I want to search for...

Permit #2022061358

Permit Details

Status: COED

Parcel Id: 07-11-31-7033-00150-0190
CONDITIONED SPACE: 1311 sqft
CONDITIONED SPACE: 1311 sqft
GARAGE: 499 sqft
GARAGE: 499 sqft
OPENED PORCH (WITH ROOF) : 58 sqft
OPENED PORCH (WITH ROOF) : 58 sqft
OPENED PORCH (WITH ROOF) : 158 sqft
OPENED PORCH (WITH ROOF) : 158 sqft
Total Square Footage: 4052 sqft
Block: 00150
Subdivision: 2184 - SECTION 33-ROYAL PALMS
Job Phone: 386-585-2654
Location Address: 17 REGIS LN
Type: DU - DUPLEX
Issue Date: 07/14/2022
NOC: RECORDED
Applicant name: DESIDERIO CARLOS CARREIRO
Owner: ANDRE RICK & AMY ANDRE

Address

470 LOFTUS STREET

NEW BEDFORD, MA 02746

Lot: 0190
Contracted Stated Job Value: ¤200,000.00
Job Description: DUPLEX

Contractor

RED LINE CONSTRUCTION CO
Status Location Address State License Number Phone
ACTIVE

6 COMMERCIAL CT

PALM COAST, FL 32137

CGC1527392 (Exp: 08/31/2026) 386-585-2654

Sub Contractors

GARY LLOYD SHEFFIELD
Status Location Address State License Number Phone
ACTIVE

48 EAGLE LAKES DRIVE

FLAGLER BEACH, FL 32136

CAC048127 (Exp: 08/31/2026) 386-597-3280
DESIDERIO CARLOS CARREIRO
Status Location Address State License Number Phone
ACTIVE

6 COMMERCIAL CT

PALM COAST, FL 32137

CGC1527392 (Exp: 08/31/2026) 386-585-2654
FERNANDO M FARIA
Status Location Address State License Number Phone
ACTIVE

23 FREELAND LANE

PALM COAST, FL 32137

RF11067823 (Exp: 08/31/2027) 386-569-4336
MAXIM BUDNIK
Status Location Address State License Number Phone
ACTIVE

