I want to search for...

Permit #2022040713

Permit Details

Status: FINAL

Parcel Id: 07-11-31-7015-00030-1900
CONDITIONED SPACE: 575 sqft
GARAGE: 396 sqft
Total Square Footage: 971 sqft
Block: 00030
Subdivision: 2194 - SECTION 15-COUNTRY CLUB COVE
Job Phone: 305-799-4886
Location Address: 26 CHEYENNE CT
Type: BA - BUILDING ADDITION
Issue Date: 07/01/2022
NOC: RECORDED
Applicant name: JOHN EDWARD JAMES
Owner: SCHULTZ JOSEPH JASON & DANA GRACE VAN DYKE TIC

Address

26 CHEYENNE COURT

PALM COAST, FL 32137

Lot: 1900
Contracted Stated Job Value: ¤100,000.00
Job Description: Garage & Shop Addition
Type: CN

Contractor

JAMES COMMERCIAL DEVELOPMENT INC
Status Location Address State License Number Phone
ACTIVE

9950 KIRCHHERR

WEST PALM BEACH, FL 33411

CGC1514256 (Exp: 08/31/2026) 305-799-4886

Sub Contractors

MANUEL JOSE LINARES
Status Location Address State License Number Phone
CANCEL

5402 NW 27TH WAY

TAMARAC, FL 33309

EC13007509 (Exp: 08/31/2022) 954-325-4555
DELROY L TOMLINSON
Status Location Address Mailing Address State License Number
INACTIVE

1451 W CYPRESS CREEK RD

FORT LAUDERDALE, FL 33309

STE 300

FORT LAUDERDALE, FL 33309

CAC057248 (Exp: 08/31/2024)

