I want to search for...

Permit #2022061254

Permit Details

Status: COED

Parcel Id: 07-11-31-7023-00400-0070
CONDITIONED SPACE: 2031 sqft
GARAGE: 748 sqft
SCREEN PORCH (SOLID ROOF) : 268 sqft
OPENED PORCH (WITH ROOF) : 140 sqft
Total Square Footage: 3187 sqft
Block: 00400
Subdivision: 2191 - SECTION 23-WYNNFIELD
Job Phone: 386-283-7499
Location Address: 22 WHITE HURST LN
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 07/07/2022
NOC: RECORDED
Applicant name: WILLIAM ROBERT BARRICK
Owner: JMR III LLC

Address

PO BOX 9

CISSNA PARK, IL 60924

Lot: 0070
Contracted Stated Job Value: ¤272,600.00
Job Description: single family residence
Type: CN

Contractor

RBI ENTERPRISES INC
Status Location Address State License Number Phone
CANCEL

10 WHITTINGTON DR

PALM COAST, FL 32164

RB29003845 (Exp: 08/31/2025) 386-585-4097

Sub Contractors

WILLIAM ROBERT BARRICK
Status Location Address State License Number Phone
CANCEL

21 CEDARWOOD CT

PALM COAST, FL 32137

RC29027799 (Exp: 08/31/2023) 229-375-9123
DAVID SCOTT MORRIS
Status Location Address State License Number Phone
INACTIVE

63 LEIDEL DR

PALM COAST, FL 32137

ER13015750 (Exp: 08/31/2026) 386-569-7262
GARY LLOYD SHEFFIELD
Status Location Address State License Number Phone
ACTIVE

PO BOX 912

PALM COAST, FL 32164

CAC1820539 (Exp: 08/31/2026) 386-264-0550
JONATHAN M PEARSON
Status Location Address State License Number Phone Fax
ACTIVE

