I want to search for...

Permit #2022070582

Permit Details

Status: COED

Parcel Id: 07-11-31-7007-00450-0100
CONDITIONED SPACE: 1906 sqft
GARAGE: 400 sqft
OPENED PORCH (WITH ROOF) : 20 sqft
Total Square Footage: 2326 sqft
Block: 00450
Subdivision: 2185 - SECTION 7-FLORIDA PARK
Job Phone: 475-276-4384
Location Address: 87 FREEPORT LN
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 02/02/2023
NOC: RECORDED
Applicant name: WADE GILMER JURNEY JR
Owner: NATIONAL HOME CORPORATION

Address

4850 TAMIAMI TRAIL N

NAPLES, FL 34103

Lot: 0100
Contracted Stated Job Value: ¤240,639.00
Job Description: Single Family Residence
Type: CN

Contractor

NATIONAL HOME CORPORATION
Status Location Address Mailing Address State License Number Phone
INACTIVE

1080 HOLCOMB BRIDGE ROAD

,

BLDG 100 - 330

ROSWELL , GA 30076

CBC1257700 (Exp: 08/31/2026) 471-817-1259

Sub Contractors

DUSTIN L ESTEP
Status Location Address State License Number Phone Fax
ACTIVE

2041 N HIAWASSEE RD

APOPKA, FL 32703

CCC1330971 (Exp: 08/31/2026) 407-702-0206 352-988-6629
JASON PATRICK RIBOCK
Status Location Address State License Number Phone
INACTIVE

620 E PINE ST

, 0

ES12001313 (Exp: 08/31/2026) 407-625-0257
DANIEL P GREGOIRE
Status Location Address State License Number Phone
INACTIVE

64 W. CENTRAL AVENUE

LAKE WALES, FL 33853

CFC057378 (Exp: 08/31/2024) (863)696-3737
RANDALL SCOTT ROSENFELD
Status Location Address State License Number Phone
ACTIVE

