Permit #2022061189

Permit Details

Status: COED

Parcel Id: 07-11-31-7039-00050-0020
CONDITIONED SPACE: 1517 sqft
GARAGE: 394 sqft
Total Square Footage: 1911 sqft
Block: 00050
Subdivision: 2228 - SECTION 39-PINE GROVE
Job Phone: 475-276-4384
Location Address: 33 PENINSULA LN
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 07/14/2022
NOC: RECORDED
Applicant name: WADE GILMER JURNEY JR
Owner: NATIONAL HOME CORPORATION

Address

4850 TAMIAMI TRAIL NORTH

NAPLES, FL 34103

Lot: 0020
Contracted Stated Job Value: ¤207,853.00
Job Description: Single Family Residence
Type: CN

Contractor

NATIONAL HOME CORPORATION
Status Location Address Mailing Address State License Number Phone
INACTIVE

1080 HOLCOMB BRIDGE ROAD

,

BLDG 100 - 330

ROSWELL , GA 30076

CBC1257700 (Exp: 08/31/2026) 471-817-1259

Sub Contractors

DUSTIN L ESTEP
Status Location Address State License Number Phone Fax
ACTIVE

2041 N HIAWASSEE RD

APOPKA, FL 32703

CCC1330971 (Exp: 08/31/2026) 407-702-0206 352-988-6629
JASON PATRICK RIBOCK
Status Location Address State License Number Phone
INACTIVE

620 E PINE ST

, 0

ES12001313 (Exp: 08/31/2026) 407-625-0257
RUSSELL J CARTER
Status Location Address State License Number Phone Fax
ACTIVE

PO BOX 302

DELAND, FL 32721

CFC1425938 (Exp: 08/31/2026) 386-736-4220 386-736-4219
RANDALL SCOTT ROSENFELD
Status Location Address State License Number Phone
ACTIVE

