Permit #2022070632
Permit Details
Status: COED
| Parcel Id: 07-11-31-7007-00030-0530 |
| CONDITIONED SPACE: 1906 sqft |
| GARAGE: 400 sqft |
| OPENED PORCH (WITH ROOF) : 20 sqft |
| Total Square Footage: 2326 sqft |
| Block: 00030 |
| Subdivision: 2185 - SECTION 7-FLORIDA PARK |
| Job Phone: 470-817-1259 |
| Location Address: 64 FOXHALL LN |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 10/11/2022 |
| NOC: RECORDED |
| Applicant name: WADE GILMER JURNEY JR |
| Owner: NATIONAL HOME CORPORATION |
|
Address 4850 TAMIAMI TRAIL N NAPLES, FL 34103 |
| Lot: 0530 |
| Contracted Stated Job Value: ¤240,639.00 |
| Job Description: Single Family Residence |
| Type: CN |
Contractor
NATIONAL HOME CORPORATION
| Status | Location Address | Mailing Address | State License Number | Phone |
| INACTIVE |
1080 HOLCOMB BRIDGE ROAD , |
BLDG 100 - 330 ROSWELL , GA 30076 |
CBC1257700 (Exp: 08/31/2026) | 471-817-1259 |
Sub Contractors
DUSTIN L ESTEP
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
2041 N HIAWASSEE RD APOPKA, FL 32703 |
CCC1330971 (Exp: 08/31/2026) | 407-702-0206 | 352-988-6629 |
JASON PATRICK RIBOCK
| Status | Location Address | State License Number | Phone |
| INACTIVE |
620 E PINE ST , 0 |
ES12001313 (Exp: 08/31/2026) | 407-625-0257 |
RUSSELL J CARTER
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
PO BOX 302 DELAND, FL 32721 |
CFC1425938 (Exp: 08/31/2026) | 386-736-4220 | 386-736-4219 |
RANDALL SCOTT ROSENFELD
| Status | Location Address | State License Number | Phone |
| ACTIVE |
234 N WHITNEY ST PALM COAST, FL 32084 |
CAC1816641 (Exp: 08/31/2026) | 904-599-0082 |
Inspection History
| Type | Request Date | Result | Inspector |
| BLD - BUILDING FINAL | 12/14/2023 | FINAL APPROVED | BTAYLOR |
| Note: 12/12/2023 - PREVIOUS INSPECTION NOTES 1. No hot water. 2. No power to the outlets on the top of stairs knee wall 3. Seal the AHU closet wall and ceiling penetrations at the flex duct and the water heater conduit. 4. 2nd floor rear left side bed. Light is not working. Must be a switched controlled light or outlet. 5. The oulet at the right side of the garage to house door is not GFI protected. 6. The energy calucations are missing pages. Please have the full set onsite. Appliance types. 7. Termite cert has not been posted. | |||
| BLD - BUILDING FINAL | 12/12/2023 | Disapproved -FEE REQUIRED | JWALKER |
| Note: 1. No hot water. 2. No power to the outlets on the top of stairs knee wall 3. Seal the AHU closet wall and ceiling penetrations at the flex duct and the water heater conduit. 4. 2nd floor rear left side bed. Light is not working. Must be a switched controlled light or outlet. 5. The oulet at the right side of the garage to house door is not GFI protected. 6. The energy calucations are missing pages. Please have the full set onsite. Appliance types. 7. Termite cert has not been posted. | |||
| ELECTRIC TEMP POLE | 12/08/2023 | APPROVED | RSIMS |