209 N FORSYTH ST

BUNNELL, FL 32110

CFC1425941 (Exp: 08/31/2026) 386-597-0944 386-437-4996

Inspection History

Type Request Date Result Inspector
BLD - BUILDING FINAL 06/05/2023 FINAL APPROVED RMARTIN
Note: 6/2/2023 - PREVIOUS INSPECTION NOTES 6/2/23: 1). Romex wire to range outlet needs to be fully protected from damage per NEC 300.4 2). Garage door opener outlets are not GFCI protected per NEC 210.11 3). AHU breaker is too big. 4). Energy Calcs do not match installed units. Need revision submitted to & approved by the City.
BLD - BUILDING FINAL 06/02/2023 Disapproved -FEE REQUIRED RSIMS
Note: 6/2/23: 1). Romex wire to range outlet needs to be fully protected from damage per NEC 300.4 2). Garage door opener outlets are not GFCI protected per NEC 210.11 3). AHU breaker is too big. 4). Energy Calcs do not match installed units. Need revision submitted to & approved by the City.
ROW - FINAL APRON (AFTER POUR) 06/02/2023 APPROVED FSLADISH
Note: 06/02/23 PIPE IS GOOD. LOOKED GOOD AT TIME OF INSPECTION. ____________________________________________________________________________________________________________________ Inspector Notes from Inspection 9465 06/01/23 YOU WILL NEED TO REMOXE PLANTS AND MULCH FROM WHITE LINED AREA. YOU ARE NOT ALLOWED TO HAVE ANY LANDSCAPING WITHIN THE DRAINAGE CONVEYANCE. WILL NEED TO REMOVE IT AND LAY SOD THERE. ____________________________________________________________________________________________________________________ Inspector Notes from Inspection 9463 06/01/23 CORRECTIONS TO SURVEY MADE. FLOW HAS BEEN CORRECTED TO POSITIVE DRAINAGE. _____________________________________________________________________________________________________________________ 5/31/2023 - PREVIOUS INSPECTION NOTES 05/31/23 NEED TO CHECK YOUR LEFT SIDE CULVERT PIPE ELEVATIONS. SURVEY SHOWS IT FLOWING THE WRONG WAY BY 3 TENTHS. CULVERT PIPE MUST FLOW IN THE DIRECTION INDICATED WITHIN THE SWALE PLAN DIAGRAM WITHIN THE 1 TENTH TOLERANCE ALLOWED. PLEASE SEE PHOTO FOR REFERENCE.
ROW - STORMWATER FINAL 06/02/2023 FINAL APPROVED FSLADISH
Note: 06/02/23 CORRECTIONS MADE. LOOKED GOOD AT TIME OF INSPECTION. Inspector Notes from Inspection 9465 06/01/23 YOU WILL NEED TO REMOXE PLANTS AND MULCH FROM WHITE LINED AREA. YOU ARE NOT ALLOWED TO HAVE ANY LANDSCAPING WITHIN THE DRAINAGE CONVEYANCE. WILL NEED TO REMOVE IT AND LAY SOD THERE. ____________________________________________________________________________________________________________________ Inspector Notes from Inspection 9463 06/01/23 CORRECTIONS TO SURVEY MADE. FLOW HAS BEEN CORRECTED TO POSITIVE DRAINAGE. _____________________________________________________________________________________________________________________ 5/31/2023 - PREVIOUS INSPECTION NOTES 05/31/23 NEED TO CHECK YOUR LEFT SIDE CULVERT PIPE ELEVATIONS. SURVEY SHOWS IT FLOWING THE WRONG WAY BY 3 TENTHS. CULVERT PIPE MUST FLOW IN THE DIRECTION INDICATED WITHIN THE SWALE PLAN DIAGRAM WITHIN THE 1 TENTH TOLERANCE ALLOWED. PLEASE SEE PHOTO FOR REFERENCE.
U -UTILITY RESIDENTIAL FINAL 06/02/2023 FINAL APPROVED LFITZGERALD
ROW- FINAL SURVEY/GRADING CERTIFICATION 06/01/2023 APPROVED - AS NOTED FSLADISH
Note: 06/01/23 CORRECTIONS TO SURVEY MADE. FLOW HAS BEEN CORRECTED TO POSITIVE DRAINAGE. _____________________________________________________________________________________________________________________ 5/31/2023 - PREVIOUS INSPECTION NOTES 05/31/23 NEED TO CHECK YOUR LEFT SIDE CULVERT PIPE ELEVATIONS. SURVEY SHOWS IT FLOWING THE WRONG WAY BY 3 TENTHS. CULVERT PIPE MUST FLOW IN THE DIRECTION INDICATED WITHIN THE SWALE PLAN DIAGRAM WITHIN THE 1 TENTH TOLERANCE ALLOWED. PLEASE SEE PHOTO FOR REFERENCE.
ROW FIELD SURVEY /GRADING CERTIFICATION 06/01/2023 APPROVED - AS NOTED FSLADISH
