Permit #2022060070
Permit Details
Status: COED
| Parcel Id: 07-11-31-7014-00070-1750 |
| CONDITIONED SPACE: 3637 sqft |
| GARAGE: 761 sqft |
| OPENED PORCH (WITH ROOF) : 733 sqft |
| Total Square Footage: 5131 sqft |
| Block: 00070 |
| Subdivision: 2202 - SECTION 14-COUNTRY CLUB COVE |
| Job Phone: 863-647-5815 |
| Location Address: 39 CLEVELAND CT |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 07/15/2022 |
| NOC: RECORDED |
| Applicant name: MARK ALLAN HULBERT |
| Owner: PETERS ELNA KARIN & DAVID C H&W |
|
Address 5837 RIVERBLUFF DRIVE TIMNATH, CO 80547 |
| Lot: 1750 |
| Contracted Stated Job Value: ¤700,000.00 |
| Job Description: SINGLE FAMILY RESIDENCE |
| Type: CN |
Contractor
HULBERT HOMES INC
| Status | Location Address | State License Number | Phone |
| INACTIVE |
PO BOX 6254 LAKELAND, FL 33813 |
CRC1331304 (Exp: 08/31/2026) | 863-647-5815 |
Sub Contractors
JOHN EDWARD GAMBONE
| Status | Location Address | Mailing Address | State License Number | Phone |
| ACTIVE |
15 HARGROVE LN PALM COAST, FL 32137 |
1G PALM COAST, FL 32137 |
EC13006037 (Exp: 08/31/2026) | 386-586-9144 |
BOB BELL
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
3200 PARKER DRIVE ST AUGUSTINE, FL 32084 |
LG35711 (Exp: 08/31/2027) | 904-417-6470 | 877-566-4016 |
ANTONIO VINCENZO DAHM
| Status | Location Address | State License Number | Phone |
| ACTIVE |
10 RYBAR LANE PALM COAST, FL 32164 |
CFC1429951 (Exp: 08/31/2026) | 386-237-5692 |
MOISES MERINO DIAZ
| Status | Location Address | State License Number | Phone |
| ACTIVE |
3104 ORANOLE ROAD ORLANDO, FL 32810 |
CAC1820980 (Exp: 08/31/2026) | 407-225-3149 |
DUSTIN L ESTEP
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
2041 N HIAWASSEE RD APOPKA, FL 32703 |
CCC1330971 (Exp: 08/31/2026) | 407-702-0206 | 352-988-6629 |
Inspection History
| Type | Request Date | Result | Inspector |
| ROW - FINAL INSPECTION | 12/01/2023 | Disapproved - NO FEE | EMADISON |
| Note: ** 12/01/23 NEED TO SOD OR FINISH LANSCAPE ON ALL DISTURBED EARTH TO ASSIST IN EROSION CONTROL | |||
| ROW - FINAL INSPECTION | 11/03/2023 | APPROVED | EMADISON |
| Note: ** 11/03/23 READY TO POUR ENSURE NO WATER IN FORMED UP AREA TO BE POUR | |||
| BLD - BUILDING FINAL | 10/17/2023 | FINAL APPROVED | LMILLER |
| Note: 10-17-23 Notes below resolved 10/10/2023 - PREVIOUS INSPECTION NOTES 10/5/2023 - PREVIOUS INSPECTION NOTES 9/28/2023 - PREVIOUS INSPECTION NOTES 9/28/2023 - PREVIOUS INSPECTION NOTES 9/27/2023 - PREVIOUS INSPECTION NOTES Inspector Notes from Inspection 2320 05-19-2023 Entry on second floor needs additional staples. 09-27-2023 1. Steps not per code. R311.7.5.1Risers not per code. Top step to second floor is a tripping hazard. 2. Job Johnny on site. 3. No water throughout house. 4. Multiple lights not working and no switched receptacle. Stopped inspection. Inspection stopped. 09-28-2023 Met with Holly Hulbert at site. Inspection cancelled by applicant. 09-28-2023 As per Building Official: 1. Risers not within 3/8". R311.7.5.1 2. Top step is a tripping hazard. Landings must be a smooth uninterrupted surface. 3. Riser is 8" R311.7.5.1. Inspection stopped. 10-5-2023 1. Top step is a tripping hazard. Landings must be a smooth uninterrupted surface. 2. Back right bedroom step not per code. R311.7.5.1Risers. From top of threshold not more that 7 3/4". 3. Attic AHU breaker not labeled. 4. Holes in garage must be sealed. 5. Pool guard not per code. R312.1 Guards 6. FALL PROTECTION REQUIRED GUARDS…. R312.1.3 GUARDS SHALL NOT HAVE OPENINGS THAT ALLOW A 4” SPHERE TO PASS THROUGH. Pool guard. Inspection stopped. 10-10-2023 1. Steps to second floor not per code. Risers not within 3/8". R311.7.5.1. Check 3rd, 4th, 5th risers after landing. Check all risers. 2. Top step is a tripping hazard. Landings must be a smooth uninterrupted surface. 3. AHU in attic breaker is not labeled. | |||
| BLD - BUILDING FINAL | 10/10/2023 | Disapproved - NO FEE | AGAETANO |
| Note: 10/5/2023 - PREVIOUS INSPECTION NOTES 9/28/2023 - PREVIOUS INSPECTION NOTES 9/28/2023 - PREVIOUS INSPECTION NOTES 9/27/2023 - PREVIOUS INSPECTION NOTES Inspector Notes from Inspection 2320 05-19-2023 Entry on second floor needs additional staples. 09-27-2023 1. Steps not per code. R311.7.5.1Risers not per code. Top step to second floor is a tripping hazard. 2. Job Johnny on site. 3. No water throughout house. 4. Multiple lights not working and no switched receptacle. Stopped inspection. Inspection stopped. 09-28-2023 Met with Holly Hulbert at site. Inspection cancelled by applicant. 09-28-2023 As per Building Official: 1. Risers not within 3/8". R311.7.5.1 2. Top step is a tripping hazard. Landings must be a smooth uninterrupted surface. 3. Riser is 8" R311.7.5.1. Inspection stopped. 10-5-2023 1. Top step is a tripping hazard. Landings must be a smooth uninterrupted surface. 2. Back right bedroom step not per code. R311.7.5.1Risers. From top of threshold not more that 7 3/4". 3. Attic AHU breaker not labeled. 4. Holes in garage must be sealed. 5. Pool guard not per code. R312.1 Guards 6. FALL PROTECTION REQUIRED GUARDS…. R312.1.3 GUARDS SHALL NOT HAVE OPENINGS THAT ALLOW A 4” SPHERE TO PASS THROUGH. Pool guard. Inspection stopped. 10-10-2023 1. Steps to second floor not per code. Risers not within 3/8". R311.7.5.1. Check 3rd, 4th, 5th risers after landing. Check all risers. 2. Top step is a tripping hazard. Landings must be a smooth uninterrupted surface. 3. AHU in attic breaker is not labeled. | |||
| BLD - BUILDING FINAL | 10/05/2023 | Disapproved - NO FEE | AGAETANO |
| Note: 9/28/2023 - PREVIOUS INSPECTION NOTES 9/28/2023 - PREVIOUS INSPECTION NOTES 9/27/2023 - PREVIOUS INSPECTION NOTES Inspector Notes from Inspection 2320 05-19-2023 Entry on second floor needs additional staples. 09-27-2023 1. Steps not per code. R311.7.5.1Risers not per code. Top step to second floor is a tripping hazard. 2. Job Johnny on site. 3. No water throughout house. 4. Multiple lights not working and no switched receptacle. Stopped inspection. Inspection stopped. 09-28-2023 Met with Holly Hulbert at site. Inspection cancelled by applicant. 09-28-2023 As per Building Official: 1. Risers not within 3/8". R311.7.5.1 2. Top step is a tripping hazard. Landings must be a smooth uninterrupted surface. 3. Riser is 8" R311.7.5.1. Inspection stopped. 10-5-2023 1. Top step is a tripping hazard. Landings must be a smooth uninterrupted surface. 2. Back right bedroom step not per code. R311.7.5.1Risers. From top of threshold not more that 7 3/4". 3. Attic AHU breaker not labeled. 4. Holes in garage must be sealed. 5. Pool guard not per code. R312.1 Guards 6. FALL PROTECTION REQUIRED GUARDS…. R312.1.3 GUARDS SHALL NOT HAVE OPENINGS THAT ALLOW A 4” SPHERE TO PASS THROUGH. Pool guard. 7. Generac panel has been installed and is not on approved drawings. Inspection stopped. | |||