234 N WHITNEY ST

PALM COAST, FL 32084

CAC1816641 (Exp: 08/31/2026) 904-599-0082

Inspection History

Type Request Date Result Inspector
BLD - BUILDING FINAL 02/27/2024 FINAL APPROVED KSANDOE
Note: 2/22/2024 - PREVIOUS INSPECTION NOTES 2/22/24: Cancelled by Applicant via text at @ 11:22. 2/21/2024 - PREVIOUS INSPECTION NOTES 2/21/24: Previously listed item 4 remains unresolved. 2/15/2024 - PREVIOUS INSPECTION NOTES 2/15/24: 1). A/C condenser pad needs to be leveled as required. M1305.1.4.1 Ground clearance. Equipment and appliances supported from the ground shall be level and firmly supported on a concrete slab or other approved material extending not less than 3 inches (76 mm) above the adjoining ground. Such support shall be in accordance with the manufacturer’s installation instructions. Appliances suspended from the floor shall have a clearance of not less than 6 inches (152 mm) from the ground. 2). Exterior temporary light cover needs to be weatherproof per NEC - 406.6 / 406.9(2E) 3). Water heater pan drain pipe needs to be protected from damage on the exterior. (left side yard area) P2603.2.1 4). Off ridge vents are not secured along the front flange as required by Manufacturer & FBC-R806.4 & R903.1.
BLD - BUILDING FINAL 02/22/2024 CANCELLED BY APPLICANT RSIMS
Note: 2/22/24: Cancelled by Applicant via text at @ 11:22. 2/21/2024 - PREVIOUS INSPECTION NOTES 2/21/24: Previously listed item 4 remains unresolved. 2/15/2024 - PREVIOUS INSPECTION NOTES 2/15/24: 1). A/C condenser pad needs to be leveled as required. M1305.1.4.1 Ground clearance. Equipment and appliances supported from the ground shall be level and firmly supported on a concrete slab or other approved material extending not less than 3 inches (76 mm) above the adjoining ground. Such support shall be in accordance with the manufacturer’s installation instructions. Appliances suspended from the floor shall have a clearance of not less than 6 inches (152 mm) from the ground. 2). Exterior temporary light cover needs to be weatherproof per NEC - 406.6 / 406.9(2E) 3). Water heater pan drain pipe needs to be protected from damage on the exterior. (left side yard area) P2603.2.1 4). Off ridge vents are not secured along the front flange as required by Manufacturer & FBC-R806.4 & R903.1.
BLD - BUILDING FINAL 02/21/2024 Disapproved -FEE REQUIRED RSIMS
Note: 2/21/24: Previously listed item 4 remains unresolved. 2/15/2024 - PREVIOUS INSPECTION NOTES 2/15/24: 1). A/C condenser pad needs to be leveled as required. M1305.1.4.1 Ground clearance. Equipment and appliances supported from the ground shall be level and firmly supported on a concrete slab or other approved material extending not less than 3 inches (76 mm) above the adjoining ground. Such support shall be in accordance with the manufacturer’s installation instructions. Appliances suspended from the floor shall have a clearance of not less than 6 inches (152 mm) from the ground. 2). Exterior temporary light cover needs to be weatherproof per NEC - 406.6 / 406.9(2E) 3). Water heater pan drain pipe needs to be protected from damage on the exterior. (left side yard area) P2603.2.1 4). Off ridge vents are not secured along the front flange as required by Manufacturer & FBC-R806.4 & R903.1.
BLD - BUILDING FINAL 02/15/2024 Disapproved - NO FEE RSIMS
