I want to search for...

Permit #2022041123

Permit Details

Status: COED

Parcel Id: 07-11-31-7028-00640-0050
CONDITIONED SPACE: 1797 sqft
OPENED PORCH (WITH ROOF) : 124 sqft
SCREEN PORCH (SOLID ROOF) : 128 sqft
GARAGE: 587 sqft
Total Square Footage: 2636 sqft
Block: 00640
Subdivision: 2199 - SECTION 28-WYNNFIELD
Job Phone: 407-580-2657
Location Address: 17 POST VIEW DR
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 06/13/2022
NOC: RECORDED
Applicant name: GENE WARREN SLONE
Owner: GANTZ ARNOLD JAMES & INGA MADRID H&W

Address

3300 N W 177 TERR

MIAMI GARDENS, FL 33056

Lot: 0050
Contracted Stated Job Value: ¤400,000.00
Job Description: SINGLE FAMILY HOME
Type: CN

Contractor

FLORIDA GREEN CONSTRUCTION INC.
Status Location Address State License Number Phone
INACTIVE

870 E RETTA STREET

DELEON SPRINGS, FL 32130

CBC1260957 (Exp: 08/31/2026) 407-580-2657

Sub Contractors

JOHN EDWARD GAMBONE
Status Location Address Mailing Address State License Number Phone
ACTIVE

15 HARGROVE LN

PALM COAST, FL 32137

1G

PALM COAST, FL 32137

EC13006037 (Exp: 08/31/2026) 386-586-9144
KERRY DWAIN AYLESWORTH II
Status Location Address Mailing Address State License Number Phone
ACTIVE

2820 LEWIS SPEEDWAY

ST AUGUSTINE, FL 32084

STE B

ST AUGUSTINE, FL 32084

CAC1820713 (Exp: 08/31/2026) 904-342-5709
JONATHAN M PEARSON
Status Location Address State License Number Phone Fax
ACTIVE

209 N FORSYTH ST

BUNNELL, FL 32110

CFC1425941 (Exp: 08/31/2026) 386-597-0944 386-437-4996
ERIC FRANCO
Status Location Address Mailing Address State License Number Phone
INACTIVE

