Permit #2022061182

Permit Details

Status: COED

Parcel Id: 07-11-31-7021-00200-0300
CONDITIONED SPACE: 1517 sqft
GARAGE: 394 sqft
Total Square Footage: 1911 sqft
Block: 00200
Subdivision: 2186 - SECTION 21-WYNNFIELD
Job Phone: 470-817-1259
Location Address: 44 WELLSTONE DR
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 08/02/2022
NOC: RECORDED
Applicant name: WADE GILMER JURNEY JR
Owner: NATIONAL HOME CORPORATION

Address

4850 TAMIAMI TRAIL NORTH

NAPLES, FL 34103

Lot: 0300
Contracted Stated Job Value: ¤208,353.00
Job Description: SINGLE FAMILY RESIDENCE
Type: CN

Contractor

NATIONAL HOME CORPORATION
Status Location Address Mailing Address State License Number Phone
INACTIVE

1080 HOLCOMB BRIDGE ROAD

,

BLDG 100 - 330

ROSWELL , GA 30076

CBC1257700 (Exp: 08/31/2026) 471-817-1259

Sub Contractors

DUSTIN L ESTEP
Status Location Address State License Number Phone Fax
ACTIVE

2041 N HIAWASSEE RD

APOPKA, FL 32703

CCC1330971 (Exp: 08/31/2026) 407-702-0206 352-988-6629
JASON PATRICK RIBOCK
Status Location Address State License Number Phone
INACTIVE

620 E PINE ST

, 0

ES12001313 (Exp: 08/31/2026) 407-625-0257
RUSSELL J CARTER
Status Location Address State License Number Phone Fax
ACTIVE

PO BOX 302

DELAND, FL 32721

CFC1425938 (Exp: 08/31/2026) 386-736-4220 386-736-4219
RANDALL SCOTT ROSENFELD
Status Location Address State License Number Phone
ACTIVE