9788 HALSEY RD

JACKSONVILLE, FL 32246

EC13007415 (Exp: 08/31/2026) 904-509-7306

Inspection History

Type Request Date Result Inspector
BLD - BUILDING FINAL 10/24/2023 FINAL APPROVED JWALKER
Note: New inspection due to canceled inspection 10/19/2023 - PREVIOUS INSPECTION NOTES 1. Missing vaccum breakers at the exterior hose bibs. 2. Rear porch outlet, and the front porch outlet at unit A are not GFI protected. 3. The Energy calculations for the AHU in Unit A do not match. 4. Toilet Bases both units need to be sealed to floor. 5. Missing water hammer at the dishwasher water supply pipes both units. 6. Smoke detectors are not communicating with one another. When one is alarm triggers all smoke are to sound an alarm. UNIT B 7. Outlet next to the water heater is not resetting. 8. Kitchen counter top 2nd out let from the sink has no power. Dining room area outlet no power. 9. Dishwasher outlet is required to be GFI protected. 10. No hot water at the kitchen sink. 11. Toilet not flushing, and low pressure at the shower.
BLD - BUILDING FINAL 10/23/2023 CANCELLED BY APPLICANT WEB
Note: 10/19/2023 - PREVIOUS INSPECTION NOTES 1. Missing vaccum breakers at the exterior hose bibs. 2. Rear porch outlet, and the front porch outlet at unit A are not GFI protected. 3. The Energy calculations for the AHU in Unit A do not match. 4. Toilet Bases both units need to be sealed to floor. 5. Missing water hammer at the dishwasher water supply pipes both units. 6. Smoke detectors are not communicating with one another. When one is alarm triggers all smoke are to sound an alarm. UNIT B 7. Outlet next to the water heater is not resetting. 8. Kitchen counter top 2nd out let from the sink has no power. Dining room area outlet no power. 9. Dishwasher outlet is required to be GFI protected. 10. No hot water at the kitchen sink. 11. Toilet not flushing, and low pressure at the shower.
BLD - BUILDING FINAL 10/19/2023 Disapproved -FEE REQUIRED JWALKER
Note: 1. Missing vaccum breakers at the exterior hose bibs. 2. Rear porch outlet, and the front porch outlet at unit A are not GFI protected. 3. The Energy calculations for the AHU in Unit A do not match. 4. Toilet Bases both units need to be sealed to floor. 5. Missing water hammer at the dishwasher water supply pipes both units. 6. Smoke detectors are not communicating with one another. When one is alarm triggers all smoke are to sound an alarm. UNIT B 7. Outlet next to the water heater is not resetting. 8. Kitchen counter top 2nd out let from the sink has no power. Dining room area outlet no power. 9. Dishwasher outlet is required to be GFI protected. 10. No hot water at the kitchen sink. 11. Toilet not flushing, and low pressure at the shower.
ROW - FINAL INSPECTION 10/19/2023 APPROVED PFLANAGAN
Note: At the time of the inspection all minimum city requirements were met. It is the builders responsibiliy to ensure that nothing changes after this Inspection is approved. ------------------------------------------------------------------------------ 10/18/2023 - PREVIOUS INSPECTION NOTES STILL NEED TOCLEAN ALL CONSTRUCTION DEBRIS AND TRASH FROM THE VACANT LOT ------------------------------------------------------------------------------- 10/16/2023 - PREVIOUS INSPECTION NOTES 1) NEED TO CLEAN ALL TRASH AND ALL CONSTRUCTION DEBRIS FROM THE VACANT LOT TO THE RIGHT OF YOURS ------------------------------------------------------------------------------- 10/12/2023 - PREVIOUS INSPECTION NOTES 1) NEED TO CLEAN ALL TRASH AND ALL CONSTRUCTION DEBRIS FROM THE VACANT LOT TO THE RIGHT OF YOURS AND ALL CONCRETE THAT IS ON THE DRIVEWAY PLEASE CLEAN ALL DIRT OUT OF CULVERTS AGAIN BEFORE CALLING FOR THE NEXT INSPECTION
ROW - FINAL INSPECTION 10/18/2023 Disapproved -FEE REQUIRED PFLANAGAN
Note: STILL NEED TOCLEAN ALL CONSTRUCTION DEBRIS AND TRASH FROM THE VACANT LOT ------------------------------------------------------------------------------- 10/16/2023 - PREVIOUS INSPECTION NOTES 1) NEED TO CLEAN ALL TRASH AND ALL CONSTRUCTION DEBRIS FROM THE VACANT LOT TO THE RIGHT OF YOURS ------------------------------------------------------------------------------- 10/12/2023 - PREVIOUS INSPECTION NOTES 1) NEED TO CLEAN ALL TRASH AND ALL CONSTRUCTION DEBRIS FROM THE VACANT LOT TO THE RIGHT OF YOURS AND ALL CONCRETE THAT IS ON THE DRIVEWAY PLEASE CLEAN ALL DIRT OUT OF CULVERTS AGAIN BEFORE CALLING FOR THE NEXT INSPECTION
ROW - FINAL INSPECTION 10/16/2023 Disapproved -FEE REQUIRED PFLANAGAN
