I want to search for...

Permit #2022070575

Permit Details

Status: COED

Parcel Id: 07-11-31-7023-00240-0300
CONDITIONED SPACE: 2031 sqft
GARAGE: 748 sqft
ENCLOSE EXISTING PORCH TO LIVING : 268 sqft
OPENED PORCH (WITH ROOF) : 140 sqft
Total Square Footage: 3187 sqft
Block: 00240
Subdivision: 2191 - SECTION 23-WYNNFIELD
Job Phone: 386-283-7499
Location Address: 7 WHITTLESEY LN
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 08/05/2022
NOC: RECORDED
Applicant name: WILLIAM ROBERT BARRICK
Owner: JMR III LLC

Address

PO BOX 9

CISSNA PARK, IL 60924

Lot: 0300
Contracted Stated Job Value: ¤273,387.00
Job Description: single family residence
Type: CN

Contractor

RBI ENTERPRISES INC
Status Location Address State License Number Phone
CANCEL

10 WHITTINGTON DR

PALM COAST, FL 32164

RB29003845 (Exp: 08/31/2025) 386-585-4097

Sub Contractors

WILLIAM ROBERT BARRICK
Status Location Address State License Number Phone
CANCEL

21 CEDARWOOD CT

PALM COAST, FL 32137

RC29027799 (Exp: 08/31/2023) 229-375-9123
DAVID SCOTT MORRIS
Status Location Address State License Number Phone
INACTIVE

63 LEIDEL DR

PALM COAST, FL 32137

ER13015750 (Exp: 08/31/2026) 386-569-7262
GARY LLOYD SHEFFIELD
Status Location Address State License Number Phone
ACTIVE

PO BOX 912

PALM COAST, FL 32164

CAC1820539 (Exp: 08/31/2026) 386-264-0550
JONATHAN M PEARSON
Status Location Address State License Number Phone Fax
ACTIVE

