I want to search for...
Permit #2022061674
Permit Details
Status: COED
| Parcel Id: 29-10-31-5540-00000-1530 |
| GARAGE: 759 sqft |
| OPENED PORCH (WITH ROOF) : 841 sqft |
| CONDITIONED SPACE: 3544 sqft |
| OPENED PORCH (WITH ROOF) : 60 sqft |
| Total Square Footage: 5204 sqft |
| Block: 00000 |
| Subdivision: 1005 - SANCTUARY SUBDIVISION |
| Job Phone: 386-315-4087 |
| Location Address: 35 OLD OAK DR S |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 08/09/2022 |
| NOC: RECORDED |
| Applicant name: BRIAN CHRISTOPHER MULLEN |
| Owner: DYER DIANE M |
|
Address 112 OAK STREET FLAGLER BEACH, FL 32136 |
| Lot: 1530 |
| Contracted Stated Job Value: ¤470,000.00 |
| Job Description: Single Family Residence |
| Type: CN |
Contractor
FIVE STAR ROOFING
| Status | Location Address | State License Number | Phone |
| INACTIVE |
PO BOX 351158 PALM COAST, FL |
CGC049971 (Exp: 08/31/2026) | 386-385-8504 |
Sub Contractors
DANIEL P HUCKS
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
400 N. U.S. 1 Ormond Beach, FL 32174 |
CAC029376 (Exp: 08/31/2024) | 386-672-8494 | 386-673-7856 |
DENNIS GENE GAINEY
| Status | Location Address | State License Number | Phone | Fax |
| INACTIVE |
P.O. BOX 1203 Bunnell, FL 32110 |
CFC046004 (Exp: 08/31/2026) | (386) 437-5637 | 386-437-3012 |
JOHN EDWARD GAMBONE
| Status | Location Address | Mailing Address | State License Number | Phone |
| ACTIVE |
15 HARGROVE LN PALM COAST, FL 32137 |
1G PALM COAST, FL 32137 |
EC13006037 (Exp: 08/31/2026) | 386-586-9144 |
LEONARD E GASPARY
| Status | Location Address | Phone | Fax |
| INACTIVE |
400 NORTH US HWY #1 ORMOND BEACH, FL 32174 |
(386)672-8494 | (386)673-7856 |
Inspection History
| Type | Request Date | Result | Inspector |
| BLD - BUILDING FINAL | 02/08/2024 | FINAL APPROVED | AGAETANO |
| Note: 2/7/2024 - PREVIOUS INSPECTION NOTES 2/7/24 1. Can not lower attic access to check attic 2. Duct work goin into attic in garage needs to be sealed better where it meets ceiling 3. Cook top requires breaker lock 4. Double oven requires a breaker lock Stopped inspection not ready NEC 422.31 2/2/2024 - PREVIOUS INSPECTION NOTES 02-02-2024 1. Lanai OUTLETS NOT gfci protected. 2. Energy calcs Design Information not on site. 3. No hot water. 4. Garage outlets not GFCI protected. 5. Holes in garage. Check all. 6. Kitchen GFCI circuits not indicated in kitchen. Inspection stopped. A full inspection is required. | |||
| BLD - BUILDING FINAL | 02/07/2024 | Disapproved -FEE REQUIRED | MKRASKI |
| Note: 2/7/24 1. Can not lower attic access to check attic 2. Duct work goin into attic in garage needs to be sealed better where it meets ceiling 3. Cook top requires breaker lock 4. Double oven requires a breaker lock Stopped inspection not ready 2/2/2024 - PREVIOUS INSPECTION NOTES 02-02-2024 1. Lanai OUTLETS NOT gfci protected. 2. Energy calcs Design Information not on site. 3. No hot water. 4. Garage outlets not GFCI protected. 5. Holes in garage. Check all. 6. Kitchen GFCI circuits not indicated in kitchen. Inspection stopped. A full inspection is required. | |||
| ROW - FINAL INSPECTION | 02/07/2024 | APPROVED | EMADISON |
| U-CROSS CONNECTION | 02/05/2024 | APPROVED | DHANEY |
| BLD - BUILDING FINAL | 02/02/2024 | Disapproved - NO FEE | AGAETANO |
| Note: 02-02-2024 1. Lanai OUTLETS NOT gfci protected. 2. Energy calcs Design Information not on site. 3. No hot water. 4. Garage outlets not GFCI protected. 5. Holes in garage. Check all. 6. Kitchen GFCI circuits not indicated in kitchen. Inspection stopped. A full inspection is required. | |||
