Permit #2022041359
Permit Details
Status: FINAL
| Parcel Id: 07-11-31-7035-00930-0190 |
| CONDITIONED SPACE: 2474 sqft |
| GARAGE: 520 sqft |
| OPENED PORCH (WITH ROOF) : 300 sqft |
| OPENED PORCH (WITH ROOF) : 60 sqft |
| Total Square Footage: 3354 sqft |
| Block: 00930 |
| Subdivision: 2172 - SECTION 35-BELLE TERRE |
| Job Phone: 386-931-6577 |
| Location Address: 28 BUFFALO BILL DR |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 05/16/2022 |
| NOC: RECORDED |
| Applicant name: LUIS JORGE MEDEIROS |
| Owner: FERRAREZI THAIS LIMA & LAIS CORREIA PEREIRA |
|
Address 15742 SE 96TH COURT SUMMERFIELD, FL 34491 |
| Lot: 0190 |
| Contracted Stated Job Value: ¤300,000.00 |
| Job Description: SINGLE FAMILY RESIDENCE |
| Type: CN |
Contractor
A PLUS HOME IMPROVEMENTS LLC
| Status | Location Address | State License Number | Phone |
| ACTIVE |
306 S RAILROAD ST BUNNELL, FL 32110 |
CRC1327024 (Exp: 08/31/2026) | 386-263-2167 |
Sub Contractors
FERNANDO M FARIA
| Status | Location Address | State License Number | Phone |
| ACTIVE |
23 FREELAND LANE PALM COAST, FL 32137 |
RF11067823 (Exp: 08/31/2027) | 386-569-4336 |
CHRISTIAN GALARZA
| Status | Location Address | State License Number | Phone |
| INACTIVE |
514 ELKHORN FERN LANE DELAND, FL 32720 |
CCC1332550 (Exp: 08/31/2024) | 386-734-1955 |
JOSEPH MOUAG
| Status | Location Address | State License Number | Phone |
| ACTIVE |
842 BANBURY DRIVE PORT ORANGE, FL 32129 |
EC13006957 (Exp: 08/31/2026) | 386-547-3722 |
GARY LLOYD SHEFFIELD
| Status | Location Address | State License Number | Phone |
| ACTIVE |
1815 US HWY 1 ORMOND BEACH, FL 32174 |
CAC1821959 (Exp: 08/31/2026) | 386-238-9117 |
GLEN WILLIAM KEHLE
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
P. O. Box 353511 BUNNELL, FL 32110 |
CFC057241 (Exp: 08/31/2026) | (386) 447-4249 | (386) 437-8488 |
Inspection History
| Type | Request Date | Result | Inspector |
| BLD - BUILDING FINAL | 04/23/2026 | FINAL APPROVED | HCAMACHO |
| Note: 1/7/2026 - PREVIOUS INSPECTION NOTES 1/7/26 1. No hot water FBCR P2722.2 2. Electrical box above outdoor kithchen needs to be outdoor rated NEC 406.9 3. Outdoor kitchen has visible water underneath and needs to be sealed up properly 4. Tree branches are visibly on roof and lessens the life of the shingles. Needs to be cut back 5. Dryer vent needs to be capped/sealed when not in use FBC-M1502.4.7 6. Smoke alarm in mater BR chirping and nees to be replaced FBCR 314 & 315 7. Seal all wall and ceiling penetrations in garage FBC 402.5.1.1 8. Seal up ceiling penetrations around AH and intake air FBCR 302.11 9. Fridge required to be GFCi or Arc/fault protected NEC 210.12 10. Pep tank required to be GFCi protected NEC 422.5 11. Breaker #32 not labaled in panel NEC 408.4 12. Kitchen island outlets do not meet code requirements since the overhang is more than 6". Will need to add pop up outlets or side mounted outlets NEC-210.52(C)(3)(3) 13. AC needs to be 3" above finished grade FBCR M1305.1.4.1 / FBCR 1307.1/ NEC 110.26 | |||
| BLD - BUILDING FINAL | 01/07/2026 | Disapproved -FEE REQUIRED | MCONTRYMAN |
| Note: 1/7/26 1. No hot water FBCR P2722.2 2. Electrical box above outdoor kithchen needs to be outdoor rated NEC 406.9 3. Outdoor kitchen has visible water underneath and needs to be sealed up properly 4. Tree branches are visibly on roof and lessens the life of the shingles. Needs to be cut back 5. Dryer vent needs to be capped/sealed when not in use FBC-M1502.4.7 6. Smoke alarm in mater BR chirping and nees to be replaced FBCR 314 & 315 7. Seal all wall and ceiling penetrations in garage FBC 402.5.1.1 8. Seal up ceiling penetrations around AH and intake air FBCR 302.11 9. Fridge required to be GFCi or Arc/fault protected NEC 210.12 10. Pep tank required to be GFCi protected NEC 422.5 11. Breaker #32 not labaled in panel NEC 408.4 12. Kitchen island outlets do not meet code requirements since the overhang is more than 6". Will need to add pop up outlets or side mounted outlets NEC-210.52(C)(3)(3) 13. AC needs to be 3" above finished grade FBCR M1305.1.4.1 / FBCR 1307.1/ NEC 110.26 | |||
| U -UTILITY RESIDENTIAL FINAL | 01/07/2026 | FINAL APPROVED | BWRIGHT |