| Note: 12/8/23: Temp Pole is not required as this project has already completed an approved Early Power Inspection. Inspector Notes from Inspection 2190 07/06/2023- release to FPL at 11:00AM 7/5/2023 - PREVIOUS INSPECTION NOTES painters werfe inside spraying paint, (need reschedule when inspection can be performed) | |||
| U-CROSS CONNECTION | 12/08/2023 | APPROVED | DHANEY |
| U - SEWER TIE IN | 12/08/2023 | APPROVED - AS NOTED | MGIBSON |
| Note: THIS WASA VIRTUAL INSPECTION | |||
| ROW - FINAL APRON (AFTER POUR) | 12/07/2023 | APPROVED | EMADISON |
| Note: ** 12/07/23 REPAIRS MADE TO MITERED CONCRETE ON RIGHT SIDE ___________________________________________________________________________________________________________________ 11/27/2023 - PREVIOUS INSPECTION NOTES ** 11/27/23 RIGHT5 SIDE MITERED CONCRETE END IS CRACKED 1/4 " WIDE ALL THE WAY THROUGH ** SEE ATTACHED PHOTO OF THIS INSPECTION ** 11/21/23 BEFORE STORMWATER ROW FINAL IS APPROVED ** ROAD SIDE SWALE ON LEFT SIDE NEEDS TO BE RE-ESTABLISHED CENTER OF SWALE NEEDS TO BE 8 FT FROM EDGE OF ROAD FLOW IS INCONSISTANT HIGH AND LOW ** NEED TO MATCH EXITING GRADE WITH VACANT ON LEFT IN ROW ** SEED AND STRAW REQUIRED ON ALL BARE EARTH ALONG PROPERTY LINE AND VACANT ON LEFT SIDE AND REAR ** REMOVE ALL TRASH AND CONSTRUCTION DEBRIS FROM VACANT ON LEFT AND EASEMENT IN REAR ** SEE ATTACHED PHOTOS FROM TODAYS INSPECTION _____________________________________________________________________________________________________________________ 11/15/2023 9:03:11 AM- PREVIOUS INSPECTION NOTES ** 11/14/23 ROAD SIDE SWALE ON LEFT SIDE NEEDS TO BE RE-ESTABLISHED CENTER OF SWALE NEEDS TO BE 8 FT FROM EDGE OF ROAD FLOW IS INCONSISTANT HIGH AND LOW ** ROAD SIDE SWALE ON RIGHT SIDE NEEDS TO BE RE-ESTABLISHED CENTER OF SWALE NEEDS TO BE 8 FT FROM EDGE OF ROAD FLOW IS INCONSISTANT HIGH AND LOW ** BOTH SIDES NEED TO MATCH EXISTING GRADE ** NEED TO REPAIR SWALE IN FRONT OF VACANT AND SOD ALL BARE AREAS TO MATCH EXISTING GRADE ** NEED TO SEED AND STRAW ABOVE ROW AT VACANT WHERE DISTURBED AS WELL AS ALONG THE PROPERTY LINE ON LEFT SIDE | |||
| ROW - STORMWATER FINAL | 12/07/2023 | APPROVED | EMADISON |
| Note: | |||
| U -UTILITY RESIDENTIAL FINAL | 11/27/2023 | FINAL APPROVED | JHARDING |
| ROW - STORMWATER FINAL | 11/27/2023 | Disapproved -FEE REQUIRED | EMADISON |
| Note: ** 11/27/23 BEFORE STORMWATER ROW FINAL ** ROAD SIDE SWALE ON LEFT SIDE NEEDS TO BE RE-ESTABLISHED CENTER OF SWALE NEEDS TO BE 8 FT FROM EDGE OF ROAD FLOW IS INCONSISTANT HIGH AND LOW NEEDS TO MATCH EXISTING GRADE OF VACANT ON LEFT **( NEED TO RE[PAIR SOD IN FRONT OF VACANT ** HOT PATCH ROAD REPAIR REQUIRED ** REMOVE ALL TRASH AND CONSTRUCRTION DEBRIS FROM VACANT AND EASENENT IN REAR ** SEE ATTACHED PHOTOS FROM TODAYS INSPECTION Inspector Notes from Inspection 9465 ** 11/21/23 BEFORE STORMWATER ROW FINAL ** ROAD SIDE SWALE ON LEFT SIDE NEEDS TO BE RE-ESTABLISHED CENTER OF SWALE NEEDS TO BE 8 FT FROM EDGE OF ROAD FLOW IS INCONSISTANT HIGH AND LOW ** 11/21/23 BEFORE STORMWATER ROW FINAL IS APPROVED ** ROAD SIDE SWALE ON LEFT SIDE NEEDS TO BE RE-ESTABLISHED CENTER OF SWALE NEEDS TO BE 8 FT FROM EDGE OF ROAD FLOW IS INCONSISTANT HIGH AND LOW ** NEED TO MATCH EXITING