| ROW - STORMWATER FINAL | 10/04/2023 | APPROVED | EMADISON |
| ELEVATION CERTIFICATE-FINAL APPROVAL | 10/03/2023 | APPROVED | JMYERS |
| U -UTILITY RESIDENTIAL FINAL | 09/29/2023 | FINAL APPROVED | DHANEY |
| Note: 9/27/2023 - PREVIOUS INSPECTION NOTES Water service line leaking at outlet of water meter pit box - leak needs repaired . | |||
| BLD - BUILDING FINAL | 09/28/2023 | CANCELLED BY APPLICANT | AGAETANO |
| Note: 9/27/2023 - PREVIOUS INSPECTION NOTES Inspector Notes from Inspection 2320 05-19-2023 Entry on second floor needs additional staples. 09-27-2023 1. Steps not per code. R311.7.5.1Risers not per code. Top step to second floor is a tripping hazard. 2. Job Johnny on site. 3. No water throughout house. 4. Multiple lights not working and no switched receptacle. Stopped inspection. Inspection stopped. 09-28-2023 Met with Holly Hulbert at site. Inspection cancelled by applicant. | |||
| BLD - BUILDING FINAL | 09/28/2023 | Disapproved - NO FEE | AGAETANO |
| Note: 9/28/2023 - PREVIOUS INSPECTION NOTES 9/27/2023 - PREVIOUS INSPECTION NOTES Inspector Notes from Inspection 2320 05-19-2023 Entry on second floor needs additional staples. 09-27-2023 1. Steps not per code. R311.7.5.1Risers not per code. Top step to second floor is a tripping hazard. 2. Job Johnny on site. 3. No water throughout house. 4. Multiple lights not working and no switched receptacle. Stopped inspection. Inspection stopped. 09-28-2023 Met with Holly Hulbert at site. Inspection cancelled by applicant. 09-28-2023 As per Building Official: 1. Risers not within 3/8". R311.7.5.1 2. Top step is a tripping hazard. Landings must be a smooth uninterrupted surface. 3. Riser is 8" R311.7.5.1. Inspection stopped. | |||
| BLD - BUILDING FINAL | 09/27/2023 | Disapproved -FEE REQUIRED | AGAETANO |
| Note: Inspector Notes from Inspection 2320 05-19-2023 Entry on second floor needs additional staples. 09-27-2023 1. Steps not per code. R311.7.5.1Risers not per code. Top step to second floor is a tripping hazard. Top tread not 10". Board has been cut. Landings need to be level. 2. Job Johnny on site. 3. No water throughout house. 4. Multiple lights not working and no switched receptacle. Stopped inspection. Inspection stopped. | |||
| ROW - FINAL APRON (AFTER POUR) | 09/27/2023 | APPROVED - AS NOTED | EMADISON |
| Note: ** 09/27/23 NOTE DISPOSAL COMPANY BROKE A FEW PAVERS IN DRIVEWAY WHEN REMOVING DUMPSTER ARE BEING REPLACED PER BUILDER (CM HOLLY) | |||
| U -UTILITY RESIDENTIAL FINAL | 09/27/2023 | Disapproved - NO FEE | DHANEY |
| Note: Water service line leaking at outlet of water meter pit box - leak needs repaired . | |||
| ROW - STORMWATER FINAL | 09/27/2023 | CANCELLED BY APPLICANT | EMADISON |
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 09/25/2023 | APPROVED | RGROSS |
| ROW FIELD SURVEY /GRADING CERTIFICATION | 09/25/2023 | APPROVED | RGROSS |
| TUB SET | 09/22/2023 | APPROVED | MGIBSON |
| Note: 9/6/2023 - PREVIOUS INSPECTION NOTES Inspector Notes from Inspection 2075 BOTH GRAVITY SEWER AND U-SEWER TIE IN ARE APPROVED, C/M TO SCHEDUAL U-SEWER TIE IN FOR 7/10/23. NOT INSPECTORS OR BUILDING DEPARTMENT'S RESPONSIBILITY TO SCHEDUAL INSPECTIONS FOR CONTRACTORS THIS WASSECOND ATTEMPT FOR TUB SET INSPECTION, NOTES FROM LAST TIME WAS INDICATED IN NOTES WHAT IS REQUIRED FOR TUB SET INSPECTION | |||
| U-CROSS CONNECTION | 09/18/2023 | APPROVED - AS NOTED | LFITZGERALD |
| Note: has potable irrigation CURRENTLYwith PVB -SWITCHING OVER TO IRRIGATION METER-either way no cross connection | |||
| ROW- PROJECT STATUS | 09/06/2023 | APPROVED | EMADISON |
| Note: ** 09/06/23 MET WITH BUILDER AND GRADE CONTRACTOR | |||
| TUB SET | 09/06/2023 | Disapproved -FEE REQUIRED | MGIBSON |
| Note: Inspector Notes from Inspection 2075 BOTH GRAVITY SEWER AND U-SEWER TIE IN ARE APPROVED, C/M TO SCHEDUAL U-SEWER TIE IN FOR 7/10/23. NOT INSPECTORS OR BUILDING DEPARTMENT'S RESPONSIBILITY TO SCHEDUAL INSPECTIONS FOR CONTRACTORS THIS WASSECOND ATTEMPT FOR TUB SET INSPECTION, NOTES FROM LAST TIME WAS INDICATED IN NOTES WHAT IS REQUIRED FOR TUB SET INSPECTION | |||
| ROW- PROJECT STATUS | 09/05/2023 | CANCELLED BY INSPECTOR | GBERTOLA |
| Note: MEETING WITH THE BUILDER | |||
| ROW- PROJECT STATUS | 08/24/2023 | APPROVED | GBERTOLA |
| Note: During the meeting with Robert Gross, Ed Madison, and the builder, we discussed ways to reduce the slope on the apron. | |||
| ROW- PRE-APRON (PRE-POUR) | 08/17/2023 | APPROVED - AS NOTED | EMADISON |
| Note: ** 08/17/23 READY TO SET PAVERS _____________________________________________________________________________________________________________________ 8/11/2023 - PREVIOUS INSPECTION NOTES ** ** 08/11/23 READY TO POUR APRON, PAVER RESTRAINTS ** At the time of the inspection all minimum city requirements were met. It is the builders responsibiliy to ensure that nothing changes after this Inspection is approved. ** Sec.900.04C Residential driveways shall be constructed using material with a minimum of three thousand pounds (3,000 Ibs.) per square inch with Fiber or wire mesh. ** SCHEDULE NEXT PRE-POUR INSPECTION ONCE PAVER BASE HAS BEEN SPREAD AND COMPACTED ** DO NOT SET ANY PAVERS UNTIL THE NEXT PRE-POUR INSPECTION HAS BEEN APPROVED _____________________________________________________________________________________________________________________ _________________________________________________________________________________________________________________________ 8/11/2023 - PREVIOUS INSPECTION NOTES ** 08/11/23 UNABLE TO TO CONDUCT INSPECTION TRAILER AND TRUCK IN FRONT OF INSPECTION AREA DID NOT SEE ANYONE _____________________________________________________________________________________________________________________________ 8/10/2023 - PREVIOUS INSPECTION NOTES THERE NO PAVER DETAIL IN THE PERMIT NEED TO UPLOAD THE PAVER DETAIL SO WE CAN INSPECTION DRIVEWAY PROPERLY | |||
| ROW- PAVER RESTRAINTS | 08/17/2023 | APPROVED | EMADISON |
| ROW- PAVER RESTRAINTS | 08/11/2023 | APPROVED | EMADISON |
