Permit #2022040259

Permit Details

Status: COED

Parcel Id: 07-11-31-7024-00070-0180
Block: 00070
Subdivision: 2167 - SECTION 24-PINE GROVE
Job Phone: 386-334-4685
Location Address: 24 PRINCESS DOLORES LN
Type: BIA - BUILDING INTERIOR EXTERIOR ALTERATION
Issue Date: 07/14/2022
NOC: RECORDED
Applicant name: SVETLANA ALEXANDRA PEREPECHKINA
Owner: SIPKO IRINA

Address

20 WOODLAWN DR

PALM COAST, FL 32164

Lot: 0180
Contracted Stated Job Value: ¤100,000.00
Job Description: RENOVATION DUE TO FIRE DAMAGE - 2 STORY (COMPLETE DEMO/REPLACE 2ND STORY)
Type: CN

Contractor

WISE CHOICE CUSTOM HOMES, INC.
Status Location Address State License Number Phone
ACTIVE

77 SOUTHLAKE DR

PALM COAST, FL 32137

CGC1515256 (Exp: 08/31/2026) 386-334-4685

Sub Contractors

MAXIM BUDNIK
Status Location Address State License Number Phone
ACTIVE

9788 HALSEY RD

JACKSONVILLE, FL 32246

EC13007415 (Exp: 08/31/2026) 904-509-7306
OLEG BELINSKIY
Status Location Address State License Number Phone
ACTIVE

19 PINE CIRCLE DRIVE19

PALM COAST, FL 32167

CCC1325974 (Exp: 08/31/2026) 386-263-7906
MAXIM BUDNIK
Status Location Address State License Number
ACTIVE

3 WAVECREST PL

PALM COAST, FL 32164

CAC1818445 (Exp: 08/31/2026)
ALEKSANDR A KATKO
Status Location Address State License Number Phone
ACTIVE