234 N WHITNEY ST

PALM COAST, FL 32084

CAC1816641 (Exp: 08/31/2026) 904-599-0082

Inspection History

Type Request Date Result Inspector
BLD - BUILDING FINAL 08/25/2023 Disapproved - NO FEE JWALKER
Note: 1. Energy calculations not onsite. 2. Seal the garage wall right of garage door side where conduit comes through for exterior light fixture.
BLD - BUILDING FINAL 08/25/2023 FINAL APPROVED JWALKER
Note: Contractor showed up with cals and sealed hole. 8/25/2023 - PREVIOUS INSPECTION NOTES 1. Energy calculations not onsite. 2. Seal the garage wall right of garage door side where conduit comes through for exterior light fixture.
BLD - BUILDING FINAL 08/23/2023 CANCELLED BY APPLICANT MKRASKI
U -UTILITY RESIDENTIAL FINAL 08/23/2023 FINAL APPROVED LFITZGERALD
Note: 8/22/2023 - PREVIOUS INSPECTION NOTES sewer clean out riser pipe needs to be cut down flush with grades
U -UTILITY RESIDENTIAL FINAL 08/22/2023 Disapproved -FEE REQUIRED LFITZGERALD
Note: sewer clean out riser pipe needs to be cut down flush with grades
ROW- FINAL SURVEY/GRADING CERTIFICATION 08/21/2023 APPROVED GBERTOLA
Note: 8/21/23= CORRECTION WERE MADE At the time of the inspection, all minimum city requirements were met. It is the builder's responsibility to ensure that nothing changes after this Inspection is approved.
ROW FIELD SURVEY /GRADING CERTIFICATION 08/21/2023 APPROVED GBERTOLA
Note: CORRECTION WERE MADE At the time of the inspection, all minimum city requirements were met. It is the builder's responsibility to ensure that nothing changes after this Inspection is approved.
ROW - STORMWATER FINAL 08/21/2023 APPROVED GBERTOLA
Note: At the time of the inspection, all minimum city requirements were met. It is the builder's responsibility to ensure that nothing changes after this Inspection is approved.
U-CROSS CONNECTION 08/21/2023 APPROVED - AS NOTED LFITZGERALD
Note: no irrigation-no cross connection
ROW - FINAL APRON (AFTER POUR) 08/21/2023 APPROVED GBERTOLA
Note: At the time of the inspection, all minimum city requirements were met. It is the builder's responsibility to ensure that nothing changes after this Inspection is approved.
U - SEWER TIE IN 08/21/2023 APPROVED - AS NOTED MGIBSON
Note: 7/20/2023 - PREVIOUS INSPECTION NOTES Can not see tie in THIS WAS A VIRTUAL INSPECTION
ROW- FINAL SURVEY/GRADING CERTIFICATION 08/16/2023 Disapproved - NO FEE FSLADISH
Note: 08/16/23 REAR RIGHT FROM BACK OF PROPERTY IS ALL FLOWING ONTO RIGHT SIDE ADJACENT PROPERTY CAUSING A NEGATIVE DRAINAGE ISSUE. IT GOES FROM A 31.10 TO 31.10 TO 30.8 TO ? AS THERE IS NO ELEVATION SHOT, BUT IT IS DEFINITELY FLOWING ONTO THE PROPERTY BASED ON THE TWO SHOTS IT FALLS BETWEEN 28.50 PROPERTY LINE REAR RIGHT AND 29.50 FIRST OFFSET ELEVATION SHOT. The subject lots drainage must not negatively impact any adjacent property. (J) J.Land Development Code Technical Manual, Section 300.01 (A)(1)(C)(6)
ROW FIELD SURVEY /GRADING CERTIFICATION 08/10/2023 Disapproved - NO FEE FSLADISH
Note: 08/10/23 YOU MUST FIRST PUT IN A FINAL SURVEY AND PASS THAT INSPECTION BEFORE YOU CAN HAVE A FIELD SURVEY INSPECTION SCHEDULED. I AM NOT GOING TO FEE YOU TODAY. PLEASE SUBMIT A FINAL SURVEY FOR REVIEW. ________________________________________________________________________________________________________________________ Inspector Notes from Inspection 9270 7/5/23= AT THE TIME OF THE INSPECTION CULVERT PIPE IS GOOD IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD DOUBLE CHECK CULVERT ELEVATIONS BEFORE POURING. MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 6/27/2023 - PREVIOUS INSPECTION NOTES **06/27/23 Sec.900.04A Driveway thickness on the right-of-way shall be either six inches (6") on firmly compacted subgrade of clean granular material or five inches (5") on three inches (3") of limerock or shell base. ALL THE WAY OUT TO EDGE OF ROAD **FOOTERS NEED TO BE RE-DUG 6X6X18 ** REMOVE EXCESS MATERIAL FROM AROUND CULVERT NEEDS TO BE BURIED AND COMPACTED HALF WAY UP _________________________________________________________________________________________________________________________ 6/23/2023 - PREVIOUS INSPECTION NOTES ** 06/23/23 SITE IS UNDER WATER AT THE TIME OF INSPECTION NOT READY ** SEE ATTACHED PHOTOS _____________________________________________________________________________________________________________________ 6/8/2023 - PREVIOUS INSPECTION NOTES 06/08/23 THE RIGHT SIDE DRIVEWAY APRON WING FORMBOARD NEEDS TO BE A MINIMUM WIDTH OF 36" PLEASE SEE PICTURE FOR REFERENCE. I WILL NOT FEE YOU TODAY, PLEASE FIX. PIPE IS GOOD.
