I want to search for...

Permit #2022051481

Permit Details

Status: COED

Parcel Id: 07-11-31-7027-00440-0070
CONDITIONED SPACE: 2000 sqft
GARAGE: 476 sqft
OPENED PORCH (WITH ROOF) : 197 sqft
OPENED PORCH (WITH ROOF) : 144 sqft
Total Square Footage: 2817 sqft
Block: 00440
Subdivision: 2128 - SECTION 27-WYNNFIELD
Job Phone: 912-258-2201
Location Address: 77 WOODBURY DR
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 07/28/2022
NOC: RECORDED
Applicant name: JAMES FUCETOLA III
Owner: PALM COAST COMMUNITIES LLC

Address

PO BOX 22547

ST SIMONS ISLAND, FL 31522

Lot: 0070
Contracted Stated Job Value: ¤215,000.00
Job Description: Single Family Residence
Type: CN

Contractor

PALM COAST COMMUNITIES LLC
Status Location Address State License Number Phone
INACTIVE

PO BOX 22547

PALM COAST, FL 32164

CBC1262878 (Exp: 08/31/2026) 321-501-4617

Sub Contractors

JEFFREY TROY SABAKA
Status Location Address State License Number Phone Fax
ACTIVE

2191 DEERWOOD ACRES DR

ST AUGUSTINE, FL 32084

CFC1427439 (Exp: 08/31/2026) 904-838-2218 904-819-0965
OLEG BELINSKIY
Status Location Address State License Number Phone
ACTIVE

19 PINE CIRCLE DRIVE19

PALM COAST, FL 32167

CCC1325974 (Exp: 08/31/2026) 386-263-7906
WILLIAM FRANK DUDLEY JR.
Status Location Address State License Number Phone
ACTIVE

P.O. BOX 978

Bunnell, FL 32110

EC0003177 (Exp: 08/31/2026) (386)437-3068
GARY LLOYD SHEFFIELD
Status Location Address State License Number Phone
ACTIVE