130 HARRISON RD

, 0

CFC1431723 (Exp: 08/31/2026) 386-341-3800

Inspection History

Type Request Date Result Inspector
BLD - BUILDING FINAL 06/13/2024 Disapproved - NO FEE RSIMS
Note: 6/13/24: A Virtual inspection will be available IF requested at the time of scheduling the re-inspection. If requesting a Virtual Re-inspection, please schedule the re-inspection for the same day that the deficiencies will be corrected and a FaceTime or Google Meet live virtual inspection can be completed. (Pictures are not approved). 1). AHU in attic is missing the equipment label as required. Model number, etc. cannot be verified. 2). 2nd Floor AHU in attic needs location identified at the breaker for the unit. M1401.1 ________________________________________________________________________________________________________________________ 6/4/2024 - PREVIOUS INSPECTION NOTES 6/4/24: Incomplete Inspection. Too many items to list. 1st floor inspection only complete. 1). Range feed romex is outside of the wall & exposed to damage along with the outlet is not mounted to the wall. Need to check anti-tip bracket for proper anchoring. 2). Kitchen counter outlet - Right side of fridge is reading open ground and will not trip when tested. 3). Right side (Master bathroom) vanity is double trapped with both an 'S' trap feeding into a 'P" trap. 'S' traps are not code acceptable. Also, hot water is on the wrong side. 4). Kitchen sink - Hot water may be on the wrong side. Hot water is only warm. 5). Garage door safety eyes are too high. 6" max off finished floor per UL 325.6 /16CFR part 1211. Note: breaker for bathroom off of kitchen may need to be replaced as there was no power during multiple checks and suddenly turned on by itself. Condensing units both need to be checked. 5/29/2024 - PREVIOUS INSPECTION NOTES *** NOTES ADDED BY KSANDOE 5/29/2024 3:04:39 PM *** Project will need to comply completely with the 2020 Florida Residential Building Code. All items will need to be finished prior to final inspection. Walked with superintendant today. All items are under inspection perview including exterior cleanliness
BLD - BUILDING FINAL 06/13/2024 FINAL APPROVED RSIMS
Note: 6/13/24: Both items were resolved via FaceTime Video /Audio phone app at @ 13:40 6/13/2024 - PREVIOUS INSPECTION NOTES 6/13/24: A Virtual inspection will be available IF requested at the time of scheduling the re-inspection. If requesting a Virtual Re-inspection, please schedule the re-inspection for the same day that the deficiencies will be corrected and a FaceTime or Google Meet live virtual inspection can be completed. (Pictures are not approved). 1). AHU in attic is missing the equipment label as required. Model number, etc. cannot be verified. 2). 2nd Floor AHU in attic needs location identified at the breaker for the unit. M1401.1 ________________________________________________________________________________________________________________________ 6/4/2024 - PREVIOUS INSPECTION NOTES 6/4/24: Incomplete Inspection. Too many items to list. 1st floor inspection only complete. 1). Range feed romex is outside of the wall & exposed to damage along with the outlet is not mounted to the wall. Need to check anti-tip bracket for proper anchoring. 2). Kitchen counter outlet - Right side of fridge is reading open ground and will not trip when tested. 3). Right side (Master bathroom) vanity is double trapped with both an 'S' trap feeding into a 'P" trap. 'S' traps are not code acceptable. Also, hot water is on the wrong side. 4). Kitchen sink - Hot water may be on the wrong side. Hot water is only warm. 5). Garage door safety eyes are too high. 6" max off finished floor per UL 325.6 /16CFR part 1211. Note: breaker for bathroom off of kitchen may need to be replaced as there was no power during multiple checks and suddenly turned on by itself. Condensing units both need to be checked. 5/29/2024 - PREVIOUS INSPECTION NOTES *** NOTES ADDED BY KSANDOE 5/29/2024 3:04:39 PM *** Project will need to comply completely with the 2020 Florida Residential Building Code. All items will need to be finished prior to final inspection. Walked with superintendant today. All items are under inspection perview including exterior cleanliness
