I want to search for...
Permit #2022060339
Permit Details
Status: COED
| Parcel Id: 07-11-31-7023-00210-0110 |
| CONDITIONED SPACE: 2170 sqft |
| OPENED PORCH (WITH ROOF) : 114 sqft |
| OPENED PORCH (WITH ROOF) : 497 sqft |
| GARAGE: 473 sqft |
| Total Square Footage: 3254 sqft |
| Block: 00210 |
| Subdivision: 2191 - SECTION 23-WYNNFIELD |
| Job Phone: 386-237-5837 |
| Location Address: 62 WHITTINGTON DR |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 11/03/2022 |
| NOC: RECORDED |
| Applicant name: MARSEL GILMANSHIN |
| Owner: LEONOVA LARISA |
|
Address 6 COCHRAN LANE PALM COAST, FL 32137 |
| Lot: 0110 |
| Contracted Stated Job Value: ¤364,000.00 |
| Job Description: Single Family Residence |
| Type: CN |
Contractor
GILMANS DEVELOPMENT CORP
| Status | Location Address | State License Number | Phone |
| ACTIVE |
4873 PALM COAST PARKWAY NW #4 PALM COAST, FL 32137 |
CBC1263180 (Exp: 08/31/2026) | 386-237-5837 |
Sub Contractors
FERNANDO MEZA SR
| Status | Location Address | State License Number | Phone |
| ACTIVE |
457 CHELSEA PLACE AVE ORMOND BEACH, FL 32174 |
EC13003906 (Exp: 08/31/2026) | 386-241-5211 |
ALEKSANDR A KATKO
| Status | Location Address | State License Number | Phone |
| ACTIVE |
130 HARRISON RD , 0 |
CFC1431723 (Exp: 08/31/2026) | 386-341-3800 |
JUAN CARLOS GONZALEZ
| Status | Location Address | State License Number |
| ACTIVE |
1328 COUNTY ROAD 308 CRESCENT CITY, FL 32112 |
RF11067806 (Exp: 08/31/2027) |
MARSEL GILMANSHIN
| Status | Location Address | State License Number | Phone |
| ACTIVE |
4873 PALM COAST PARKWAY NW #4 PALM COAST, FL 32137 |
CBC1263180 (Exp: 08/31/2026) | 386-237-5837 |
RUSLAN KHUSNIYAROV
| Status | Location Address | State License Number |
| INACTIVE |
74 EDWARD DR PALM COAST, FL 32164 |
CAC1822489 (Exp: 08/31/2026) |
Inspection History
| Type | Request Date | Result | Inspector |
| BLD - BUILDING FINAL | 05/02/2025 | FINAL APPROVED | MCONTRYMAN |
| Note: 5/1/2025 - PREVIOUS INSPECTION NOTES 5/1/25 1. E-cals have not been approved by Building Department FBC (A)107.4 2. Sch 40 caps required on back lani for future plumbing 3. Can lights must be fire rated in garage FBC R302.6 4. AHU breaker oversized FBCR M1303.1 4/28/2025 - PREVIOUS INSPECTION NOTES 1. E-cals dont match the equipment that was installed FBC (A)107.4 2. Water heater requires a shut off 3. AHU heater sticker not marked to check proper breaker size FBCR M1303.1 4. Kitchen sink is missing p-trap 5. Kitchen sink missing auto vent 6. Dishwasher missing water hammer arrester FBCR P2903.5 7. Future plumbing lines out side require a sch 40 cap (drain) 8. ODU requires 4 tie downs FBC M1401.1 9. All sink must be hard piped flex pipe is not approved per manufacturer spec 10. Can lights in garage must be fire rated FBC R302.6 11. ODU plastic box for power must have an approved seal for unuesd opening NEC 110.12 12. Dishwasher drain line is required to be supported up FBCR P2717.2 | |||
| BLD - BUILDING FINAL | 05/01/2025 | Disapproved -FEE REQUIRED | MKRASKI |
| Note: 5/1/25 1. E-cals have not been approved by Building Department FBC (A)107.4 2. Sch 40 caps required on back lani for future plumbing 3. Can lights must be fire rated in garage FBC R302.6 4. AHU breaker oversized FBCR M1303.1 4/28/2025 - PREVIOUS INSPECTION NOTES 1. E-cals dont match the equipment that was installed FBC (A)107.4 2. Water heater requires a shut off 3. AHU heater sticker not marked to check proper breaker size FBCR M1303.1 4. Kitchen sink is missing p-trap 5. Kitchen sink missing auto vent 6. Dishwasher missing water hammer arrester FBCR P2903.5 7. Future plumbing lines out side require a sch 40 cap (drain) 8. ODU requires 4 tie downs FBC M1401.1 9. All sink must be hard piped flex pipe is not approved per manufacturer spec 10. Can lights in garage must be fire rated FBC R302.6 11. ODU plastic box for power must have an approved seal for unuesd opening NEC 110.12 12. Dishwasher drain line is required to be supported up FBCR P2717.2 | |||
| BLD - BUILDING FINAL | 04/28/2025 | Disapproved - NO FEE | MKRASKI |
| Note: 1. E-cals dont match the equipment that was installed FBC (A)107.4 2. Water heater requires a shut off 3. AHU heater sticker not marked to check proper breaker size FBCR M1303.1 4. Kitchen sink is missing p-trap 5. Kitchen sink missing auto vent 6. Dishwasher missing water hammer arrester FBCR P2903.5 7. Future plumbing lines out side require a sch 40 cap (drain) 8. ODU requires 4 tie downs FBC M1401.1 9. All sink must be hard piped flex pipe is not approved per manufacturer spec 10. Can lights in garage must be fire rated FBC R302.6 11. ODU plastic box for power must have an approved seal for unuesd opening NEC 110.12 12. Dishwasher drain line is required to be supported up FBCR P2717.2 | |||
