Permit #2022050797
Permit Details
Status: FINAL
| Parcel Id: 07-11-31-7029-00610-0100 |
| CONDITIONED SPACE: 2956 sqft |
| GARAGE: 888 sqft |
| OPENED PORCH (WITH ROOF) : 140 sqft |
| OPENED PORCH (WITH ROOF) : 130 sqft |
| Total Square Footage: 4114 sqft |
| Block: 00610 |
| Subdivision: 2209 - SECTION 29-ROYAL PALMS |
| Job Phone: 386-237-5837 |
| Location Address: 19 RYALL LN |
| Type: DU - DUPLEX |
| Issue Date: 06/23/2022 |
| NOC: RECORDED |
| Applicant name: MARSEL GILMANSHIN |
| Owner: GILMANS DEVELOPMENT CORP |
|
Address 4873 PALM COAST PKW NW STE 4 PALM COAST, FL 32137 |
| Lot: 0100 |
| Contracted Stated Job Value: ¤350,000.00 |
| Job Description: Duplex |
| Type: CN |
Contractor
GILMANS DEVELOPMENT CORP
| Status | Location Address | State License Number | Phone |
| ACTIVE |
4873 PALM COAST PARKWAY NW #4 PALM COAST, FL 32137 |
CBC1263180 (Exp: 08/31/2026) | 386-237-5837 |
Sub Contractors
MAXIM BUDNIK
| Status | Location Address | State License Number | Phone |
| ACTIVE |
9788 HALSEY RD JACKSONVILLE, FL 32246 |
EC13007415 (Exp: 08/31/2026) | 904-509-7306 |
MAXIM BUDNIK
| Status | Location Address | State License Number |
| ACTIVE |
3 WAVECREST PL PALM COAST, FL 32164 |
CAC1818445 (Exp: 08/31/2026) |
OLEG BELINSKIY
| Status | Location Address | State License Number | Phone |
| ACTIVE |
19 PINE CIRCLE DRIVE19 PALM COAST, FL 32167 |
CCC1325974 (Exp: 08/31/2026) | 386-263-7906 |
GARY S WELBORN
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
1709 North Nova Road Holly Hill, 32117 |
CFC1426839 (Exp: 08/31/2026) | (386) 257-1172 | 386-252-5979 |
Inspection History
| Type | Request Date | Result | Inspector |
| BLD - BUILDING FINAL | 10/28/2024 | APPROVED | CVANSTRAHLEN |
| ROW - FINAL INSPECTION | 10/28/2024 | APPROVED | TPOLACEK |
| Note: AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED. | |||
| U -UTILITY RESIDENTIAL FINAL | 10/28/2024 | Disapproved -FEE REQUIRED | LFITZGERALD |
| Note: *** NOTES ADDED BY LFITZGERALD 10/28/2024 1:38:02 PM *** both pep tanks require dedicated 20 amp breaker/pep pumps not working correctly/1 tank has pipe disdged-utility-Ivan infrmed-sendig tech out to repair Inspector Notes from Inspection 9035 *** NOTES ADDED BY LFITZGERALD 10/24/2024 10:01:25 AM *** no irrigation -no cross connection | |||
| U -UTILITY RESIDENTIAL FINAL | 10/28/2024 | FINAL APPROVED | LFITZGERALD |
| Note: 10/28/2024 - PREVIOUS INSPECTION NOTES *** NOTES ADDED BY LFITZGERALD 10/28/2024 1:38:02 PM *** both pep tanks require dedicated 20 amp breaker/pep pumps not working correctly/1 tank has pipe disdged-utility-Ivan infrmed-sendig tech out to repair Inspector Notes from Inspection 9035 *** NOTES ADDED BY LFITZGERALD 10/24/2024 10:01:25 AM *** no irrigation -no cross connection | |||
| BLD - BUILDING FINAL | 10/25/2024 | Disapproved - NO FEE | CVANSTRAHLEN |
| Note: 10/25/24 done with the inspection ( need Approval ) from city building deparment E-calcs Model number for coil no not match with documen ts 10/24/2024 - PREVIOUS INSPECTION NOTES | |||
| BLD - BUILDING FINAL | 10/24/2024 | CANCELLED BY APPLICANT | CVANSTRAHLEN |
| U-CROSS CONNECTION | 10/24/2024 | APPROVED - AS NOTED | LFITZGERALD |
| Note: *** NOTES ADDED BY LFITZGERALD 10/24/2024 10:01:25 AM *** no irrigation -no cross connection | |||
| FINAL SURVEY (OFFICE USE ONLY) | 08/14/2024 | APPROVED | PFLANAGAN |