BLD - BUILDING FINAL 06/04/2024 Disapproved - NO FEE RSIMS
Note: 6/4/24: Incomplete Inspection. Too many items to list. 1st floor inspection only complete. 1). Range feed romex is outside of the wall & exposed to damage along with the outlet is not mounted to the wall. Need to check anti-tip bracket for proper anchoring. 2). Kitchen counter outlet - Right side of fridge is reading open ground and will not trip when tested. 3). Right side (Master bathroom) vanity is double trapped with both an 'S' trap feeding into a 'P" trap. 'S' traps are not code acceptable. Also, hot water is on the wrong side. 4). Kitchen sink - Hot water made be on the wrong side. Hot water is only warm. 5). Garage door safety eyes are too high. 6" max off finished floor per UL 325.6 /16CFR part 1211. Note: breaker for bathroom off of kitchen may need to be replaced as there was no power during multiple checks and suddenly turned on by itself. Condensing units both need to be checked. 5/29/2024 - PREVIOUS INSPECTION NOTES *** NOTES ADDED BY KSANDOE 5/29/2024 3:04:39 PM *** Project will need to comply completely with the 2020 Florida Residential Building Code. All items will need to be finished prior to final inspection. Walked with superintendant today. All items are under inspection perview including exterior cleanliness
BLD - BUILDING FINAL 05/29/2024 Disapproved - NO FEE KSANDOE
Note: *** NOTES ADDED BY KSANDOE 5/29/2024 3:04:39 PM *** Project will need to comply completely with the 2020 Florida Residential Building Code. All items will need to be finished prior to final inspection. Walked with superintendant today. All items are under inspection perview including exterior cleanliness
INSULATION 11/20/2023 APPROVED KSANDOE
Note: 11/16/2023 - PREVIOUS INSPECTION NOTES 1. Tub drain cut out above the kitchen area needs to be sealed. 2. Rear right bedroom 2 bathroom wall seal the electrical wiring at the top plate. 3. 2" drain pipe above the family room needs to be sealed. 4. The chase in the corner at the 2nd floor front bedroom needs to have fireblocking installed to separate the chase from the attic space. 5. Seal all penetrations at 2nd floor 2x4 bottom plates, check all bottom plates.
INSULATION 11/16/2023 Disapproved - NO FEE JWALKER
Note: 1. Tub drain cut out above the kitchen area needs to be sealed. 2. Rear right bedroom 2 bathroom wall seal the electrical wiring at the top plate. 3. 2" drain pipe above the family room needs to be sealed. 4. The chase in the corner at the 2nd floor front bedroom needs to have fireblocking installed to separate the chase from the attic space. 5. Seal all penetrations at 2nd floor 2x4 bottom plates, check all bottom plates.
LATH/BRICK/ WATER BARRIER 11/01/2023 APPROVED KSANDOE
Note: Inspector Notes from Inspection 2420 Check flat straps on headers at insulation Inspector Notes from Inspection 2460 Missing flat straps on headers Inspector Notes from Inspection 2430 Details required for header over SGD Through pass to addition on right side needs framing detail, header and tie beam detail. Inspection #2460 has only been partially approved and will need to pass before all rough (MEP) can be inspected. Revision for energy calcs to show conditioning of addition has not been submitted as of this date. Electrical plan revision needed for building addition Building plan revision for work performed inside existing addition 8/7/2023 - PREVIOUS INSPECTION NOTES 1/11/2023 - PREVIOUS INSPECTION NOTES Need building plans on site for inspector use. Door is locked. Need access for inspection 8/7/23 - STAMPED SET OF COMPLETE PLANS AND DETAILS NEEDED. DOCUMENTS MUST BE APPROVED AND KEPT ON SITE 107.3,1. AND SHALL BE OPEN TO INSPECTION BY THE BUILDING OFFICIAl.
ALL ROUGH 11/01/2023 APPROVED - AS NOTED KSANDOE
