I want to search for...

Permit #2022041527

Permit Details

Status: COED

Parcel Id: 07-11-31-7009-00250-0190
GARAGE: 466 sqft
SCREEN PORCH (SOLID ROOF) : 584 sqft
OPENED PORCH (WITH ROOF) : 186 sqft
CONDITIONED SPACE: 2138 sqft
Total Square Footage: 3374 sqft
Block: 00250
Subdivision: 2208 - SECTION 9-FLORIDA PARK
Job Phone: 774-696-6541
Location Address: 33 FALLON LN
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 06/28/2022
NOC: RECORDED
Applicant name: JOHN DESMOND
Owner: 33 FALLON LAND LLC

Address

2582 MAGUIRE RD #411

OCOEE, FL 34761

Lot: 0190
Contracted Stated Job Value: ¤250,000.00
Job Description: SINGLE FAMILY RESIDENCE
Type: CN

Contractor

COMPLETE BUILDERS LLC
Status Location Address State License Number Phone
INACTIVE

15 CHERRYTREE CT

PALM COAST, FL 32137

CGC1530956 (Exp: 08/31/2026) 774-696-6541

Sub Contractors

JOSEPH C WRIGHT
Status Location Address Mailing Address State License Number Phone Fax
ACTIVE

15 HARGROVE LANE

PALM COAST, FL 32137

UNIT 3 D

PALM COAST, FL 32137

EC13003278 (Exp: 08/31/2026) 386-447-9644 386-447-9633
GARY LLOYD SHEFFIELD
Status Location Address State License Number Phone
ACTIVE

48 EAGLE LAKES DRIVE

FLAGLER BEACH, FL 32136

CAC048127 (Exp: 08/31/2026) 386-597-3280
IAN MICHEAL JOHNSON
Status Location Address State License Number Phone Fax
ACTIVE

4244 JACKSON STREET

PORT ORANGE, FL 32127

CCC1325915 (Exp: 08/31/2026) 386-760-0764 386-760-3080
JONATHAN M PEARSON
Status Location Address State License Number Phone Fax
ACTIVE