Inspection History

Type Request Date Result Inspector
BLD - BUILDING FINAL 08/28/2024 FINAL APPROVED KSANDOE
U -UTILITY RESIDENTIAL FINAL 08/27/2024 FINAL APPROVED LFITZGERALD
ROW - FINAL APRON (AFTER POUR) 08/26/2024 APPROVED EMADISON
ROW- FINAL SURVEY/GRADING CERTIFICATION 08/26/2024 APPROVED EMADISON
Note: 8/7/2024 - PREVIOUS INSPECTION NOTES ** Survey must be signed, dated and sealed by an actively licensed Florida Professional Surveyor. **Drainage from the structure is to be a 6 inch (5%) minimum slope for the first 10’.(I)?The subject lots drainage must not negatively impact any adjacent property. ** FFE of adjacent improved properties. ** FINAL ELEVATIONS ON A 20 FT GRID INSIDE OF PROPERTY LINES ** Elevations on all adjacent properties at a minimum of 20-foot intervals, on a 10 foot offset, outside the property lines. **Elevations on all adjacent property lines at 20-foot intervals. (B)?All drainage and topographical features must be clearly depicted including easementsand top of bank locations.
ROW FIELD SURVEY /GRADING CERTIFICATION 08/26/2024 APPROVED EMADISON
ROW - FINAL INSPECTION 08/26/2024 APPROVED EMADISON
ROW- FINAL SURVEY/GRADING CERTIFICATION 08/07/2024 Disapproved - NO FEE EMADISON
Note: ** Survey must be signed, dated and sealed by an actively licensed Florida Professional Surveyor. **Drainage from the structure is to be a 6 inch (5%) minimum slope for the first 10’.(I)?The subject lots drainage must not negatively impact any adjacent property. ** FFE of adjacent improved properties. ** FINAL ELEVATIONS ON A 20 FT GRID INSIDE OF PROPERTY LINES ** Elevations on all adjacent properties at a minimum of 20-foot intervals, on a 10 foot offset, outside the property lines. **Elevations on all adjacent property lines at 20-foot intervals. (B)?All drainage and topographical features must be clearly depicted including easementsand top of bank locations.
PROJECT STATUS (OFFICE USE) 07/10/2024 APPROVED KSANDOE
Note: 5/6/2024 - PREVIOUS INSPECTION NOTES *** NOTES ADDED BY KSANDOE 5/6/2024 1:48:10 PM *** Homeowner requested. 1.) Attic ladder is unsafe for use. Bottom cord of truss has been cut to install attic ladder. Engineering repair required for truss. Homeowneer advised not to use ladder. 2.) Rear french door not sealed at base allowing water to enter addition. 3.) Rear french door has had tapcons removed and is not mounted safely. 4.) Concrete block fire rated wall has not been built. Plan revision required. 5.) Roof over breezeway is missing flashing at vertical roof termination allowing water infestation. 6.) Soffit missing over entry to main home. 7.) Roof under breezeway on main home is incomplete and must be sealed and shingled properly. Add by Ken. See Ken for details
PROJECT STATUS (OFFICE USE) 05/06/2024 Disapproved - NO FEE KSANDOE
Note: *** NOTES ADDED BY KSANDOE 5/6/2024 1:48:10 PM *** Homeowner requested. 1.) Attic ladder is unsafe for use. Bottom cord of truss has been cut to install attic ladder. Engineering repair required for truss. Homeowneer advised not to use ladder. 2.) Rear french door not sealed at base allowing water to enter addition. 3.) Rear french door has had tapcons removed and is not mounted safely. 4.) Concrete block fire rated wall has not been built. Plan revision required. 5.) Roof over breezeway is missing flashing at vertical roof termination allowing water infestation. 6.) Soffit missing over entry to main home. 7.) Roof under breezeway on main home is incomplete and must be sealed and shingled properly. Add by Ken. See Ken for details
INSULATION 02/02/2024 APPROVED KSANDOE
ALL ROUGH 02/01/2024 APPROVED KSANDOE
Note: 1/31/2024 - PREVIOUS INSPECTION NOTES 11/7/2023 - PREVIOUS INSPECTION NOTES Submit revision for electrical layout. No mechanical installed Missing nailing on straps throughout No energy calcs or product approvals on site Smoke barrier not installed Window and door nailing passed.
ALL ROUGH 01/31/2024 CANCELLED BY APPLICANT AGAETANO