| BLD - BUILDING FINAL | 04/24/2025 | Disapproved -FEE REQUIRED | CVANSTRAHLEN |
| Note: Please fix items before next inspection #1-E-cals do not match equitment install for AC and AH , please provide new e-Cals documents #2- light and exahusted switch for master bathroom can't no be behind the bathroom door #3- fire place in leaving room need a dedicateed circuit. (need a 15 amp breaker ) fire place factory amp is 12.5 #4-FBC [A] 105.7 -NEEDS PERMIT ON SITE #5-FBC-R . 302.6 seal all garage penetration , wall and ceiling ( low voltage wire AHU Plenum conduit )wall behind AH box missing drywall #6-1. ODU needs to be 3" from finished grade FBCR M1305.1.4.1 | |||
| ROW - FINAL APRON (AFTER POUR) | 04/21/2025 | APPROVED | TPOLACEK |
| Note: PIPE ELEVATION IS GOOD, CUTS ARE MADE, CULVERT CLEAR, HOT PATCH COMPLETE, AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED | |||
| ROW - STORMWATER FINAL | 04/21/2025 | APPROVED | TPOLACEK |
| Note: AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED | |||
| U -UTILITY RESIDENTIAL FINAL | 04/21/2025 | APPROVED - AS NOTED | LFITZGERALD |
| Note: lower sewe C/O riser PIPE-attach proper cap-send pic when done | |||
| ROW FIELD SURVEY /GRADING CERTIFICATION | 04/17/2025 | APPROVED | TPOLACEK |
| Note: CORRECTIONS MADE. AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED 4/15/2025 - PREVIOUS INSPECTION NOTES 04/15/25 TPOLACEK*** SPOKE WITH CM ON PHONE AND EXPLAIND BOTH SIDE PROPERTY LINES NEEDS HIGHER BERM TO STOP DRAINAGE FROM NEGATIVLEY IMPACTING ADJOINING PROPERTIES. Top of the slope Sec 300.02.C(6) Sec 300.02.C(6)=The top of slope of “W” swales along the property lines shall be a minimum of 0.30 of a foot higher than the toe of slope. | |||
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 04/15/2025 | APPROVED | TPOLACEK |
| ROW FIELD SURVEY /GRADING CERTIFICATION | 04/15/2025 | Disapproved - NO FEE | TPOLACEK |
| Note: 04/15/25 TPOLACEK*** SPOKE WITH CM ON PHONE AND EXPLAIND BOTH SIDE PROPERTY LINES NEEDS HIGHER BERM TO STOP DRAINAGE FROM NEGATIVLEY IMPACTING ADJOINING PROPERTIES. Top of the slope Sec 300.02.C(6) Sec 300.02.C(6)=The top of slope of “W” swales along the property lines shall be a minimum of 0.30 of a foot higher than the toe of slope. | |||
| ELECTRIC - EARLY POWER | 04/07/2025 | APPROVED - AS NOTED | MKRASKI |
| Note: Emailed FPL @ 2:40pm | |||
| ROW- PRE-APRON (PRE-POUR) | 03/24/2025 | APPROVED | TPOLACEK |
| Note: AT THE TIME OF THE INSPECTION CULVERT PIPE IS GOOD IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD DOUBLE CHECK CULVERT ELEVATIONS MAKE SURE TO USE 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. CONTRACTORS WILL BE NOTIFIED WHEN TICKETS WILL BE REQUIRED WITH AN EMAIL BLAST.THE FOLLOWING IS CURRENTLY FOR INFORMATION ONLY: TICKET OF CONCRETE MIX DESIGN SHALL BE UPLOADED INTO PERMIT PORTAL. 8.a. IF FIBERGLASS OPTION IS USED, DOCUMENTATION OF THE ( FRC) CONTAINING THE FIBERGLASS MUST BE ATTACHED TO THE PERMIT PRIOR TO REQUESTING AN AFTER-POUR INSPECTION. 8.b. IF MESH OPTION IS USED, IT SHALL BE IN PLACE AT THE TIME OF THE PRE-POUR. | |||
| U - SEWER TIE IN | 02/20/2025 | APPROVED - AS NOTED | MGIBSON |
| Note: THIS WAS ADDED BY INSPECTOR | |||
| GRAVITY SEWER TEST | 02/20/2025 | APPROVED - AS NOTED | MGIBSON |
| Note: U-SEWER TIE IN IS ALSO APPROVED | |||
| INSULATION | 02/03/2025 | APPROVED | MKRASKI |
| Note: | |||
| PEP TANK INSTALLATION REQUEST | 02/03/2025 | APPROVED | CBOWERMASTER |
| LATH/BRICK/ WATER BARRIER | 01/22/2025 | APPROVED - AS NOTED | MKRASKI |
| Note: 1. No dumpster on site FBC 3302.2 2. Silt fence must be kept in orginal condition FBC 3307.1 | |||
| INSULATION | 01/13/2025 | CANCELLED BY APPLICANT | MKRASKI |
| Note: Inspector Notes from Inspection 2420 1/6/25 1. Failed 5' head pressure test 2. Mech duct work does not match duck work layout on E-cals 3. Revision required for MI windows installed 4. Seal elec chase @ island Make ALL repairs before calling in insulation 12/31/2024 - PREVIOUS INSPECTION NOTES 12/31/24 1. Previous items not repaired FBC [A] 110.6 2. Windows do not match product approval sheet FBC [A]107.4 3. Address not visible form street FBC 319.1 4. Front door required solid blocking gaps exceeding 1/4'' max FBCR 609.1 5. E-cals duct layout do not match what is installed FBC [A]107.4 6. Exterior swing doors not installed to check anchors and gaps FBCR 609.1 7. Failed 5' head pressure