| Note: New inspection due to canceled inspection New inspection due to canceled inspection Inspector Notes from Inspection 9035 potablevirr with PVB-no cross connection | |||
| ROW- PROJECT STATUS | 12/11/2025 | Status Check | PFLANAGAN |
| Note: Please make sure the drainage is working on this site without impacting the neighboring house in the back. Drainage will not impact the adjacent lot to the rear. | |||
| BLD - BUILDING FINAL | 11/07/2025 | CANCELLED BY APPLICANT | WEB |
| U -UTILITY RESIDENTIAL FINAL | 11/07/2025 | CANCELLED BY APPLICANT | WEB |
| Note: New inspection due to canceled inspection Inspector Notes from Inspection 9035 potablevirr with PVB-no cross connection | |||
| U -UTILITY RESIDENTIAL FINAL | 11/06/2025 | CANCELLED BY APPLICANT | WEB |
| Note: Inspector Notes from Inspection 9035 potablevirr with PVB-no cross connection | |||
| BLD - BUILDING FINAL | 11/06/2025 | CANCELLED BY APPLICANT | WEB |
| ROW - FINAL APRON (AFTER POUR) | 11/05/2025 | APPROVED | TPOLACEK |
| Note: AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED | |||
| ROW FIELD SURVEY /GRADING CERTIFICATION | 11/05/2025 | APPROVED | TPOLACEK |
| Note: AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED 10/27/2025 - PREVIOUS INSPECTION NOTES ** 10/27/25 CANCELLED ON SITE BY NANCY FROM A+ HOMES ___________________________________________________________________________________________________________________ 9/18/2025 - PREVIOUS INSPECTION NOTES ** 09/18/25 AS NOTED IN PREVIOUS FIELD SURVEY ON 07/03/25 THAT WAS DISAPPROVED NEED TO RAISE THE ELEVATION OF ROADSIDE SWALE ON RIGHT SIDE AS IT IS STILL HOLDING WATER NEED TO REMOVE HIGH SPOT AT THE PROPERTY LINE SO WATER WILL FLOW FROM LEFT TO RIGHT ** SEE NOTES BELOW ____________________________________________________________________________________________________________________ 7/3/2025 - PREVIOUS INSPECTION NOTES THE FRONT ROADSIDE SWALE IS HOLDING WATER AT THIS TIME. NEED TO RAISE SWALE SO WATER WILL HOLD IN THE CULVERT AND NOTE IN THE ROADSIDE SWALE IN THE FRONT YARD. IF YOU NEED INSTRUCTIONS ON HOW TO GRADE SWALE PROPERLY PLEASE SEE DRAWING IN TEC. MANUAL LABELED TYIPCAL NEW HOME SWALE DESIGN ------------------------------------------------------------------------------------------------------- THE DRAINAGE OF THIS LOT WILL NOT IMPACT ANY ADJACENT LOT SURROUND THIS LOT AT THIS TIME. ------------------------------------------------------------------------------------------------------- NOT TO INSPECTOR: This was an Infill visit Gabe/Ed 9/17/24 about water coming under the fence in the rear from the new build behind her. Please be sure builder has graded to ensure no water flows under the fence to house 20 Buffalo Grove Pl. Spoke to resident about this note to inspector on 11/18/24. Final Survey has already been dissapproved at this point. | |||
| ROW - STORMWATER FINAL | 11/05/2025 | APPROVED | TPOLACEK |
| Note: AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED | |||
| ROW FIELD SURVEY /GRADING CERTIFICATION | 10/27/2025 | CANCELLED BY APPLICANT | EMADISON |
| Note: ** 10/27/25 CANCELLED ON SITE BY NANCY FROM A+ HOMES ___________________________________________________________________________________________________________________ 9/18/2025 - PREVIOUS INSPECTION NOTES ** 09/18/25 AS NOTED IN PREVIOUS FIELD SURVEY ON 07/03/25 THAT WAS DISAPPROVED NEED TO RAISE THE ELEVATION OF ROADSIDE SWALE ON RIGHT SIDE AS IT IS STILL HOLDING WATER NEED TO REMOVE HIGH SPOT AT THE PROPERTY LINE SO WATER WILL FLOW FROM LEFT TO RIGHT ** SEE NOTES BELOW ____________________________________________________________________________________________________________________ 7/3/2025 - PREVIOUS INSPECTION NOTES THE FRONT ROADSIDE SWALE IS HOLDING WATER AT THIS TIME. NEED TO RAISE SWALE SO WATER WILL HOLD IN THE CULVERT AND NOTE IN THE ROADSIDE SWALE IN THE FRONT YARD. IF YOU NEED INSTRUCTIONS ON HOW TO GRADE SWALE PROPERLY PLEASE SEE DRAWING IN TEC. MANUAL LABELED TYIPCAL NEW HOME SWALE DESIGN ------------------------------------------------------------------------------------------------------- THE DRAINAGE OF THIS LOT WILL NOT IMPACT ANY ADJACENT LOT SURROUND THIS LOT AT THIS TIME. ------------------------------------------------------------------------------------------------------- NOT TO INSPECTOR: This was an Infill visit Gabe/Ed 9/17/24 about water coming under the fence in the rear from the new build behind her. Please be sure builder has graded to ensure no water flows under the fence to house 20 Buffalo Grove Pl. Spoke to resident about this note to inspector on 11/18/24. Final Survey has already been dissapproved at this point. | |||
