I want to search for...

Permit #2022060932

Permit Details

Status: COED

Parcel Id: 07-11-31-7030-00110-0100
CONDITIONED SPACE: 1900 sqft
GARAGE: 471 sqft
OPENED PORCH (WITH ROOF) : 24 sqft
OPENED PORCH (WITH ROOF) : 144 sqft
Total Square Footage: 2539 sqft
Block: 00110
Subdivision: 2154 - SECTION 30-ROYAL PALMS
Job Phone: 912-258-2201
Location Address: 2 RAEITAN WAY
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 12/15/2022
NOC: RECORDED
Applicant name: JAMES FUCETOLA III
Owner: PALM COAST COMMUNITIES LLC

Address

PO BOX 22547

ST SIMONS ISLAND, GA 31522

Lot: 0100
Contracted Stated Job Value: ¤170,000.00
Job Description: Single Family Residence
Type: CN

Contractor

PALM COAST COMMUNITIES LLC
Status Location Address State License Number Phone
INACTIVE

PO BOX 22547

PALM COAST, FL 32164

CBC1262878 (Exp: 08/31/2026) 321-501-4617

Sub Contractors

WILLIAM FRANK DUDLEY JR.
Status Location Address State License Number Phone
ACTIVE

P.O. BOX 978

Bunnell, FL 32110

EC0003177 (Exp: 08/31/2026) (386)437-3068
OLEG BELINSKIY
Status Location Address State License Number Phone
ACTIVE

19 PINE CIRCLE DRIVE19

PALM COAST, FL 32167

CCC1325974 (Exp: 08/31/2026) 386-263-7906
GARY LLOYD SHEFFIELD
Status Location Address State License Number Phone
ACTIVE

48 EAGLE LAKES DRIVE

FLAGLER BEACH, FL 32136

CAC048127 (Exp: 08/31/2026) 386-597-3280
JEFFREY TROY SABAKA
Status Location Address State License Number Phone Fax
ACTIVE

