I want to search for...

Permit #2022061239

Permit Details

Status: COED

Parcel Id: 07-11-31-7064-00380-0060
CONDITIONED SPACE: 1771 sqft
GARAGE: 473 sqft
OPENED PORCH (WITH ROOF) : 116 sqft
OPENED PORCH (WITH ROOF) : 263 sqft
Total Square Footage: 2623 sqft
Block: 00380
Subdivision: -
Job Phone: 386-237-1210
Location Address: 31 LLEWELLYN TR
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 06/28/2022
NOC: RECORDED
Applicant name: ANDREW POPOV
Owner: KOSTIANTYN KORNELIYOVYC TUDAN

Address

10 WHITE HAVEN LANE

PALM COAST, FL 32164

Lot: 0060
Contracted Stated Job Value: ¤250,000.00
Job Description: single family house
Type: CN

Contractor

SILVER BREEZE HOMES
Status Location Address State License Number Phone
ACTIVE

1 SEATHORN PATH UNIT A

PALM COAST, FL 32164

RR282812121 (Exp: 08/31/2027) 386-237-7700

Sub Contractors

GARY LLOYD SHEFFIELD
Status Location Address State License Number Phone
ACTIVE

48 EAGLE LAKES DRIVE

FLAGLER BEACH, FL 32136

CAC048127 (Exp: 08/31/2026) 386-597-3280
HEATH EDWARD SANFORD
Status Location Address State License Number Phone
ACTIVE

126 EAST END RD

SAN MATEO, FL 32187

CFC1429896 (Exp: 08/31/2026) 386-871-8823
MAXIM BUDNIK
Status Location Address State License Number Phone
ACTIVE

9788 HALSEY RD

JACKSONVILLE, FL 32246

EC13007415 (Exp: 08/31/2026) 904-509-7306
OLEG BELINSKIY
Status Location Address State License Number Phone
ACTIVE