209 N FORSYTH ST

BUNNELL, FL 32110

CFC1425941 (Exp: 08/31/2026) 386-597-0944 386-437-4996

Inspection History

Type Request Date Result Inspector
BLD - BUILDING FINAL 07/27/2023 FINAL APPROVED RSIMS
Note: 7/26/2023 - PREVIOUS INSPECTION NOTES 1. Light @ back garage door is not working 2. Extra construction materials and doc boxes need to be removed before final 3. AHU breaker is undersized 4. No hot water at kitchen island sink 5. Spare guest bathroom door leading to lani requires a switched light 6. Microwave hood vent not connected to duct
U -UTILITY RESIDENTIAL FINAL 07/27/2023 FINAL APPROVED JHARDING
Note: 7/26/2023 - PREVIOUS INSPECTION NOTES 1-repair or replace water meter box,2-pep circuit breaker required to be 20 amp stand alone-no Test 7/25/2023 - PREVIOUS INSPECTION NOTES need access to Epanel for pep circuit breaker inspect/replair/replace damaged water meter box-contact utiity rsyndor@palmcoastgov.com(Rich)
U -UTILITY RESIDENTIAL FINAL 07/26/2023 Disapproved -FEE REQUIRED LFITZGERALD
Note: 1-repair or replace water meter box,2-pep circuit breaker required to be 20 amp stand alone-no Test 7/25/2023 - PREVIOUS INSPECTION NOTES need access to Epanel for pep circuit breaker inspect/replair/replace damaged water meter box-contact utiity rsyndor@palmcoastgov.com(Rich)
BLD - BUILDING FINAL 07/26/2023 Disapproved -FEE REQUIRED MKRASKI
Note: 1. Light @ back garage door is not working 2. Extra construction materials and doc boxes need to be removed before final 3. AHU breaker is undersized 4. No hot water at kitchen island sink 5. Spare guest bathroom door leading to lani requires a switched light 6. Microwave hood vent not connected to duct
U -UTILITY RESIDENTIAL FINAL 07/25/2023 Disapproved -FEE REQUIRED LFITZGERALD
Note: need access to Epanel for pep circuit breaker inspect/replair/replace damaged water meter box-contact utiity rsyndor@palmcoastgov.com(Rich)
U-CROSS CONNECTION 07/25/2023 APPROVED - AS NOTED LFITZGERALD
Note: has potable irrigation with PVB installed-no cross connection
ROW - FINAL APRON (AFTER POUR) 07/24/2023 APPROVED GBERTOLA
Note: At the time of the inspection all minimum city requirements were met. It is the builders responsibility to ensure that nothing changes after this Inspection is approved.
ROW - STORMWATER FINAL 07/24/2023 APPROVED GBERTOLA
Note: CORRECTION WERE MADE At the time of the inspection all minimum city requirements were met. It is the builders responsibility to ensure that nothing changes after this Inspection is approved.
ROW- FINAL SURVEY/GRADING CERTIFICATION 07/24/2023 APPROVED GBERTOLA
Note: 7/24/23= CORRECTION WERE MADE At the time of the inspection all minimum city requirements were met. It is the builders responsibility to ensure that nothing changes after this Inspection is approved.
ROW FIELD SURVEY /GRADING CERTIFICATION 07/24/2023 APPROVED GBERTOLA
Note: 7/24/23= CORRECTION WERE MADE At the time of the inspection all minimum city requirements were met. It is the builders responsibility to ensure that nothing changes after this Inspection is approved. +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 06/28/23= I SPOKE TO THE CM AND THE OWNER OF THE COMPANY AND THEY WILL RE GRADE THE BACK YARD AND BOTH SIDES OF THE HOUSE CREATING A W SWALE TO THE FRONT AND A BERM ON THE RIGHT SIDE ALSO TO HOLD A STORMWATER ON YOUR SITE . IN THE BACK YARD WATER IS COMING INSIDE THE COVER LANAI, NEED TO LOWER 10 FT 6 INCH Sod elevations adjacent to the structure are 4” below the FFE for block and 6” for wood frame structures. (D)?Drainage from the structure is to be a 6 inch (5%) minimum slope for the first 10’.(E) PER GBERTOLA +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 06/21/23= DRAINAGE CONVAYANCE IS NOT CONSISTENT IMPACTING THE NEIGHBORING LOTS. NOTE TO THE INSPECTOR: WHEN FINAL SURVEY IS REVISE MAKE SURE IS NOT WATER RUNNING TO THE NEGHBORING LOTS . ALSO BUILDER NEED TO CHANGE THE DIRECTION OF THE DOWNSPOUT FROM THE GUTTER IS IMPCTING THE HOME ON THE SIDE WITH THE STORMWATER
ROW- PROJECT STATUS 07/18/2023 APPROVED GBERTOLA
Note: 7/18/23= MEETING WITH THE CM FOR THE GRADING ON THE SIDE AND BACK OF PROPERTY. STILL NEED TO WAIT FOR FINAL SURVEY
ROW - DRAINAGE 06/28/2023 APPROVED GBERTOLA
