I want to search for...

Permit #2022051708

Permit Details

Status: COED

Parcel Id: 07-11-31-7027-00490-0250
CONDITIONED SPACE: 2091 sqft
GARAGE: 770 sqft
OPENED PORCH (WITH ROOF) : 371 sqft
OPENED PORCH (WITH ROOF) : 72 sqft
Total Square Footage: 3304 sqft
Block: 00490
Subdivision: 2128 - SECTION 27-WYNNFIELD
Job Phone: (386) 445-2222
Location Address: 31 WOODBURY DR
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 07/18/2022
NOC: RECORDED
Applicant name: MICHAEL STEPHAN MULLEN
Owner: MULLEN CONSTRUCTION COMPANY INC

Address

UNIT13

BUNNELL, FL 32110

Address

1 ENTERPRISE DR

BUNNELL, FL 32110

Lot: 0250
Contracted Stated Job Value: ¤210,000.00
Job Description: SINGLE FAMILY RESIDENTIAL
Type: CN

Contractor

TOWN & COUNTRY HOMES
Status Location Address State License Number Phone
ACTIVE

1 Enterprise Drive

Bunnell, FL 32110

CGC049972 (Exp: 08/31/2026) (386) 445-2222

Inspection History

Type Request Date Result Inspector
BLD - BUILDING FINAL 07/07/2023 FINAL APPROVED JWALKER
Note: 6/22/2023 - PREVIOUS INSPECTION NOTES 1. Built in microwave requires breaker lock NEC 422.30 2. Front window (dining) is cracked 3. Energy cals do not match
ROW - STORMWATER FINAL 06/27/2023 APPROVED PFLANAGAN
Note: At the time of the inspection all minimum city requirements were met. It is the builders responsibiliy to ensure that nothing changes after this Inspection is approved. --------------------------------------------------------------------------------- 6/23/2023 - PREVIOUS INSPECTION NOTES WATER SITTING IN RIGHT SIDE ALONG FENCE NEED TO FIX SO WATER DONT HOLD THERE ---------------------------------------------------------------------------------- 6/22/2023 - PREVIOUS INSPECTION NOTES CANCELLED DO TO NOT READY FOR INSPECTION. 1) NEED TO HAVE SEED AND STRAW BEHIND THE FENCE 2) NEED TO PICK UP ALL TRASH AND CONSTRUCTION DEBRIS BEHIND FENCE 3) THEY WERE PUMPING OUT SWALE AT TIME OF INSPECTION TAKE NOTE ON CULVERTS AND GRADE OF SWALE WHEN IT'S PUMPED OUT
ROW - STORMWATER FINAL 06/23/2023 Disapproved - NO FEE PFLANAGAN
Note: WATER SITTING IN RIGHT SIDE ALONG FENCE NEED TO FIX SO WATER DONT HOLD THERE ---------------------------------------------------------------------------------- 6/22/2023 - PREVIOUS INSPECTION NOTES CANCELLED DO TO NOT READY FOR INSPECTION. 1) NEED TO HAVE SEED AND STRAW BEHIND THE FENCE 2) NEED TO PICK UP ALL TRASH AND CONSTRUCTION DEBRIS BEHIND FENCE 3) THEY WERE PUMPING OUT SWALE AT TIME OF INSPECTION TAKE NOTE ON CULVERTS AND GRADE OF SWALE WHEN IT'S PUMPED OUT
BLD - BUILDING FINAL 06/22/2023 Disapproved - NO FEE MKRASKI
Note: 1. Built in microwave requires breaker lock NEC 422.30 2. Front window (dining) is cracked 3. Energy cals do not match