209 N FORSYTH ST

BUNNELL, FL 32110

CFC1425941 (Exp: 08/31/2026) 386-597-0944 386-437-4996

Inspection History

Type Request Date Result Inspector
BLD - BUILDING FINAL 09/18/2023 FINAL APPROVED AGAETANO
Note: 9/14/2023 - PREVIOUS INSPECTION NOTES Inspector Notes from Inspection 2320 02-13-2023 R319.1 Address identification. Buildings shall be provided with approved address identification. The address identification shall be legible and placed in a position that is visiblen from the street or road fronting the property. Address identification characters shall contrast with their background. Address numbers shall be Arabic numbers or alphabetical letters. Numbers shall not be spelled out. Each character shall be not less than 4 inches (102 mm) in height with a stroke width of not less than 0.5 inch (12.7 mm). Where required by the fire code official, address identification shall be provided in additional approved locations to facilitate emergency response. Where access is by means of a private road and the building address cannot be viewed from the public way, a monument, pole or other sign or means shall be used to identify the structure. Address identification shall be maintained. 09-14-2023 1. Energy calcs do not match. Please submit to the building department and have approved calcs on site for inspection. 2. AC pad clearance not met. 3" required at the grass area.
BLD - BUILDING FINAL 09/14/2023 Disapproved - NO FEE AGAETANO
Note: Inspector Notes from Inspection 2320 02-13-2023 R319.1 Address identification. Buildings shall be provided with approved address identification. The address identification shall be legible and placed in a position that is visiblen from the street or road fronting the property. Address identification characters shall contrast with their background. Address numbers shall be Arabic numbers or alphabetical letters. Numbers shall not be spelled out. Each character shall be not less than 4 inches (102 mm) in height with a stroke width of not less than 0.5 inch (12.7 mm). Where required by the fire code official, address identification shall be provided in additional approved locations to facilitate emergency response. Where access is by means of a private road and the building address cannot be viewed from the public way, a monument, pole or other sign or means shall be used to identify the structure. Address identification shall be maintained. 09-14-2023 1. Energy calcs do not match. Please submit to the building department and have approved calcs on site for inspection. 2. AC pad clearance not met. 3" required at the grass area.
ROW - FINAL APRON (AFTER POUR) 09/13/2023 FINAL APPROVED EMADISON
ROW - STORMWATER FINAL 09/13/2023 FINAL APPROVED EMADISON
U -UTILITY RESIDENTIAL FINAL 09/13/2023 FINAL APPROVED DHANEY
ROW FIELD SURVEY /GRADING CERTIFICATION 09/12/2023 APPROVED EMADISON
Note: ** 09/12/23 NEED TO CLEAN CULVERT ENDS
ROW- FINAL SURVEY/GRADING CERTIFICATION 09/12/2023 APPROVED EMADISON
Note: ** 09/12/23 CORRECTIONS MADE _______________________________________________________________________________________________________________ 9/8/2023 - PREVIOUS INSPECTION NOTES ** 09/08/23 THERE IS NO NEW SUBMITTED FINAL SURVEY FOR INSPECTOR TO REVIEW . __________________________________________________________________________________________________________________ 9/1/2023 - PREVIOUS INSPECTION NOTES ** 09/01/23 NO CHANGES TO FINAL SURVEY FROM PREVIOUS SUBMITTED FINAL SURVEYS * Unless specifically stated the subject lot must drain from back to front or a portion may be drained to an adjacent City drainage feature. (B)?The subject lots drainage must not negatively impact any adjacent property. (B)?The front property line/right away elevation are to be equal to or greater than the ** Sod elevations adjacent to the structure are 4” below the FFE for block and 6” for wood frame structures. (D)?Drainage from the structure is to be a 6 inch (5%) minimum slope for the first 10’.(E) ** F.F.E. NEEDED FOR ADJACENT IMPROVED PROPERTY IN THE REAR ** ALL F.F.E AND HARDSHOTS NEED TO BE TO THE .01 _________________________________________________________________________________________________________________________ 8/15/2023 - PREVIOUS INSPECTION NOTES ** 08/15/23 NEED TO READ THE INSPECTOR NOTES ________________________________________________________________________________________________________________ 8/3/2023 - PREVIOUS INSPECTION NOTES ** 08/03/23Drainage from the structure is to be a 6 inch (5%) minimum slope for the first 10’.(E) Elevations on all adjacent properties at a minimum of 20-foot intervals, on a 10 foot offset, outside the property lines. (A) Existing interior elevations on a 20’ grid. (E) ** 7/20/2023 - PREVIOUS INSPECTION NOTES ** 07/20/23 ** ADJACENT DRIVEWAY CULVERTS AND DRAINAGE FEATURES: FINAL SURVEY MUST INCLUDE THE INVERTS OF ADJACENT DEVELOPED PROPERTY DRIVEWAY CULVERTS AND ANY OTHER DRAINAGE FEATURE WITHIN 100 FEET OF THE PROPERTY LINES. 7/11/2023 - PREVIOUS INSPECTION NOTES ** 07/11/23 NEED TO READ ALL INSPECTOR NOTES FROM PREVIOUS (2) TWO FINAL SURVEY INSPECTIONS ** NEED TO SUBMIT A NEW FINAL SURVEY WITH ALL REQUIRED CORRECTIONS _______________________________________________________________________________________________________________________ 6/30/2023 - PREVIOUS INSPECTION NOTES 6/30/23=Drainage from the structure is to be a 6 inch (5%) minimum slope for the first 10’.(E) Elevations on all adjacent properties at a minimum of 20-foot intervals, on a 10 foot offset, outside the property lines. (A) Existing interior elevations on a 20’ grid. (E) The front property line/right away elevation are to be equal to or greater than the centerline of the road elevation. (I) NEED TO READ THE PREVIOUS NOTES AND SUBMIT A NEW FINAL SURVEY . ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 6/21/2023 - PREVIOUS INSPECTION NOTES ** 06/01/23 NEED ELEVATION SHOTS ON ALL ADJACENT PROPERTY LINES AT 20 FOOT INTERVALS AND ACROSS SUBJECT LOTS FRONT PROPERTY LINE TO DETERMINE IF EQUAL OR HIGHER THAN THE CENTERLINE OF ROAD ** NEED F.F.E. SHOTS ON ALL ADJACENT PROPERTIES SIDES AND REAR ** ELEVATIONS ON ALL ADJACENT PROPERTIES AT A MINIMUM OF 20 FOOT INTERVALS ON 10 FOOT OFF-SET OUTSIDE THE PROPERTY LINE (LEFT SIDE) ** F.F.E. SHOTS AND ALL OTHER HARD SHOTS NEED TO BE TO THE 100th ** ADJACENT DRIVEWAY CULVERTS AND DRAINAGE FEATURES: FINAL SURVEY MUST INCLUDE THE INVERTS OF ADJACENT DEVELOPED PROPERTY DRIVEWAY CULVERTS AND ANY OTHER DRAINAGE FEATURE WITHIN 100 FEET OF THE PROPERTY LINES. ** SOD ELEVATIONS ADJACENT TO THE STRUCTURE ARE 4 INCHES BELOW F.F.E. FOR FOR CONCRETE BLOCK AND 6 INCHES BELOW FOR WOOD FRAME STRUCTURES NEED TO IDENTIFY TYPE OF STRUCTURE AND ELEVATIONS IN ALL FOUR (4) CORNERS ** THE SUBJECT LOTS DRAINAGE MUST NOT NEGATIVELY IMPACT ANY ADJACENT PROPERTIES (RIGHT SIDE) _____________________________________________________________________________________________________________________ 6/1/2023 - PREVIOUS INSPECTION NOTES ** 06/01/23 NEED ELEVATION SHOTS ON ALL ADJACENT PROPERTY LINES AT 20 FOOT INTERVALS ** CHECK RIGHT SIDE NEED FINAL ELEVATION SHOTS ON A 20 FOOT GRID INSIDE PROPERTY LINE ** ELEVATIONS ON ALL ADJACENT PROPERTIES AT A MINIMUM OF 20 FOOT INTERVALS ON 10 FOOT OFF-SET OUTSIDE THE PROPERTY LINE ** F.F.E. SHOTS AND ALL OTHER HARD SHOTS NEED TO BE TO THE 100th ** ADJACENT DRIVEWAY CULVERTS AND DRAINAGE FEATURES: FINAL SURVEY MUST INCLUDE THE INVERTS OF ADJACENT DEVELOPED PROPERTY DRIVEWAY CULVERTAND ANY OTHER DRAINAGE FEATURE WITHIN 100 FEET OF THE PROPERTY LINES. ** SOD ELEVATIONS ADJACENT TO THE STRUCTURE ARE 4 INCHES BELOW F.F.E. FOR FOR CONCRETE BLOCK AND 6 INCHES BELOW FOR WOOD FRAME STRUCTURES NEED TO IDENTIFY TYPE OF STRUCTURE ** THE SUBJECT LOTS DRAINAGE MUST NOT NEGATIVELY IMPACT ANY ADJACENT PROPERTIES (RIGHT SIDE)
ROW- FINAL SURVEY/GRADING CERTIFICATION 09/08/2023 Disapproved - NO FEE EMADISON