2191 DEERWOOD ACRES DR

ST AUGUSTINE, FL 32084

CFC1427439 (Exp: 08/31/2026) 904-838-2218 904-819-0965

Inspection History

Type Request Date Result Inspector
BLD - BUILDING FINAL 08/09/2023 FINAL APPROVED JWALKER
Note: 8/8/2023 - PREVIOUS INSPECTION NOTES 8/8/23 Item 1 has not been corrected. 8/7/2023 - PREVIOUS INSPECTION NOTES 1. AHU calls for a max circuit breaker of 30 amps. A 35 amp has been installed. 2. The hot and cold water at the master bath shower is reversed.
BLD - BUILDING FINAL 08/08/2023 Disapproved - NO FEE JWALKER
Note: 8/8/23 Item 1 has not been corrected. 8/7/2023 - PREVIOUS INSPECTION NOTES 1. AHU calls for a max circuit breaker of 30 amps. A 35 amp has been installed. 2. The hot and cold water at the master bath shower is reversed.
BLD - BUILDING FINAL 08/07/2023 Disapproved - NO FEE JWALKER
Note: 1. AHU calls for a max circuit breaker of 30 amps. A 35 amp has been installed. 2. The hot and cold water at the master bath shower is reversed.
U -UTILITY RESIDENTIAL FINAL 08/07/2023 FINAL APPROVED LFITZGERALD
ROW FIELD SURVEY /GRADING CERTIFICATION 08/04/2023 APPROVED RGROSS
Note: 7/24/2023 - PREVIOUS INSPECTION NOTES 7/24/23= LEFT SIDE SWALE NEED TO BE LOWER YOU ARE STOPING THE FLOW OF THE WATER LEFT SIDE SWALE ON RAEMOOR DR HAS A HIGH SPOTS STOPING THE FLOW OF THE WATER
ROW - STORMWATER FINAL 08/04/2023 APPROVED RGROSS
ROW - FINAL APRON (AFTER POUR) 08/04/2023 APPROVED RGROSS
ROW- FINAL SURVEY/GRADING CERTIFICATION 07/24/2023 APPROVED GBERTOLA
Note: At the time of the inspection all minimum city requirements were met. It is the builders responsibility to ensure that nothing changes after this Inspection is approved.
ROW FIELD SURVEY /GRADING CERTIFICATION 07/24/2023 Disapproved -FEE REQUIRED GBERTOLA
Note: 7/24/23= LEFT SIDE SWALE NEED TO BE LOWER YOU ARE STOPING THE FLOW OF THE WATER LEFT SIDE SWALE ON RAEMOOR DR HAS A HIGH SPOTS STOPING THE FLOW OF THE WATER
U-CROSS CONNECTION 06/30/2023 APPROVED DHANEY
ROW- PRE-APRON (PRE-POUR) 06/13/2023 APPROVED FSLADISH
Note: 06/13/23 PIPE IS GOOD. READY FOR POUR AT TIME OF INSPECTION. AT THE TIME OF THE INSPECTION CULVERT PIPE IS GOOD IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD DOUBLE CHECK CULVERT ELEVATIONS BEFORE POURING. MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL
U - SEWER TIE IN 05/31/2023 APPROVED - AS NOTED MGIBSON
Note: THIS WAS A VIRTUAL INSPECTION
ELECTRIC - EARLY POWER 05/30/2023 APPROVED LMILLER
Note: 5/26/2023 - PREVIOUS INSPECTION NOTES 5/26/23 Below listed corrections have not been made. Notes below resolved 5/25/2023 - PREVIOUS INSPECTION NOTES 1. The 12-2 wire hanging out the right side exterior wall is not safed off. 2. The dishwasher / garbage disposal outlet under the kitchen sink will need to be moved to a readily accessible location.
ELECTRIC - EARLY POWER 05/26/2023 Disapproved -FEE REQUIRED JWALKER
Note: 5/26/23 Below listed corrections have not been made. 5/25/2023 - PREVIOUS INSPECTION NOTES 1. The 12-2 wire hanging out the right side exterior wall is not safed off. 2. The dishwasher / garbage disposal outlet under the kitchen sink will need to be moved to a readily accessible location.
ELECTRIC - EARLY POWER 05/25/2023 Disapproved - NO FEE JWALKER
Note: 1. The 12-2 wire hanging out the right side exterior wall is not safed off. 2. The dishwasher / garbage disposal outlet under the kitchen sink will need to be moved to a readily accessible location.
PEP TANK INSTALLATION REQUEST 05/09/2023 APPROVED CSTONE
PEP TANK INSTALLATION REQUEST 04/27/2023 APPROVED CSTONE
INSULATION 04/26/2023 APPROVED JWALKER
Note: Remove bonding screw from the interior electrical panel. Support and seal the bathroom exhaust fan ducts. Toilet fan not wired. Seal the retun plenum box under the support box. Check for corrections at insulation.
ALL ROUGH 04/21/2023 APPROVED - AS NOTED JWALKER
Note: Remove bonding screw from the interior electrical panel. Support and seal the bathroom exhaust fan ducts. Toilet fan not wired. Seal the retun plenum box under the support box. Check for corrections at insulation.
LATH/BRICK/ WATER BARRIER 04/20/2023 APPROVED MKRASKI
ROOF VALLEY & METAL 03/23/2023 APPROVED JWALKER
WALL SHEATHING 03/21/2023 APPROVED JWALKER
ROOF SHEATHING / BRACES/TIES/DOWN CELL 03/21/2023 APPROVED JWALKER
FOUND SURVEY APPROVED (OFFICE) 03/15/2023 APPROVED TBAKER
TIE BEAM / LINTEL 03/07/2023 APPROVED JWALKER
MONOLITHIC SLAB 02/24/2023 APPROVED JWALKER
Note: 2/23/2023 - PREVIOUS INSPECTION NOTES 2/23/23: Step down footing area is not done per plan detail. Not sized properly and missing (1) #5 rebar as shown in detail. Highlighted on plans. 1/30/2023 - PREVIOUS INSPECTION NOTES Please provide a detail for the step down footing area at the garage interior walls.
MONOLITHIC SLAB 02/23/2023 Disapproved -FEE REQUIRED RSIMS
Note: 2/23/23: Step down footing area is not done per plan detail. Not sized properly and missing (1) #5 rebar as shown in detail. Highlighted on plans. 1/30/2023 - PREVIOUS INSPECTION NOTES Please provide a detail for the step down footing area at the garage interior walls.
MONOLITHIC SLAB 01/30/2023 Disapproved - NO FEE JWALKER
Note: Please provide a detail for the step down footing area at the garage interior walls.
PLUMBING 1ST ROUGH UNDERGROUND 01/26/2023 APPROVED MGIBSON
GRAVITY SEWER TEST 01/26/2023 APPROVED MGIBSON
WATER METER INSTALLATION REQUEST 01/03/2023 APPROVED CSTONE