Note: Check flat straps on headers at insulation Inspector Notes from Inspection 2460 Missing flat straps on headers Inspector Notes from Inspection 2430 Details required for header over SGD Through pass to addition on right side needs framing detail, header and tie beam detail. Inspection #2460 has only been partially approved and will need to pass before all rough (MEP) can be inspected. Revision for energy calcs to show conditioning of addition has not been submitted as of this date. Electrical plan revision needed for building addition Building plan revision for work performed inside existing addition 8/7/2023 - PREVIOUS INSPECTION NOTES 1/11/2023 - PREVIOUS INSPECTION NOTES Need building plans on site for inspector use. Door is locked. Need access for inspection 8/7/23 - STAMPED SET OF COMPLETE PLANS AND DETAILS NEEDED. DOCUMENTS MUST BE APPROVED AND KEPT ON SITE 107.3,1. AND SHALL BE OPEN TO INSPECTION BY THE BUILDING OFFICIAl.
ROOF SHEATHING / BRACES/TIES/DOWN CELL 11/01/2023 APPROVED - AS NOTED KSANDOE
Note: Missing flat straps on headers Inspector Notes from Inspection 2430 Details required for header over SGD Through pass to addition on right side needs framing detail, header and tie beam detail. Inspection #2460 has only been partially approved and will need to pass before all rough (MEP) can be inspected. Revision for energy calcs to show conditioning of addition has not been submitted as of this date. Electrical plan revision needed for building addition Building plan revision for work performed inside existing addition 8/7/2023 - PREVIOUS INSPECTION NOTES 1/11/2023 - PREVIOUS INSPECTION NOTES Need building plans on site for inspector use. Door is locked. Need access for inspection 8/7/23 - STAMPED SET OF COMPLETE PLANS AND DETAILS NEEDED. DOCUMENTS MUST BE APPROVED AND KEPT ON SITE 107.3,1. AND SHALL BE OPEN TO INSPECTION BY THE BUILDING OFFICIAl.
FRAMING 08/09/2023 APPROVED - AS NOTED KSANDOE
Note: Details required for header over SGD Through pass to addition on right side needs framing detail, header and tie beam detail. Inspection #2460 has only been partially approved and will need to pass before all rough (MEP) can be inspected. Revision for energy calcs to show conditioning of addition has not been submitted as of this date. Electrical plan revision needed for building addition Building plan revision for work performed inside existing addition 8/7/2023 - PREVIOUS INSPECTION NOTES 1/11/2023 - PREVIOUS INSPECTION NOTES Need building plans on site for inspector use. Door is locked. Need access for inspection 8/7/23 - STAMPED SET OF COMPLETE PLANS AND DETAILS NEEDED. DOCUMENTS MUST BE APPROVED AND KEPT ON SITE 107.3,1. AND SHALL BE OPEN TO INSPECTION BY THE BUILDING OFFICIAl.
FRAMING 08/07/2023 Disapproved - NO FEE FWILLIS
Note: 1/11/2023 - PREVIOUS INSPECTION NOTES Need building plans on site for inspector use. Door is locked. Need access for inspection 8/7/23 - STAMPED SET OF COMPLETE PLANS AND DETAILS NEEDED. DOCUMENTS MUST BE APPROVED AND KEPT ON SITE 107.3,1. AND SHALL BE OPEN TO INSPECTION BY THE BUILDING OFFICIAl.
PLUMBING 1ST ROUGH UNDERGROUND 06/13/2023 Disapproved -FEE REQUIRED MGIBSON
Note: NEED TO LIST CORRECT PLUMBING SUB CONTRACTOR, NEED TO REPLACE TEST CAP WITH SCHEDULE 40 HARD CAP, NEED SHOCK ARRESTOR AT ICE MAKER BOX, NO TEST ON WASTE AND VENT, BUILDING DEPARTMENT DOESN'T DO SINGLE TRADE INSPECTIONS FOR 1&2 FAMILY DWELLINGS AN ALL ROUGH INSPECTION IS WHAT NEEDS TO BE SCHEDULED
HVAC ROUGH 06/13/2023 Disapproved - NO FEE KSANDOE
Note: Installed ducting does not match approved duct layout on energy calcs. Submit revised energy calcs with installed layout or install approvedd duct map.
ELECTRIC 2ND ROUGH 06/13/2023 APPROVED - AS NOTED RMARTIN
Note: THE ALL ROUGH INSPECTION NEEDS TO BE SCHEDULED, NEED TO HAVE ELECTRICIAN LOCK OUT MAIN BREAKER, SHOULD HAVE NO POWER TO GARAGE PANEL (SAFETY HAZARD)
ROOF VALLEY & METAL 04/24/2023 APPROVED KSANDOE
ROOF SHEATHING / BRACES/TIES/DOWN CELL 02/03/2023 PARTIALLY APPROVED KSANDOE
Note: Inspection conducted for dry in purposes only. Roof and wall sheathing passed. Framing inspection to follow
FRAMING 01/11/2023 Disapproved -FEE REQUIRED KSANDOE
Note: Need building plans on site for inspector use. Door is locked. Need access for inspection

