Permit #2022060339

Permit Details

Status: COED

Parcel Id: 07-11-31-7023-00210-0110
CONDITIONED SPACE: 2170 sqft
OPENED PORCH (WITH ROOF) : 114 sqft
OPENED PORCH (WITH ROOF) : 497 sqft
GARAGE: 473 sqft
Total Square Footage: 3254 sqft
Block: 00210
Subdivision: 2191 - SECTION 23-WYNNFIELD
Job Phone: 386-237-5837
Location Address: 62 WHITTINGTON DR
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 11/03/2022
NOC: RECORDED
Applicant name: MARSEL GILMANSHIN
Owner: LEONOVA LARISA

Address

6 COCHRAN LANE

PALM COAST, FL 32137

Lot: 0110
Contracted Stated Job Value: ¤364,000.00
Job Description: Single Family Residence
Type: CN

Contractor

GILMANS DEVELOPMENT CORP
Status Location Address State License Number Phone
ACTIVE

4873 PALM COAST PARKWAY NW #4

PALM COAST, FL 32137

CBC1263180 (Exp: 08/31/2026) 386-237-5837

Sub Contractors

FERNANDO MEZA SR
Status Location Address State License Number Phone
ACTIVE

457 CHELSEA PLACE AVE

ORMOND BEACH, FL 32174

EC13003906 (Exp: 08/31/2026) 386-241-5211
ALEKSANDR A KATKO
Status Location Address State License Number Phone
ACTIVE

130 HARRISON RD

, 0

CFC1431723 (Exp: 08/31/2026) 386-341-3800
JUAN CARLOS GONZALEZ
Status Location Address State License Number
ACTIVE

1328 COUNTY ROAD 308

CRESCENT CITY, FL 32112

RF11067806 (Exp: 08/31/2027)
MARSEL GILMANSHIN
Status Location Address State License Number Phone
ACTIVE

4873 PALM COAST PARKWAY NW #4

PALM COAST, FL 32137

CBC1263180 (Exp: 08/31/2026) 386-237-5837
RUSLAN KHUSNIYAROV
Status Location Address State License Number
INACTIVE

74 EDWARD DR

PALM COAST, FL 32164

CAC1822489 (Exp: 08/31/2026)