Note: 11/7/2023 - PREVIOUS INSPECTION NOTES Submit revision for electrical layout. No mechanical installed Missing nailing on straps throughout No energy calcs or product approvals on site Smoke barrier not installed Window and door nailing passed.
ALL ROUGH 11/07/2023 PARTIALLY APPROVED KSANDOE
Note: Submit revision for electrical layout. No mechanical installed Missing nailing on straps throughout No energy calcs or product approvals on site Smoke barrier not installed Window and door nailing passed.
LATH/BRICK/ WATER BARRIER 11/07/2023 APPROVED KSANDOE
ROW- PRE-APRON (PRE-POUR) 05/24/2023 APPROVED EMADISON
Note: ** 05/24/23 READY TO POUR BUILDERS RESPONSIBILITY TO ENSURE CULVERT ELEVATION IS WITHIN TOLERANCE BEFORE THE POUR IN THE EVENT OF RAIN CHECK COMPACTION OF MATERIAL **MAKE SURE THERE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL _____________________________________________________________________________________________________________________ 5/19/2023 - PREVIOUS INSPECTION NOTES 05/19/23= FOOTERS HAVE WASHED IN NEED TO BE DUG OUT, PIPE SHOULD BE DUG OUT 6 INCHES DEEP BY 6 INCHES LONG UNDER EACH END OF THE PIPE. ORGANICS NEED TO BE REMOVED FROM THE POUR AREA. CULVERT PIPE IS GOOD. DRAWING 300 E RESIDENTIAL CULVERT DETAIL
ROW- PRE-APRON (PRE-POUR) 05/19/2023 Disapproved - NO FEE GBERTOLA
Note: 05/19/23= FOOTERS HAVE WASHED IN NEED TO BE DUG OUT, PIPE SHOULD BE DUG OUT 6 INCHES DEEP BY 6 INCHES LONG UNDER EACH END OF THE PIPE. ORGANICS NEED TO BE REMOVED FROM THE POUR AREA. CULVERT PIPE IS GOOD. DRAWING 300 E RESIDENTIAL CULVERT DETAIL
WALL SHEATHING 04/27/2023 APPROVED TSTAUFFACHER
ROOF SHEATHING / BRACES/TIES/DOWN CELL 04/27/2023 Disapproved - NO FEE TSTAUFFACHER
Note: Provide engineering for tiedowns on gable end-header and ridgepole for breezeway at house and addition
ROOF SHEATHING 04/27/2023 APPROVED TSTAUFFACHER
Note: OK to shingle
TIE BEAM / LINTEL 11/17/2022 APPROVED DCUSHING
Note: 9/22/2022 - PREVIOUS INSPECTION NOTES Inspector Notes from Inspection 2250 THIS IS A REINSPECTION Compaction test and termite bond not posted. TERMITE INSPECTION (WALLS/GRADE) R318.7 INSPECTION FOR TERMITES. SHALL NOT BE LESS THAN 6" BETWEEN WALL COVERINGS AND FINAL GRADE, 07-28-2022 - Terminte bond and compaction letter on site. Contractor will submit to building department and proceed at own risk. 09-22-2022 1. A1 Note A on back of building indicates four windows. Two new openings have been installed and the third window has been relocated. Pllease submit a revision to the building department for the alterations made. New energy calculations will be required. 2. Please replace the pieced lintel on the right side entry door or submit a revision/engineering to the building department. All items addressed
TIE BEAM / LINTEL 09/22/2022 Disapproved - NO FEE AGAETANO
Note: Inspector Notes from Inspection 2250 THIS IS A REINSPECTION Compaction test and termite bond not posted. TERMITE INSPECTION (WALLS/GRADE) R318.7 INSPECTION FOR TERMITES. SHALL NOT BE LESS THAN 6" BETWEEN WALL COVERINGS AND FINAL GRADE, 07-28-2022 - Terminte bond and compaction letter on site. Contractor will submit to building department and proceed at own risk. 09-22-2022 1. A1 Note A on back of building indicates four windows. Two new openings have been installed and the third window has been relocated. Pllease submit a revision to the building department for the alterations made. New energy calculations will be required. 2. Please replace the pieced lintel on the right side entry door or submit a revision/engineering to the building department.
MONOLITHIC SLAB 07/28/2022 APPROVED - AS NOTED AGAETANO
Note: THIS IS A REINSPECTION Compaction test and termite bond not posted. TERMITE INSPECTION (WALLS/GRADE) R318.7 INSPECTION FOR TERMITES. SHALL NOT BE LESS THAN 6" BETWEEN WALL COVERINGS AND FINAL GRADE, 07-28-2022 - Terminte bond and compaction letter on site. Contractor will submit to building department and proceed at own risk.
MONOLITHIC SLAB 07/14/2022 Disapproved - NO FEE AGAETANO
Note: Compaction test and termite bond not posted. TERMITE INSPECTION (WALLS/GRADE) R318.7 INSPECTION FOR TERMITES. SHALL NOT BE LESS THAN 6" BETWEEN WALL COVERINGS AND FINAL GRADE,