19 PINE CIRCLE DRIVE19

PALM COAST, FL 32167

CCC1325974 (Exp: 08/31/2026) 386-263-7906

Inspection History

Type Request Date Result Inspector
BLD - BUILDING FINAL 08/08/2023 FINAL APPROVED RMARTIN
Note: 4/19/23: Check sliding glass door for matching/correct FBA # since this door was not fully installed at All Rough or Insulation (Noted at Insulation - Do not remove the FPA No. sticker until this inspection is approved). Also check soffit area for tight seal at vertical wall valleys since the wall flashing was not installed per manufacturer's requirements.
ROW - STORMWATER FINAL 07/24/2023 APPROVED PFLANAGAN
Note: At the time of the inspection all minimum city requirements were met. It is the builders responsibiliy to ensure that nothing changes after this Inspection is approved. ------------------------------------------------------------------------------------- 7/21/2023 - PREVIOUS INSPECTION NOTES 1) NEED TO CLEAN ALL DIRT OUT OF CULVERT PIPE 2) NEED TO CUT SOD OFF ALL FENCES 4" NO SOD CAN BE ON FENCES
U -UTILITY RESIDENTIAL FINAL 07/21/2023 FINAL APPROVED JHARDING
ROW - STORMWATER FINAL 07/21/2023 Disapproved -FEE REQUIRED PFLANAGAN
Note: 1) NEED TO CLEAN ALL DIRT OUT OF CULVERT PIPE 2) NEED TO CUT SOD OFF ALL FENCES 4" NO SOD CAN BE ON FENCES
ROW - FINAL APRON (AFTER POUR) 07/20/2023 APPROVED PFLANAGAN
Note: At the time of the inspection all minimum city requirements were met. It is the builders responsibiliy to ensure that nothing changes after this Inspection is approved.
ROW- FINAL SURVEY/GRADING CERTIFICATION 07/20/2023 APPROVED PFLANAGAN
Note: At the time of the inspection all minimum city requirements were met. It is the builders responsibiliy to ensure that nothing changes after this Inspection is approved.
ROW FIELD SURVEY /GRADING CERTIFICATION 07/20/2023 APPROVED PFLANAGAN
Note: At the time of the inspection all minimum city requirements were met. It is the builders responsibiliy to ensure that nothing changes after this Inspection is approved.
ELECTRIC - EARLY POWER 06/16/2023 APPROVED RSIMS
Note: 6/16/23: FPL emailed to release power.
ROW- PRE-APRON (PRE-POUR) 06/13/2023 APPROVED PFLANAGAN
Note: IT'S YOUR RESPONSIBILITY TO CHECK THE CULVERT PIPE ELEVATION BEFORE POURING CONCRETE. ALL CONCRETE NEEDS TO BE 3000PSI WITH FIBER OR WITH METAL MESH IN CONCRETE TO BE UP TO CITY'S STANDARTS.
U - SEWER TIE IN 05/18/2023 APPROVED MGIBSON
U-CROSS CONNECTION 05/18/2023 APPROVED DHANEY
GRAVITY SEWER TEST 05/18/2023 APPROVED MGIBSON
PEP TANK INSTALLATION REQUEST 05/10/2023 APPROVED CSTONE
Note: 4/11/2023 3:03:38 PM- PREVIOUS INSPECTION NOTES 4/11/2023 Exterior needs to be completed.
LATH/BRICK/ WATER BARRIER 04/25/2023 APPROVED RSIMS
INSULATION 04/21/2023 APPROVED BTAYLOR
Note: 4/19/2023 - PREVIOUS INSPECTION NOTES 4/19/23: Notes from All Rough remain unresolved. Moved door Inspection to building final. (do not remove FPA sticker until Building Final is approved). 1). Firestop at top plate of dryer exhaust is incomplete. 2).Missing firestop at Horizontal wire runs over 10ft. per FBC 302.11 Required Locations. ( section: 1.2. Horizontally at intervals not exceeding 10 feet (3048 mm)). Marked with FS on studs where required. 3). Left side back bedroom wall - missing firestop at top plate penetration. (Marked with FS on stud & floor below area). 4). Left bathroom - pack out wall is missing firestop at top plate as required. (FBC 302.11) 5). Missing cardboard baffels at left & right side ceiling level change and at front & back porch/entry/soffit areas as required. 4/10/23: Check noted at Insulation Inspection. Must be complete by Insulation. 1). SGD installation is incomplete. 2). UFER ground needs to be fully protected from CMU into Meter Panel box.
INSULATION 04/19/2023 Disapproved -FEE REQUIRED RSIMS