Note: 2/15/24: 1). A/C condenser pad needs to be leveled as required. M1305.1.4.1 Ground clearance. Equipment and appliances supported from the ground shall be level and firmly supported on a concrete slab or other approved material extending not less than 3 inches (76 mm) above the adjoining ground. Such support shall be in accordance with the manufacturer’s installation instructions. Appliances suspended from the floor shall have a clearance of not less than 6 inches (152 mm) from the ground. 2). Exterior temporary light cover needs to be weatherproof per NEC - 406.6 / 406.9(2E) 3). Water heater pan drain pipe needs to be protected from damage on the exterior. (left side yard area) P2603.2.1 4). Off ridge vents are not secured along the front flange as required by Manufacturer & FBC-R806.4 & R903.1.
U -UTILITY RESIDENTIAL FINAL 02/12/2024 FINAL APPROVED LFITZGERALD
ROW FIELD SURVEY /GRADING CERTIFICATION 02/09/2024 APPROVED PFLANAGAN
Note: At the time of the inspection all minimum city requirements were met. It is the builders responsibiliy to ensure that nothing changes after this Inspection is approved. -------------------------------------------------------------------------------------------- 9/22/2023 - PREVIOUS INSPECTION NOTES 09/22/23 UPON WALKING THE PROPERTY A COUPLE OF ISSUES NEED TO BE ADDRESSED. THE RIGHT SIDE PROPERTY LINE THE HUMP NEEDS TO BE REMOVED AND A COMMON SWALE ATTAINED. Common Swale required when possible Sec 300.03 C1c Sec 300.03 C1c When grading against a developable vacant lot a 'Common Swale' (meaning the drainage conveyance is on the property line) is required. SWALE NEEDS TO MATCH GRADE ON BOTH PROPERTY LINE TO ALLOW POSITIVE FLOW. SPOKE TO CM ADN WENT OVER WHAT NEEDS TO BE ACCOMPLISHED. WILL MAKE CORRECTIONS.
ROW - STORMWATER FINAL 02/09/2024 APPROVED PFLANAGAN
Note: At the time of the inspection all minimum city requirements were met. It is the builders responsibiliy to ensure that nothing changes after this Inspection is approved.
ROW- PROJECT STATUS 02/09/2024 APPROVED PFLANAGAN
Note: MEET CM ON SITE FOR GRADE
ROW - FINAL APRON (AFTER POUR) 02/09/2024 APPROVED PFLANAGAN
Note: At the time of the inspection all minimum city requirements were met. It is the builders responsibiliy to ensure that nothing changes after this Inspection is approved.
ELECTRIC TEMP POLE 02/09/2024 CANCELLED BY INSPECTOR RMARTIN
Note: Inspector Notes from Inspection 2190 Emailed FPL @ 0817. Release Power
ROW- FINAL SURVEY/GRADING CERTIFICATION 09/22/2023 APPROVED FSLADISH
Note: 9/21/2023 - PREVIOUS INSPECTION NOTES 09/21/23 NOTHING HAS CHANGED, YOU HAVE RESUBMITTED THE SAME SURVEY AS PREVIOUSLY WITH NO W SWALE ELEVATION SHOTS ON BOTH SIDE PROPERTY LINES AS REQUESTED AND CONFIRMED BY YOUR SURVEYOR THAT THESE WOULD BE PROVIDED, RECORDED AND SURVEY RESUBMITTED FOR REVIEW. 09/21/23 NOTED AFTER MAKING A SITE VISIT I DETERMINED THAT YOUR SURVEY DOES NOT MATCH WHAT IS IN THE FIELD. YOUR SURVEY SHOWS A COMMON SWALE ON BOTH SIDES. NEITHER HAVE A COMMON SWALE. WE CALLED THE SURVEYOR AND ALERTED THEM TO THIS DISCREPENCY AND WERE TOLD THAT SOMEONE WOULD GO OUT AND RESHOOT THE W SWALES. THE RIGHT SIDE WILL STILL NEED TO BE A COMMON SWALE, BUT WE STILL NEED THE SWALE ELEVATION SHOTS. NOT GOING TO FEE YOU TODAY. ________________________________________________________________________________________________________________________. 9/20/2023 - PREVIOUS INSPECTION NOTES 09/20/23 AFTER MAKING A SITE VISIT I DETERMINED THAT YOUR SURVEY DOES NOT MATCH WHAT IS IN THE FIELD. YOUR SUEVEY SHOWS A COMMON SWALE ON BOTH SIDES. NEITHER HAVE A COMMON SWALE. WE CALLED THE SURVEYOR AND ALERTED THEM TO THIS DISCREPENCY AND WERE TOLD THAT SOMEONE WOULD GO OUT AND RESHOOT THE W SWALES. THE RIGHT SIDE WILL STILL NEED TO BE A COMMON SWALE, BUT WE STILL NEED THE SWALE ELEVATION SHOTS. NOT GOING TO FEE YOU TODAY. 9/14/2023 - PREVIOUS INSPECTION NOTES 09/14/23 YOUR SWALE ELEVATION ON THE RIGHT SHOWS THE PROPERTY LINE 25.40 WHICH IS 4 TENTHS HIGHER THAN THE SHOT TO THE RIGHT OF IT INDICATING 25.00. THAT SHOWS UPHILL FLOW. ON THE LEFT SIDE COMING OUT OF THE DOWNSTREAM SIDE AT THE CULVERT YOU SHOW 24.7 GOING UPHILL TO 25.30 YOUR LAST SHOT AT PROPERTY LINE. THESE NUMBERS INDICATE THAT THE WATER WILL NOT HAVE POSITIVE FLOW. Swale must flow in the right direction Sec. 300.01.c1 Sec. 300.01 c1The tolerance on the final swale elevations, compared to the Swale Plan, is plus or minus a tenth of a foot and must demonstrate positive fall in the direction described in the swale plan.