Review History

Department Status Date In Date Out
MECH COMPLETE 05/13/2024 05/17/2024
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
BLD COMPLETE 10/24/2023 10/26/2023
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
BLD HOLD 10/09/2023 10/11/2023
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Repeat comment: 3. Provide return air out of added room (Provide new duct layout)
ELEC COMPLETE 10/09/2023 10/11/2023
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
BLD HOLD 08/23/2023 08/29/2023
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM 1. Provide details on plans for added doorway into new arae. 2. Upgrade electrical plan and floor plan to show added room.+ 3. Provide return air out of added room
MECH COMPLETE 07/06/2023 07/10/2023
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
BLD COMPLETE 07/06/2023 07/10/2023
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
MECH HOLD 06/20/2023 06/22/2023
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Provide Engineered details with all support details for trusses where AHU is located in attic.
BLD COMPLETE 09/06/2022 09/07/2022
Note: Released By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM
ENGIN1 COMPLETE 09/06/2022 09/07/2022
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
ZON COMPLETE 07/11/2022 07/12/2022
Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM
MECH COMPLETE 07/11/2022 07/11/2022
Note: Released By: CHRIS PISCITELLI - (386)986-3782 - CPISCITELLI@PALMCOASTGOV.COM
ELEC COMPLETE 05/18/2022 05/19/2022
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
MECH HOLD 05/18/2022 05/19/2022
Note: Held By: CHRIS PISCITELLI - (386)986-3782 - CPISCITELLI@PALMCOASTGOV.COM Provide Energy Calcs heatload and duct layout
ZON HOLD 05/18/2022 05/19/2022
Note: Held By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM Pitched roofs: shall have a minimum slope of 5:12 (five inches vertical rise for every 12 inches horizontal run) and shall have an overhang beyond the building wall; however, the overhang shall not encroach into an easement. Please make changes accordingly. Elevation sheet: please provide elevation sheet with all changes being made Garage doors shown do not meet the code. Please install the standard residential Gargage doors allowed by code. Barn style not allowed. Provide a landscape plan. that matches you site plan. Site plan submitted originally looks different *Once this corrections come in please get with supervisor (Tracey for approval)**
BLD COMPLETE 05/18/2022 05/20/2022
Note: Released By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM
BLD HOLD 04/07/2022 04/11/2022
Note: Held By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM All comments below per the 2020 Florida Building Code REVIEW COMMENTS: 1. Plans submitted are for a fire repair. Provide engineer to provide structural elevation. Elevation is to note Less than Substantial Structural Damage or Substantial Damage. Per 406 FBCE. 2. Revise the submitted plans to show all work to be performed. As noted above, this is a fire repair. FBC107.
ELEC HOLD 04/07/2022 04/07/2022
Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. Outlets in laundry and outside need to be GFCI protected. NEC 2017 210.8 2. Need to show existing size of service and prove that it can accommodate the new addition.
MECH HOLD 04/07/2022 04/07/2022
Note: Held By: CHRIS PISCITELLI - (386)986-3782 - CPISCITELLI@PALMCOASTGOV.COM Provide scope of work for mechanical.
PLUM COMPLETE 04/07/2022 04/11/2022
Note: Released By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM
ZON HOLD 04/07/2022 04/07/2022
Note: Held By: CINDY CHIRI-GONCALVES - - CGONCALVES@PALMCOASTGOV.COM Pitched roofs: shall have a minimum slope of 5:12 (five inches vertical rise for every 12 inches horizontal run) and shall have an overhang beyond the building wall; however, the overhang shall not encroach into an easement. Please make changes accordingly. Elevation sheet: please provide elevation sheet with all changes being made Garage doors shown do not meet the code. Please install the standard residential Gargage doors allowed by code. Barn style not allowed. Provide a landscape plan. Residential homes shall provide a foundation plantings consisting of 16 shrubs on interior lots. Eight shrubs shall be planted in front of home and four shrubs planted on each side of the home. The corners of the home shall be wrapped with shrubbery or have an understory tree planted there. *All of these required shrubs shall be planted between two and one half and eight feet of the homes foundation.* Please provide the proposed sod being laid down. Also if Irrigation will be needed **Once this corrections come in please get with supervisor (Tracey for approval)**

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
EXTENSION ¤40.00 05/28/2024
EXTENSION ¤40.00 05/28/2024
PLAN REVIEW - REVISION ¤32.50 05/28/2024
PLAN REVIEW - REVISION ¤32.50 05/28/2024
PLAN REVIEW - REVISION ¤32.50 05/28/2024
REINSPECTION RESIDENTIAL ¤40.00 05/28/2024
REINSPECTION RESIDENTIAL ¤40.00 05/28/2024
CONTRACTOR CHANGE ¤20.00 05/28/2024
PLAN REVIEW - REVISION ¤32.50 09/16/2022
INSPECTION - RESIDENTIAL ¤275.00 07/14/2022
PLAN REVIEW - RESIDENTIAL ¤78.00 07/14/2022
SURCHARGE FS 533.721 ¤3.44 07/14/2022
SURCHARGE - FS 468.631 ¤5.15 07/14/2022
SITE PLAN 30 ¤30.00 07/14/2022
ADMINISTRATIVE RESIDENTIAL ¤30.00 07/14/2022
Fees Total Due: ¤0.00 Total Paid: ¤731.59