Inspection History

Type Request Date Result Inspector
BLD - BUILDING FINAL 05/02/2025 FINAL APPROVED MCONTRYMAN
Note: 5/1/2025 - PREVIOUS INSPECTION NOTES 5/1/25 1. E-cals have not been approved by Building Department FBC (A)107.4 2. Sch 40 caps required on back lani for future plumbing 3. Can lights must be fire rated in garage FBC R302.6 4. AHU breaker oversized FBCR M1303.1 4/28/2025 - PREVIOUS INSPECTION NOTES 1. E-cals dont match the equipment that was installed FBC (A)107.4 2. Water heater requires a shut off 3. AHU heater sticker not marked to check proper breaker size FBCR M1303.1 4. Kitchen sink is missing p-trap 5. Kitchen sink missing auto vent 6. Dishwasher missing water hammer arrester FBCR P2903.5 7. Future plumbing lines out side require a sch 40 cap (drain) 8. ODU requires 4 tie downs FBC M1401.1 9. All sink must be hard piped flex pipe is not approved per manufacturer spec 10. Can lights in garage must be fire rated FBC R302.6 11. ODU plastic box for power must have an approved seal for unuesd opening NEC 110.12 12. Dishwasher drain line is required to be supported up FBCR P2717.2
BLD - BUILDING FINAL 05/01/2025 Disapproved -FEE REQUIRED MKRASKI
Note: 5/1/25 1. E-cals have not been approved by Building Department FBC (A)107.4 2. Sch 40 caps required on back lani for future plumbing 3. Can lights must be fire rated in garage FBC R302.6 4. AHU breaker oversized FBCR M1303.1 4/28/2025 - PREVIOUS INSPECTION NOTES 1. E-cals dont match the equipment that was installed FBC (A)107.4 2. Water heater requires a shut off 3. AHU heater sticker not marked to check proper breaker size FBCR M1303.1 4. Kitchen sink is missing p-trap 5. Kitchen sink missing auto vent 6. Dishwasher missing water hammer arrester FBCR P2903.5 7. Future plumbing lines out side require a sch 40 cap (drain) 8. ODU requires 4 tie downs FBC M1401.1 9. All sink must be hard piped flex pipe is not approved per manufacturer spec 10. Can lights in garage must be fire rated FBC R302.6 11. ODU plastic box for power must have an approved seal for unuesd opening NEC 110.12 12. Dishwasher drain line is required to be supported up FBCR P2717.2
BLD - BUILDING FINAL 04/28/2025 Disapproved - NO FEE MKRASKI
Note: 1. E-cals dont match the equipment that was installed FBC (A)107.4 2. Water heater requires a shut off 3. AHU heater sticker not marked to check proper breaker size FBCR M1303.1 4. Kitchen sink is missing p-trap 5. Kitchen sink missing auto vent 6. Dishwasher missing water hammer arrester FBCR P2903.5 7. Future plumbing lines out side require a sch 40 cap (drain) 8. ODU requires 4 tie downs FBC M1401.1 9. All sink must be hard piped flex pipe is not approved per manufacturer spec 10. Can lights in garage must be fire rated FBC R302.6 11. ODU plastic box for power must have an approved seal for unuesd opening NEC 110.12 12. Dishwasher drain line is required to be supported up FBCR P2717.2
BLD - BUILDING FINAL 04/24/2025 Disapproved -FEE REQUIRED CVANSTRAHLEN
Note: Please fix items before next inspection #1-E-cals do not match equitment install for AC and AH , please provide new e-Cals documents #2- light and exahusted switch for master bathroom can't no be behind the bathroom door #3- fire place in leaving room need a dedicateed circuit. (need a 15 amp breaker ) fire place factory amp is 12.5 #4-FBC [A] 105.7 -NEEDS PERMIT ON SITE #5-FBC-R . 302.6 seal all garage penetration , wall and ceiling ( low voltage wire AHU Plenum conduit )wall behind AH box missing drywall #6-1. ODU needs to be 3" from finished grade FBCR M1305.1.4.1
ROW - FINAL APRON (AFTER POUR) 04/21/2025 APPROVED TPOLACEK
Note: PIPE ELEVATION IS GOOD, CUTS ARE MADE, CULVERT CLEAR, HOT PATCH COMPLETE, AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED
ROW - STORMWATER FINAL 04/21/2025 APPROVED TPOLACEK
Note: AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED
U -UTILITY RESIDENTIAL FINAL 04/21/2025 APPROVED - AS NOTED LFITZGERALD
Note: lower sewe C/O riser PIPE-attach proper cap-send pic when done
ROW FIELD SURVEY /GRADING CERTIFICATION 04/17/2025 APPROVED TPOLACEK
Note: CORRECTIONS MADE. AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED 4/15/2025 - PREVIOUS INSPECTION NOTES 04/15/25 TPOLACEK*** SPOKE WITH CM ON PHONE AND EXPLAIND BOTH SIDE PROPERTY LINES NEEDS HIGHER BERM TO STOP DRAINAGE FROM NEGATIVLEY IMPACTING ADJOINING PROPERTIES. Top of the slope Sec 300.02.C(6) Sec 300.02.C(6)=The top of slope of “W” swales along the property lines shall be a minimum of 0.30 of a foot higher than the toe of slope.