| U -UTILITY RESIDENTIAL FINAL | 02/02/2024 | Disapproved - NO FEE | DHANEY |
| Note: Need sewer clean outs lowerd to ground level . (Note you will also need to call in Cross CN. Insp. . ) | |||
| U -UTILITY RESIDENTIAL FINAL | 02/02/2024 | FINAL APPROVED | DHANEY |
| Note: 2/1/2024 - PREVIOUS INSPECTION NOTES Need sewer clean outs lowerd to ground level . (Note you will also need to call in Cross CN. Insp. . ) | |||
| ROW - FINAL APRON (AFTER POUR) | 02/01/2024 | APPROVED | PFLANAGAN |
| Note: At the time of the inspection all minimum city requirements were met. It is the builders responsibiliy to ensure that nothing changes after this Inspection is approved. | |||
| ROW - STORMWATER FINAL | 01/31/2024 | APPROVED - AS NOTED | EMADISON |
| Note: ** 01/31/24 SOD LAID IN PLACE ALONG FENCE TO CONTAIN BARK MULCH OF THE RIGHT SIDE ** HOA approved the landscaping between the two properties along the right side property line. _________________________________________________________________________________________________________________________ Inspector Notes from Inspection 9465 Landscaping along the property lines were approved by the HOA where there is no easement between houses. 1/24/2024 - PREVIOUS INSPECTION NOTES | |||
| ROW FIELD SURVEY /GRADING CERTIFICATION | 01/30/2024 | APPROVED - AS NOTED | RGROSS |
| Note: Builder takes full responsibility for any future drainage issues that were approved by the HOA. 1/24/2024 - PREVIOUS INSPECTION NOTES ** 01/24/24 "Sec 300.03 C1f Flat work, i.e., slabs, walkways, hardscaping, patios, decking or AC pads are not allowed in any utility easements. Additionally, decorative objects, columns, light poles, mulch, stones, plantings or landscaping of any kind, is not allowed in the Right of Way (the swale area, between the edge of pavement and the property line)." ** AREAS NOTED ALONG RIGHT SIDE PROPERTY LINE AND ACROSS REAR PROPERTY LINE ALONG FENCE | |||
| ROW FIELD SURVEY /GRADING CERTIFICATION | 01/24/2024 | Disapproved - NO FEE | EMADISON |
| Note: ** 01/24/24 "Sec 300.03 C1f Flat work, i.e., slabs, walkways, hardscaping, patios, decking or AC pads are not allowed in any utility easements. Additionally, decorative objects, columns, light poles, mulch, stones, plantings or landscaping of any kind, is not allowed in the Right of Way (the swale area, between the edge of pavement and the property line)." ** AREAS NOTED ALONG RIGHT SIDE PROPERTY LINE AND ACROSS REAR PROPERTY LINE ALONG FENCE | |||
| FINAL SURVEY (OFFICE USE ONLY) | 01/24/2024 | APPROVED | EMADISON |
| FINAL SURVEY (OFFICE USE ONLY) | 01/18/2024 | Disapproved - NO FEE | EMADISON |
| Note: ** 01/18/24 NEED TO INDICATE IF BOTH ADJACENT LOTS ARE IEITHER VACANT OR IMPROVED LOTS ** IF IMPROVED NEED TO PROVIDE THE FINISH FLOOR ELEVATION OF THE LOT | |||
| ROW- PRE-APRON (PRE-POUR) | 11/21/2023 | APPROVED - AS NOTED | EMADISON |
| Note: ** 11/21/23 READY TO SET PAVERS ___________________________________________________________________________________________________________________ 11/15/2023 - PREVIOUS INSPECTION NOTES ** 11/15/23 ENSURE PAVER RESTRAINTS ARE A MINIMUM OF 8 INCHES DEEP BEFORE YOU POUR ** READY TO POUR APRON AND PAVER RESTRAINTS ** MAKE SURE THERE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL ** SCHEDULE NEXT PRE-POUR INSPECTION ONCE PAVER BASE HAS BEEN SPREAD AND COMPACTED ** DO NOT SET ANY PAVERS UNTIL THE NEXT PRE-POUR INSPECTION HAS BEEN APPROVED | |||