| Note: CORRECTIONS MADE ------------------------------------------------------------------- 6/26/2024 - PREVIOUS INSPECTION NOTES WENT OUT TO LOOK AT THIS HOUSE DO TO THE FLAT NUMBERS AT THE BACK CORNERS OF THE HOUSE. WHEN OUT THERE DOING AN INSPECTION NOTICE THE FOLLOWING. 1) THE SLOPE AWAY FROM THE HOUSE IS FLAT BUT THE SURVEY SHOW .40 2) THE DRAINAGE ALONG THE SIDES IS UP AND DOWN THIS MEANS THAT THE WATER WILL NOT FLOW TO ROADSIDE SWALE. 3) SURVEY SHOWS A W SWALE ON THE RIGHT SIDE AND THERE IS NO HIGH POINT AT THE FENCE LINE ALL WATER IS FLOWING TO ADJACENT LOT. | |||
| ROW - FINAL APRON (AFTER POUR) | 08/13/2024 | APPROVED | PFLANAGAN |
| Note: At the time of the inspection all minimum city requirements were met. It is the builders and the homowners responsibility to ensure that nothing changes after this Inspection is approved. It will not be on the city if any changes after this inspection. | |||
| ROW FIELD SURVEY /GRADING CERTIFICATION | 08/13/2024 | APPROVED | PFLANAGAN |
| Note: At the time of the inspection all minimum city requirements were met. It is the builders and the homowners responsibility to ensure that nothing changes after this Inspection is approved. It will not be on the city if any changes after this inspection. --------------------------------------------------------------------- 11/6/2023 - PREVIOUS INSPECTION NOTES CANT TELL IF THE ROADSIDE SWALE WILL WORK BECAUSE THIS IS STILL A ROUGH GRADE OF THE SWALE ITS NOT DONE YET THE FINAL SURVEY WILL DETERMIND IF THE SWALE IS GOOD OR NOT BECAUSE THEY WILL BE AT FINAL GRADE NUMBERS. THIS IS THE WRONG INSPECTION FOR THIS NEXT TIME YOU NEED TO CALL AN INSPECTOR FOR A PROJECT STATUS. SO THIS WILL BE A DISAPPROVED INSPECTION WITH NO FEE. | |||
| FINAL SURVEY (OFFICE USE ONLY) | 06/25/2024 | Disapproved - NO FEE | PFLANAGAN |
| Note: WENT OUT TO LOOK AT THIS HOUSE DO TO THE FLAT NUMBERS AT THE BACK CORNERS OF THE HOUSE. WHEN OUT THERE DOING AN INSPECTION NOTICE THE FOLLOWING. 1) THE SLOPE AWAY FROM THE HOUSE IS FLAT BUT THE SURVEY SHOW .40 2) THE DRAINAGE ALONG THE SIDES IS UP AND DOWN THIS MEANS THAT THE WATER WILL NOT FLOW TO ROADSIDE SWALE. 3) SURVEY SHOWS A W SWALE ON THE RIGHT SIDE AND THERE IS NO HIGH POINT AT THE FENCE LINE ALL WATER IS FLOWING TO ADJACENT LOT. | |||
| GRAVITY SEWER TEST | 11/13/2023 | APPROVED - AS NOTED | MGIBSON |
| Note: THISWAS A VIRTUAL INSPECTION | |||
| U-CROSS CONNECTION | 11/13/2023 | CANCELLED BY APPLICANT | WEB |
| U - SEWER TIE IN | 11/13/2023 | APPROVED - AS NOTED | MGIBSON |
| Note: THIS WAS A VIRTUAL INSPECTION | |||
| ROW FIELD SURVEY /GRADING CERTIFICATION | 11/06/2023 | Disapproved - NO FEE | PFLANAGAN |
| Note: CANT TELL IF THE ROADSIDE SWALE WILL WORK BECAUSE THIS IS STILL A ROUGH GRADE OF THE SWALE ITS NOT DONE YET THE FINAL SURVEY WILL DETERMIND IF THE SWALE IS GOOD OR NOT BECAUSE THEY WILL BE AT FINAL GRADE NUMBERS. THIS IS THE WRONG INSPECTION FOR THIS NEXT TIME YOU NEED TO CALL AN INSPECTOR FOR A PROJECT STATUS. SO THIS WILL BE A DISAPPROVED INSPECTION WITH NO FEE. | |||
| ROW- PRE-APRON (PRE-POUR) | 10/25/2023 | APPROVED - AS NOTED | FSLADISH |
| Note: 10/25/23 PIPE ELEVATIONS ARE NOW WITHIN TOLERANCE. READY TO POUR AT THE TIME OF THIS INSPECTION. AT THE TIME OF THE INSPECTION CULVERT PIPE IS GOOD IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD DOUBLE CHECK CULVERT ELEVATIONS BEFORE POURING. MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL At the time of the inspection all minimum city requirements were met. It is the builders responsibiliy to ensure that nothing changes after this Inspection is approved. This includes but is not limited to, the Culvert Pipe Elevation from the time of the inspection approval to the concrete pour. 10/24/2023 - PREVIOUS INSPECTION NOTES 10/24/23 CULVERT PIPES OUT OF TOLERANCE. SPOKE TO CM HE KNOWS THEY ARE HIGH, DIDNT UNDERSTAND THE SWALE DIAGRAM. RESETTING PIPE AND SETTING REINSPECTION FOR TOMORROW. | |||