Note: 6/28/23=correction were made 6/21/2023 - PREVIOUS INSPECTION NOTES 06/21/23= BUILDER NEED TO CHANGE THE DIRECTION OF THE DOWNSPOUT FROM THE GUTTER IS IMPACTING THE HOME ON THE SIDE WITH THE STORMWATER INSPECTOR BE BACK 6/28/23= . House #9 says builder put on Super Gutters and directed them to her home and it is now flooding. Could RBI possibly re-direct water discharge to the front?
ROW - DRAINAGE 06/21/2023 Disapproved - NO FEE GBERTOLA
Note: 06/21/23= BUILDER NEED TO CHANGE THE DIRECTION OF THE DOWNSPOUT FROM THE GUTTER IS IMPACTING THE HOME ON THE SIDE WITH THE STORMWATER INSPECTOR BE BACK 6/28/23= . House #9 says builder put on Super Gutters and directed them to her home and it is now flooding. Could RBI possibly re-direct water discharge to the front?
ROW- PRE-APRON (PRE-POUR) 06/05/2023 APPROVED FSLADISH
Note: 06/05/23 PIPES ARE GOOD. LOOKED GOOD AT TIME OF INSPECTION. READY TO POUR. AT THE TIME OF THE INSPECTION CULVERT PIPE IS GOOD IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD DOUBLE CHECK CULVERT ELEVATIONS BEFORE POURING. MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL
ELECTRIC - EARLY POWER 04/26/2023 APPROVED - AS NOTED MKRASKI
Note: Emailed FPL @ 2:15 PM
GRAVITY SEWER TEST 04/10/2023 APPROVED MGIBSON
U - SEWER TIE IN 04/10/2023 APPROVED MGIBSON
PEP TANK INSTALLATION REQUEST 03/06/2023 APPROVED TSCHWEERS
Note: 3/3/2023 11:35:29 AM- PREVIOUS INSPECTION NOTES 3/2/2023 Dumpster in the way of tank.
PEP TANK INSTALLATION REQUEST 03/02/2023 Disapproved - NO FEE TSCHWEERS
Note: 3/2/2023 Dumpster in the way of tank.
LATH/BRICK/ WATER BARRIER 02/16/2023 APPROVED MKRASKI
INSULATION 02/16/2023 APPROVED MKRASKI
ALL ROUGH 02/10/2023 APPROVED - AS NOTED JSTEWART
Note: 2/10/2023- previous notes have been rectified EXCEPT #3 (specs show more screws not center brackets), and #2 need manufacturer specs on screws (2 or 3 in jamb) WILL CHECK AT INSULATION. 2/8/2023 - PREVIOUS INSPECTION NOTES 1. Romex around SGD's not strapped properly 2. Large slider missing anchors 3. Double window missing mullbar bracket and anchors 4. Transome window missing in back bathroom 5. Exhaust fan duct needs to be supported every 4' Stopped inspection @ kitchen, make sure all windows are anchored properly
ALL ROUGH 02/08/2023 Disapproved - NO FEE MKRASKI
Note: 1. Romex around SGD's not strapped properly 2. Large slider missing anchors 3. Double window missing mullbar bracket and anchors 4. Transome window missing in back bathroom 5. Exhaust fan duct needs to be supported every 4' Stopped inspection @ kitchen, make sure all windows are anchored properly
ROOF VALLEY & METAL 12/08/2022 APPROVED MKRASKI
ROOF SHEATHING / BRACES/TIES/DOWN CELL 12/07/2022 APPROVED MKRASKI
ROOF SHEATHING / BRACES/TIES/DOWN CELL 12/06/2022 Disapproved -FEE REQUIRED LMILLER
Note: 12/2/2022 - PREVIOUS INSPECTION NOTES 1. Truss T30 needs engineered letter and repair 2. Truss T21 needs engineered letter and repair 3. Anchor missing over back door to the garage (leading outside) Stopped inspection 12-6-22 First 2 items checked from the list above wee not resolved, no letter on site for repairs. inspection stopped, make all corrections listed above prior to re-calling the inspection
WALL SHEATHING 12/02/2022 APPROVED MKRASKI
ROOF SHEATHING / BRACES/TIES/DOWN CELL 12/02/2022 Disapproved - NO FEE MKRASKI
Note: 1. Truss T30 needs engineered letter and repair 2. Truss T21 needs engineered letter and repair 3. Anchor missing over back door to the garage (leading outside) Stopped inspection
FOUND SURVEY APPROVED (OFFICE) 12/01/2022 APPROVED TBAKER
TIE BEAM / LINTEL 11/02/2022 APPROVED MKRASKI
MONOLITHIC SLAB 10/21/2022 APPROVED MKRASKI
MONOLITHIC SLAB 10/20/2022 Disapproved - NO FEE MKRASKI
Note: Back deep footing pads require per plans 4 #5s tied each way
PLUMBING 1ST ROUGH UNDERGROUND 10/17/2022 APPROVED MGIBSON
ROW - DRAINAGE 10/06/2022 APPROVED RGROSS
Note: Builder has complied. 9/30/2022 - PREVIOUS INSPECTION NOTES 09/30/22 NEED TO INSTALL SILT FENCE ALL AROUND THE CONSTRUCTION SITE AND ALL THE WAY DOWN TO THE SWALE ON THE DOWNSTREAM Erosion Control Inspection (119), Section 300.04 Lot Grading Permit Requirements for Vacant Lots
ROW - DRAINAGE 09/30/2022 Disapproved -FEE REQUIRED GBERTOLA
Note: 09/30/22 NEED TO INSTALL SILT FENCE ALL AROUND THE CONSTRUCTION SITE AND ALL THE WAY DOWN TO THE SWALE ON THE DOWNSTREAM Erosion Control Inspection (119), Section 300.04 Lot Grading Permit Requirements for Vacant Lots inspector be back on 10/6/22
WATER METER INSTALLATION REQUEST 08/17/2022 APPROVED CSTONE