234 N WHITNEY ST

PALM COAST, FL 32084

CAC1816641 (Exp: 08/31/2026) 904-599-0082

Inspection History

Type Request Date Result Inspector
BLD - BUILDING FINAL 08/12/2024 FINAL APPROVED JSTEWART
Note: 8/8/2024 - PREVIOUS INSPECTION NOTES *** NOTES ADDED BY JSTEWART 8/8/2024 10:49:42 AM *** 1. Please raise ODU pad for 3" clearence. FBCR M1305.1.4.1 2. Please install PVC piping and secure to wall at hot water preassure release dicharge, between 6" and 24" off grade.
BLD - BUILDING FINAL 08/08/2024 Disapproved - NO FEE JSTEWART
Note: *** NOTES ADDED BY JSTEWART 8/8/2024 10:49:42 AM *** 1. Please raise ODU pad for 3" clearence. FBCR M1305.1.4.1 2. Please install PVC piping and secure to wall at hot water preassure release dicharge, between 6" and 24" off grade.
ROW - FINAL APRON (AFTER POUR) 07/31/2024 APPROVED EMADISON
ROW - STORMWATER FINAL 07/31/2024 APPROVED EMADISON
U -UTILITY RESIDENTIAL FINAL 07/31/2024 APPROVED - AS NOTED LFITZGERALD
Note: *** NOTES ADDED BY LFITZGERALD 7/31/2024 2:41:40 PM *** lower sewer clean out so not chopped by mower-flush to grade
ROW FIELD SURVEY /GRADING CERTIFICATION 07/30/2024 APPROVED EMADISON
Note: 7/26/2024 - PREVIOUS INSPECTION NOTES ** 07/26/24 RIGHT REAR ALONG PROPERTY BUILDER NEEDS TO RE-ESTABLISH THE INSIDE SWALE KEEP IN MIND The top of slope of “W” swales along the property lines shall be a minimum of 0.30 of a foot higher than the toe OF THE SLOPE ** NOTE WHITE PAINT WHERE CORRECTIONS ARE REQUIRED
ROW- FINAL SURVEY/GRADING CERTIFICATION 07/26/2024 APPROVED EMADISON
Note: ** 07/26/24 REVIEWED FINAL SURVEY WITH CITY SURVEYORS DUE TO CHANGE IN SLAB ELEVATION WHO HAS DETERMINED THAT SURVEY SHOWS DRSINAGE WILL WORK AND ELEVATION OF STRUCTURE WILL NOT HAVE ANY NEGATIVE IMPACT ON ADJACENT PROPERTIES.
ROW FIELD SURVEY /GRADING CERTIFICATION 07/26/2024 Disapproved - NO FEE EMADISON
Note: ** 07/26/24 RIGHT REAR ALONG PROPERTY BUILDER NEEDS TO RE-ESTABLISH THE INSIDE SWALE KEEP IN MIND The top of slope of “W” swales along the property lines shall be a minimum of 0.30 of a foot higher than the toe OF THE SLOPE ** NOTE WHITE PAINT WHERE CORRECTIONS ARE REQUIRED
U-CROSS CONNECTION 07/22/2024 APPROVED DHANEY
ELECTRIC - EARLY POWER 07/18/2024 APPROVED JWALKER
Note: 8/11/2023 - PREVIOUS INSPECTION NOTES 08-11-2023 Devices and outlets not installed, no drywall, electrical panel not complete.
ROW- PRE-APRON (PRE-POUR) 05/23/2024 APPROVED - AS NOTED EMADISON
Note: ** 05/23/24 READY TO POUR ** At the time of the inspection all minimum city requirements were met. It is the builders responsibility to ensure that nothing changes after this Inspection is approved. This includes but is not limited to, the Culvert Pipe Elevation from the time of the inspection approval to the concrete pour. **MAKE SURE THERE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL
U - SEWER TIE IN 05/03/2024 APPROVED - AS NOTED MGIBSON
Note: Inspector Notes from Inspection 2060 REMOVE ALL COQUINA ROCK BEFORE BACKFILLING PLUMBING TRENCHES, AND HAVE PORTABLE RESTROOM BEFORE NEXT INSPECTION THIS WAS A VIRTUAL INSPECTION
GRAVITY SEWER TEST 05/03/2024 APPROVED - AS NOTED MGIBSON
Note: Inspector Notes from Inspection 2060 REMOVE ALL COQUINA ROCK BEFORE BACKFILLING PLUMBING TRENCHES, AND HAVE PORTABLE RESTROOM BEFORE NEXT INSPECTION THIS WAS A VIRTRUAL INSPECTION
INSULATION 04/03/2024 APPROVED BTAYLOR
Note: 4/2/2024 - PREVIOUS INSPECTION NOTES 4/2/24 Multiple water supply pipes and plumbing vent, and drian pipes missing fire blocking at the top plates and floor penetrations. Check all. 3/22/2024 - PREVIOUS INSPECTION NOTES 3/22/24- Walked building with superintedent, has a list of items that need to be addressed before moving forward. (Firestop, fastening of romex, register boots corners mastic, and seal for drywall, etc). Please on reinspect check mechanicals (all rough) and Insulation. 2/22/2024 - PREVIOUS INSPECTION NOTES 2/21/2024 - PREVIOUS INSPECTION NOTES 2/8/2024 - PREVIOUS INSPECTION NOTES Inspector Notes from Inspection 2420 1/24/24- Please obtain a revision of energy calcs for ducts on 2nd floor installed, sizes dont match. and above door wall returns calls for 24x4=area of 96 square inches, installed is 6x10=area of 60 square inches. WILL CHECK AT INSULATION 1/17/2024 - PREVIOUS INSPECTION NOTES 11/30/2023 - PREVIOUS INSPECTION NOTES 11/17/2023 - PREVIOUS INSPECTION NOTES 11/13/2023 - PREVIOUS INSPECTION NOTES New inspection due to canceled inspection 11/1/2023 - PREVIOUS INSPECTION NOTES 11/1/23: Inspection stopped! Must resolve all deficiencies before scheduling re-inspection. Example: 5ft. head pressure still failed. 10/25/2023 - PREVIOUS INSPECTION NOTES 8/31/2023 - PREVIOUS INSPECTION NOTES 8/29/2023 - PREVIOUS INSPECTION NOTES 7/18/2023 - PREVIOUS INSPECTION NOTES 07-18-2023 1. Second floor window not installed properly. 2. Head test failed. 3. D-4 FB12 & D5 WS04 no moisture barrier installed. 4. Mechanical layout and energy calcs not on site. 5. Wires not phased out. 6. Job site is a mess. Please remove trash prior to next inspection. Inspection stopped. 08-31-2023 1. 3" Plumbing line on first floor not installed as per code. 2319.5 Notching and boring. Please install properly and repair and submit engineering for repaired girder to the building department and have on site for inspection. 2. Energy calcs not approved packet on site. 3. Head test failed. 4. Second floor underlayment not nailed completely. Check all areas. Inspection stopped. 10-25-2023 1. Updated 9-6-2023 electrical plans not on site. 2. Job box and drawings are a mess. Please organize. 3. Head test failed. 4. Second floor underlayment not nailed. Check all See note 4 from 8-31-2023 5. Hole in second floor underlayment closet. 11-13-2023 1. Second floor subflooring not nailed as noted on earlier inspections. 2. Job box is a mess. Please organize. 3. Please submit energy calcs. UFactor and SHGC do not match or need to be a better rating. 4. Shield plates on first floor bath plumbing line need to be installed to the bottom of the floor joists. Inspection stopped. 11-17-2023 1.Energy calcs have been rejected on 11-13-2023 2. Drawings are wet and not readable 3. Approved energy calcs not on site. Inspection stopped. 11-30-2023 1. 11-27 -23 Energy calcs rejected. 2. Approved energy calcs and mechanical layout not on site. Inspection stopped. Inspection stopped. 02-08-2024 1. 1-24-2024 Issue not resolved. Please obtain a revision of energy calcs for ducts on 2nd floor installed, sizes dont match. and above door wall returns calls for 24x4=area of 96 square inches, installed is 6x10=area of 60 square inches. 2. Foil removed from first floor bath CMU wall. 3. Fire foam missed on first and second floor walls. Check all. 4. 2nd floor bedroom window jambs not insulated. Inspection stopped. 02-21-2024 Above issues not resolved. 2. Foil removed from first floor bath CMU wall. 3. Fire foam missed on first and second floor walls. Check all. 4. 2nd floor bedroom window jambs not insulated. 02-22-2024 Above issues not resolved. 2,3,4 1. Insulation missing garage wall. 2. Foil removed from first floor bath CMU wall. 3. Fire foam missed on first and second floor walls. Check all. 4. 2nd floor bedroom window jambs not insulated.
INSULATION 04/02/2024 Disapproved - NO FEE JWALKER
Note: 4/2/24 Multiple water supply pipes and plumbing vent, and drian pipes missing fire blocking at the top plates and floor penetrations. Check all. 3/22/2024 - PREVIOUS INSPECTION NOTES 3/22/24- Walked building with superintedent, has a list of items that need to be addressed before moving forward. (Firestop, fastening of romex, register boots corners mastic, and seal for drywall, etc). Please on reinspect check mechanicals (all rough) and Insulation. 2/22/2024 - PREVIOUS INSPECTION NOTES 2/21/2024 - PREVIOUS INSPECTION NOTES 2/8/2024 - PREVIOUS INSPECTION NOTES Inspector Notes from Inspection 2420 1/24/24- Please obtain a revision of energy calcs for ducts on 2nd floor installed, sizes dont match. and above door wall returns calls for 24x4=area of 96 square inches, installed is 6x10=area of 60 square inches. WILL CHECK AT INSULATION 1/17/2024 - PREVIOUS INSPECTION NOTES 11/30/2023 - PREVIOUS INSPECTION NOTES 11/17/2023 - PREVIOUS INSPECTION NOTES 11/13/2023 - PREVIOUS INSPECTION NOTES New inspection due to canceled inspection 11/1/2023 - PREVIOUS INSPECTION NOTES 11/1/23: Inspection stopped! Must resolve all deficiencies before scheduling re-inspection. Example: 5ft. head pressure still failed. 10/25/2023 - PREVIOUS INSPECTION NOTES 8/31/2023 - PREVIOUS INSPECTION NOTES 8/29/2023 - PREVIOUS INSPECTION NOTES 7/18/2023 - PREVIOUS INSPECTION NOTES 07-18-2023 1. Second floor window not installed properly. 2. Head test failed. 3. D-4 FB12 & D5 WS04 no moisture barrier installed. 4. Mechanical layout and energy calcs not on site. 5. Wires not phased out. 6. Job site is a mess. Please remove trash prior to next inspection. Inspection stopped. 08-31-2023 1. 3" Plumbing line on first floor not installed as per code. 2319.5 Notching and boring. Please install properly and repair and submit engineering for repaired girder to the building department and have on site for inspection. 2. Energy calcs not approved packet on site. 3. Head test failed. 