Note: 1) NEED TO CLEAN ALL TRASH AND ALL CONSTRUCTION DEBRIS FROM THE VACANT LOT TO THE RIGHT OF YOURS ------------------------------------------------------------------------------- 10/12/2023 - PREVIOUS INSPECTION NOTES 1) NEED TO CLEAN ALL TRASH AND ALL CONSTRUCTION DEBRIS FROM THE VACANT LOT TO THE RIGHT OF YOURS AND ALL CONCRETE THAT IS ON THE DRIVEWAY PLEASE CLEAN ALL DIRT OUT OF CULVERTS AGAIN BEFORE CALLING FOR THE NEXT INSPECTION
ROW - FINAL INSPECTION 10/12/2023 Disapproved -FEE REQUIRED PFLANAGAN
Note: 1) NEED TO CLEAN ALL TRASH AND ALL CONSTRUCTION DEBRIS FROM THE VACANT LOT TO THE RIGHT OF YOURS AND ALL CONCRETE THAT IS ON THE DRIVEWAY PLEASE CLEAN ALL DIRT OUT OF CULVERTS AGAIN BEFORE CALLING FOR THE NEXT INSPECTION
U -UTILITY RESIDENTIAL FINAL 10/12/2023 FINAL APPROVED LFITZGERALD
Note: Inspector Notes from Inspection 9035 no irrigation-no cross connection
ROW - FINAL APRON (AFTER POUR) 10/11/2023 APPROVED PFLANAGAN
Note: At the time of the inspection all minimum city requirements were met. It is the builders responsibiliy to ensure that nothing changes after this Inspection is approved.
ROW FIELD SURVEY /GRADING CERTIFICATION 10/11/2023 APPROVED PFLANAGAN
Note: THE FIELD SHOWS NO SWALE ON THE LEFT SIDE OF HOUSE BUT THE 10' OFF SETS SAYS IT WILL NOT IMPACT THE ADJACENT LOT At the time of the inspection all minimum city requirements were met. It is the builders responsibiliy to ensure that nothing changes after this Inspection is approved. -------------------------------------------------------------------------------------- 10/10/2023 - PREVIOUS INSPECTION NOTES NEED TO CUT GRASS SO I CAN SEE GRADE OF THE LOT BETTER CODE 15-108 (d) Excessive growth of grass, weeds, or brush and other overgrowth means grass or weeds or brush, or bushes, or shrubs, or trees, or vines, or flowering plants and other living plant life that is allowed to grow in a wild and unkempt manner not in keeping with the neighborhood. ----------------------------------------------------------------------------------------------- 10/5/2023 - PREVIOUS INSPECTION NOTES THIS INSPECTION IS DONE AFTER THE FINAL SURVEY IS PASSED
ROW FIELD SURVEY /GRADING CERTIFICATION 10/10/2023 Disapproved - NO FEE PFLANAGAN
Note: NEED TO CUT GRASS SO I CAN SEE GRADE OF THE LOT BETTER CODE 15-108 (d) Excessive growth of grass, weeds, or brush and other overgrowth means grass or weeds or brush, or bushes, or shrubs, or trees, or vines, or flowering plants and other living plant life that is allowed to grow in a wild and unkempt manner not in keeping with the neighborhood. ----------------------------------------------------------------------------------------------- 10/5/2023 - PREVIOUS INSPECTION NOTES THIS INSPECTION IS DONE AFTER THE FINAL SURVEY IS PASSED
ROW- FINAL SURVEY/GRADING CERTIFICATION 10/10/2023 APPROVED PFLANAGAN
Note: At the time of the inspection all minimum city requirements were met. It is the builders responsibiliy to ensure that nothing changes after this Inspection is approved. -------------------------------------------------------------------- 10/6/2023 - PREVIOUS INSPECTION NOTES 10/5/2023 - PREVIOUS INSPECTION NOTES 1) THE SOD ELEVATIONS AGAINST THE HOUSE ALL NEED TO BE 4" BELOW FFE OF THE STRUCTURE 2) THE RIGHT CULVERT INVERT IS OUT OF TOLERANCE WITH THE SWALE PLAN DETAIL THAT WAS PROVIDED CULVERT NEEDS TO BE WITH IN A .10 +/-
ROW- FINAL SURVEY/GRADING CERTIFICATION 10/06/2023 CANCELLED BY APPLICANT PFLANAGAN
Note: 10/5/2023 - PREVIOUS INSPECTION NOTES 1) THE SOD ELEVATIONS AGAINST THE HOUSE ALL NEED TO BE 4" BELOW FFE OF THE STRUCTURE 2) THE RIGHT CULVERT INVERT IS OUT OF TOLERANCE WITH THE SWALE PLAN DETAIL THAT WAS PROVIDED CULVERT NEEDS TO BE WITH IN A .10 +/-
ROW- FINAL SURVEY/GRADING CERTIFICATION 10/05/2023 Disapproved - NO FEE PFLANAGAN
Note: 1) THE SOD ELEVATIONS AGAINST THE HOUSE ALL NEED TO BE 4" BELOW FFE OF THE STRUCTURE 2) THE RIGHT CULVERT INVERT IS OUT OF TOLERANCE WITH THE SWALE PLAN DETAIL THAT WAS PROVIDED CULVERT NEEDS TO BE WITH IN A .10 +/-
ROW FIELD SURVEY /GRADING CERTIFICATION 10/05/2023 Disapproved - NO FEE PFLANAGAN
Note: THIS INSPECTION IS DONE AFTER THE FINAL SURVEY IS PASSED
U-CROSS CONNECTION 10/05/2023 APPROVED - AS NOTED LFITZGERALD
Note: no irrigation-no cross connection
ROW- PRE-APRON (PRE-POUR) 08/28/2023 APPROVED PFLANAGAN
Note: IT'S YOUR RESPONSIBILITY TO CHECK THE CULVERT PIPE ELEVATIONS BEFORE POURING CONCRETE FOR DRIVEWAY. ALL CONCRETE MUST BE A MINIMUM OF 3000PSI WITH FIBER OR METAL MESH IN THE CONCRETE TO MEET CITY'S STANDARTS. At the time of the inspection all minimum city requirements were met. It is the builders responsibiliy to ensure that nothing changes after this Inspection is approved.