Note: 4/19/23: Notes from All Rough remain unresolved. Moved door Inspection to building final. (do not remove FPA sticker until Building Final is approved). 1). Firestop at top plate of dryer exhaust is incomplete. 2).Missing firestop at Horizontal wire runs over 10ft. per FBC 302.11 Required Locations. ( section: 1.2. Horizontally at intervals not exceeding 10 feet (3048 mm)). Marked with FS on studs where required. 3). Left side back bedroom wall - missing firestop at top plate penetration. (Marked with FS on stud & floor below area). 4). Left bathroom - pack out wall is missing firestop at top plate as required. (FBC 302.11) 5). Missing cardboard baffels at left & right side ceiling level change and at front & back porch/entry/soffit areas as required. 4/10/23: Check noted at Insulation Inspection. Must be complete by Insulation. 1). SGD installation is incomplete. 2). UFER ground needs to be fully protected from CMU into Meter Panel box.
PEP TANK INSTALLATION REQUEST 04/11/2023 Disapproved - NO FEE TSCHWEERS
Note: 4/11/2023 Exterior needs to be completed.
ALL ROUGH 04/10/2023 APPROVED - AS NOTED RSIMS
Note: 4/10/23: Check noted at Insulation Inspection. Must be complete by Insulation. 1). SGD installation is incomplete. 2). UFER ground needs to be fully protected from CMU into Meter Panel box.
WALL SHEATHING 04/10/2023 APPROVED RSIMS
ELECTRIC TEMP POLE 03/31/2023 APPROVED RSIMS
Note: 3/31/23: FPL emailed at @ 11:30
FRAMING 02/27/2023 CANCELLED BY APPLICANT WEB
Note: This inspection added due to incomplete interior framing during the Roof sheathing/ Braces/Ties/ Down Cell inspection.
ROOF SHEATHING / BRACES/TIES/DOWN CELL 02/24/2023 APPROVED BTAYLOR
Note: ***** Roof Sheathing (only) was bump checked during Inspection 2467 Roof Valley Metal - Approved 2/3/2023 - PREVIOUS INSPECTION NOTES 2/3/23: No changes! Still working on interior framing. Framing contractor was yelling and cursing at me. 2/2/2023 - PREVIOUS INSPECTION NOTES 2/2/23: INSPECTION STOPPED! INCOMPLETE INSPECTION! Not ready. 1). Most of the interior framing has been dismantled. 2). Load bearing walls are not built per plan detail. (ex. 12ft high) 3). Garage wall was not kept back 1/2" as required on plan. 4). On the load bearing walls the plan calls for SP2s at top and bottom of each stud but H2.5As were used in numerous locations. Need to replace with correct ones or an engineer's revision needs to be submitted to and approved by the City. 5). Garage door buck is not installed at this time.
ROOF VALLEY & METAL 02/24/2023 APPROVED BTAYLOR
Note: 2/23/2023 - PREVIOUS INSPECTION NOTES 2/23/23: Met with Builder to discuss what needs to be done as they were confused about needed changes. 2/13/2023 - PREVIOUS INSPECTION NOTES 2/13/23: Roof Valley Metal cannot be approved before approved roof sheathing so (although I am not required to do it) I bump checked the roof sheathing at this inspection.- Approved (Roof Sheathing only). 1). Vertical wall flashing (5" x 5") is installed incorrectly and not completely sealed along the wall. 2). Underlayment at all ridges is run vertically. Underlayment must be run horizontally across the roof plane & overlapped as required. 3). Underlayment nailing pattern does not meet Manufacturer's or Florida Building Code requirements. 905.1.1.1(5) - Synthetic underlayment shall be attached to a nailable deck with corrosion-resistant fasteners with a maximum fastener spacing, measured hoizontally and vertically of 12 inches (305 mm) O.C. between side laps and one row at the end and side laps fastened at 6 inches (152 mm) O.C. maximum. 4). Need revision submitted to & approved by the City for the different underlayment used then what was originally submitted. Roofing worksheet calls for self adhering underlayment byt synthetic barricade underlayment was installed.
ROOF VALLEY & METAL 02/23/2023 Disapproved - NO FEE RSIMS