Note: ** 09/08/23 THERE IS NO NEW SUBMITTED FINAL SURVEY FOR INSPECTOR TO REVIEW . __________________________________________________________________________________________________________________ 9/1/2023 - PREVIOUS INSPECTION NOTES ** 09/01/23 NO CHANGES TO FINAL SURVEY FROM PREVIOUS SUBMITTED FINAL SURVEYS * Unless specifically stated the subject lot must drain from back to front or a portion may be drained to an adjacent City drainage feature. (B)?The subject lots drainage must not negatively impact any adjacent property. (B)?The front property line/right away elevation are to be equal to or greater than the ** Sod elevations adjacent to the structure are 4” below the FFE for block and 6” for wood frame structures. (D)?Drainage from the structure is to be a 6 inch (5%) minimum slope for the first 10’.(E) ** F.F.E. NEEDED FOR ADJACENT IMPROVED PROPERTY IN THE REAR ** ALL F.F.E AND HARDSHOTS NEED TO BE TO THE .01 _________________________________________________________________________________________________________________________ 8/15/2023 - PREVIOUS INSPECTION NOTES ** 08/15/23 NEED TO READ THE INSPECTOR NOTES ________________________________________________________________________________________________________________ 8/3/2023 - PREVIOUS INSPECTION NOTES ** 08/03/23Drainage from the structure is to be a 6 inch (5%) minimum slope for the first 10’.(E) Elevations on all adjacent properties at a minimum of 20-foot intervals, on a 10 foot offset, outside the property lines. (A) Existing interior elevations on a 20’ grid. (E) ** 7/20/2023 - PREVIOUS INSPECTION NOTES ** 07/20/23 ** ADJACENT DRIVEWAY CULVERTS AND DRAINAGE FEATURES: FINAL SURVEY MUST INCLUDE THE INVERTS OF ADJACENT DEVELOPED PROPERTY DRIVEWAY CULVERTS AND ANY OTHER DRAINAGE FEATURE WITHIN 100 FEET OF THE PROPERTY LINES. 7/11/2023 - PREVIOUS INSPECTION NOTES ** 07/11/23 NEED TO READ ALL INSPECTOR NOTES FROM PREVIOUS (2) TWO FINAL SURVEY INSPECTIONS ** NEED TO SUBMIT A NEW FINAL SURVEY WITH ALL REQUIRED CORRECTIONS _______________________________________________________________________________________________________________________ 6/30/2023 - PREVIOUS INSPECTION NOTES 6/30/23=Drainage from the structure is to be a 6 inch (5%) minimum slope for the first 10’.(E) Elevations on all adjacent properties at a minimum of 20-foot intervals, on a 10 foot offset, outside the property lines. (A) Existing interior elevations on a 20’ grid. (E) The front property line/right away elevation are to be equal to or greater than the centerline of the road elevation. (I) NEED TO READ THE PREVIOUS NOTES AND SUBMIT A NEW FINAL SURVEY . ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 6/21/2023 - PREVIOUS INSPECTION NOTES ** 06/01/23 NEED ELEVATION SHOTS ON ALL ADJACENT PROPERTY LINES AT 20 FOOT INTERVALS AND ACROSS SUBJECT LOTS FRONT PROPERTY LINE TO DETERMINE IF EQUAL OR HIGHER THAN THE CENTERLINE OF ROAD ** NEED F.F.E. SHOTS ON ALL ADJACENT PROPERTIES SIDES AND REAR ** ELEVATIONS ON ALL ADJACENT PROPERTIES AT A MINIMUM OF 20 FOOT INTERVALS ON 10 FOOT OFF-SET OUTSIDE THE PROPERTY LINE (LEFT SIDE) ** F.F.E. SHOTS AND ALL OTHER HARD SHOTS NEED TO BE TO THE 100th ** ADJACENT DRIVEWAY CULVERTS AND DRAINAGE FEATURES: FINAL SURVEY MUST INCLUDE THE INVERTS OF ADJACENT DEVELOPED PROPERTY DRIVEWAY CULVERTS AND ANY OTHER DRAINAGE FEATURE WITHIN 100 FEET OF THE PROPERTY LINES. ** SOD ELEVATIONS ADJACENT TO THE STRUCTURE ARE 4 INCHES BELOW F.F.E. FOR FOR CONCRETE BLOCK AND 6 INCHES BELOW FOR WOOD FRAME STRUCTURES NEED TO IDENTIFY TYPE OF STRUCTURE AND ELEVATIONS IN ALL FOUR (4) CORNERS ** THE SUBJECT LOTS DRAINAGE MUST NOT NEGATIVELY IMPACT ANY ADJACENT PROPERTIES (RIGHT SIDE) _____________________________________________________________________________________________________________________ 6/1/2023 - PREVIOUS INSPECTION NOTES ** 06/01/23 NEED ELEVATION SHOTS ON ALL ADJACENT PROPERTY LINES AT 20 FOOT INTERVALS ** CHECK RIGHT SIDE NEED FINAL ELEVATION SHOTS ON A 20 FOOT GRID INSIDE PROPERTY LINE ** ELEVATIONS ON ALL ADJACENT PROPERTIES AT A MINIMUM OF 20 FOOT INTERVALS ON 10 FOOT OFF-SET OUTSIDE THE PROPERTY LINE ** F.F.E. SHOTS AND ALL OTHER HARD SHOTS NEED TO BE TO THE 100th ** ADJACENT DRIVEWAY CULVERTS AND DRAINAGE FEATURES: FINAL SURVEY MUST INCLUDE THE INVERTS OF ADJACENT DEVELOPED PROPERTY DRIVEWAY CULVERTAND ANY OTHER DRAINAGE FEATURE WITHIN 100 FEET OF THE PROPERTY LINES. ** SOD ELEVATIONS ADJACENT TO THE STRUCTURE ARE 4 INCHES BELOW F.F.E. FOR FOR CONCRETE BLOCK AND 6 INCHES BELOW FOR WOOD FRAME STRUCTURES NEED TO IDENTIFY TYPE OF STRUCTURE ** THE SUBJECT LOTS DRAINAGE MUST NOT NEGATIVELY IMPACT ANY ADJACENT PROPERTIES (RIGHT SIDE)
ROW FIELD SURVEY /GRADING CERTIFICATION 09/08/2023 Disapproved - NO FEE EMADISON
Note: ** 09/08/23 NEED TO HAVE A FINAL SURVEY REVIEWED AND APPROVED FOR A FIELD SURVEY INSPECTION _________________________________________________________________________________________________________________ 7/10/2023 - PREVIOUS INSPECTION NOTES ** 07/10/23 FINAL SURVEY MUST BE COMPLETED AND APPROVED BEFORE THE FIELD SURVEY CAN BE SCHEDULED _________________________________________________________________________________________________________________________ 6/1/2023 - PREVIOUS INSPECTION NOTES ** 06/01/23 FINAL SURVEY MUST BE APPROVED BEFORE A FIELD SURVEY INSPECTION CAN BE DONE INSPECTOR WILL CREATE THE FIELD SURVEY ONCE HE APPROVES THE FINAL SURVEY
ROW- FINAL SURVEY/GRADING CERTIFICATION 09/01/2023 Disapproved -FEE REQUIRED EMADISON
Note: ** 09/01/23 NO CHANGES TO FINAL SURVEY FROM PREVIOUS SUBMITTED FINAL SURVEYS * Unless specifically stated the subject lot must drain from back to front or a portion may be drained to an adjacent City drainage feature. (B)?The subject lots drainage must not negatively impact any adjacent property. (B)?The front property line/right away elevation are to be equal to or greater than the ** Sod elevations adjacent to the structure are 4” below the FFE for block and 6” for wood frame structures. (D)?Drainage from the structure is to be a 6 inch (5%) minimum slope for the first 10’.(E) ** F.F.E. NEEDED FOR ADJACENT IMPROVED PROPERTY IN THE REAR ** ALL F.F.E AND HARDSHOTS NEED TO BE TO THE .01 _________________________________________________________________________________________________________________________ 8/15/2023 - PREVIOUS INSPECTION NOTES ** 08/15/23 NEED TO READ THE INSPECTOR NOTES ________________________________________________________________________________________________________________ 8/3/2023 - PREVIOUS INSPECTION NOTES ** 08/03/23Drainage from the structure is to be a 6 inch (5%) minimum slope for the first 10’.(E) Elevations on all adjacent properties at a minimum of 20-foot intervals, on a 10 foot offset, outside the property lines. (A) Existing interior elevations on a 20’ grid. (E) ** 7/20/2023 - PREVIOUS INSPECTION NOTES ** 07/20/23 ** ADJACENT DRIVEWAY CULVERTS AND DRAINAGE FEATURES: FINAL SURVEY MUST INCLUDE THE INVERTS OF ADJACENT DEVELOPED PROPERTY DRIVEWAY CULVERTS AND ANY OTHER DRAINAGE FEATURE WITHIN 100 FEET OF THE PROPERTY LINES. 7/11/2023 - PREVIOUS INSPECTION NOTES ** 07/11/23 NEED TO READ ALL INSPECTOR NOTES FROM PREVIOUS (2) TWO FINAL SURVEY INSPECTIONS ** NEED TO SUBMIT A NEW FINAL SURVEY WITH ALL REQUIRED CORRECTIONS _______________________________________________________________________________________________________________________ 6/30/2023 - PREVIOUS INSPECTION NOTES 6/30/23=Drainage from the structure is to be a 6 inch (5%) minimum slope for the first 10’.(E) Elevations on all adjacent properties at a minimum of 20-foot intervals, on a 10 foot offset, outside the property lines. (A) Existing interior elevations on a 20’ grid. (E) The front property line/right away elevation are to be equal to or greater than the centerline of the road elevation. (I) NEED TO READ THE PREVIOUS NOTES AND SUBMIT A NEW FINAL SURVEY . ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 6/21/2023 - PREVIOUS INSPECTION NOTES ** 06/01/23 NEED ELEVATION SHOTS ON ALL ADJACENT PROPERTY LINES AT 20 FOOT INTERVALS AND ACROSS SUBJECT LOTS FRONT PROPERTY LINE TO DETERMINE IF EQUAL OR HIGHER THAN THE CENTERLINE OF ROAD ** NEED F.F.E. SHOTS ON ALL ADJACENT PROPERTIES SIDES AND REAR ** ELEVATIONS ON ALL ADJACENT PROPERTIES AT A MINIMUM OF 20 FOOT INTERVALS ON 10 FOOT OFF-SET OUTSIDE THE PROPERTY LINE (LEFT SIDE) ** F.F.E. SHOTS AND ALL OTHER HARD SHOTS NEED TO BE TO THE 100th ** ADJACENT DRIVEWAY CULVERTS AND DRAINAGE FEATURES: FINAL SURVEY MUST INCLUDE THE INVERTS OF ADJACENT DEVELOPED PROPERTY DRIVEWAY CULVERTS AND ANY OTHER DRAINAGE FEATURE WITHIN 100 FEET OF THE PROPERTY LINES. ** SOD ELEVATIONS ADJACENT TO THE STRUCTURE ARE 4 INCHES BELOW F.F.E. FOR FOR CONCRETE BLOCK AND 6 INCHES BELOW FOR WOOD FRAME STRUCTURES NEED TO IDENTIFY TYPE OF STRUCTURE AND ELEVATIONS IN ALL FOUR (4) CORNERS ** THE SUBJECT LOTS DRAINAGE MUST NOT NEGATIVELY IMPACT ANY ADJACENT PROPERTIES (RIGHT SIDE) _____________________________________________________________________________________________________________________ 6/1/2023 - PREVIOUS INSPECTION NOTES ** 06/01/23 NEED ELEVATION SHOTS ON ALL ADJACENT PROPERTY LINES AT 20 FOOT INTERVALS ** CHECK RIGHT SIDE NEED FINAL ELEVATION SHOTS ON A 20 FOOT GRID INSIDE PROPERTY LINE ** ELEVATIONS ON ALL ADJACENT PROPERTIES AT A MINIMUM OF 20 FOOT INTERVALS ON 10 FOOT OFF-SET OUTSIDE THE PROPERTY LINE ** F.F.E. SHOTS AND ALL OTHER HARD SHOTS NEED TO BE TO THE 100th ** ADJACENT DRIVEWAY CULVERTS AND DRAINAGE FEATURES: FINAL SURVEY MUST INCLUDE THE INVERTS OF ADJACENT DEVELOPED PROPERTY DRIVEWAY CULVERTAND ANY OTHER DRAINAGE FEATURE WITHIN 100 FEET OF THE PROPERTY LINES. ** SOD ELEVATIONS ADJACENT TO THE STRUCTURE ARE 4 INCHES BELOW F.F.E. FOR FOR CONCRETE BLOCK AND 6 INCHES BELOW FOR WOOD FRAME STRUCTURES NEED TO IDENTIFY TYPE OF STRUCTURE ** THE SUBJECT LOTS DRAINAGE MUST NOT NEGATIVELY IMPACT ANY ADJACENT PROPERTIES (RIGHT SIDE)
ROW- PROJECT STATUS 08/16/2023 APPROVED PFLANAGAN
Note: MEET ON SITE WITH SURVEYORS, BUILDER AND GRADE GUY NEED TO HAVE FALL OFF THE BACK OF HOUSE
ROW- FINAL SURVEY/GRADING CERTIFICATION 08/15/2023 Disapproved -FEE REQUIRED EMADISON
Note: ** 08/15/23 NEED TO READ THE INSPECTOR NOTES ________________________________________________________________________________________________________________ 8/3/2023 - PREVIOUS INSPECTION NOTES ** 08/03/23Drainage from the structure is to be a 6 inch (5%) minimum slope for the first 10’.(E) Elevations on all adjacent properties at a minimum of 20-foot intervals, on a 10 foot offset, outside the property lines. (A) Existing interior elevations on a 20’ grid. (E) ** 7/20/2023 - PREVIOUS INSPECTION NOTES ** 07/20/23 ** ADJACENT DRIVEWAY CULVERTS AND DRAINAGE FEATURES: FINAL SURVEY MUST INCLUDE THE INVERTS OF ADJACENT DEVELOPED PROPERTY DRIVEWAY CULVERTS AND ANY OTHER DRAINAGE FEATURE WITHIN 100 FEET OF THE PROPERTY LINES. 7/11/2023 - PREVIOUS INSPECTION NOTES ** 07/11/23 NEED TO READ ALL INSPECTOR NOTES FROM PREVIOUS (2) TWO FINAL SURVEY INSPECTIONS ** NEED TO SUBMIT A NEW FINAL SURVEY WITH ALL REQUIRED CORRECTIONS _______________________________________________________________________________________________________________________ 6/30/2023 - PREVIOUS INSPECTION NOTES 6/30/23=Drainage from the structure is to be a 6 inch (5%) minimum slope for the first 10’.(E) Elevations on all adjacent properties at a minimum of 20-foot intervals, on a 10 foot offset, outside the property lines. (A) Existing interior elevations on a 20’ grid. (E) The front property line/right away elevation are to be equal to or greater than the centerline of the road elevation. (I) NEED TO READ THE PREVIOUS NOTES AND SUBMIT A NEW FINAL SURVEY . ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 6/21/2023 - PREVIOUS INSPECTION NOTES ** 06/01/23 NEED ELEVATION SHOTS ON ALL ADJACENT PROPERTY LINES AT 20 FOOT INTERVALS AND ACROSS SUBJECT LOTS FRONT PROPERTY LINE TO DETERMINE IF EQUAL OR HIGHER THAN THE CENTERLINE OF ROAD ** NEED F.F.E. SHOTS ON ALL ADJACENT PROPERTIES SIDES AND REAR ** ELEVATIONS ON ALL ADJACENT PROPERTIES AT A MINIMUM OF 20 FOOT INTERVALS ON 10 FOOT OFF-SET OUTSIDE THE PROPERTY LINE (LEFT SIDE) ** F.F.E. SHOTS AND ALL OTHER HARD SHOTS NEED TO BE TO THE 100th ** ADJACENT DRIVEWAY CULVERTS AND DRAINAGE FEATURES: FINAL SURVEY MUST INCLUDE THE INVERTS OF ADJACENT DEVELOPED PROPERTY DRIVEWAY CULVERTS AND ANY OTHER DRAINAGE FEATURE WITHIN 100 FEET OF THE PROPERTY LINES. ** SOD ELEVATIONS ADJACENT TO THE STRUCTURE ARE 4 INCHES BELOW F.F.E. FOR FOR CONCRETE BLOCK AND 6 INCHES BELOW FOR WOOD FRAME STRUCTURES NEED TO IDENTIFY TYPE OF STRUCTURE AND ELEVATIONS IN ALL FOUR (4) CORNERS ** THE SUBJECT LOTS DRAINAGE MUST NOT NEGATIVELY IMPACT ANY ADJACENT PROPERTIES (RIGHT SIDE) _____________________________________________________________________________________________________________________ 6/1/2023 - PREVIOUS INSPECTION NOTES ** 06/01/23 NEED ELEVATION SHOTS ON ALL ADJACENT PROPERTY LINES AT 20 FOOT INTERVALS ** CHECK RIGHT SIDE NEED FINAL ELEVATION SHOTS ON A 20 FOOT GRID INSIDE PROPERTY LINE ** ELEVATIONS ON ALL ADJACENT PROPERTIES AT A MINIMUM OF 20 FOOT INTERVALS ON 10 FOOT OFF-SET OUTSIDE THE PROPERTY LINE ** F.F.E. SHOTS AND ALL OTHER HARD SHOTS NEED TO BE TO THE 100th ** ADJACENT DRIVEWAY CULVERTS AND DRAINAGE FEATURES: FINAL SURVEY MUST INCLUDE THE INVERTS OF ADJACENT DEVELOPED PROPERTY DRIVEWAY CULVERTAND ANY OTHER DRAINAGE FEATURE WITHIN 100 FEET OF THE PROPERTY LINES. ** SOD ELEVATIONS ADJACENT TO THE STRUCTURE ARE 4 INCHES BELOW F.F.E. FOR FOR CONCRETE BLOCK AND 6 INCHES BELOW FOR WOOD FRAME STRUCTURES NEED TO IDENTIFY TYPE OF STRUCTURE ** THE SUBJECT LOTS DRAINAGE MUST NOT NEGATIVELY IMPACT ANY ADJACENT PROPERTIES (RIGHT SIDE)
ROW- FINAL SURVEY/GRADING CERTIFICATION 08/03/2023 Disapproved -FEE REQUIRED EMADISON
Note: ** 08/03/23Drainage from the structure is to be a 6 inch (5%) minimum slope for the first 10’.(E) Elevations on all adjacent properties at a minimum of 20-foot intervals, on a 10 foot offset, outside the property lines. (A) Existing interior elevations on a 20’ grid. (E) ** 7/20/2023 - PREVIOUS INSPECTION NOTES ** 07/20/23 ** ADJACENT DRIVEWAY CULVERTS AND DRAINAGE FEATURES: FINAL SURVEY MUST INCLUDE THE INVERTS OF ADJACENT DEVELOPED PROPERTY DRIVEWAY CULVERTS AND ANY OTHER DRAINAGE FEATURE WITHIN 100 FEET OF THE PROPERTY LINES. 7/11/2023 - PREVIOUS INSPECTION NOTES ** 07/11/23 NEED TO READ ALL INSPECTOR NOTES FROM PREVIOUS (2) TWO FINAL SURVEY INSPECTIONS ** NEED TO SUBMIT A NEW FINAL SURVEY WITH ALL REQUIRED CORRECTIONS _______________________________________________________________________________________________________________________ 6/30/2023 - PREVIOUS INSPECTION NOTES 6/30/23=Drainage from the structure is to be a 6 inch (5%) minimum slope for the first 10’.(E) Elevations on all adjacent properties at a minimum of 20-foot intervals, on a 10 foot offset, outside the property lines. (A) Existing interior elevations on a 20’ grid. (E) The front property line/right away elevation are to be equal to or greater than the centerline of the road elevation. (I) NEED TO READ THE PREVIOUS NOTES AND SUBMIT A NEW FINAL SURVEY . ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 6/21/2023 - PREVIOUS INSPECTION NOTES ** 06/01/23 NEED ELEVATION SHOTS ON ALL ADJACENT PROPERTY LINES AT 20 FOOT INTERVALS AND ACROSS SUBJECT LOTS FRONT PROPERTY LINE TO DETERMINE IF EQUAL OR HIGHER THAN THE CENTERLINE OF ROAD ** NEED F.F.E. SHOTS ON ALL ADJACENT PROPERTIES SIDES AND REAR ** ELEVATIONS ON ALL ADJACENT PROPERTIES AT A MINIMUM OF 20 FOOT INTERVALS ON 10 FOOT OFF-SET OUTSIDE THE PROPERTY LINE (LEFT SIDE) ** F.F.E. SHOTS AND ALL OTHER HARD SHOTS NEED TO BE TO THE 100th ** ADJACENT DRIVEWAY CULVERTS AND DRAINAGE FEATURES: FINAL SURVEY MUST INCLUDE THE INVERTS OF ADJACENT DEVELOPED PROPERTY DRIVEWAY CULVERTS AND ANY OTHER DRAINAGE FEATURE WITHIN 100 FEET OF THE PROPERTY LINES. ** SOD ELEVATIONS ADJACENT TO THE STRUCTURE ARE 4 INCHES BELOW F.F.E. FOR FOR CONCRETE BLOCK AND 6 INCHES BELOW FOR WOOD FRAME STRUCTURES NEED TO IDENTIFY TYPE OF STRUCTURE AND ELEVATIONS IN ALL FOUR (4) CORNERS ** THE SUBJECT LOTS DRAINAGE MUST NOT NEGATIVELY IMPACT ANY ADJACENT PROPERTIES (RIGHT SIDE) _____________________________________________________________________________________________________________________ 6/1/2023 - PREVIOUS INSPECTION NOTES ** 06/01/23 NEED ELEVATION SHOTS ON ALL ADJACENT PROPERTY LINES AT 20 FOOT INTERVALS ** CHECK RIGHT SIDE NEED FINAL ELEVATION SHOTS ON A 20 FOOT GRID INSIDE PROPERTY LINE ** ELEVATIONS ON ALL ADJACENT PROPERTIES AT A MINIMUM OF 20 FOOT INTERVALS ON 10 FOOT OFF-SET OUTSIDE THE PROPERTY LINE ** F.F.E. SHOTS AND ALL OTHER HARD SHOTS NEED TO BE TO THE 100th ** ADJACENT DRIVEWAY CULVERTS AND DRAINAGE FEATURES: FINAL SURVEY MUST INCLUDE THE INVERTS OF ADJACENT DEVELOPED PROPERTY DRIVEWAY CULVERTAND ANY OTHER DRAINAGE FEATURE WITHIN 100 FEET OF THE PROPERTY LINES. ** SOD ELEVATIONS ADJACENT TO THE STRUCTURE ARE 4 INCHES BELOW F.F.E. FOR FOR CONCRETE BLOCK AND 6 INCHES BELOW FOR WOOD FRAME STRUCTURES NEED TO IDENTIFY TYPE OF STRUCTURE ** THE SUBJECT LOTS DRAINAGE MUST NOT NEGATIVELY IMPACT ANY ADJACENT PROPERTIES (RIGHT SIDE)
ROW- FINAL SURVEY/GRADING CERTIFICATION 07/20/2023 Disapproved -FEE REQUIRED EMADISON
Note: ** 07/20/23 ** ADJACENT DRIVEWAY CULVERTS AND DRAINAGE FEATURES: FINAL SURVEY MUST INCLUDE THE INVERTS OF ADJACENT DEVELOPED PROPERTY DRIVEWAY CULVERTS AND ANY OTHER DRAINAGE FEATURE WITHIN 100 FEET OF THE PROPERTY LINES. 7/11/2023 - PREVIOUS INSPECTION NOTES ** 07/11/23 NEED TO READ ALL INSPECTOR NOTES FROM PREVIOUS (2) TWO FINAL SURVEY INSPECTIONS ** NEED TO SUBMIT A NEW FINAL SURVEY WITH ALL REQUIRED CORRECTIONS _______________________________________________________________________________________________________________________ 6/30/2023 - PREVIOUS INSPECTION NOTES 6/30/23=Drainage from the structure is to be a 6 inch (5%) minimum slope for the first 10’.(E) Elevations on all adjacent properties at a minimum of 20-foot intervals, on a 10 foot offset, outside the property lines. (A) Existing interior elevations on a 20’ grid. (E) The front property line/right away elevation are to be equal to or greater than the centerline of the road elevation. (I) NEED TO READ THE PREVIOUS NOTES AND SUBMIT A NEW FINAL SURVEY . ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 6/21/2023 - PREVIOUS INSPECTION NOTES ** 06/01/23 NEED ELEVATION SHOTS ON ALL ADJACENT PROPERTY LINES AT 20 FOOT INTERVALS AND ACROSS SUBJECT LOTS FRONT PROPERTY LINE TO DETERMINE IF EQUAL OR HIGHER THAN THE CENTERLINE OF ROAD ** NEED F.F.E. SHOTS ON ALL ADJACENT PROPERTIES SIDES AND REAR ** ELEVATIONS ON ALL ADJACENT PROPERTIES AT A MINIMUM OF 20 FOOT INTERVALS ON 10 FOOT OFF-SET OUTSIDE THE PROPERTY LINE (LEFT SIDE) ** F.F.E. SHOTS AND ALL OTHER HARD SHOTS NEED TO BE TO THE 100th ** ADJACENT DRIVEWAY CULVERTS AND DRAINAGE FEATURES: FINAL SURVEY MUST INCLUDE THE INVERTS OF ADJACENT DEVELOPED PROPERTY DRIVEWAY CULVERTS AND ANY OTHER DRAINAGE FEATURE WITHIN 100 FEET OF THE PROPERTY LINES. ** SOD ELEVATIONS ADJACENT TO THE STRUCTURE ARE 4 INCHES BELOW F.F.E. FOR FOR CONCRETE BLOCK AND 6 INCHES BELOW FOR WOOD FRAME STRUCTURES NEED TO IDENTIFY TYPE OF STRUCTURE AND ELEVATIONS IN ALL FOUR (4) CORNERS ** THE SUBJECT LOTS DRAINAGE MUST NOT NEGATIVELY IMPACT ANY ADJACENT PROPERTIES (RIGHT SIDE) _____________________________________________________________________________________________________________________ 6/1/2023 - PREVIOUS INSPECTION NOTES ** 06/01/23 NEED ELEVATION SHOTS ON ALL ADJACENT PROPERTY LINES AT 20 FOOT INTERVALS ** CHECK RIGHT SIDE NEED FINAL ELEVATION SHOTS ON A 20 FOOT GRID INSIDE PROPERTY LINE ** ELEVATIONS ON ALL ADJACENT PROPERTIES AT A MINIMUM OF 20 FOOT INTERVALS ON 10 FOOT OFF-SET OUTSIDE THE PROPERTY LINE ** F.F.E. SHOTS AND ALL OTHER HARD SHOTS NEED TO BE TO THE 100th ** ADJACENT DRIVEWAY CULVERTS AND DRAINAGE FEATURES: FINAL SURVEY MUST INCLUDE THE INVERTS OF ADJACENT DEVELOPED PROPERTY DRIVEWAY CULVERTAND ANY OTHER DRAINAGE FEATURE WITHIN 100 FEET OF THE PROPERTY LINES. ** SOD ELEVATIONS ADJACENT TO THE STRUCTURE ARE 4 INCHES BELOW F.F.E. FOR FOR CONCRETE BLOCK AND 6 INCHES BELOW FOR WOOD FRAME STRUCTURES NEED TO IDENTIFY TYPE OF STRUCTURE ** THE SUBJECT LOTS DRAINAGE MUST NOT NEGATIVELY IMPACT ANY ADJACENT PROPERTIES (RIGHT SIDE)
ELECTRIC - EARLY POWER 07/20/2023 APPROVED - AS NOTED AGAETANO
Note: FPL notified at 10:29am
ELECTRIC - EARLY POWER 07/17/2023 CANCELLED BY APPLICANT WEB
ROW- FINAL SURVEY/GRADING CERTIFICATION 07/11/2023 Disapproved -FEE REQUIRED EMADISON
Note: ** 07/11/23 NEED TO READ ALL INSPECTOR NOTES FROM PREVIOUS (2) TWO FINAL SURVEY INSPECTIONS ** NEED TO SUBMIT A NEW FINAL SURVEY WITH ALL REQUIRED CORRECTIONS _______________________________________________________________________________________________________________________ 6/30/2023 - PREVIOUS INSPECTION NOTES 6/30/23=Drainage from the structure is to be a 6 inch (5%) minimum slope for the first 10’.(E) Elevations on all adjacent properties at a minimum of 20-foot intervals, on a 10 foot offset, outside the property lines. (A) Existing interior elevations on a 20’ grid. (E) The front property line/right away elevation are to be equal to or greater than the centerline of the road elevation. (I) NEED TO READ THE PREVIOUS NOTES AND SUBMIT A NEW FINAL SURVEY . ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 6/21/2023 - PREVIOUS INSPECTION NOTES ** 06/01/23 NEED ELEVATION SHOTS ON ALL ADJACENT PROPERTY LINES AT 20 FOOT INTERVALS AND ACROSS SUBJECT LOTS FRONT PROPERTY LINE TO DETERMINE IF EQUAL OR HIGHER THAN THE CENTERLINE OF ROAD ** NEED F.F.E. SHOTS ON ALL ADJACENT PROPERTIES SIDES AND REAR ** ELEVATIONS ON ALL ADJACENT PROPERTIES AT A MINIMUM OF 20 FOOT INTERVALS ON 10 FOOT OFF-SET OUTSIDE THE PROPERTY LINE (LEFT SIDE) ** F.F.E. SHOTS AND ALL OTHER HARD SHOTS NEED TO BE TO THE 100th ** ADJACENT DRIVEWAY CULVERTS AND DRAINAGE FEATURES: FINAL SURVEY MUST INCLUDE THE INVERTS OF ADJACENT DEVELOPED PROPERTY DRIVEWAY CULVERTS AND ANY OTHER DRAINAGE FEATURE WITHIN 100 FEET OF THE PROPERTY LINES. ** SOD ELEVATIONS ADJACENT TO THE STRUCTURE ARE 4 INCHES BELOW F.F.E. FOR FOR CONCRETE BLOCK AND 6 INCHES BELOW FOR WOOD FRAME STRUCTURES NEED TO IDENTIFY TYPE OF STRUCTURE AND ELEVATIONS IN ALL FOUR (4) CORNERS ** THE SUBJECT LOTS DRAINAGE MUST NOT NEGATIVELY IMPACT ANY ADJACENT PROPERTIES (RIGHT SIDE) _____________________________________________________________________________________________________________________ 6/1/2023 - PREVIOUS INSPECTION NOTES ** 06/01/23 NEED ELEVATION SHOTS ON ALL ADJACENT PROPERTY LINES AT 20 FOOT INTERVALS ** CHECK RIGHT SIDE NEED FINAL ELEVATION SHOTS ON A 20 FOOT GRID INSIDE PROPERTY LINE ** ELEVATIONS ON ALL ADJACENT PROPERTIES AT A MINIMUM OF 20 FOOT INTERVALS ON 10 FOOT OFF-SET OUTSIDE THE PROPERTY LINE ** F.F.E. SHOTS AND ALL OTHER HARD SHOTS NEED TO BE TO THE 100th ** ADJACENT DRIVEWAY CULVERTS AND DRAINAGE FEATURES: FINAL SURVEY MUST INCLUDE THE INVERTS OF ADJACENT DEVELOPED PROPERTY DRIVEWAY CULVERTAND ANY OTHER DRAINAGE FEATURE WITHIN 100 FEET OF THE PROPERTY LINES. ** SOD ELEVATIONS ADJACENT TO THE STRUCTURE ARE 4 INCHES BELOW F.F.E. FOR FOR CONCRETE BLOCK AND 6 INCHES BELOW FOR WOOD FRAME STRUCTURES NEED TO IDENTIFY TYPE OF STRUCTURE ** THE SUBJECT LOTS DRAINAGE MUST NOT NEGATIVELY IMPACT ANY ADJACENT PROPERTIES (RIGHT SIDE)
ROW FIELD SURVEY /GRADING CERTIFICATION 07/10/2023 Disapproved - NO FEE EMADISON