ROW FIELD SURVEY /GRADING CERTIFICATION 09/22/2023 Disapproved - NO FEE FSLADISH
Note: 09/22/23 UPON WALKING THE PROPERTY A COUPLE OF ISSUES NEED TO BE ADDRESSED. THE RIGHT SIDE PROPERTY LINE THE HUMP NEEDS TO BE REMOVED AND A COMMON SWALE ATTAINED. Common Swale required when possible Sec 300.03 C1c Sec 300.03 C1c When grading against a developable vacant lot a 'Common Swale' (meaning the drainage conveyance is on the property line) is required. SWALE NEEDS TO MATCH GRADE ON BOTH PROPERTY LINE TO ALLOW POSITIVE FLOW. SPOKE TO CM ADN WENT OVER WHAT NEEDS TO BE ACCOMPLISHED. WILL MAKE CORRECTIONS.
ROW- FINAL SURVEY/GRADING CERTIFICATION 09/21/2023 Disapproved - NO FEE FSLADISH
Note: 09/21/23 NOTHING HAS CHANGED, YOU HAVE RESUBMITTED THE SAME SURVEY AS PREVIOUSLY WITH NO W SWALE ELEVATION SHOTS ON BOTH SIDE PROPERTY LINES AS REQUESTED AND CONFIRMED BY YOUR SURVEYOR THAT THESE WOULD BE PROVIDED, RECORDED AND SURVEY RESUBMITTED FOR REVIEW. 09/21/23 NOTED AFTER MAKING A SITE VISIT I DETERMINED THAT YOUR SURVEY DOES NOT MATCH WHAT IS IN THE FIELD. YOUR SURVEY SHOWS A COMMON SWALE ON BOTH SIDES. NEITHER HAVE A COMMON SWALE. WE CALLED THE SURVEYOR AND ALERTED THEM TO THIS DISCREPENCY AND WERE TOLD THAT SOMEONE WOULD GO OUT AND RESHOOT THE W SWALES. THE RIGHT SIDE WILL STILL NEED TO BE A COMMON SWALE, BUT WE STILL NEED THE SWALE ELEVATION SHOTS. NOT GOING TO FEE YOU TODAY. ________________________________________________________________________________________________________________________. 9/20/2023 - PREVIOUS INSPECTION NOTES 09/20/23 AFTER MAKING A SITE VISIT I DETERMINED THAT YOUR SURVEY DOES NOT MATCH WHAT IS IN THE FIELD. YOUR SUEVEY SHOWS A COMMON SWALE ON BOTH SIDES. NEITHER HAVE A COMMON SWALE. WE CALLED THE SURVEYOR AND ALERTED THEM TO THIS DISCREPENCY AND WERE TOLD THAT SOMEONE WOULD GO OUT AND RESHOOT THE W SWALES. THE RIGHT SIDE WILL STILL NEED TO BE A COMMON SWALE, BUT WE STILL NEED THE SWALE ELEVATION SHOTS. NOT GOING TO FEE YOU TODAY. 9/14/2023 - PREVIOUS INSPECTION NOTES 09/14/23 YOUR SWALE ELEVATION ON THE RIGHT SHOWS THE PROPERTY LINE 25.40 WHICH IS 4 TENTHS HIGHER THAN THE SHOT TO THE RIGHT OF IT INDICATING 25.00. THAT SHOWS UPHILL FLOW. ON THE LEFT SIDE COMING OUT OF THE DOWNSTREAM SIDE AT THE CULVERT YOU SHOW 24.7 GOING UPHILL TO 25.30 YOUR LAST SHOT AT PROPERTY LINE. THESE NUMBERS INDICATE THAT THE WATER WILL NOT HAVE POSITIVE FLOW. Swale must flow in the right direction Sec. 300.01.c1 Sec. 300.01 c1The tolerance on the final swale elevations, compared to the Swale Plan, is plus or minus a tenth of a foot and must demonstrate positive fall in the direction described in the swale plan.
ROW- FINAL SURVEY/GRADING CERTIFICATION 09/20/2023 Disapproved - NO FEE FSLADISH