ROW- FINAL SURVEY/GRADING CERTIFICATION 04/15/2025 APPROVED TPOLACEK
ROW FIELD SURVEY /GRADING CERTIFICATION 04/15/2025 Disapproved - NO FEE TPOLACEK
Note: 04/15/25 TPOLACEK*** SPOKE WITH CM ON PHONE AND EXPLAIND BOTH SIDE PROPERTY LINES NEEDS HIGHER BERM TO STOP DRAINAGE FROM NEGATIVLEY IMPACTING ADJOINING PROPERTIES. Top of the slope Sec 300.02.C(6) Sec 300.02.C(6)=The top of slope of “W” swales along the property lines shall be a minimum of 0.30 of a foot higher than the toe of slope.
ELECTRIC - EARLY POWER 04/07/2025 APPROVED - AS NOTED MKRASKI
Note: Emailed FPL @ 2:40pm
ROW- PRE-APRON (PRE-POUR) 03/24/2025 APPROVED TPOLACEK
Note: AT THE TIME OF THE INSPECTION CULVERT PIPE IS GOOD IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD DOUBLE CHECK CULVERT ELEVATIONS MAKE SURE TO USE 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. CONTRACTORS WILL BE NOTIFIED WHEN TICKETS WILL BE REQUIRED WITH AN EMAIL BLAST.THE FOLLOWING IS CURRENTLY FOR INFORMATION ONLY: TICKET OF CONCRETE MIX DESIGN SHALL BE UPLOADED INTO PERMIT PORTAL. 8.a. IF FIBERGLASS OPTION IS USED, DOCUMENTATION OF THE ( FRC) CONTAINING THE FIBERGLASS MUST BE ATTACHED TO THE PERMIT PRIOR TO REQUESTING AN AFTER-POUR INSPECTION. 8.b. IF MESH OPTION IS USED, IT SHALL BE IN PLACE AT THE TIME OF THE PRE-POUR.
U - SEWER TIE IN 02/20/2025 APPROVED - AS NOTED MGIBSON
Note: THIS WAS ADDED BY INSPECTOR
GRAVITY SEWER TEST 02/20/2025 APPROVED - AS NOTED MGIBSON
Note: U-SEWER TIE IN IS ALSO APPROVED
INSULATION 02/03/2025 APPROVED MKRASKI
Note:
PEP TANK INSTALLATION REQUEST 02/03/2025 APPROVED CBOWERMASTER
LATH/BRICK/ WATER BARRIER 01/22/2025 APPROVED - AS NOTED MKRASKI
Note: 1. No dumpster on site FBC 3302.2 2. Silt fence must be kept in orginal condition FBC 3307.1
INSULATION 01/13/2025 CANCELLED BY APPLICANT MKRASKI
Note: Inspector Notes from Inspection 2420 1/6/25 1. Failed 5' head pressure test 2. Mech duct work does not match duck work layout on E-cals 3. Revision required for MI windows installed 4. Seal elec chase @ island Make ALL repairs before calling in insulation 12/31/2024 - PREVIOUS INSPECTION NOTES 12/31/24 1. Previous items not repaired FBC [A] 110.6 2. Windows do not match product approval sheet FBC [A]107.4 3. Address not visible form street FBC 319.1 4. Front door required solid blocking gaps exceeding 1/4'' max FBCR 609.1 5. E-cals duct layout do not match what is installed FBC [A]107.4 6. Exterior swing doors not installed to check anchors and gaps FBCR 609.1 7. Failed 5' head pressure FBCR P2503.7 8. Crushed supply ducts FBC M1301.3 9. Elec chase needs to be sealed at slab FBC R402.4.1.1 10. Exhaust fans require 2 points of attachment FBCR M1604.4.1 11. All a/c registers require seal FBC R402.4.1.1 ***Make ALL repairs before calling in for re-inspection*** 12/19/2024 - PREVIOUS INSPECTION NOTES 1. Stickers have been removed from most windows 2. Product approval sheet does not match windows installed 3. No plans on site or E-cals FBC 107.3.1 4. No 50 lbs of pressure on supply lines FBCR P2503.5 5. Failed 5' head pressure test and tubs not filled to over flow FBCR P2503.7 6. Exhaust fan duct attachment requires two points of attachment FBCR M1604.4.1 7. All a/c registers require seal FBC R402.4.1.1 *** Insulation was already installed, Do not insulate untill after all rough has been approved per Building Dept. ***
ALL ROUGH 01/06/2025 APPROVED - AS NOTED MKRASKI
Note: 1/6/25 1. Failed 5' head pressure test 2. Mech duct work does not match duck work layout on E-cals 3. Revision required for MI windows installed 4. Seal elec chase @ island Make ALL repairs before calling in insulation 12/31/2024 - PREVIOUS INSPECTION NOTES 12/31/24 1. Previous items not repaired FBC [A] 110.6 2. Windows do not match product approval sheet FBC [A]107.4 3. Address not visible form street FBC 319.1 4. Front door required solid blocking gaps exceeding 1/4'' max FBCR 609.1 5. E-cals duct layout do not match what is installed FBC [A]107.4 6. Exterior swing doors not installed to check anchors and gaps FBCR 609.1 7. Failed 5' head pressure FBCR P2503.7 8. Crushed supply ducts FBC M1301.3 9. Elec chase needs to be sealed at slab FBC R402.4.1.1 10. Exhaust fans require 2 points of attachment FBCR M1604.4.1 11. All a/c registers require seal FBC R402.4.1.1 ***Make ALL repairs before calling in for re-inspection*** 12/19/2024 - PREVIOUS INSPECTION NOTES 1. Stickers have been removed from most windows 2. Product approval sheet does not match windows installed 3. No plans on site or E-cals FBC 107.3.1 4. No 50 lbs of pressure on supply lines FBCR P2503.5 5. Failed 5' head pressure test and tubs not filled to over flow FBCR P2503.7 6. Exhaust fan duct attachment requires two points of attachment FBCR M1604.4.1 7. All a/c registers require seal FBC R402.4.1.1 *** Insulation was already installed, Do not insulate untill after all rough has been approved per Building Dept. ***