4. Second floor underlayment not nailed completely. Check all areas. Inspection stopped. 10-25-2023 1. Updated 9-6-2023 electrical plans not on site. 2. Job box and drawings are a mess. Please organize. 3. Head test failed. 4. Second floor underlayment not nailed. Check all See note 4 from 8-31-2023 5. Hole in second floor underlayment closet. 11-13-2023 1. Second floor subflooring not nailed as noted on earlier inspections. 2. Job box is a mess. Please organize. 3. Please submit energy calcs. UFactor and SHGC do not match or need to be a better rating. 4. Shield plates on first floor bath plumbing line need to be installed to the bottom of the floor joists. Inspection stopped. 11-17-2023 1.Energy calcs have been rejected on 11-13-2023 2. Drawings are wet and not readable 3. Approved energy calcs not on site. Inspection stopped. 11-30-2023 1. 11-27 -23 Energy calcs rejected. 2. Approved energy calcs and mechanical layout not on site. Inspection stopped. Inspection stopped. 02-08-2024 1. 1-24-2024 Issue not resolved. Please obtain a revision of energy calcs for ducts on 2nd floor installed, sizes dont match. and above door wall returns calls for 24x4=area of 96 square inches, installed is 6x10=area of 60 square inches. 2. Foil removed from first floor bath CMU wall. 3. Fire foam missed on first and second floor walls. Check all. 4. 2nd floor bedroom window jambs not insulated. Inspection stopped. 02-21-2024 Above issues not resolved. 2. Foil removed from first floor bath CMU wall. 3. Fire foam missed on first and second floor walls. Check all. 4. 2nd floor bedroom window jambs not insulated. 02-22-2024 Above issues not resolved. 2,3,4 1. Insulation missing garage wall. 2. Foil removed from first floor bath CMU wall. 3. Fire foam missed on first and second floor walls. Check all. 4. 2nd floor bedroom window jambs not insulated.
INSULATION 03/22/2024 Disapproved - NO FEE JSTEWART
Note: 3/22/24- Walked building with superintedent, has a list of items that need to be addressed before moving forward. (Firestop, fastening of romex, register boots corners mastic, and seal for drywall, etc). Please on reinspect check mechanicals (all rough) and Insulation. 2/22/2024 - PREVIOUS INSPECTION NOTES 2/21/2024 - PREVIOUS INSPECTION NOTES 2/8/2024 - PREVIOUS INSPECTION NOTES Inspector Notes from Inspection 2420 1/24/24- Please obtain a revision of energy calcs for ducts on 2nd floor installed, sizes dont match. and above door wall returns calls for 24x4=area of 96 square inches, installed is 6x10=area of 60 square inches. WILL CHECK AT INSULATION 1/17/2024 - PREVIOUS INSPECTION NOTES 11/30/2023 - PREVIOUS INSPECTION NOTES 11/17/2023 - PREVIOUS INSPECTION NOTES 11/13/2023 - PREVIOUS INSPECTION NOTES New inspection due to canceled inspection 11/1/2023 - PREVIOUS INSPECTION NOTES 11/1/23: Inspection stopped! Must resolve all deficiencies before scheduling re-inspection. Example: 5ft. head pressure still failed. 10/25/2023 - PREVIOUS INSPECTION NOTES 8/31/2023 - PREVIOUS INSPECTION NOTES 8/29/2023 - PREVIOUS INSPECTION NOTES 7/18/2023 - PREVIOUS INSPECTION NOTES 07-18-2023 1. Second floor window not installed properly. 2. Head test failed. 3. D-4 FB12 & D5 WS04 no moisture barrier installed. 4. Mechanical layout and energy calcs not on site. 5. Wires not phased out. 6. Job site is a mess. Please remove trash prior to next inspection. Inspection stopped. 08-31-2023 1. 3" Plumbing line on first floor not installed as per code. 2319.5 Notching and boring. Please install properly and repair and submit engineering for repaired girder to the building department and have on site for inspection. 2. Energy calcs not approved packet on site. 3. Head test failed. 4. Second floor underlayment not nailed completely. Check all areas. Inspection stopped. 10-25-2023 1. Updated 9-6-2023 electrical plans not on site. 2. Job box and drawings are a mess. Please organize. 3. Head test failed. 4. Second floor underlayment not nailed. Check all See note 4 from 8-31-2023 5. Hole in second floor underlayment closet. 11-13-2023 1. Second floor subflooring not nailed as noted on earlier inspections. 2. Job box is a mess. Please organize. 3. Please submit energy calcs. UFactor and SHGC do not match or need to be a better rating. 4. Shield plates on first floor bath plumbing line need to be installed to the bottom of the floor joists. Inspection stopped. 11-17-2023 1.Energy calcs have been rejected on 11-13-2023 2. Drawings are wet and not readable 3. Approved energy calcs not on site. Inspection stopped. 11-30-2023 1. 11-27 -23 Energy calcs rejected. 2. Approved energy calcs and mechanical layout not on site. Inspection stopped. Inspection stopped. 02-08-2024 1. 1-24-2024 Issue not resolved. Please obtain a revision of energy calcs for ducts on 2nd floor installed, sizes dont match. and above door wall returns calls for 24x4=area of 96 square inches, installed is 6x10=area of 60 square inches. 2. Foil removed from first floor bath CMU wall. 3. Fire foam missed on first and second floor walls. Check all. 4. 2nd floor bedroom window jambs not insulated. Inspection stopped. 02-21-2024 Above issues not resolved. 2. Foil removed from first floor bath CMU wall. 3. Fire foam missed on first and second floor walls. Check all. 4. 2nd floor bedroom window jambs not insulated. 02-22-2024 Above issues not resolved. 2,3,4 1. Insulation missing garage wall. 2. Foil removed from first floor bath CMU wall. 3. Fire foam missed on first and second floor walls. Check all. 4. 2nd floor bedroom window jambs not insulated.
INSULATION 02/22/2024 Disapproved -FEE REQUIRED AGAETANO
Note: 2/21/2024 - PREVIOUS INSPECTION NOTES 2/8/2024 - PREVIOUS INSPECTION NOTES Inspector Notes from Inspection 2420 1/24/24- Please obtain a revision of energy calcs for ducts on 2nd floor installed, sizes dont match. and above door wall returns calls for 24x4=area of 96 square inches, installed is 6x10=area of 60 square inches. WILL CHECK AT INSULATION 1/17/2024 - PREVIOUS INSPECTION NOTES 11/30/2023 - PREVIOUS INSPECTION NOTES 11/17/2023 - PREVIOUS INSPECTION NOTES 11/13/2023 - PREVIOUS INSPECTION NOTES New inspection due to canceled inspection 11/1/2023 - PREVIOUS INSPECTION NOTES 11/1/23: Inspection stopped! Must resolve all deficiencies before scheduling re-inspection. Example: 5ft. head pressure still failed. 10/25/2023 - PREVIOUS INSPECTION NOTES 8/31/2023 - PREVIOUS INSPECTION NOTES 8/29/2023 - PREVIOUS INSPECTION NOTES 7/18/2023 - PREVIOUS INSPECTION NOTES 07-18-2023 1. Second floor window not installed properly. 2. Head test failed. 3. D-4 FB12 & D5 WS04 no moisture barrier installed. 4. Mechanical layout and energy calcs not on site. 5. Wires not phased out. 6. Job site is a mess. Please remove trash prior to next inspection. Inspection stopped. 08-31-2023 1. 3" Plumbing line on first floor not installed as per code. 2319.5 Notching and boring. Please install properly and repair and submit engineering for repaired girder to the building department and have on site for inspection. 2. Energy calcs not approved packet on site. 3. Head test failed. 4. Second floor underlayment not nailed completely. Check all areas. Inspection stopped. 10-25-2023 1. Updated 9-6-2023 electrical plans not on site. 2. Job box and drawings are a mess. Please organize. 3. Head test failed. 4. Second floor underlayment not nailed. Check all See note 4 from 8-31-2023 5. Hole in second floor underlayment closet. 11-13-2023 1. Second floor subflooring not nailed as noted on earlier inspections. 2. Job box is a mess. Please organize. 3. Please submit energy calcs. UFactor and SHGC do not match or need to be a better rating. 4. Shield plates on first floor bath plumbing line need to be installed to the bottom of the floor joists. Inspection stopped. 11-17-2023 1.Energy calcs have been rejected on 11-13-2023 2. Drawings are wet and not readable 3. Approved energy calcs not on site. Inspection stopped. 11-30-2023 1. 11-27 -23 Energy calcs rejected. 2. Approved energy calcs and mechanical layout not on site. Inspection stopped. Inspection stopped. 02-08-2024 1. 1-24-2024 Issue not resolved. Please obtain a revision of energy calcs for ducts on 2nd floor installed, sizes dont match. and above door wall returns calls for 24x4=area of 96 square inches, installed is 6x10=area of 60 square inches. 2. Foil removed from first floor bath CMU wall. 3. Fire foam missed on first and second floor walls. Check all. 4. 2nd floor bedroom window jambs not insulated. Inspection stopped. 02-21-2024 Above issues not resolved. 2. Foil removed from first floor bath CMU wall. 3. Fire foam missed on first and second floor walls. Check all. 4. 2nd floor bedroom window jambs not insulated. 02-22-2024 Above issues not resolved. 2,3,4 1. Insulation missing garage wall. 2. Foil removed from first floor bath CMU wall. 3. Fire foam missed on first and second floor walls. Check all. 4. 2nd floor bedroom window jambs not insulated. 5. Please remove trash prior to next inspection. Empty dumpster on site.
INSULATION 02/21/2024 Disapproved -FEE REQUIRED AGAETANO
