Permit #2022061196
Permit Details
Status: FINAL
| Parcel Id: 07-11-31-7029-00680-0030 |
| OPENED PORCH (WITH ROOF) : 943 sqft |
| Total Square Footage: 943 sqft |
| Block: 00680 |
| Subdivision: 2209 - SECTION 29-ROYAL PALMS |
| Job Phone: 386-264-4546 |
| Location Address: 85 RYMSHAW DR |
| Type: PO - POOL |
| Issue Date: 06/22/2022 |
| NOC: RECORDED |
| Applicant name: HENRY CURTIS CUSHING |
| Owner: RICHARD THEODORE C & CRYSTAL H&W |
|
Address 85 RYMSHAW DRIVE PALM COAST, FL 32164 |
| Lot: 0030 |
| Contracted Stated Job Value: ¤40,000.00 |
| Job Description: POOL & SPA REF # 2021031764 |
| Type: CN |
| Original Permit #: 2021031764 |
Contractor
HENRY CURTIS CUSHING
| Status | Location Address | State License Number | Fax |
| INACTIVE |
3625 WILLOW AVENUE DELAND, FL 32720 |
CPC1457061 (Exp: 08/31/2024) | 386-269-4908 |
Sub Contractors
JEFFREY ADAM MCGREGOR
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
1312 YORKTOWN STREET DELAND , FL 32724 |
EC13005662 (Exp: 08/31/2026) | 386-736-7475 | 386-785-1503 |
Inspection History
| Type | Request Date | Result | Inspector |
| POOL FINAL | 08/04/2022 | FINAL APPROVED | TSTAUFFACHER |
| Note: THIS IS A REINSPECTION Left side screen lania door did not close. Part of the barrier. Test guage on pump not installed. Unable to check TDH Pool alarm did not sound off. Spa alarm did not sound off. The doggie door installed in the screen lania, which is acting as the pool barrie will need to be removed. The barrier may not have any Gaps, openings ect. R-4501.17.1.2 | |||
| POOL FINAL | 07/07/2022 | Disapproved - NO FEE | JWALKER |
| Note: Left side screen lania door did not close. Part of the barrier. Test guage on pump not installed. Unable to check TDH Pool alarm did not sound off. Spa alarm did not sound off. The doggie door installed in the screen lania, which is acting as the pool barrie will need to be removed. The barrier may not have any Gaps, openings ect. R-4501.17.1.2 | |||
| U -UTILITY RESIDENTIAL FINAL | 07/01/2022 | FINAL APPROVED | LFITZGERALD |
| ROW - FINAL INSPECTION | 06/30/2022 | APPROVED | PFLANAGAN |
| Note: THIS IS A REINSPECTION a final survey needs to be submitted before a final inspection will be done and the swale needs to be repaired with sod before you schedule the final stormwater inspection | |||
| ROW FIELD SURVEY /GRADING CERTIFICATION | 06/30/2022 | APPROVED | PFLANAGAN |
| FINAL SURVEY (OFFICE USE ONLY) | 06/30/2022 | APPROVED | PFLANAGAN |
| Note: THIS IS A REINSPECTION NEED TO REGRADE BACK YARD FINAL SURVEY NUMBERS STATES THAT WATER IS NOT FLOWING LIKE SITE PLAN STATES WATER NEEDS TO FLOW BACK TO FRONT YARD. | |||
| FINAL SURVEY (OFFICE USE ONLY) | 01/28/2022 | Disapproved - NO FEE | PFLANAGAN |
| Note: NEED TO REGRADE BACK YARD FINAL SURVEY NUMBERS STATES THAT WATER IS NOT FLOWING LIKE SITE PLAN STATES WATER NEEDS TO FLOW BACK TO FRONT YARD. | |||
| ROW - FINAL INSPECTION | 10/07/2021 | CANCELLED BY APPLICANT | WEB |
| ROW - FINAL INSPECTION | 10/07/2021 | Disapproved -FEE REQUIRED | KRUTH |
| Note: a final survey needs to be submitted before a final inspection will be done and the swale needs to be repaired with sod before you schedule the final stormwater inspection | |||
| ELECTRIC AND ALARM | 09/28/2021 | APPROVED - AS NOTED | JMUNSON |
| Note: THIS IS A REINSPECTION THIS IS A REINSPECTION Pool alarm needs to be onsite for this inspection. 9/27/21 Need alarm for raised spa FRC 2020 45.17 9/28/21 Pool alarms on site test on final | |||
| ELECTRIC AND ALARM | 09/27/2021 | Disapproved - NO FEE | JMUNSON |
| Note: THIS IS A REINSPECTION Pool alarm needs to be onsite for this inspection. 9/27/21 Need alarm for raised spa FRC 2020 45.17 | |||
| ELECTRIC AND ALARM | 09/24/2021 | Disapproved - NO FEE | JMUNSON |
| Note: Pool alarm needs to be onsite for this inspection. | |||
| POOL DECK | 08/24/2021 | APPROVED | RMARTIN |
| Note: THIS IS A REINSPECTION Termite treat certifcate not posted or in permit package | |||
| POOL DECK | 08/23/2021 | Disapproved - NO FEE | TSTAUFFACHER |
| Note: Termite treat certifcate not posted or in permit package | |||
| STEEL AND GROUND | 05/14/2021 | APPROVED | MMESSER |
Review History
| Department | Status | Date In | Date Out |
| BADMIN | HOLD | 01/06/2022 | 01/06/2022 |
| Note: Held By: MARGA DEFREITAS - - MDEFREITAS@PALMCOASTGOV.COM we cannot submit your final survey your insurances is Inactive we need the Liability and the Workers Comp updates. | |||
| BADMIN | COMPLETE | 01/06/2022 | 01/06/2022 |