ELECTRIC - EARLY POWER 07/26/2023 APPROVED JWALKER
Note: 7/21/2023 - PREVIOUS INSPECTION NOTES Electrical riser does not match what is installed
ELECTRIC - EARLY POWER 07/21/2023 Disapproved - NO FEE MKRASKI
Note: Electrical riser does not match what is installed
FIREWALL FINAL 07/06/2023 Disapproved - NO FEE JWALKER
Note: Ceilings have been sheet rocked, blowin insulation has been installed, Unable to access the fire wall.
FIREWALL FINAL 07/06/2023 APPROVED - AS NOTED JWALKER
Note: 7/6/23 Meeting with contractor onsite. Contractor pushed back blowin insulation revealing fire resistant markings on the 5/8" sheet rock. 7/6/2023 - PREVIOUS INSPECTION NOTES Ceilings have been sheet rocked, blowin insulation has been installed, Unable to access the fire wall.
GRAVITY SEWER TEST 07/05/2023 APPROVED MGIBSON
Note: Inspector Notes from Inspection 2060 REMOVE ALL VEGITATION FROM SLAB BEFORE SLAB INPECTION
U - SEWER TIE IN 07/05/2023 APPROVED MGIBSON
PEP TANK INSTALLATION REQUEST 05/19/2023 APPROVED CSTONE
LATH/BRICK/ WATER BARRIER 05/11/2023 APPROVED RMARTIN
Note: 5/8/2023 - PREVIOUS INSPECTION NOTES 1. Front of the building at the lower part of the corners. Spray foam has been used to attach the corner beads. The foam will need to be removed as this will not allow for correct stucco depth. 2. Install wire mesh to fill the holes in the CMU wall at the electrical panel area. 3. Scrape foam at window areas to allow for correct stucco fill.
LATH/BRICK/ WATER BARRIER 05/08/2023 Disapproved - NO FEE JWALKER
Note: 1. Front of the building at the lower part of the corners. Spray foam has been used to attach the corner beads. The foam will need to be removed as this will not allow for correct stucco depth. 2. Install wire mesh to fill the holes in the CMU wall at the electrical panel area. 3. Scrape foam at window areas to allow for correct stucco fill.
INSULATION 05/05/2023 APPROVED JWALKER
ALL ROUGH 05/03/2023 APPROVED TSTAUFFACHER
Note: 4/28/2023 - PREVIOUS INSPECTION NOTES 1. The electrical riser installed is not matching the submitted and approved riser diagram on page 2 of 5 of the prints. please submitt a revision to the building department for the changes. 2. The resseced lights above the shower / tub areas are to marked suitable for wet locations. 3. Tub piping in unit B is leaking. 4. Unit A 5' head test is not holding water. 5. The boot flashing at the electrical mast is not the correct size and is not seal properly. 6. The windows and the sliding glass doors product approvals do not match the FL approved product numbers submitted to the building depart. Please submitt a revision to the building department for the changes.. Inspection stopped.
ALL ROUGH 04/28/2023 Disapproved - NO FEE JWALKER
Note: 1. The electrical riser installed is not matching the submitted and approved riser diagram on page 2 of 5 of the prints. please submitt a revision to the building department for the changes. 2. The resseced lights above the shower / tub areas are to marked suitable for wet locations. 3. Tub piping in unit B is leaking. 4. Unit A 5' head test is not holding water. 5. The boot flashing at the electrical mast is not the correct size and is not seal properly. 6. The windows and the sliding glass doors product approvals do not match the FL approved product numbers submitted to the building depart. Please submitt a revision to the building department for the changes.. Inspection stopped.
ALL ROUGH 04/26/2023 CANCELLED BY APPLICANT WEB
ALL ROUGH 04/26/2023 CANCELLED BY APPLICANT BTAYLOR
WALL SHEATHING 04/24/2023 APPROVED JWALKER
FIREWALL DRYWALL NAILING 04/04/2023 APPROVED JWALKER
Note: Inspector Notes from Inspection 2460 3/8/2023 The 1/2 drywall draft stop in the attic will need to have framing added to the truss to support the rock. The truss web members are further apart then the minimum 2' o.c. framing needed to support the drywall. 2/24/2023 - PREVIOUS INSPECTION NOTES Enigneering passed. Down cells passed. 1. Truss 13 unit a garage left CMU wall heta straps missing fasteners. 2. Bearing walls in separating the garage and living area have not been consturcted as per the details. 3. The Fire wall has not been constructed as per the details. Please construct the two areas listed above as per the prints or submitt a revision to the building department for any changes. Roof decking has missed nailing listed on the roof valley inspection
ROOF SHEATHING / BRACES/TIES/DOWN CELL 03/08/2023 APPROVED - AS NOTED JWALKER