| ROW FIELD SURVEY /GRADING CERTIFICATION | 09/18/2025 | Disapproved - NO FEE | EMADISON |
| Note: ** 09/18/25 AS NOTED IN PREVIOUS FIELD SURVEY ON 07/03/25 THAT WAS DISAPPROVED NEED TO RAISE THE ELEVATION OF ROADSIDE SWALE ON RIGHT SIDE AS IT IS STILL HOLDING WATER NEED TO REMOVE HIGH SPOT AT THE PROPERTY LINE SO WATER WILL FLOW FROM LEFT TO RIGHT ** SEE NOTES BELOW ____________________________________________________________________________________________________________________ 7/3/2025 - PREVIOUS INSPECTION NOTES THE FRONT ROADSIDE SWALE IS HOLDING WATER AT THIS TIME. NEED TO RAISE SWALE SO WATER WILL HOLD IN THE CULVERT AND NOTE IN THE ROADSIDE SWALE IN THE FRONT YARD. IF YOU NEED INSTRUCTIONS ON HOW TO GRADE SWALE PROPERLY PLEASE SEE DRAWING IN TEC. MANUAL LABELED TYIPCAL NEW HOME SWALE DESIGN ------------------------------------------------------------------------------------------------------- THE DRAINAGE OF THIS LOT WILL NOT IMPACT ANY ADJACENT LOT SURROUND THIS LOT AT THIS TIME. ------------------------------------------------------------------------------------------------------- NOT TO INSPECTOR: This was an Infill visit Gabe/Ed 9/17/24 about water coming under the fence in the rear from the new build behind her. Please be sure builder has graded to ensure no water flows under the fence to house 20 Buffalo Grove Pl. Spoke to resident about this note to inspector on 11/18/24. Final Survey has already been dissapproved at this point. | |||
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 09/18/2025 | APPROVED | EMADISON |
| Note: ** 09/18/25 FINAL SURVEY WAS PREVIOUSLY APPROVED ON 07/03/25 BY P. FLANAGAN | |||
| ROW FIELD SURVEY /GRADING CERTIFICATION | 07/03/2025 | Disapproved - NO FEE | PFLANAGAN |
| Note: THE FRONT ROADSIDE SWALE IS HOLDING WATER AT THIS TIME. NEED TO RAISE SWALE SO WATER WILL HOLD IN THE CULVERT AND NOTE IN THE ROADSIDE SWALE IN THE FRONT YARD. IF YOU NEED INSTRUCTIONS ON HOW TO GRADE SWALE PROPERLY PLEASE SEE DRAWING IN TEC. MANUAL LABELED TYIPCAL NEW HOME SWALE DESIGN ------------------------------------------------------------------------------------------------------- THE DRAINAGE OF THIS LOT WILL NOT IMPACT ANY ADJACENT LOT SURROUND THIS LOT AT THIS TIME. ------------------------------------------------------------------------------------------------------- NOT TO INSPECTOR: This was an Infill visit Gabe/Ed 9/17/24 about water coming under the fence in the rear from the new build behind her. Please be sure builder has graded to ensure no water flows under the fence to house 20 Buffalo Grove Pl. Spoke to resident about this note to inspector on 11/18/24. Final Survey has already been dissapproved at this point. | |||
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 07/03/2025 | APPROVED - AS NOTED | PFLANAGAN |
| Note: FINAL SURVEY STATES THAT THE DRAINAGE OF THIS LOT WILL NOT IMPACT ANY ADJACENT LOTS SURROUND THIS ONE. PASSING THIS AS NOTED BECAUSE OF THE INFILL LOT BEHIND THIS LOT. ------------------------------------------------------------------- 6/27/2025 - PREVIOUS INSPECTION NOTES 6/27/25=YOU NEED TO GRADE THE SWALE, AS IT IS PITCHING IN THE WRONG DIRECTION. ADDITIONALLY, THE CULVERT PIPE NEEDS TO BE CLEANED, AND THE ELEVATION SHOULD BE RECHECKED. WATER IN THE SWALE IS MOVING FROM LEFT TO RIGHT. i did check the elevation and the pipe is not to bad note to the inspector. gbertola 6/5/2025 - PREVIOUS INSPECTION NOTES THE SURVEYORS DID NOT CATURE THE DRAINAGE FEATURES ON THIS LOT CORRECTLY. ------------------------------------------------------------------------------------ 12/3/2024 - PREVIOUS INSPECTION NOTES ** 12/03/24 CULVERT IS OUT OF TOLERANCE CULVERT ELEVATION IN ACCORDANCE WITH TH SWALE PLAN IS (30.50) YOUR FINAL SURVEY IS SHOWING A (30.35 LEFT SIDE) (30.25 RIGHT SIDE) ** "The driveway culvert(s) must be set within the range established by the Swale Plan. The culvert cannot be sloped against the drainage flow nor shall it be sloped more than 0.10 feet in the direction of the drainage flow.Sec.300.01 C3" ___________________________________________________________________________________________________________________ | |||