Note: 2/8/2024 - PREVIOUS INSPECTION NOTES Inspector Notes from Inspection 2420 1/24/24- Please obtain a revision of energy calcs for ducts on 2nd floor installed, sizes dont match. and above door wall returns calls for 24x4=area of 96 square inches, installed is 6x10=area of 60 square inches. WILL CHECK AT INSULATION 1/17/2024 - PREVIOUS INSPECTION NOTES 11/30/2023 - PREVIOUS INSPECTION NOTES 11/17/2023 - PREVIOUS INSPECTION NOTES 11/13/2023 - PREVIOUS INSPECTION NOTES New inspection due to canceled inspection 11/1/2023 - PREVIOUS INSPECTION NOTES 11/1/23: Inspection stopped! Must resolve all deficiencies before scheduling re-inspection. Example: 5ft. head pressure still failed. 10/25/2023 - PREVIOUS INSPECTION NOTES 8/31/2023 - PREVIOUS INSPECTION NOTES 8/29/2023 - PREVIOUS INSPECTION NOTES 7/18/2023 - PREVIOUS INSPECTION NOTES 07-18-2023 1. Second floor window not installed properly. 2. Head test failed. 3. D-4 FB12 & D5 WS04 no moisture barrier installed. 4. Mechanical layout and energy calcs not on site. 5. Wires not phased out. 6. Job site is a mess. Please remove trash prior to next inspection. Inspection stopped. 08-31-2023 1. 3" Plumbing line on first floor not installed as per code. 2319.5 Notching and boring. Please install properly and repair and submit engineering for repaired girder to the building department and have on site for inspection. 2. Energy calcs not approved packet on site. 3. Head test failed. 4. Second floor underlayment not nailed completely. Check all areas. Inspection stopped. 10-25-2023 1. Updated 9-6-2023 electrical plans not on site. 2. Job box and drawings are a mess. Please organize. 3. Head test failed. 4. Second floor underlayment not nailed. Check all See note 4 from 8-31-2023 5. Hole in second floor underlayment closet. 11-13-2023 1. Second floor subflooring not nailed as noted on earlier inspections. 2. Job box is a mess. Please organize. 3. Please submit energy calcs. UFactor and SHGC do not match or need to be a better rating. 4. Shield plates on first floor bath plumbing line need to be installed to the bottom of the floor joists. Inspection stopped. 11-17-2023 1.Energy calcs have been rejected on 11-13-2023 2. Drawings are wet and not readable 3. Approved energy calcs not on site. Inspection stopped. 11-30-2023 1. 11-27 -23 Energy calcs rejected. 2. Approved energy calcs and mechanical layout not on site. Inspection stopped. Inspection stopped. 02-08-2024 1. 1-24-2024 Issue not resolved. Please obtain a revision of energy calcs for ducts on 2nd floor installed, sizes dont match. and above door wall returns calls for 24x4=area of 96 square inches, installed is 6x10=area of 60 square inches. 2. Foil removed from first floor bath CMU wall. 3. Fire foam missed on first and second floor walls. Check all. 4. 2nd floor bedroom window jambs not insulated. Inspection stopped. 02-21-2024 Above issues not resolved. 2. Foil removed from first floor bath CMU wall. 3. Fire foam missed on first and second floor walls. Check all. 4. 2nd floor bedroom window jambs not insulated.
INSULATION 02/08/2024 Disapproved -FEE REQUIRED AGAETANO
Note: Inspector Notes from Inspection 2420 1/24/24- Please obtain a revision of energy calcs for ducts on 2nd floor installed, sizes dont match. and above door wall returns calls for 24x4=area of 96 square inches, installed is 6x10=area of 60 square inches. WILL CHECK AT INSULATION 1/17/2024 - PREVIOUS INSPECTION NOTES 11/30/2023 - PREVIOUS INSPECTION NOTES 11/17/2023 - PREVIOUS INSPECTION NOTES 11/13/2023 - PREVIOUS INSPECTION NOTES New inspection due to canceled inspection 11/1/2023 - PREVIOUS INSPECTION NOTES 11/1/23: Inspection stopped! Must resolve all deficiencies before scheduling re-inspection. Example: 5ft. head pressure still failed. 10/25/2023 - PREVIOUS INSPECTION NOTES 8/31/2023 - PREVIOUS INSPECTION NOTES 8/29/2023 - PREVIOUS INSPECTION NOTES 7/18/2023 - PREVIOUS INSPECTION NOTES 07-18-2023 1. Second floor window not installed properly. 2. Head test failed. 3. D-4 FB12 & D5 WS04 no moisture barrier installed. 4. Mechanical layout and energy calcs not on site. 5. Wires not phased out. 6. Job site is a mess. Please remove trash prior to next inspection. Inspection stopped. 08-31-2023 1. 3" Plumbing line on first floor not installed as per code. 2319.5 Notching and boring. Please install properly and repair and submit engineering for repaired girder to the building department and have on site for inspection. 2. Energy calcs not approved packet on site. 3. Head test failed. 4. Second floor underlayment not nailed completely. Check all areas. Inspection stopped. 10-25-2023 1. Updated 9-6-2023 electrical plans not on site. 2. Job box and drawings are a mess. Please organize. 3. Head test failed. 4. Second floor underlayment not nailed. Check all See note 4 from 8-31-2023 5. Hole in second floor underlayment closet. 11-13-2023 1. Second floor subflooring not nailed as noted on earlier inspections. 2. Job box is a mess. Please organize. 3. Please submit energy calcs. UFactor and SHGC do not match or need to be a better rating. 4. Shield plates on first floor bath plumbing line need to be installed to the bottom of the floor joists. Inspection stopped. 11-17-2023 1.Energy calcs have been rejected on 11-13-2023 2. Drawings are wet and not readable 3. Approved energy calcs not on site. Inspection stopped. 11-30-2023 1. 11-27 -23 Energy calcs rejected. 2. Approved energy calcs and mechanical layout not on site. Inspection stopped. Inspection stopped. 02-08-2024 1. 1-24-2024 Issue not resolved. Please obtain a revision of energy calcs for ducts on 2nd floor installed, sizes dont match. and above door wall returns calls for 24x4=area of 96 square inches, installed is 6x10=area of 60 square inches. 2. Foil removed from first floor bath CMU wall. 3. Fire foam missed on first and second floor walls. Check all. 4. 2nd floor bedroom window jambs not insulated. Inspection stopped.
ALL ROUGH 01/24/2024 APPROVED - AS NOTED JSTEWART
Note: 1/24/24- Please obtain a revision of energy calcs for ducts on 2nd floor installed, sizes dont match. and above door wall returns calls for 24x4=area of 96 square inches, installed is 6x10=area of 60 square inches. WILL CHECK AT INSULATION 1/17/2024 - PREVIOUS INSPECTION NOTES 11/30/2023 - PREVIOUS INSPECTION NOTES 11/17/2023 - PREVIOUS INSPECTION NOTES 11/13/2023 - PREVIOUS INSPECTION NOTES New inspection due to canceled inspection 11/1/2023 - PREVIOUS INSPECTION NOTES 11/1/23: Inspection stopped! Must resolve all deficiencies before scheduling re-inspection. Example: 5ft. head pressure still failed. 10/25/2023 - PREVIOUS INSPECTION NOTES 8/31/2023 - PREVIOUS INSPECTION NOTES 8/29/2023 - PREVIOUS INSPECTION NOTES 7/18/2023 - PREVIOUS INSPECTION NOTES 07-18-2023 1. Second floor window not installed properly. 2. Head test failed. 3. D-4 FB12 & D5 WS04 no moisture barrier installed. 4. Mechanical layout and energy calcs not on site. 5. Wires not phased out. 6. Job site is a mess. Please remove trash prior to next inspection. Inspection stopped. 08-31-2023 1. 3" Plumbing line on first floor not installed as per code. 2319.5 Notching and boring. Please install properly and repair and submit engineering for repaired girder to the building department and have on site for inspection. 2. Energy calcs not approved packet on site. 3. Head test failed. 4. Second floor underlayment not nailed completely. Check all areas. Inspection stopped. 10-25-2023 1. Updated 9-6-2023 electrical plans not on site. 2. Job box and drawings are a mess. Please organize. 3. Head test failed. 4. Second floor underlayment not nailed. Check all See note 4 from 8-31-2023 5. Hole in second floor underlayment closet. 11-13-2023 1. Second floor subflooring not nailed as noted on earlier inspections. 2. Job box is a mess. Please organize. 3. Please submit energy calcs. UFactor and SHGC do not match or need to be a better rating. 4. Shield plates on first floor bath plumbing line need to be installed to the bottom of the floor joists. Inspection stopped. 11-17-2023 1.Energy calcs have been rejected on 11-13-2023 2. Drawings are wet and not readable 3. Approved energy calcs not on site. Inspection stopped. 11-30-2023 1. 11-27 -23 Energy calcs rejected. 2. Approved energy calcs and mechanical layout not on site. Inspection stopped. Inspection stopped.
ALL ROUGH 01/17/2024 CANCELLED BY APPLICANT AGAETANO
Note: 11/30/2023 - PREVIOUS INSPECTION NOTES 11/17/2023 - PREVIOUS INSPECTION NOTES 11/13/2023 - PREVIOUS INSPECTION NOTES New inspection due to canceled inspection 11/1/2023 - PREVIOUS INSPECTION NOTES 11/1/23: Inspection stopped! Must resolve all deficiencies before scheduling re-inspection. Example: 5ft. head pressure still failed. 10/25/2023 - PREVIOUS INSPECTION NOTES 8/31/2023 - PREVIOUS INSPECTION NOTES 8/29/2023 - PREVIOUS INSPECTION NOTES 7/18/2023 - PREVIOUS INSPECTION NOTES 07-18-2023 1. Second floor window not installed properly. 2. Head test failed. 3. D-4 FB12 & D5 WS04 no moisture barrier installed. 4. Mechanical layout and energy calcs not on site. 5. Wires not phased out. 6. Job site is a mess. Please remove trash prior to next inspection. Inspection stopped. 08-31-2023 1. 3" Plumbing line on first floor not installed as per code. 2319.5 Notching and boring. Please install properly and repair and submit engineering for repaired girder to the building department and have on site for inspection. 2. Energy calcs not approved packet on site. 3. Head test failed. 4. Second floor underlayment not nailed completely. Check all areas. Inspection stopped. 10-25-2023 1. Updated 9-6-2023 electrical plans not on site. 2. Job box and drawings are a mess. Please organize. 3. Head test failed. 4. Second floor underlayment not nailed. Check all See note 4 from 8-31-2023 5. Hole in second floor underlayment closet. 11-13-2023 1. Second floor subflooring not nailed as noted on earlier inspections. 2. Job box is a mess. Please organize. 3. Please submit energy calcs. UFactor and SHGC do not match or need to be a better rating. 4. Shield plates on first floor bath plumbing line need to be installed to the bottom of the floor joists. Inspection stopped. 11-17-2023 1.Energy calcs have been rejected on 11-13-2023 2. Drawings are wet and not readable 3. Approved energy calcs not on site. Inspection stopped. 11-30-2023 1. 11-27 -23 Energy calcs rejected. 2. Approved energy calcs and mechanical layout not on site. Inspection stopped. Inspection stopped.