U - SEWER TIE IN 07/20/2023 Disapproved - NO FEE MKRASKI
Note: Can not see tie in
U-CROSS CONNECTION 07/20/2023 CANCELLED BY APPLICANT WEB
ROW- PRE-APRON (PRE-POUR) 07/05/2023 APPROVED - AS NOTED GBERTOLA
Note: 7/5/23= AT THE TIME OF THE INSPECTION CULVERT PIPE IS GOOD IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD DOUBLE CHECK CULVERT ELEVATIONS BEFORE POURING. MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 6/27/2023 - PREVIOUS INSPECTION NOTES **06/27/23 Sec.900.04A Driveway thickness on the right-of-way shall be either six inches (6") on firmly compacted subgrade of clean granular material or five inches (5") on three inches (3") of limerock or shell base. ALL THE WAY OUT TO EDGE OF ROAD **FOOTERS NEED TO BE RE-DUG 6X6X18 ** REMOVE EXCESS MATERIAL FROM AROUND CULVERT NEEDS TO BE BURIED AND COMPACTED HALF WAY UP _________________________________________________________________________________________________________________________ 6/23/2023 - PREVIOUS INSPECTION NOTES ** 06/23/23 SITE IS UNDER WATER AT THE TIME OF INSPECTION NOT READY ** SEE ATTACHED PHOTOS _____________________________________________________________________________________________________________________ 6/8/2023 - PREVIOUS INSPECTION NOTES 06/08/23 THE RIGHT SIDE DRIVEWAY APRON WING FORMBOARD NEEDS TO BE A MINIMUM WIDTH OF 36" PLEASE SEE PICTURE FOR REFERENCE. I WILL NOT FEE YOU TODAY, PLEASE FIX. PIPE IS GOOD.
ROW- PRE-APRON (PRE-POUR) 06/27/2023 Disapproved -FEE REQUIRED EMADISON
Note: **06/27/23 Sec.900.04A Driveway thickness on the right-of-way shall be either six inches (6") on firmly compacted subgrade of clean granular material or five inches (5") on three inches (3") of limerock or shell base. ALL THE WAY OUT TO EDGE OF ROAD **FOOTERS NEED TO BE RE-DUG 6X6X18 ** REMOVE EXCESS MATERIAL FROM AROUND CULVERT NEEDS TO BE BURIED AND COMPACTED HALF WAY UP _________________________________________________________________________________________________________________________ 6/23/2023 - PREVIOUS INSPECTION NOTES ** 06/23/23 SITE IS UNDER WATER AT THE TIME OF INSPECTION NOT READY ** SEE ATTACHED PHOTOS _____________________________________________________________________________________________________________________ 6/8/2023 - PREVIOUS INSPECTION NOTES 06/08/23 THE RIGHT SIDE DRIVEWAY APRON WING FORMBOARD NEEDS TO BE A MINIMUM WIDTH OF 36" PLEASE SEE PICTURE FOR REFERENCE. I WILL NOT FEE YOU TODAY, PLEASE FIX. PIPE IS GOOD.
ROW- PRE-APRON (PRE-POUR) 06/23/2023 Disapproved -FEE REQUIRED EMADISON
Note: ** 06/23/23 SITE IS UNDER WATER AT THE TIME OF INSPECTION NOT READY ** SEE ATTACHED PHOTOS _____________________________________________________________________________________________________________________ 6/8/2023 - PREVIOUS INSPECTION NOTES 06/08/23 THE RIGHT SIDE DRIVEWAY APRON WING FORMBOARD NEEDS TO BE A MINIMUM WIDTH OF 36" PLEASE SEE PICTURE FOR REFERENCE. I WILL NOT FEE YOU TODAY, PLEASE FIX. PIPE IS GOOD.
ELECTRIC - EARLY POWER 06/23/2023 APPROVED - AS NOTED MKRASKI
Note: Emailed FPL @ 9:20 AM
ROW- PRE-APRON (PRE-POUR) 06/08/2023 Disapproved - NO FEE FSLADISH
Note: 06/08/23 THE RIGHT SIDE DRIVEWAY APRON WING FORMBOARD NEEDS TO BE A MINIMUM WIDTH OF 36" PLEASE SEE PICTURE FOR REFERENCE. I WILL NOT FEE YOU TODAY, PLEASE FIX. PIPE IS GOOD.
INSULATION 05/17/2023 APPROVED RMARTIN