FBCR P2503.7 8. Crushed supply ducts FBC M1301.3 9. Elec chase needs to be sealed at slab FBC R402.4.1.1 10. Exhaust fans require 2 points of attachment FBCR M1604.4.1 11. All a/c registers require seal FBC R402.4.1.1 ***Make ALL repairs before calling in for re-inspection*** 12/19/2024 - PREVIOUS INSPECTION NOTES 1. Stickers have been removed from most windows 2. Product approval sheet does not match windows installed 3. No plans on site or E-cals FBC 107.3.1 4. No 50 lbs of pressure on supply lines FBCR P2503.5 5. Failed 5' head pressure test and tubs not filled to over flow FBCR P2503.7 6. Exhaust fan duct attachment requires two points of attachment FBCR M1604.4.1 7. All a/c registers require seal FBC R402.4.1.1 *** Insulation was already installed, Do not insulate untill after all rough has been approved per Building Dept. *** | |||
| ALL ROUGH | 01/06/2025 | APPROVED - AS NOTED | MKRASKI |
| Note: 1/6/25 1. Failed 5' head pressure test 2. Mech duct work does not match duck work layout on E-cals 3. Revision required for MI windows installed 4. Seal elec chase @ island Make ALL repairs before calling in insulation 12/31/2024 - PREVIOUS INSPECTION NOTES 12/31/24 1. Previous items not repaired FBC [A] 110.6 2. Windows do not match product approval sheet FBC [A]107.4 3. Address not visible form street FBC 319.1 4. Front door required solid blocking gaps exceeding 1/4'' max FBCR 609.1 5. E-cals duct layout do not match what is installed FBC [A]107.4 6. Exterior swing doors not installed to check anchors and gaps FBCR 609.1 7. Failed 5' head pressure FBCR P2503.7 8. Crushed supply ducts FBC M1301.3 9. Elec chase needs to be sealed at slab FBC R402.4.1.1 10. Exhaust fans require 2 points of attachment FBCR M1604.4.1 11. All a/c registers require seal FBC R402.4.1.1 ***Make ALL repairs before calling in for re-inspection*** 12/19/2024 - PREVIOUS INSPECTION NOTES 1. Stickers have been removed from most windows 2. Product approval sheet does not match windows installed 3. No plans on site or E-cals FBC 107.3.1 4. No 50 lbs of pressure on supply lines FBCR P2503.5 5. Failed 5' head pressure test and tubs not filled to over flow FBCR P2503.7 6. Exhaust fan duct attachment requires two points of attachment FBCR M1604.4.1 7. All a/c registers require seal FBC R402.4.1.1 *** Insulation was already installed, Do not insulate untill after all rough has been approved per Building Dept. *** | |||
| ALL ROUGH | 12/31/2024 | Disapproved -FEE REQUIRED | MKRASKI |
| Note: 12/31/24 1. Previous items not repaired FBC [A] 110.6 2. Windows do not match product approval sheet FBC [A]107.4 3. Address not visible form street FBC 319.1 4. Front door required solid blocking gaps exceeding 1/4'' max FBCR 609.1 5. E-cals duct layout do not match what is installed FBC [A]107.4 6. Exterior swing doors not installed to check anchors and gaps FBCR 609.1 7. Failed 5' head pressure FBCR P2503.7 8. Crushed supply ducts FBC M1301.3 9. Elec chase needs to be sealed at slab FBC R402.4.1.1 10. Exhaust fans require 2 points of attachment FBCR M1604.4.1 11. All a/c registers require seal FBC R402.4.1.1 ***Make ALL repairs before calling in for re-inspection*** 12/19/2024 - PREVIOUS INSPECTION NOTES 1. Stickers have been removed from most windows 2. Product approval sheet does not match windows installed 3. No plans on site or E-cals FBC 107.3.1 4. No 50 lbs of pressure on supply lines FBCR P2503.5 5. Failed 5' head pressure test and tubs not filled to over flow FBCR P2503.7 6. Exhaust fan duct attachment requires two points of attachment FBCR M1604.4.1 7. All a/c registers require seal FBC R402.4.1.1 *** Insulation was already installed, Do not insulate untill after all rough has been approved per Building Dept. *** | |||
| ALL ROUGH | 12/19/2024 | Disapproved -FEE REQUIRED | MKRASKI |
| Note: 1. Stickers have been removed from most windows 2. Product approval sheet does not match windows installed 3. No plans on site or E-cals FBC 107.3.1 4. No 50 lbs of pressure on supply lines FBCR P2503.5 5. Failed 5' head pressure test and tubs not filled to over flow FBCR P2503.7 6. Exhaust fan duct attachment requires two points of attachment FBCR M1604.4.1 7. All a/c registers require seal FBC R402.4.1.1 *** Insulation was already installed, Do not insulate untill after all rough has been approved per Building Dept. *** ***Full re-inspection required*** | |||
| WALL SHEATHING | 11/22/2024 | APPROVED | MKRASKI |
| LATH/BRICK/ WATER BARRIER | 11/22/2024 | Disapproved -FEE REQUIRED | MKRASKI |
