not installed as per plans. Each truss has one PT. block under each truss. 10-26-2022 1. Please install larger nail plates on the vent in bathroom. 2. Mechanical drawings not on site. 3. Detail 1/3 Typical block wall section not installed as per plan on existing CMU to new trusses. Straps used. Please revise and reflect on drawings. 4. Roof vent not wired and not shown on drawings. Please submit to the bulding department. 5. Please revise and submit to the building department all electrical including the two new outlets added in the existing bedroom. 11-07-2022 Exterior outets grounds need to be connected. All grounds need to be connected – NEC 110.14A. Check at insulation inspection.
ALL ROUGH 10/26/2022 Disapproved - NO FEE AGAETANO
Note: Inspector Notes from Inspection 2460 9/26/2022 - PREVIOUS INSPECTION NOTES Inspector Notes from Inspection 2250 Inspector Notes from Inspection 2280 THIS IS A REINSPECTION The stem wall was already inspected. 09-08-2022 Homeowner built a birm at on the slab to reroute water. He will remove it prior to the slab pour. 09-26-2022 1. Valley rafter shoe plate not installed as per drawings. Please submit a revision to the building department or install as per drawings. 2. 1/F interior stud bearing at existing wall calls for dbl top plate. Pleae submit a revision for the blocking and straps used. 3. Provide details of valley rafter and scabbing. 4. Missed T01 & T04. 5. H25 missed at utility room sleepers. Roof sheathing OK and approved. Inspection stopped. Contractor not ready. 10-25-2022 1. Please submit revision Sheet 1 of 2 to the building department for review. 2. Please submit Sheet 1 of 2 1F Typical Block Wall Section. Top plate not installed as per plans. Each truss has one PT. block under each truss. 10-26-2022 1. Please install larger nail plates on the vent in bathroom. 2. Mechanical drawings not on site. 3. Detail 1/3 Typical block wall section not installed as per plan on existing CMU to new trusses. Straps used. Please revise and reflect on drawings. 4. Roof vent not wired and not shown on drawings. Please submit to the bulding department. 5. Please revise and submit to the building department all electrical including the two new outlets added in the existing bedroom.
ROOF SHEATHING / BRACES/TIES/DOWN CELL 10/25/2022 APPROVED - AS NOTED AGAETANO
Note: 9/26/2022 - PREVIOUS INSPECTION NOTES Inspector Notes from Inspection 2250 Inspector Notes from Inspection 2280 THIS IS A REINSPECTION The stem wall was already inspected. 09-08-2022 Homeowner built a birm at on the slab to reroute water. He will remove it prior to the slab pour. 09-26-2022 1. Valley rafter shoe plate not installed as per drawings. Please submit a revision to the building department or install as per drawings. 2. 1/F interior stud bearing at existing wall calls for dbl top plate. Pleae submit a revision for the blocking and straps used. 3. Provide details of valley rafter and scabbing. 4. Missed T01 & T04. 5. H25 missed at utility room sleepers. Roof sheathing OK and approved. Inspection stopped. Contractor not ready. 10-25-2022 1. Please submit revision Sheet 1 of 2 to the building department for review. 2. Please submit Sheet 1 of 2 1F Typical Block Wall Section. Top plate not installed as per plans. Each truss has one PT. block under each truss.
ROOF VALLEY & METAL 10/11/2022 APPROVED AGAETANO
ROOF SHEATHING / BRACES/TIES/DOWN CELL 09/26/2022 Disapproved - NO FEE AGAETANO
Note: Inspector Notes from Inspection 2250 Inspector Notes from Inspection 2280 THIS IS A REINSPECTION The stem wall was already inspected. 09-08-2022 Homeowner built a birm at on the slab to reroute water. He will remove it prior to the slab pour. 09-26-2022 1. Valley rafter shoe plate not installed as per drawings. Please submit a revision to the building department or install as per drawings. 2. 1/F interior stud bearing at existing wall calls for dbl top plate. Pleae submit a revision for the blocking and straps used. 3. Provide details of valley rafter and scabbing. 4. Missed T01 & T04. 5. H25 missed at utility room sleepers. Roof sheathing OK and approved. Inspection stopped. Contractor not ready.
