I want to search for...
Permit #2022070365
Permit Details
Status: COED
| Parcel Id: 07-11-31-7010-00150-0320 |
| CONDITIONED SPACE: 2495 sqft |
| GARAGE: 470 sqft |
| OPENED PORCH (WITH ROOF) : 158 sqft |
| OPENED PORCH (WITH ROOF) : 83 sqft |
| Total Square Footage: 3206 sqft |
| Block: 00150 |
| Subdivision: 2137 - SECTION 10-FLORIDA PARK |
| Job Phone: 386-569-7882 |
| Location Address: 30 FLEMINGTON LN |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 07/29/2022 |
| NOC: RECORDED |
| Applicant name: VLADIMIR V PEREPECHKIN |
| Owner: BEACH REALTY OF WESTCHESTER INC |
|
Address 299 YACHT HARBOR DRIVE PALM COAST , FL 32137 |
| Lot: 0320 |
| Contracted Stated Job Value: ¤350,000.00 |
| Job Description: SINGLE FAMILY RESIDENTIAL |
| Type: CN |
Contractor
WISE CHOICE CUSTOM HOMES, INC.
| Status | Location Address | State License Number | Phone |
| ACTIVE |
77 SOUTHLAKE DR PALM COAST, FL 32137 |
CRC1328738 (Exp: 08/31/2026) | 386-569-7882 |
Sub Contractors
OLEG BELINSKIY
| Status | Location Address | State License Number | Phone |
| ACTIVE |
19 PINE CIRCLE DRIVE19 PALM COAST, FL 32167 |
CCC1325974 (Exp: 08/31/2026) | 386-263-7906 |
GLEN WILLIAM KEHLE
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
P. O. Box 353511 BUNNELL, FL 32110 |
CFC057241 (Exp: 08/31/2026) | (386) 447-4249 | (386) 437-8488 |
MAXIM BUDNIK
| Status | Location Address | State License Number |
| ACTIVE |
3 WAVECREST PL PALM COAST, FL 32164 |
CAC1818445 (Exp: 08/31/2026) |
MAXIM BUDNIK
| Status | Location Address | State License Number | Phone |
| ACTIVE |
9788 HALSEY RD JACKSONVILLE, FL 32246 |
EC13007415 (Exp: 08/31/2026) | 904-509-7306 |
Inspection History
| Type | Request Date | Result | Inspector |
| BLD - BUILDING FINAL | 08/18/2023 | FINAL APPROVED | AGAETANO |
| Note: 8/4/2023 - PREVIOUS INSPECTION NOTES 8/2/2023 - PREVIOUS INSPECTION NOTES 7/10/2023 - PREVIOUS INSPECTION NOTES 07-10-2023 1. Lanai GFCI outlet weatherproof cover not installed. 2. Energy calcs do not match. 3. Breaker size does not match in panel and as indicated on AHU. Two Heat breakers installed. 4. Guest bath toilet in back right does not fill properly. Inspection stopped. 08-02-2023 1. AC energy calcs do not match. Plesse submit and have on site. 2. Approved drawings not on site. 3. AC unit breaker and AC panel breaker not within range. Inspection stopped. 08-04-2023 Above note has not been addressed. Energy calcs do ot match AC. Please revise to the building department and have on site. | |||
| BLD - BUILDING FINAL | 08/04/2023 | Disapproved -FEE REQUIRED | AGAETANO |
| Note: 8/2/2023 - PREVIOUS INSPECTION NOTES 7/10/2023 - PREVIOUS INSPECTION NOTES 07-10-2023 1. Lanai GFCI outlet weatherproof cover not installed. 2. Energy calcs do not match. 3. Breaker size does not match in panel and as indicated on AHU. Two Heat breakers installed. 4. Guest bath toilet in back right does not fill properly. Inspection stopped. 08-02-2023 1. AC energy calcs do not match. Plesse submit and have on site. 2. Approved drawings not on site. 3. AC unit breaker and AC panel breaker not within range. Inspection stopped. 08-04-2023 Above note has not been addressed. Energy calcs do ot match AC. Please evise to the building department and have on site. | |||
| BLD - BUILDING FINAL | 08/02/2023 | Disapproved -FEE REQUIRED | AGAETANO |
| Note: 7/10/2023 - PREVIOUS INSPECTION NOTES 07-10-2023 1. Lanai GFCI outlet weatherproof cover not installed. 2. Energy calcs do not match. 3. Breaker size does not match in panel and as indicated on AHU. Two Heat breakers installed. 4. Guest bath toilet in back right does not fill properly. Inspection stopped. 08-02-2023 1. AC energy calcs do not match. Plesse submit and have on site. 2. Approved drawings not on site. 3. AC unit breaker and AC panel breaker not within range. Inspection stopped. | |||