| Note: 1. No porta jon on site FBC P311.1 2. No dumpster on site FBC 3302.2 3. Silt fence must be kept in orginal condition FBC 3307.1 4. All exterior penitrations and holes in block require water barrier and lath R402.4.1.1 | |||
| ROOF VALLEY & METAL | 06/27/2024 | APPROVED | FWILLIS |
| Note: Inspector Notes from Inspection 2460 6/17/24 1. CMU to load bearing wall not per detail 2. Load bearing wall not per detail missing blocking and SPs on every stud 3. Need Load bearing door opening deatil Check on next inspection 5/24/2024 - PREVIOUS INSPECTION NOTES 5/24/24 Make ALL previous notes repaired before calling in re-inspection, Look at detais for load bearing walls and load bearing to CMU attachment, NOT READY 5/22/2024 - PREVIOUS INSPECTION NOTES 05-22-2024 1. EJ02P at lanai missing truss plate. 2. T20 truss at lanai not fastened properly. 3. T01 strap not fastened properly. 4. Sheet 5 Isometric connection frame to CMU not installed as per plan. Check all areas. 5. Load bearing wall detail not on site. 6. Engineering and truss layout do not match. Framer on site. Contractor not ready. A complete inspection will be required for next inspection. DOCUMENTS MUST BE APPROVED AND KEPT ON SITE 107.3,1. AND SHALL BE OPEN TO INSPECTION BY THE BUILDING OFFICIAL 5/6/2024 - PREVIOUS INSPECTION NOTES 5/6/24 Please review all previous notes and make repairs before calling im re-inspection . 4/3/2024 - PREVIOUS INSPECTION NOTES 4/3/24 Make all previous repairs before calling in re-in spection, truss straps missing, Load bearing wall to CMU not per detail per new revison stopped inspection 3/21/2024 - PREVIOUS INSPECTION NOTES 3/19/24 1. Still no interior load bearing wall detail, detail needs to be submitted and approved by Building Dept. before calling in re-inspection 2. No Load bearing wall attachment to CMU detail, also needs a revision 3. Multiple truss straps still missing Stopped inspection make all repairs before calling in re-inspection Did not check engineering 3/8/2024 - PREVIOUS INSPECTION NOTES 3/8/24 All previous items must be repaired before calling in re-inspection 3/5/2024 - PREVIOUS INSPECTION NOTES 3/5/24 1. Multiple trusses missing straps check all 2. No interior load bearing wall detail 3. No truss enginnering on site 4. Job box needs to be installed in yard facing road with address 5. No dumpster on site, some trash still needs to be cleaned up Stopped inspection, not ready 2/29/2024 - PREVIOUS INSPECTION NOTES From previous inspection, Silt fence has not been installed, stopped inspection. Call in for re-inspection after repair has been made/ Clean up trash also | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 06/17/2024 | APPROVED - AS NOTED | MKRASKI |
| Note: 6/17/24 1. CMU to load bearing wall not per detail 2. Load bearing wall not per detail missing blocking and SPs on every stud 3. Need Load bearing door opening deatil Check on next inspection 5/24/2024 - PREVIOUS INSPECTION NOTES 5/24/24 Make ALL previous notes repaired before calling in re-inspection, Look at detais for load bearing walls and load bearing to CMU attachment, NOT READY 5/22/2024 - PREVIOUS INSPECTION NOTES 05-22-2024 1. EJ02P at lanai missing truss plate. 2. T20 truss at lanai not fastened properly. 3. T01 strap not fastened properly. 4. Sheet 5 Isometric connection frame to CMU not installed as per plan. Check all areas. 5. Load bearing wall detail not on site. 6. Engineering and truss layout do not match. Framer on site. Contractor not ready. A complete inspection will be required for next inspection. DOCUMENTS MUST BE APPROVED AND KEPT ON SITE 107.3,1. AND SHALL BE OPEN TO INSPECTION BY THE BUILDING OFFICIAL 5/6/2024 - PREVIOUS INSPECTION NOTES 5/6/24 Please review all previous notes and make repairs before calling im re-inspection . 4/3/2024 - PREVIOUS INSPECTION NOTES 4/3/24 Make all previous repairs before calling in re-in spection, truss straps missing, Load bearing wall to CMU not per detail per new revison stopped inspection 3/21/2024 - PREVIOUS INSPECTION NOTES 3/19/24 1. Still no interior load bearing wall detail, detail needs to be submitted and approved by Building Dept. before calling in re-inspection 2. No Load bearing wall attachment to CMU detail, also needs a revision 3. Multiple truss straps still missing Stopped inspection make all repairs before calling in re-inspection Did not check engineering 3/8/2024 - PREVIOUS INSPECTION NOTES 3/8/24 All previous items must be repaired before calling in re-inspection 3/5/2024 - PREVIOUS INSPECTION NOTES 3/5/24 1. Multiple trusses missing straps check all 2. No interior load bearing wall detail 3. No truss enginnering on site 4. Job box needs to be installed in yard facing road with address 5. No dumpster on site, some trash still needs to be cleaned up Stopped inspection, not ready 2/29/2024 - PREVIOUS INSPECTION NOTES From previous inspection, Silt fence has not been installed, stopped inspection. Call in for re-inspection after repair has been made/ Clean up trash also | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 05/24/2024 | Disapproved -FEE REQUIRED | MKRASKI |