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 06/27/2025 | Disapproved -FEE REQUIRED | GBERTOLA |
| Note: 6/27/25=YOU NEED TO GRADE THE SWALE, AS IT IS PITCHING IN THE WRONG DIRECTION. ADDITIONALLY, THE CULVERT PIPE NEEDS TO BE CLEANED, AND THE ELEVATION SHOULD BE RECHECKED. WATER IN THE SWALE IS MOVING FROM LEFT TO RIGHT. i did check the elevation and the pipe is not to bad note to the inspector. gbertola 6/5/2025 - PREVIOUS INSPECTION NOTES THE SURVEYORS DID NOT CATURE THE DRAINAGE FEATURES ON THIS LOT CORRECTLY. ------------------------------------------------------------------------------------ 12/3/2024 - PREVIOUS INSPECTION NOTES ** 12/03/24 CULVERT IS OUT OF TOLERANCE CULVERT ELEVATION IN ACCORDANCE WITH TH SWALE PLAN IS (30.50) YOUR FINAL SURVEY IS SHOWING A (30.35 LEFT SIDE) (30.25 RIGHT SIDE) ** "The driveway culvert(s) must be set within the range established by the Swale Plan. The culvert cannot be sloped against the drainage flow nor shall it be sloped more than 0.10 feet in the direction of the drainage flow.Sec.300.01 C3" ___________________________________________________________________________________________________________________ | |||
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 06/05/2025 | Disapproved -FEE REQUIRED | PFLANAGAN |
| Note: THE SURVEYORS DID NOT CATURE THE DRAINAGE FEATURES ON THIS LOT CORRECTLY. ------------------------------------------------------------------------------------ 12/3/2024 - PREVIOUS INSPECTION NOTES ** 12/03/24 CULVERT IS OUT OF TOLERANCE CULVERT ELEVATION IN ACCORDANCE WITH TH SWALE PLAN IS (30.50) YOUR FINAL SURVEY IS SHOWING A (30.35 LEFT SIDE) (30.25 RIGHT SIDE) ** "The driveway culvert(s) must be set within the range established by the Swale Plan. The culvert cannot be sloped against the drainage flow nor shall it be sloped more than 0.10 feet in the direction of the drainage flow.Sec.300.01 C3" ___________________________________________________________________________________________________________________ | |||
| U-CROSS CONNECTION | 02/26/2025 | APPROVED - AS NOTED | LFITZGERALD |
| Note: potablevirr with PVB-no cross connection | |||
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 12/03/2024 | Disapproved -FEE REQUIRED | EMADISON |
| Note: ** 12/03/24 CULVERT IS OUT OF TOLERANCE CULVERT ELEVATION IN ACCORDANCE WITH TH SWALE PLAN IS (30.50) YOUR FINAL SURVEY IS SHOWING A (30.35 LEFT SIDE) (30.25 RIGHT SIDE) ** "The driveway culvert(s) must be set within the range established by the Swale Plan. The culvert cannot be sloped against the drainage flow nor shall it be sloped more than 0.10 feet in the direction of the drainage flow.Sec.300.01 C3" ___________________________________________________________________________________________________________________ | |||
| FINAL SURVEY (OFFICE USE ONLY) | 09/17/2024 | Disapproved - NO FEE | EMADISON |
| Note: ** 09/17/24 CULVERT IS OUT OF TOLERANCE CULVERT ELEVATION IN ACCORDANCE WITH TH SWALE PLAN IS (30.50) YOUR FINAL SURVEY IS SHOWING A (30.35 LEFT SIDE) (30.25 RIGHT SIDE) ** "The driveway culvert(s) must be set within the range established by the Swale Plan. The culvert cannot be sloped against the drainage flow nor shall it be sloped more than 0.10 feet in the direction of the drainage flow.Sec.300.01 C3" | |||
| ELECTRIC - EARLY POWER | 09/13/2024 | APPROVED - AS NOTED | JSTEWART |
| Note: *** NOTES ADDED BY JSTEWART 9/13/2024 9:21:50 AM *** Authorize release of email to FPL | |||
| GRAVITY SEWER TEST | 07/10/2024 | APPROVED | MGIBSON |
| Note: 6/21/2024 - PREVIOUS INSPECTION NOTES Inspector Notes from Inspection 2060 NEED PORTABLE RESTROOM BY NEXT INSPECTION SHERRIF DEPARTMENT SERVING WARRANT WITH SWATT TEAM | |||
| U - SEWER TIE IN | 07/10/2024 | APPROVED | MGIBSON |
| Note: 6/21/2024 - PREVIOUS INSPECTION NOTES Inspector Notes from Inspection 2060 NEED PORTABLE RESTROOM BY NEXT INSPECTION SEE GRAVITY SEWER NOTE | |||