840 DELTONA BLVD

DELTONA, FL 32725

STE F2

DELTONA, FL 32725

CCC1327280 (Exp: 08/31/2026) 386-575-4007

Inspection History

Type Request Date Result Inspector
BLD - BUILDING FINAL 11/02/2023 FINAL APPROVED KSANDOE
Note: 10/30/2023 - PREVIOUS INSPECTION NOTES 1. The bidet need to have a temprature limiting device installed. Water temp is to be limited to 110 degrees. P-408. 2. The one of two required kitchen branch circuits at the kitchen island can serve no other outlets. The island outlets for the counter top is also supplying the built in microwave. NEC 210.52 (B) 2.
BLD - BUILDING FINAL 10/30/2023 Disapproved - NO FEE JWALKER
Note: 1. The bidet need to have a temprature limiting device installed. Water temp is to be limited to 110 degrees. P-408. 2. The one of two required kitchen branch circuits at the kitchen island can serve no other outlets. The island outlets for the counter top is also supplying the built in microwave. NEC 210.52 (B) 2.
U-CROSS CONNECTION 10/12/2023 APPROVED - AS NOTED LFITZGERALD
Note: has potable irrigation with PVB installed
ROW - FINAL APRON (AFTER POUR) 10/12/2023 APPROVED PFLANAGAN
Note: At the time of the inspection all minimum city requirements were met. It is the builders responsibiliy to ensure that nothing changes after this Inspection is approved.
ROW - STORMWATER FINAL 10/12/2023 APPROVED PFLANAGAN
Note: At the time of the inspection all minimum city requirements were met. It is the builders responsibiliy to ensure that nothing changes after this Inspection is approved.
U -UTILITY RESIDENTIAL FINAL 10/12/2023 APPROVED - AS NOTED LFITZGERALD
Note: need stone for pep tank lid-utility informed
ROW FIELD SURVEY /GRADING CERTIFICATION 10/11/2023 APPROVED FSLADISH
Note: 10/11/23 UPON WALKING PROPERTY DRAINAGE WILL WORK AS INDICATED. At the time of the inspection all minimum city requirements were met. It is the builders responsibiliy to ensure that nothing changes after this Inspection is approved. _________________________________________________________________________________________________________________________ WILL NOT ALLOW ME TO DO THIS INSPECTION SAYS CONTRACTOR NOT ACTIVE
ROW- FINAL SURVEY/GRADING CERTIFICATION 10/09/2023 APPROVED PFLANAGAN
Note: At the time of the inspection all minimum city requirements were met. It is the builders responsibiliy to ensure that nothing changes after this Inspection is approved. ----------------------------------------------------------------- 9/26/2023 - PREVIOUS INSPECTION NOTES 1) Sec 300.03 C1c When grading against a developable vacant lot a 'Common Swale' (meaning the drainage conveyance is on the property line) is required. 2) Drainage from the structure is to be a 6 inch (5%) minimum slope for the first 10’. Florida Building Code, Residential, Chapter 4, R401.3 3) Swale Plan #1. The driveway culvert inverts are to be installed within 0.1' (+/-) of the elevations indicated on the swale plan and can not be pitch against the flow of the roadside swale.
ROW- PROJECT STATUS 10/05/2023 APPROVED PFLANAGAN
Note: GRADES OK NEED TO MAKE THE CULVERT IN TOLERANCE
ROW- FINAL SURVEY/GRADING CERTIFICATION 09/26/2023 Disapproved - NO FEE PFLANAGAN
Note: 1) Sec 300.03 C1c When grading against a developable vacant lot a 'Common Swale' (meaning the drainage conveyance is on the property line) is required. 2) Drainage from the structure is to be a 6 inch (5%) minimum slope for the first 10’. Florida Building Code, Residential, Chapter 4, R401.3 3) Swale Plan #1. The driveway culvert inverts are to be installed within 0.1' (+/-) of the elevations indicated on the swale plan and can not be pitch against the flow of the roadside swale.