ALL ROUGH 12/31/2024 Disapproved -FEE REQUIRED MKRASKI
Note: 12/31/24 1. Previous items not repaired FBC [A] 110.6 2. Windows do not match product approval sheet FBC [A]107.4 3. Address not visible form street FBC 319.1 4. Front door required solid blocking gaps exceeding 1/4'' max FBCR 609.1 5. E-cals duct layout do not match what is installed FBC [A]107.4 6. Exterior swing doors not installed to check anchors and gaps FBCR 609.1 7. Failed 5' head pressure FBCR P2503.7 8. Crushed supply ducts FBC M1301.3 9. Elec chase needs to be sealed at slab FBC R402.4.1.1 10. Exhaust fans require 2 points of attachment FBCR M1604.4.1 11. All a/c registers require seal FBC R402.4.1.1 ***Make ALL repairs before calling in for re-inspection*** 12/19/2024 - PREVIOUS INSPECTION NOTES 1. Stickers have been removed from most windows 2. Product approval sheet does not match windows installed 3. No plans on site or E-cals FBC 107.3.1 4. No 50 lbs of pressure on supply lines FBCR P2503.5 5. Failed 5' head pressure test and tubs not filled to over flow FBCR P2503.7 6. Exhaust fan duct attachment requires two points of attachment FBCR M1604.4.1 7. All a/c registers require seal FBC R402.4.1.1 *** Insulation was already installed, Do not insulate untill after all rough has been approved per Building Dept. ***
ALL ROUGH 12/19/2024 Disapproved -FEE REQUIRED MKRASKI
Note: 1. Stickers have been removed from most windows 2. Product approval sheet does not match windows installed 3. No plans on site or E-cals FBC 107.3.1 4. No 50 lbs of pressure on supply lines FBCR P2503.5 5. Failed 5' head pressure test and tubs not filled to over flow FBCR P2503.7 6. Exhaust fan duct attachment requires two points of attachment FBCR M1604.4.1 7. All a/c registers require seal FBC R402.4.1.1 *** Insulation was already installed, Do not insulate untill after all rough has been approved per Building Dept. *** ***Full re-inspection required***
WALL SHEATHING 11/22/2024 APPROVED MKRASKI
LATH/BRICK/ WATER BARRIER 11/22/2024 Disapproved -FEE REQUIRED MKRASKI
Note: 1. No porta jon on site FBC P311.1 2. No dumpster on site FBC 3302.2 3. Silt fence must be kept in orginal condition FBC 3307.1 4. All exterior penitrations and holes in block require water barrier and lath R402.4.1.1
ROOF VALLEY & METAL 06/27/2024 APPROVED FWILLIS
Note: Inspector Notes from Inspection 2460 6/17/24 1. CMU to load bearing wall not per detail 2. Load bearing wall not per detail missing blocking and SPs on every stud 3. Need Load bearing door opening deatil Check on next inspection 5/24/2024 - PREVIOUS INSPECTION NOTES 5/24/24 Make ALL previous notes repaired before calling in re-inspection, Look at detais for load bearing walls and load bearing to CMU attachment, NOT READY 5/22/2024 - PREVIOUS INSPECTION NOTES 05-22-2024 1. EJ02P at lanai missing truss plate. 2. T20 truss at lanai not fastened properly. 3. T01 strap not fastened properly. 4. Sheet 5 Isometric connection frame to CMU not installed as per plan. Check all areas. 5. Load bearing wall detail not on site. 6. Engineering and truss layout do not match. Framer on site. Contractor not ready. A complete inspection will be required for next inspection. DOCUMENTS MUST BE APPROVED AND KEPT ON SITE 107.3,1. AND SHALL BE OPEN TO INSPECTION BY THE BUILDING OFFICIAL 5/6/2024 - PREVIOUS INSPECTION NOTES 5/6/24 Please review all previous notes and make repairs before calling im re-inspection . 4/3/2024 - PREVIOUS INSPECTION NOTES 4/3/24 Make all previous repairs before calling in re-in spection, truss straps missing, Load bearing wall to CMU not per detail per new revison stopped inspection 3/21/2024 - PREVIOUS INSPECTION NOTES 3/19/24 1. Still no interior load bearing wall detail, detail needs to be submitted and approved by Building Dept. before calling in re-inspection 2. No Load bearing wall attachment to CMU detail, also needs a revision 3. Multiple truss straps still missing Stopped inspection make all repairs before calling in re-inspection Did not check engineering 3/8/2024 - PREVIOUS INSPECTION NOTES 3/8/24 All previous items must be repaired before calling in re-inspection 3/5/2024 - PREVIOUS INSPECTION NOTES 3/5/24 1. Multiple trusses missing straps check all 2. No interior load bearing wall detail 3. No truss enginnering on site 4. Job box needs to be installed in yard facing road with address 5. No dumpster on site, some trash still needs to be cleaned up Stopped inspection, not ready 2/29/2024 - PREVIOUS INSPECTION NOTES From previous inspection, Silt fence has not been installed, stopped inspection. Call in for re-inspection after repair has been made/ Clean up trash also