| Note: 5/24/24 Make ALL previous notes repaired before calling in re-inspection, Look at detais for load bearing walls and load bearing to CMU attachment, NOT READY 5/22/2024 - PREVIOUS INSPECTION NOTES 05-22-2024 1. EJ02P at lanai missing truss plate. 2. T20 truss at lanai not fastened properly. 3. T01 strap not fastened properly. 4. Sheet 5 Isometric connection frame to CMU not installed as per plan. Check all areas. 5. Load bearing wall detail not on site. 6. Engineering and truss layout do not match. Framer on site. Contractor not ready. A complete inspection will be required for next inspection. DOCUMENTS MUST BE APPROVED AND KEPT ON SITE 107.3,1. AND SHALL BE OPEN TO INSPECTION BY THE BUILDING OFFICIAL 5/6/2024 - PREVIOUS INSPECTION NOTES 5/6/24 Please review all previous notes and make repairs before calling im re-inspection . 4/3/2024 - PREVIOUS INSPECTION NOTES 4/3/24 Make all previous repairs before calling in re-in spection, truss straps missing, Load bearing wall to CMU not per detail per new revison stopped inspection 3/21/2024 - PREVIOUS INSPECTION NOTES 3/19/24 1. Still no interior load bearing wall detail, detail needs to be submitted and approved by Building Dept. before calling in re-inspection 2. No Load bearing wall attachment to CMU detail, also needs a revision 3. Multiple truss straps still missing Stopped inspection make all repairs before calling in re-inspection Did not check engineering 3/8/2024 - PREVIOUS INSPECTION NOTES 3/8/24 All previous items must be repaired before calling in re-inspection 3/5/2024 - PREVIOUS INSPECTION NOTES 3/5/24 1. Multiple trusses missing straps check all 2. No interior load bearing wall detail 3. No truss enginnering on site 4. Job box needs to be installed in yard facing road with address 5. No dumpster on site, some trash still needs to be cleaned up Stopped inspection, not ready 2/29/2024 - PREVIOUS INSPECTION NOTES From previous inspection, Silt fence has not been installed, stopped inspection. Call in for re-inspection after repair has been made/ Clean up trash also | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 05/22/2024 | Disapproved - NO FEE | AGAETANO |
| Note: 05-22-2024 1. EJ02P at lanai missing truss plate. 2. T20 truss at lanai not fastened properly. 3. T01 strap not fastened properly. 4. Sheet 5 Isometric connection frame to CMU not installed as per plan. Check all areas. 5. Load bearing wall detail not on site. 6. Engineering and truss layout do not match. Framer on site. Contractor not ready. A complete inspection will be required for next inspection. DOCUMENTS MUST BE APPROVED AND KEPT ON SITE 107.3,1. AND SHALL BE OPEN TO INSPECTION BY THE BUILDING OFFICIAL 5/6/2024 - PREVIOUS INSPECTION NOTES 5/6/24 Please review all previous notes and make repairs before calling im re-inspection . 4/3/2024 - PREVIOUS INSPECTION NOTES 4/3/24 Make all previous repairs before calling in re-in spection, truss straps missing, Load bearing wall to CMU not per detail per new revison stopped inspection 3/21/2024 - PREVIOUS INSPECTION NOTES 3/19/24 1. Still no interior load bearing wall detail, detail needs to be submitted and approved by Building Dept. before calling in re-inspection 2. No Load bearing wall attachment to CMU detail, also needs a revision 3. Multiple truss straps still missing Stopped inspection make all repairs before calling in re-inspection Did not check engineering 3/8/2024 - PREVIOUS INSPECTION NOTES 3/8/24 All previous items must be repaired before calling in re-inspection 3/5/2024 - PREVIOUS INSPECTION NOTES 3/5/24 1. Multiple trusses missing straps check all 2. No interior load bearing wall detail 3. No truss enginnering on site 4. Job box needs to be installed in yard facing road with address 5. No dumpster on site, some trash still needs to be cleaned up Stopped inspection, not ready 2/29/2024 - PREVIOUS INSPECTION NOTES From previous inspection, Silt fence has not been installed, stopped inspection. Call in for re-inspection after repair has been made/ Clean up trash also | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 05/06/2024 | Disapproved -FEE REQUIRED | MKRASKI |