Note: ** 07/10/23 FINAL SURVEY MUST BE COMPLETED AND APPROVED BEFORE THE FIELD SURVEY CAN BE SCHEDULED _________________________________________________________________________________________________________________________ 6/1/2023 - PREVIOUS INSPECTION NOTES ** 06/01/23 FINAL SURVEY MUST BE APPROVED BEFORE A FIELD SURVEY INSPECTION CAN BE DONE INSPECTOR WILL CREATE THE FIELD SURVEY ONCE HE APPROVES THE FINAL SURVEY
ROW- FINAL SURVEY/GRADING CERTIFICATION 06/30/2023 Disapproved - NO FEE GBERTOLA
Note: 6/30/23=Drainage from the structure is to be a 6 inch (5%) minimum slope for the first 10’.(E) Elevations on all adjacent properties at a minimum of 20-foot intervals, on a 10 foot offset, outside the property lines. (A) Existing interior elevations on a 20’ grid. (E) The front property line/right away elevation are to be equal to or greater than the centerline of the road elevation. (I) NEED TO READ THE PREVIOUS NOTES AND SUBMIT A NEW FINAL SURVEY . ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 6/21/2023 - PREVIOUS INSPECTION NOTES ** 06/01/23 NEED ELEVATION SHOTS ON ALL ADJACENT PROPERTY LINES AT 20 FOOT INTERVALS AND ACROSS SUBJECT LOTS FRONT PROPERTY LINE TO DETERMINE IF EQUAL OR HIGHER THAN THE CENTERLINE OF ROAD ** NEED F.F.E. SHOTS ON ALL ADJACENT PROPERTIES SIDES AND REAR ** ELEVATIONS ON ALL ADJACENT PROPERTIES AT A MINIMUM OF 20 FOOT INTERVALS ON 10 FOOT OFF-SET OUTSIDE THE PROPERTY LINE (LEFT SIDE) ** F.F.E. SHOTS AND ALL OTHER HARD SHOTS NEED TO BE TO THE 100th ** ADJACENT DRIVEWAY CULVERTS AND DRAINAGE FEATURES: FINAL SURVEY MUST INCLUDE THE INVERTS OF ADJACENT DEVELOPED PROPERTY DRIVEWAY CULVERTS AND ANY OTHER DRAINAGE FEATURE WITHIN 100 FEET OF THE PROPERTY LINES. ** SOD ELEVATIONS ADJACENT TO THE STRUCTURE ARE 4 INCHES BELOW F.F.E. FOR FOR CONCRETE BLOCK AND 6 INCHES BELOW FOR WOOD FRAME STRUCTURES NEED TO IDENTIFY TYPE OF STRUCTURE AND ELEVATIONS IN ALL FOUR (4) CORNERS ** THE SUBJECT LOTS DRAINAGE MUST NOT NEGATIVELY IMPACT ANY ADJACENT PROPERTIES (RIGHT SIDE) _____________________________________________________________________________________________________________________ 6/1/2023 - PREVIOUS INSPECTION NOTES ** 06/01/23 NEED ELEVATION SHOTS ON ALL ADJACENT PROPERTY LINES AT 20 FOOT INTERVALS ** CHECK RIGHT SIDE NEED FINAL ELEVATION SHOTS ON A 20 FOOT GRID INSIDE PROPERTY LINE ** ELEVATIONS ON ALL ADJACENT PROPERTIES AT A MINIMUM OF 20 FOOT INTERVALS ON 10 FOOT OFF-SET OUTSIDE THE PROPERTY LINE ** F.F.E. SHOTS AND ALL OTHER HARD SHOTS NEED TO BE TO THE 100th ** ADJACENT DRIVEWAY CULVERTS AND DRAINAGE FEATURES: FINAL SURVEY MUST INCLUDE THE INVERTS OF ADJACENT DEVELOPED PROPERTY DRIVEWAY CULVERTAND ANY OTHER DRAINAGE FEATURE WITHIN 100 FEET OF THE PROPERTY LINES. ** SOD ELEVATIONS ADJACENT TO THE STRUCTURE ARE 4 INCHES BELOW F.F.E. FOR FOR CONCRETE BLOCK AND 6 INCHES BELOW FOR WOOD FRAME STRUCTURES NEED TO IDENTIFY TYPE OF STRUCTURE ** THE SUBJECT LOTS DRAINAGE MUST NOT NEGATIVELY IMPACT ANY ADJACENT PROPERTIES (RIGHT SIDE)
ROW- FINAL SURVEY/GRADING CERTIFICATION 06/21/2023 Disapproved -FEE REQUIRED EMADISON
Note: ** 06/01/23 NEED ELEVATION SHOTS ON ALL ADJACENT PROPERTY LINES AT 20 FOOT INTERVALS AND ACROSS SUBJECT LOTS FRONT PROPERTY LINE TO DETERMINE IF EQUAL OR HIGHER THAN THE CENTERLINE OF ROAD ** NEED F.F.E. SHOTS ON ALL ADJACENT PROPERTIES SIDES AND REAR ** ELEVATIONS ON ALL ADJACENT PROPERTIES AT A MINIMUM OF 20 FOOT INTERVALS ON 10 FOOT OFF-SET OUTSIDE THE PROPERTY LINE (LEFT SIDE) ** F.F.E. SHOTS AND ALL OTHER HARD SHOTS NEED TO BE TO THE 100th ** ADJACENT DRIVEWAY CULVERTS AND DRAINAGE FEATURES: FINAL SURVEY MUST INCLUDE THE INVERTS OF ADJACENT DEVELOPED PROPERTY DRIVEWAY CULVERTS AND ANY OTHER DRAINAGE FEATURE WITHIN 100 FEET OF THE PROPERTY LINES. ** SOD ELEVATIONS ADJACENT TO THE STRUCTURE ARE 4 INCHES BELOW F.F.E. FOR FOR CONCRETE BLOCK AND 6 INCHES BELOW FOR WOOD FRAME STRUCTURES NEED TO IDENTIFY TYPE OF STRUCTURE AND ELEVATIONS IN ALL FOUR (4) CORNERS ** THE SUBJECT LOTS DRAINAGE MUST NOT NEGATIVELY IMPACT ANY ADJACENT PROPERTIES (RIGHT SIDE) _____________________________________________________________________________________________________________________ 6/1/2023 - PREVIOUS INSPECTION NOTES ** 06/01/23 NEED ELEVATION SHOTS ON ALL ADJACENT PROPERTY LINES AT 20 FOOT INTERVALS ** CHECK RIGHT SIDE NEED FINAL ELEVATION SHOTS ON A 20 FOOT GRID INSIDE PROPERTY LINE ** ELEVATIONS ON ALL ADJACENT PROPERTIES AT A MINIMUM OF 20 FOOT INTERVALS ON 10 FOOT OFF-SET OUTSIDE THE PROPERTY LINE ** F.F.E. SHOTS AND ALL OTHER HARD SHOTS NEED TO BE TO THE 100th ** ADJACENT DRIVEWAY CULVERTS AND DRAINAGE FEATURES: FINAL SURVEY MUST INCLUDE THE INVERTS OF ADJACENT DEVELOPED PROPERTY DRIVEWAY CULVERTAND ANY OTHER DRAINAGE FEATURE WITHIN 100 FEET OF THE PROPERTY LINES. ** SOD ELEVATIONS ADJACENT TO THE STRUCTURE ARE 4 INCHES BELOW F.F.E. FOR FOR CONCRETE BLOCK AND 6 INCHES BELOW FOR WOOD FRAME STRUCTURES NEED TO IDENTIFY TYPE OF STRUCTURE ** THE SUBJECT LOTS DRAINAGE MUST NOT NEGATIVELY IMPACT ANY ADJACENT PROPERTIES (RIGHT SIDE)
ROW- FINAL SURVEY/GRADING CERTIFICATION 06/01/2023 Disapproved - NO FEE EMADISON
Note: ** 06/01/23 NEED ELEVATION SHOTS ON ALL ADJACENT PROPERTY LINES AT 20 FOOT INTERVALS ** CHECK RIGHT SIDE NEED FINAL ELEVATION SHOTS ON A 20 FOOT GRID INSIDE PROPERTY LINE ** ELEVATIONS ON ALL ADJACENT PROPERTIES AT A MINIMUM OF 20 FOOT INTERVALS ON 10 FOOT OFF-SET OUTSIDE THE PROPERTY LINE ** F.F.E. SHOTS AND ALL OTHER HARD SHOTS NEED TO BE TO THE 100th ** ADJACENT DRIVEWAY CULVERTS AND DRAINAGE FEATURES: FINAL SURVEY MUST INCLUDE THE INVERTS OF ADJACENT DEVELOPED PROPERTY DRIVEWAY CULVERTAND ANY OTHER DRAINAGE FEATURE WITHIN 100 FEET OF THE PROPERTY LINES. ** SOS ELEVATIONS ADJACENT TO THE STRUCTURE ARE 4 INCHES BELOW F.F.E. FOR FOR CONCRETE BLOCK AND 6 INCHES BELOW FOR WOOD FRAME STRUCTURES NEED TO IDENTIFY TYPE OF STRUCTURE ** THE SUBJECT LOTS DRAINAGE MUST NOT NEGATIVELY IMPACT ANY ADJACENT PROPERTIES (RIGHT SIDE)
ROW FIELD SURVEY /GRADING CERTIFICATION 06/01/2023 Disapproved - NO FEE EMADISON
Note: ** 06/01/23 FINAL SURVEY MUST BE APPROVED BEFORE A FIELD SURVEY INSPECTION CAN BE DONE INSPECTOR WILL CREATE THE FIELD SURVEY ONCE HE APPROVES THE FINAL SURVEY
ROW- PRE-APRON (PRE-POUR) 03/02/2023 APPROVED PFLANAGAN
Note: IT'S THE CONTRACTORS RESPONSIBILITY TO CHECK THE CULVERT PIPE ELEVATIONS BEFORE POURING CONCRETE FOR DRIVEWAY.
LATH/BRICK/ WATER BARRIER 02/13/2023 APPROVED - AS NOTED AGAETANO
Note: 02-13-2023 R319.1 Address identification. Buildings shall be provided with approved address identification. The address identification shall be legible and placed in a position that is visiblen from the street or road fronting the property. Address identification characters shall contrast with their background. Address numbers shall be Arabic numbers or alphabetical letters. Numbers shall not be spelled out. Each character shall be not less than 4 inches (102 mm) in height with a stroke width of not less than 0.5 inch (12.7 mm). Where required by the fire code official, address identification shall be provided in additional approved locations to facilitate emergency response. Where access is by means of a private road and the building address cannot be viewed from the public way, a monument, pole or other sign or means shall be used to identify the structure. Address identification shall be maintained.
GRAVITY SEWER TEST 01/26/2023 APPROVED MGIBSON
U - SEWER TIE IN 01/26/2023 APPROVED MGIBSON
PEP TANK INSTALLATION REQUEST 01/26/2023 APPROVED - AS NOTED TSCHWEERS
Note: 1/26/2023 Gravity Sewer no pep tanks needed.
INSULATION 01/20/2023 APPROVED AGAETANO
ALL ROUGH 01/13/2023 APPROVED AGAETANO