| Note: ** ** 08/11/23 READY TO POUR APRON, PAVER RESTRAINTS ** At the time of the inspection all minimum city requirements were met. It is the builders responsibiliy to ensure that nothing changes after this Inspection is approved. ** Sec.900.04C Residential driveways shall be constructed using material with a minimum of three thousand pounds (3,000 Ibs.) per square inch with Fiber or wire mesh. | |||
| ROW- PRE-APRON (PRE-POUR) | 08/11/2023 | Disapproved - NO FEE | EMADISON |
| Note: ** 08/11/23 UNABLE TO TO CONDUCT INSPECTION TRAILER AND TRUCK IN FRONT OF INSPECTION AREA DID NOT SEE ANYONE _____________________________________________________________________________________________________________________________ 8/10/2023 - PREVIOUS INSPECTION NOTES THERE NO PAVER DETAIL IN THE PERMIT NEED TO UPLOAD THE PAVER DETAIL SO WE CAN INSPECTION DRIVEWAY PROPERLY | |||
| ROW- PRE-APRON (PRE-POUR) | 08/11/2023 | PARTIALLY APPROVED | EMADISON |
| Note: ** ** 08/11/23 READY TO POUR APRON, PAVER RESTRAINTS ** At the time of the inspection all minimum city requirements were met. It is the builders responsibiliy to ensure that nothing changes after this Inspection is approved. ** Sec.900.04C Residential driveways shall be constructed using material with a minimum of three thousand pounds (3,000 Ibs.) per square inch with Fiber or wire mesh. ** SCHEDULE NEXT PRE-POUR INSPECTION ONCE PAVER BASE HAS BEEN SPREAD AND COMPACTED ** DO NOT SET ANY PAVERS UNTIL THE NEXT PRE-POUR INSPECTION HAS BEEN APPROVED _____________________________________________________________________________________________________________________ _________________________________________________________________________________________________________________________ 8/11/2023 - PREVIOUS INSPECTION NOTES ** 08/11/23 UNABLE TO TO CONDUCT INSPECTION TRAILER AND TRUCK IN FRONT OF INSPECTION AREA DID NOT SEE ANYONE _____________________________________________________________________________________________________________________________ 8/10/2023 - PREVIOUS INSPECTION NOTES THERE NO PAVER DETAIL IN THE PERMIT NEED TO UPLOAD THE PAVER DETAIL SO WE CAN INSPECTION DRIVEWAY PROPERLY | |||
| ROW- PRE-APRON (PRE-POUR) | 08/10/2023 | Disapproved -FEE REQUIRED | PFLANAGAN |
| Note: THERE NO PAVER DETAIL IN THE PERMIT NEED TO UPLOAD THE PAVER DETAIL SO WE CAN INSPECTION DRIVEWAY PROPERLY | |||
| ELECTRIC - EARLY POWER | 07/13/2023 | APPROVED - AS NOTED | AGAETANO |
| Note: 7/11/2023 - PREVIOUS INSPECTION NOTES 6/30/2023 - PREVIOUS INSPECTION NOTES cancelled per Holly via text 07-11-2023 Right front garage soffit outlet not safe off. 07-13-2023 FPL notified at 12:12pm | |||
| ELECTRIC - EARLY POWER | 07/11/2023 | Disapproved - NO FEE | AGAETANO |
| Note: 6/30/2023 - PREVIOUS INSPECTION NOTES cancelled per Holly via text 07-11-2023 Right front garage soffit outlet not safe off. | |||
| U - SEWER TIE IN | 07/10/2023 | APPROVED | MGIBSON |
| GRAVITY SEWER TEST | 07/07/2023 | APPROVED - AS NOTED | MGIBSON |
| Note: BOTH GRAVITY SEWER AND U-SEWER TIE IN ARE APPROVED, C/M TO SCHEDUAL U-SEWER TIE IN FOR 7/10/23. NOT INSPECTORS OR BUILDING DEPARTMENT'S RESPONSIBILITY TO SCHEDUAL INSPECTIONS FOR CONTRACTORS | |||
| ELECTRIC FINAL | 06/30/2023 | CANCELLED BY APPLICANT | LMILLER |
| Note: cancelled by Holly via phone conversation | |||
| ELECTRIC - EARLY POWER | 06/30/2023 | CANCELLED BY APPLICANT | LMILLER |
| Note: cancelled per Holly via text | |||
| LATH/BRICK/ WATER BARRIER | 05/19/2023 | APPROVED - AS NOTED | AGAETANO |
| Note: 05-19-2023 Entry on second floor needs additional staples. | |||
| INSULATION | 05/05/2023 | APPROVED | TSTAUFFACHER |
| Note: 5/3/2023 - PREVIOUS INSPECTION NOTES 05/03/2023- Ok to hang drywall in house except the exterior wall in downstairs front left room. Repair was not completed per engineering plan. call back in when repair is complete and window installed 4/21/2023 - PREVIOUS INSPECTION NOTES 04/21/2023-- strutural portion of house removed at far left window, solid poured cell has been compromised. Provide an engineer report for repair. Window sill not installed. DO NOT DRYWALL PRIOR TO THIS. 4/14/2023 - PREVIOUS INSPECTION NOTES 4/13/2023 - PREVIOUS INSPECTION NOTES From all rough: Add protection plates at stairs, hall and back bath Missing fire block at master bath/garage wall Fir out wall where service cable goes down exterior wall Move AC trunk line out of conditioned space in upstairs closet 04-14 2023 1. Protection plates not visible at back bath. 2. Trunk line not relocated away from conditioned space in upstarirs closet. 3. Front left window not installed. No covering for insulation. 4. SGD not covered for insulation. 5. Master bed dbl door missing window. Note to superintendent. Great room large rectangle window broken. | |||
| INSULATION | 05/03/2023 | PARTIALLY APPROVED | TSTAUFFACHER |
| Note: 05/03/2023- Ok to hang drywall in house except the exterior wall in downstairs front left room. Repair was not completed per engineering plan. call back in when repair is complete and window installed 4/21/2023 - PREVIOUS INSPECTION NOTES 04/21/2023-- strutural portion of house removed at far left window, solid poured cell has been compromised. Provide an engineer report for repair. Window sill not installed. DO NOT DRYWALL PRIOR TO THIS. 4/14/2023 - PREVIOUS INSPECTION NOTES 4/13/2023 - PREVIOUS INSPECTION NOTES From all rough: Add protection plates at stairs, hall and back bath Missing fire block at master bath/garage wall Fir out wall where service cable goes down exterior wall Move AC trunk line out of conditioned space in upstairs closet 04-14 2023 1. Protection plates not visible at back bath. 2. Trunk line not relocated away from conditioned space in upstarirs closet. 3. Front left window not installed. No covering for insulation. 4. SGD not covered for insulation. 5. Master bed dbl door missing window. Note to superintendent. Great room large rectangle window broken. | |||
| INSULATION | 04/21/2023 | Disapproved - NO FEE | TSTAUFFACHER |
| Note: 04/21/2023-- strutural portion of house removed at far left window, solid poured cell has been compromised. Provide an engineer report for repair. Window sill not installed. DO NOT DRYWALL PRIOR TO THIS. 4/14/2023 - PREVIOUS INSPECTION NOTES 4/13/2023 - PREVIOUS INSPECTION NOTES From all rough: Add protection plates at stairs, hall and back bath Missing fire block at master bath/garage wall Fir out wall where service cable goes down exterior wall Move AC trunk line out of conditioned space in upstairs closet 04-14 2023 1. Protection plates not visible at back bath. 2. Trunk line not relocated away from conditioned space in upstarirs closet. 3. Front left window not installed. No covering for insulation. 4. SGD not covered for insulation. 5. Master bed dbl door missing window. Note to superintendent. Great room large rectangle window broken. | |||