| ROW- PRE-APRON (PRE-POUR) | 10/24/2023 | Disapproved - NO FEE | FSLADISH |
| Note: 10/24/23 CULVERT PIPES OUT OF TOLERANCE. SPOKE TO CM HE KNOWS THEY ARE HIGH, DIDNT UNDERSTAND THE SWALE DIAGRAM. RESETTING PIPE AND SETTING REINSPECTION FOR TOMORROW. | |||
| ELECTRIC - EARLY POWER | 10/19/2023 | APPROVED | JWALKER |
| FIREWALL FINAL | 09/08/2023 | APPROVED | JWALKER |
| Note: 8/10/2023 - PREVIOUS INSPECTION NOTES The Draftstop in the attic space is approved. Next inspection for firewall will be firewall drywall nailing after the 5/8 rock is installed at the ceiling and firewall area. After nailing a firewall final can be done. CONTRACTOR MAY CONTINUE WITH SHEET ROCK. 8/3/23 Please have the approved duct layout print onsite at insulation inspection. | |||
| PEP TANK INSTALLATION REQUEST | 08/21/2023 | APPROVED | CBOWERMASTER |
| FIREWALL DRYWALL NAILING | 08/18/2023 | APPROVED | JWALKER |
| FIREWALL FINAL | 08/10/2023 | Disapproved - NO FEE | JWALKER |
| Note: The Draftstop in the attic space is approved. Next inspection for firewall will be firewall drywall nailing after the 5/8 rock is installed at the ceiling and firewall area. After nailing a firewall final can be done. CONTRACTOR MAY CONTINUE WITH SHEET ROCK. 8/3/23 Please have the approved duct layout print onsite at insulation inspection. | |||
| INSULATION | 08/10/2023 | APPROVED | JWALKER |
| Note: 8/8/2023 - PREVIOUS INSPECTION NOTES 8/8/23 Layout does not match what is installed 8/3/23 Please have the approved duct layout print onsite at insulation inspection. | |||
| INSULATION | 08/08/2023 | Disapproved - NO FEE | MKRASKI |
| Note: 8/8/23 Layout does not match what is installed 8/3/23 Please have the approved duct layout print onsite at insulation inspection. | |||
| FIREWALL FINAL | 08/08/2023 | Disapproved - NO FEE | MKRASKI |
| Note: 8/8/23 Layout does not match what is installed 8/3/23 Please have the approved duct layout print onsite at insulation inspection. | |||
| ALL ROUGH | 08/03/2023 | APPROVED - AS NOTED | JWALKER |
| Note: 8/3/23 Please have the approved duct layout print onsite at insulation inspection. | |||
| ALL ROUGH | 08/01/2023 | Disapproved -FEE REQUIRED | RSIMS |
| Note: 8/1/23: Inspection Stopped. Only side A inspected. Unit A: (Left Side) 1). Incomplete plans - missing Energy calcs & product approval packets. 2). 5ft head pressure not holding. 3). No water pressure. 4). Dryer exhaust not sealed at roof deck as required. 5). Need revision for different doors installed than what was originally submitted to & approved by the City. 6). Need to fill hole in concrete floor at lineset. (behing garage wall). 7). Missing Adress on both Units - Persuant to the Contractor's News letter and Florida Building Codes 319.1 & 501.2 (& Emergency Services) - Address must be marked on the exterior of the home & be visible from the street with 4" tall minimum, contrasting color lettering. (New construction - marking the windows with flourescent or reflective paint/other is acceptable). Inspector Notes from Inspection 2450 climbed in open part of ceiling and bumped sheathing, also can see nailes 7/28/2023 - PREVIOUS INSPECTION NOTES | |||