ALL ROUGH 11/30/2023 Disapproved -FEE REQUIRED AGAETANO
Note: 11/17/2023 - PREVIOUS INSPECTION NOTES 11/13/2023 - PREVIOUS INSPECTION NOTES New inspection due to canceled inspection 11/1/2023 - PREVIOUS INSPECTION NOTES 11/1/23: Inspection stopped! Must resolve all deficiencies before scheduling re-inspection. Example: 5ft. head pressure still failed. 10/25/2023 - PREVIOUS INSPECTION NOTES 8/31/2023 - PREVIOUS INSPECTION NOTES 8/29/2023 - PREVIOUS INSPECTION NOTES 7/18/2023 - PREVIOUS INSPECTION NOTES 07-18-2023 1. Second floor window not installed properly. 2. Head test failed. 3. D-4 FB12 & D5 WS04 no moisture barrier installed. 4. Mechanical layout and energy calcs not on site. 5. Wires not phased out. 6. Job site is a mess. Please remove trash prior to next inspection. Inspection stopped. 08-31-2023 1. 3" Plumbing line on first floor not installed as per code. 2319.5 Notching and boring. Please install properly and repair and submit engineering for repaired girder to the building department and have on site for inspection. 2. Energy calcs not approved packet on site. 3. Head test failed. 4. Second floor underlayment not nailed completely. Check all areas. Inspection stopped. 10-25-2023 1. Updated 9-6-2023 electrical plans not on site. 2. Job box and drawings are a mess. Please organize. 3. Head test failed. 4. Second floor underlayment not nailed. Check all See note 4 from 8-31-2023 5. Hole in second floor underlayment closet. 11-13-2023 1. Second floor subflooring not nailed as noted on earlier inspections. 2. Job box is a mess. Please organize. 3. Please submit energy calcs. UFactor and SHGC do not match or need to be a better rating. 4. Shield plates on first floor bath plumbing line need to be installed to the bottom of the floor joists. Inspection stopped. 11-17-2023 1.Energy calcs have been rejected on 11-13-2023 2. Drawings are wet and not readable 3. Approved energy calcs not on site. Inspection stopped. 11-30-2023 1. 11-27 -23 Energy calcs rejected. 2. Approved energy calcs and mechanical layout not on site. Inspection stopped. Inspection stopped.
ALL ROUGH 11/17/2023 Disapproved -FEE REQUIRED AGAETANO
Note: 11/13/2023 - PREVIOUS INSPECTION NOTES New inspection due to canceled inspection 11/1/2023 - PREVIOUS INSPECTION NOTES 11/1/23: Inspection stopped! Must resolve all deficiencies before scheduling re-inspection. Example: 5ft. head pressure still failed. 10/25/2023 - PREVIOUS INSPECTION NOTES 8/31/2023 - PREVIOUS INSPECTION NOTES 8/29/2023 - PREVIOUS INSPECTION NOTES 7/18/2023 - PREVIOUS INSPECTION NOTES 07-18-2023 1. Second floor window not installed properly. 2. Head test failed. 3. D-4 FB12 & D5 WS04 no moisture barrier installed. 4. Mechanical layout and energy calcs not on site. 5. Wires not phased out. 6. Job site is a mess. Please remove trash prior to next inspection. Inspection stopped. 08-31-2023 1. 3" Plumbing line on first floor not installed as per code. 2319.5 Notching and boring. Please install properly and repair and submit engineering for repaired girder to the building department and have on site for inspection. 2. Energy calcs not approved packet on site. 3. Head test failed. 4. Second floor underlayment not nailed completely. Check all areas. Inspection stopped. 10-25-2023 1. Updated 9-6-2023 electrical plans not on site. 2. Job box and drawings are a mess. Please organize. 3. Head test failed. 4. Second floor underlayment not nailed. Check all See note 4 from 8-31-2023 5. Hole in second floor underlayment closet. 11-13-2023 1. Second floor subflooring not nailed as noted on earlier inspections. 2. Job box is a mess. Please organize. 3. Please submit energy calcs. UFactor and SHGC do not match or need to be a better rating. 4. Shield plates on first floor bath plumbing line need to be installed to the bottom of the floor joists. Inspection stopped. 11-17-2023 1.Energy calcs have been rejected on 11-13-2023 2. Drawings are wet and not readable 3. Approved energy calcs not on site. Inspection stopped.
ALL ROUGH 11/13/2023 CANCELLED BY APPLICANT WEB
Note: 11/1/2023 - PREVIOUS INSPECTION NOTES 11/1/23: Inspection stopped! Must resolve all deficiencies before scheduling re-inspection. Example: 5ft. head pressure still failed. 10/25/2023 - PREVIOUS INSPECTION NOTES 8/31/2023 - PREVIOUS INSPECTION NOTES 8/29/2023 - PREVIOUS INSPECTION NOTES 7/18/2023 - PREVIOUS INSPECTION NOTES 07-18-2023 1. Second floor window not installed properly. 2. Head test failed. 3. D-4 FB12 & D5 WS04 no moisture barrier installed. 4. Mechanical layout and energy calcs not on site. 5. Wires not phased out. 6. Job site is a mess. Please remove trash prior to next inspection. Inspection stopped. 08-31-2023 1. 3" Plumbing line on first floor not installed as per code. 2319.5 Notching and boring. Please install properly and repair and submit engineering for repaired girder to the building department and have on site for inspection. 2. Energy calcs not approved packet on site. 3. Head test failed. 4. Second floor underlayment not nailed completely. Check all areas. Inspection stopped. 10-25-2023 1. Updated 9-6-2023 electrical plans not on site. 2. Job box and drawings are a mess. Please organize. 3. Head test failed. 4. Second floor underlayment not nailed. Check all See note 4 from 8-31-2023 5. Hole in second floor underlayment closet.
ALL ROUGH 11/13/2023 Disapproved -FEE REQUIRED AGAETANO
Note: New inspection due to canceled inspection 11/1/2023 - PREVIOUS INSPECTION NOTES 11/1/23: Inspection stopped! Must resolve all deficiencies before scheduling re-inspection. Example: 5ft. head pressure still failed. 10/25/2023 - PREVIOUS INSPECTION NOTES 8/31/2023 - PREVIOUS INSPECTION NOTES 8/29/2023 - PREVIOUS INSPECTION NOTES 7/18/2023 - PREVIOUS INSPECTION NOTES 07-18-2023 1. Second floor window not installed properly. 2. Head test failed. 3. D-4 FB12 & D5 WS04 no moisture barrier installed. 4. Mechanical layout and energy calcs not on site. 5. Wires not phased out. 6. Job site is a mess. Please remove trash prior to next inspection. Inspection stopped. 08-31-2023 1. 3" Plumbing line on first floor not installed as per code. 2319.5 Notching and boring. Please install properly and repair and submit engineering for repaired girder to the building department and have on site for inspection. 2. Energy calcs not approved packet on site. 3. Head test failed. 4. Second floor underlayment not nailed completely. Check all areas. Inspection stopped. 10-25-2023 1. Updated 9-6-2023 electrical plans not on site. 2. Job box and drawings are a mess. Please organize. 3. Head test failed. 4. Second floor underlayment not nailed. Check all See note 4 from 8-31-2023 5. Hole in second floor underlayment closet. 11-13-2023 1. Second floor subflooring not nailed as noted on earlier inspections. 2. Job box is a mess. Please organize. 3. Please submit energy calcs. UFactor and SHGC do not match or need to be a better rating. 4. Shield plates on first floor bath plumbing line need to be installed to the bottom of the floor joists. Inspection stopped.
ALL ROUGH 11/01/2023 Disapproved -FEE REQUIRED RSIMS
Note: 11/1/23: Inspection stopped! Must resolve all deficiencies before scheduling re-inspection. Example: 5ft. head pressure still failed. 10/25/2023 - PREVIOUS INSPECTION NOTES 8/31/2023 - PREVIOUS INSPECTION NOTES 8/29/2023 - PREVIOUS INSPECTION NOTES 7/18/2023 - PREVIOUS INSPECTION NOTES 07-18-2023 1. Second floor window not installed properly. 2. Head test failed. 3. D-4 FB12 & D5 WS04 no moisture barrier installed. 4. Mechanical layout and energy calcs not on site. 5. Wires not phased out. 6. Job site is a mess. Please remove trash prior to next inspection. Inspection stopped. 08-31-2023 1. 3" Plumbing line on first floor not installed as per code. 2319.5 Notching and boring. Please install properly and repair and submit engineering for repaired girder to the building department and have on site for inspection. 2. Energy calcs not approved packet on site. 3. Head test failed. 4. Second floor underlayment not nailed completely. Check all areas. Inspection stopped. 10-25-2023 1. Updated 9-6-2023 electrical plans not on site. 2. Job box and drawings are a mess. Please organize. 3. Head test failed. 4. Second floor underlayment not nailed. Check all See note 4 from 8-31-2023 5. Hole in second floor underlayment closet.