| BLD - BUILDING FINAL | 07/10/2023 | Disapproved - NO FEE | AGAETANO |
| Note: 07-10-2023 1. Lanai GFCI outlet weatherproof cover not installed. 2. Energy calcs do not match. 3. Breaker size does not match in panel and as indicated on AHU. Two Heat breakers installed. 4. Guest bath toilet in back right does not fill properly. Inspection stopped. | |||
| ROW - STORMWATER FINAL | 06/22/2023 | APPROVED | RGROSS |
| U -UTILITY RESIDENTIAL FINAL | 06/22/2023 | FINAL APPROVED | JHARDING |
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 05/10/2023 | APPROVED | EMADISON |
| ROW FIELD SURVEY /GRADING CERTIFICATION | 05/10/2023 | APPROVED - AS NOTED | EMADISON |
| Note: ** 05/10/23 BUILDER NEEDS TO REMOVE PORTA-JOHN FROM IN FRONT OF VACANT AND REPAIR SOD AFTER ** BUILDER NEEDS TO REPAIR SWALE ACROSS STREET AND SOD TO MATCH EXISTING GRADE | |||
| ROW - FINAL APRON (AFTER POUR) | 05/10/2023 | FINAL APPROVED | EMADISON |
| Note: Inspector Notes from Inspection 9465 ** 05/10/23 BUILDER NEEDS TO REMOVE PORTA-JOHN FROM IN FRONT OF VACANT AND REPAIR SOD AFTER ** BUILDER NEEDS TO REPAIR SWALE ACROSS STREET AND SOD TO MATCH EXISTING GRADE | |||
| ELECTRIC - EARLY POWER | 05/02/2023 | APPROVED - AS NOTED | AGAETANO |
| Note: 5/1/2023 - PREVIOUS INSPECTION NOTES 2/27/2023 - PREVIOUS INSPECTION NOTES 02-27-2023 Multi[le ceiling lights and electrical panel not saffed off. 05-01-2023 Ceiling light in front right bedroom not safe off. 05-02-2023 FPL notified at 10:13 am. | |||
| ELECTRIC - EARLY POWER | 05/01/2023 | Disapproved -FEE REQUIRED | AGAETANO |
| Note: 2/27/2023 - PREVIOUS INSPECTION NOTES 02-27-2023 Multi[le ceiling lights and electrical panel not saffed off. 05-01-2023 Ceiling light in front right bedroom not safe off. | |||
| ROW- PRE-APRON (PRE-POUR) | 03/01/2023 | APPROVED | PFLANAGAN |
| Note: IT'S THE CONTRACTORS RESPONSIBILITY TO CHECK THE CULVERT PIPE ELEVATIONS BEFORE POUR THE CONCRETE FOR DRIVEWAY. | |||
| ELECTRIC - EARLY POWER | 02/27/2023 | Disapproved -FEE REQUIRED | AGAETANO |
| Note: 02-27-2023 Multi[le ceiling lights and electrical panel not saffed off. | |||
| U-CROSS CONNECTION | 02/27/2023 | APPROVED | DHANEY |
| ROW- PRE-APRON (PRE-POUR) | 02/24/2023 | CANCELLED BY APPLICANT | WEB |
| GRAVITY SEWER TEST | 02/08/2023 | APPROVED | MGIBSON |
| U - SEWER TIE IN | 02/08/2023 | APPROVED | MGIBSON |
| INSULATION | 01/23/2023 | APPROVED | AGAETANO |
| Note: Inspector Notes from Inspection 2420 1/17/2023 - PREVIOUS INSPECTION NOTES 1/13/2023 - PREVIOUS INSPECTION NOTES 01-13-2023 Electrical not complete. Stopped inspection. 01-17-2023 ADDRESS MUST BE POSTED AND PLAINLY VISIBLE TO INSPECTORS. IF ADDRESS IS NOT PLAINLY VISIBLE, INSPECTORS WILL NOT PERFORM INSPECTIONS AND A REINSPECTION FEE WILL BE ISSUED. Florida Building Code-Building Section 501.2. R319.1 Residential R319.1 Address identification. Buildings shall be provided with approved address identification. The address identification shall be legible and placed in a position that is visible from the street or road fronting the property. Address identification characters shall contrast with their background. Address numbers shall be Arabic numbers or alphabetical letters. Numbers shall not be spelled out. Each character shall be not less than 4 inches (102 mm) in height with a stroke width of not less than 0.5 inch (12.7 mm). Where required by the fire code official, address identification shall be provided in additional approved locations to facilitate emergency response. Where access is by means of a private road and the building address cannot be viewed from the public way, a monument, pole or other sign or means shall be used to identify the structure. Address identification shall be maintained. 01-18-2023 1. Kitchen vent not sealed at roof deck. Check at next inspection. | |||