| WALL SHEATHING | 07/31/2023 | APPROVED - AS NOTED | RMARTIN |
| Note: climbed in open part of ceiling and bumped sheathing, also can see nailes 7/28/2023 - PREVIOUS INSPECTION NOTES | |||
| WALL SHEATHING | 07/28/2023 | CANCELLED BY APPLICANT | JWALKER |
| FIREWALL DRYWALL NAILING | 07/25/2023 | PARTIALLY APPROVED | JWALKER |
| Note: This inspection was for the 1/2" drywall installed on one side of truss. Firewall drywall nailing inspection will also be needed for 5/8" ceiling and separating wall. | |||
| LATH/BRICK/ WATER BARRIER | 06/29/2023 | APPROVED | KSANDOE |
| ROOF VALLEY & METAL | 06/07/2023 | APPROVED | RSIMS |
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 06/01/2023 | APPROVED | BTAYLOR |
| Note: 5/30/2023 - PREVIOUS INSPECTION NOTES 5/30/23: Inspection stopped. Incomplete inspection. * Roof sheathing has multiple areas where the gap exceeds the allowable 1/8" making the clips ineffective. Some areas have clips that are damaged. small piece areas along the ridges require blocking below because sheathing is collapsing in these areas. Check all for proper stability. * Need trash dumpster on-site and piles of trash & debris cleaned up. Persuant to the Contractor's News letter and Florida Building Codes 319.1 & 501.2 (& Emergency Services) - Address must be marked on the exterior of the home & be visible from the street with 4" tall minimum, contrasting color lettering. (New construction - marking the windows with flourescent or reflective paint/other is acceptable). 5/5/2023 - PREVIOUS INSPECTION NOTES 1. Multiple roof sheating is has missed nailing. THe 7/16 roof sheating requires blocking or edge clips Non have been installed. The Vertical run roof sheating has not been stagger. ALL of the underlayment will need to be removed and the entire roof sheating will need to be installed and nail as per the FL residential code and the WFCM. Page 25, 2.5.4.3 2. 4 of JG2 trusses and the C2 trusses are missing hold down anchors. 3. The 2 Double ply trusses # 1 are missing hold down anchors at both ends in both units. The trusses are to gang nailed together 9" o.c. stagger. Refer to Mitek packet. 4. All The truss engineering boards installed are to be the same species as the trusses SYP. Remove all NSPR boards and install SYP. 5. All lumber in contact with the CMU walls is to be pressure treated or to have a moisture barrier. Due to multiple issues listed above this inspection was stopped. A full reinspection will need to be done. ROOF SHEATING NAILING WILL NEED TO BE INSPECTED PRIOR TO ROOF BEING COVERED WITH UNDERLAYMENT, | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 05/30/2023 | Disapproved -FEE REQUIRED | RSIMS |
| Note: 5/30/23: Inspection stopped. Incomplete inspection. * Roof sheathing has multiple areas where the gap exceeds the allowable 1/8" making the clips ineffective. Some areas have clips that are damaged. small piece areas along the ridges require blocking below because sheathing is collapsing in these areas. Check all for proper stability. * Need trash dumpster on-site and piles of trash & debris cleaned up. Persuant to the Contractor's News letter and Florida Building Codes 319.1 & 501.2 (& Emergency Services) - Address must be marked on the exterior of the home & be visible from the street with 4" tall minimum, contrasting color lettering. (New construction - marking the windows with flourescent or reflective paint/other is acceptable). 