Review History

Department Status Date In Date Out
BLD COMPLETE 06/20/2024 06/25/2024
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Engineered letter will be approved, but previous comments were not addressed. REPEAT COMMENTS: 1. 1 hour rated partition requires a 3/4 hour rated door per FBC, Building Table 716.5 2. Please revise door #3 on door schedule. Provide product approval.
ZON COMPLETE 06/20/2024 06/20/2024
Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM NO zoning changes
BLD HOLD 05/29/2024 06/04/2024
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Engineered letter will be approved, but previous comments were not addressed. REPEAT COMMENTS: 1. 1 hour rated partition requires a 3/4 hour rated door per FBC, Building Table 716.5 2. Please revise door #3 on door schedule. Provide product approval.
BLD HOLD 05/13/2024 05/17/2024
Note: Held By: ALPHANETTE WATERS - (386)986-2624 - AWATERS@PALMCOASTGOV.COM 1. 1 hour rated partition requires a 3/4 hour rated door per FBC, Building Table 716.5 2. Please revise door #3 on door schedule. Provide product approval.
ZON COMPLETE 05/13/2024 05/13/2024
Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM
ELEC COMPLETE 01/30/2024 01/30/2024
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
ELEC HOLD 01/02/2024 01/03/2024
Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. Ned light and switch by exterior door. NEC 2017 210.70 2. Need to show lights in the garage and what type. NEC 2017 210.70
ZON COMPLETE 05/16/2023 05/16/2023
Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM
BLD COMPLETE 04/11/2023 04/18/2023
Note: Released By: PATRICK BUCKLEY - (386)986-3786 - PBUCKLEY@PALMCOASTGOV.COM
ENGIN1 COMPLETE 03/01/2023 03/01/2023
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
SW1 COMPLETE 03/01/2023 03/08/2023
Note: Released By: ROBERT GROSS - (386)986-4769 - RGROSS@PALMCOASTGOV.COM
ZON COMPLETE 03/01/2023 03/01/2023
Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM
SWALE COMPLETE 03/01/2023 03/08/2023
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
BLD COMPLETE 11/15/2022 11/15/2022
Note: Released By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM
ZON COMPLETE 11/09/2022 11/09/2022
Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM
BLD HOLD 11/09/2022 11/09/2022
Note: Held By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM All comments below per the 2020 Florida Building Code PLAN REVIEW COMMENTS: 1.Provide a product approval number for proposed sliding door.
BLD HOLD 10/31/2022 11/02/2022
Note: Held By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM All comments below per the 2020 Florida Building Code – Plumbing REVIEW COMMENTS: 1. Product approval for the sectional roll up door is for 10 foot to 20 foot door. Revised plans show a proposed 8 foot door. Please provide a product approval for the 8 foot door.
ZON HOLD 10/31/2022 11/01/2022
Note: Held By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM Cannot have a roll up garage door facing the canal. All windows and doors facing the canal must have banding.
ELEC COMPLETE 06/29/2022 06/29/2022
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
ZON COMPLETE 06/28/2022 06/28/2022
Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM
ELEC HOLD 06/28/2022 06/28/2022
Note: Held By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM Submit new electrical plan
BLD COMPLETE 06/28/2022 06/28/2022
Note: Released By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM
SW1 COMPLETE 06/28/2022 06/29/2022
Note: Released By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM
ELEC HOLD 06/27/2022 06/27/2022
Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM Submit new electrical plan
BLD HOLD 06/27/2022 06/27/2022
Note: Held By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM All comments below per the 2020 Florida Building Code PLAN REVIEW COMMENTS: 1. Provide revised Cover Sheet for the correct project. 2. Floor Plan was revised. Structural Drawing on Sheet S-1 still references the older design. Revise all sheets to reflect the changes. FBC 107.3.