| ROW- PAVER RESTRAINTS | 11/15/2023 | APPROVED - AS NOTED | EMADISON |
| Note: ** 11/15/23 ENSURE PAVER RESTRAINTS ARE A MINIMUM OF 8 INCHES DEEP BEFORE YOU POUR ** READY TO POUR APRON AND PAVER RESTRAINTS ** MAKE SURE THERE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) | |||
| ROW- PRE-APRON (PRE-POUR) | 11/15/2023 | PARTIALLY APPROVED | EMADISON |
| Note: ** 11/15/23 ENSURE PAVER RESTRAINTS ARE A MINIMUM OF 8 INCHES DEEP BEFORE YOU POUR ** READY TO POUR APRON AND PAVER RESTRAINTS ** MAKE SURE THERE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL ** SCHEDULE NEXT PRE-POUR INSPECTION ONCE PAVER BASE HAS BEEN SPREAD AND COMPACTED ** DO NOT SET ANY PAVERS UNTIL THE NEXT PRE-POUR INSPECTION HAS BEEN APPROVED | |||
| ELECTRIC - EARLY POWER | 08/14/2023 | APPROVED | AGAETANO |
| Note: 8/11/2023 - PREVIOUS INSPECTION NOTES 08-11-2023 Bonding loop not connected. | |||
| ELECTRIC - EARLY POWER | 08/11/2023 | Disapproved -FEE REQUIRED | AGAETANO |
| Note: 08-11-2023 Bonding loop not connected. | |||
| LATH/BRICK/ WATER BARRIER | 06/09/2023 | APPROVED | TSTAUFFACHER |
| INSULATION | 05/26/2023 | APPROVED | AGAETANO |
| Note: Inspector Notes from Inspection 2420 New inspection due to canceled inspection New inspection due to canceled inspection 5/9/2023 - PREVIOUS INSPECTION NOTES 05-09-2023 1. Ground rods not proper distance. NEC 250. 2. Insulation installed in garage and ceilings. Please remove for wiring and plumbing inspection. 3. No head test. 5' head pressure test failed P2503.5.1 4. Electrical panel has been relocated to the hallway and a sub panel added. Please revise and submit to the building department. Please have revision on site for inspection. 5. Mechanical drawings not on site. Inspection stopped. 05-18-2023 Energy calcs not on site. Please have on site prior to next inspection. | |||
| ALL ROUGH | 05/18/2023 | APPROVED - AS NOTED | AGAETANO |
| Note: New inspection due to canceled inspection New inspection due to canceled inspection 5/9/2023 - PREVIOUS INSPECTION NOTES 05-09-2023 1. Ground rods not proper distance. NEC 250. 2. Insulation installed in garage and ceilings. Please remove for wiring and plumbing inspection. 3. No head test. 5' head pressure test failed P2503.5.1 4. Electrical panel has been relocated to the hallway and a sub panel added. Please revise and submit to the building department. Please have revision on site for inspection. 5. Mechanical drawings not on site. Inspection stopped. 05-18-2023 Energy calcs not on site. Please have on site prior to next inspection. | |||
| ALL ROUGH | 05/17/2023 | CANCELLED BY APPLICANT | WEB |
| Note: 5/9/2023 - PREVIOUS INSPECTION NOTES 05-09-2023 1. Ground rods not proper distance. NEC 250. 2. Insulation installed in garage and ceilings. Please remove for wiring and plumbing inspection. 3. No head test. 5' head pressure test failed P2503.5.1 4. Electrical panel has been relocated to the hallway and a sub panel added. Please revise and submit to the building department. Please have revision on site for inspection. 5. Mechanical drawings not on site. Inspection stopped. | |||
| ALL ROUGH | 05/17/2023 | CANCELLED BY APPLICANT | WEB |