| U - SEWER TIE IN | 06/21/2024 | Disapproved - NO FEE | MGIBSON |
| Note: Inspector Notes from Inspection 2060 NEED PORTABLE RESTROOM BY NEXT INSPECTION SEE GRAVITY SEWER NOTE | |||
| GRAVITY SEWER TEST | 06/21/2024 | Disapproved - NO FEE | MGIBSON |
| Note: Inspector Notes from Inspection 2060 NEED PORTABLE RESTROOM BY NEXT INSPECTION SHERRIF DEPARTMENT SERVING WARRANT WITH SWATT TEAM | |||
| ROW- PRE-APRON (PRE-POUR) | 06/13/2024 | APPROVED - AS NOTED | EMADISON |
| Note: ** 06/13/24 READY TO POUR ** At the time of the inspection all minimum city requirements were met. It is the builders responsibility to ensure that nothing changes after this Inspection is approved. This includes but is not limited to, the Culvert Pipe Elevation from the time of the inspection approval to the concrete pour. **MAKE SURE THERE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL ________________________________________________________________________________________________________________ 6/11/2024 - PREVIOUS INSPECTION NOTES ** 06/11/24 THERE NEEDS TO BE A MINIMUM OF 4 INCHES OF CONCRETE IN THE DRIVEWAY ABOVE THE ROW SEE STRINGLINES LEFT IN PLACE ** NEED TO EITHER EXTEND FORM BOARDS TO GROUND OR BACK FILL AROUND FORMS TO CONTAIN THE CONCRETE WITHIN THE POUR AREA ___________________________________________________________________________________________________________________ 6/6/2024 - PREVIOUS INSPECTION NOTES ** 06/06/24 CANCELED BY APPLICANT VIA PHONE CALL ______________________________________________________________________________________________________________ 6/4/2024 - PREVIOUS INSPECTION NOTES ** 06/03/24 CULVERT PIPE NEEDS TO BE SET AT 8 FEET FROM TH EDGE OF ROAD Swale Plan #2. The swale centerline is typically located 8 feet from the edge of pavement, 5 feet from e.o.p. in cul de sacs. Culverts in cul de sacs may require a 22.5° elbow. | |||
| ROW- PRE-APRON (PRE-POUR) | 06/11/2024 | Disapproved -FEE REQUIRED | EMADISON |
| Note: ** 06/11/24 THERE NEEDS TO BE A MINIMUM OF 4 INCHES OF CONCRETE IN THE DRIVEWAY ABOVE THE ROW SEE STRINGLINES LEFT IN PLACE ** NEED TO EITHER EXTEND FORM BOARDS TO GROUND OR BACK FILL AROUND FORMS TO CONTAIN THE CONCRETE WITHIN THE POUR AREA ___________________________________________________________________________________________________________________ 6/6/2024 - PREVIOUS INSPECTION NOTES ** 06/06/24 CANCELED BY APPLICANT VIA PHONE CALL ______________________________________________________________________________________________________________ 6/4/2024 - PREVIOUS INSPECTION NOTES ** 06/03/24 CULVERT PIPE NEEDS TO BE SET AT 8 FEET FROM TH EDGE OF ROAD Swale Plan #2. The swale centerline is typically located 8 feet from the edge of pavement, 5 feet from e.o.p. in cul de sacs. Culverts in cul de sacs may require a 22.5° elbow. | |||
| ROW- PRE-APRON (PRE-POUR) | 06/06/2024 | CANCELLED BY APPLICANT | EMADISON |
| Note: ** 06/06/24 CANCELED BY APPLICANT VIA PHONE CALL ______________________________________________________________________________________________________________ 6/4/2024 - PREVIOUS INSPECTION NOTES ** 06/03/24 CULVERT PIPE NEEDS TO BE SET AT 8 FEET FROM TH EDGE OF ROAD Swale Plan #2. The swale centerline is typically located 8 feet from the edge of pavement, 5 feet from e.o.p. in cul de sacs. Culverts in cul de sacs may require a 22.5° elbow. | |||
| ROW- PRE-APRON (PRE-POUR) | 06/04/2024 | Disapproved -FEE REQUIRED | EMADISON |
| Note: ** 06/03/24 CULVERT PIPE NEEDS TO BE SET AT 8 FEET FROM TH EDGE OF ROAD Swale Plan #2. The swale centerline is typically located 8 feet from the edge of pavement, 5 feet from e.o.p. in cul de sacs. Culverts in cul de sacs may require a 22.5° elbow. | |||
| PEP TANK INSTALLATION REQUEST | 05/03/2024 | APPROVED | CBOWERMASTER |
| INSULATION | 03/27/2024 | APPROVED | FWILLIS |