ALL ROUGH 10/25/2023 Disapproved -FEE REQUIRED AGAETANO
Note: 8/31/2023 - PREVIOUS INSPECTION NOTES 8/29/2023 - PREVIOUS INSPECTION NOTES 7/18/2023 - PREVIOUS INSPECTION NOTES 07-18-2023 1. Second floor window not installed properly. 2. Head test failed. 3. D-4 FB12 & D5 WS04 no moisture barrier installed. 4. Mechanical layout and energy calcs not on site. 5. Wires not phased out. 6. Job site is a mess. Please remove trash prior to next inspection. Inspection stopped. 08-31-2023 1. 3" Plumbing line on first floor not installed as per code. 2319.5 Notching and boring. Please install properly and repair and submit engineering for repaired girder to the building department and have on site for inspection. 2. Energy calcs not approved packet on site. 3. Head test failed. 4. Second floor underlayment not nailed completely. Check all areas. Inspection stopped. 10-25-2023 1. Updated 9-6-2023 electrical plans not on site. 2. Job box and drawings are a mess. Please organize. 3. Head test failed. 4. Second floor underlayment not nailed. Check all See note 4 from 8-31-2023 5. Hole in second floor underlayment closet.
LATH/BRICK/ WATER BARRIER 09/06/2023 APPROVED AGAETANO
Note: 8/4/2023 - PREVIOUS INSPECTION NOTES 8-4-23 1. Not ready.
ALL ROUGH 08/31/2023 Disapproved -FEE REQUIRED AGAETANO
Note: 8/29/2023 - PREVIOUS INSPECTION NOTES 7/18/2023 - PREVIOUS INSPECTION NOTES 07-18-2023 1. Second floor window not installed properly. 2. Head test failed. 3. D-4 FB12 & D5 WS04 no moisture barrier installed. 4. Mechanical layout and energy calcs not on site. 5. Wires not phased out. 6. Job site is a mess. Please remove trash prior to next inspection. Inspection stopped. 08-31-2023 1. 3" Plumbing line on first floor not installed as per code. 2319.5 Notching and boring. Please install properly and repair and submit engineering for repaired girder to the building department and have on site for inspection. 2. Energy calcs not approved packet on site. 3. Head test failed. 4. Second floor underlayment not nailed completely. Check all areas. 5. Please remove high grass and weeds at job box for access. Inspection stopped.
ALL ROUGH 08/29/2023 CANCELLED BY APPLICANT AGAETANO
Note: 7/18/2023 - PREVIOUS INSPECTION NOTES 07-18-2023 1. Second floor window not installed properly. 2. Head test failed. 3. D-4 FB12 & D5 WS04 no moisture barrier installed. 4. Mechanical layout and energy calcs not on site. 5. Wires not phased out. 6. Job site is a mess. Please remove trash prior to next inspection. Inspectiom stopped.
ELECTRIC - EARLY POWER 08/11/2023 Disapproved - NO FEE AGAETANO
Note: 08-11-2023 Devices and outlets not installed, no drywall, electrical panel not complete.
LATH/BRICK/ WATER BARRIER 08/04/2023 Disapproved - NO FEE BTAYLOR
Note: 8-4-23 1. Not ready.
ALL ROUGH 07/18/2023 Disapproved -FEE REQUIRED AGAETANO
Note: 07-18-2023 1. Second floor window not installed properly. 2. Head test failed. 3. D-4 FB12 & D5 WS04 no moisture barrier installed. 4. Mechanical layout and energy calcs not on site. 5. Wires not phased out. 6. Job site is a mess. Please remove trash prior to next inspection. Inspectiom stopped.
ROOF VALLEY & METAL 07/14/2023 APPROVED TSTAUFFACHER
ROOF SHEATHING / BRACES/TIES/DOWN CELL 07/07/2023 APPROVED FWILLIS
Note: 7/5/2023 - PREVIOUS INSPECTION NOTES 7-5-23 Same notres as prior inspection 1. Multiple details not followed in plans. 2. Need second story structural page. circled on plans. (please check and correct all deatils prior to next inspection) engineering has not been checked. 6/27/2023 - PREVIOUS INSPECTION NOTES Inspector Notes from Inspection 2340 6/5/2023 - PREVIOUS INSPECTION NOTES 6/2/2023 - PREVIOUS INSPECTION NOTES 5/30/2023 - PREVIOUS INSPECTION NOTES 05-30-2023 1. NEED APPROVED DOCUMENTS ON SITE FOR INSPECTION SITE 107.3,1 2. [F] 501.2 Address identification. New and existing buildings shall be provided with approved address identification. The address identification shall be legible and placed in a position that is visible from the street or road fronting the property. Address identification characters shall contrast with their background. Address numbers shall be Arabic numbers or alphabetical letters. Numbers shall not be spelled out. Each character shall be a minimum of 4 inches (102 mm) high with a minimum stroke width of 1/2 inch (12.7 mm). Where required by the fire code official, address identification shall be provided in additional approved locations to facilitate emergency response. Where access is by means of a private road and the building address cannot be viewed from the public way, a monument, pole or other approved sign or means shall be used to identify the structure. Address identification shall be maintained. 06-02-2023 8 1/2" X 11 drawings are too small to read. Please have a full set of approved readable drawings on site for all inspections. 06-05-2023 Please see 06-02-2023 Notes. 8 1/2" X 11 drawings are too small to read. Please have a full set of approved readable drawings on site for all inspections. 06-06-2023 Back left lintel is damaged. Please provide engineering concerning the back left lintel is structually sound or install new lintel. Remove soil from right side cell. 6-27-23 1. Multiple details not followed in plans. 2. Need second story structural page. circled on plans. engineering has not been checked.
ROOF SHEATHING 07/07/2023 APPROVED FWILLIS
ELECTRIC-TUG 07/05/2023 APPROVED LMILLER
Note: 6/29/2023 - PREVIOUS INSPECTION NOTES 06-29-2023 Wires need to be protected from ground. NEC 230.50
ELECTRIC - EARLY POWER 07/05/2023 CANCELLED BY APPLICANT WEB
ROOF SHEATHING / BRACES/TIES/DOWN CELL 07/05/2023 Disapproved -FEE REQUIRED LMILLER
Note: 7-5-23 Same notres as prior inspection 1. Multiple details not followed in plans. 2. Need second story structural page. circled on plans. (please check and correct all deatils prior to next inspection) engineering has not been checked. 6/27/2023 - PREVIOUS INSPECTION NOTES Inspector Notes from Inspection 2340 6/5/2023 - PREVIOUS INSPECTION NOTES 6/2/2023 - PREVIOUS INSPECTION NOTES 5/30/2023 - PREVIOUS INSPECTION NOTES 05-30-2023 1. NEED APPROVED DOCUMENTS ON SITE FOR INSPECTION SITE 107.3,1 2. [F] 501.2 Address identification. New and existing buildings shall be provided with approved address identification. The address identification shall be legible and placed in a position that is visible from the street or road fronting the property. Address identification characters shall contrast with their background. Address numbers shall be Arabic numbers or alphabetical letters. Numbers shall not be spelled out. Each character shall be a minimum of 4 inches (102 mm) high with a minimum stroke width of 1/2 inch (12.7 mm). Where required by the fire code official, address identification shall be provided in additional approved locations to facilitate emergency response. Where access is by means of a private road and the building address cannot be viewed from the public way, a monument, pole or other approved sign or means shall be used to identify the structure. Address identification shall be maintained. 06-02-2023 8 1/2" X 11 drawings are too small to read. Please have a full set of approved readable drawings on site for all inspections. 06-05-2023 Please see 06-02-2023 Notes. 8 1/2" X 11 drawings are too small to read. Please have a full set of approved readable drawings on site for all inspections. 06-06-2023 Back left lintel is damaged. Please provide engineering concerning the back left lintel is structually sound or install new lintel. Remove soil from right side cell. 6-27-23 1. Multiple details not followed in plans. 2. Need second story structural page. circled on plans. engineering has not been checked.
ELECTRIC-TUG 06/29/2023 Disapproved - NO FEE AGAETANO
Note: 06-29-2023 Wires need to be protected from ground. NEC 230.50. NEC 300.5 Underground Installations.
ELECTRIC - EARLY POWER 06/29/2023 CANCELLED BY APPLICANT WEB
WALL SHEATHING 06/27/2023 APPROVED BTAYLOR
Note: Inspector Notes from Inspection 2340 6/5/2023 - PREVIOUS INSPECTION NOTES 6/2/2023 - PREVIOUS INSPECTION NOTES 5/30/2023 - PREVIOUS INSPECTION NOTES 05-30-2023 1. NEED APPROVED DOCUMENTS ON SITE FOR INSPECTION SITE 107.3,1 2. [F] 501.2 Address identification. New and existing buildings shall be provided with approved address identification. The address identification shall be legible and placed in a position that is visible from the street or road fronting the property. Address identification characters shall contrast with their background. Address numbers shall be Arabic numbers or alphabetical letters. Numbers shall not be spelled out. Each character shall be a minimum of 4 inches (102 mm) high with a minimum stroke width of 1/2 inch (12.7 mm). Where required by the fire code official, address identification shall be provided in additional approved locations to facilitate emergency response. Where access is by means of a private road and the building address cannot be viewed from the public way, a monument, pole or other approved sign or means shall be used to identify the structure. Address identification shall be maintained. 06-02-2023 8 1/2" X 11 drawings are too small to read. Please have a full set of approved readable drawings on site for all inspections. 06-05-2023 Please see 06-02-2023 Notes. 8 1/2" X 11 drawings are too small to read. Please have a full set of approved readable drawings on site for all inspections. 06-06-2023 Back left lintel is damaged. Please provide engineering concerning the back left lintel is structually sound or install new lintel. Remove soil from right side cell.