Note: 3/8/2023 The 1/2 drywall draft stop in the attic will need to have framing added to the truss to support the rock. The truss web members are further apart then the minimum 2' o.c. framing needed to support the drywall. 2/24/2023 - PREVIOUS INSPECTION NOTES Enigneering passed. Down cells passed. 1. Truss 13 unit a garage left CMU wall heta straps missing fasteners. 2. Bearing walls in separating the garage and living area have not been consturcted as per the details. 3. The Fire wall has not been constructed as per the details. Please construct the two areas listed above as per the prints or submitt a revision to the building department for any changes. Roof decking has missed nailing listed on the roof valley inspection
ROOF VALLEY & METAL 02/27/2023 APPROVED KSANDOE
Note: 2/24/2023 - PREVIOUS INSPECTION NOTES Roof deck needs to be nailed down at Truss T04 rear porch area, Truss 15 unit A left side garage, and Unit A Above window at the bedroom near the garage.
ROOF VALLEY & METAL 02/24/2023 Disapproved - NO FEE JWALKER
Note: Roof deck needs to be nailed down at Truss T04 rear porch area, Truss 15 unit A left side garage, and Unit A Above window at the bedroom near the garage.
ROOF SHEATHING / BRACES/TIES/DOWN CELL 02/24/2023 Disapproved - NO FEE JWALKER
Note: Enigneering passed. Down cells passed. 1. Truss 13 unit a garage left CMU wall heta straps missing fasteners. 2. Bearing walls in separating the garage and living area have not been consturcted as per the details. 3. The Fire wall has not been constructed as per the details. Please construct the two areas listed above as per the prints or submitt a revision to the building department for any changes. Roof decking has missed nailing listed on the roof valley inspection
TIE BEAM / LINTEL 12/07/2022 APPROVED - AS NOTED JWALKER
Note: 11/29/2022 - PREVIOUS INSPECTION NOTES 1. Multiple missed dowels and down rods. 2. Multiple dowels that were drilled into place have not drilled the required minimum of 6" into the concrete and set in epoxy. 3. Where the walls step up the contractor dropped pieces of rebar into the down cells and tied to the dowels to give the appearance of a down rod. Down rods are to be continous from the top of the wall to the bottom of the wall where the down rod connects to the dowel. CHECK ALL. 4. Window opening on the left side wall has not been installed. Drawing have been highlighted. 12/7/22 The bath window listed above. Please submitt a revision to the building department for this change. Contractor is approved to pour down cells at risk revision is not accepted. Check for revison at roof brace inspection.
TIE BEAM / LINTEL 12/01/2022 CANCELLED BY APPLICANT JWALKER
Note: 11/29/2022 - PREVIOUS INSPECTION NOTES 1. Multiple missed dowels and down rods. 2. Multiple dowels that were drilled into place have not drilled the required minimum of 6" into the concrete and set in epoxy. 3. Where the walls step up the contractor dropped pieces of rebar into the down cells and tied to the dowels to give the appearance of a down rod. Down rods are to be continous from the top of the wall to the bottom of the wall where the down rod connects to the dowel. CHECK ALL. 4. Window opening on the left side wall has not been installed. Drawing have been highlighted.
TIE BEAM / LINTEL 11/29/2022 Disapproved -FEE REQUIRED JWALKER
Note: 1. Multiple missed dowels and down rods. 2. Multiple dowels that were drilled into place have not drilled the required minimum of 6" into the concrete and set in epoxy. 3. Where the walls step up the contractor dropped pieces of rebar into the down cells and tied to the dowels to give the appearance of a down rod. Down rods are to be continous from the top of the wall to the bottom of the wall where the down rod connects to the dowel. CHECK ALL. 4. Window opening on the left side wall has not been installed. Drawings have been Highlighted.
FOUND SURVEY APPROVED (OFFICE) 11/14/2022 APPROVED TBAKER
MONOLITHIC SLAB 10/25/2022 APPROVED JWALKER
Note: 10/24/2022 - PREVIOUS INSPECTION NOTES Remove roots from footings. Right side footing and front proch area. Marked the drawings. Slab needs to be tamped down due to overthrown soil during piping install.
MONOLITHIC SLAB 10/24/2022 Disapproved - NO FEE JWALKER
Note: Remove roots from footings. Right side footing and front proch area. Marked the drawings. Slab needs to be tamped down due to overthrown soil during piping install.
PLUMBING 1ST ROUGH UNDERGROUND 09/19/2022 APPROVED - AS NOTED MGIBSON
Note: REMOVE ALL VEGITATION FROM SLAB BEFORE SLAB INPECTION
WATER METER INSTALLATION REQUEST 09/09/2022 APPROVED CSTONE