ELECTRIC - EARLY POWER 09/26/2023 APPROVED - AS NOTED KSANDOE
Note: Emailed FPL @ 0951. Release Power 9/22/2023 - PREVIOUS INSPECTION NOTES 9/22/23: * Main feeds cannot be landed at Meter Panel for underground feed prior to approved Early Power Inspection. Inspector Notes from Inspection 2200 Emailed FPL @ 1156. Release Power Inspector Notes from Inspection 2170 THIS IS A REINSPECTION Temp pole needs to be grounded. NEC 2017 250.52 7/8/22 Emailed FPL at 8:41 am
ELECTRIC - EARLY POWER 09/22/2023 Disapproved - NO FEE RSIMS
Note: 9/22/23: * Main feeds cannot be landed at Meter Panel for underground feed prior to approved Early Power Inspection. Inspector Notes from Inspection 2200 Emailed FPL @ 1156. Release Power Inspector Notes from Inspection 2170 THIS IS A REINSPECTION Temp pole needs to be grounded. NEC 2017 250.52 7/8/22 Emailed FPL at 8:41 am
ROW- PRE-APRON (PRE-POUR) 08/14/2023 APPROVED - AS NOTED FSLADISH
Note: 08/14/23 you need to remove all dirt from the culvert pipe before pouring. you need to remove all concrete, concrete chips and any concrete chunks against garage slab before pouring. Pipe is good. Approving as noted, it is builders responsibility to make sure these are done. AT THE TIME OF THE INSPECTION CULVERT PIPE IS GOOD IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD DOUBLE CHECK CULVERT ELEVATIONS BEFORE POURING. MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL At the time of the inspection all minimum city requirements were met. It is the builders responsibiliy to ensure that nothing changes after this Inspection is approved. This includes but is not limited to, the Culvert Pipe Elevation from the time of the inspection approval to the concrete pour. PHOTOS FOR REFERENCE. 8/11/2023 - PREVIOUS INSPECTION NOTES 08/11/23 THIS IS NOT READY FOR POURING. THERE IS TO MUCH WATER IN THE POURING AREA. NEED TO PUMP ALL WATER OUT. THE POUR AREA IS TOO SOFT. THE CULVERT ENDS ARE WASHED IN AND FULL OF DIRT AND SEDIMENT, CANNOT CHECK PIPE. WASHED OUT BEHIND ROW NEEDS TO BE FILLED BACK IN AND COMPACTED, PLEASE SEE PHOTOS FOR REFERENCE. _______________________________________________________________________________________________________________________ SITE NEEDS TO BE PREPPED TO POUR AT THE TIME OF THE INSPECTION 7/31/2023 - PREVIOUS INSPECTION NOTES THIS IS NOT READY FOR INSPECTION THERE IS TO MUCH WATER IN THE POURING AREA. NEED TO PUMP ALL WATER OUT. SITE NEEDS TO BE PREPPED TO POUR AT THE TIME OF THE INSPECTION ANY LESS IT WILL FAIL.
ROW- PRE-APRON (PRE-POUR) 08/11/2023 Disapproved -FEE REQUIRED FSLADISH
Note: 08/11/23 THIS IS NOT READY FOR POURING. THERE IS TO MUCH WATER IN THE POURING AREA. NEED TO PUMP ALL WATER OUT. THE POUR AREA IS TOO SOFT. THE CULVERT ENDS ARE WASHED IN AND FULL OF DIRT AND SEDIMENT, CANNOT CHECK PIPE. WASHED OUT BEHIND ROW NEEDS TO BE FILLED BACK IN AND COMPACTED, PLEASE SEE PHOTOS FOR REFERENCE. _______________________________________________________________________________________________________________________ SITE NEEDS TO BE PREPPED TO POUR AT THE TIME OF THE INSPECTION 7/31/2023 - PREVIOUS INSPECTION NOTES THIS IS NOT READY FOR INSPECTION THERE IS TO MUCH WATER IN THE POURING AREA. NEED TO PUMP ALL WATER OUT. SITE NEEDS TO BE PREPPED TO POUR AT THE TIME OF THE INSPECTION ANY LESS IT WILL FAIL.
ROW- PRE-APRON (PRE-POUR) 07/31/2023 Disapproved -FEE REQUIRED PFLANAGAN