ROOF SHEATHING / BRACES/TIES/DOWN CELL 06/27/2023 Disapproved - NO FEE BTAYLOR
Note: Inspector Notes from Inspection 2340 6/5/2023 - PREVIOUS INSPECTION NOTES 6/2/2023 - PREVIOUS INSPECTION NOTES 5/30/2023 - PREVIOUS INSPECTION NOTES 05-30-2023 1. NEED APPROVED DOCUMENTS ON SITE FOR INSPECTION SITE 107.3,1 2. [F] 501.2 Address identification. New and existing buildings shall be provided with approved address identification. The address identification shall be legible and placed in a position that is visible from the street or road fronting the property. Address identification characters shall contrast with their background. Address numbers shall be Arabic numbers or alphabetical letters. Numbers shall not be spelled out. Each character shall be a minimum of 4 inches (102 mm) high with a minimum stroke width of 1/2 inch (12.7 mm). Where required by the fire code official, address identification shall be provided in additional approved locations to facilitate emergency response. Where access is by means of a private road and the building address cannot be viewed from the public way, a monument, pole or other approved sign or means shall be used to identify the structure. Address identification shall be maintained. 06-02-2023 8 1/2" X 11 drawings are too small to read. Please have a full set of approved readable drawings on site for all inspections. 06-05-2023 Please see 06-02-2023 Notes. 8 1/2" X 11 drawings are too small to read. Please have a full set of approved readable drawings on site for all inspections. 06-06-2023 Back left lintel is damaged. Please provide engineering concerning the back left lintel is structually sound or install new lintel. Remove soil from right side cell. 6-27-23 1. Multiple details not followed in plans. 2. Need second story structural page. circled on plans. engineering has not been checked.
FOUND SURVEY APPROVED (OFFICE) 06/26/2023 APPROVED AMOBLEY
TIE BEAM / LINTEL 06/06/2023 APPROVED - AS NOTED AGAETANO
Note: 6/5/2023 - PREVIOUS INSPECTION NOTES 6/2/2023 - PREVIOUS INSPECTION NOTES 5/30/2023 - PREVIOUS INSPECTION NOTES 05-30-2023 1. NEED APPROVED DOCUMENTS ON SITE FOR INSPECTION SITE 107.3,1 2. [F] 501.2 Address identification. New and existing buildings shall be provided with approved address identification. The address identification shall be legible and placed in a position that is visible from the street or road fronting the property. Address identification characters shall contrast with their background. Address numbers shall be Arabic numbers or alphabetical letters. Numbers shall not be spelled out. Each character shall be a minimum of 4 inches (102 mm) high with a minimum stroke width of 1/2 inch (12.7 mm). Where required by the fire code official, address identification shall be provided in additional approved locations to facilitate emergency response. Where access is by means of a private road and the building address cannot be viewed from the public way, a monument, pole or other approved sign or means shall be used to identify the structure. Address identification shall be maintained. 06-02-2023 8 1/2" X 11 drawings are too small to read. Please have a full set of approved readable drawings on site for all inspections. 06-05-2023 Please see 06-02-2023 Notes. 8 1/2" X 11 drawings are too small to read. Please have a full set of approved readable drawings on site for all inspections. 06-06-2023 Back left lintel is damaged. Please provide engineering concerning the back left lintel is structually sound or install new lintel. Remove soil from right side cell.
TIE BEAM / LINTEL 06/05/2023 Disapproved -FEE REQUIRED AGAETANO
Note: 6/2/2023 - PREVIOUS INSPECTION NOTES 5/30/2023 - PREVIOUS INSPECTION NOTES 05-30-2023 1. NEED APPROVED DOCUMENTS ON SITE FOR INSPECTION SITE 107.3,1 2. [F] 501.2 Address identification. New and existing buildings shall be provided with approved address identification. The address identification shall be legible and placed in a position that is visible from the street or road fronting the property. Address identification characters shall contrast with their background. Address numbers shall be Arabic numbers or alphabetical letters. Numbers shall not be spelled out. Each character shall be a minimum of 4 inches (102 mm) high with a minimum stroke width of 1/2 inch (12.7 mm). Where required by the fire code official, address identification shall be provided in additional approved locations to facilitate emergency response. Where access is by means of a private road and the building address cannot be viewed from the public way, a monument, pole or other approved sign or means shall be used to identify the structure. Address identification shall be maintained. 06-02-2023 8 1/2" X 11 drawings are too small to read. Please have a full set of approved readable drawings on site for all inspections. 06-05-2023 Please see 06-02-2023 Notes. 8 1/2" X 11 drawings are too small to read. Please have a full set of approved readable drawings on site for all inspections.
TIE BEAM / LINTEL 06/02/2023 Disapproved -FEE REQUIRED AGAETANO
Note: 5/30/2023 - PREVIOUS INSPECTION NOTES 05-30-2023 1. NEED APPROVED DOCUMENTS ON SITE FOR INSPECTION SITE 107.3,1 2. [F] 501.2 Address identification. New and existing buildings shall be provided with approved address identification. The address identification shall be legible and placed in a position that is visible from the street or road fronting the property. Address identification characters shall contrast with their background. Address numbers shall be Arabic numbers or alphabetical letters. Numbers shall not be spelled out. Each character shall be a minimum of 4 inches (102 mm) high with a minimum stroke width of 1/2 inch (12.7 mm). Where required by the fire code official, address identification shall be provided in additional approved locations to facilitate emergency response. Where access is by means of a private road and the building address cannot be viewed from the public way, a monument, pole or other approved sign or means shall be used to identify the structure. Address identification shall be maintained. 06-02-2023 8 1/2" X 11 drawings are too small to read. Please have a full set of approved readable drawings on site for all inspections.
TIE BEAM / LINTEL 05/30/2023 Disapproved - NO FEE AGAETANO
Note: 05-30-2023 1. NEED APPROVED DOCUMENTS ON SITE FOR INSPECTION SITE 107.3,1 2. [F] 501.2 Address identification. New and existing buildings shall be provided with approved address identification. The address identification shall be legible and placed in a position that is visible from the street or road fronting the property. Address identification characters shall contrast with their background. Address numbers shall be Arabic numbers or alphabetical letters. Numbers shall not be spelled out. Each character shall be a minimum of 4 inches (102 mm) high with a minimum stroke width of 1/2 inch (12.7 mm). Where required by the fire code official, address identification shall be provided in additional approved locations to facilitate emergency response. Where access is by means of a private road and the building address cannot be viewed from the public way, a monument, pole or other approved sign or means shall be used to identify the structure. Address identification shall be maintained.
MONOLITHIC SLAB 05/16/2023 APPROVED AGAETANO
Note: 5/12/2023 - PREVIOUS INSPECTION NOTES 5/11/2023 - PREVIOUS INSPECTION NOTES 05-12-2023 1. Termite bond not on site. 2. Water line through footing not protected. SLEEVES… PIPES PASSING THROUGH FOUNDATION WALLS P2603.4 SLEEVES… (SLEEVES MUST BE 2 PIPE SIZES GREATER THAN THE PIPE PASSING THROUGH THE WALL 3. Rebar minimum clearance. (minimum 3" clearance is required FBC R404.1.3.3.7.4 Check all Inspection stopped. Check head test next inspection.
MONOLITHIC SLAB 05/12/2023 Disapproved - NO FEE AGAETANO
Note: 5/11/2023 - PREVIOUS INSPECTION NOTES 05-12-2023 1. Termite bond not on site. 2. Water line through footing not protected. SLEEVES… PIPES PASSING THROUGH FOUNDATION WALLS P2603.4 SLEEVES… (SLEEVES MUST BE 2 PIPE SIZES GREATER THAN THE PIPE PASSING THROUGH THE WALL 3. Rebar minimum clearance. (minimum 3" clearance is required FBC R404.1.3.3.7.4 Check all Inspection stopped. Check head test next inspection.
MONOLITHIC SLAB 05/11/2023 CANCELLED BY APPLICANT AGAETANO
PLUMBING 1ST ROUGH UNDERGROUND 05/02/2023 APPROVED - AS NOTED MGIBSON
Note: REMOVE ALL COQUINA ROCK BEFORE BACKFILLING PLUMBING TRENCHES, AND HAVE PORTABLE RESTROOM BEFORE NEXT INSPECTION
WATER METER INSTALLATION REQUEST 04/13/2023 APPROVED CSTONE
Note: 3/20/2023 9:54:19 AM- PREVIOUS INSPECTION NOTES not cleared
WATER METER INSTALLATION REQUEST 03/16/2023 Disapproved - NO FEE CSTONE
Note: not cleared
WILDLIFE CHECK - ENVIRONMENTAL 01/09/2023 APPROVED JMYERS