ELEC COMPLETE 06/27/2022 06/27/2022
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
MECH COMPLETE 06/27/2022 06/27/2022
Note: Released By: CHRIS PISCITELLI - (386)986-3782 - CPISCITELLI@PALMCOASTGOV.COM
SW1 HOLD 06/24/2022 06/27/2022
Note: Held By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM NEED TO HAVE ELEVATIONS SO WE CAN DETERMIND THE DRAINAGE FOR THE LOT YOU ARE PUTTING THE NEW ADDITION
ZON HOLD 06/24/2022 06/27/2022
Note: Held By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM Please submit a new updated site plan with the new layout. Please turn in original signed and notarized termination of easement agreement that was emailed to you
ELEC COMPLETE 06/09/2022 06/09/2022
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
PLFM COMPLETE 06/08/2022 06/08/2022
Note: Released By: JORDAN MYERS, C.F.M - (386)986-2320 - JMYERS@PALMCOASTGOV.COM Per the FLOODZONE exhibit submitted on 6/7/22, the addition does not fall within the SFHA. No elevation certificates will be required.
ELEC HOLD 06/08/2022 06/08/2022
Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM Garage outlets must be on there own 20 amp circuit. NEC 2017 210.11 (C) (4). This was in the first set of comments so you cannot have just one circuit feedingb the new garage must have at least two. New plans only show one.
ZON HOLD 06/08/2022 06/08/2022
Note: Held By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM TOTAL garage space shall not exceed 50 percent of the total living area of the PRINCIPAL dwelling unit. This includes the newly added garage and existing garage. 397 is all that would be allowed for a garage. Maximum depth for a garage is 30ft. This addition still has garage doors so it is still calculated as garage space. We are creating the agreement for terminating the easement as soon as completed will email so owners can sign and have notarized. Original copy will need to be turned in to us for recording.
SW1 HOLD 06/08/2022 06/15/2022
Note: Held By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM THINGS NEEDED ON YOUR SITE PLAN (1) FLOW AROOW TO DETERMIND DRAINAGE (2) NEED TO HAVE PROPOSED ELEVATIONS ON ALL FOUR CORNERS OF STRUCTURE (3) NEED PROPOSED ELEVATIONS IN LOT SO WE CAN SEE IF WATER WILL NOT BE IMPACTING LOTS AROUND YOUR LOT (4) NEED TO HAVE A BENCH MARK FOR THE SITE THAT IS IN 88DATUM
BLD COMPLETE 06/08/2022 06/08/2022
Note: Released By: CHRIS PISCITELLI - (386)986-3782 - CPISCITELLI@PALMCOASTGOV.COM
PLFM HOLD 05/27/2022 05/27/2022
Note: Held By: JORDAN MYERS, C.F.M - (386)986-2320 - JMYERS@PALMCOASTGOV.COM The exhibit titled FLOODZONE does include the flood zone line, however it does not show the proposed addition. Please revise.
BLD HOLD 05/27/2022 05/31/2022
Note: Held By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM All comments below per the 2020 Florida Building Code – Residential REVIEW COMMENTS: 1. OK 2. OK 3. OK 4. OK 5. OK 6. OK 7. Provide Product Approvals for Wood Connectors, Wood Anchors, Truss Plates,.
SW1 HOLD 05/27/2022 05/27/2022
Note: Held By: EDWARD MADISON - - EMADISON@PALMCOASTGOV.COM NEED TO REVIEW THE STORMWATER CHECK LIST, ENSURE THAT ALL PERTINENT INFORMATION IS ON SITE PLAN.
ELEC HOLD 05/27/2022 05/27/2022
Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. Need to show wire size and breaker size of circuit feeding the garage. 2nd REQUEST
MECH COMPLETE 05/27/2022 05/27/2022
Note: Released By: CHRIS PISCITELLI - (386)986-3782 - CPISCITELLI@PALMCOASTGOV.COM
ZON HOLD 05/27/2022 05/27/2022
Note: Held By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM TOTAL garage space shall not exceed 50 percent of the total living area of the PRINCIPAL dwelling unit. This includes the newly added garage and existing garage. 397 is all that would be allowed for a garage. Please provide material and width of driveway on site plan Please provide a termination of easement application Additional foundation plantings required along rear facing canal Please provide a site plan showing the platted easement with the garage addition that is crossing the easement that is being terminated