Note: 5/9/2023 - PREVIOUS INSPECTION NOTES 5/9/23: 1). Missing Firestop at Horizontal wire runs over 10ft. Per FBC 302.11: Required Locations (1.2. Horizontally at intervals not exceeding 10 feet (3048 mm)). Marked on studs with FS where required. 2). Master Bathroom - Missing firestop at bathtub pack out wall as required. 3). Hallway Bathroom - Missing firestop at top plate penetration for wire. (Marked with FS on stud below). 4). Garage door - spray foam insulation is incomplete. (gaps allowing air space).
INSULATION 05/09/2023 Disapproved -FEE REQUIRED RSIMS
Note: 5/9/23: 1). Missing Firestop at Horizontal wire runs over 10ft. Per FBC 302.11: Required Locations (1.2. Horizontally at intervals not exceeding 10 feet (3048 mm)). Marked on studs with FS where required. 2). Master Bathroom - Missing firestop at bathtub pack out wall as required. 3). Hallway Bathroom - Missing firestop at top plate penetration for wire. (Marked with FS on stud below). 4). Garage door - spray foam insulation is incomplete. (gaps allowing air space).
ELECTRIC TEMP POLE 04/28/2023 Disapproved -FEE REQUIRED MKRASKI
Note: No temp pole set
ALL ROUGH 04/20/2023 APPROVED MKRASKI
ALL ROUGH 04/10/2023 Disapproved -FEE REQUIRED MKRASKI
Note: 4/10/23 1. Garage door buck anchors still missing per detail 2. Failed 5' head pressure test 3. Nail plate required for drain line in spare bathroom 3/22/2023 - PREVIOUS INSPECTION NOTES 3/22/23 ALL repairs must be made from previous inspection before reinspection 3/8/2023 - PREVIOUS INSPECTION NOTES 1. Over head service wires undersized 2. Overhead service wires not sun light resistant 3. Romex above electrical panel needs to be strapped within 12'' of the panel 4. Garage dopor bucks missing anchors Stopped inspection @ garage
ALL ROUGH 03/22/2023 Disapproved -FEE REQUIRED MKRASKI
Note: 3/22/23 ALL repairs must be made from previous inspection before reinspection 3/8/2023 - PREVIOUS INSPECTION NOTES 1. Over head service wires undersized 2. Overhead service wires not sun light resistant 3. Romex above electrical panel needs to be strapped within 12'' of the panel 4. Garage dopor bucks missing anchors Stopped inspection @ garage
ALL ROUGH 03/16/2023 CANCELLED BY APPLICANT WEB
Note: 3/8/2023 - PREVIOUS INSPECTION NOTES 1. Over head service wires undersized 2. Overhead service wires not sun light resistant 3. Romex above electrical panel needs to be strapped within 12'' of the panel 4. Garage dopor bucks missing anchors Stopped inspection @ garage
LATH/BRICK/ WATER BARRIER 03/10/2023 APPROVED MKRASKI
ALL ROUGH 03/08/2023 Disapproved -FEE REQUIRED MKRASKI
Note: 1. Over head service wires undersized 2. Overhead service wires not sun light resistant 3. Romex above electrical panel needs to be strapped within 12'' of the panel 4. Garage dopor bucks missing anchors Stopped inspection @ garage
ALL ROUGH 03/07/2023 Disapproved -FEE REQUIRED MKRASKI
Note: Previous repairs not made, stopped inspection New inspection due to canceled inspection Inspector Notes from Inspection 2467 Missing H8 clip on gable bracing per detail Check on next inspection
ALL ROUGH 03/06/2023 CANCELLED BY APPLICANT WEB
Note: Inspector Notes from Inspection 2467 Missing H8 clip on gable bracing per detail Check on next inspection
ROOF VALLEY & METAL 02/14/2023 APPROVED - AS NOTED MKRASKI
Note: Missing H8 clip on gable bracing per detail Check on next inspection
WALL SHEATHING 02/07/2023 APPROVED MKRASKI
ROOF SHEATHING / BRACES/TIES/DOWN CELL 02/07/2023 APPROVED - AS NOTED MKRASKI
Note: Missing H8 clip on gable bracing per detail Check on next inspection
FOUND SURVEY APPROVED (OFFICE) 02/07/2023 APPROVED JHOWARD
TIE BEAM / LINTEL 01/31/2023 APPROVED MKRASKI
TIE BEAM / LINTEL 01/30/2023 Disapproved - NO FEE MKRASKI
Note: Dowel within 2'' of the face of the block, marked with orange paint, Back right corner FBC 606.13.5
MONOLITHIC SLAB 01/18/2023 APPROVED MKRASKI
MONOLITHIC SLAB 01/17/2023 Disapproved - NO FEE MKRASKI
Note: Ufer needs to be stubbed up into a cell for access
PLUMBING 1ST ROUGH UNDERGROUND 01/10/2023 APPROVED MGIBSON
GRAVITY SEWER TEST 01/10/2023 APPROVED MGIBSON
WATER METER INSTALLATION REQUEST 09/06/2022 APPROVED CSTONE