| ALL ROUGH | 01/18/2023 | APPROVED - AS NOTED | AGAETANO |
| Note: 1/17/2023 - PREVIOUS INSPECTION NOTES 1/13/2023 - PREVIOUS INSPECTION NOTES 01-13-2023 Electrical not complete. Stopped inspection. 01-17-2023 ADDRESS MUST BE POSTED AND PLAINLY VISIBLE TO INSPECTORS. IF ADDRESS IS NOT PLAINLY VISIBLE, INSPECTORS WILL NOT PERFORM INSPECTIONS AND A REINSPECTION FEE WILL BE ISSUED. Florida Building Code-Building Section 501.2. R319.1 Residential R319.1 Address identification. Buildings shall be provided with approved address identification. The address identification shall be legible and placed in a position that is visible from the street or road fronting the property. Address identification characters shall contrast with their background. Address numbers shall be Arabic numbers or alphabetical letters. Numbers shall not be spelled out. Each character shall be not less than 4 inches (102 mm) in height with a stroke width of not less than 0.5 inch (12.7 mm). Where required by the fire code official, address identification shall be provided in additional approved locations to facilitate emergency response. Where access is by means of a private road and the building address cannot be viewed from the public way, a monument, pole or other sign or means shall be used to identify the structure. Address identification shall be maintained. 01-18-2023 1. Kitchen vent not sealed at roof deck. Check at next inspection. | |||
| ALL ROUGH | 01/17/2023 | Disapproved -FEE REQUIRED | AGAETANO |
| Note: 1/13/2023 - PREVIOUS INSPECTION NOTES 01-13-2023 Electrical not complete. Stopped inspection. 01-17-2023 ADDRESS MUST BE POSTED AND PLAINLY VISIBLE TO INSPECTORS. IF ADDRESS IS NOT PLAINLY VISIBLE, INSPECTORS WILL NOT PERFORM INSPECTIONS AND A REINSPECTION FEE WILL BE ISSUED. Florida Building Code-Building Section 501.2. R319.1 Residential R319.1 Address identification. Buildings shall be provided with approved address identification. The address identification shall be legible and placed in a position that is visible from the street or road fronting the property. Address identification characters shall contrast with their background. Address numbers shall be Arabic numbers or alphabetical letters. Numbers shall not be spelled out. Each character shall be not less than 4 inches (102 mm) in height with a stroke width of not less than 0.5 inch (12.7 mm). Where required by the fire code official, address identification shall be provided in additional approved locations to facilitate emergency response. Where access is by means of a private road and the building address cannot be viewed from the public way, a monument, pole or other sign or means shall be used to identify the structure. Address identification shall be maintained. | |||
| ALL ROUGH | 01/13/2023 | Disapproved - NO FEE | AGAETANO |
| Note: 01-13-2023 Electrical not complete. HVAC not complete Stopped inspection. | |||
| LATH/BRICK/ WATER BARRIER | 01/12/2023 | APPROVED | AGAETANO |
| Note: 1/11/2023 - PREVIOUS INSPECTION NOTES 1/9/2023 - PREVIOUS INSPECTION NOTES 01-09-2023 Wire lath is not lapped properly - ASTM C1063, per FBC 2512. Gable ends, wire lathe needs to be installed horizontally. 01-11-2023 Wire lath at gable end is not lapped properly - ASTM C1063, per FBC 2512. Gable ends, wire lathe needs to be installed horizontally. Check all areas and install as per manufacrurer's specs and ASTM. | |||