48 EAGLE LAKES DRIVE

FLAGLER BEACH, FL 32136

CAC048127 (Exp: 08/31/2026) 386-597-3280

Inspection History

Type Request Date Result Inspector
BLD - BUILDING FINAL 03/21/2023 FINAL APPROVED MKRASKI
U -UTILITY RESIDENTIAL FINAL 03/21/2023 FINAL APPROVED LFITZGERALD
ROW- FINAL SURVEY/GRADING CERTIFICATION 03/16/2023 APPROVED GBERTOLA
Note: 3/16/23=CORRECTION WERE MADE AT THE TIME OF THE INSPECTION EVERYTHING LOOK GOOD +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 3/13/2023 - PREVIOUS INSPECTION NOTES 03/13/23= IN THE BACK YARD YOU ARE MOVING THE WATER TO THE BACK . YOU NEED TO MOVE THE WATER TO THE FRONT The subject lots drainage must not negatively impact any adjacent property. (B) B.Land Development Code Technical Manual, Section 300.01 (A)(1)(C)(6)
ROW FIELD SURVEY /GRADING CERTIFICATION 03/16/2023 APPROVED GBERTOLA
Note: CORRECTION WERE MADE AT THE TIME OF THE INSPECTION EVERYTHING LOOK GOOD 3/9/2023 - PREVIOUS INSPECTION NOTES final survey need to be aproved first
ROW - STORMWATER FINAL 03/16/2023 APPROVED GBERTOLA
Note: AT THE TIME OF THE INSPECTION EVERYTHING LOOK GOOD
ROW - FINAL APRON (AFTER POUR) 03/16/2023 APPROVED GBERTOLA
Note: AT THE TIME OF THE INSPECTION EVERYTHING LOOK GOOD
U - SEWER TIE IN 03/15/2023 APPROVED - AS NOTED MGIBSON
Note: THIS WAS A VIRTUAL INSPECTION
ROW- FINAL SURVEY/GRADING CERTIFICATION 03/13/2023 Disapproved - NO FEE GBERTOLA
Note: 03/13/23= IN THE BACK YARD YOU ARE MOVING THE WATER TO THE BACK . YOU NEED TO MOVE THE WATER TO THE FRONT. LOOK AT THE NUMBERS IN THE FINAL SURVEY. YOU DIDN'T BUILD THIS ACCORDING TO THE SITE PLAN The subject lots drainage must not negatively impact any adjacent property. (B) B.Land Development Code Technical Manual, Section 300.01 (A)(1)(C)(6)
ROW FIELD SURVEY /GRADING CERTIFICATION 03/09/2023 Disapproved - NO FEE GBERTOLA
Note: final survey need to be aproved first
U-CROSS CONNECTION 03/08/2023 APPROVED - AS NOTED LFITZGERALD
Note: has potable irrigation with RPZ installed-no cross connection. ALSO-SEWER CLEAN OUT RISER PIPE FULL OF WATER-MAKE SURE SEWER LINE IS CLEAR AND FUNCTIONAL BY FINAL
ELECTRIC - EARLY POWER 02/23/2023 APPROVED - AS NOTED KSANDOE
Note: Emailed FPL @ 0851. Release Power
ROW- PRE-APRON (PRE-POUR) 02/17/2023 APPROVED PFLANAGAN
Note: IT'S THE CONTRACTORS RESPONSIBILITY TO CHECK THE CULVERT PIPE ELEVATIONS BEFORE POURING THE CONCRETE FOR DRIVEWAY
LATH/BRICK/ WATER BARRIER 01/25/2023 APPROVED KSANDOE
INSULATION 01/23/2023 APPROVED MKRASKI
ALL ROUGH 01/17/2023 APPROVED MKRASKI
ROOF SHEATHING / BRACES/TIES/DOWN CELL 12/21/2022 APPROVED - AS NOTED MKRASKI
Note: 12/21/22 Adress number not visible per FBC R319.1 Correct before next inspection 12/16/2022 - PREVIOUS INSPECTION NOTES 12/16/22 1. Truss repair for T30 not repaired per plan missing 2x4 on web 11/14/2022 - PREVIOUS INSPECTION NOTES 11/4/2022 - PREVIOUS INSPECTION NOTES 1. Truss layout with truss engineering does not match home (reversed) 2. Missing straps over garage door Check all truss strapping 3. No interior load bearing wall detail on site 4. Hand framed rafters on back lani are not strapped to CMU 11/14/22 1. Truss T30 is damaged and needs engineered repairs submitted to city 2. Truss's T21, T27, HJ01, HJ05 missing straps 3. Multiple shinners on back lani near truss T26 All marked on truss layout Stopped inspection
ROOF SHEATHING / BRACES/TIES/DOWN CELL 12/16/2022 Disapproved -FEE REQUIRED MKRASKI
Note: 12/16/22 1. Truss repair for T30 not repaired per plan missing 2x4 on web 11/14/2022 - PREVIOUS INSPECTION NOTES 11/4/2022 - PREVIOUS INSPECTION NOTES 1. Truss layout with truss engineering does not match home (reversed) 2. Missing straps over garage door Check all truss strapping 3. No interior load bearing wall detail on site 4. Hand framed rafters on back lani are not strapped to CMU 11/14/22 1. Truss T30 is damaged and needs engineered repairs submitted to city 2. Truss's T21, T27, HJ01, HJ05 missing straps 3. Multiple shinners on back lani near truss T26 All marked on truss layout Stopped inspection
ROOF SHEATHING / BRACES/TIES/DOWN CELL 11/14/2022 Disapproved -FEE REQUIRED MKRASKI
Note: 11/4/2022 - PREVIOUS INSPECTION NOTES 1. Truss layout with truss engineering does not match home (reversed) 2. Missing straps over garage door Check all truss strapping 3. No interior load bearing wall detail on site 4. Hand framed rafters on back lani are not strapped to CMU 11/14/22 1. Truss T30 is damaged and needs engineered repairs submitted to city 2. Truss's T21, T27, HJ01, HJ05 missing straps 3. Multiple shinners on back lani near truss T26 All marked on truss layout Still need to check truss engineering Stopped inspection
ROOF VALLEY & METAL 11/08/2022 APPROVED MKRASKI
ROOF SHEATHING / BRACES/TIES/DOWN CELL 11/04/2022 Disapproved -FEE REQUIRED MKRASKI
Note: 1. Truss layout with truss engineering does not match home (reversed) 2. Missing straps over garage door Check all truss strapping 3. No interior load bearing wall detail on site 4. Hand framed rafters on back lani are not strapped to CMU Stopped inspection
ROOF SHEATHING / BRACES/TIES/DOWN CELL 11/03/2022 Disapproved - NO FEE MKRASKI
Note: Not ready workers still working
ROOF SHEATHING 11/03/2022 APPROVED MKRASKI
WALL SHEATHING 10/27/2022 CANCELLED BY INSPECTOR DCUSHING
Note: N/A - no wall sheathing
ROOF SHEATHING 10/27/2022 Disapproved - NO FEE RSIMS
Note: 10/27/2022: INSPECTION STOPPED 1). right side of garage has loose plywood. (marked on wall with an arrow below area) 2). Back left & center areas the gap between the sheets of plywood is excessive making the clips ineffective. (Plywood sinks in when walked on.) 3). Right front area - clips are not flush with plywood.
FOUND SURVEY APPROVED (OFFICE) 10/18/2022 APPROVED TBAKER
TIE BEAM / LINTEL 10/10/2022 APPROVED MKRASKI
MONOLITHIC SLAB 09/15/2022 APPROVED MKRASKI
MONOLITHIC SLAB 09/14/2022 CANCELLED BY APPLICANT MKRASKI
Note: THIS IS A REINSPECTION 1. No compaction report in Doc-box FBC 404.1 Stopped inspection
MONOLITHIC SLAB 09/13/2022 Disapproved -FEE REQUIRED MKRASKI
Note: 1. No compaction report in Doc-box FBC 404.1 Stopped inspection
PLUMBING 1ST ROUGH UNDERGROUND 09/12/2022 APPROVED - AS NOTED MGIBSON
Note: THE P-TRAP FOR HANSEN BOX'' W/M'' IS UNDER THE SLAB!!!
GRAVITY SEWER TEST 09/12/2022 APPROVED MGIBSON
WATER METER INSTALLATION REQUEST 08/05/2022 APPROVED CSTONE