Note: 2/23/23: Met with Builder to discuss what needs to be done as they were confused about needed changes. 2/13/2023 - PREVIOUS INSPECTION NOTES 2/13/23: Roof Valley Metal cannot be approved before approved roof sheathing so (although I am not required to do it) I bump checked the roof sheathing at this inspection.- Approved (Roof Sheathing only). 1). Vertical wall flashing (5" x 5") is installed incorrectly and not completely sealed along the wall. 2). Underlayment at all ridges is run vertically. Underlayment must be run horizontally across the roof plane & overlapped as required. 3). Underlayment nailing pattern does not meet Manufacturer's or Florida Building Code requirements. 905.1.1.1(5) - Synthetic underlayment shall be attached to a nailable deck with corrosion-resistant fasteners with a maximum fastener spacing, measured hoizontally and vertically of 12 inches (305 mm) O.C. between side laps and one row at the end and side laps fastened at 6 inches (152 mm) O.C. maximum. 4). Need revision submitted to & approved by the City for the different underlayment used then what was originally submitted. Roofing worksheet calls for self adhering underlayment byt synthetic barricade underlayment was installed.
ROOF VALLEY & METAL 02/13/2023 Disapproved -FEE REQUIRED RSIMS
Note: 2/13/23: Roof Valley Metal cannot be approved before approved roof sheathing so (although I am not required to do it) I bump checked the roof sheathing at this inspection.- Approved (Roof Sheathing only). 1). Vertical wall flashing (5" x 5") is installed incorrectly and not completely sealed along the wall. 2). Underlayment at all ridges is run vertically. Underlayment must be run horizontally across the roof plane & overlapped as required. 3). Underlayment nailing pattern does not meet Manufacturer's or Florida Building Code requirements. 905.1.1.1(5) - Synthetic underlayment shall be attached to a nailable deck with corrosion-resistant fasteners with a maximum fastener spacing, measured hoizontally and vertically of 12 inches (305 mm) O.C. between side laps and one row at the end and side laps fastened at 6 inches (152 mm) O.C. maximum. 4). Need revision submitted to & approved by the City for the different underlayment used than what was originally submitted. Roofing worksheet calls for self adhering underlayment byt synthetic barricade underlayment was installed.
ROOF SHEATHING / BRACES/TIES/DOWN CELL 02/03/2023 Disapproved -FEE REQUIRED RSIMS
Note: 2/3/23: No changes! Still working on interior framing. Framing contractor was yelling and cursing at me. Added framing inspection to permit. 2/2/2023 - PREVIOUS INSPECTION NOTES 2/2/23: INSPECTION STOPPED! INCOMPLETE INSPECTION! Not ready. 1). Most of the interior framing has been dismantled. 2). Load bearing walls are not built per plan detail. (ex. 12ft high) 3). Garage wall was not kept back 1/2" as required on plan. 4). On the load bearing walls the plan calls for SP2s at top and bottom of each stud but H2.5As were used in numerous locations. Need to replace with correct ones or an engineer's revision needs to be submitted to and approved by the City. 5). Garage door buck is not installed at this time.
ROOF SHEATHING / BRACES/TIES/DOWN CELL 02/02/2023 Disapproved -FEE REQUIRED RSIMS
Note: 2/2/23: INSPECTION STOPPED! INCOMPLETE INSPECTION! Not ready. 1). Most of the interior framing has been dismanted. 2). Load bearing walls are not built per plan detail. (ex. 12ft high) 3). Garage wall was not kept back 1/2" as required on plan. 4). On the load bearing walls the plan calls for SP2s at top and bottom of each stud but H2.5As were used in numerous locations. Need to replace with correct ones or an engineer's revision needs to be submitted to and approved by the City. 5). Garage door buck is not installed at this time.
TIE BEAM / LINTEL 11/09/2022 APPROVED BTAYLOR
FOUND SURVEY APPROVED (OFFICE) 10/21/2022 APPROVED TBAKER
MONOLITHIC SLAB 09/27/2022 APPROVED BTAYLOR
PLUMBING 1ST ROUGH UNDERGROUND 08/17/2022 APPROVED MGIBSON
WATER METER INSTALLATION REQUEST 07/18/2022 APPROVED TCHURCHILL