Note: 09/20/23 AFTER MAKING A SITE VISIT I DETERMINED THAT YOUR SURVEY DOES NOT MATCH WHAT IS IN THE FIELD. YOUR SURVEY SHOWS A COMMON SWALE ON BOTH SIDES. NEITHER HAVE A COMMON SWALE. WE CALLED THE SURVEYOR AND ALERTED THEM TO THIS DISCREPENCY AND WERE TOLD THAT SOMEONE WOULD GO OUT AND RESHOOT THE W SWALES. THE RIGHT SIDE WILL STILL NEED TO BE A COMMON SWALE, BUT WE STILL NEED THE SWALE ELEVATION SHOTS. NOT GOING TO FEE YOU TODAY. 9/14/2023 - PREVIOUS INSPECTION NOTES 09/14/23 YOUR SWALE ELEVATION ON THE RIGHT SHOWS THE PROPERTY LINE 25.40 WHICH IS 4 TENTHS HIGHER THAN THE SHOT TO THE RIGHT OF IT INDICATING 25.00. THAT SHOWS UPHILL FLOW. ON THE LEFT SIDE COMING OUT OF THE DOWNSTREAM SIDE AT THE CULVERT YOU SHOW 24.7 GOING UPHILL TO 25.30 YOUR LAST SHOT AT PROPERTY LINE. THESE NUMBERS INDICATE THAT THE WATER WILL NOT HAVE POSITIVE FLOW. Swale must flow in the right direction Sec. 300.01.c1 Sec. 300.01 c1The tolerance on the final swale elevations, compared to the Swale Plan, is plus or minus a tenth of a foot and must demonstrate positive fall in the direction described in the swale plan.
ROW- FINAL SURVEY/GRADING CERTIFICATION 09/14/2023 Disapproved - NO FEE FSLADISH
Note: 09/14/23 YOUR SWALE ELEVATION ON THE RIGHT SHOWS THE PROPERTY LINE 25.40 WHICH IS 4 TENTHS HIGHER THAN THE SHOT TO THE RIGHT OF IT INDICATING 25.00. THAT SHOWS UPHILL FLOW. ON THE LEFT SIDE COMING OUT OF THE DOWNSTREAM SIDE AT THE CULVERT YOU SHOW 24.7 GOING UPHILL TO 25.30 YOUR LAST SHOT AT PROPERTY LINE. THESE NUMBERS INDICATE THAT THE WATER WILL NOT HAVE POSITIVE FLOW. Swale must flow in the right direction Sec. 300.01.c1 Sec. 300.01 c1The tolerance on the final swale elevations, compared to the Swale Plan, is plus or minus a tenth of a foot and must demonstrate positive fall in the direction described in the swale plan.
ELECTRIC - EARLY POWER 07/12/2023 APPROVED - AS NOTED KSANDOE
Note: Emailed FPL @ 0817. Release Power
GRAVITY SEWER TEST 07/12/2023 APPROVED MGIBSON
U - SEWER TIE IN 07/11/2023 APPROVED - AS NOTED MGIBSON
Note: THIS WAS A VIRTUAL INSPECTION, C/M NEEDS TO SCHEDUAL GRAVITY SEWER FOR 7/12/23
U-CROSS CONNECTION 07/11/2023 APPROVED - AS NOTED LFITZGERALD
Note: no irrigation-no cross connection
ROW- PRE-APRON (PRE-POUR) 05/16/2023 APPROVED FSLADISH
Note: 05/16/23 LOOKED GOOD AT TIME OF INSPECTION. READY TO POUR. AT THE TIME OF THE INSPECTION CULVERT PIPE IS GOOD IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD DOUBLE CHECK CULVERT ELEVATIONS BEFORE POURING. MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL
INSULATION 05/16/2023 APPROVED KSANDOE
Note: 5/2/2023 - PREVIOUS INSPECTION NOTES Submit revised electrical detail for 200a service Inspector Notes from Inspection 2420 Submit revised electrical detail for 200a service 3/22/2023 - PREVIOUS INSPECTION NOTES Overhead service wire has been corrected to match 200A breaker. Cannot connect 150A service wire from main panel to sub panel. Building plans still reflect 150A service. 3/16/2023 - PREVIOUS INSPECTION NOTES Breaker and service wire still need to be addressed 3/10/2023 - PREVIOUS INSPECTION NOTES No change from previous inspection notes. Walk your jobs before scheduling inspections 3/6/2023 - PREVIOUS INSPECTION NOTES No mechanical installed Plans call for 150a service. 200a in panel. Wiring for overhead service must be sunlight resistant
INSULATION 05/02/2023 Disapproved -FEE REQUIRED KSANDOE
Note: Submit revised electrical detail for 200a service Inspector Notes from Inspection 2420 Submit revised electrical detail for 200a service 3/22/2023 - PREVIOUS INSPECTION NOTES Overhead service wire has been corrected to match 200A breaker. Cannot connect 150A service wire from main panel to sub panel. Building plans still reflect 150A service. 3/16/2023 - PREVIOUS INSPECTION NOTES Breaker and service wire still need to be addressed 3/10/2023 - PREVIOUS INSPECTION NOTES No change from previous inspection notes. Walk your jobs before scheduling inspections 3/6/2023 - PREVIOUS INSPECTION NOTES No mechanical installed Plans call for 150a service. 200a in panel. Wiring for overhead service must be sunlight resistant