Review History

Department Status Date In Date Out
MECH COMPLETE 10/05/2023 10/09/2023
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
MECH HOLD 09/29/2023 10/02/2023
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Energy Calcs need to be signed by the owner/ owner agent below the preparer per R103.1.1.2 FBC Energy Conservation 2020 7Th edition
BADMIN COMPLETE 09/29/2023 09/29/2023
Note: Released By: SCOTT THOMAS - (386)986-3780 - STHOMAS@PALMCOASTGOV.COM NOC EXPIRED. CAN NOT SCHEDULE FINAL SURVEY INSPECTION
ELEC COMPLETE 07/24/2023 07/25/2023
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
BLD COMPLETE 05/02/2023 05/03/2023
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
ELEC COMPLETE 05/02/2023 05/03/2023
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
BLD COMPLETE 03/06/2023 03/07/2023
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
BLD COMPLETE 12/20/2022 12/21/2022
Note: Released By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM
ENGIN1 COMPLETE 11/14/2022 11/14/2022
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
ZON COMPLETE 11/14/2022 11/14/2022
Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM
ZON COMPLETE 07/11/2022 07/11/2022
Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM
ENGIN1 COMPLETE 07/08/2022 07/12/2022
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
SW1 COMPLETE 07/08/2022 07/13/2022
Note: Released By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM
ZON HOLD 07/08/2022 07/08/2022
Note: Held By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM The minimum required front setback for duplex zoning is 25'. Please submit site plan that adheres to this minimum.
BADMIN INFORMATION 07/05/2022 07/05/2022
Note: Marked INFORMATION By: SCOTT THOMAS - - STHOMAS@PALMCOASTGOV.COM COMPLETE OWNER INFORMATION ON UTILITY APPLICATION RENAME TO UTILITY APPLICATION. REMOVE ADDRESS FROM FILE NAME
BADMIN INFORMATION 07/05/2022 07/05/2022
Note: Marked INFORMATION By: SCOTT THOMAS - - STHOMAS@PALMCOASTGOV.COM COMPLETE OWNER INFORMATION ON UTILITY APPLICATION
CUSVC COMPLETE 07/05/2022 07/07/2022
Note: Released By: CYNTHIA SCHWEERS - - CSCHWEERS@PALMCOASSTGOV.COM
SWALE COMPLETE 06/23/2022 09/21/2022
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
BLD COMPLETE 06/23/2022 06/24/2022
Note: Released By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM
CUSVC HOLD 06/23/2022 06/23/2022
Note: Held By: HALEIGH HAND - - Please upload a utility application.
ELEC COMPLETE 06/23/2022 06/23/2022
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
ENGIN1 COMPLETE 06/23/2022 06/23/2022
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
LOCATE COMPLETE 06/23/2022 06/29/2022
Note: Released By: CANDACE STONE - - CSTONE@PALMCOASTGOV.COM
MECH COMPLETE 06/23/2022 06/23/2022
Note: Released By: CHRIS PISCITELLI - (386)986-3782 - CPISCITELLI@PALMCOASTGOV.COM
SW1 COMPLETE 06/23/2022 06/27/2022
Note: Released By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM
ZON HOLD 06/23/2022 06/24/2022
Note: Held By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM Please provide walkway material and width on site plan/survey