| Note: Inspector Notes from Inspection 2420 3/13/24- 1. Previous note partially rectified......Hood exhaust duct at Kitchen Cut wall needs to be strapped together, and NP at Master closet ceiling line. FBC 602.6.1...50 %of its width, a galvanized metal tie not less than (16ga) and 1 1/2" wide shall be fastened across and to the plate at each side of the opening...... ( TP strap needs to be both sides of wall, and NP was not installed. 2. Please install mechanical fastener at Lanai bathroom exhaust duct at fan assembly. FBMC 603.9 Joints, seams and connections. 3. Please install gasket at face of all supply and return registers for sealing between drywall and boot. FBEC R402.4.1.1 Will check at insulation. 2/8/2024 - PREVIOUS INSPECTION NOTES 2/8/24- Previous Notes Not rectified......1. Power service Line needs connected at Breaker panel. 3. Need to install approved NP at Mechanicals and Plumbing (size and Gauge).M1502.5 Protection required/ P2603.2.1 Protection against physical damage (at master shower) 5. Lanai exhaust duct needs sealed at roof sheathing. Adding the following......Hood exhaust duct at Kitchen Cut wall needs to be strapped together, and NP at Master closet ceiling line. FBC 602.6.1...50 %of its width, a galvanized metal tie not less than (16ga) and 1 1/2" wide shall be fastened across and to the plate at each side of the opening......... Please obtain a revision of energy calcs for windows installed (listed Metal / Vinyl installed/ Ufactor rating, and SHGC Rating dont match) STOPPED INSPECTION. 1/26/2024 - PREVIOUS INSPECTION NOTES 1/26/24- 1. Power service Line needs connected at Breaker panel. 2. All metal boxes need to be bonded with approved screw.NEC 250.126. 3. Need to install approved NP at Mechanicals and Plumbing (size and Gauge).M1502.5 Protection required/ P2603.2.1 Protection against physical damage 4. Dryer exhaust duct needs sealed at roof sheathing. 5. Lanai exhaust duct needs sealed at roof sheathing. 6. Ducts and plenums need to be sealed 100%. FBCM.603.1 Stopped inspection......Please walk the house for other discrepancies before calling in Inspection. | |||
| ALL ROUGH | 03/13/2024 | APPROVED - AS NOTED | JSTEWART |
| Note: 3/13/24- 1. Previous note partially rectified......Hood exhaust duct at Kitchen Cut wall needs to be strapped together, and NP at Master closet ceiling line. FBC 602.6.1...50 %of its width, a galvanized metal tie not less than (16ga) and 1 1/2" wide shall be fastened across and to the plate at each side of the opening...... ( TP strap needs to be both sides of wall, and NP was not installed. 2. Please install mechanical fastener at Lanai bathroom exhaust duct at fan assembly. FBMC 603.9 Joints, seams and connections. 3. Please install gasket at face of all supply and return registers for sealing between drywall and boot. FBEC R402.4.1.1 Will check at insulation. 2/8/2024 - PREVIOUS INSPECTION NOTES 2/8/24- Previous Notes Not rectified......1. Power service Line needs connected at Breaker panel. 3. Need to install approved NP at Mechanicals and Plumbing (size and Gauge).M1502.5 Protection required/ P2603.2.1 Protection against physical damage (at master shower) 5. Lanai exhaust duct needs sealed at roof sheathing. Adding the following......Hood exhaust duct at Kitchen Cut wall needs to be strapped together, and NP at Master closet ceiling line. FBC 602.6.1...50 %of its width, a galvanized metal tie not less than (16ga) and 1 1/2" wide shall be fastened across and to the plate at each side of the opening......... Please obtain a revision of energy calcs for windows installed (listed Metal / Vinyl installed/ Ufactor rating, and SHGC Rating dont match) STOPPED INSPECTION. 1/26/2024 - PREVIOUS INSPECTION NOTES 1/26/24- 1. Power service Line needs connected at Breaker panel. 2. All metal boxes need to be bonded with approved screw.NEC 250.126. 3. Need to install approved NP at Mechanicals and Plumbing (size and Gauge).M1502.5 Protection required/ P2603.2.1 Protection against physical damage 4. Dryer exhaust duct needs sealed at roof sheathing. 5. Lanai exhaust duct needs sealed at roof sheathing. 6. Ducts and plenums need to be sealed 100%. FBCM.603.1 Stopped inspection......Please walk the house for other discrepancies before calling in Inspection. | |||
| ALL ROUGH | 02/08/2024 | Disapproved -FEE REQUIRED | JSTEWART |