| Note: New inspection due to canceled inspection 5/9/2023 - PREVIOUS INSPECTION NOTES 05-09-2023 1. Ground rods not proper distance. NEC 250. 2. Insulation installed in garage and ceilings. Please remove for wiring and plumbing inspection. 3. No head test. 5' head pressure test failed P2503.5.1 4. Electrical panel has been relocated to the hallway and a sub panel added. Please revise and submit to the building department. Please have revision on site for inspection. 5. Mechanical drawings not on site. Inspection stopped. | |||
| ALL ROUGH | 05/09/2023 | Disapproved -FEE REQUIRED | AGAETANO |
| Note: 05-09-2023 1. Ground rods not proper distance. NEC 250. 2. Insulation installed in garage and ceilings. Please remove for wiring and plumbing inspection. 3. No head test. 5' head pressure test failed P2503.5.1 4. Electrical panel has been relocated to the hallway and a sub panel added. Please revise and submit to the building department. Please have revision on site for inspection. 5. Mechanical drawings not on site. Inspection stopped. | |||
| WALL SHEATHING | 05/08/2023 | APPROVED | FWILLIS |
| ROOF VALLEY & METAL | 02/27/2023 | APPROVED | TSTAUFFACHER |
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 02/22/2023 | APPROVED | AGAETANO |
| Note: 1/30/2023 - PREVIOUS INSPECTION NOTES 1/27/2023 - PREVIOUS INSPECTION NOTES 1/26/2023 - PREVIOUS INSPECTION NOTES 01-26-2023 1. Down cells not exposed. 2. Truss layout not on site. Please organize engineering packet. 01-27-2023 Truss layout is too small and blurry to read. Please provide a large readable truss layout for inspection. 01-30-2023 1. Truss repair packet for trusses: E7H, G7, G9, G11, G13, G15, G17, G19, J1H, EH7, J3H, J5H, R7H, R22 not submitted to the building department for review. 2. G7, G9,G11, G13, G15, G17, G19 not installed as per plans. Truss repair indicates continuus and to the peak. 3. J3H, J5H, R7H - no notes on truss repair. Inspector will reinspect following building department review of truss repair. 4. A5 truss repair not nailed as per truss repair specs. | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 01/30/2023 | Disapproved -FEE REQUIRED | AGAETANO |
| Note: 1/27/2023 - PREVIOUS INSPECTION NOTES 1/26/2023 - PREVIOUS INSPECTION NOTES 01-26-2023 1. Down cells not exposed. 2. Truss layout not on site. Please organize engineering packet. 01-27-2023 Truss layout is too small and blurry to read. Please provide a large readable truss layout for inspection. 01-30-2023 1. Truss repair packet for trusses: E7H, G7, G9, G11, G13, G15, G17, G19, J1H, EH7, J3H, J5H, R7H, R22 not submitted to the building department for review. 2. G7, G9,G11, G13, G15, G17, G19 not installed as per plans. Truss repair indicates continuus and to the peak. 3. J3H, J5H, R7H - no notes on truss repair. Inspector will reinspect following building department review of truss repair. 4. A5 truss repair not naile as per truss repair specs. | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 01/27/2023 | Disapproved -FEE REQUIRED | AGAETANO |
| Note: 1/26/2023 - PREVIOUS INSPECTION NOTES 01-26-2023 1. Down cells not exposed. 2. Truss layout not on site. Please organize engineering packet. 01-27-2023 Truss layout is too small and blurry to read. Please prov ide a large readable truss layout for inspection. | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 01/26/2023 | Disapproved - NO FEE | AGAETANO |
| Note: 01-26-2023 1. Down cells not exposed. 2. Truss layoiut not on site. Please organize engineering packet. | |||