Review History

Department Status Date In Date Out
BLD COMPLETE 12/02/2022 12/05/2022
Note: Released By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM
BLD COMPLETE 11/18/2022 11/18/2022
Note: Released By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM
ENGIN1 COMPLETE 10/18/2022 10/18/2022
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
ZON COMPLETE 10/18/2022 10/18/2022
Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM
ZON COMPLETE 06/09/2022 06/09/2022
Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM
BLD COMPLETE 05/25/2022 05/31/2022
Note: Released By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM
CUSVC COMPLETE 05/25/2022 05/31/2022
Note: Released By: CYNTHIA SCHWEERS - - CSCHWEERS@PALMCOASSTGOV.COM
ELEC COMPLETE 05/25/2022 05/26/2022
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
ENGIN1 COMPLETE 05/25/2022 05/25/2022
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
LOCATE COMPLETE 05/25/2022 05/27/2022
Note: Released By: CANDACE STONE - - CSTONE@PALMCOASTGOV.COM
MECH COMPLETE 05/25/2022 05/26/2022
Note: Released By: CHRIS PISCITELLI - (386)986-3782 - CPISCITELLI@PALMCOASTGOV.COM
SW1 COMPLETE 05/25/2022 05/26/2022
Note: Released By: ROBERT GROSS - (386)986-4769 - RGROSS@PALMCOASTGOV.COM
ZON HOLD 05/25/2022 05/26/2022
Note: Held By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM AC must be screened with 7 gallon shrubs
SWALE COMPLETE 05/25/2022 08/11/2022
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
PLAN REVIEW - REVISION ¤32.50 03/21/2023
PLAN REVIEW - REVISION ¤32.50 03/21/2023
REINSPECTION RESIDENTIAL ¤40.00 03/21/2023
REINSPECTION RESIDENTIAL ¤40.00 03/21/2023
REINSPECTION RESIDENTIAL ¤40.00 03/21/2023
REINSPECTION RESIDENTIAL ¤40.00 03/21/2023
CONNECTION FEES ¤1,077.88 07/28/2022
3% FIRE IMPACT FEE CREDIT (¤11.66) 07/28/2022
IMPACT FEE FIRE ¤388.65 07/28/2022
IMPACT FEE PARKS ¤1,455.13 07/28/2022
IMPACT FEE SCHOOL ¤3,600.00 07/28/2022
IMPACT FEE TRANSPORTATION ¤1,764.00 07/28/2022
WATER -IRRIGATION INSPECTION ¤25.00 07/28/2022
3% PARKS IMPACT FEE CREDIT (¤43.65) 07/28/2022
SURCHARGE FS 533.721 ¤7.81 07/28/2022
SURCHARGE - FS 468.631 ¤11.71 07/28/2022
SW ENG - FOUNDATION SURVEY ¤20.00 07/28/2022
SW ENG INSPECTION 80 ¤80.00 07/28/2022
SW ENG PRE APRON ¤30.00 07/28/2022
SW ENG - REVIEW 20 ¤20.00 07/28/2022
SW ENG RES REVIEW 200 ¤200.00 07/28/2022
3% TRANS IMPACT FEE CREDIT (¤52.92) 07/28/2022
SEWER CREDIT (¤1,147.00) 07/28/2022
SEWER INSPECTION ¤25.00 07/28/2022
SEWER CAPITAL FACILITY ¤4,939.76 07/28/2022
WATER CAPITAL FACILITY FEE ¤3,626.50 07/28/2022
SITE PLAN 30 ¤30.00 07/28/2022
WATER- TURN ON ¤25.00 07/28/2022
ADMINISTRATIVE RESIDENTIAL ¤30.00 07/28/2022
INSPECTION - RESIDENTIAL ¤701.25 07/28/2022
PLAN REVIEW - RESIDENTIAL ¤198.90 07/28/2022
Fees Total Due: ¤0.00 Total Paid: ¤17,226.36