Note: 1/11/2023 - PREVIOUS INSPECTION NOTES 01-11-2023 1. Mechanical drawings not on site.NEED THE APPROVED DOCUMENTS ON SITE FOR INSPECTION 107.3,1. 2. ADDRESS MUST BE POSTED AND PLAINLY VISIBLE TO INSPECTORS. IF ADDRESS IS NOT PLAINLY VISIBLE, INSPECTORS WILL NOT PERFORM INSPECTIONS AND A REINSPECTION FEE WILL BE ISSUED. Florida Building Code-Building Section 501.2. R319.1 Residential R319.1 Address identification. Buildings shall be provided with approved address identification. The address identification shall be legible and placed in a position that is visible from the street or road fronting the property. Address identification characters shall contrast with their background. Address numbers shall be Arabic numbers or alphabetical letters. Numbers shall not be spelled out. Each character shall be not less than 4 inches (102 mm) in height with a stroke width of not less than 0.5 inch (12.7 mm). Where required by the fire code official, address identification shall be provided in additional approved locations to facilitate emergency response. Where access is by means of a private road and the building address cannot be viewed from the public way, a monument, pole or other sign or means shall be used to identify the structure. Address identification shall be maintained. 3. 5' head pressure test failed P2503.5.1
ALL ROUGH 01/11/2023 Disapproved - NO FEE AGAETANO
Note: 01-11-2023 1. Mechanical drawings not on site.NEED THE APPROVED DOCUMENTS ON SITE FOR INSPECTION 107.3,1. 2. ADDRESS MUST BE POSTED AND PLAINLY VISIBLE TO INSPECTORS. IF ADDRESS IS NOT PLAINLY VISIBLE, INSPECTORS WILL NOT PERFORM INSPECTIONS AND A REINSPECTION FEE WILL BE ISSUED. Florida Building Code-Building Section 501.2. R319.1 Residential R319.1 Address identification. Buildings shall be provided with approved address identification. The address identification shall be legible and placed in a position that is visible from the street or road fronting the property. Address identification characters shall contrast with their background. Address numbers shall be Arabic numbers or alphabetical letters. Numbers shall not be spelled out. Each character shall be not less than 4 inches (102 mm) in height with a stroke width of not less than 0.5 inch (12.7 mm). Where required by the fire code official, address identification shall be provided in additional approved locations to facilitate emergency response. Where access is by means of a private road and the building address cannot be viewed from the public way, a monument, pole or other sign or means shall be used to identify the structure. Address identification shall be maintained. 3. 5' head pressure test failed P2503.5.1
ROOF SHEATHING / BRACES/TIES/DOWN CELL 12/19/2022 APPROVED AGAETANO
Note: 12/1/2022 - PREVIOUS INSPECTION NOTES New inspection due to canceled inspection Inspector Notes from Inspection 2450 Note: Truss A-11 has tail broken off, blocking was added, but strap has no nails into truss or blocking, will need truss engineer to approve this repair before Braces/ Tie Downs Inspection 12-01-2022 Manufacturer's specs at Replace Broken Overhang not installed as per specs.Truss A11
ROOF SHEATHING / BRACES/TIES/DOWN CELL 12/01/2022 Disapproved -FEE REQUIRED AGAETANO
Note: New inspection due to canceled inspection Inspector Notes from Inspection 2450 Note: Truss A-11 has tail broken off, blocking was added, but strap has no nails into truss or blocking, will need truss engineer to approve this repair before Braces/ Tie Downs Inspection 12-01-2022 Manufacturer's specs at Replace Broken Overhang not installed as per specs.Truss A11
ROOF SHEATHING / BRACES/TIES/DOWN CELL 11/14/2022 CANCELLED BY APPLICANT WEB
Note: Inspector Notes from Inspection 2450 Note: Truss A-11 has tail broken off, blocking was added, but strap has no nails into truss or blocking, will need truss engineer to approve this repair before Braces/ Tie Downs Inspection
WALL SHEATHING 10/26/2022 APPROVED - AS NOTED DCUSHING
Note: Note: Truss A-11 has tail broken off, blocking was added, but strap has no nails into truss or blocking, will need truss engineer to approve this repair before Braces/ Tie Downs Inspection
ROOF SHEATHING / BRACES/TIES/DOWN CELL 10/26/2022 Disapproved - NO FEE AGAETANO
Note: 10-26-2022 NEED THE APPROVED DOCUMENTS ON SITE FOR INSPECTION 107.3,1. Contractor on site.
ROOF SHEATHING / BRACES/TIES/DOWN CELL 10/26/2022 Disapproved -FEE REQUIRED AGAETANO
Note: 10/26/2022 - PREVIOUS INSPECTION NOTES 10-26-2022 NEED THE APPROVED DOCUMENTS ON SITE FOR INSPECTION 107.3,1. Contractor on site. 10-26-2022 Inspector went back. Contractor has Approved Drawings on site. 1. A 24 truss in the back has a P.T. 2 x added over thhe truss and under the strap. Please providde engineering. 2. Lanai truss left of column strap is not fastened completely. 3. S3 Bearing wall calls for SP2 every 16" OC. Please install as per plan. 4. S3 Permanent Gable bracing not installed as per plans. 5. Truss layout not on site. 6. S3.1 Wall support post straps not installed as per plans. Inspection stopped.
ROOF VALLEY & METAL 10/26/2022 APPROVED - AS NOTED DCUSHING
Note: Note: Truss A-11 has tail broken off, blocking was added, but strap has no nails into truss or blocking, will need truss engineer to approve this repair before Braces/ Tie Downs Inspection
U-CROSS CONNECTION 10/26/2022 APPROVED DHANEY
TIE BEAM / LINTEL 10/25/2022 APPROVED AGAETANO
Note: 10/21/2022 - PREVIOUS INSPECTION NOTES Inspector Notes from Inspection 2250 THIS IS A REINSPECTION Soil has collapsed in the front left area of footing. Soil collapsed into footing. Remove soil to maintain 3" clearance of rebar. 08-26-2022 - Remove soil to maintain 3" clearance of rebar. Superintendent on site and will remove soil. 10-21-2022 Dowels have been fille and the home has trusses installed and dried in. Please schedule an Xray inspection with the building department for the tie beam inspection or provide engineering that the work has been done correctly.
TIE BEAM / LINTEL 10/21/2022 Disapproved -FEE REQUIRED AGAETANO
Note: Inspector Notes from Inspection 2250 THIS IS A REINSPECTION Soil has collapsed in the front left area of footing. Soil collapsed into footing. Remove soil to maintain 3" clearance of rebar. 08-26-2022 - Remove soil to maintain 3" clearance of rebar. Superintendent on site and will remove soil. 10-21-2022 Dowels have been fille and the home has trusses installed and dried in. Please schedule an Xray inspection with the building department for the tie beam inspection or provide engineering that the work has been done correctly.
FOUND SURVEY APPROVED (OFFICE) 09/15/2022 APPROVED TBAKER
MONOLITHIC SLAB 08/26/2022 APPROVED - AS NOTED AGAETANO
Note: THIS IS A REINSPECTION Soil has collapsed in the front left area of footing. Soil collapsed into footing. Remove soil to maintain 3" clearance of rebar. 08-26-2022 - Remove soil to maintain 3" clearance of rebar. Superintendent on site and will remove soil.
MONOLITHIC SLAB 08/25/2022 Disapproved - NO FEE AGAETANO
Note: Soil has collapsed in the front left area of footing. Soil collapsed into footing. Remove soil to maintain 3" clearance of rebar.
ROW - DRAINAGE 08/19/2022 APPROVED EMADISON
Note: THIS IS A REINSPECTION ** 08/19/22 CORRECT5IONS MADE EVERYTHING LOOKS GOOD AT THIS TIME THIS IS A REINSPECTION ** 08/18/22 TEMPORARY PIPE IS CRUSHED AND CLOGGED NEED TO FIX TO KEEP THE SWALE OPEN ALLOWING THE STORMWATER TO FLOW. ** FOLLOW UP INSPECTION ON 08/19/22 NEED TO KEEP SWALE CLEAR THROUGH OUT CONSTRUCTION PROJECT OR PUT A TEMP. PIPE MINIMUM OF 12" TO ALLOW WATER TO FLOW THROUGH LOT NEXT INSPECTION 8/18/22
ROW - DRAINAGE 08/18/2022 Disapproved -FEE REQUIRED EMADISON
Note: THIS IS A REINSPECTION ** 08/18/22 TEMPORARY PIPE IS CRUSHED AND CLOGGED NEED TO FIX TO KEEP THE SWALE OPEN ALLOWING THE STORMWATER TO FLOW. ** FOLLOW UP INSPECTION ON 08/19/22 NEED TO KEEP SWALE CLEAR THROUGH OUT CONSTRUCTION PROJECT OR PUT A TEMP. PIPE MINIMUM OF 12" TO ALLOW WATER TO FLOW THROUGH LOT NEXT INSPECTION 8/18/22
PLUMBING 1ST ROUGH UNDERGROUND 08/17/2022 APPROVED MGIBSON
ROW - DRAINAGE 08/12/2022 Disapproved - NO FEE PFLANAGAN
Note: NEED TO KEEP SWALE CLEAR THROUGH OUT CONSTRUCTION PROJECT OR PUT A TEMP. PIPE MINIMUM OF 12" TO ALLOW WATER TO FLOW THROUGH LOT NEXT INSPECTION 8/18/22
WATER METER INSTALLATION REQUEST 07/28/2022 APPROVED CSTONE