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
PLAN REVIEW - REVISION ¤32.50 10/24/2023
PLAN REVIEW - REVISION ¤32.50 10/24/2023
REINSPECTION RESIDENTIAL ¤40.00 10/24/2023
REINSPECTION RESIDENTIAL ¤40.00 10/24/2023
CONTRACTOR CHANGE ¤40.00 10/24/2023
CONTRACTOR CHANGE ¤20.00 10/24/2023
CONTRACTOR CHANGE ¤20.00 10/24/2023
SW ENG REINSPECTION 20 ¤20.00 10/24/2023
SW ENG REINSPECTION 20 ¤20.00 10/24/2023
SW ENG REINSPECTION 20 ¤20.00 10/24/2023
SW ENG - REVIEW 20 ¤20.00 07/14/2022
SW ENG RES REVIEW 200 ¤200.00 07/14/2022
3% TRANS IMPACT FEE CREDIT (¤82.14) 07/14/2022
SEWER CREDIT (¤5,099.24) 07/14/2022
SEWER INSPECTION ¤25.00 07/14/2022
SEWER CAPITAL FACILITY ¤9,879.52 07/14/2022
WATER CREDIT (¤179.74) 07/14/2022
WATER CAPITAL FACILITY FEE ¤7,253.00 07/14/2022
SITE PLAN 30 ¤30.00 07/14/2022
3% FIRE IMPACT FEE CREDIT (¤23.32) 07/14/2022
IMPACT FEE FIRE ¤777.30 07/14/2022
IMPACT FEE PARKS ¤2,910.26 07/14/2022
IMPACT FEE SCHOOL ¤7,200.00 07/14/2022
IMPACT FEE TRANSPORTATION ¤2,738.00 07/14/2022
WATER -IRRIGATION INSPECTION ¤50.00 07/14/2022
3% PARKS IMPACT FEE CREDIT (¤87.31) 07/14/2022
SURCHARGE FS 533.721 ¤10.49 07/14/2022
SURCHARGE - FS 468.631 ¤15.73 07/14/2022
SW ENG - FOUNDATION SURVEY ¤20.00 07/14/2022
SW ENG INSPECTION 80 ¤80.00 07/14/2022
SW ENG PRE APRON ¤30.00 07/14/2022
CONNECTION FEES ¤2,155.76 07/14/2022
WATER- TURN ON ¤50.00 07/14/2022
ADMINISTRATIVE RESIDENTIAL ¤30.00 07/14/2022
INSPECTION - RESIDENTIAL ¤962.50 07/14/2022
PLAN REVIEW - RESIDENTIAL ¤273.00 07/14/2022
Fees Total Due: ¤0.00 Total Paid: ¤29,523.81