Review History

Department Status Date In Date Out
BLD COMPLETE 02/16/2023 02/21/2023
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
BLD HOLD 02/15/2023 02/16/2023
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Provide FL. Product approval number from 2020 code cycle. Fl-10124 R26 is from 2017
BLD COMPLETE 02/10/2023 02/15/2023
Note: Released By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM
ENGIN1 COMPLETE 10/21/2022 10/21/2022
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
ZON COMPLETE 10/21/2022 10/21/2022
Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM
BLD COMPLETE 08/15/2022 08/16/2022
Note: Released By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM
ENGIN1 COMPLETE 07/22/2022 07/22/2022
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
SW1 COMPLETE 07/22/2022 07/27/2022
Note: Released By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM
ZON COMPLETE 07/22/2022 07/22/2022
Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM
ZON COMPLETE 06/28/2022 06/28/2022
Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM
BLD COMPLETE 06/21/2022 06/23/2022
Note: Released By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM
CUSVC COMPLETE 06/21/2022 06/23/2022
Note: Released By: HALEIGH HAND - -
ELEC COMPLETE 06/21/2022 06/21/2022
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
ENGIN1 COMPLETE 06/21/2022 06/21/2022
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
LOCATE COMPLETE 06/21/2022 06/24/2022
Note: Released By: CANDACE STONE - - CSTONE@PALMCOASTGOV.COM
MECH COMPLETE 06/21/2022 06/21/2022
Note: Released By: CHRIS PISCITELLI - (386)986-3782 - CPISCITELLI@PALMCOASTGOV.COM
SW1 COMPLETE 06/21/2022 06/28/2022
Note: Released By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM
ZON HOLD 06/21/2022 06/23/2022
Note: Held By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM Site plan: Front walkway missing on site plan. Please include dimensions and material. Site plan and landscape dont match the drive and entrance are different in both plans Landscape plan: please provide sod and iirigation if required by LDC. Elevation: Banding is required on all windows and doors facing public Right of Way.
SWALE COMPLETE 06/21/2022 09/20/2022
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
PLAN REVIEW - REVISION ¤32.50 07/28/2023
PLAN REVIEW - REVISION ¤32.50 07/28/2023
PLAN REVIEW - REVISION ¤32.50 07/28/2023
REINSPECTION RESIDENTIAL ¤40.00 07/28/2023
REINSPECTION RESIDENTIAL ¤40.00 07/28/2023
REINSPECTION RESIDENTIAL ¤40.00 07/28/2023
REINSPECTION RESIDENTIAL ¤40.00 07/28/2023
SW ENG REINSPECTION 20 ¤20.00 07/28/2023
SW ENG - REVIEW 20 ¤20.00 06/28/2022
SW ENG RES REVIEW 200 ¤200.00 06/28/2022
3% TRANS IMPACT FEE CREDIT (¤52.92) 06/28/2022
SEWER CREDIT (¤1,390.00) 06/28/2022
SEWER INSPECTION ¤25.00 06/28/2022
SEWER CAPITAL FACILITY ¤4,939.76 06/28/2022
WATER CREDIT (¤1,733.75) 06/28/2022
WATER CAPITAL FACILITY FEE ¤3,626.50 06/28/2022
SITE PLAN 30 ¤30.00 06/28/2022
WATER- TURN ON ¤25.00 06/28/2022
ADMINISTRATIVE RESIDENTIAL ¤30.00 06/28/2022
INSPECTION - RESIDENTIAL ¤687.50 06/28/2022
PLAN REVIEW - RESIDENTIAL ¤195.00 06/28/2022
CONNECTION FEES ¤1,077.88 06/28/2022
3% FIRE IMPACT FEE CREDIT (¤11.66) 06/28/2022
IMPACT FEE FIRE ¤388.65 06/28/2022
IMPACT FEE PARKS ¤1,455.13 06/28/2022
IMPACT FEE SCHOOL ¤3,600.00 06/28/2022
IMPACT FEE TRANSPORTATION ¤1,764.00 06/28/2022
WATER -IRRIGATION INSPECTION ¤25.00 06/28/2022
3% PARKS IMPACT FEE CREDIT (¤43.65) 06/28/2022
SURCHARGE FS 533.721 ¤7.67 06/28/2022
SURCHARGE - FS 468.631 ¤11.50 06/28/2022
SW ENG - FOUNDATION SURVEY ¤20.00 06/28/2022
SW ENG INSPECTION 80 ¤80.00 06/28/2022
SW ENG PRE APRON ¤30.00 06/28/2022
Fees Total Due: ¤0.00 Total Paid: ¤15,284.11