ROOF SHEATHING / BRACES/TIES/DOWN CELL 06/17/2024 APPROVED - AS NOTED MKRASKI
Note: 6/17/24 1. CMU to load bearing wall not per detail 2. Load bearing wall not per detail missing blocking and SPs on every stud 3. Need Load bearing door opening deatil Check on next inspection 5/24/2024 - PREVIOUS INSPECTION NOTES 5/24/24 Make ALL previous notes repaired before calling in re-inspection, Look at detais for load bearing walls and load bearing to CMU attachment, NOT READY 5/22/2024 - PREVIOUS INSPECTION NOTES 05-22-2024 1. EJ02P at lanai missing truss plate. 2. T20 truss at lanai not fastened properly. 3. T01 strap not fastened properly. 4. Sheet 5 Isometric connection frame to CMU not installed as per plan. Check all areas. 5. Load bearing wall detail not on site. 6. Engineering and truss layout do not match. Framer on site. Contractor not ready. A complete inspection will be required for next inspection. DOCUMENTS MUST BE APPROVED AND KEPT ON SITE 107.3,1. AND SHALL BE OPEN TO INSPECTION BY THE BUILDING OFFICIAL 5/6/2024 - PREVIOUS INSPECTION NOTES 5/6/24 Please review all previous notes and make repairs before calling im re-inspection . 4/3/2024 - PREVIOUS INSPECTION NOTES 4/3/24 Make all previous repairs before calling in re-in spection, truss straps missing, Load bearing wall to CMU not per detail per new revison stopped inspection 3/21/2024 - PREVIOUS INSPECTION NOTES 3/19/24 1. Still no interior load bearing wall detail, detail needs to be submitted and approved by Building Dept. before calling in re-inspection 2. No Load bearing wall attachment to CMU detail, also needs a revision 3. Multiple truss straps still missing Stopped inspection make all repairs before calling in re-inspection Did not check engineering 3/8/2024 - PREVIOUS INSPECTION NOTES 3/8/24 All previous items must be repaired before calling in re-inspection 3/5/2024 - PREVIOUS INSPECTION NOTES 3/5/24 1. Multiple trusses missing straps check all 2. No interior load bearing wall detail 3. No truss enginnering on site 4. Job box needs to be installed in yard facing road with address 5. No dumpster on site, some trash still needs to be cleaned up Stopped inspection, not ready 2/29/2024 - PREVIOUS INSPECTION NOTES From previous inspection, Silt fence has not been installed, stopped inspection. Call in for re-inspection after repair has been made/ Clean up trash also
ROOF SHEATHING / BRACES/TIES/DOWN CELL 05/24/2024 Disapproved -FEE REQUIRED MKRASKI
Note: 5/24/24 Make ALL previous notes repaired before calling in re-inspection, Look at detais for load bearing walls and load bearing to CMU attachment, NOT READY 5/22/2024 - PREVIOUS INSPECTION NOTES 05-22-2024 1. EJ02P at lanai missing truss plate. 2. T20 truss at lanai not fastened properly. 3. T01 strap not fastened properly. 4. Sheet 5 Isometric connection frame to CMU not installed as per plan. Check all areas. 5. Load bearing wall detail not on site. 6. Engineering and truss layout do not match. Framer on site. Contractor not ready. A complete inspection will be required for next inspection. DOCUMENTS MUST BE APPROVED AND KEPT ON SITE 107.3,1. AND SHALL BE OPEN TO INSPECTION BY THE BUILDING OFFICIAL 5/6/2024 - PREVIOUS INSPECTION NOTES 5/6/24 Please review all previous notes and make repairs before calling im re-inspection . 4/3/2024 - PREVIOUS INSPECTION NOTES 4/3/24 Make all previous repairs before calling in re-in spection, truss straps missing, Load bearing wall to CMU not per detail per new revison stopped inspection 3/21/2024 - PREVIOUS INSPECTION NOTES 3/19/24 1. Still no interior load bearing wall detail, detail needs to be submitted and approved by Building Dept. before calling in re-inspection 2. No Load bearing wall attachment to CMU detail, also needs a revision 3. Multiple truss straps still missing Stopped inspection make all repairs before calling in re-inspection Did not check engineering 3/8/2024 - PREVIOUS INSPECTION NOTES 3/8/24 All previous items must be repaired before calling in re-inspection 3/5/2024 - PREVIOUS INSPECTION NOTES 3/5/24 1. Multiple trusses missing straps check all 2. No interior load bearing wall detail 3. No truss enginnering on site 4. Job box needs to be installed in yard facing road with address 5. No dumpster on site, some trash still needs to be cleaned up Stopped inspection, not ready 2/29/2024 - PREVIOUS INSPECTION NOTES From previous inspection, Silt fence has not been installed, stopped inspection. Call in for re-inspection after repair has been made/ Clean up trash also