| Note: 5/6/24 Please review all previous notes and make repairs before calling im re-inspection . 4/3/2024 - PREVIOUS INSPECTION NOTES 4/3/24 Make all previous repairs before calling in re-in spection, truss straps missing, Load bearing wall to CMU not per detail per new revison stopped inspection 3/21/2024 - PREVIOUS INSPECTION NOTES 3/19/24 1. Still no interior load bearing wall detail, detail needs to be submitted and approved by Building Dept. before calling in re-inspection 2. No Load bearing wall attachment to CMU detail, also needs a revision 3. Multiple truss straps still missing Stopped inspection make all repairs before calling in re-inspection Did not check engineering 3/8/2024 - PREVIOUS INSPECTION NOTES 3/8/24 All previous items must be repaired before calling in re-inspection 3/5/2024 - PREVIOUS INSPECTION NOTES 3/5/24 1. Multiple trusses missing straps check all 2. No interior load bearing wall detail 3. No truss enginnering on site 4. Job box needs to be installed in yard facing road with address 5. No dumpster on site, some trash still needs to be cleaned up Stopped inspection, not ready 2/29/2024 - PREVIOUS INSPECTION NOTES From previous inspection, Silt fence has not been installed, stopped inspection. Call in for re-inspection after repair has been made/ Clean up trash also | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 04/03/2024 | Disapproved -FEE REQUIRED | MKRASKI |
| Note: 4/3/24 Make all previous repairs before calling in re-in spection, truss straps missing, Load bearing wall to CMU not per detail per new revison stopped inspection 3/21/2024 - PREVIOUS INSPECTION NOTES 3/19/24 1. Still no interior load bearing wall detail, detail needs to be submitted and approved by Building Dept. before calling in re-inspection 2. No Load bearing wall attachment to CMU detail, also needs a revision 3. Multiple truss straps still missing Stopped inspection make all repairs before calling in re-inspection Did not check engineering 3/8/2024 - PREVIOUS INSPECTION NOTES 3/8/24 All previous items must be repaired before calling in re-inspection 3/5/2024 - PREVIOUS INSPECTION NOTES 3/5/24 1. Multiple trusses missing straps check all 2. No interior load bearing wall detail 3. No truss enginnering on site 4. Job box needs to be installed in yard facing road with address 5. No dumpster on site, some trash still needs to be cleaned up Stopped inspection, not ready 2/29/2024 - PREVIOUS INSPECTION NOTES From previous inspection, Silt fence has not been installed, stopped inspection. Call in for re-inspection after repair has been made/ Clean up trash also | |||
| ROOF VALLEY & METAL | 03/26/2024 | CANCELLED BY APPLICANT | WEB |
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 03/21/2024 | Disapproved -FEE REQUIRED | MKRASKI |
| Note: 3/19/24 1. Still no interior load bearing wall detail, detail needs to be submitted and approved by Building Dept. before calling in re-inspection 2. No Load bearing wall attachment to CMU detail, also needs a revision 3. Multiple truss straps still missing Stopped inspection make all repairs before calling in re-inspection Did not check engineering 3/8/2024 - PREVIOUS INSPECTION NOTES 3/8/24 All previous items must be repaired before calling in re-inspection 3/5/2024 - PREVIOUS INSPECTION NOTES 3/5/24 1. Multiple trusses missing straps check all 2. No interior load bearing wall detail 3. No truss enginnering on site 4. Job box needs to be installed in yard facing road with address 5. No dumpster on site, some trash still needs to be cleaned up Stopped inspection, not ready 2/29/2024 - PREVIOUS INSPECTION NOTES From previous inspection, Silt fence has not been installed, stopped inspection. Call in for re-inspection after repair has been made/ Clean up trash also | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 03/08/2024 | Disapproved -FEE REQUIRED | MKRASKI |
| Note: 3/8/24 All previous items must be repaired before calling in re-inspection 3/5/2024 - PREVIOUS INSPECTION NOTES 3/5/24 1. Multiple trusses missing straps check all 2. No interior load bearing wall detail 3. No truss enginnering on site 4. Job box needs to be installed in yard facing road with address 5. No dumpster on site, some trash still needs to be cleaned up Stopped inspection, not ready 2/29/2024 - PREVIOUS INSPECTION NOTES From previous inspection, Silt fence has not been installed, stopped inspection. Call in for re-inspection after repair has been made/ Clean up trash also | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 03/05/2024 | Disapproved -FEE REQUIRED | MKRASKI |
