I want to search for...

Permit #2022040313

Permit Details

Status: FINAL

Parcel Id: 07-11-31-7006-00030-0170
Block: 00030
Subdivision: 2213 - SECTION 6-FLORIDA PARK
Job Phone: (386)527-6203
Location Address: 16 FLEMING CT
Type: PO - POOL
Issue Date: 05/17/2022
NOC: RECORDED
Applicant name: BRIAN ROBERT LENOIS
Owner: KAZSAMER ANDRAS & VIKTORIA H&W

Address

16 FLEMING CT

PALM COAST, FL 32137

Lot: 0170
Contracted Stated Job Value: ¤46,281.00
Job Description: POOL ONLY (EXISTING FFENCE)
Type: CN

Contractor

ARTESIAN POOLS OF EAST FLORIDA, INC.
Status Location Address State License Number Phone Fax
ACTIVE

762 S NOVA ROAD

DAYTONA BEACH , FL 32114

CPC1456573 (Exp: 08/31/2026) (386)586-5569 (386)258-3702

Sub Contractors

JEFFREY ADAM MCGREGOR
Status Location Address State License Number Phone Fax
ACTIVE

1312 YORKTOWN STREET

DELAND , FL 32724

EC13005662 (Exp: 08/31/2026) 386-736-7475 386-785-1503

Inspection History

Type Request Date Result Inspector
POOL FINAL 07/15/2024 FINAL APPROVED KSANDOE
Note: 11/7/2023 - PREVIOUS INSPECTION NOTES 6/20/2023 - PREVIOUS INSPECTION NOTES 6/15/2023 - PREVIOUS INSPECTION NOTES 06-15-2023 Rang door bell. No inspection, doors locked, need access for inspection. FBC R110.1 06-20-2023 1. TDH calculations, permit, and approved drawings not on site. 2. Pool alarm not active. Fall protection needed at end of paver deck and steps with hand rails. 11-7-2023 1. Guards required at pool deck not per code. FALL PROTECTION REQUIRED GUARDS. R312.1.3 GUARDS SHALL NOT HAVE OPENINGS THAT ALLOW A 4” SPHERE TO PASS THROUGH. 2. Landing needed at left screen door opening. R311.3 Floors and landings at exterior doors 3. Risers. R311.7.5.1Risers. Right side of steps to pool and steps to canal. Check all. 4. Nosings needed at steps. Check all. R311.7.5.3 Nosings at treads, landings and floors of stairways shall have a radius of curvature at the nosing not greater than 9/16 inch (14 mm) or a bevel not exceeding 1/2 inch 5. Only one gauge is installed to determine TDH. 6. Inspection stopped.
POOL FINAL 11/07/2023 Disapproved -FEE REQUIRED AGAETANO
Note: 6/20/2023 - PREVIOUS INSPECTION NOTES 6/15/2023 - PREVIOUS INSPECTION NOTES 06-15-2023 Rang door bell. No inspection, doors locked, need access for inspection. FBC R110.1 06-20-2023 1. TDH calculations, permit, and approved drawings not on site. 2. Pool alarm not active. Fall protection needed at end of paver deck and steps with hand rails. 11-7-2023 1. Guards required at pool deck not per code. FALL PROTECTION REQUIRED GUARDS. R312.1.3 GUARDS SHALL NOT HAVE OPENINGS THAT ALLOW A 4” SPHERE TO PASS THROUGH. 2. Landing needed at left screen door opening. R311.3 Floors and landings at exterior doors 3. Risers. R311.7.5.1Risers. Right side of steps to pool and steps to canal. Check all. 4. Nosings needed at steps. Check all. R311.7.5.3 Nosings at treads, landings and floors of stairways shall have a radius of curvature at the nosing not greater than 9/16 inch (14 mm) or a bevel not exceeding 1/2 inch 5. Only one gauge is installed to determine TDH. 6. Inspection stopped.
POOL FINAL 06/20/2023 Disapproved -FEE REQUIRED AGAETANO
Note: 6/15/2023 - PREVIOUS INSPECTION NOTES 06-15-2023 Rang door bell. No inspection, doors locked, need access for inspection. FBC R110.1 06-20-2023 1. TDH calculations, permit, and approved drawings not on site. 2. Pool alarm not active. Fall protection needed at end of paver deck and steps with hand rails.
POOL FINAL 06/15/2023 Disapproved - NO FEE AGAETANO
Note: 06-15-2023 Rang door bell. No inspection, doors locked, need access for inspection. FBC R110.1
U -UTILITY RESIDENTIAL FINAL 06/15/2023 FINAL APPROVED DHANEY
ROW- FINAL SURVEY/GRADING CERTIFICATION 06/14/2023 APPROVED EMADISON
ROW FIELD SURVEY /GRADING CERTIFICATION 06/14/2023 APPROVED EMADISON
ROW - FINAL INSPECTION 06/14/2023 APPROVED EMADISON
ELECTRIC AND ALARM 02/03/2023 APPROVED AGAETANO
Note: 1/4/2023 - PREVIOUS INSPECTION NOTES 01-04-2023 Alarm not visible.
ELECTRIC AND ALARM 01/04/2023 CANCELLED BY APPLICANT WEB
ELECTRIC AND ALARM 01/04/2023 Disapproved - NO FEE AGAETANO
Note: 01-04-2023 Alarm not visible.
POOL DECK 11/23/2022 APPROVED AGAETANO
Note: Inspector Notes from Inspection 2600 THIS IS A REINSPECTION Minimum PSI not met PRESSURE TEST R4501.12.1. 35psi. Pressure gauge not visible. 08-22-2022 - Contractor not using standard system.
STEEL AND GROUND 08/22/2022 APPROVED - AS NOTED AGAETANO
Note: THIS IS A REINSPECTION Minimum PSI not met PRESSURE TEST R4501.12.1. 35psi. Pressure gauge not visible. 08-22-2022 - Contractor not using standard system.
STEEL AND GROUND 08/19/2022 Disapproved - NO FEE AGAETANO
Note: Minimum PSI not met PRESSURE TEST R4501.12.1. 35psi. Pressure gauge not visible.