Note: 06/01/23 YOU WILL NEED TO REMOXE PLANTS AND MULCH FROM WHITE LINED AREA. YOU ARE NOT ALLOWED TO HAVE ANY LANDSCAPING WITHIN THE DRAINAGE CONVEYANCE. WILL NEED TO REMOVE IT AND LAY SOD THERE. ____________________________________________________________________________________________________________________ Inspector Notes from Inspection 9463 06/01/23 CORRECTIONS TO SURVEY MADE. FLOW HAS BEEN CORRECTED TO POSITIVE DRAINAGE. _____________________________________________________________________________________________________________________ 5/31/2023 - PREVIOUS INSPECTION NOTES 05/31/23 NEED TO CHECK YOUR LEFT SIDE CULVERT PIPE ELEVATIONS. SURVEY SHOWS IT FLOWING THE WRONG WAY BY 3 TENTHS. CULVERT PIPE MUST FLOW IN THE DIRECTION INDICATED WITHIN THE SWALE PLAN DIAGRAM WITHIN THE 1 TENTH TOLERANCE ALLOWED. PLEASE SEE PHOTO FOR REFERENCE.
U-CROSS CONNECTION 06/01/2023 APPROVED - AS NOTED LFITZGERALD
Note: has potable irrigation with PVB installed-no cross connection
ROW- FINAL SURVEY/GRADING CERTIFICATION 05/31/2023 Disapproved - NO FEE FSLADISH
Note: 05/31/23 NEED TO CHECK YOUR LEFT SIDE CULVERT PIPE ELEVATIONS. SURVEY SHOWS IT FLOWING THE WRONG WAY BY 3 TENTHS. CULVERT PIPE MUST FLOW IN THE DIRECTION INDICATED WITHIN THE SWALE PLAN DIAGRAM WITHIN THE 1 TENTH TOLERANCE ALLOWED. PLEASE SEE PHOTO FOR REFERENCE.
ROW- PRE-APRON (PRE-POUR) 05/12/2023 APPROVED GBERTOLA
Note: AT THE TIME OF THE INSPECTION CULVERT PIPE IS GOOD IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD DOUBLE CHECK CULVERT ELEVATIONS BEFORE POURING. MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL
ELECTRIC - EARLY POWER 05/04/2023 APPROVED - AS NOTED MKRASKI
Note: 1. Ufer ground connnection must be accessible before final Emailed FPL @ 1:30 PM
GRAVITY SEWER TEST 04/18/2023 APPROVED MKRASKI
U - SEWER TIE IN 04/18/2023 APPROVED MKRASKI
PEP TANK INSTALLATION REQUEST 03/23/2023 APPROVED TSCHWEERS
INSULATION 03/16/2023 APPROVED MKRASKI
Note: 3/15/2023 - PREVIOUS INSPECTION NOTES 1. Address not visible from road per FBC R319.1, Stopped inspection
INSULATION 03/15/2023 Disapproved - NO FEE MKRASKI
Note: 1. Address not visible from road per FBC R319.1, Stopped inspection
LATH/BRICK/ WATER BARRIER 03/10/2023 APPROVED MKRASKI
ALL ROUGH 03/06/2023 APPROVED MKRASKI
ALL ROUGH 03/03/2023 Disapproved - NO FEE MKRASKI
Note: 1. Address not visible per FBC 319.1 2. Exhaust fan ducts need to be supported every 4' 3. Electrical nail plates at top 1x on exterior wall needs to cover wiring 1005 where it passes through wood 4. KItchen island power chase requires nail plates at both ends Stopped inspection
ALL ROUGH 03/02/2023 CANCELLED BY APPLICANT WEB
ROOF SHEATHING / BRACES/TIES/DOWN CELL 01/17/2023 APPROVED MKRASKI
ROOF VALLEY & METAL 01/12/2023 APPROVED MKRASKI
ROOF SHEATHING / BRACES/TIES/DOWN CELL 01/11/2023 Disapproved -FEE REQUIRED KSANDOE
Note: 1/11/23 Multiple trusses misxsing bracing. Marked on plans. Did not check previous notes 1/9/2023 - PREVIOUS INSPECTION NOTES 1. Door opening in load bearing walls not per detail marked on print 2. 3-1/2 x 5-1/4 PSL col. requires 2 HTS 20s 3. Truss T07 missing engineering 4. TRuss T35 (gable) missing engineering Stopped inspection, need to finish checking truss engineering
WALL SHEATHING 01/09/2023 APPROVED MKRASKI
ROOF SHEATHING / BRACES/TIES/DOWN CELL 01/09/2023 Disapproved - NO FEE MKRASKI
Note: 1. Door opening in load bearing walls not per detail marked on print 2. 3-1/2 x 5-1/4 PSL col. requires 2 HTS 20s 3. Truss T07 missing engineering 4. TRuss T35 (gable) missing engineering Stopped inspection, need to finish checking truss engineering
FOUND SURVEY APPROVED (OFFICE) 01/06/2023 APPROVED BBEMBRY
TIE BEAM / LINTEL 11/04/2022 APPROVED MKRASKI
TIE BEAM / LINTEL 11/03/2022 Disapproved - NO FEE MKRASKI
Note: No plans on site FBC 107.3.1
MONOLITHIC SLAB 10/26/2022 Disapproved - NO FEE MKRASKI
Note: Plans do not match slab, Interior footing, lani reveresed, stopped inspection
MONOLITHIC SLAB 10/26/2022 APPROVED MKRASKI
MONOLITHIC SLAB 10/24/2022 CANCELLED BY APPLICANT KSANDOE
PLUMBING 1ST ROUGH UNDERGROUND 10/19/2022 APPROVED MGIBSON
WATER METER INSTALLATION REQUEST 10/07/2022 APPROVED CSTONE