5/5/2023 - PREVIOUS INSPECTION NOTES 1. Multiple roof sheating is has missed nailing. THe 7/16 roof sheating requires blocking or edge clips Non have been installed. The Vertical run roof sheating has not been stagger. ALL of the underlayment will need to be removed and the entire roof sheating will need to be installed and nail as per the FL residential code and the WFCM. Page 25, 2.5.4.3 2. 4 of JG2 trusses and the C2 trusses are missing hold down anchors. 3. The 2 Double ply trusses # 1 are missing hold down anchors at both ends in both units. The trusses are to gang nailed together 9" o.c. stagger. Refer to Mitek packet. 4. All The truss engineering boards installed are to be the same species as the trusses SYP. Remove all NSPR boards and install SYP. 5. All lumber in contact with the CMU walls is to be pressure treated or to have a moisture barrier. Due to multiple issues listed above this inspection was stopped. A full reinspection will need to be done. ROOF SHEATING NAILING WILL NEED TO BE INSPECTED PRIOR TO ROOF BEING COVERED WITH UNDERLAYMENT, | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 05/05/2023 | Disapproved -FEE REQUIRED | JWALKER |
| Note: 1. Multiple roof sheating is has missed nailing. THe 7/16 roof sheating requires blocking or edge clips Non have been installed. The Vertical run roof sheating has not been stagger. ALL of the underlayment will need to be removed and the entire roof sheating will need to be installed and nail as per the FL residential code and the WFCM. Page 25, 2.5.4.3 2. 4 of JG2 trusses and the C2 trusses are missing hold down anchors. 3. The 2 Double ply trusses # 1 are missing hold down anchors at both ends in both units. The trusses are to gang nailed together 9" o.c. stagger. Refer to Mitek packet. 4. All The truss engineering boards installed are to be the same species as the trusses SYP. Remove all NSPR boards and install SYP. 5. All lumber in contact with the CMU walls is to be pressure treated or to have a moisture barrier. Due to multiple issues listed above this inspection was stopped. A full reinspection will need to be done. ROOF SHEATING NAILING WILL NEED TO BE INSPECTED PRIOR TO ROOF BEING COVERED WITH UNDERLAYMENT, | |||
| FOUND SURVEY APPROVED (OFFICE) | 05/03/2023 | APPROVED | TBAKER |
| TIE BEAM / LINTEL | 01/18/2023 | APPROVED | JWALKER |
| Note: 1/17/2023 - PREVIOUS INSPECTION NOTES Right side front entry door missed dowel right side entering door. Toilet facilities must be onsite for next inspection. | |||
| TIE BEAM / LINTEL | 01/17/2023 | Disapproved - NO FEE | JWALKER |
| Note: Right side front entry door missed dowel right side entering door. Toilet facilities must be onsite for next inspection. | |||
| MONOLITHIC SLAB | 12/09/2022 | APPROVED | JWALKER |
| PLUMBING 1ST ROUGH UNDERGROUND | 11/21/2022 | APPROVED | MGIBSON |
| WATER METER INSTALLATION REQUEST | 10/18/2022 | APPROVED | CSTONE |
Review History
| Department | Status | Date In | Date Out |
| MECH | COMPLETE | 10/28/2024 | 10/28/2024 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| MECH | HOLD | 10/25/2024 | 10/28/2024 |
| Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Provide Energy Calcs with duct layout signed by AC contractor | |||