ELECTRIC TEMP POLE 04/27/2023 Disapproved -FEE REQUIRED KSANDOE
Note: No temp pole installed. Not ready for inspection
ALL ROUGH 04/10/2023 APPROVED - AS NOTED KSANDOE
Note: Submit revised electrical detail for 200a service 3/22/2023 - PREVIOUS INSPECTION NOTES Overhead service wire has been corrected to match 200A breaker. Cannot connect 150A service wire from main panel to sub panel. Building plans still reflect 150A service. 3/16/2023 - PREVIOUS INSPECTION NOTES Breaker and service wire still need to be addressed 3/10/2023 - PREVIOUS INSPECTION NOTES No change from previous inspection notes. Walk your jobs before scheduling inspections 3/6/2023 - PREVIOUS INSPECTION NOTES No mechanical installed Plans call for 150a service. 200a in panel. Wiring for overhead service must be sunlight resistant
ALL ROUGH 03/22/2023 Disapproved -FEE REQUIRED KSANDOE
Note: Overhead service wire has been corrected to match 200A breaker. Cannot connect 150A service wire from main panel to sub panel. Building plans still reflect 150A service. 3/16/2023 - PREVIOUS INSPECTION NOTES Breaker and service wire still need to be addressed 3/10/2023 - PREVIOUS INSPECTION NOTES No change from previous inspection notes. Walk your jobs before scheduling inspections 3/6/2023 - PREVIOUS INSPECTION NOTES No mechanical installed Plans call for 150a service. 200a in panel. Wiring for overhead service must be sunlight resistant
ALL ROUGH 03/16/2023 Disapproved -FEE REQUIRED KSANDOE
Note: Breaker and service wire still need to be addressed 3/10/2023 - PREVIOUS INSPECTION NOTES No change from previous inspection notes. Walk your jobs before scheduling inspections 3/6/2023 - PREVIOUS INSPECTION NOTES No mechanical installed Plans call for 150a service. 200a in panel. Wiring for overhead service must be sunlight resistant
ALL ROUGH 03/10/2023 Disapproved -FEE REQUIRED KSANDOE
Note: No change from previous inspection notes. Walk your jobs before scheduling inspections 3/6/2023 - PREVIOUS INSPECTION NOTES No mechanical installed Plans call for 150a service. 200a in panel. Wiring for overhead service must be sunlight resistant
ALL ROUGH 03/06/2023 Disapproved - NO FEE KSANDOE
Note: No mechanical installed Plans call for 150a service. 200a in panel. Wiring for overhead service must be sunlight resistant
ROOF VALLEY & METAL 03/03/2023 APPROVED KSANDOE
Note: 2/21/2023 - PREVIOUS INSPECTION NOTES maximum spacing on nails at overlaps of 6 inches exceeded FBC-R Table 905.1.1 (2)
LATH/BRICK/ WATER BARRIER 02/27/2023 APPROVED KSANDOE
ROOF VALLEY & METAL 02/21/2023 Disapproved -FEE REQUIRED LMILLER
Note: maximum spacing on nails at overlaps of 6 inches exceeded FBC-R Table 905.1.1 (2)
WALL SHEATHING 02/10/2023 APPROVED TSTAUFFACHER
ROOF SHEATHING / BRACES/TIES/DOWN CELL 02/10/2023 APPROVED TSTAUFFACHER
FOUND SURVEY APPROVED (OFFICE) 02/09/2023 APPROVED TBAKER
TIE BEAM / LINTEL 01/30/2023 APPROVED KSANDOE
TIE BEAM / LINTEL 01/27/2023 CANCELLED BY APPLICANT WEB
MONOLITHIC SLAB 01/12/2023 APPROVED LMILLER
Note: 1/11/2023 - PREVIOUS INSPECTION NOTES Missing notice of termite treatment or intent Slab and footer areas need to be clear of roots and veg minimum 12" clean compacted earth. Root protruding into footer area in front of garage needs to be removed. 1-12-23 notes above resolved
MONOLITHIC SLAB 01/11/2023 Disapproved - NO FEE KSANDOE
Note: Missing notice of termite treatment or intent Slab and footer areas need to be clear of roots and veg minimum 12" clean compacted earth. Root protruding into footer area in front of garage needs to be removed.
PLUMBING 1ST ROUGH UNDERGROUND 01/05/2023 APPROVED MGIBSON
WATER METER INSTALLATION REQUEST 09/06/2022 APPROVED CSTONE