ROW - STORMWATER FINAL 06/22/2023 CANCELLED BY APPLICANT PFLANAGAN
Note: CANCELLED DO TO NOT READY FOR INSPECTION. 1) NEED TO HAVE SEED AND STRAW BEHIND THE FENCE 2) NEED TO PICK UP ALL TRASH AND CONSTRUCTION DEBRIS BEHIND FENCE 3) THEY WERE PUMPING OUT SWALE AT TIME OF INSPECTION TAKE NOTE ON CULVERTS AND GRADE OF SWALE WHEN IT'S PUMPED OUT
ROW - FINAL APRON (AFTER POUR) 06/20/2023 APPROVED GBERTOLA
Note: 6/20/23= At the time of the inspection all minimum city requirements were met. It is the builders responsibility to ensure that nothing changes after this Inspection is approved
U -UTILITY RESIDENTIAL FINAL 06/20/2023 FINAL APPROVED LFITZGERALD
ROW- FINAL SURVEY/GRADING CERTIFICATION 06/12/2023 APPROVED FSLADISH
Note: 06/12/23 Inspector Notes from Inspection 9270 5/9/23=CORRECTION WERE MADE AT THE TIME OF THE INSPECTION CULVERT PIPE IS GOOD IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD DOUBLE CHECK CULVERT ELEVATIONS BEFORE POURING. MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 5/8/2023 - PREVIOUS INSPECTION NOTES FORM BOARD BY THE ROAD EDGE IS DOWN, NEED TO MOVE THE FORM BOARD A COUPLE INCHES INSIDE FROM THE ROAD EDGE OUT OF THE CITY ROAD I LEFETED (AREA MARKED WITH WHITE SPRAY PAINT) NEED TO REMOVE THE WOOD STAKES OUT OF THE CITY ROAD. NEED TO RAISE THE FORM BOARD BY THE EDGE OF PAVEMENT ABOVE EDGE PICTURES ATTACHED ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
ROW FIELD SURVEY /GRADING CERTIFICATION 06/12/2023 APPROVED - AS NOTED FSLADISH
Note: 06/12/23 A COUPLE LOW SPOTS HOLDING WATER. MOSTLY DUE TO NEW CONSTUCTION GRADE FALLING ON RIGHT SIDE. RECHECK BEFORE ROW FINAL FOR CORRECT DRAINAGE, HEAVY RAIN LAST NIGHT. SWALE IS FULL DUE TO HIGH SPOT AT LEFT SIDE PROPERTY OWNERS CULVERT END.
ELECTRIC - EARLY POWER 06/12/2023 APPROVED - AS NOTED MKRASKI
Note: Emailed FPL @ 10:30 AM
U-CROSS CONNECTION 06/08/2023 APPROVED - AS NOTED LFITZGERALD
Note: no irrigation-no cross connection
ELECTRIC - EARLY POWER 05/19/2023 Disapproved - NO FEE TSTAUFFACHER
Note: 05/19/2023- The work is approved and ready to call for FPL, waiting on approval from revision. On this date, it had been submitted and noted, but not yet approved. Inspector Notes from Inspection 2200 Emailed FPL @ 10:50 AM Need revision form over head to under ground service before next inspection
ROW- PRE-APRON (PRE-POUR) 05/09/2023 APPROVED - AS NOTED GBERTOLA