| TUB SET | 04/21/2023 | Disapproved - NO FEE | MGIBSON |
| Note: TUB NOT SET, TUB INSPECTION REQIRES TUP SET AT FINAL INSPECTION FOR WATER TO BE IN TUB WITH VALVE IN PLACE AND WASTE HOOKED UP TO CONNECTION | |||
| INSULATION | 04/14/2023 | Disapproved -FEE REQUIRED | AGAETANO |
| Note: 4/13/2023 - PREVIOUS INSPECTION NOTES From all rough: Add protection plates at stairs, hall and back bath Missing fire block at master bath/garage wall Fir out wall where service cable goes down exterior wall Move AC trunk line out of conditioned space in upstairs closet 04-14 2023 1. Protection plates not visible at back bath for inspection. 2. Trunk line not relocated away from conditioned space in upstarirs closet. 3. Front left window not installed. No covering for insulation. 4. SGD not covered for insulation. 5. Master bed dbl door missing window. Note to superintendent. Great room large rectangle window broken. | |||
| INSULATION | 04/13/2023 | CANCELLED BY APPLICANT | AGAETANO |
| Note: From all rough: Add protection plates at stairs, hall and back bath Missing fire block at master bath/garage wall Fir out wall where service cable goes down exterior wall Move AC trunk line out of conditioned space in upstairs closet | |||
| ALL ROUGH | 04/03/2023 | APPROVED - AS NOTED | TSTAUFFACHER |
| Note: Add protection plates at stairs, hall and back bath Missing fire block at master bath/garage wall Fir out wall where service cable goes down exterior wall Move AC trunk line out of conditioned space in upstairs closet 3/20/2023 - PREVIOUS INSPECTION NOTES 1. 5' head at 2nd floor and ground floor not holding water. 2. All exterior doors. Fasteners are not located in the 1 1/4" part of the jambs. Install anchors in the correct location or provide manufacture specs for current fastener locations. 3. Exterior windows at the first floor are missing fasteners. Install fasteners starting appx 4" from the corners and 12" o.c. after that or provide manufacture install instructions. 4. Rear slider 1st and 2nd floor not installed. 5. Railing at 2nd floor balcony is still temporary. 6. Microwave / oven duct is to be sealed completely at all fittings. 7. Multiple nail plates for wiring need to be installed check all areas. 2nd floor pex at the shower needs a plate. 8. Shower liner not filled and under test. 9. Outlet box at the right side of the rear slider is over the box fill limit. 35 cu in max. 6- 14-2 and 2 14-3. 10. Plumbing vent lines are to be sloped toward drain and supported at 4' o.c. 11. Flex duct entering the registers are to be installed with a smooth transition multiple duct are install with 90 degree bends and being kinked. 12. Supply register at the 2nd floor is hanging in the trusses and not supported in the ceiling. 13. 3 Flex duct lines not completed in garage hanging down and are not terminated. Tub set inspection for 1st floor tub being added. INSPECTION STOPPED! | |||
| TIE BEAM / LINTEL | 04/03/2023 | APPROVED | TSTAUFFACHER |
| Note: This is for the retaining wall outside at sea wall. one at the all rough inspection of main house | |||
| FOOTER | 04/03/2023 | APPROVED | TSTAUFFACHER |
| ALL ROUGH | 03/20/2023 | Disapproved -FEE REQUIRED | JWALKER |
| Note: 1. 5' head at 2nd floor and ground floor not holding water. 2. All exterior doors. Fasteners are not located in the 1 1/4" part of the jambs. Install anchors in the correct location or provide manufacture specs for current fastener locations. 3. Exterior windows at the first floor are missing fasteners. Install fasteners starting appx 4" from the corners and 12" o.c. after that or provide manufacture install instructions. 4. Rear slider 1st and 2nd floor not installed. 5. Railing at 2nd floor balcony is still temporary. 6. Microwave / oven duct is to be sealed completely at all fittings. 7. Multiple nail plates for wiring need to be installed check all areas. 2nd floor pex at the shower needs a plate. 8. Shower liner not filled and under test. 9. Outlet box at the right side of the rear slider is over the box fill limit. 35 cu in max. 6- 14-2 and 2 14-3. 10. Plumbing vent lines are to be sloped toward drain and supported at 4' o.c. 11. Flex duct entering the registers are to be installed with a smooth transition multiple duct are install with 90 degree bends and being kinked. 12. Supply register at the 2nd floor is hanging in the trusses and not supported in the ceiling. 13. 3 Flex duct lines not completed in garage hanging down and are not terminated. Tub set inspection for 1st floor tub being added. INSPECTION STOPPED! | |||
| ALL ROUGH | 03/14/2023 | CANCELLED BY APPLICANT | WEB |
| FOOTER | 03/10/2023 | APPROVED | FWILLIS |
| Note: 3/9/2023 - PREVIOUS INSPECTION NOTES Left side of house footing re-bar does not meet min. 3" clearance from dirt to rebar. Dig out and call back in for inspection. | |||
| FOOTER | 03/09/2023 | Disapproved - NO FEE | TSTAUFFACHER |
| Note: Left side of house footing re-bar does not meet min. 3" clearance from dirt to rebar. Dig out and call back in for inspection. | |||
| ROOF VALLEY & METAL | 03/09/2023 | APPROVED | TSTAUFFACHER |
| Note: 2/28/2023 - PREVIOUS INSPECTION NOTES 5x5 installed and unable to verify strapping dimensions. remove 5x5 flashing and expose straps for inspection | |||
| WALL SHEATHING | 03/07/2023 | APPROVED | TSTAUFFACHER |
| Note: 2/28/2023 - PREVIOUS INSPECTION NOTES Seams are taped-unable to verify edge nailing-nails set too deep | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 03/07/2023 | APPROVED | TSTAUFFACHER |
| Note: 2/28/2023 - PREVIOUS INSPECTION NOTES Strapping missing between floors- no interior load bearing wall detail calling for header strappig-continious load path missing-inspection stopped | |||
| ROOF VALLEY & METAL | 02/28/2023 | Disapproved - NO FEE | TSTAUFFACHER |
| Note: 5x5 installed and unable to verify strapping dimensions. remove 5x5 flashing and expose straps for inspection | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 02/28/2023 | Disapproved - NO FEE | TSTAUFFACHER |