| Note: 2/8/24- Previous Notes Not rectified......1. Power service Line needs connected at Breaker panel. 3. Need to install approved NP at Mechanicals and Plumbing (size and Gauge).M1502.5 Protection required/ P2603.2.1 Protection against physical damage (at master shower) 5. Lanai exhaust duct needs sealed at roof sheathing. Adding the following......Hood exhaust duct at Kitchen Cut wall needs to be strapped together, and NP at Master closet ceiling line. FBC 602.6.1...50 %of its width, a galvanized metal tie not less than (16ga) and 1 1/2" wide shall be fastened across and to the plate at each side of the opening......... Please obtain a revision of energy calcs for windows installed (listed Metal / Vinyl installed/ Ufactor rating, and SHGC Rating dont match) STOPPED INSPECTION. 1/26/2024 - PREVIOUS INSPECTION NOTES 1/26/24- 1. Power service Line needs connected at Breaker panel. 2. All metal boxes need to be bonded with approved screw.NEC 250.126. 3. Need to install approved NP at Mechanicals and Plumbing (size and Gauge).M1502.5 Protection required/ P2603.2.1 Protection against physical damage 4. Dryer exhaust duct needs sealed at roof sheathing. 5. Lanai exhaust duct needs sealed at roof sheathing. 6. Ducts and plenums need to be sealed 100%. FBCM.603.1 Stopped inspection......Please walk the house for other discrepancies before calling in Inspection. | |||
| ALL ROUGH | 01/26/2024 | Disapproved -FEE REQUIRED | JSTEWART |
| Note: 1/26/24- 1. Power service Line needs connected at Breaker panel. 2. All metal boxes need to be bonded with approved screw.NEC 250.126. 3. Need to install approved NP at Mechanicals and Plumbing (size and Gauge).M1502.5 Protection required/ P2603.2.1 Protection against physical damage 4. Dryer exhaust duct needs sealed at roof sheathing. 5. Lanai exhaust duct needs sealed at roof sheathing. 6. Ducts and plenums need to be sealed 100%. FBCM.603.1 Stopped inspection......Please walk the house for other discrepancies before calling in Inspection. | |||
| LATH/BRICK/ WATER BARRIER | 01/25/2024 | APPROVED | FWILLIS |
| WALL SHEATHING | 01/25/2024 | APPROVED | FWILLIS |
| ROOF VALLEY & METAL | 08/23/2023 | APPROVED | JSTEWART |
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 08/22/2023 | APPROVED | FWILLIS |
| FOUND SURVEY APPROVED (OFFICE) | 08/16/2023 | APPROVED | TBAKER |
| TIE BEAM / LINTEL | 04/13/2023 | APPROVED | JSTEWART |
| MONOLITHIC SLAB | 03/08/2023 | APPROVED | JSTEWART |
| Note: 3/7/2023 - PREVIOUS INSPECTION NOTES 3/7/2023--FORMS SHALL PROVIDE SUFFICIENT STRENGTH TO CONTAIN CONCRETE DURING THE CONCRETE PLACEMENT OPERATION (STAY IN PLACE FORMS) FBC404.1.2.3.6 CLEARANCE ON REBAR FROM EARTH 3” FBC R404.1.2.3.7.4 (highlighted on print) R319.1 Address identification. Buildings shall be provided with approved address identification. The address identification shall be legible and placed in a position that is visible from the street or road fronting the property. Address identification characters shall contrast with their background. Address numbers shall be Arabic numbers or alphabetical letters. Numbers shall not be spelled out. Each character shall be not less than 4 inches (102 mm) in height with a stroke width of not less than 0.5 inch (12.7 mm) | |||
| MONOLITHIC SLAB | 03/07/2023 | Disapproved - NO FEE | JSTEWART |
| Note: 3/7/2023--FORMS SHALL PROVIDE SUFFICIENT STRENGTH TO CONTAIN CONCRETE DURING THE CONCRETE PLACEMENT OPERATION (STAY IN PLACE FORMS) FBC404.1.2.3.6 CLEARANCE ON REBAR FROM EARTH 3” FBC R404.1.2.3.7.4 (highlighted on print) R319.1 Address identification. Buildings shall be provided with approved address identification. The address identification shall be legible and placed in a position that is visible from the street or road fronting the property. Address identification characters shall contrast with their background. Address numbers shall be Arabic numbers or alphabetical letters. Numbers shall not be spelled out. Each character shall be not less than 4 inches (102 mm) in height with a stroke width of not less than 0.5 inch (12.7 mm) | |||
| PLUMBING 1ST ROUGH UNDERGROUND | 01/24/2023 | APPROVED - AS NOTED | MGIBSON |
| Note: NEED PORTABLE RESTROOM BY NEXT INSPECTION | |||
| FOOTER | 12/21/2022 | APPROVED | RMARTIN |
| WATER METER INSTALLATION REQUEST | 06/16/2022 | APPROVED | CSTONE |
Review History
| Department | Status | Date In | Date Out |