Note: 5/9/23=CORRECTION WERE MADE AT THE TIME OF THE INSPECTION CULVERT PIPE IS GOOD IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD DOUBLE CHECK CULVERT ELEVATIONS BEFORE POURING. MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 5/8/2023 - PREVIOUS INSPECTION NOTES FORM BOARD BY THE ROAD EDGE IS DOWN, NEED TO MOVE THE FORM BOARD A COUPLE INCHES INSIDE FROM THE ROAD EDGE OUT OF THE CITY ROAD I LEFETED (AREA MARKED WITH WHITE SPRAY PAINT) NEED TO REMOVE THE WOOD STAKES OUT OF THE CITY ROAD. NEED TO RAISE THE FORM BOARD BY THE EDGE OF PAVEMENT ABOVE EDGE PICTURES ATTACHED ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
ROW- PRE-APRON (PRE-POUR) 05/08/2023 Disapproved -FEE REQUIRED GBERTOLA
Note: FORM BOARD BY THE ROAD EDGE IS DOWN, NEED TO MOVE THE FORM BOARD A COUPLE INCHES INSIDE FROM THE ROAD EDGE OUT OF THE CITY ROAD I LEFETED (AREA MARKED WITH WHITE SPRAY PAINT) NEED TO REMOVE THE WOOD STAKES OUT OF THE CITY ROAD. NEED TO RAISE THE FORM BOARD BY THE EDGE OF PAVEMENT ABOVE EDGE PICTURES ATTACHED ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
ELECTRIC-TUG 05/03/2023 APPROVED - AS NOTED MKRASKI
Note: Emailed FPL @ 10:50 AM Need revision form over head to under ground service before next inspection
LATH/BRICK/ WATER BARRIER 04/10/2023 APPROVED MKRASKI
INSULATION 03/27/2023 APPROVED MKRASKI
INSULATION 03/24/2023 Disapproved - NO FEE MKRASKI
Note: Wood frame garage wall need to be sealed at base plate and edges
ALL ROUGH 03/17/2023 APPROVED - AS NOTED MKRASKI
Note: 1. Tub must be filled with water 2. Failed 5' head pressure test Check @ next inspection
WALL SHEATHING 03/15/2023 APPROVED MKRASKI
ROOF SHEATHING / BRACES/TIES/DOWN CELL 03/15/2023 APPROVED - AS NOTED MKRASKI
Note: 3/15/23 Truss A09 missing engineering check on next inspection 3/9/2023 - PREVIOUS INSPECTION NOTES 3/9/23 Reapairs made to truss A09 not made per letter, stopped inspection 2/28/2023 - PREVIOUS INSPECTION NOTES 2/28/23 1. Truss A09 engineered repair letter has not been submitted to the city, stopped inspection 2. Truss A16 missing bracing 3. Truss A17 missing bracing 4. Truss B07 missing bracing 2/1/2023 - PREVIOUS INSPECTION NOTES 2/1/23 1. Truss A09 needs repair engineered letter for 2 locations and is missing bracing 2. Truss A16 missing bracing 3. Truss A17 missing bracing 4. Truss B07 missing bracing 1/31/2023 - PREVIOUS INSPECTION NOTES 1. Truss T38 missing strap 2. Truss CJ01 misssing strap 3. Truss CJ04 missing strap approved roof sheathing, only looked at strapping nothing else
ROOF SHEATHING / BRACES/TIES/DOWN CELL 03/09/2023 Disapproved -FEE REQUIRED MKRASKI
Note: 3/9/23 Reapairs made to truss A09 not made per letter, stopped inspection 2/28/2023 - PREVIOUS INSPECTION NOTES 2/28/23 1. Truss A09 engineered repair letter has not been submitted to the city, stopped inspection 2. Truss A16 missing bracing 3. Truss A17 missing bracing 4. Truss B07 missing bracing 2/1/2023 - PREVIOUS INSPECTION NOTES 2/1/23 1. Truss A09 needs repair engineered letter for 2 locations and is missing bracing 2. Truss A16 missing bracing 3. Truss A17 missing bracing 4. Truss B07 missing bracing 1/31/2023 - PREVIOUS INSPECTION NOTES 1. Truss T38 missing strap 2. Truss CJ01 misssing strap 3. Truss CJ04 missing strap approved roof sheathing, only looked at strapping nothing else