| LATH/BRICK/ WATER BARRIER | 01/11/2023 | Disapproved -FEE REQUIRED | AGAETANO |
| Note: 1/9/2023 - PREVIOUS INSPECTION NOTES 01-09-2023 Wire lath is not lapped properly - ASTM C1063, per FBC 2512. Gable ends, wire lathe needs to be installed horizontally. 01-11-2023 Wire lath at gable end is not lapped properly - ASTM C1063, per FBC 2512. Gable ends, wire lathe needs to be installed horizontally. Check all areas and install as per manufacrurer's specs and ASTM. | |||
| LATH/BRICK/ WATER BARRIER | 01/09/2023 | Disapproved - NO FEE | AGAETANO |
| Note: 01-09-2023 Wire lath is not lapped properly - ASTM C1063, per FBC 2512. Gable ends, wire lathe needs to be installed horizontally. | |||
| ROOF VALLEY & METAL | 12/16/2022 | APPROVED | AGAETANO |
| Note: Inspector Notes from Inspection 2460 12/5/2022 - PREVIOUS INSPECTION NOTES 12-05-2022 1. Fly rafters not installed and roof sheathing not nailed. 2. Sheet 6/7 Typical Gable end framing not installed as per plans. Additional bracing required only if A is greater than 60". 3. Straps not fastened at front gable garage. Inspection stopped. 12-06-2022 Please submit a revision for the back left exterior wall knee wall that has been built. No details found. Contractor can proceed at own risk. | |||
| WALL SHEATHING | 12/06/2022 | APPROVED | AGAETANO |
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 12/06/2022 | APPROVED - AS NOTED | AGAETANO |
| Note: 12/5/2022 - PREVIOUS INSPECTION NOTES 12-05-2022 1. Fly rafters not installed and roof sheathing not nailed. 2. Sheet 6/7 Typical Gable end framing not installed as per plans. Additional bracing required only if A is greater than 60". 3. Straps not fastened at front gable garage. Inspection stopped. 12-06-2022 Please submit a revision for the back left exterior wall knee wall that has been built. No details found. Contractor can proceed at own risk. | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 12/05/2022 | Disapproved - NO FEE | AGAETANO |
| Note: 12-05-2022 1. Fly rafters not installed and roof sheathing not nailed. 2. Sheet 6/7 Typical Gable end framing not installed as per plans. Additional bracing required only if A is greater than 60". 3. Straps not fastened at front gable garage. Inspection stopped. | |||
| TIE BEAM / LINTEL | 11/02/2022 | APPROVED | AGAETANO |
| Note: Inspector Notes from Inspection 2250 Contractor will tamp two small areas in the front areas. He will facetime inspector. | |||
| FOUND SURVEY APPROVED (OFFICE) | 10/20/2022 | APPROVED | TBAKER |
| MONOLITHIC SLAB | 10/06/2022 | APPROVED - AS NOTED | AGAETANO |
| Note: Contractor will tamp two small areas in the front areas. He will facetime inspector. | |||
| PLUMBING 1ST ROUGH UNDERGROUND | 09/27/2022 | APPROVED | MGIBSON |
| WATER METER INSTALLATION REQUEST | 08/04/2022 | APPROVED | CSTONE |
| WILDLIFE CHECK - ENVIRONMENTAL | 07/21/2022 | APPROVED | JMYERS |
Review History
| Department | Status | Date In | Date Out |
| MECH | COMPLETE | 08/10/2023 | 08/11/2023 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| MECH | COMPLETE | 07/24/2023 | 07/25/2023 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 10/19/2022 | 10/20/2022 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| ZON | HOLD | 10/19/2022 | 10/19/2022 |
| Note: Held By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM Mechanical equipment pad encroaching in platted 5' easement. | |||
| ZON | COMPLETE | 10/19/2022 | 10/19/2022 |
| Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM MOVE THE HOUSE BACK ALL ZONING CHANGES STILL GOOD | |||