Review History

Department Status Date In Date Out
MECH COMPLETE 07/21/2023 07/24/2023
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
BADMIN INFORMATION 06/26/2023 06/26/2023
Note: Marked INFORMATION By: MICHELLE RAMOS - - MRAMOS@PALMCOASTGOV.COM Unable to process final survey. NOC is expired. Please submit current NOC and resubmit final survey.
BLD COMPLETE 02/09/2023 02/14/2023
Note: Released By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM
ENGIN1 COMPLETE 02/02/2023 02/03/2023
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
SW1 COMPLETE 02/02/2023 02/07/2023
Note: Released By: GABRIEL BERTOLA - (386)986-7660 - GBERTOLA@PALMCOASTGOV.COM
ZON COMPLETE 02/02/2023 02/03/2023
Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM
BLD COMPLETE 12/02/2022 12/05/2022
Note: Released By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM
ENGIN1 COMPLETE 12/01/2022 12/01/2022
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
ZON COMPLETE 12/01/2022 12/01/2022
Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM
ZON COMPLETE 08/04/2022 08/04/2022
Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM
BLD COMPLETE 07/27/2022 07/27/2022
Note: Released By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM
ZON HOLD 07/27/2022 07/28/2022
Note: Held By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM Front setback should be from the closet point to property line. Should be from the right side of garage to property line.
ENGIN1 COMPLETE 07/27/2022 07/27/2022
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
SW1 COMPLETE 07/27/2022 08/03/2022
Note: Released By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM
BLD HOLD 07/26/2022 07/27/2022
Note: Held By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM All comments below per the 2020 Florida Building Code REVIEW COMMENTS: 1. OK 2. Provide 20 min door between the living area and the garage R302.5.1
ZON HOLD 07/26/2022 07/27/2022
Note: Held By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM Repeat comment: Issue not addressed Site Plan; Missing the rear setback of home
SWALE COMPLETE 07/14/2022 10/20/2022
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
BLD HOLD 07/13/2022 07/18/2022
Note: Held By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM All comments below per the 2020 Florida Building Code REVIEW COMMENTS: 1. Provide a legible Product Approval Sheet. Per F.S. 471.025 and F.A.C. 61 G15-23.005. 2. Provide 20 min door between the living area and the garage R302.5.1
CUSVC COMPLETE 07/13/2022 07/14/2022
Note: Released By: LISA ASBILL - - lasbill@palmcoastgov.com
ELEC COMPLETE 07/13/2022 07/15/2022
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
ENGIN1 COMPLETE 07/13/2022 07/14/2022
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
LOCATE COMPLETE 07/13/2022 07/14/2022
Note: Released By: CANDACE STONE - - CSTONE@PALMCOASTGOV.COM
MECH COMPLETE 07/13/2022 07/14/2022
Note: Released By: CHRIS PISCITELLI - (386)986-3782 - CPISCITELLI@PALMCOASTGOV.COM
SW1 COMPLETE 07/13/2022 07/19/2022
Note: Released By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM
ZON HOLD 07/13/2022 07/19/2022
Note: Held By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM Sitte Plan; Missing the rear setback of home

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
PLAN REVIEW - REVISION ¤32.50 07/28/2023
PLAN REVIEW - REVISION ¤32.50 07/28/2023
REINSPECTION RESIDENTIAL ¤40.00 07/28/2023
REINSPECTION RESIDENTIAL ¤40.00 07/28/2023
REINSPECTION FEE ¤40.00 07/28/2023
REINSPECTION FEE ¤40.00 07/28/2023
SW ENG REINSPECTION 20 ¤20.00 07/28/2023
SW ENG - INSPECTION 20 ¤20.00 07/28/2023
SW ENG - INSPECTION 20 ¤20.00 07/28/2023
SW ENG - INSPECTION 20 ¤20.00 07/28/2023
SW ENG - INSPECTION 20 ¤20.00 07/28/2023
SW ENG INSPECTION 80 ¤80.00 08/05/2022
SW ENG PRE APRON ¤30.00 08/05/2022
SW ENG - REVIEW 20 ¤20.00 08/05/2022
SW ENG RES REVIEW 200 ¤200.00 08/05/2022
3% TRANS IMPACT FEE CREDIT (¤52.92) 08/05/2022
SEWER CREDIT (¤1,147.00) 08/05/2022
SEWER INSPECTION ¤25.00 08/05/2022
SEWER CAPITAL FACILITY ¤4,939.76 08/05/2022
WATER CAPITAL FACILITY FEE ¤3,626.50 08/05/2022
SITE PLAN 30 ¤30.00 08/05/2022
SURCHARGE FS 533.721 ¤3.29 08/05/2022
SURCHARGE - FS 468.631 ¤4.94 08/05/2022
SW ENG - FOUNDATION SURVEY ¤20.00 08/05/2022
WATER-METER ¤467.09 08/05/2022
WATER- TURN ON ¤25.00 08/05/2022
WATER- TURN ON ¤25.00 08/05/2022
ADJUSTMENT 50% (¤509.20) 08/05/2022
ADMINISTRATIVE RESIDENTIAL ¤30.00 08/05/2022
INSPECTION - RESIDENTIAL ¤770.00 08/05/2022
PLAN REVIEW - RESIDENTIAL ¤218.40 08/05/2022
CONNECTION FEES ¤1,077.88 08/05/2022
3% FIRE IMPACT FEE CREDIT (¤11.66) 08/05/2022
IMPACT FEE FIRE ¤388.65 08/05/2022
IMPACT FEE PARKS ¤1,455.13 08/05/2022
IMPACT FEE SCHOOL ¤3,600.00 08/05/2022
IMPACT FEE TRANSPORTATION ¤1,764.00 08/05/2022
WATER -IRRIGATION INSPECTION ¤25.00 08/05/2022
WATER -IRRIGATION INSPECTION ¤25.00 08/05/2022
3% PARKS IMPACT FEE CREDIT (¤43.65) 08/05/2022
Fees Total Due: ¤0.00 Total Paid: ¤17,411.21