MONOLITHIC SLAB 09/08/2022 APPROVED - AS NOTED AGAETANO
Note: Inspector Notes from Inspection 2280 THIS IS A REINSPECTION The stem wall was already inspected. 09-08-2022 Homeowner built a birm at on the slab to reroute water. He will remove it prior to the slab pour.
STEM WALL FOUNDATION 09/07/2022 Disapproved -FEE REQUIRED AGAETANO
Note: 09-07-2022 Most of the stem wall has been filled with concrete. Please submit engineering to the building department stating that the work was completed properly.
STEM WALL FOUNDATION 09/07/2022 APPROVED - AS NOTED AGAETANO
Note: THIS IS A REINSPECTION The stem wall was already inspected.
STEM WALL FOUNDATION 08/23/2022 APPROVED AGAETANO
Note: THIS IS A REINSPECTION Please provided a large readable Approved set of drawings for revision. NEED THE APPROVED DOCUMENTS ON SITE FOR INSPECTION 107.3,1.
STEM WALL FOUNDATION 08/22/2022 Disapproved - NO FEE AGAETANO
Note: Please provided a large readable Approved set of drawings for revision. NEED THE APPROVED DOCUMENTS ON SITE FOR INSPECTION 107.3,1.
STEM WALL FOUNDATION 08/09/2022 APPROVED LMILLER
DOWN CELL 08/05/2022 APPROVED LMILLER
GRAVITY SEWER TEST 08/02/2022 APPROVED MGIBSON
U - SEWER TIE IN 08/02/2022 APPROVED MGIBSON
Note: THIS IS A REINSPECTION WRONG INSPECTION CALLED, NEEDED GRAVITY SEWER, U-SEWER IS WHEN TAP IS MADE INTO EXISTING SEWER
U - SEWER TIE IN 08/01/2022 Disapproved - NO FEE MGIBSON
Note: WRONG INSPECTION CALLED, NEEDED GRAVITY SEWER, U-SEWER IS WHEN TAP IS MADE INTO EXISTING SEWER,, GRAVITY SEWER APPROVED
MONOLITHIC SLAB 07/08/2022 APPROVED AGAETANO
Note: THIS IS A REINSPECTION Compaction test not posted.
MONOLITHIC SLAB 07/07/2022 Disapproved - NO FEE AGAETANO
Note: Compaction test not posted.
PLUMBING 1ST ROUGH UNDERGROUND 07/06/2022 APPROVED MGIBSON
Note: THIS IS A REINSPECTION THIS IS A REINSPECTION W/C FITTING IS A HEEL OUTLET 90 DESIGNED FOR VENTING NOT DRAINAGE, FITTING STILL IN PLACE AND HAS TO BE REMOVED TO PASS FIRST ROUGH PLUMBING INSPECTION, FITTING IS DESIGNED FOR VERTICAL TO HORIZONIAL ''ONLY'' AS VENT, AND DRY VENT DOESN'T MEET CRITERIA FOR DRY VENT APPLICATION. CUT HEEL OUT-LET TEE COMPLETELY AND USE A DIFFERENT METHOD OF W/C CONNECTION
PLUMBING 1ST ROUGH UNDERGROUND 07/05/2022 Disapproved - NO FEE MGIBSON
Note: THIS IS A REINSPECTION W/C FITTING IS A HEEL OUTLET 90 DESIGNED FOR VENTING NOT DRAINAGE, FITTING STILL IN PLACE AND HAS TO BE REMOVED TO PASS FIRST ROUGH PLUMBING INSPECTION, FITTING IS DESIGNED FOR VERTICAL TO HORIZONIAL ''ONLY'' AS VENT, AND DRY VENT DOESN'T MEET CRITERIA FOR DRY VENT APPLICATION. CUT HEEL OUT-LET TEE COMPLETELY AND USE A DIFFERENT METHOD OF W/C CONNECTION
PLUMBING 1ST ROUGH UNDERGROUND 07/01/2022 Disapproved -FEE REQUIRED MGIBSON
Note: W/C FITTING IS A HEEL OUTLET 90 DESIGNED FOR VENTING NOT DRAINAGE

Review History

Department Status Date In Date Out
MECH COMPLETE 11/04/2022 11/04/2022
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
MECH HOLD 11/03/2022 11/04/2022
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
ELEC COMPLETE 11/03/2022 11/04/2022
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
BLD COMPLETE 10/31/2022 10/31/2022
Note: Released By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM
MECH HOLD 10/31/2022 10/31/2022
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Unable to draw on engineered drawings. Provide layout without engineered seal
BLD COMPLETE 10/25/2022 10/26/2022
Note: Released By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM
ELEC COMPLETE 10/25/2022 10/27/2022
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
BLD COMPLETE 10/19/2022 10/24/2022
Note: Released By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM
BLD COMPLETE 10/03/2022 10/03/2022