| Note: Strapping missing between floors- no interior load bearing wall detail calling for header strappig-continious load path missing-inspection stopped | |||
| WALL SHEATHING | 02/28/2023 | Disapproved - NO FEE | TSTAUFFACHER |
| Note: Seams are taped-unable to verify edge nailing-nails set too deep | |||
| ENGINEERS APPROVAL LETTER (OFFICE USE) | 02/27/2023 | APPROVED | JMUNSON |
| Note: Per letter submitted on 11/18/22 | |||
| ELEV CERT-FOUNDATION APPROVAL | 02/27/2023 | APPROVED | JMYERS |
| FOUND SURVEY APPROVED (OFFICE) | 01/05/2023 | APPROVED | TBAKER |
| TIE BEAM / LINTEL | 12/27/2022 | APPROVED | AGAETANO |
| MONOLITHIC SLAB | 12/13/2022 | APPROVED | AGAETANO |
| Note: 12/12/2022 - PREVIOUS INSPECTION NOTES Inspector Notes from Inspection 2280 11/21/2022 - PREVIOUS INSPECTION NOTES 11/18/2022 - PREVIOUS INSPECTION NOTES 11-18-2022 1. Contractor not ready. 2. Please expose down cells for inspections. 11-21-2022 Please expose down cells for inspections. 11-22-2022 Stemwall was installed prior to footing inspection approval. 12-12-22 1. PSL collumn footing depth not per plans 2. CLEARANCE ON REBAR FROM EARTH 3” FBC R404.1.3.3.7.4 all highlighted on nplans | |||
| MONOLITHIC SLAB | 12/12/2022 | Disapproved - NO FEE | LMILLER |
| Note: Inspector Notes from Inspection 2280 11/21/2022 - PREVIOUS INSPECTION NOTES 11/18/2022 - PREVIOUS INSPECTION NOTES 11-18-2022 1. Contractor not ready. 2. Please expose down cells for inspections. 11-21-2022 Please expose down cells for inspections. 11-22-2022 Stemwall was installed prior to footing inspection approval. 12-12-22 1. PSL collumn footing depth not per plans 2. CLEARANCE ON REBAR FROM EARTH 3” FBC R404.1.3.3.7.4 all highlighted on nplans | |||
| PLUMBING 1ST ROUGH UNDERGROUND | 12/07/2022 | APPROVED | MGIBSON |
| FOOTER | 11/22/2022 | APPROVED - AS NOTED | AGAETANO |
| Note: New inspection due to canceled inspection New inspection due to canceled inspection 11/4/2022 - PREVIOUS INSPECTION NOTES 11/3/2022 - PREVIOUS INSPECTION NOTES Inspector Notes from Inspection 2270 THIS IS A REINSPECTION NEED THE APPROVED DOCUMENTS ON SITE FOR INSPECTION 107.3,1. Please have the Approved Drawings on site for inspection. 07-25-2022 - Interior bearing footings not installed. Look for load bearing footings at slab inspection. 11-04-2022 1. Revised drawings not on site ( Aug 18 & 10 28). 2. Interior footing not complete. 3. Footing rebar at lanai not installed. 42 x 42. 4. Entry footing rebat not installed. 48" x 48" 5. Detail of step footing not indicated. Please have all approved drawings on site for future inspections. 11-22-2022 Stem wall was installed prior to footing inspection being approved. | |||
| STEM WALL FOUNDATION | 11/22/2022 | APPROVED - AS NOTED | AGAETANO |
| Note: 11/21/2022 - PREVIOUS INSPECTION NOTES 11/18/2022 - PREVIOUS INSPECTION NOTES 11-18-2022 1. Contractor not ready. 2. Please expose down cells for inspections. 11-21-2022 Please expose down cells for inspections. 11-22-2022 Stemwall was installed prior to footing inspection approval. | |||
| STEM WALL FOUNDATION | 11/21/2022 | Disapproved -FEE REQUIRED | AGAETANO |
| Note: 11/18/2022 - PREVIOUS INSPECTION NOTES 11-18-2022 1. Contractor not ready. 2. Please expose down cells for inspections. 11-21-2022 Please expose down cells for inspections. Over 4'. | |||
| STEM WALL FOUNDATION | 11/18/2022 | Disapproved - NO FEE | AGAETANO |
| Note: 11-18-2022 1. Contractor not ready. 2. Please expose down cells for inspections. 3. Please submit to the building department. Footer poured prior to stem wall. Penetrating sonar or X Ray accompanied by an approved engineer's letter stating that the work was completed in compliance with approved documents and current codes. 4. Engineering letter not approved. Need to resolve prior to stem wall inspection. | |||
| FOOTER | 11/18/2022 | CANCELLED BY APPLICANT | WEB |
| Note: 11/4/2022 - PREVIOUS INSPECTION NOTES 11/3/2022 - PREVIOUS INSPECTION NOTES Inspector Notes from Inspection 2270 THIS IS A REINSPECTION NEED THE APPROVED DOCUMENTS ON SITE FOR INSPECTION 107.3,1. Please have the Approved Drawings on site for inspection. 07-25-2022 - Interior bearing footings not installed. Look for load bearing footings at slab inspection. 11-04-2022 1. Revised drawings not on site ( Aug 18 & 10 28). 2. Interior footing not complete. 3. Footing rebar at lanai not installed. 42 x 42. 4. Entry footing rebat not installed. 48" x 48" 5. Detail of step footing not indicated. Please have all approved drawings on site for future inspections. | |||
| FOOTER | 11/18/2022 | CANCELLED BY APPLICANT | WEB |
| Note: New inspection due to canceled inspection 11/4/2022 - PREVIOUS INSPECTION NOTES 11/3/2022 - PREVIOUS INSPECTION NOTES Inspector Notes from Inspection 2270 THIS IS A REINSPECTION NEED THE APPROVED DOCUMENTS ON SITE FOR INSPECTION 107.3,1. Please have the Approved Drawings on site for inspection. 07-25-2022 - Interior bearing footings not installed. Look for load bearing footings at slab inspection. 11-04-2022 1. Revised drawings not on site ( Aug 18 & 10 28). 2. Interior footing not complete. 3. Footing rebar at lanai not installed. 42 x 42. 4. Entry footing rebat not installed. 48" x 48" 5. Detail of step footing not indicated. Please have all approved drawings on site for future inspections. | |||
| FOOTER | 11/04/2022 | Disapproved -FEE REQUIRED | AGAETANO |
| Note: 11/3/2022 - PREVIOUS INSPECTION NOTES Inspector Notes from Inspection 2270 THIS IS A REINSPECTION NEED THE APPROVED DOCUMENTS ON SITE FOR INSPECTION 107.3,1. Please have the Approved Drawings on site for inspection. 07-25-2022 - Interior bearing footings not installed. Look for load bearing footings at slab inspection. 11-04-2022 1. Revised drawings not on site ( Aug 18 & 10 28). 2. Interior footing not complete. 3. Footing rebar at lanai not installed. 42 x 42. 4. Entry footing rebat not installed. 48" x 48" 5. Detail of step footing not indicated. Please have all approved drawings on site for future inspections. | |||
| FOOTER | 11/03/2022 | CANCELLED BY APPLICANT | AGAETANO |
| Note: Inspector Notes from Inspection 2270 THIS IS A REINSPECTION NEED THE APPROVED DOCUMENTS ON SITE FOR INSPECTION 107.3,1. Please have the Approved Drawings on site for inspection. 07-25-2022 - Interior bearing footings not installed. Look for load bearing footings at slab inspection. | |||
| WATER METER INSTALLATION REQUEST | 08/25/2022 | APPROVED | CSTONE |
| GRAVITY SEWER TEST | 07/28/2022 | CANCELLED BY APPLICANT | WEB |
