I want to search for...

Permit #2022060775

Permit Details

Status: CANCEL

Parcel Id: 07-11-31-7032-00690-0130
Block: 00690
Subdivision: 2155 - SECTION 32-ROYAL PALMS
Job Phone: 321-332-0001
Location Address: 32 ROXBORO DR
Type: ME - MECHANICAL
Issue Date: 06/14/2022
NOC: RECORDED
Applicant name: VICTOR HARDY SMITH JR
Owner: WOOD WILLIAM B III & JEANNE D WOOD

Address

32 ROXBORO DR

PALM COAST, FL 32164

Lot: 0130
Contracted Stated Job Value: ¤8,200.00
Job Description: HVAC LIKE FOR LIKE TONNAGE
Type: CN

Contractor

SERVICE EXPERTS HEATING & AIR CONDITIONING
Status Location Address Mailing Address State License Number Phone
CANCEL

1412 INTREPID DR

DELAND, FL 32724

UNIT C

DELAND, FL 32724

CAC1816603 (Exp: 08/31/2026) 321-332-0001

Inspection History

Type Request Date Result Inspector
HVAC FINAL 08/18/2022 Disapproved -FEE REQUIRED JWALKER
Note: 8/18/22 The labeling has been address from the first inspection. The marked of AHU label call for a 30 amp max breaker. 4O amp installed at the electrical panel. The outdoor unit calls for a 25 amp max breaker. Again a 40 amp is installed at the panel.
HVAC FINAL 07/12/2022 Disapproved -FEE REQUIRED CPISCITELLI
Note: 1. UNIT LABELING..FBC.R. M1303.1 MUST IDENTIFY MAXIMUM OVER CURRENT BREAKER SIZE ON AIR HANDLER UNIT WITH FACTORY APPLIED LABEL. (Need to mark heater. Unable to verify breaker in panel). 2. IDENTIFY A/C AND OR AHU BREAKERS IN PANEL, E3706.2 ALL CIRCUITS SHALL BE LEGIBLY IDENTIFIED AS TO THEIR CLEAR, EVIDENT, AND SPECIFIC PURPOSE OR USE. (Need to verify breakers in panel for AC and Heat. Multiple units)
HVAC FINAL
Note: THIS IS A REINSPECTION 8/18/22 The labeling has been address from the first inspection. The marked of AHU label call for a 30 amp max breaker. 4O amp installed at the electrical panel. The outdoor unit calls for a 25 amp max breaker. Again a 40 amp is installed at the panel.

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
REINSPECTION RESIDENTIAL ¤40.00 08/17/2022
SURCHARGE FS 533.721 ¤2.00 06/14/2022
SURCHARGE - FS 468.631 ¤2.00 06/14/2022
ADMINISTRATIVE RESIDENTIAL ¤30.00 06/14/2022
INSPECTION - MECHANICAL ¤60.00 06/14/2022
Fees Total Due: ¤0.00 Total Paid: ¤134.00