Review History

Department Status Date In Date Out
BADMIN INFORMATION 03/22/2023 03/22/2023
Note: Marked INFORMATION By: MICHELLE RAMOS - - MRAMOS@PALMCOASTGOV.COM NOC is expired
ENGIN1 COMPLETE 03/10/2023 03/15/2023
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
ZON COMPLETE 03/10/2023 03/10/2023
Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM
BLD COMPLETE 02/24/2023 02/27/2023
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
BLD COMPLETE 02/22/2023 02/22/2023
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
BLD HOLD 02/13/2023 02/15/2023
Note: Held By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM All comments below per the 2020 Florida Building Code PLAN REVIEW COMMENTS: 1. Revised Sheet 4/6 calls-out Detail 8/F for the proposed Garage footing. Detail 8/F on Sheet 5/6 is for a thickened edge @ patio. Revise to reflect the correct Detail for the Garage wall.
BLD HOLD 02/07/2023 02/10/2023
Note: Held By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM All comments below per the 2020 Florida Building Code REVIEW COMMENTS: 1. The revision submitted for the Foundation Plan shows the proposed structure was flipped. A revision to the Floor Plan and Elevations will be required. FBC 107
ZON COMPLETE 06/30/2022 06/30/2022
Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM
SWALE COMPLETE 06/16/2022 09/14/2022
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
BLD COMPLETE 06/15/2022 06/21/2022
Note: Released By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM
CUSVC COMPLETE 06/15/2022 06/17/2022
Note: Released By: CYNTHIA SCHWEERS - - CSCHWEERS@PALMCOASSTGOV.COM
ELEC COMPLETE 06/15/2022 06/16/2022
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
ENGIN1 COMPLETE 06/15/2022 06/16/2022
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
LOCATE COMPLETE 06/15/2022 06/21/2022
Note: Released By: CANDACE STONE - - CSTONE@PALMCOASTGOV.COM
MECH COMPLETE 06/15/2022 06/16/2022
Note: Released By: CHRIS PISCITELLI - (386)986-3782 - CPISCITELLI@PALMCOASTGOV.COM
SW1 COMPLETE 06/15/2022 06/23/2022
Note: Released By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM PLEASE READ SITE PLAN FOR NEW DRAINAGE ON LOT
ZON HOLD 06/15/2022 06/21/2022
Note: Held By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM Banding around Windows and doors All windows and doors facing public right of way must have banding. Please put bands on right side ROW Landscape plan: *Six Shrubs shall be planted on each side of the home facing the street

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
PLAN REVIEW - REVISION ¤32.50 08/09/2023
REINSPECTION RESIDENTIAL ¤40.00 08/09/2023
REINSPECTION RESIDENTIAL ¤40.00 08/09/2023
SW ENG REINSPECTION 20 ¤20.00 08/09/2023
SW ENG - REVIEW 20 ¤20.00 12/15/2022
SW ENG RES REVIEW 200 ¤200.00 12/15/2022
3% TRANS IMPACT FEE CREDIT (¤52.92) 12/15/2022
SEWER CREDIT (¤1,147.00) 12/15/2022
SEWER INSPECTION ¤25.00 12/15/2022
SEWER CAPITAL FACILITY ¤4,939.76 12/15/2022
WATER CAPITAL FACILITY FEE ¤3,626.50 12/15/2022
SITE PLAN 30 ¤30.00 12/15/2022
WATER- TURN ON ¤25.00 12/15/2022
ADJUSTMENT 50% (¤433.31) 12/15/2022
ADMINISTRATIVE RESIDENTIAL ¤30.00 12/15/2022
INSPECTION - RESIDENTIAL ¤651.75 12/15/2022
PLAN REVIEW - RESIDENTIAL ¤184.86 12/15/2022
CONNECTION FEES ¤1,077.88 12/15/2022
3% FIRE IMPACT FEE CREDIT (¤11.66) 12/15/2022
IMPACT FEE FIRE ¤388.65 12/15/2022
IMPACT FEE PARKS ¤1,455.13 12/15/2022
IMPACT FEE SCHOOL ¤3,600.00 12/15/2022
IMPACT FEE TRANSPORTATION ¤1,764.00 12/15/2022
WATER -IRRIGATION INSPECTION ¤25.00 12/15/2022
3% PARKS IMPACT FEE CREDIT (¤43.65) 12/15/2022
SURCHARGE FS 533.721 ¤2.86 12/15/2022
SURCHARGE - FS 468.631 ¤4.28 12/15/2022
SW ENG - FOUNDATION SURVEY ¤20.00 12/15/2022
SW ENG INSPECTION 80 ¤80.00 12/15/2022
SW ENG PRE APRON ¤30.00 12/15/2022
Fees Total Due: ¤0.00 Total Paid: ¤16,624.63