| MECH | COMPLETE | 08/11/2025 | 08/12/2025 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| BADMIN | INFORMATION | 06/25/2025 | 06/25/2025 |
| Note: Marked INFORMATION By: LIBBY RAYBURN - - LRAYBURN@PALMCOASTGOV.COM wrong type chosen for a final survey you need to pick final survey | |||
| BADMIN | INFORMATION | 09/16/2024 | 09/16/2024 |
| Note: Marked INFORMATION By: BARBIE BEMBRY - (386)986-3780 - BUILDINGDIVISION@PALMCOASTGOV.COM subcontractors are to be managed through the online portal - see the last page of the 'how to use'.... guide for instructions. | |||
| BADMIN | INFORMATION | 03/12/2024 | 03/12/2024 |
| Note: Marked INFORMATION By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM license provided is incorrect | |||
| MECH | COMPLETE | 03/11/2024 | 03/12/2024 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 03/06/2024 | 03/06/2024 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| ZON | HOLD | 03/06/2024 | 03/06/2024 |
| Note: Held By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM Survey submitted is not for this address | |||
| BLD | COMPLETE | 01/09/2024 | 01/12/2024 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 08/15/2023 | 08/16/2023 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 08/15/2023 | 08/16/2023 |
| Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 04/29/2022 | 04/29/2022 |
| Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM | |||
| SWALE | COMPLETE | 04/27/2022 | 06/23/2022 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 04/26/2022 | 04/28/2022 |
| Note: Released By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM | |||
| CUSVC | COMPLETE | 04/26/2022 | 04/29/2022 |
| Note: Released By: ALYSSA ROSCOE - - | |||
| ELEC | COMPLETE | 04/26/2022 | 04/27/2022 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 04/26/2022 | 04/27/2022 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| LOCATE | COMPLETE | 04/26/2022 | 05/03/2022 |
| Note: Released By: CANDACE STONE - - CSTONE@PALMCOASTGOV.COM | |||
| MECH | COMPLETE | 04/26/2022 | 04/26/2022 |
| Note: Released By: CHRIS PISCITELLI - (386)986-3782 - CPISCITELLI@PALMCOASTGOV.COM | |||
| SW1 | COMPLETE | 04/26/2022 | 05/02/2022 |
| Note: Released By: EDWARD MADISON - - EMADISON@PALMCOASTGOV.COM | |||
| ZON | HOLD | 04/26/2022 | 04/27/2022 |
| Note: Held By: CINDY CHIRI-GONCALVES - - CGONCALVES@PALMCOASTGOV.COM Site Plan: A/C pad is missing on proposed site plan. Please show location, dimensions and setbacks of pad demonstrating that it does not encroach in the easement. Also note that site plan and landscape plan must match |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| WATER- TURN ON | ¤25.00 | 05/16/2022 |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | 05/16/2022 |
| INSPECTION - RESIDENTIAL | ¤852.50 | 05/16/2022 |
| PLAN REVIEW - RESIDENTIAL | ¤241.80 | 05/16/2022 |
| CONNECTION FEES | ¤1,077.88 | 05/16/2022 |
| 3% FIRE IMPACT FEE CREDIT | (¤11.66) | 05/16/2022 |
| IMPACT FEE FIRE | ¤388.65 | 05/16/2022 |
| IMPACT FEE PARKS | ¤1,455.13 | 05/16/2022 |
| IMPACT FEE SCHOOL | ¤3,600.00 | 05/16/2022 |
| IMPACT FEE TRANSPORTATION | ¤1,764.00 | 05/16/2022 |
| WATER -IRRIGATION INSPECTION | ¤25.00 | 05/16/2022 |
| 3% PARKS IMPACT FEE CREDIT | (¤43.65) | 05/16/2022 |
| SURCHARGE FS 533.721 | ¤11.84 | 05/16/2022 |
| SURCHARGE - FS 468.631 | ¤17.76 | 05/16/2022 |
| SW ENG - FOUNDATION SURVEY | ¤20.00 | 05/16/2022 |
| SW ENG INSPECTION 80 | ¤80.00 | 05/16/2022 |
| SW ENG PRE APRON | ¤30.00 | 05/16/2022 |
| SW ENG - REVIEW 20 | ¤20.00 | 05/16/2022 |
| SW ENG RES REVIEW 200 | ¤200.00 | 05/16/2022 |
| 3% TRANS IMPACT FEE CREDIT | (¤52.92) | 05/16/2022 |
| SEWER CREDIT | (¤850.00) | 05/16/2022 |
| SEWER INSPECTION | ¤25.00 | 05/16/2022 |
| SEWER CAPITAL FACILITY | ¤4,939.76 | 05/16/2022 |
| WATER CAPITAL FACILITY FEE | ¤3,626.50 | 05/16/2022 |
| SITE PLAN 30 | ¤30.00 | 05/16/2022 |
| SW ENG REINSPECTION 30 | ¤30.00 | |
| SW ENG REINSPECTION 30 | ¤30.00 | |
| CONTRACTOR CHANGE | ¤20.00 | |
| CONTRACTOR CHANGE | ¤20.00 | |
| CONTRACTOR CHANGE | ¤20.00 | |
| REINSPECTION RESIDENTIAL | ¤40.00 | |
| REINSPECTION RESIDENTIAL | ¤40.00 | |
| REINSPECTION RESIDENTIAL | ¤40.00 | |
| Fees | Total Due: ¤240.00 | Total Paid: ¤17,502.59 |