Review History

Department Status Date In Date Out
BADMIN INFORMATION 06/03/2024 06/03/2024
Note: Marked INFORMATION By: BARBIE BEMBRY - (386)986-3780 - BUILDINGDIVISION@PALMCOASTGOV.COM A 45 day extension was granted,no additional extensions will be granted.
ZON COMPLETE 05/10/2022 05/10/2022
Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM
SW1 COMPLETE 05/10/2022 05/16/2022
Note: Released By: ROBERT GROSS - (386)986-4769 - RGROSS@PALMCOASTGOV.COM
ZON HOLD 04/22/2022 04/22/2022
Note: Held By: JACQUELINE GONZALEZ - (386)986-3751 - JGONZALEZ@PALMCOASTGOV.COM Repeat comments: Revise site plan to show dimension of the pool deck.
BLD COMPLETE 04/22/2022 04/22/2022
Note: Released By: FRED REODICA - (386)986-4734 - FREODICA@PALMCOASTGOV.COM
SW1 HOLD 04/22/2022 04/28/2022
Note: Held By: PARREN FLANAGAN - - PFLANAGAN@PALMCOASTGOV.COM still need FFE on pool deck
BLD HOLD 04/07/2022 04/08/2022
Note: Held By: FRED REODICA - (386)986-4734 - FREODICA@PALMCOASTGOV.COM Clarify the pump hp to be used per FBC 7th Ed. Sec. 107.3. The Simplified TDH calculation shows 1 hp (Pentair model SF-N2-1A) but pool plan specs (item 8) shows 2 hp.
ELEC COMPLETE 04/07/2022 04/07/2022
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
MECH COMPLETE 04/07/2022 04/07/2022
Note: Released By: CHRIS PISCITELLI - (386)986-3782 - CPISCITELLI@PALMCOASTGOV.COM
SW1 HOLD 04/07/2022 04/11/2022
Note: Held By: PARREN FLANAGAN - - PFLANAGAN@PALMCOASTGOV.COM NEED TO HAVE FFE OF POOL DECK
ZON HOLD 04/07/2022 04/08/2022
Note: Held By: KATIE TAING - (386)986-3751 - KTAING@PALMCOASTGOV.COM Please provide the dimensions of the pool deck on the site plan.

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
ADMINISTRATIVE - EXTENSION ¤40.00 07/12/2024
EXTENSION ¤40.00 07/12/2024
REINSPECTION RESIDENTIAL ¤40.00 07/12/2024
REINSPECTION RESIDENTIAL ¤40.00 11/06/2023
SURCHARGE FS 533.721 ¤2.26 05/17/2022
SURCHARGE - FS 468.631 ¤3.39 05/17/2022
SW ENG INSPECTION 40 ¤40.00 05/17/2022
SW ENG - REVIEW 20 ¤20.00 05/17/2022
SITE PLAN 30 ¤30.00 05/17/2022
INSPECTION- POOL ¤160.00 05/17/2022
PLAN REVIEW - RESIDENTIAL ¤65.00 05/17/2022
ADMINISTRATIVE RESIDENTIAL ¤30.00 05/17/2022
Fees Total Due: ¤0.00 Total Paid: ¤510.65