ROOF SHEATHING / BRACES/TIES/DOWN CELL 05/22/2024 Disapproved - NO FEE AGAETANO
Note: 05-22-2024 1. EJ02P at lanai missing truss plate. 2. T20 truss at lanai not fastened properly. 3. T01 strap not fastened properly. 4. Sheet 5 Isometric connection frame to CMU not installed as per plan. Check all areas. 5. Load bearing wall detail not on site. 6. Engineering and truss layout do not match. Framer on site. Contractor not ready. A complete inspection will be required for next inspection. DOCUMENTS MUST BE APPROVED AND KEPT ON SITE 107.3,1. AND SHALL BE OPEN TO INSPECTION BY THE BUILDING OFFICIAL 5/6/2024 - PREVIOUS INSPECTION NOTES 5/6/24 Please review all previous notes and make repairs before calling im re-inspection . 4/3/2024 - PREVIOUS INSPECTION NOTES 4/3/24 Make all previous repairs before calling in re-in spection, truss straps missing, Load bearing wall to CMU not per detail per new revison stopped inspection 3/21/2024 - PREVIOUS INSPECTION NOTES 3/19/24 1. Still no interior load bearing wall detail, detail needs to be submitted and approved by Building Dept. before calling in re-inspection 2. No Load bearing wall attachment to CMU detail, also needs a revision 3. Multiple truss straps still missing Stopped inspection make all repairs before calling in re-inspection Did not check engineering 3/8/2024 - PREVIOUS INSPECTION NOTES 3/8/24 All previous items must be repaired before calling in re-inspection 3/5/2024 - PREVIOUS INSPECTION NOTES 3/5/24 1. Multiple trusses missing straps check all 2. No interior load bearing wall detail 3. No truss enginnering on site 4. Job box needs to be installed in yard facing road with address 5. No dumpster on site, some trash still needs to be cleaned up Stopped inspection, not ready 2/29/2024 - PREVIOUS INSPECTION NOTES From previous inspection, Silt fence has not been installed, stopped inspection. Call in for re-inspection after repair has been made/ Clean up trash also
ROOF SHEATHING / BRACES/TIES/DOWN CELL 05/06/2024 Disapproved -FEE REQUIRED MKRASKI
Note: 5/6/24 Please review all previous notes and make repairs before calling im re-inspection . 4/3/2024 - PREVIOUS INSPECTION NOTES 4/3/24 Make all previous repairs before calling in re-in spection, truss straps missing, Load bearing wall to CMU not per detail per new revison stopped inspection 3/21/2024 - PREVIOUS INSPECTION NOTES 3/19/24 1. Still no interior load bearing wall detail, detail needs to be submitted and approved by Building Dept. before calling in re-inspection 2. No Load bearing wall attachment to CMU detail, also needs a revision 3. Multiple truss straps still missing Stopped inspection make all repairs before calling in re-inspection Did not check engineering 3/8/2024 - PREVIOUS INSPECTION NOTES 3/8/24 All previous items must be repaired before calling in re-inspection 3/5/2024 - PREVIOUS INSPECTION NOTES 3/5/24 1. Multiple trusses missing straps check all 2. No interior load bearing wall detail 3. No truss enginnering on site 4. Job box needs to be installed in yard facing road with address 5. No dumpster on site, some trash still needs to be cleaned up Stopped inspection, not ready 2/29/2024 - PREVIOUS INSPECTION NOTES From previous inspection, Silt fence has not been installed, stopped inspection. Call in for re-inspection after repair has been made/ Clean up trash also
ROOF SHEATHING / BRACES/TIES/DOWN CELL 04/03/2024 Disapproved -FEE REQUIRED MKRASKI
Note: 4/3/24 Make all previous repairs before calling in re-in spection, truss straps missing, Load bearing wall to CMU not per detail per new revison stopped inspection 3/21/2024 - PREVIOUS INSPECTION NOTES 3/19/24 1. Still no interior load bearing wall detail, detail needs to be submitted and approved by Building Dept. before calling in re-inspection 2. No Load bearing wall attachment to CMU detail, also needs a revision 3. Multiple truss straps still missing Stopped inspection make all repairs before calling in re-inspection Did not check engineering 3/8/2024 - PREVIOUS INSPECTION NOTES 3/8/24 All previous items must be repaired before calling in re-inspection 3/5/2024 - PREVIOUS INSPECTION NOTES 3/5/24 1. Multiple trusses missing straps check all 2. No interior load bearing wall detail 3. No truss enginnering on site 4. Job box needs to be installed in yard facing road with address 5. No dumpster on site, some trash still needs to be cleaned up Stopped inspection, not ready 2/29/2024 - PREVIOUS INSPECTION NOTES From previous inspection, Silt fence has not been installed, stopped inspection. Call in for re-inspection after repair has been made/ Clean up trash also