Review History

Department Status Date In Date Out
BADMIN INFORMATION 07/22/2024 07/22/2024
Note: Marked INFORMATION By: MICHELLE RAMOS - (386)986-3780 - MRAMOS@PALMCOASTGOV.COM Unable to process final survey because there is a prior inspection needed. Inspection 7910 needed before final survey. Once 7910 is resulted pass then please reupload your final survey.
MECH COMPLETE 02/13/2024 02/15/2024
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
MECH COMPLETE 01/18/2024 01/22/2024
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
MECH HOLD 11/27/2023 11/28/2023
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM 1. Provide entire Energy calc with heatload and duct layout signed by the AC contractor (Second Request)
MECH HOLD 11/14/2023 11/14/2023
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM 1. Provide entire Energy calc with heatload and duct layout signed by the AC contractor 2. Energy Calcs need to be signed by the owner/ owner agent below the preparer per R103.1.1.2 FBC Energy Conservation 2020 7Th edition
BLD COMPLETE 11/09/2023 11/09/2023
Note: Released By: PATRICK BUCKLEY - (386)986-3786 - PBUCKLEY@PALMCOASTGOV.COM
BLD COMPLETE 07/06/2023 07/10/2023
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
ENGIN1 COMPLETE 06/23/2023 06/23/2023
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
ZON COMPLETE 06/23/2023 06/23/2023
Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM
BADMIN INFORMATION 06/16/2023 06/16/2023
Note: Marked INFORMATION By: SCOTT THOMAS - - STHOMAS@PALMCOASTGOV.COM NOC MISSING NOTARY AT BOTTOM
MECH COMPLETE 02/15/2023 02/15/2023
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
BADMIN INFORMATION 02/14/2023 02/14/2023
Note: Marked INFORMATION By: BARBIE BEMBRY - (386)986-3780 - BUILDINGDIVISION@PALMCOASTGOV.COM Please rename your files correctly
PLENV COMPLETE 01/09/2023 01/09/2023
Note: Released By: JORDAN MYERS, C.F.M - (386)986-2320 - JMYERS@PALMCOASTGOV.COM The Approved After Action Report has been accepted.
SW1 COMPLETE 01/09/2023 01/18/2023
Note: Released By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM
ENGIN1 COMPLETE 01/09/2023 01/11/2023
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
ZON COMPLETE 01/09/2023 01/10/2023
Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM changes made for engineering and stormwater only
ENGIN1 HOLD 10/24/2022 10/24/2022
Note: Held By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM Benchmark elevation is off from center of road elevation by .75'+/-.
MECH COMPLETE 09/06/2022 09/06/2022
Note: Released By: CHRIS PISCITELLI - (386)986-3782 - CPISCITELLI@PALMCOASTGOV.COM
ELEC COMPLETE 09/06/2022 09/06/2022
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
SW1 HOLD 09/06/2022 09/13/2022
Note: Held By: EDWARD MADISON - - EMADISON@PALMCOASTGOV.COM LEFT SIDE STILL SHOWS YOUR SDRAINAGE WILL HAVE A NEGATIVE IMPACT ON THE ADJACENT PROPERTY. NEED TO RESUBMITT A SITE PLAN SHOWING POSITIVE FLOW TO THE FRONT WITHOUT IMPACTING ADJACENT PROPERTIES
PLENV HOLD 09/06/2022 09/08/2022
Note: Held By: JORDAN MYERS, C.F.M - (386)986-2320 - JMYERS@PALMCOASTGOV.COM Comments not addressed. Staff conducted a site visit on 7/21/22 and found Potentially Occupied Gopher Tortoise Burrows. Please either provide a Gopher Tortoise survey by a QEP that shows the burrow is not within 25ft of construction activities or an approved After Action Report from FWC after relocation activities have been completed.
PLENV HOLD 07/20/2022 07/21/2022
Note: Held By: JORDAN MYERS, C.F.M - (386)986-2320 - JMYERS@PALMCOASTGOV.COM Staff conducted a site visit on 7/21/22 and found Potentially Occupied Gopher Tortoise Burrows. Please either provide a Gopher Tortoise survey by a QEP that shows the burrow is not within 25ft of construction activities or an approved After Action Report from FWC after relocation activities have been completed.
BLD COMPLETE 07/14/2022 07/18/2022
Note: Released By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM
CUSVC COMPLETE 07/14/2022 07/14/2022
Note: Released By: LISA ASBILL - - lasbill@palmcoastgov.com
ELEC HOLD 07/14/2022 07/18/2022
Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM Submit electric first floor plan
ENGIN1 COMPLETE 07/14/2022 07/14/2022
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
LOCATE COMPLETE 07/14/2022 07/14/2022
Note: Released By: CANDACE STONE - - CSTONE@PALMCOASTGOV.COM
MECH HOLD 07/14/2022 07/14/2022
Note: Held By: CHRIS PISCITELLI - (386)986-3782 - CPISCITELLI@PALMCOASTGOV.COM Orientation of Energy Calcs does not match the site plan. Revise to match per R405.4.2.1 FBC Energy Conservation 2020 7Th Edition
SW1 HOLD 07/14/2022 07/20/2022
Note: Held By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM THE DRAINAGE PATTERN IS DRAINING TO THE AJACENT LOT TO THE LEFT NEED TO KEEP ALL DRAINAGE ON YOUR LOT
ZON COMPLETE 07/14/2022 07/20/2022
Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM
SWALE COMPLETE 07/14/2022 01/24/2023
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
REINSPECTION RESIDENTIAL ¤40.00 03/25/2024
PLAN REVIEW - REVISION ¤32.50 02/22/2024
REINSPECTION RESIDENTIAL ¤40.00 02/22/2024
REINSPECTION RESIDENTIAL ¤40.00 02/22/2024
REINSPECTION RESIDENTIAL ¤40.00 12/29/2023
REINSPECTION RESIDENTIAL ¤40.00 12/29/2023
REINSPECTION RESIDENTIAL ¤40.00 12/29/2023
REINSPECTION RESIDENTIAL ¤40.00 12/29/2023
REINSPECTION RESIDENTIAL ¤40.00 12/29/2023
REINSPECTION RESIDENTIAL ¤40.00 12/29/2023
REINSPECTION RESIDENTIAL ¤40.00 12/29/2023
REINSPECTION RESIDENTIAL ¤40.00 07/17/2023
REINSPECTION RESIDENTIAL ¤40.00 07/17/2023
REINSPECTION RESIDENTIAL ¤40.00 07/17/2023
PLAN REVIEW - REVISION ¤32.50 07/17/2023
PLAN REVIEW - REVISION ¤32.50 04/13/2023
CONTRACTOR CHANGE ¤20.00 04/13/2023
3% FIRE IMPACT FEE CREDIT (¤11.66) 02/02/2023
IMPACT FEE FIRE ¤388.65 02/02/2023
IMPACT FEE PARKS ¤1,455.13 02/02/2023
IMPACT FEE SCHOOL ¤3,600.00 02/02/2023
IMPACT FEE TRANSPORTATION ¤1,764.00 02/02/2023
WATER -IRRIGATION INSPECTION ¤25.00 02/02/2023
3% PARKS IMPACT FEE CREDIT (¤43.65) 02/02/2023
SURCHARGE FS 533.721 ¤2.90 02/02/2023
SURCHARGE - FS 468.631 ¤4.35 02/02/2023
SW ENG - FOUNDATION SURVEY ¤20.00 02/02/2023
SW ENG INSPECTION 80 ¤80.00 02/02/2023
SW ENG PRE APRON ¤30.00 02/02/2023
SW ENG - REVIEW 20 ¤20.00 02/02/2023
SW ENG RES REVIEW 200 ¤200.00 02/02/2023
3% TRANS IMPACT FEE CREDIT (¤52.92) 02/02/2023
SEWER INSPECTION ¤25.00 02/02/2023
SEWER CAPITAL FACILITY ¤5,344.82 02/02/2023
WATER CAPITAL FACILITY FEE ¤3,923.88 02/02/2023
SITE PLAN 30 ¤30.00 02/02/2023
WATER- TURN ON ¤25.00 02/02/2023
ADJUSTMENT 50% (¤440.37) 02/02/2023
ADMINISTRATIVE RESIDENTIAL ¤30.00 02/02/2023
INSPECTION - RESIDENTIAL ¤662.75 02/02/2023
PLAN REVIEW - RESIDENTIAL ¤187.98 02/02/2023
CONNECTION FEES ¤1,166.26 02/02/2023
Fees Total Due: ¤0.00 Total Paid: ¤19,074.62