Review History

Department Status Date In Date Out
BADMIN INFORMATION 09/21/2023 09/21/2023
Note: Marked INFORMATION By: BARBIE BEMBRY - (386)986-3780 - BUILDINGDIVISION@PALMCOASTGOV.COM rename your files correctly.
BADMIN INFORMATION 06/22/2023 06/22/2023
Note: Marked INFORMATION By: SCOTT THOMAS - - STHOMAS@PALMCOASTGOV.COM NOC ILLEGIBLE
BADMIN INFORMATION 06/22/2023 06/22/2023
Note: Marked INFORMATION By: SCOTT THOMAS - - STHOMAS@PALMCOASTGOV.COM NOC ILLEGIBLE
BADMIN INFORMATION 06/16/2023 06/16/2023
Note: Marked INFORMATION By: SCOTT THOMAS - - STHOMAS@PALMCOASTGOV.COM NOC MISSING NOTARY AT BOTTOM
ENGIN1 COMPLETE 02/07/2023 02/09/2023
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
ZON COMPLETE 02/07/2023 02/08/2023
Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM
ZON COMPLETE 07/01/2022 07/01/2022
Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM
BLD COMPLETE 07/01/2022 07/05/2022
Note: Released By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM
BLD HOLD 06/21/2022 06/23/2022
Note: Held By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM All comments below per the 2020 Florida Building Code REVIEW COMMENTS: 1. Plans submitted are noted as a Master Plan. There is no Master Plan on file.
CUSVC COMPLETE 06/21/2022 06/23/2022
Note: Released By: HALEIGH HAND - -
ELEC COMPLETE 06/21/2022 06/21/2022
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
ENGIN1 COMPLETE 06/21/2022 06/21/2022
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
LOCATE COMPLETE 06/21/2022 06/24/2022
Note: Released By: CANDACE STONE - - CSTONE@PALMCOASTGOV.COM
MECH COMPLETE 06/21/2022 06/21/2022
Note: Released By: CHRIS PISCITELLI - (386)986-3782 - CPISCITELLI@PALMCOASTGOV.COM
SW1 COMPLETE 06/21/2022 06/28/2022
Note: Released By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM
ZON HOLD 06/21/2022 06/22/2022
Note: Held By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM Please provide width of walkway on site plan/survey One additional 7 gallon shrub required around AC Plantings must wrap both corners of house Need four shrubs along the left side the ones by driveway do not count
SWALE COMPLETE 06/21/2022 09/19/2022
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
REINSPECTION RESIDENTIAL ¤40.00 02/26/2024
SW ENG REINSPECTION 20 ¤20.00 02/14/2024
REINSPECTION RESIDENTIAL ¤40.00 09/25/2023
REINSPECTION RESIDENTIAL ¤40.00 09/25/2023
REINSPECTION RESIDENTIAL ¤40.00 04/13/2023
REINSPECTION RESIDENTIAL ¤40.00 04/13/2023
REINSPECTION RESIDENTIAL ¤40.00 04/13/2023
REINSPECTION RESIDENTIAL ¤40.00 04/13/2023
CONTRACTOR CHANGE ¤40.00 04/13/2023
CONTRACTOR CHANGE ¤20.00 04/13/2023
3% FIRE IMPACT FEE CREDIT (¤11.66) 07/14/2022
IMPACT FEE FIRE ¤388.65 07/14/2022
IMPACT FEE PARKS ¤1,455.13 07/14/2022
IMPACT FEE SCHOOL ¤3,600.00 07/14/2022
IMPACT FEE TRANSPORTATION ¤1,764.00 07/14/2022
WATER -IRRIGATION INSPECTION ¤25.00 07/14/2022
3% PARKS IMPACT FEE CREDIT (¤43.65) 07/14/2022
SURCHARGE FS 533.721 ¤6.48 07/14/2022
SURCHARGE - FS 468.631 ¤9.72 07/14/2022
SW ENG - FOUNDATION SURVEY ¤20.00 07/14/2022
SW ENG INSPECTION 80 ¤80.00 07/14/2022
SW ENG PRE APRON ¤30.00 07/14/2022
WATER- TURN ON ¤25.00 07/14/2022
ADMINISTRATIVE RESIDENTIAL ¤30.00 07/14/2022
INSPECTION - RESIDENTIAL ¤572.00 07/14/2022
PLAN REVIEW - RESIDENTIAL ¤162.24 07/14/2022
CONNECTION FEES ¤1,077.88 07/14/2022
SW ENG - REVIEW 20 ¤20.00 07/14/2022
SW ENG RES REVIEW 200 ¤200.00 07/14/2022
3% TRANS IMPACT FEE CREDIT (¤52.92) 07/14/2022
SEWER CREDIT (¤2,465.75) 07/14/2022
SEWER INSPECTION ¤25.00 07/14/2022
SEWER CAPITAL FACILITY ¤4,939.76 07/14/2022
WATER CAPITAL FACILITY FEE ¤3,626.50 07/14/2022
SITE PLAN 30 ¤30.00 07/14/2022
Fees Total Due: ¤0.00 Total Paid: ¤15,873.38