| MECH | COMPLETE | 08/08/2023 | 08/09/2023 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 08/01/2023 | 08/04/2023 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 05/03/2023 | 05/03/2023 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 05/03/2023 | 05/03/2023 |
| Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 06/13/2022 | 06/13/2022 |
| Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 06/13/2022 | 06/13/2022 |
| Note: Released By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 06/13/2022 | 06/13/2022 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| SW1 | COMPLETE | 06/13/2022 | 06/17/2022 |
| Note: Released By: EDWARD MADISON - - EMADISON@PALMCOASTGOV.COM | |||
| BLD | HOLD | 05/13/2022 | 05/19/2022 |
| Note: Held By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM All comments below per the 2020 Florida Building Code REVIEW COMMENTS: 1. Provide Product Approval for all exterior components. Per F.S. 471.025 and F.A.C. 61 G15-23.005. | |||
| CUSVC | COMPLETE | 05/13/2022 | 05/18/2022 |
| Note: Released By: ALYSSA ROSCOE - - | |||
| ELEC | COMPLETE | 05/13/2022 | 05/16/2022 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 05/13/2022 | 05/13/2022 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| LOCATE | COMPLETE | 05/13/2022 | 05/19/2022 |
| Note: Released By: CANDACE STONE - - CSTONE@PALMCOASTGOV.COM | |||
| MECH | COMPLETE | 05/13/2022 | 05/16/2022 |
| Note: Released By: CHRIS PISCITELLI - (386)986-3782 - CPISCITELLI@PALMCOASTGOV.COM | |||
| SW1 | COMPLETE | 05/13/2022 | 05/18/2022 |
| Note: Released By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM | |||
| ZON | HOLD | 05/13/2022 | 05/17/2022 |
| Note: Held By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM Site Plan: Please add the width of walkway in the front of home Elevation Plan: Banding around Corners: Banding must wrap corners at least two feet around the corner | |||
| SWALE | COMPLETE | 05/13/2022 | 08/01/2022 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | 06/23/2022 |
| INSPECTION - RESIDENTIAL | ¤1,031.25 | 06/23/2022 |
| PLAN REVIEW - RESIDENTIAL | ¤292.50 | 06/23/2022 |
| 3% FIRE IMPACT FEE CREDIT | (¤23.32) | 06/23/2022 |
| IMPACT FEE FIRE | ¤777.30 | 06/23/2022 |
| IMPACT FEE PARKS | ¤2,910.26 | 06/23/2022 |
| IMPACT FEE SCHOOL | ¤7,200.00 | 06/23/2022 |
| IMPACT FEE TRANSPORTATION | ¤2,738.00 | 06/23/2022 |
| WATER -IRRIGATION INSPECTION | ¤50.00 | 06/23/2022 |
| 3% PARKS IMPACT FEE CREDIT | (¤87.31) | 06/23/2022 |
| SURCHARGE FS 533.721 | ¤11.19 | 06/23/2022 |
| SURCHARGE - FS 468.631 | ¤16.79 | 06/23/2022 |
| SW ENG - FOUNDATION SURVEY | ¤20.00 | 06/23/2022 |
| SW ENG INSPECTION 80 | ¤80.00 | 06/23/2022 |
| SW ENG PRE APRON | ¤30.00 | 06/23/2022 |
| SW ENG - REVIEW 20 | ¤20.00 | 06/23/2022 |
| SW ENG RES REVIEW 200 | ¤200.00 | 06/23/2022 |
| 3% TRANS IMPACT FEE CREDIT | (¤82.14) | 06/23/2022 |
| SEWER CREDIT | (¤2,932.00) | 06/23/2022 |
| SEWER INSPECTION | ¤25.00 | 06/23/2022 |
| SEWER CAPITAL FACILITY | ¤9,879.52 | 06/23/2022 |
| WATER CAPITAL FACILITY FEE | ¤7,253.00 | 06/23/2022 |
| SITE PLAN 30 | ¤30.00 | 06/23/2022 |
| WATER- TURN ON | ¤50.00 | 06/23/2022 |
| CONNECTION FEES | ¤2,155.76 | 06/23/2022 |
| CONTRACTOR CHANGE | ¤20.00 | |
| ADMINISTRATIVE - EXTENSION | ¤40.00 | |
| REINSPECTION FEE | ¤40.00 | |
| PLAN REVIEW - REVISION | ¤32.50 | |
| PLAN REVIEW - REVISION | ¤32.50 | |
| REINSPECTION RESIDENTIAL | ¤40.00 | |
| REINSPECTION RESIDENTIAL | ¤40.00 | |
| REINSPECTION RESIDENTIAL | ¤40.00 | |
| Fees | Total Due: ¤285.00 | Total Paid: ¤31,675.80 |