| FOUND SURVEY APPROVED (OFFICE) | 01/25/2023 | APPROVED | TBAKER |
| TIE BEAM / LINTEL | 10/24/2022 | APPROVED | AGAETANO |
| Note: 10/21/2022 - PREVIOUS INSPECTION NOTES 10-21-2022 Two missed down cells. Noted on drawings. | |||
| TIE BEAM / LINTEL | 10/21/2022 | Disapproved - NO FEE | AGAETANO |
| Note: 10-21-2022 Two missed down cells. Noted on drawings. | |||
| WILDLIFE CHECK - ENVIRONMENTAL | 10/04/2022 | APPROVED | JMYERS |
| MONOLITHIC SLAB | 09/19/2022 | APPROVED | AGAETANO |
| PLUMBING 1ST ROUGH UNDERGROUND | 09/14/2022 | APPROVED | MGIBSON |
| GRAVITY SEWER TEST | 09/14/2022 | APPROVED | MGIBSON |
| U - SEWER TIE IN | 09/14/2022 | APPROVED | MGIBSON |
| WATER METER INSTALLATION REQUEST | 09/01/2022 | APPROVED | CSTONE |
Review History
| Department | Status | Date In | Date Out |
| SW1 | COMPLETE | 08/24/2023 | 09/05/2023 |
| Note: Released By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 08/15/2023 | 08/15/2023 |
| Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM | |||
| ELEC | COMPLETE | 05/11/2023 | 05/12/2023 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 02/27/2023 | 03/01/2023 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 02/27/2023 | 03/01/2023 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| BLD | HOLD | 02/26/2023 | 02/27/2023 |
| Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM Wrong product approval number. Nothing comes up when that number is typed in. | |||
| BLD | COMPLETE | 02/01/2023 | 02/01/2023 |
| Note: Released By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 01/25/2023 | 01/25/2023 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 01/25/2023 | 01/25/2023 |
| Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 12/08/2022 | 12/12/2022 |
| Note: Released By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 11/28/2022 | 12/02/2022 |
| Note: Released By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 10/10/2022 | 10/10/2022 |
| Note: Released By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 08/03/2022 | 08/03/2022 |
| Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM | |||
| MECH | COMPLETE | 08/03/2022 | 08/04/2022 |
| Note: Released By: CHRIS PISCITELLI - (386)986-3782 - CPISCITELLI@PALMCOASTGOV.COM | |||
| ELEC | COMPLETE | 08/03/2022 | 08/03/2022 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| ZON | HOLD | 08/02/2022 | 08/03/2022 |
| Note: Held By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM Repeat comment: Color sheet: There can only be one body color. Please remove one. and resubmit color sheet for approval | |||
| MECH | HOLD | 08/02/2022 | 08/03/2022 |
| Note: Held By: CHRIS PISCITELLI - (386)986-3782 - CPISCITELLI@PALMCOASTGOV.COM 1. Energy Calcs need to be signed by the builder 2. Provide Duct layout signed by AC contractor (Third Request) | |||
| PLENV | COMPLETE | 08/02/2022 | 08/02/2022 |
| Note: Released By: JORDAN MYERS, C.F.M - (386)986-2320 - JMYERS@PALMCOASTGOV.COM The Approved After Action Report has been accepted. | |||
| ZON | HOLD | 07/26/2022 | 07/26/2022 |
| Note: Held By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM Please correct site plan as the turn around is not meeting the Land development code. I spoke to my Supervisor and turn around can not exceed 9 x 18 the. So where it measures 19 it will have to be reduced to no more than nine. This will allow parking space for one car. Please adjust plans accordingly. Color sheet Only one color allowed for base of the home please resubmit. | |||
