I want to search for...
Permit #2022061464
Permit Details
Status: FINAL
| Parcel Id: 41-11-31-0000-01010-0100 |
| Block: 01010 |
| Subdivision: - |
| Job Phone: 352-446-1241 |
| Location Address: 29 UTILITY DR |
| Type: TA - TELECOMMUNICATION TOWER ALTERATION |
| Issue Date: 11/02/2022 |
| NOC: RECORDED |
| Applicant name: STEVEN HUGH NICHOLS |
| Owner: OPM-USA INC %AMERICAN TOWER CORP |
|
Address PO BOX 723597 ATLANTA, GA 31139 |
| Lot: 0100 |
| Contracted Stated Job Value: ¤15,000.00 |
| Job Description: T-MOBILE - WIRELESS ANTENNA UPGRADE ON EXISTING CELLULAR TOWER |
| Type: CN |
| Original Permit #: 2021091391 |
Contractor
ERICSSON INC
| Status | Location Address | State License Number | Phone |
| INACTIVE |
6300 LEGACY DRIVE PLANO, TX 75024 |
CGC1518237 (Exp: 08/31/2024) | 352-446-1241 |
Sub Contractors
FRANK JOSEPH KISEL
| Status | Location Address | State License Number | Phone |
| ACTIVE |
6300 LEGACY DRIVE PLANO, TX 75024 |
EC13009490 (Exp: 08/31/2026) | 469-266-1818 |
Inspection History
| Type | Request Date | Result | Inspector |
| FINAL | 05/17/2023 | FINAL APPROVED | FWILLIS |
| ENGINEERS APPROVAL LETTER | 05/15/2023 | APPROVED | JMUNSON |
Review History
| Department | Status | Date In | Date Out |
| BLD | COMPLETE | 05/14/2023 | 05/15/2023 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| DSD | COMPLETE | 11/29/2021 | 11/29/2021 |
| Note: Released By: DAMARIS RAMIREZ - (386)986-3750 - DRAMIREZ@PALMCOASTGOV.COM | |||
| ITC | COMPLETE | 10/07/2021 | 12/01/2021 |
| Note: Released By: BARBIE BEMBRY - (386)986-3780 - BUILDINGDIVISION@PALMCOASTGOV.COM Waiting for third party review payment to begin review. From: Ben Evans <ben@cityscapegov.com> Sent: Tuesday, October 26, 2021 11:50 AM To: bjones@tepgroup.net; steve.nichols@ericsson.com Cc: Barbie Bembry <BBembry@palmcoastgov.com>; elizabeth@cityscapegov.com Subject: Proposed T-Mobile upgrade at 29 Utility Dr Palm Coast FL To Whom this may concern, I am the third-party engineer reviewing your application on behalf of T-Mobile to upgrade the above referenced wireless facility (T-Mobile #A2A0017A, ATC #2563). The application doesn’t include a structural analysis for the antenna sector mounts. The ANSI/TIA-222-H standards generally require analysis reports to be prepared for both the tower and the antenna supports when a carrier proposes equipment changes on a tower. If an antenna mount structural has been done, please email that report to us. If it has not been done, we ask that you either order the analysis, or provide a written explanation from the structural engineer (must be a registered PE) why a mount analysis is not necessary under the “H” standards. Please be aware that until a satisfactory response to this request is received, the application is considered incomplete. | |||
| BLD | COMPLETE | 09/30/2021 | 10/04/2021 |
| Note: Released By: PATRICK BUCKLEY - (386)986-3786 - PBUCKLEY@PALMCOASTGOV.COM | |||
| DSD | HOLD | 09/30/2021 | 10/05/2021 |
| Note: Held By: JACQUELINE GONZALEZ - (386)986-3751 - JGONZALEZ@PALMCOASTGOV.COM Awaiting payment to send to consultant for review. | |||
| ELEC | COMPLETE | 09/30/2021 | 10/04/2021 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| CONTRACTOR CHANGE | ¤20.00 | 11/10/2022 |
| SURCHARGE FS 533.721 | ¤2.00 | 11/02/2022 |
| SURCHARGE - FS 468.631 | ¤2.00 | 11/02/2022 |
| ADJUSTMENT 50% | (¤90.00) | 11/02/2022 |
| ADMINISTRATIVE - COMMERCIAL | ¤75.00 | 11/02/2022 |
| INSPECTION COMMERCIAL | ¤105.00 | 11/02/2022 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤114.00 |