| ELEC | COMPLETE | 07/28/2022 | 07/28/2022 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| ELEC | HOLD | 07/22/2022 | 07/25/2022 |
| Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM Electric load calcs do not match the living space of the house. NEC 2017 220.82 | |||
| MECH | COMPLETE | 07/22/2022 | 07/25/2022 |
| Note: Released By: CHRIS PISCITELLI - (386)986-3782 - CPISCITELLI@PALMCOASTGOV.COM | |||
| PLENV | COMPLETE | 07/15/2022 | 07/21/2022 |
| Note: Released By: JORDAN MYERS, C.F.M - (386)986-2320 - JMYERS@PALMCOASTGOV.COM Staff conducted a site visit on 7/21/22 and found no Gopher Tortoise or their burrows. Staff suggests placing silt fence as soon as possible to prevent tortoise from moving into the lot. | |||
| SWALE | COMPLETE | 07/13/2022 | 10/13/2022 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 07/11/2022 | 07/14/2022 |
| Note: Released By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM | |||
| CUSVC | COMPLETE | 07/11/2022 | 07/12/2022 |
| Note: Released By: LISA ASBILL - - lasbill@palmcoastgov.com | |||
| ELEC | HOLD | 07/11/2022 | 07/11/2022 |
| Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM Submit electric load calcs and riser diagram | |||
| ENGIN1 | COMPLETE | 07/11/2022 | 07/13/2022 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| LOCATE | COMPLETE | 07/11/2022 | 07/14/2022 |
| Note: Released By: CANDACE STONE - - CSTONE@PALMCOASTGOV.COM | |||
| MECH | HOLD | 07/11/2022 | 07/11/2022 |
| Note: Held By: CHRIS PISCITELLI - (386)986-3782 - CPISCITELLI@PALMCOASTGOV.COM Energy Calcs need to be signed by the builder per 107.1 FBC Residential 2020 7th edition | |||
| SW1 | COMPLETE | 07/11/2022 | 07/18/2022 |
| Note: Released By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 07/11/2022 | 07/15/2022 |
| Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| PLAN REVIEW - REVISION | ¤32.50 | 08/23/2023 |
| PLAN REVIEW - REVISION | ¤32.50 | 08/23/2023 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 08/23/2023 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 08/23/2023 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 08/23/2023 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 08/23/2023 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 08/23/2023 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 08/23/2023 |
| CONNECTION FEES | ¤1,077.88 | 07/29/2022 |
| 3% FIRE IMPACT FEE CREDIT | (¤11.66) | 07/29/2022 |
| IMPACT FEE FIRE | ¤388.65 | 07/29/2022 |
| IMPACT FEE PARKS | ¤1,455.13 | 07/29/2022 |
| IMPACT FEE SCHOOL | ¤3,600.00 | 07/29/2022 |
| IMPACT FEE TRANSPORTATION | ¤1,764.00 | 07/29/2022 |
| WATER -IRRIGATION INSPECTION | ¤25.00 | 07/29/2022 |
| 3% PARKS IMPACT FEE CREDIT | (¤43.65) | 07/29/2022 |
| SURCHARGE FS 533.721 | ¤10.49 | 07/29/2022 |
| SURCHARGE - FS 468.631 | ¤15.73 | 07/29/2022 |
| SW ENG - FOUNDATION SURVEY | ¤20.00 | 07/29/2022 |
| SW ENG INSPECTION 80 | ¤80.00 | 07/29/2022 |
| SW ENG PRE APRON | ¤30.00 | 07/29/2022 |
| SW ENG - REVIEW 20 | ¤20.00 | 07/29/2022 |
| SW ENG RES REVIEW 200 | ¤200.00 | 07/29/2022 |
| 3% TRANS IMPACT FEE CREDIT | (¤52.92) | 07/29/2022 |
| SEWER CREDIT | (¤1,147.00) | 07/29/2022 |
| SEWER INSPECTION | ¤25.00 | 07/29/2022 |
| SEWER CAPITAL FACILITY | ¤4,939.76 | 07/29/2022 |
| WATER CAPITAL FACILITY FEE | ¤3,626.50 | 07/29/2022 |
| SITE PLAN 30 | ¤30.00 | 07/29/2022 |
| WATER- TURN ON | ¤25.00 | 07/29/2022 |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | 07/29/2022 |
| INSPECTION - RESIDENTIAL | ¤962.50 | 07/29/2022 |
| PLAN REVIEW - RESIDENTIAL | ¤273.00 | 07/29/2022 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤17,648.41 |