| PLUMBING 1ST ROUGH UNDERGROUND | 07/28/2022 | CANCELLED BY APPLICANT | WEB |
| FOOTER | 07/25/2022 | APPROVED - AS NOTED | AGAETANO |
| Note: THIS IS A REINSPECTION NEED THE APPROVED DOCUMENTS ON SITE FOR INSPECTION 107.3,1. Please have the Approved Drawings on site for inspection. 07-25-2022 - Interior bearing footings not installed. Look for load bearing footings at slab inspection. | |||
| FOOTER | 07/22/2022 | Disapproved - NO FEE | AGAETANO |
| Note: NEED THE APPROVED DOCUMENTS ON SITE FOR INSPECTION 107.3,1. Please have te Approved Drawings on site for inspection. |
Review History
| Department | Status | Date In | Date Out |
| MECH | COMPLETE | 10/04/2023 | 10/04/2023 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| PLFM | COMPLETE | 10/03/2023 | 10/03/2023 |
| Note: Released By: JORDAN MYERS, C.F.M - (386)986-4789 - JMYERS@PALMCOASTGOV.COM The Final elevation certificate has been approved. | |||
| MECH | HOLD | 10/03/2023 | 10/03/2023 |
| Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM 1. Square footage on heatloads do not match the house plans 2. Entire Energy Calc and heatload needs to be from Cetified Air Quality. (Active subcontractor). Parts cannot be from origional energy calc | |||
| PLFM | HOLD | 09/29/2023 | 09/29/2023 |
| Note: Held By: JORDAN MYERS, C.F.M - (386)986-4789 - JMYERS@PALMCOASTGOV.COM Repeat comment: A8 c needs to be N/A as does d, e, and f on the new form per the revised instructions from FEMA. A9 f needs to be N/A per the revised instructions from FEMA. Please remove the E from B4 as it is already stated in B5. | |||
| MECH | HOLD | 09/29/2023 | 10/02/2023 |
| Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Sizing of small unit is less than 80% sensible load of the house per R403.7.1.1 Exception 1 | |||
| PLFM | HOLD | 09/22/2023 | 09/27/2023 |
| Note: Held By: JORDAN MYERS, C.F.M - (386)986-4789 - JMYERS@PALMCOASTGOV.COM A new elevation certificate has been released by FEMA, please revise elevation certificate to be on the new form. A8 a, b, and c need to be N/A not 0. A9 b, and c may be 0 on the new form but not the one submitted. C2 c and h need to be N/A if there is no elevation. C2 d shows 9.24' on the Final Survey but is listed as 9.0' on the elevation certificate, which is correct? C2 f and g, there are grades lower and higher than the listed LAG and HAG from the elevation certificate shown on the Final Survey, please revise. All pages of the elevation certificate must be submitted, on the new form this is pages 2-8. | |||
| ZON | COMPLETE | 09/21/2023 | 09/21/2023 |
| Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 09/21/2023 | 09/21/2023 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 09/15/2023 | 09/15/2023 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| SW1 | COMPLETE | 09/15/2023 | 09/21/2023 |
| Note: Released By: GABRIEL BERTOLA - (386)986-7660 - GBERTOLA@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 09/15/2023 | 09/15/2023 |
| Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 08/31/2023 | 09/11/2023 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| BADMIN | INFORMATION | 08/29/2023 | 08/29/2023 |
| Note: Marked INFORMATION By: BARBIE BEMBRY - (386)986-3780 - BUILDINGDIVISION@PALMCOASTGOV.COM Documents/Files named incorrectly o Please rename your files in accordance with the naming convention outlined in our ‘document requirements’ located on the permit portal page http://docs.palmcoastgov.com/departments/building/online/document-requirements.pdf o It is important that all submittals follow the guidelines for efficient plan review and record retention accuracy. o You may add to your file name AFTER the above naming convention has been met. Examples Document type: Plans File name : Plans Document type: Foundation Survey File name: Foundation Survey Document type: Manufactures Specifications File Name: Pool Alarm Document type: Manufactures Specifications File Name: Generator | |||
| BLD | HOLD | 08/22/2023 | 08/28/2023 |
| Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM 1. Provide guard construction details including guard construction materials, guard design loads for both the guard and guard in-fill components, guard height, guard top and bottom rails, guard in-fill components materials, maximum openings in guards, complete guard attachment details to landings and stairs. R301.5, Table R301.5, R312.1.2, R312.1.3 2. Guards and deck access opening in guard provides access to pool. Guards must conform to pool barrier requirements (height, openings, climbability, self-closing and self-latching out swinging gate, etc.). Provide design for guards that complies with R4501.17.1.1. through R4501.17.1.14. As an alternative, if entire rear yard is enclosed by a fence that complies with R4501.17.1.1 through R4501.17.1.14 all doors and windows providing direct access from the home to the pool can be equipped with an exit alarm that complies with UL 2017 per R4501.17.1.9 or the pool can be provided with a permanently affixed pool alarm that conforms to ASTM Standard F2208. If you intend to use any of these alternatives, you will need to submit manufacturer's spec sheets indicating compliance with the referenced standards. 3. Stair handrail to be mounted on stair side of guards. As shown, handrail is on the outside of the proposed guard. R311.7.8 4. Stair handrail and guard to extend to the nosing of the lowest / first riser. As shown, both the guard and handrail do not extend to the nosing of the first riser. R311.7.8.2 5. Provide stair design live loads. R301.5 6. Stair attachment to landings are not to rely on nails subject to withdraw. Provide framing anchor / connectors other than nails. R 507.8 | |||
| ZON | COMPLETE | 08/14/2023 | 08/15/2023 |
| Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM | |||
| ZON | HOLD | 08/10/2023 | 08/11/2023 |
| Note: Held By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM Layout on revised landscape doesn't match. Must have foundation plantings wrapping corners with four along each side | |||
| ENGIN1 | COMPLETE | 08/08/2023 | 08/09/2023 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| SW1 | COMPLETE | 08/08/2023 | 08/10/2023 |
| Note: Released By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 08/08/2023 | 08/09/2023 |
| Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 04/25/2023 | 05/01/2023 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| BADMIN | INFORMATION | 04/18/2023 | 04/18/2023 |