Note: THIS IS NOT READY FOR INSPECTION THERE IS TO MUCH WATER IN THE POURING AREA. NEED TO PUMP ALL WATER OUT. SITE NEEDS TO BE PREPPED TO POUR AT THE TIME OF THE INSPECTION ANY LESS IT WILL FAIL.
U - SEWER TIE IN 06/05/2023 APPROVED MGIBSON
GRAVITY SEWER TEST 06/05/2023 APPROVED MGIBSON
Note: Inspector Notes from Inspection 2060 NEED TO CORRECT PLUMBING CONTRACTOR FOR WARRANTY PURPOSE
ELECTRIC-TUG 05/05/2023 APPROVED - AS NOTED KSANDOE
Note: Emailed FPL @ 1156. Release Power Inspector Notes from Inspection 2170 THIS IS A REINSPECTION Temp pole needs to be grounded. NEC 2017 250.52 7/8/22 Emailed FPL at 8:41 am
PEP TANK INSTALLATION REQUEST 05/03/2023 APPROVED CSTONE
LATH/BRICK/ WATER BARRIER 04/24/2023 APPROVED KSANDOE
INSULATION 04/10/2023 APPROVED KSANDOE
ALL ROUGH 04/04/2023 APPROVED KSANDOE
ROOF VALLEY & METAL 01/13/2023 APPROVED KSANDOE
WALL SHEATHING 12/22/2022 APPROVED KSANDOE
TIE BEAM / LINTEL 12/20/2022 CANCELLED BY APPLICANT WEB
ROOF SHEATHING / BRACES/TIES/DOWN CELL 12/20/2022 APPROVED KSANDOE
Note: 12/16/2022 - PREVIOUS INSPECTION NOTES Multiple trusses missing nailing on straps. Check all Reschedule and Meet inspector on site to discuss garage bearing wall
ROOF SHEATHING / BRACES/TIES/DOWN CELL 12/16/2022 Disapproved - NO FEE KSANDOE
Note: Multiple trusses missing nailing on straps. Check all Reschedule and Meet inspector on site to discuss garage bearing wall
TIE BEAM / LINTEL 10/05/2022 APPROVED KSANDOE
Note: 10/4/2022 - PREVIOUS INSPECTION NOTES 10/2/2022 12:03:12 PM- PREVIOUS INSPECTION NOTES Inspections requested for October 3rd and been rescheduled to October 4th. The Building Inspectors are working with the Utility Department pumping PEP tanks from homes that are currently without power. 9/26/2022 - PREVIOUS INSPECTION NOTES Not ready for inspection 10/4/22 Per sheet 6 Horizontal rebar #4 should be run 16" up from bottom of wall. Unable to verify as is. Contractor reschedule inspection and meet with inspector on site to provide visual verification.
TIE BEAM / LINTEL 10/04/2022 Disapproved - NO FEE KSANDOE
Note: 10/2/2022 12:03:12 PM- PREVIOUS INSPECTION NOTES Inspections requested for October 3rd and been rescheduled to October 4th. The Building Inspectors are working with the Utility Department pumping PEP tanks from homes that are currently without power. 9/26/2022 - PREVIOUS INSPECTION NOTES Not ready for inspection 10/4/22 Per sheet 6 Horizontal rebar #4 should be run 16" up from bottom of wall. Unable to verify as is. Contractor reschedule inspection and meet with inspector on site to provide visual verification.
TIE BEAM / LINTEL 10/03/2022 CANCELLED BY APPLICANT BBEMBRY
Note: Inspections requested for October 3rd and been rescheduled to October 4th. The Building Inspectors are working with the Utility Department pumping PEP tanks from homes that are currently without power. 9/26/2022 - PREVIOUS INSPECTION NOTES Not ready for inspection
TIE BEAM / LINTEL 09/26/2022 Disapproved - NO FEE KSANDOE
Note: Not ready for inspection
FOUND SURVEY APPROVED (OFFICE) 09/15/2022 APPROVED TBAKER
MONOLITHIC SLAB 08/16/2022 APPROVED LMILLER
PLUMBING 1ST ROUGH UNDERGROUND 08/01/2022 APPROVED - AS NOTED MGIBSON
Note: NEED TO CORRECT PLUMBING CONTRACTOR FOR WARRANTY PURPOSE
ELECTRIC TEMP POLE 07/08/2022 APPROVED - AS NOTED JMUNSON
Note: THIS IS A REINSPECTION Temp pole needs to be grounded. NEC 2017 250.52 7/8/22 Emailed FPL at 8:41 am
ELECTRIC TEMP POLE 07/06/2022 Disapproved - NO FEE JMUNSON
Note: Temp pole needs to be grounded. NEC 2017 250.52
WATER METER INSTALLATION REQUEST 06/17/2022 APPROVED CSTONE

