I want to search for...

Permit #2022041272

Permit Details

Status: COED

Parcel Id: 07-11-31-7004-00080-0030
Block: 00080
Subdivision: 2203 - SECTION 4-COUNTRY CLUB COVE
Job Phone: 904-759-6435
Location Address: 9 CLARIDGE CT N
Type: RF - REROOF
Issue Date: 04/25/2022
NOC: RECORDED
Applicant name: DAVID GLENN ENGLAND
Owner: DANYUS MICHAEL & PATRICIA M

Address

9 CLARIDGE COURT NORTH

PALM COAST, FL 32137

Lot: 0030
Contracted Stated Job Value: ¤8,000.00
Job Description: re-roof
Type: CN

Contractor

ENGLAND CLASSIC ROOFING INC
Status Location Address State License Number Phone
ACTIVE

PO BOX 840006

ST AUGUSTINE, FL 32080

CCC1330631 (Exp: 08/31/2026) 904-759-6435

Inspection History

Type Request Date Result Inspector
ROOF FINAL 06/06/2022 FINAL APPROVED MKRASKI
ROOF IN PROGRESS- MIDROOF 06/02/2022 APPROVED LMILLER
Note: THIS IS A REINSPECTION THIS IS A REINSPECTION not ready still stripping 6-1-22 1. Revision needed for type of shingles and underlayment. (gaf was used for both) 2. underlayment was not lapped properly to achieve double coverage per manufacturer specs. (all shingles will need to be removed and place new underlayment per code and manufacutrer specs). (do not place any shingled in the areas where shigngle were removed prior to next midroof inspection). 3. underlayment overlaps need to be nailed 6 inches OC max, and 12 inch max OC in the field (recall midroof when shingles have been removed, new underlayment applied per specs, and have up to 25 percent shingles attached. 6-2-22 notes above resolved
ROOF IN PROGRESS- MIDROOF 06/01/2022 Disapproved -FEE REQUIRED LMILLER
Note: THIS IS A REINSPECTION not ready still stripping 6-1-22 1. Revision needed for type of shingles and underlayment. (gaf was used for both) 2. underlayment was not lapped properly to achieve double coverage per manufacturer specs. (all shingles will need to be removed and place new underlayment per code and manufacutrer specs). (do not place any shingled in the areas where shigngle were removed prior to next midroof inspection). 3. underlayment overlaps need to be nailed 6 inches OC max, and 12 inch max OC in the field (recall midroof when shingles have been removed, new underlayment applied per specs, and have up to 25 percent shingles attached.
ROOF AFFIDAVIT 05/31/2022 APPROVED STHOMAS
ROOF IN PROGRESS- MIDROOF 05/31/2022 Disapproved - NO FEE LMILLER
Note: not ready still stripping

Review History

Department Status Date In Date Out
BADMIN INFORMATION 06/02/2022 06/02/2022
Note: Marked INFORMATION By: MARGA DEFREITAS - - MDEFREITAS@PALMCOASTGOV.COM IF YOU ARE CHANGING THE PRODUCT APPFOVAL NUMBERS YOU WILL NEED TO SUBMIT A NEW ROOFING WORKSHEET
BLD COMPLETE 06/02/2022 06/02/2022
Note: Released By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
PLAN REVIEW - REVISION ¤32.50 06/02/2022
REINSPECTION RESIDENTIAL ¤40.00 06/02/2022
SURCHARGE FS 533.721 ¤2.00 04/25/2022
SURCHARGE - FS 468.631 ¤2.00 04/25/2022
ADMINISTRATIVE RESIDENTIAL ¤30.00 04/25/2022
INSPECTION - RESIDENTIAL ¤60.00 04/25/2022
Fees Total Due: ¤0.00 Total Paid: ¤166.50