| MECH | HOLD | 07/25/2022 | 07/25/2022 |
| Note: Held By: CHRIS PISCITELLI - (386)986-3782 - CPISCITELLI@PALMCOASTGOV.COM 1. Energy Calcs need to be signed by the builder 2. Provide Duct layout signed by AC contractor (Second Request) | |||
| ZON | HOLD | 07/25/2022 | 07/26/2022 |
| Note: Held By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM Please submit the letter of the HOA through the portal it needs to be on record with the permit. Please also include the new color sheet as two colors for the base arwe not allowed choose one and resubmit. Color sheet: There can only be one body color. Please remove one. | |||
| PLENV | HOLD | 07/25/2022 | 07/25/2022 |
| Note: Held By: JORDAN MYERS, C.F.M - (386)986-2320 - JMYERS@PALMCOASTGOV.COM Staff is waiting on the Approved After Action Report from FWC. | |||
| SW1 | COMPLETE | 07/25/2022 | 08/01/2022 |
| Note: Released By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 07/25/2022 | 07/25/2022 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| PLENV | HOLD | 07/20/2022 | 07/20/2022 |
| Note: Held By: JORDAN MYERS, C.F.M - (386)986-2320 - JMYERS@PALMCOASTGOV.COM Staff is waiting on the Approved After Action Report from FWC. | |||
| BADMIN | INFORMATION | 07/14/2022 | 07/14/2022 |
| Note: Marked INFORMATION By: BARBIE BEMBRY - (386)986-3780 - BUILDINGDIVISION@PALMCOASTGOV.COM Rename your files according to our document submittal requirements outlined on the permit portal. Upload the documents to the correct document type category (elevation A is used for model homes , any plan sheets should be uploaded under PLANS) | |||
| BADMIN | INFORMATION | 07/14/2022 | 07/14/2022 |
| Note: Marked INFORMATION By: BARBIE BEMBRY - (386)986-3780 - BUILDINGDIVISION@PALMCOASTGOV.COM Same comment as previously stated. ALL documents needs to be corrected. | |||
| ZON | HOLD | 07/14/2022 | 07/15/2022 |
| Note: Held By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM Repeat comments: Site plan: List the materials for the driveway. Please provide sets backs from the house to property line as I will not be approving the pool in this permit. Turn around: The Land Development Code requires that driveways either be "standard" - leading to a garage, circular or can have "turnarounds" and the City recognizes turnarounds as parking space size, which is 9’ wide by 18’ long. Additionally, the driveway/turnaround cannot be located within 5 feet of the side property line. Please adjust driveway accordling to meet the turnaround requirement. Color sheet: There can only be one body color. Please remove one. | |||
| ELEC | COMPLETE | 07/13/2022 | 07/13/2022 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| PLENV | HOLD | 06/30/2022 | 07/05/2022 |
| Note: Held By: JORDAN MYERS, C.F.M - (386)986-2320 - JMYERS@PALMCOASTGOV.COM Staff conducted a site visit on 7/5/22 and found multiple Gopher Tortoise burrows. Please either provide a Gopher Tortoise survey by a QEP that shows the burrow is not within 25ft of construction activities or an approved After Action Report from FWC after relocation activities have been completed. | |||
| BLD | COMPLETE | 06/29/2022 | 07/07/2022 |
| Note: Released By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM | |||
| CUSVC | COMPLETE | 06/29/2022 | 07/01/2022 |
| Note: Released By: HALEIGH HAND - - | |||
| ELEC | HOLD | 06/29/2022 | 06/29/2022 |
| Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. Need to reference the 2017 NEC 2. Submit a riser diagram for the generator 3. Submit manufacture specs for generator | |||
| ENGIN1 | COMPLETE | 06/29/2022 | 06/29/2022 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| LOCATE | COMPLETE | 06/29/2022 | 07/05/2022 |
| Note: Released By: CANDACE STONE - - CSTONE@PALMCOASTGOV.COM | |||
| MECH | HOLD | 06/29/2022 | 07/01/2022 |
| Note: Held By: CHRIS PISCITELLI - (386)986-3782 - CPISCITELLI@PALMCOASTGOV.COM 1. Energy Calcs need to be signed by the builder 2. Provide Duct layout signed by AC contractor | |||
| SW1 | COMPLETE | 06/29/2022 | 07/07/2022 |
| Note: Released By: ROBERT GROSS - (386)986-4769 - RGROSS@PALMCOASTGOV.COM | |||
| ZON | HOLD | 06/29/2022 | 06/30/2022 |
| Note: Held By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM Site plan: List the materials for the driveway. Please provide sets backs from the house to property line as I will not be approving the pool in this permit. Turn around: The Land Development Code requires that driveways either be "standard" - leading to a garage, circular or can have "turnarounds" and the City recognizes turnarounds as parking space size, which is 9’ wide by 18’ long. Additionally, the driveway/turnaround cannot be located within 5 feet of the side property line. Please adjust driveway accordling to meet the turnaround requirement. Elevation: Banding around Corners: Banding must wrap corners at least two feet Look at left side elevation. Color sheet: There can only be one body color. Please remove one. |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| REINSPECTION RESIDENTIAL | ¤40.00 | 02/08/2024 |
| PLAN REVIEW - REVISION | ¤32.50 | 02/08/2024 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 02/08/2024 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 02/08/2024 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 02/08/2024 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 01/27/2023 |
| PLAN REVIEW - REVISION | ¤32.50 | 01/24/2023 |
| PLAN REVIEW - REVISION | ¤32.50 | 01/24/2023 |
| PLAN REVIEW - REVISION | ¤32.50 | 01/24/2023 |
| PLAN REVIEW - REVISION | ¤32.50 | 01/24/2023 |
| WATER-METER | ¤467.09 | 08/09/2022 |
| ADJUSTMENT 50% | (¤844.55) | 08/09/2022 |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | 08/09/2022 |
| INSPECTION - RESIDENTIAL | ¤1,292.50 | 08/09/2022 |
| PLAN REVIEW - RESIDENTIAL | ¤366.60 | 08/09/2022 |
| CONNECTION FEES | ¤25.00 | 08/09/2022 |
| 3% FIRE IMPACT FEE CREDIT | (¤11.66) | 08/09/2022 |
| IMPACT FEE FIRE | ¤388.65 | 08/09/2022 |
| IMPACT FEE PARKS | ¤1,455.13 | 08/09/2022 |
| IMPACT FEE SCHOOL | ¤3,600.00 | 08/09/2022 |
| IMPACT FEE TRANSPORTATION | ¤3,224.00 | 08/09/2022 |
| 3% PARKS IMPACT FEE CREDIT | (¤43.65) | 08/09/2022 |
| SURCHARGE FS 533.721 | ¤5.21 | 08/09/2022 |
| SURCHARGE - FS 468.631 | ¤7.82 | 08/09/2022 |
| SW ENG - FOUNDATION SURVEY | ¤20.00 | 08/09/2022 |
| SW ENG INSPECTION 80 | ¤80.00 | 08/09/2022 |
| SW ENG PRE APRON | ¤30.00 | 08/09/2022 |
| SW ENG - REVIEW 20 | ¤20.00 | 08/09/2022 |
| SW ENG RES REVIEW 200 | ¤200.00 | 08/09/2022 |
| 3% TRANS IMPACT FEE CREDIT | (¤96.72) | 08/09/2022 |
| SEWER INSPECTION | ¤25.00 | 08/09/2022 |
| SEWER CAPITAL FACILITY | ¤4,939.76 | 08/09/2022 |
| WATER CAPITAL FACILITY FEE | ¤3,626.50 | 08/09/2022 |
| SITE PLAN 30 | ¤30.00 | 08/09/2022 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤19,199.18 |