Review History

Department Status Date In Date Out
BADMIN INFORMATION 06/16/2023 06/16/2023
Note: Marked INFORMATION By: SCOTT THOMAS - - STHOMAS@PALMCOASTGOV.COM RENAME TO NOC.PDF
BADMIN INFORMATION 06/16/2023 06/16/2023
Note: Marked INFORMATION By: SCOTT THOMAS - - STHOMAS@PALMCOASTGOV.COM RENAME TO NOC.PDF
BADMIN INFORMATION 06/16/2023 06/16/2023
Note: Marked INFORMATION By: SCOTT THOMAS - - STHOMAS@PALMCOASTGOV.COM NOC MISSING NOTARY AT BOTTOM
MECH COMPLETE 02/08/2023 02/08/2023
Note: Released By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM
MECH HOLD 02/03/2023 02/06/2023
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Duct layout needs to be signed by the AC contractor per 107.1 FBC Residential 2020 7th Edition (Second Request)
ENGIN1 COMPLETE 02/03/2023 02/06/2023
Note: Released By: JOHN HOWARD - - JHOWARD@PALMCOASTGOV.COM
ZON COMPLETE 02/03/2023 02/03/2023
Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM
MECH HOLD 02/02/2023 02/03/2023
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Duct layout needs to be signed by the AC contractor per 107.1 FBC Residential 2020 7th Edition
ZON COMPLETE 06/30/2022 06/30/2022
Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM
BLD COMPLETE 06/30/2022 07/05/2022
Note: Released By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM
SW1 COMPLETE 06/30/2022 07/07/2022
Note: Released By: ROBERT GROSS - (386)986-4769 - RGROSS@PALMCOASTGOV.COM
BLD HOLD 06/21/2022 06/23/2022
Note: Held By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM All comments below per the 2020 Florida Building Code REVIEW COMMENTS: 1. Plans submitted are noted as a Master Plan. There is no Master Plan on file.
CUSVC COMPLETE 06/21/2022 06/23/2022
Note: Released By: HALEIGH HAND - -
ELEC COMPLETE 06/21/2022 06/21/2022
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
ENGIN1 COMPLETE 06/21/2022 06/21/2022
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
LOCATE COMPLETE 06/21/2022 06/24/2022
Note: Released By: CANDACE STONE - - CSTONE@PALMCOASTGOV.COM
MECH COMPLETE 06/21/2022 06/21/2022
Note: Released By: CHRIS PISCITELLI - (386)986-3782 - CPISCITELLI@PALMCOASTGOV.COM
SW1 HOLD 06/21/2022 06/27/2022
Note: Held By: EDWARD MADISON - - EMADISON@PALMCOASTGOV.COM need to have the proposed elevation across the from row showing property line os equal or greater than the centerline of road.
ZON HOLD 06/21/2022 06/22/2022
Note: Held By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM One additional shrub required around AC for screening
SWALE COMPLETE 06/21/2022 09/19/2022
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
REINSPECTION RESIDENTIAL ¤40.00 08/25/2023
REINSPECTION RESIDENTIAL ¤40.00 08/25/2023
REINSPECTION FEE ¤40.00 08/25/2023
SW ENG REINSPECTION 30 ¤30.00 08/25/2023
SW ENG REINSPECTION 30 ¤30.00 08/25/2023
REINSPECTION RESIDENTIAL ¤40.00 04/13/2023
REINSPECTION RESIDENTIAL ¤40.00 04/13/2023
REINSPECTION RESIDENTIAL ¤40.00 04/13/2023
REINSPECTION RESIDENTIAL ¤40.00 04/13/2023
CONTRACTOR CHANGE ¤40.00 01/04/2023
CONTRACTOR CHANGE ¤20.00 01/04/2023
IMPACT FEE FIRE ¤388.65 08/02/2022