| Note: Marked INFORMATION By: SCOTT THOMAS - - STHOMAS@PALMCOASTGOV.COM GAS INSPECTION CAN BE ADDED THROUGH PORTAL | |||
| PLFM | COMPLETE | 02/27/2023 | 02/27/2023 |
| Note: Released By: JORDAN MYERS, C.F.M - (386)986-2320 - JMYERS@PALMCOASTGOV.COM The Foundation elevation certificate has been approved. Please provide Final prior to receiving CO. | |||
| ENGIN1 | COMPLETE | 02/27/2023 | 02/27/2023 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 02/27/2023 | 02/27/2023 |
| Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM | |||
| PLFM | HOLD | 02/23/2023 | 02/23/2023 |
| Note: Held By: JORDAN MYERS, C.F.M - (386)986-2320 - JMYERS@PALMCOASTGOV.COM Foundation Survey is missing all flood zone information from the FEMA FIRMs and flood zone line, please revise. Elevation certificate: A1 should have the actual owner, not Hulbert Homes. Section D, there needs to be a signature and date on top of the seal. | |||
| PLFM | HOLD | 02/23/2023 | 02/23/2023 |
| Note: Held By: JORDAN MYERS, C.F.M - (386)986-2320 - JMYERS@PALMCOASTGOV.COM Foundation Survey is missing all flood zone information from the FEMA FIRMs and flood zone line, please revise. Elevation Certificate: Section D, there needs to be a signature and date on top of the seal inside the box. | |||
| ENGIN1 | COMPLETE | 01/04/2023 | 01/05/2023 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 01/04/2023 | 01/04/2023 |
| Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 11/18/2022 | 11/18/2022 |
| Note: Released By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM | |||
| BLD | HOLD | 11/15/2022 | 11/16/2022 |
| Note: Held By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM All comments below per the 2020 Florida Building Code PLAN REVIEW COMMENTS: 1. Provide a revised Foundation Plan showing the Stepped Footing and details for Footing FBC 107 | |||
| BLD | COMPLETE | 10/28/2022 | 10/28/2022 |
| Note: Released By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM | |||
| BADMIN | INFORMATION | 10/20/2022 | 10/20/2022 |
| Note: Marked INFORMATION By: SCOTT THOMAS - - STHOMAS@PALMCOASTGOV.COM PLANS MISSING DIGITAL SIGNATURE | |||
| BLD | COMPLETE | 08/18/2022 | 08/19/2022 |
| Note: Released By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 08/01/2022 | 08/02/2022 |
| Note: Released By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM | |||
| BLD | HOLD | 07/28/2022 | 07/29/2022 |
| Note: Held By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM All comments below per the 2020 Florida Building Code REVIEW COMMENTS: 1. Provide revision clouds showing the changes to the revised drawings. FBC [A] 107.3 | |||
| ZON | COMPLETE | 07/13/2022 | 07/13/2022 |
| Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM | |||
| ZON | HOLD | 07/11/2022 | 07/12/2022 |
| Note: Held By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM The setbacks should be clear to see please remove the numbers near by i need to make sure all sides are meeting the zoning setback please look at the right side of the house by the garage. Please do not provide the set back from fdrive way to the propert line i need the right corner of the garage to property line. please look at the highlighted area on the site plan submitted | |||
| PLFM | COMPLETE | 07/11/2022 | 07/11/2022 |
| Note: Released By: JORDAN MYERS, C.F.M - (386)986-2320 - JMYERS@PALMCOASTGOV.COM The construction elevation certificate has been approved. However, at foundation if the surveyor does not sign and date on top of the seal the EC will not be approved. | |||
| PLFM | HOLD | 07/07/2022 | 07/07/2022 |
| Note: Held By: JORDAN MYERS, C.F.M - (386)986-2320 - JMYERS@PALMCOASTGOV.COM The following comments are in regards to the elevation certificate: A9b needs to be N/A not 0. B9 needs to read 6.0'. C2a states the top of bottom floor at 21.0 feet while the site plan says 9.0. please clarify. C2b also notes the next higher floor at 33.0 feet when the maximum height for the building can only be 35'. Section D the surveyor needs to sign and date on top of their seal as well as in the spot designated. | |||
| ZON | HOLD | 07/07/2022 | 07/07/2022 |
| Note: Held By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM The setbacks soudl be clear to see please remove the numbers near by i need to make sure all sides aremeeting the zoning setback please look at the right side of the house by the garage. | |||
| SW1 | COMPLETE | 07/07/2022 | 07/07/2022 |
| Note: Released By: CONRAD TROHA - (386)986-4767 - CTROHA@PALMCOASTGOV.COM Planning / zoning stemwall, setbacks, landscape change Drainage is good | |||
| PLFM | HOLD | 06/28/2022 | 06/28/2022 |
| Note: Held By: JORDAN MYERS, C.F.M - (386)986-2320 - JMYERS@PALMCOASTGOV.COM According to the revised Site Plan submitted on 6/28/22, the structure does fall within the SFHA. Elevation certificates are required at construction drawings, foundation, and final. | |||
| ZON | HOLD | 06/28/2022 | 06/28/2022 |
| Note: Held By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM house does not meet setbacks SFR 2 ZONE Front 20' REAR-6.5' SIDES 7.5' Please adjust house accordingly to fit setbacks Please look at the left side of home set back listed on site plan are incorrect Landscape and site plan dont match. site plan, landscape. and floor plan must all match please look at driveway on landcape plan | |||
| ENGIN1 | COMPLETE | 06/28/2022 | 06/28/2022 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| SW1 | COMPLETE | 06/28/2022 | 07/07/2022 |
| Note: Released By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM | |||
| PLFM | HOLD | 06/22/2022 | 06/22/2022 |
| Note: Held By: JORDAN MYERS, C.F.M - (386)986-2320 - JMYERS@PALMCOASTGOV.COM Comments partially addressed. The flood zone line needs to be shown on the site plan so staff can determine if the structure or machinery falls within the SFHA. Please revise site plan to show flood zone lines from the FEMA FIRM. | |||
| ZON | HOLD | 06/22/2022 | 06/22/2022 |
| Note: Held By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM site plan does not match Landscape & floor plan. Please add the mechanical units to site plan accordingly. Site plan only shows one unit. | |||
| ELEC | COMPLETE | 06/22/2022 | 06/22/2022 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| SW1 | COMPLETE | 06/22/2022 | 06/27/2022 |
| Note: Released By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM | |||