Review History

Department Status Date In Date Out
MECH COMPLETE 09/15/2023 09/15/2023
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
BADMIN INFORMATION 08/07/2023 08/07/2023
Note: Marked INFORMATION By: BARBIE BEMBRY - (386)986-3780 - BUILDINGDIVISION@PALMCOASTGOV.COM Please remove the street address from the beginning of your file names (See document submittal requirements on the website)
BADMIN INFORMATION 07/26/2023 07/26/2023
Note: Marked INFORMATION By: MICHELLE RAMOS - - MRAMOS@PALMCOASTGOV.COM Unable to process final survey. NOC Expired. Once updated NOC is uploaded, please resubmit final survey.
BADMIN INFORMATION 07/09/2023 07/09/2023
Note: Marked INFORMATION By: LIBBY MUSGROVE - - LMUSGROVE@PALMCOASTGOV.COM Wrong File Name Uploaded file name was not correct - Example: Site plan=site plan (do not add anything to the file names like numbers.)
BLD COMPLETE 12/16/2022 12/16/2022
Note: Released By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM
BLD COMPLETE 11/08/2022 11/09/2022
Note: Released By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM
BLD HOLD 10/25/2022 10/25/2022
Note: Held By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM All comments below per the 2020 Florida Building Code PLAN REVIEW COMMENTS: 1. X-Ray inspection will be required to verify the required rebar was installed.
ENGIN1 COMPLETE 09/15/2022 09/15/2022
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
ZON COMPLETE 09/15/2022 09/15/2022
Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM
BLD COMPLETE 07/27/2022 07/27/2022
Note: Released By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM
ENGIN1 COMPLETE 07/27/2022 07/27/2022
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
SW1 COMPLETE 07/27/2022 07/27/2022
Note: Released By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM
ZON COMPLETE 07/27/2022 07/28/2022
Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM
BADMIN INFORMATION 07/26/2022 07/26/2022
Note: Marked INFORMATION By: SCOTT THOMAS - - STHOMAS@PALMCOASTGOV.COM NOC MUST ADDRESS IN 'DESCRIPTION OF PROPERTY', NOT 'LAND' MUST RE-RECORD NOC WITH DIFFERENT INSTRUMENT # (2022038614)
BLD HOLD 07/26/2022 07/26/2022
Note: Held By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM All comments below per the 2020 Florida Building Code PLAN REVIEW COMMENTS: 1. Architects plan calls-out two different Simpson straps. Truss A01 exceeds the limit of the strap called-out. Revise truss layout for a strap that meets the required uplift design.
BLD HOLD 07/25/2022 07/25/2022
Note: Held By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM All comments below per the 2020 Florida Building Code PLAN REVIEW COMMENTS: 1. Provide which Simpson tie will be required for truss A01.
ENGIN1 COMPLETE 06/24/2022 06/24/2022
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
ZON COMPLETE 06/24/2022 06/24/2022
Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM
SW1 COMPLETE 06/24/2022 06/27/2022
Note: Released By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM
SW1 HOLD 06/23/2022 06/24/2022
Note: Held By: CONRAD TROHA - (386)986-4767 - CTROHA@PALMCOASTGOV.COM upload correct site plan
ENGIN1 HOLD 06/23/2022 06/24/2022
Note: Held By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM The revised site plan submitted is for a different address.
ZON HOLD 06/23/2022 06/24/2022
Note: Held By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM Incorrect site plan submitted.
ZON COMPLETE 06/15/2022 06/16/2022
Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM
SW1 HOLD 06/15/2022 06/21/2022
Note: Held By: EDWARD MADISON - - EMADISON@PALMCOASTGOV.COM must show all proposed and existing elevations as well ass FFE and property line elevations on adjacent properties.
BADMIN INFORMATION 06/15/2022 06/15/2022
Note: Marked INFORMATION By: MICHELLE RAMOS - - MRAMOS@PALMCOASTGOV.COM Please remove address from file name. Example final survey = final survey
ENGIN1 COMPLETE 06/15/2022 06/16/2022
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
ZON HOLD 06/01/2022 06/01/2022
Note: Held By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM pplease include the actual flood zone designation on the site plan. (Flood Zone X) this should be after map panel number and needs to be on all siteplans submitted.
SW1 HOLD 06/01/2022 06/13/2022
Note: Held By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM NEED TO HAVE PROPOSED ELEVATIONS AT RIGHT OF WAY LINE IN THE FRONT SO WE CAN DETERMIND IF IT IS HIGHER OR EQUAL TO SENTERLINE OF ROAD AND NEED TO HAVE ELEVATIONS FOR CENTERLINE OF ROAD RIGHT NOW YOU ONLY HAVE EP
ENGIN1 COMPLETE 06/01/2022 06/01/2022
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
ZON HOLD 05/19/2022 05/19/2022
Note: Held By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM repeat comment: Must include plat recording information to include map book and page number. map book and page missing please include the zoning
SW1 HOLD 05/19/2022 05/25/2022
Note: Held By: GABRIEL BERTOLA - (386)225-3840 - GBERTOLA@PALMCOASTGOV.COM See uploaded Stormwater checklist in attachments for correction. Make corrections on all unchecked items.
ENGIN1 COMPLETE 05/19/2022 05/19/2022
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
ELEC COMPLETE 05/08/2022 05/09/2022
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
MECH COMPLETE 05/08/2022 05/09/2022
Note: Released By: CHRIS PISCITELLI - (386)986-3782 - CPISCITELLI@PALMCOASTGOV.COM
BLD COMPLETE 05/08/2022 05/09/2022
Note: Released By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM
ZON HOLD 05/08/2022 05/09/2022
Note: Held By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM Very hard to see house layout due to all the hatched lines and information on plan, Must show driveway proposed material being used, All platted easements must be shown on site plan, Site plan and survey: Must include flood map panel number along with flood zone Must include plat recording information to include map book and page number. Color Sheet: Must state that the siding and body paint color will match. Please note that in the material section. If you will be installing a paver driveway, a right of way utilization agreement must be signed by all property owners and notarized and original will need to be turned in to us once electronic copy has been approved.
SW1 HOLD 05/08/2022 05/13/2022
Note: Held By: EDWARD MADISON - - EMADISON@PALMCOASTGOV.COM see SW1 CHECKLIST FOR ALL CORRECTIONS NEEDED ON SITE PLAN
ENGIN1 COMPLETE 05/08/2022 05/09/2022
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
BLD HOLD 04/28/2022 05/02/2022
Note: Held By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM All comments below per the 2020 Florida Building Code REVIEW COMMENTS: 1. Provide minimum roof sheathing thickness per Table R803.2.2
CUSVC COMPLETE 04/28/2022 05/03/2022
Note: Released By: HALEIGH HAND - -
ELEC HOLD 04/28/2022 04/28/2022
Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM Submit electric load calcs
ENGIN1 COMPLETE 04/28/2022 04/28/2022
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
LOCATE COMPLETE 04/28/2022 05/02/2022
Note: Released By: TONI CHURCHILL - -
MECH HOLD 04/28/2022 04/28/2022
Note: Held By: CHRIS PISCITELLI - (386)986-3782 - CPISCITELLI@PALMCOASTGOV.COM Energy Calcs need to be signed by the builder per 107.1 FBC 2020 7Th edition
SW1 HOLD 04/28/2022 05/05/2022
Note: Held By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM PLEASE SEE THE SW1 CHECKLIST FOR ALL REQUIREMENTS FOR SITE PLAN
ZON HOLD 04/28/2022 05/04/2022
Note: Held By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM Site plan: Very hard to see house layout due to all the hatched lines and information on plan, Must show driveway and walkway width and proposed material being used, Setbacks must be from the closest point of proposed improvements to property line. Front setback should be from the front porch, All platted easements must be shown on site plan, Site plan and survey: Must include flood map panel number along with flood zone Must include plat recording information to include map book and page number. Color Sheet: Must state that the siding and body paint color will match. Please note that in the material section. If you will be installing a paver driveway, a right of way utilization agreement must be signed by all property owners and notarized and original will need to be turned in to us once electronic copy has been approved.
SWALE COMPLETE 04/28/2022 06/27/2022
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
PLAN REVIEW - REVISION ¤32.50 09/18/2023
PLAN REVIEW - REVISION ¤32.50 09/18/2023
PLAN REVIEW - REVISION ¤32.50 09/18/2023
REINSPECTION RESIDENTIAL ¤40.00 09/18/2023
REINSPECTION RESIDENTIAL ¤40.00 09/18/2023
REINSPECTION RESIDENTIAL ¤40.00 09/18/2023
CONTRACTOR CHANGE ¤20.00 09/18/2023
SW ENG REINSPECTION 20 ¤20.00 09/18/2023
SW ENG - INSPECTION 20 ¤20.00 09/18/2023
SW ENG - INSPECTION 20 ¤20.00 09/18/2023
SW ENG - INSPECTION 20 ¤20.00 09/18/2023
SW ENG INSPECTION 80 ¤80.00 06/28/2022
SW ENG PRE APRON ¤30.00 06/28/2022
SW ENG - REVIEW 20 ¤20.00 06/28/2022
SW ENG RES REVIEW 200 ¤200.00 06/28/2022
3% TRANS IMPACT FEE CREDIT (¤52.92) 06/28/2022
SEWER INSPECTION ¤25.00 06/28/2022
SEWER CAPITAL FACILITY ¤4,939.76 06/28/2022
WATER CAPITAL FACILITY FEE ¤3,626.50 06/28/2022
SITE PLAN 30 ¤30.00 06/28/2022
3% FIRE IMPACT FEE CREDIT (¤11.66) 06/28/2022
IMPACT FEE FIRE ¤388.65 06/28/2022
IMPACT FEE PARKS ¤1,455.13 06/28/2022
IMPACT FEE SCHOOL ¤3,600.00 06/28/2022
IMPACT FEE TRANSPORTATION ¤1,764.00 06/28/2022
WATER -IRRIGATION INSPECTION ¤25.00 06/28/2022
3% PARKS IMPACT FEE CREDIT (¤43.65) 06/28/2022
SURCHARGE FS 533.721 ¤8.74 06/28/2022
SURCHARGE - FS 468.631 ¤13.11 06/28/2022
SW ENG - FOUNDATION SURVEY ¤20.00 06/28/2022
CONNECTION FEES ¤1,077.88 06/28/2022
WATER- TURN ON ¤25.00 06/28/2022
ADMINISTRATIVE RESIDENTIAL ¤30.00 06/28/2022
INSPECTION - RESIDENTIAL ¤792.00 06/28/2022
PLAN REVIEW - RESIDENTIAL ¤224.64 06/28/2022
Fees Total Due: ¤0.00 Total Paid: ¤18,584.68