BLD HOLD 04/19/2022 04/19/2022
Note: Held By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM All comments below per the 2020 Florida Building Code – Residential REVIEW COMMENTS: 1. Notes on the Cover Sheet and Sheet A-1 references ASCE 7-10. This Reference Standard is from a previous Code. A revision is required to reference the correct Code reference from the current Code. 2. Roof Attachment Plan is also from a previous Code. A revision is required to reflect the current standards of Figure R301.2(7). 3. Shingle attachments reference the FBRC 2015 5th Edition. As per my previous comments, this reference is from 2 previous Code cycles. A revision is required to reference the current Code. FBCR [A]107. 4. General Note #6 on the Detail Sheet references the 2010 FBC. FBC 107. 5. General Note #11 on Detail Sheet references the 2014 FBC 5th Edition. 6. HVAC Note #9 references the 2017 Energy Code. FBC 107 7. Provide Product Approvals for Wood Connectors, Wood Anchors and Truss Plates.
PLFM HOLD 04/18/2022 04/18/2022
Note: Held By: JORDAN MYERS, C.F.M - (386)986-2320 - JMYERS@PALMCOASTGOV.COM Please provide updated Site Plan/Survey that shows the flood zones on the property. Should any part of the addition or machinery fall within the flood zone, elevation certificates will be required at construction drawings, foundation, and final.
BLD HOLD 04/14/2022 04/14/2022
Note: Held By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM All comments below per the 2020 Florida Building Code REVIEW COMMENTS: 1. Floor & Roof Live Loads are for an A-1 Assembly – Assembly & Theaters. The proposed is a Residential Boat House. Provide loads for the correct structure. FBC 107. 2. Provide boat lift manufactures specifications. FBC 107 3. Provide all required product approvals for furnished materials including, but not limited to: a) Wood Connector b) Wood Anchors FBC 1709.9.1, FBC 1709.10.1, FBC 1512.2.1, FBC 2410.4, FBC 2315.1.11, Florida Statute 553.842.
ELEC HOLD 04/14/2022 04/14/2022
Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. Need to show wire size and breaker size of circuit feeding the garage. 2. Need to have outlets in garage. NEC 2017 210.52 (G) (1) 3. Garage outlets must be on there own 20 amp circuit. NEC 2017 210.11 (C) (4)
MECH HOLD 04/14/2022 04/14/2022
Note: Held By: CHRIS PISCITELLI - (386)986-3782 - CPISCITELLI@PALMCOASTGOV.COM 1. Indoor design temp on heatload must be a minimum of 75 degrees per R302.1 FBC Energy Conservation 2020 7Th edition 2. Energy Calcs need to be signed by the builder per 107.1 FBC Residential 2020 7th edition
PLUM CANCEL 04/14/2022 04/14/2022
SW1 HOLD 04/14/2022 04/22/2022
Note: Held By: ROBERT GROSS - (386)986-4769 - RGROSS@PALMCOASTGOV.COM See all highlighted items on the Checklist dated 4/22/22 that need to be on the proposed site plan
ZON HOLD 04/14/2022 04/18/2022
Note: Held By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM Garages shall not exceed 50 percent of the total living area of the principal dwelling unit. If it has a garage door it is considered a garage and this addition will exceed the 50 percent allowed. Please provide calculations on floor plan Please provide material and width of driveway on site plan Please provide a termination of easement application will all letters from utility companies releasing the easement All windows and doors facing right of way must have banding. Please provide a landscape plan for addition

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
PLAN REVIEW - REVISION ¤32.50 07/10/2024
PLAN REVIEW - REVISION ¤32.50 05/12/2023
ADMINISTRATIVE RESIDENTIAL ¤30.00 07/01/2022
INSPECTION - RESIDENTIAL ¤275.00 07/01/2022
PLAN REVIEW - RESIDENTIAL ¤78.00 07/01/2022
RECORDING FEE REIMBURSE DOC ¤35.50 07/01/2022
SURCHARGE FS 533.721 ¤3.44 07/01/2022
SURCHARGE - FS 468.631 ¤5.15 07/01/2022
SW ENG - INSPECTION 20 ¤20.00 07/01/2022
SW ENG - REVIEW 20 ¤20.00 07/01/2022
SITE PLAN 30 ¤30.00 07/01/2022
Fees Total Due: ¤0.00 Total Paid: ¤562.09