Review History

Department Status Date In Date Out
MECH COMPLETE 10/26/2023 10/27/2023
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
MECH HOLD 10/25/2023 10/26/2023
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Provide Updated Energy calcs. Not altered ones.
ENGIN1 COMPLETE 07/21/2023 07/21/2023
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
SW1 COMPLETE 07/21/2023 07/21/2023
Note: Released By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM
ZON COMPLETE 07/21/2023 07/21/2023
Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM
ENGIN1 COMPLETE 06/27/2023 06/27/2023
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
SW1 COMPLETE 06/27/2023 07/05/2023
Note: Released By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM
ZON COMPLETE 06/27/2023 06/27/2023
Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM
ENGIN1 COMPLETE 09/15/2022 09/15/2022
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
ZON COMPLETE 09/15/2022 09/15/2022
Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM
ELEC COMPLETE 05/25/2022 05/25/2022
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
PLUM CANCEL 05/25/2022 05/31/2022
BLD COMPLETE 04/21/2022 04/21/2022
Note: Released By: FRED REODICA - (386)986-4734 - FREODICA@PALMCOASTGOV.COM
CUSVC COMPLETE 04/21/2022 04/25/2022
Note: Released By: ALYSSA ROSCOE - -
ELEC HOLD 04/21/2022 04/22/2022
Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. Need outlets under switches in bed 2 and 3. NEC 2017 210.52 2. Submit manufacture specs and riser diagram for generator.
ENGIN1 COMPLETE 04/21/2022 04/21/2022
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
LOCATE COMPLETE 04/21/2022 04/26/2022
Note: Released By: CANDACE STONE - - CSTONE@PALMCOASTGOV.COM
MECH COMPLETE 04/21/2022 04/22/2022
Note: Released By: CHRIS PISCITELLI - (386)986-3782 - CPISCITELLI@PALMCOASTGOV.COM
SW1 COMPLETE 04/21/2022 04/28/2022
Note: Released By: PARREN FLANAGAN - - PFLANAGAN@PALMCOASTGOV.COM
ZON COMPLETE 04/21/2022 04/22/2022
Note: Released By: CINDY CHIRI-GONCALVES - - CGONCALVES@PALMCOASTGOV.COM
SWALE COMPLETE 04/21/2022 06/22/2022
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
PLAN REVIEW - REVISION ¤32.50 11/02/2023
SW ENG REINSPECTION 20 ¤20.00 10/25/2023
SW ENG REINSPECTION 30 ¤30.00 10/25/2023
SW ENG REINSPECTION 30 ¤30.00 10/25/2023
SW ENG - REVIEW 20 ¤20.00 06/13/2022
SW ENG RES REVIEW 200 ¤200.00 06/13/2022
3% TRANS IMPACT FEE CREDIT (¤52.92) 06/13/2022
SEWER CREDIT (¤650.00) 06/13/2022
SEWER INSPECTION ¤25.00 06/13/2022
SEWER CAPITAL FACILITY ¤4,939.76 06/13/2022
WATER CAPITAL FACILITY FEE ¤3,626.50 06/13/2022
SITE PLAN 30 ¤30.00 06/13/2022
CONNECTION FEES ¤1,077.88 06/13/2022
3% FIRE IMPACT FEE CREDIT (¤11.66) 06/13/2022
IMPACT FEE FIRE ¤388.65 06/13/2022
IMPACT FEE PARKS ¤1,455.13 06/13/2022
IMPACT FEE SCHOOL ¤3,600.00 06/13/2022
IMPACT FEE TRANSPORTATION ¤1,764.00 06/13/2022
WATER -IRRIGATION INSPECTION ¤25.00 06/13/2022
3% PARKS IMPACT FEE CREDIT (¤43.65) 06/13/2022
SURCHARGE FS 533.721 ¤11.90 06/13/2022
SURCHARGE - FS 468.631 ¤17.85 06/13/2022
SW ENG - FOUNDATION SURVEY ¤20.00 06/13/2022
SW ENG INSPECTION 80 ¤80.00 06/13/2022
SW ENG PRE APRON ¤30.00 06/13/2022
WATER- TURN ON ¤25.00 06/13/2022
ADMINISTRATIVE RESIDENTIAL ¤30.00 06/13/2022
INSPECTION - RESIDENTIAL ¤1,100.00 06/13/2022
PLAN REVIEW - RESIDENTIAL ¤312.00 06/13/2022
Fees Total Due: ¤0.00 Total Paid: ¤18,132.94