ROOF VALLEY & METAL 03/26/2024 CANCELLED BY APPLICANT WEB
ROOF SHEATHING / BRACES/TIES/DOWN CELL 03/21/2024 Disapproved -FEE REQUIRED MKRASKI
Note: 3/19/24 1. Still no interior load bearing wall detail, detail needs to be submitted and approved by Building Dept. before calling in re-inspection 2. No Load bearing wall attachment to CMU detail, also needs a revision 3. Multiple truss straps still missing Stopped inspection make all repairs before calling in re-inspection Did not check engineering 3/8/2024 - PREVIOUS INSPECTION NOTES 3/8/24 All previous items must be repaired before calling in re-inspection 3/5/2024 - PREVIOUS INSPECTION NOTES 3/5/24 1. Multiple trusses missing straps check all 2. No interior load bearing wall detail 3. No truss enginnering on site 4. Job box needs to be installed in yard facing road with address 5. No dumpster on site, some trash still needs to be cleaned up Stopped inspection, not ready 2/29/2024 - PREVIOUS INSPECTION NOTES From previous inspection, Silt fence has not been installed, stopped inspection. Call in for re-inspection after repair has been made/ Clean up trash also
ROOF SHEATHING / BRACES/TIES/DOWN CELL 03/08/2024 Disapproved -FEE REQUIRED MKRASKI
Note: 3/8/24 All previous items must be repaired before calling in re-inspection 3/5/2024 - PREVIOUS INSPECTION NOTES 3/5/24 1. Multiple trusses missing straps check all 2. No interior load bearing wall detail 3. No truss enginnering on site 4. Job box needs to be installed in yard facing road with address 5. No dumpster on site, some trash still needs to be cleaned up Stopped inspection, not ready 2/29/2024 - PREVIOUS INSPECTION NOTES From previous inspection, Silt fence has not been installed, stopped inspection. Call in for re-inspection after repair has been made/ Clean up trash also
ROOF SHEATHING / BRACES/TIES/DOWN CELL 03/05/2024 Disapproved -FEE REQUIRED MKRASKI
Note: 3/5/24 1. Multiple trusses missing straps check all 2. No interior load bearing wall detail 3. No truss enginnering on site 4. Job box needs to be installed in yard facing road with address 5. No dumpster on site, some trash still needs to be cleaned up Stopped inspection, not ready 2/29/2024 - PREVIOUS INSPECTION NOTES From previous inspection, Silt fence has not been installed, stopped inspection. Call in for re-inspection after repair has been made/ Clean up trash also
ROOF SHEATHING / BRACES/TIES/DOWN CELL 02/29/2024 Disapproved -FEE REQUIRED MKRASKI
Note: From previous inspection, Silt fence has not been installed, stopped inspection. Call in for re-inspection after repair has been made/ Clean up trash also
ELECTRIC TEMP POLE 01/08/2024 APPROVED RMARTIN
ELECTRIC TEMP POLE 01/08/2024 APPROVED - AS NOTED RMARTIN
Note: NEED TO INSTALL SILT FENCE BY NEXT INSPECTION
MONOLITHIC SLAB 04/10/2023 APPROVED MKRASKI
TIE BEAM / LINTEL 03/15/2023 APPROVED MKRASKI
FOUND SURVEY APPROVED (OFFICE) 02/22/2023 APPROVED TBAKER
MONOLITHIC SLAB 02/01/2023 APPROVED MKRASKI
PLUMBING 1ST ROUGH UNDERGROUND 01/31/2023 APPROVED MGIBSON
Note: 1/27/2023 - PREVIOUS INSPECTION NOTES 1/24/2023 - PREVIOUS INSPECTION NOTES NOT HOLDING 5' HEAD TEST 5' HEAD TEST STILL NOT HOLDING
PLUMBING 1ST ROUGH UNDERGROUND 01/27/2023 Disapproved - NO FEE MGIBSON
Note: 1/24/2023 - PREVIOUS INSPECTION NOTES NOT HOLDING 5' HEAD TEST 5' HEAD TEST STILL NOT HOLDING
PLUMBING 1ST ROUGH UNDERGROUND 01/24/2023 Disapproved -FEE REQUIRED MGIBSON
Note: NOT HOLDING 5' HEAD TEST AND NEED TO LIST CORRECT PLUMBING CONTRACTOR
WATER METER INSTALLATION REQUEST 12/16/2022 APPROVED CSTONE
Note: 11/22/2022 8:20:15 AM- PREVIOUS INSPECTION NOTES 11/17/2022 8:47:43 AM- PREVIOUS INSPECTION NOTES still clearing still clearing 11/21
WATER METER INSTALLATION REQUEST 11/21/2022 Disapproved -FEE REQUIRED CSTONE
Note: 11/17/2022 8:47:43 AM- PREVIOUS INSPECTION NOTES still clearing still clearing 11/21
WATER METER INSTALLATION REQUEST 11/15/2022 Disapproved - NO FEE CSTONE
Note: still clearing