| BADMIN | INFORMATION | 06/22/2022 | 06/22/2022 |
| Note: Marked INFORMATION By: SCOTT THOMAS - - STHOMAS@PALMCOASTGOV.COM 1. REMOVE 'PETERS-SHT, 2020-140 MPH DETAILS' FROM ALL FILE NAMES. ONLY RENAME TO 'CB2.SF.PDF, CB1.PDF, ...' | |||
| PLFM | HOLD | 06/02/2022 | 06/02/2022 |
| Note: Held By: JORDAN MYERS, C.F.M - (386)986-2320 - JMYERS@PALMCOASTGOV.COM Site Plan and Survey are missing all flood zone information from the FEMA FIRMs, please revise. Should the structure or any associated machinery fall within the SFHA, elevation certificates will be required at construction drawings, foundation, and final. | |||
| BLD | COMPLETE | 06/01/2022 | 06/08/2022 |
| Note: Released By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM | |||
| CUSVC | COMPLETE | 06/01/2022 | 06/03/2022 |
| Note: Released By: CYNTHIA SCHWEERS - - CSCHWEERS@PALMCOASSTGOV.COM | |||
| ELEC | HOLD | 06/01/2022 | 06/03/2022 |
| Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. Need correct outlet spacing in bed 2,4 and computer nook room. NEC 2017 210.52 2. Living space total on electric plan does not match the living space on floor plan 3. Need swicth and light outside of master bedroom. NEC 2017 210.70 4. Outlet in garage, laundry, bathroom, kitchen,outside need to be GFCI protected. NEC 2017 210.8 | |||
| ENGIN1 | COMPLETE | 06/01/2022 | 06/01/2022 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| LOCATE | COMPLETE | 06/01/2022 | 06/07/2022 |
| Note: Released By: CANDACE STONE - - CSTONE@PALMCOASTGOV.COM | |||
| MECH | COMPLETE | 06/01/2022 | 06/02/2022 |
| Note: Released By: CHRIS PISCITELLI - (386)986-3782 - CPISCITELLI@PALMCOASTGOV.COM | |||
| SW1 | HOLD | 06/01/2022 | 06/13/2022 |
| Note: Held By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM FFE of subject property are to be a minimum of 12” above the crown of the road. (B) Adjacent driveway culverts and drainage features: Site Plan must include the inverts ofadjacent developed property driveway culverts and any other drainage features within 100 feet ofthe property lines. An on-site, third order, easily identifiable benchmark referenced to NAVD 1988 (e.g.fire hydrant, nail in power pole.) Pavement nails will not be accepted as benchmarks. The road centerline (RCL) and edge of pavement (EOP) elevations for roadwaysadjacent to and along all property lines, including EOP in cul-de-sacs at 9, 12, and 3 O’clockposition. (C) The proposed elevations shall be shown at all locations of existing elevations per the topographic survey Unless specifically stated the subject lot must drain from back to front or a portion may be drained to an adjacent City drainage feature. The front property line/right away elevation are to be equal to or greater than the centerline of the road elevation Culvert material and size to be depicted. Typical is 17X13 CMP | |||
| ZON | HOLD | 06/01/2022 | 06/03/2022 |
| Note: Held By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM Site Plan: Provide all legal information including map panel # and flood zones AE & X 0.2 % Provide driveway and sidewalk width and materials. Provide all setbacks Front, side, and rear from home to property line. Please eliminate some information to make the site plan clearer as it's too busy and hard to make out. Please remove the pool from site plan and from landscape plan and floor plan If driveway is Pavers you will need to fill out ROW agreement signed and notarized by all owners. Landscape plan: must match site plan and floor plan and landscape plan. All three must match the area in front of home looks different on landscape plan and please remove the pool. Landscape plan shows three mechanical area two on site plan and three on landscap plan please correct that. Elevation plan: Rear and front of home need full banding Banding around Windows and doors All windows and doors facing public right of way must have banding Provide total height of home | |||
| SWALE | COMPLETE | 06/01/2022 | 08/17/2022 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| PLAN REVIEW - REVISION | ¤32.50 | 10/17/2023 |
| PLAN REVIEW - REVISION | ¤65.00 | 10/17/2023 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 10/17/2023 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 10/17/2023 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 10/17/2023 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 10/17/2023 |
| CONTRACTOR CHANGE | ¤20.00 | 10/17/2023 |
| CONTRACTOR CHANGE | ¤20.00 | 10/17/2023 |
| CONTRACTOR CHANGE | ¤20.00 | 10/17/2023 |
| CONTRACTOR CHANGE | ¤20.00 | 10/17/2023 |
| SW ENG REINSPECTION 20 | ¤20.00 | 10/17/2023 |
| SW ENG REINSPECTION 20 | ¤20.00 | 10/17/2023 |
| SW ENG REINSPECTION 20 | ¤20.00 | 10/17/2023 |
| SW ENG REINSPECTION 30 | ¤30.00 | 10/17/2023 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 02/27/2023 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 02/27/2023 |
| PLAN REVIEW - REVISION | ¤32.50 | 02/27/2023 |
| PLAN REVIEW - REVISION | ¤32.50 | 02/27/2023 |
| PLAN REVIEW - REVISION | ¤32.50 | 02/27/2023 |
| PLAN REVIEW - REVISION | ¤32.50 | 02/27/2023 |
| WATER-METER | ¤467.09 | 07/15/2022 |
| WATER- TURN ON | ¤25.00 | 07/15/2022 |
| WATER- TURN ON | ¤25.00 | 07/15/2022 |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | 07/15/2022 |
| INSPECTION - RESIDENTIAL | ¤1,925.00 | 07/15/2022 |
| PLAN REVIEW - RESIDENTIAL | ¤546.00 | 07/15/2022 |
| CONNECTION FEES | ¤1,077.88 | 07/15/2022 |
| 3% FIRE IMPACT FEE CREDIT | (¤11.66) | 07/15/2022 |
| IMPACT FEE FIRE | ¤388.65 | 07/15/2022 |
| IMPACT FEE PARKS | ¤1,455.13 | 07/15/2022 |
| IMPACT FEE SCHOOL | ¤3,600.00 | 07/15/2022 |
| IMPACT FEE TRANSPORTATION | ¤1,764.00 | 07/15/2022 |
| WATER -IRRIGATION INSPECTION | ¤25.00 | 07/15/2022 |
| WATER -IRRIGATION INSPECTION | ¤25.00 | 07/15/2022 |
| 3% PARKS IMPACT FEE CREDIT | (¤43.65) | 07/15/2022 |
| SURCHARGE FS 533.721 | ¤20.36 | 07/15/2022 |
| SURCHARGE - FS 468.631 | ¤30.54 | 07/15/2022 |
| SW ENG - FOUNDATION SURVEY | ¤20.00 | 07/15/2022 |
| SW ENG INSPECTION 80 | ¤80.00 | 07/15/2022 |
| SW ENG PRE APRON | ¤30.00 | 07/15/2022 |
| SW ENG - REVIEW 20 | ¤20.00 | 07/15/2022 |
| SW ENG RES REVIEW 200 | ¤200.00 | 07/15/2022 |
| 3% TRANS IMPACT FEE CREDIT | (¤52.92) | 07/15/2022 |
| SEWER INSPECTION | ¤25.00 | 07/15/2022 |
| SEWER CAPITAL FACILITY | ¤4,939.76 | 07/15/2022 |
| WATER CAPITAL FACILITY FEE | ¤3,626.50 | 07/15/2022 |
| SITE PLAN 30 | ¤30.00 | 07/15/2022 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤20,905.18 |