Note: Released By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM
BLD COMPLETE 08/01/2022 08/02/2022
Note: Released By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM
BLD COMPLETE 07/20/2022 08/01/2022
Note: Released By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM
BLD COMPLETE 06/14/2022 06/15/2022
Note: Released By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM
ZON COMPLETE 06/14/2022 06/15/2022
Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM
ENGIN1 COMPLETE 06/14/2022 06/15/2022
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
SW1 COMPLETE 06/14/2022 06/21/2022
Note: Released By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM
BLD HOLD 06/07/2022 06/07/2022
Note: Held By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM All comments below per the 2020 Florida Building Code REVIEW COMMENTS: Repeat Comment 1. Typical Detail 1/F on Sheet calls-out 2 x 6 rafters. Truss drawings where submitted for the same roof. A revise plans to reflect the correct roof framing method used. Provide which is to be installed. FBC [A] 107.3 2. Provide a Roof Framing Plan. The Roofing Plan was removed from the drawings. FBC [A] 107.3.
ZON HOLD 06/07/2022 06/07/2022
Note: Held By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM You submitted two site plans. They do not match. One doesn't show setbacks and the storage area. The other doesn't have all the dimensions. Please submit one site plan with all this information for approval. It must match plans submitted and have dimensions and setbacks of addition and concrete patio.
PLFM COMPLETE 06/07/2022 06/07/2022
Note: Released By: JORDAN MYERS, C.F.M - (386)986-2320 - JMYERS@PALMCOASTGOV.COM According to the Revised Site Plan submitted on 6/6/22, the addition does not fall within the SFHA. No elevation certificates are required.
ENGIN1 COMPLETE 06/07/2022 06/07/2022
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
SW1 COMPLETE 06/07/2022 06/14/2022
Note: Released By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM
BLD HOLD 05/20/2022 05/23/2022
Note: Held By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM All comments below per the 2020 Florida Building Code – Residential REVIEW COMMENTS: Repeat Comment 1. Roof Framing Plan calls-out 2 x 6 rafters. Truss drawings where submitted for the same roof. A revise plans to reflect the correct roof framing method used. FBC [A] 107.3
ELEC COMPLETE 05/20/2022 05/23/2022
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
ZON HOLD 05/20/2022 05/23/2022
Note: Held By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM Site plan/survey must show the dimensions of addition and the uncovered patio addition with the setback from that concrete slab to rear property line
PLFM HOLD 05/20/2022 05/23/2022
Note: Held By: JORDAN MYERS, C.F.M - (386)986-2320 - JMYERS@PALMCOASTGOV.COM Please provide updated site plan that shows the flood zone line on the property (3rd request). Staff provided Long Surveying, Inc. with the correct Elevation Certificate form to complete.
ELEC HOLD 05/17/2022 05/17/2022
Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM Submit new electrical plan
ZON HOLD 05/17/2022 05/17/2022
Note: Held By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM REPEAT COMMENT: Please provide side and rear setbacks from the proposed addition to property lines on site plan for review Windows and doors facing canal must have banding. Plans must show this
PLFM HOLD 05/17/2022 05/17/2022
Note: Held By: JORDAN MYERS, C.F.M - (386)986-2320 - JMYERS@PALMCOASTGOV.COM Please provide updates site plan that shows the flood zone line on the property. What was submitted was not a complete elevation certificate, please submit a complete elevation certificate on the correct form.