Review History

Department Status Date In Date Out
MECH COMPLETE 06/02/2023 06/02/2023
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
MECH COMPLETE 05/18/2023 05/19/2023
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
ZON COMPLETE 03/30/2023 03/30/2023
Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM Changed color of house to white
SW1 COMPLETE 03/16/2023 03/20/2023
Note: Released By: FRANK SLADISH - - FSLADISH@PALMCOASTGOV.COM
ENGIN1 COMPLETE 03/16/2023 03/16/2023
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
ZON COMPLETE 03/16/2023 03/16/2023
Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM All plans must match. Looks the back patio area shown on site plan is not the same as all other plans
BADMIN INFORMATION 03/13/2023 03/13/2023
Note: Marked INFORMATION By: LIBBY MUSGROVE - - LMUSGROVE@PALMCOASTGOV.COM file names do not match the document type need to rename
BADMIN INFORMATION 03/13/2023 03/13/2023
Note: Marked INFORMATION By: SCOTT THOMAS - - STHOMAS@PALMCOASTGOV.COM 1. SELECT 'SITE PLAN' AS DROP DOWN BOX CATEGORY 2. RENAME TO SITE PLAN.PDF
ENGIN1 HOLD 01/24/2023 01/24/2023
Note: Held By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM Wrong foundation survey submitted
ZON HOLD 01/24/2023 01/24/2023
Note: Held By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM Foundations survey is for another address.
BLD COMPLETE 01/13/2023 01/13/2023
Note: Released By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM
MECH COMPLETE 11/13/2022 11/15/2022
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
ENGIN1 COMPLETE 11/13/2022 11/14/2022
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
ZON COMPLETE 11/13/2022 11/14/2022
Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM
ELEC COMPLETE 11/03/2022 11/03/2022
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
MECH HOLD 11/03/2022 11/03/2022
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Provide duct layout signed by the AC contractor
BLD COMPLETE 10/03/2022 10/03/2022
Note: Released By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM
BLD COMPLETE 10/03/2022 10/04/2022
Note: Released By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM
ELEC HOLD 10/03/2022 10/04/2022
Note: Held By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM All comments below per the 2020 Florida Building Code REVIEW COMMENTS: 1. Provide GFI outlet in Bath #3
ZON COMPLETE 10/03/2022 10/03/2022
Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM
ENGIN1 COMPLETE 10/03/2022 10/04/2022
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
MECH HOLD 10/03/2022 10/04/2022
Note: Held By: CHRIS PISCITELLI - (386)986-3782 - CPISCITELLI@PALMCOASTGOV.COM Revise Energy Calcs
SW1 COMPLETE 10/03/2022 10/07/2022
Note: Released By: ROBERT GROSS - (386)986-4769 - RGROSS@PALMCOASTGOV.COM
ELEC COMPLETE 07/06/2022 07/06/2022
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
SWALE COMPLETE 06/22/2022 09/21/2022
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
BLD COMPLETE 06/21/2022 06/22/2022
Note: Released By: CHRIS PISCITELLI - (386)986-3782 - CPISCITELLI@PALMCOASTGOV.COM
CUSVC COMPLETE 06/21/2022 06/23/2022
Note: Released By: HALEIGH HAND - -
ELEC HOLD 06/21/2022 06/22/2022
Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM Need correct outlet spacing in bed 2. Switch wall. NEC 2017 210.52
ENGIN1 COMPLETE 06/21/2022 06/22/2022
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
LOCATE COMPLETE 06/21/2022 06/24/2022
Note: Released By: CANDACE STONE - - CSTONE@PALMCOASTGOV.COM
MECH COMPLETE 06/21/2022 06/22/2022
Note: Released By: CHRIS PISCITELLI - (386)986-3782 - CPISCITELLI@PALMCOASTGOV.COM
SW1 COMPLETE 06/21/2022 06/27/2022
Note: Released By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM
ZON COMPLETE 06/21/2022 06/24/2022
Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
PLAN REVIEW - REVISION ¤32.50 06/05/2023
REINSPECTION RESIDENTIAL ¤40.00 06/05/2023
REINSPECTION RESIDENTIAL ¤40.00 05/31/2023
PLAN REVIEW - REVISION ¤32.50 05/31/2023
PLAN REVIEW - REVISION ¤32.50 05/31/2023
PLAN REVIEW - REVISION ¤32.50 05/31/2023
PLAN REVIEW - REVISION ¤32.50 05/31/2023
PLAN REVIEW - REVISION ¤32.50 05/31/2023
WATER-METER ¤467.09 07/07/2022
WATER- TURN ON ¤25.00 07/07/2022
WATER- TURN ON ¤25.00 07/07/2022
ADMINISTRATIVE RESIDENTIAL ¤30.00 07/07/2022
INSPECTION - RESIDENTIAL ¤750.75 07/07/2022
PLAN REVIEW - RESIDENTIAL ¤212.94 07/07/2022
CONNECTION FEES ¤1,077.88 07/07/2022
3% FIRE IMPACT FEE CREDIT (¤11.66) 07/07/2022
IMPACT FEE FIRE ¤388.65 07/07/2022
IMPACT FEE PARKS ¤1,455.13 07/07/2022
IMPACT FEE SCHOOL ¤3,600.00 07/07/2022
IMPACT FEE TRANSPORTATION ¤1,764.00 07/07/2022
WATER -IRRIGATION INSPECTION ¤25.00 07/07/2022
WATER -IRRIGATION INSPECTION ¤25.00 07/07/2022
3% PARKS IMPACT FEE CREDIT (¤43.65) 07/07/2022
SURCHARGE FS 533.721 ¤8.32 07/07/2022
SURCHARGE - FS 468.631 ¤12.47 07/07/2022
SW ENG - FOUNDATION SURVEY ¤20.00 07/07/2022
SW ENG INSPECTION 80 ¤80.00 07/07/2022
SW ENG PRE APRON ¤30.00 07/07/2022
SW ENG - REVIEW 20 ¤20.00 07/07/2022
SW ENG RES REVIEW 200 ¤200.00 07/07/2022
3% TRANS IMPACT FEE CREDIT (¤52.92) 07/07/2022
SEWER CREDIT (¤1,146.71) 07/07/2022
SEWER INSPECTION ¤25.00 07/07/2022
SEWER CAPITAL FACILITY ¤4,939.76 07/07/2022
WATER CAPITAL FACILITY FEE ¤3,626.50 07/07/2022
SITE PLAN 30 ¤30.00 07/07/2022
Fees Total Due: ¤0.00 Total Paid: ¤17,858.55