Review History

Department Status Date In Date Out
MECH COMPLETE 05/01/2025 05/01/2025
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
BLD COMPLETE 01/23/2025 01/29/2025
Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM
BLD HOLD 01/13/2025 01/17/2025
Note: Held By: PETER KNAPIK - - PKNAPIK@PALMCOASTGOV.COM 1. FL# 18644 and FL# 41866, neither are Single/Double hung windows. Please revise.
MECH COMPLETE 08/20/2024 08/21/2024
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
MECH HOLD 08/14/2024 08/19/2024
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM 1. Provide duct layout signed by the AC Contractor (Page is blank. Need duct layout) second request
MECH HOLD 08/06/2024 08/12/2024
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM 1. Provide duct layout signed by the AC Contractor 2. List mechanical subcontractor on portal
BLD COMPLETE 07/30/2024 08/01/2024
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
BLD COMPLETE 05/14/2024 05/20/2024
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM KS
BLD COMPLETE 03/26/2024 04/01/2024
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
ENGIN1 COMPLETE 02/21/2023 02/22/2023
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
ZON COMPLETE 02/21/2023 02/22/2023
Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM
ENGIN1 HOLD 02/15/2023 02/15/2023
Note: Held By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM Elevation of slab on foundation survey is 1.5' +/- higher than approved site plan. Please revise appropriate drawing and resubmit.
ZON COMPLETE 02/15/2023 02/15/2023
Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM
BLD COMPLETE 02/14/2023 02/15/2023
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
ENGIN1 COMPLETE 02/14/2023 02/14/2023
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
ZON COMPLETE 02/14/2023 02/14/2023
Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM
ENGIN1 COMPLETE 01/11/2023 01/12/2023
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
SW1 COMPLETE 01/11/2023 01/19/2023
Note: Released By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM
ZON COMPLETE 01/11/2023 01/11/2023
Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM
ZON COMPLETE 07/07/2022 07/07/2022
Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM
ZON HOLD 06/28/2022 06/28/2022
Note: Held By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM add a/c to floor plan and landscap plan they continue to not mach
ENGIN1 COMPLETE 06/27/2022 06/28/2022
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
SW1 COMPLETE 06/27/2022 07/07/2022
Note: Released By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM
ZON HOLD 06/21/2022 06/21/2022
Note: Held By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM Repeat Comment: On site plan submitted the A/C pad is missing. Please include that in your plans If your mechanical equipment is encroaching then you will need to fill out the 2' encroachment agreement
ELEC COMPLETE 06/21/2022 06/21/2022
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
ELEC COMPLETE 06/09/2022 06/09/2022
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
BLD COMPLETE 06/06/2022 06/09/2022
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
CUSVC COMPLETE 06/06/2022 06/07/2022
Note: Released By: CYNTHIA SCHWEERS - - CSCHWEERS@PALMCOASSTGOV.COM
ELEC HOLD 06/06/2022 06/07/2022
Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM Submit electric load calcs
ENGIN1 COMPLETE 06/06/2022 06/06/2022
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
LOCATE COMPLETE 06/06/2022 06/13/2022
Note: Released By: CANDACE STONE - - CSTONE@PALMCOASTGOV.COM
MECH COMPLETE 06/06/2022 06/07/2022
Note: Released By: CHRIS PISCITELLI - (386)986-3782 - CPISCITELLI@PALMCOASTGOV.COM
SW1 COMPLETE 06/06/2022 06/13/2022
Note: Released By: EDWARD MADISON - - EMADISON@PALMCOASTGOV.COM
ZON HOLD 06/06/2022 06/08/2022
Note: Held By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM On site plan submitted the A/C pad is missing. Please include that in your plans If your mechanical equipment is encroaching then you will need to fill out the 2' encroachment agreement
SWALE COMPLETE 06/06/2022 08/30/2022
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
PLAN REVIEW - REVISION ¤32.50 05/02/2025
PLAN REVIEW - REVISION ¤32.50 05/02/2025
REINSPECTION RESIDENTIAL ¤40.00 05/02/2025
REINSPECTION RESIDENTIAL ¤40.00 05/02/2025
REINSPECTION RESIDENTIAL ¤40.00 05/02/2025
REINSPECTION RESIDENTIAL ¤40.00 05/02/2025
REINSPECTION RESIDENTIAL ¤40.00 05/02/2025
REINSPECTION RESIDENTIAL ¤40.00 05/02/2025
REINSPECTION RESIDENTIAL ¤40.00 05/02/2025
REINSPECTION RESIDENTIAL ¤40.00 05/02/2025
REINSPECTION RESIDENTIAL ¤40.00 05/02/2025
REINSPECTION RESIDENTIAL ¤40.00 05/02/2025
REINSPECTION RESIDENTIAL ¤40.00 05/02/2025
CONTRACTOR CHANGE ¤20.00 05/02/2025
CONTRACTOR CHANGE ¤20.00 05/02/2025
CONTRACTOR CHANGE ¤100.00 05/02/2025
CONTRACTOR CHANGE ¤20.00 05/02/2025
REINSPECTION FEE ¤40.00 05/02/2025
SURCHARGE FS 533.721 ¤4.14 11/03/2022
SURCHARGE - FS 468.631 ¤6.21 11/03/2022
SW ENG - FOUNDATION SURVEY ¤20.00 11/03/2022
SW ENG INSPECTION 80 ¤80.00 11/03/2022
SW ENG PRE APRON ¤30.00 11/03/2022
SW ENG - REVIEW 20 ¤20.00 11/03/2022
SW ENG RES REVIEW 200 ¤200.00 11/03/2022
3% TRANS IMPACT FEE CREDIT (¤52.92) 11/03/2022
SEWER INSPECTION ¤25.00 11/03/2022
SEWER CAPITAL FACILITY ¤4,939.76 11/03/2022
WATER CREDIT (¤1,146.32) 11/03/2022
WATER CAPITAL FACILITY FEE ¤3,626.50 11/03/2022
SITE PLAN 30 ¤30.00 11/03/2022
WATER- TURN ON ¤25.00 11/03/2022
ADJUSTMENT 50% (¤657.46) 11/03/2022
ADMINISTRATIVE RESIDENTIAL ¤30.00 11/03/2022
INSPECTION - RESIDENTIAL ¤1,001.00 11/03/2022
PLAN REVIEW - RESIDENTIAL ¤283.92 11/03/2022
3% FIRE IMPACT FEE CREDIT (¤11.66) 11/03/2022
IMPACT FEE FIRE ¤388.65 11/03/2022
IMPACT FEE PARKS ¤1,455.13 11/03/2022
IMPACT FEE SCHOOL ¤3,600.00 11/03/2022
IMPACT FEE TRANSPORTATION ¤1,764.00 11/03/2022
WATER -IRRIGATION INSPECTION ¤25.00 11/03/2022
3% PARKS IMPACT FEE CREDIT (¤43.65) 11/03/2022
CONNECTION FEES ¤1,077.88 11/03/2022
Fees Total Due: ¤0.00 Total Paid: ¤17,425.18