IMPACT FEE PARKS ¤1,455.13 08/02/2022
ADMINISTRATIVE RESIDENTIAL ¤30.00 08/02/2022
PLAN REVIEW - RESIDENTIAL ¤163.02 08/02/2022
CONNECTION FEES ¤1,077.88 08/02/2022
3% FIRE IMPACT FEE CREDIT (¤11.66) 08/02/2022
WATER- TURN ON ¤25.00 08/02/2022
INSPECTION - RESIDENTIAL ¤574.75 08/02/2022
SW ENG RES REVIEW 200 ¤200.00 08/02/2022
SW ENG - FOUNDATION SURVEY ¤20.00 08/02/2022
SW ENG INSPECTION 80 ¤80.00 08/02/2022
SW ENG PRE APRON ¤30.00 08/02/2022
SURCHARGE - FS 468.631 ¤9.77 08/02/2022
SURCHARGE FS 533.721 ¤6.51 08/02/2022
IMPACT FEE TRANSPORTATION ¤1,764.00 08/02/2022
IMPACT FEE SCHOOL ¤3,600.00 08/02/2022
WATER -IRRIGATION INSPECTION ¤25.00 08/02/2022
SW ENG - REVIEW 20 ¤20.00 08/02/2022
3% TRANS IMPACT FEE CREDIT (¤52.92) 08/02/2022
SEWER CREDIT (¤850.00) 08/02/2022
SEWER INSPECTION ¤25.00 08/02/2022
SEWER CAPITAL FACILITY ¤4,939.76 08/02/2022
WATER CAPITAL FACILITY FEE ¤3,626.50 08/02/2022
3% PARKS IMPACT FEE CREDIT (¤43.65) 08/02/2022
SITE PLAN 30 ¤30.00 08/02/2022
SITE PLAN 30 ¤30.00 07/25/2022
SITE PLAN 30 (¤30.00) 07/25/2022
SEWER CAPITAL FACILITY ¤4,939.76 07/25/2022
WATER CAPITAL FACILITY FEE ¤3,626.50 07/25/2022
WATER CAPITAL FACILITY FEE (¤3,626.50) 07/25/2022
SEWER INSPECTION ¤25.00 07/25/2022
SEWER CAPITAL FACILITY (¤4,939.76) 07/25/2022
SEWER INSPECTION (¤25.00) 07/25/2022
SEWER CREDIT (¤850.00) 07/25/2022
SEWER CREDIT ¤850.00 07/25/2022
SW ENG RES REVIEW 200 (¤200.00) 07/25/2022
3% PARKS IMPACT FEE CREDIT (¤43.65) 07/25/2022
3% PARKS IMPACT FEE CREDIT ¤43.65 07/25/2022
IMPACT FEE TRANSPORTATION (¤1,764.00) 07/25/2022
IMPACT FEE TRANSPORTATION ¤1,764.00 07/25/2022
WATER -IRRIGATION INSPECTION ¤25.00 07/25/2022
WATER -IRRIGATION INSPECTION (¤25.00) 07/25/2022
SURCHARGE FS 533.721 ¤6.51 07/25/2022
SURCHARGE - FS 468.631 ¤9.77 07/25/2022
SURCHARGE - FS 468.631 (¤9.77) 07/25/2022
SW ENG - FOUNDATION SURVEY (¤20.00) 07/25/2022
SURCHARGE FS 533.721 (¤6.51) 07/25/2022
SW ENG PRE APRON ¤30.00 07/25/2022
SW ENG PRE APRON (¤30.00) 07/25/2022
SW ENG - FOUNDATION SURVEY ¤20.00 07/25/2022
SW ENG INSPECTION 80 ¤80.00 07/25/2022
SW ENG INSPECTION 80 (¤80.00) 07/25/2022
SW ENG RES REVIEW 200 ¤200.00 07/25/2022
3% TRANS IMPACT FEE CREDIT (¤52.92) 07/25/2022
3% TRANS IMPACT FEE CREDIT ¤52.92 07/25/2022
SW ENG - REVIEW 20 ¤20.00 07/25/2022
SW ENG - REVIEW 20 (¤20.00) 07/25/2022
INSPECTION - RESIDENTIAL ¤574.75 07/25/2022
PLAN REVIEW - RESIDENTIAL ¤163.02 07/25/2022
PLAN REVIEW - RESIDENTIAL (¤163.02) 07/25/2022
ADMINISTRATIVE RESIDENTIAL ¤30.00 07/25/2022
ADMINISTRATIVE RESIDENTIAL (¤30.00) 07/25/2022
WATER- TURN ON ¤25.00 07/25/2022
WATER- TURN ON (¤25.00) 07/25/2022
CONNECTION FEES ¤1,077.88 07/25/2022
CONNECTION FEES (¤1,077.88) 07/25/2022
3% FIRE IMPACT FEE CREDIT (¤11.66) 07/25/2022
IMPACT FEE FIRE ¤388.65 07/25/2022
IMPACT FEE FIRE (¤388.65) 07/25/2022
INSPECTION - RESIDENTIAL (¤574.75) 07/25/2022
IMPACT FEE PARKS ¤1,455.13 07/25/2022
IMPACT FEE SCHOOL ¤3,600.00 07/25/2022
IMPACT FEE SCHOOL (¤3,600.00) 07/25/2022
IMPACT FEE PARKS (¤1,455.13) 07/25/2022
3% FIRE IMPACT FEE CREDIT ¤11.66 07/25/2022
Fees Total Due: ¤0.00 Total Paid: ¤17,532.74