| Note: Released By: MARGA DEFREITAS - - MDEFREITAS@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 05/11/2021 | 05/12/2021 |
| Note: Released By: PATRICK BUCKLEY - (386)986-3786 - PBUCKLEY@PALMCOASTGOV.COM | |||
| BLD | HOLD | 05/04/2021 | 05/10/2021 |
| Note: Held By: FRED REODICA - (386)986-4734 - FREODICA@PALMCOASTGOV.COM Repeat comment: 1. Pool Plan: a. Whether pool cage is attached to house or not the pool cage should show: - Location of door(s). - Door swing (out from pool area). - Landings at doors (generally 36” x 36). - Indicate presence of latching device and height (54" above threshold) - Indicate presence of self-closing device. Note: The engineeered pool plan shall be re-submitted to delete Chapter 42 the 2020 FBC- Residential, 7th Edition as referenced code which is no longer used. | |||
| BLD | HOLD | 04/20/2021 | 04/27/2021 |
| Note: Held By: FRED REODICA - (386)986-4734 - FREODICA@PALMCOASTGOV.COM 1. Pool Plan: a. Whether pool cage is attached to house or not the pool cage should show: - Location of door(s). - Door swing (out from pool area). - Landings at doors (generally 36” x 36). - Indicate presence of latching device and height (54" above threshold) - Indicate presence of self-closing device. | |||
| ELEC | COMPLETE | 04/06/2021 | 04/06/2021 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| MECH | COMPLETE | 04/06/2021 | 04/07/2021 |
| Note: Released By: CHRIS PISCITELLI - - CPISCITELLI@PALMCOASTGOV.COM | |||
| BLD | HOLD | 04/06/2021 | 04/13/2021 |
| Note: Held By: FRED REODICA - (386)986-4734 - FREODICA@PALMCOASTGOV.COM Repeat comments: 1. Pool Plan: a. Whether pool cage is attached to house or not the pool cage should show: - Location of door(s). - Door swing (out from pool area). - Landings at doors (generally 36” x 36). - Indicate presence of latching device and height (54" above threshold) - Indicate presence of self-closing device. b. Alarms - Indicate location and type of pool alarms. - If water alarm show it in the pool location and indicate a ASTM F2208 alarm will be provided. - If window / door alarm show it at each window / door and indicate a UL 2017 alarm will be provided. - Provide manufacturer spec sheets for alarm(s) types and spec sheets indicate either ASTM F2208 or UL2017. 2. Engineered Pool Plan: a. Delete referenced Chapter 42 of 2020 FBC-Residential 7th Edition for Residential pools due to Code changes. 3. Permit cannot be released until plans for pool barrier are submitted as required per 2020 FBC- Residential 7th Ed. Sec. R4501.17. | |||
| BLD | HOLD | 03/29/2021 | 04/06/2021 |
| Note: Held By: FRED REODICA - (386)986-4734 - FReodica@ci.palm-coast.fl.us 1. Pool Plan: a. Whether pool cage is attached to house or not the pool cage should show: - Location of door(s). - Door swing (out from pool area). - Landings at doors (generally 36” x 36). - Indicate presence of latching device and height (54" above threshold) - Indicate presence of self-closing device. b. Alarms - Indicate location and type of pool alarms. - If water alarm show it in the pool location and indicate a ASTM F2208 alarm will be provided. - If window / door alarm show it at each window / door and indicate a UL 2017 alarm will be provided. - Provide manufacturer spec sheets for alarm(s) types and spec sheets indicate either ASTM F2208 or UL2017. 2. Engineered Pool Plan: a. Delete referenced Chapter 42 of 2020 FBC-Residential 7th Edition for Residential pools due to Code changes. 3. Permit cannot be released until plans for pool barrier are submitted as required per 2020 FBC- Residential 7th Ed. Sec. R4501.17. | |||
| ELEC | HOLD | 03/29/2021 | 03/29/2021 |
| Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM Need to reference the 2017 NEC not 2014 | |||
| MECH | HOLD | 03/29/2021 | 03/29/2021 |
| Note: Held By: CHRIS PISCITELLI - - CPISCITELLI@PALMCOASTGOV.COM Provide specs on pool heater. If gas pool heater, provide gas riser diagram or put note on plans that says " Gas By Others" | |||
| SW1 | COMPLETE | 03/29/2021 | 04/06/2021 |
| Note: Released By: CONRAD TROHA - (386)986-4767 - CTROHA@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 03/29/2021 | 03/31/2021 |
| Note: Released By: ALISHA MOBLEY - (386)986-4733 - AMOBLEY@PALMCOASTGOV.COM |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | 06/22/2022 |
| INSPECTION - GENERAL | ¤60.00 | 06/22/2022 |
| SURCHARGE FS 533.721 | ¤2.00 | 06/22/2022 |
| SURCHARGE - FS 468.631 | ¤2.00 | 06/22/2022 |
| SW ENG INSPECTION 40 | ¤40.00 | 06/22/2022 |
| SW ENG REINSPECTION 20 | ¤20.00 | 06/22/2022 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤154.00 |