WALL SHEATHING 03/09/2023 Disapproved -FEE REQUIRED MKRASKI
Note: Wall sheathing has been covered, siding needs to be removed to see nailing pattern
ROOF SHEATHING / BRACES/TIES/DOWN CELL 02/28/2023 Disapproved -FEE REQUIRED MKRASKI
Note: 2/28/23 1. Truss A09 engineered repair letter has not been submitted to the city, stopped inspection 2. Truss A16 missing bracing 3. Truss A17 missing bracing 4. Truss B07 missing bracing 2/1/2023 - PREVIOUS INSPECTION NOTES 2/1/23 1. Truss A09 needs repair engineered letter for 2 locations and is missing bracing 2. Truss A16 missing bracing 3. Truss A17 missing bracing 4. Truss B07 missing bracing 1/31/2023 - PREVIOUS INSPECTION NOTES 1. Truss T38 missing strap 2. Truss CJ01 misssing strap 3. Truss CJ04 missing strap approved roof sheathing, only looked at strapping nothing else
ROOF VALLEY & METAL 02/28/2023 APPROVED MKRASKI
Note: 2/22/2023 - PREVIOUS INSPECTION NOTES 1. Not ready missing drip edge, no shingles should be installed untill after this inspection, sections of the roof have been shingled
ROOF VALLEY & METAL 02/22/2023 Disapproved - NO FEE MKRASKI
Note: 1. Not ready missing drip edge, no shingles should be installed untill after this inspection, sections of the roof have been shingled
ROOF VALLEY & METAL 02/21/2023 CANCELLED BY APPLICANT MKRASKI
ROOF SHEATHING / BRACES/TIES/DOWN CELL 02/01/2023 Disapproved -FEE REQUIRED MKRASKI
Note: 2/1/23 1. Truss A09 needs repair engineered letter for 2 locations and is missing bracing 2. Truss A16 missing bracing 3. Truss A17 missing bracing 4. Truss B07 missing bracing 1/31/2023 - PREVIOUS INSPECTION NOTES 1. Truss T38 missing strap 2. Truss CJ01 misssing strap 3. Truss CJ04 missing strap approved roof sheathing, only looked at strapping nothing else
ROOF SHEATHING / BRACES/TIES/DOWN CELL 01/31/2023 Disapproved - NO FEE MKRASKI
Note: 1. Truss T38 missing strap 2. Truss CJ01 misssing strap 3. Truss CJ04 missing strap approved roof sheathing, only looked at strapping nothing else
ROOF SHEATHING 01/31/2023 APPROVED MKRASKI
TIE BEAM / LINTEL 12/12/2022 APPROVED FWILLIS
FOUND SURVEY APPROVED (OFFICE) 12/01/2022 APPROVED TBAKER
MONOLITHIC SLAB 10/17/2022 APPROVED MKRASKI
PLUMBING 1ST ROUGH UNDERGROUND 10/06/2022 APPROVED MGIBSON
GRAVITY SEWER TEST 10/06/2022 APPROVED MGIBSON
WATER METER INSTALLATION REQUEST 10/06/2022 APPROVED CSTONE
U - SEWER TIE IN 10/06/2022 APPROVED MGIBSON