BLD HOLD 05/17/2022 05/17/2022
Note: Held By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM All comments below per the 2020 Florida Building Code – Residential REVIEW COMMENTS: 1. Roof Framing Plan calls-out 2 x 6 rafters. Truss drawings where submitted for the same roof. Provide if raters are to be conventionally framed or truss system is to be installed. FBC [A] 107.3 2. Provide Product Approval for wood connectors and wood anchors. Per F.S. 471.025 and F.A.C. 61 G15-23.005.Roofing Worksheet per City's requirement. Repeat Comment
PLFM HOLD 03/31/2022 03/31/2022
Note: Held By: JORDAN MYERS, C.F.M - (386)986-2320 - JMYERS@PALMCOASTGOV.COM Please provide updates site plan that shows the flood zone line on the property. If this addition is part of the livable structure and falls inside the Special Flood Hazard Area, elevation certificates are required. Construction, foundation, and final.
BLD HOLD 03/30/2022 03/31/2022
Note: Held By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM All comments below per the 2020 Florida Building Code – Residential REVIEW COMMENTS: 1. Proposed 2 x 6 SYP #2 rafters, appear over spanned per the 2018 Wood Frame Construction Manual. A revision is required. FC 107 2. Provide Product Approval for wood connectors and wood anchors. Per F.S. 471.025 and F.A.C. 61 G15-23.005.
ELEC HOLD 03/30/2022 03/30/2022
Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. List electrical sub contractor 2. Need correct outlet spacing in bedroom. NEC 2017 210.52 3. Outlet in bathroom need to be GFCI protected. NEC 2017 210.8 4. Need smoke alarm inside and outside of bedroom. FRC 2020 314.3 & 315.1 5. Need to show size of existing service and prove that it can accomondate the new addition. NEC 2017 220.83
MECH COMPLETE 03/30/2022 03/30/2022
Note: Released By: CHRIS PISCITELLI - (386)986-3782 - CPISCITELLI@PALMCOASTGOV.COM
PLUM CANCEL 03/30/2022 04/01/2022
SW1 COMPLETE 03/30/2022 04/05/2022
Note: Released By: PARREN FLANAGAN - - PFLANAGAN@PALMCOASTGOV.COM
ZON HOLD 03/30/2022 03/31/2022
Note: Held By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM Please provide side and rear setbacks from the proposed addition to property lines on site plan for review Windows and doors facing canal must have banding.

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
PLAN REVIEW - REVISION ¤32.50 01/20/2023
PLAN REVIEW - REVISION ¤32.50 01/20/2023
PLAN REVIEW - REVISION ¤32.50 01/20/2023
PLAN REVIEW - REVISION ¤32.50 01/20/2023
PLAN REVIEW - REVISION ¤32.50 01/20/2023
PLAN REVIEW - REVISION ¤32.50 01/20/2023
REINSPECTION RESIDENTIAL ¤40.00 01/20/2023
CONTRACTOR CHANGE ¤20.00 01/20/2023
SURCHARGE FS 533.721 ¤4.87 06/27/2022
SURCHARGE - FS 468.631 ¤7.31 06/27/2022
SW ENG - INSPECTION 20 ¤20.00 06/27/2022
SW ENG - REVIEW 20 ¤20.00 06/27/2022
SITE PLAN 30 ¤30.00 06/27/2022
ADMINISTRATIVE RESIDENTIAL ¤30.00 06/27/2022
INSPECTION - RESIDENTIAL ¤415.25 06/27/2022
PLAN REVIEW - RESIDENTIAL ¤117.78 06/27/2022
CONTRACTOR CHANGE ¤40.00 06/27/2022
CONTRACTOR CHANGE ¤40.00 06/27/2022
Fees Total Due: ¤0.00 Total Paid: ¤980.21