| Note: 3/5/24 1. Multiple trusses missing straps check all 2. No interior load bearing wall detail 3. No truss enginnering on site 4. Job box needs to be installed in yard facing road with address 5. No dumpster on site, some trash still needs to be cleaned up Stopped inspection, not ready 2/29/2024 - PREVIOUS INSPECTION NOTES From previous inspection, Silt fence has not been installed, stopped inspection. Call in for re-inspection after repair has been made/ Clean up trash also | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 02/29/2024 | Disapproved -FEE REQUIRED | MKRASKI |
| Note: From previous inspection, Silt fence has not been installed, stopped inspection. Call in for re-inspection after repair has been made/ Clean up trash also | |||
| ELECTRIC TEMP POLE | 01/08/2024 | APPROVED | RMARTIN |
| ELECTRIC TEMP POLE | 01/08/2024 | APPROVED - AS NOTED | RMARTIN |
| Note: NEED TO INSTALL SILT FENCE BY NEXT INSPECTION | |||
| MONOLITHIC SLAB | 04/10/2023 | APPROVED | MKRASKI |
| TIE BEAM / LINTEL | 03/15/2023 | APPROVED | MKRASKI |
| FOUND SURVEY APPROVED (OFFICE) | 02/22/2023 | APPROVED | TBAKER |
| MONOLITHIC SLAB | 02/01/2023 | APPROVED | MKRASKI |
| PLUMBING 1ST ROUGH UNDERGROUND | 01/31/2023 | APPROVED | MGIBSON |
| Note: 1/27/2023 - PREVIOUS INSPECTION NOTES 1/24/2023 - PREVIOUS INSPECTION NOTES NOT HOLDING 5' HEAD TEST 5' HEAD TEST STILL NOT HOLDING | |||
| PLUMBING 1ST ROUGH UNDERGROUND | 01/27/2023 | Disapproved - NO FEE | MGIBSON |
| Note: 1/24/2023 - PREVIOUS INSPECTION NOTES NOT HOLDING 5' HEAD TEST 5' HEAD TEST STILL NOT HOLDING | |||
| PLUMBING 1ST ROUGH UNDERGROUND | 01/24/2023 | Disapproved -FEE REQUIRED | MGIBSON |
| Note: NOT HOLDING 5' HEAD TEST AND NEED TO LIST CORRECT PLUMBING CONTRACTOR | |||
| WATER METER INSTALLATION REQUEST | 12/16/2022 | APPROVED | CSTONE |
| Note: 11/22/2022 8:20:15 AM- PREVIOUS INSPECTION NOTES 11/17/2022 8:47:43 AM- PREVIOUS INSPECTION NOTES still clearing still clearing 11/21 | |||
| WATER METER INSTALLATION REQUEST | 11/21/2022 | Disapproved -FEE REQUIRED | CSTONE |
| Note: 11/17/2022 8:47:43 AM- PREVIOUS INSPECTION NOTES still clearing still clearing 11/21 | |||
| WATER METER INSTALLATION REQUEST | 11/15/2022 | Disapproved - NO FEE | CSTONE |
| Note: still clearing |
Review History
| Department | Status | Date In | Date Out |
| MECH | COMPLETE | 05/01/2025 | 05/01/2025 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 01/23/2025 | 01/29/2025 |
| Note: Released By: PETER KNAPIK - (386)986-3783 - PKNAPIK@PALMCOASTGOV.COM | |||
| BLD | HOLD | 01/13/2025 | 01/17/2025 |
| Note: Held By: PETER KNAPIK - - PKNAPIK@PALMCOASTGOV.COM 1. FL# 18644 and FL# 41866, neither are Single/Double hung windows. Please revise. | |||
| MECH | COMPLETE | 08/20/2024 | 08/21/2024 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| MECH | HOLD | 08/14/2024 | 08/19/2024 |
| Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM 1. Provide duct layout signed by the AC Contractor (Page is blank. Need duct layout) second request | |||
| MECH | HOLD | 08/06/2024 | 08/12/2024 |
| Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM 1. Provide duct layout signed by the AC Contractor 2. List mechanical subcontractor on portal | |||
| BLD | COMPLETE | 07/30/2024 | 08/01/2024 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 05/14/2024 | 05/20/2024 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM KS | |||
| BLD | COMPLETE | 03/26/2024 | 04/01/2024 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 02/21/2023 | 02/22/2023 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 02/21/2023 | 02/22/2023 |
| Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM | |||
| ENGIN1 | HOLD | 02/15/2023 | 02/15/2023 |
| Note: Held By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM Elevation of slab on foundation survey is 1.5' +/- higher than approved site plan. Please revise appropriate drawing and resubmit. | |||
| ZON | COMPLETE | 02/15/2023 | 02/15/2023 |
| Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 02/14/2023 | 02/15/2023 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 02/14/2023 | 02/14/2023 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 02/14/2023 | 02/14/2023 |
| Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 01/11/2023 | 01/12/2023 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| SW1 | COMPLETE | 01/11/2023 | 01/19/2023 |
| Note: Released By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 01/11/2023 | 01/11/2023 |
| Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 07/07/2022 | 07/07/2022 |
| Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM | |||
| ZON | HOLD | 06/28/2022 | 06/28/2022 |
| Note: Held By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM add a/c to floor plan and landscap plan they continue to not mach | |||
| ENGIN1 | COMPLETE | 06/27/2022 | 06/28/2022 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| SW1 | COMPLETE | 06/27/2022 | 07/07/2022 |
| Note: Released By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM | |||
| ZON | HOLD | 06/21/2022 | 06/21/2022 |
| Note: Held By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM Repeat Comment: On site plan submitted the A/C pad is missing. Please include that in your plans If your mechanical equipment is encroaching then you will need to fill out the 2' encroachment agreement | |||
| ELEC | COMPLETE | 06/21/2022 | 06/21/2022 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| ELEC | COMPLETE | 06/09/2022 | 06/09/2022 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 06/06/2022 | 06/09/2022 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| CUSVC | COMPLETE | 06/06/2022 | 06/07/2022 |
| Note: Released By: CYNTHIA SCHWEERS - - CSCHWEERS@PALMCOASSTGOV.COM | |||
| ELEC | HOLD | 06/06/2022 | 06/07/2022 |
| Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM Submit electric load calcs | |||
| ENGIN1 | COMPLETE | 06/06/2022 | 06/06/2022 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| LOCATE | COMPLETE | 06/06/2022 | 06/13/2022 |
| Note: Released By: CANDACE STONE - - CSTONE@PALMCOASTGOV.COM | |||
| MECH | COMPLETE | 06/06/2022 | 06/07/2022 |
| Note: Released By: CHRIS PISCITELLI - (386)986-3782 - CPISCITELLI@PALMCOASTGOV.COM | |||
| SW1 | COMPLETE | 06/06/2022 | 06/13/2022 |
| Note: Released By: EDWARD MADISON - - EMADISON@PALMCOASTGOV.COM | |||
| ZON | HOLD | 06/06/2022 | 06/08/2022 |
| Note: Held By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM On site plan submitted the A/C pad is missing. Please include that in your plans If your mechanical equipment is encroaching then you will need to fill out the 2' encroachment agreement | |||
| SWALE | COMPLETE | 06/06/2022 | 08/30/2022 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| PLAN REVIEW - REVISION | ¤32.50 | 05/02/2025 |
| PLAN REVIEW - REVISION | ¤32.50 | 05/02/2025 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 05/02/2025 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 05/02/2025 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 05/02/2025 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 05/02/2025 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 05/02/2025 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 05/02/2025 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 05/02/2025 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 05/02/2025 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 05/02/2025 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 05/02/2025 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 05/02/2025 |
| CONTRACTOR CHANGE | ¤20.00 | 05/02/2025 |
| CONTRACTOR CHANGE | ¤20.00 | 05/02/2025 |
| CONTRACTOR CHANGE | ¤100.00 | 05/02/2025 |
| CONTRACTOR CHANGE | ¤20.00 | 05/02/2025 |
| REINSPECTION FEE | ¤40.00 | 05/02/2025 |
| SURCHARGE FS 533.721 | ¤4.14 | 11/03/2022 |
| SURCHARGE - FS 468.631 | ¤6.21 | 11/03/2022 |
| SW ENG - FOUNDATION SURVEY | ¤20.00 | 11/03/2022 |
| SW ENG INSPECTION 80 | ¤80.00 | 11/03/2022 |
| SW ENG PRE APRON | ¤30.00 | 11/03/2022 |
| SW ENG - REVIEW 20 | ¤20.00 | 11/03/2022 |
| SW ENG RES REVIEW 200 | ¤200.00 | 11/03/2022 |
| 3% TRANS IMPACT FEE CREDIT | (¤52.92) | 11/03/2022 |
| SEWER INSPECTION | ¤25.00 | 11/03/2022 |
| SEWER CAPITAL FACILITY | ¤4,939.76 | 11/03/2022 |
| WATER CREDIT | (¤1,146.32) | 11/03/2022 |
| WATER CAPITAL FACILITY FEE | ¤3,626.50 | 11/03/2022 |
| SITE PLAN 30 | ¤30.00 | 11/03/2022 |
| WATER- TURN ON | ¤25.00 | 11/03/2022 |
| ADJUSTMENT 50% | (¤657.46) | 11/03/2022 |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | 11/03/2022 |
| INSPECTION - RESIDENTIAL | ¤1,001.00 | 11/03/2022 |
| PLAN REVIEW - RESIDENTIAL | ¤283.92 | 11/03/2022 |
| 3% FIRE IMPACT FEE CREDIT | (¤11.66) | 11/03/2022 |
| IMPACT FEE FIRE | ¤388.65 | 11/03/2022 |
| IMPACT FEE PARKS | ¤1,455.13 | 11/03/2022 |
| IMPACT FEE SCHOOL | ¤3,600.00 | 11/03/2022 |
| IMPACT FEE TRANSPORTATION | ¤1,764.00 | 11/03/2022 |
| WATER -IRRIGATION INSPECTION | ¤25.00 | 11/03/2022 |
| 3% PARKS IMPACT FEE CREDIT | (¤43.65) | 11/03/2022 |
| CONNECTION FEES | ¤1,077.88 | 11/03/2022 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤17,425.18 |