Review History

Department Status Date In Date Out
MECH COMPLETE 06/27/2023 06/27/2023
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
ELEC COMPLETE 05/17/2023 05/22/2023
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
BLD COMPLETE 03/03/2023 03/07/2023
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
BADMIN INFORMATION 02/27/2023 02/27/2023
Note: Marked INFORMATION By: SCOTT THOMAS - - STHOMAS@PALMCOASTGOV.COM RENAME TO TRUSS.PDF
BADMIN COMPLETE 02/15/2023 02/15/2023
Note: Released By: SCOTT THOMAS - - STHOMAS@PALMCOASTGOV.COM RENAME TO TRUSS.PDF
ENGIN1 COMPLETE 12/01/2022 12/01/2022
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
ZON COMPLETE 12/01/2022 12/01/2022
Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM
ELEC COMPLETE 06/17/2022 06/21/2022
Note: Released By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM
ZON COMPLETE 06/17/2022 06/17/2022
Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM
BLD COMPLETE 06/17/2022 06/17/2022
Note: Released By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM
ENGIN1 COMPLETE 06/17/2022 06/21/2022
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
SW1 COMPLETE 06/17/2022 06/27/2022
Note: Released By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM
BLD HOLD 05/31/2022 06/02/2022
Note: Held By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM All comments below per the 2020 Florida Building Code – Residential REVIEW COMMENTS: 1. Provide Product Approval for the following; Per F.S. 471.025 and F.A.C. 61 G15-23.005. Per F.S. a. Truss Plate, Wood Anchors and Wood Connectors.
CUSVC COMPLETE 05/31/2022 05/31/2022
Note: Released By: CYNTHIA SCHWEERS - - CSCHWEERS@PALMCOASSTGOV.COM
ELEC HOLD 05/31/2022 05/31/2022
Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. Upload electric plan 2. Electric load calcs are not legible
ENGIN1 COMPLETE 05/31/2022 05/31/2022
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
LOCATE COMPLETE 05/31/2022 06/07/2022
Note: Released By: CANDACE STONE - - CSTONE@PALMCOASTGOV.COM
MECH COMPLETE 05/31/2022 05/31/2022
Note: Released By: CHRIS PISCITELLI - (386)986-3782 - CPISCITELLI@PALMCOASTGOV.COM
SW1 COMPLETE 05/31/2022 06/07/2022
Note: Released By: EDWARD MADISON - - EMADISON@PALMCOASTGOV.COM
ZON HOLD 05/31/2022 06/02/2022
Note: Held By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM Ac pad location missing on site plan
SWALE COMPLETE 05/31/2022 08/16/2022
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
PLAN REVIEW - REVISION ¤32.50 07/12/2023
REINSPECTION RESIDENTIAL ¤40.00 07/12/2023
REINSPECTION RESIDENTIAL ¤40.00 07/12/2023
REINSPECTION RESIDENTIAL ¤40.00 07/12/2023
REINSPECTION RESIDENTIAL ¤40.00 07/12/2023
SW ENG REINSPECTION 30 ¤30.00 07/12/2023
SW ENG - REVIEW 20 ¤20.00 07/18/2022
SW ENG RES REVIEW 200 ¤200.00 07/18/2022
3% TRANS IMPACT FEE CREDIT (¤52.92) 07/18/2022
SEWER CREDIT (¤1,466.00) 07/18/2022
SEWER INSPECTION ¤25.00 07/18/2022
SEWER CAPITAL FACILITY ¤4,939.76 07/18/2022
WATER CAPITAL FACILITY FEE ¤3,626.50 07/18/2022
SITE PLAN 30 ¤30.00 07/18/2022
WATER- TURN ON ¤25.00 07/18/2022
ADMINISTRATIVE RESIDENTIAL ¤30.00 07/18/2022
INSPECTION - RESIDENTIAL ¤775.50 07/18/2022
PLAN REVIEW - RESIDENTIAL ¤219.96 07/18/2022
CONNECTION FEES ¤1,077.88 07/18/2022
3% FIRE IMPACT FEE CREDIT (¤11.66) 07/18/2022
IMPACT FEE FIRE ¤388.65 07/18/2022
IMPACT FEE PARKS ¤1,455.13 07/18/2022
IMPACT FEE SCHOOL ¤3,600.00 07/18/2022
IMPACT FEE TRANSPORTATION ¤1,764.00 07/18/2022
WATER -IRRIGATION INSPECTION ¤25.00 07/18/2022
3% PARKS IMPACT FEE CREDIT (¤43.65) 07/18/2022
SURCHARGE FS 533.721 ¤8.57 07/18/2022
SURCHARGE - FS 468.631 ¤12.86 07/18/2022
SW ENG - FOUNDATION SURVEY ¤20.00 07/18/2022
SW ENG INSPECTION 80 ¤80.00 07/18/2022
SW ENG PRE APRON ¤30.00 07/18/2022
Fees Total Due: ¤0.00 Total Paid: ¤17,002.08