GRADE WITH VACANT ON LEFT IN ROW ** SEED AND STRAW REQUIRED ON ALL BARE EARTH ALONG PROPERTY LINE AND VACANT ON LEFT SIDE AND REAR ** REMOVE ALL TRASH AND CONSTRUCTION DEBRIS FROM VACANT ON LEFT AND EASEMENT IN REAR ** SEE ATTACHED PHOTOS FROM TODAYS INSPECTION _____________________________________________________________________________________________________________________ 11/15/2023 9:03:11 AM- PREVIOUS INSPECTION NOTES ** 11/14/23 ROAD SIDE SWALE ON LEFT SIDE NEEDS TO BE RE-ESTABLISHED CENTER OF SWALE NEEDS TO BE 8 FT FROM EDGE OF ROAD FLOW IS INCONSISTANT HIGH AND LOW ** ROAD SIDE SWALE ON RIGHT SIDE NEEDS TO BE RE-ESTABLISHED CENTER OF SWALE NEEDS TO BE 8 FT FROM EDGE OF ROAD FLOW IS INCONSISTANT HIGH AND LOW ** BOTH SIDES NEED TO MATCH EXISTING GRADE ** NEED TO REPAIR SWALE IN FRONT OF VACANT AND SOD ALL BARE AREAS TO MATCH EXISTING GRADE ** NEED TO SEED AND STRAW ABOVE ROW AT VACANT WHERE DISTURBED AS WELL AS ALONG THE PROPERTY LINE ON LEFT SIDE | |||
| ROW - FINAL APRON (AFTER POUR) | 11/27/2023 | Disapproved -FEE REQUIRED | EMADISON |
| Note: ** 11/27/23 RIGHT5 SIDE MITERED CONCRETE END IS CRACKED 1/4 " WIDE ALL THE WAY THROUGH ** SEE ATTACHED PHOTO OF THIS INSPECTION ** 11/21/23 BEFORE STORMWATER ROW FINAL IS APPROVED ** ROAD SIDE SWALE ON LEFT SIDE NEEDS TO BE RE-ESTABLISHED CENTER OF SWALE NEEDS TO BE 8 FT FROM EDGE OF ROAD FLOW IS INCONSISTANT HIGH AND LOW ** NEED TO MATCH EXITING GRADE WITH VACANT ON LEFT IN ROW ** SEED AND STRAW REQUIRED ON ALL BARE EARTH ALONG PROPERTY LINE AND VACANT ON LEFT SIDE AND REAR ** REMOVE ALL TRASH AND CONSTRUCTION DEBRIS FROM VACANT ON LEFT AND EASEMENT IN REAR ** SEE ATTACHED PHOTOS FROM TODAYS INSPECTION _____________________________________________________________________________________________________________________ 11/15/2023 9:03:11 AM- PREVIOUS INSPECTION NOTES ** 11/14/23 ROAD SIDE SWALE ON LEFT SIDE NEEDS TO BE RE-ESTABLISHED CENTER OF SWALE NEEDS TO BE 8 FT FROM EDGE OF ROAD FLOW IS INCONSISTANT HIGH AND LOW ** ROAD SIDE SWALE ON RIGHT SIDE NEEDS TO BE RE-ESTABLISHED CENTER OF SWALE NEEDS TO BE 8 FT FROM EDGE OF ROAD FLOW IS INCONSISTANT HIGH AND LOW ** BOTH SIDES NEED TO MATCH EXISTING GRADE ** NEED TO REPAIR SWALE IN FRONT OF VACANT AND SOD ALL BARE AREAS TO MATCH EXISTING GRADE ** NEED TO SEED AND STRAW ABOVE ROW AT VACANT WHERE DISTURBED AS WELL AS ALONG THE PROPERTY LINE ON LEFT SIDE | |||
| ROW FIELD SURVEY /GRADING CERTIFICATION | 11/21/2023 | APPROVED - AS NOTED | EMADISON |
| Note: ** 11/21/23 BEFORE STORMWATER ROW FINAL ** ROAD SIDE SWALE ON LEFT SIDE NEEDS TO BE RE-ESTABLISHED CENTER OF SWALE NEEDS TO BE 8 FT FROM EDGE OF ROAD FLOW IS INCONSISTANT HIGH AND LOW ** 11/21/23 BEFORE STORMWATER ROW FINAL IS APPROVED ** ROAD SIDE SWALE ON LEFT SIDE NEEDS TO BE RE-ESTABLISHED CENTER OF SWALE NEEDS TO BE 8 FT FROM EDGE OF ROAD FLOW IS INCONSISTANT HIGH AND LOW ** NEED TO MATCH EXITING GRADE WITH VACANT ON LEFT IN ROW ** SEED AND STRAW REQUIRED ON ALL BARE EARTH ALONG PROPERTY LINE AND VACANT ON LEFT SIDE AND REAR ** REMOVE ALL TRASH AND CONSTRUCTION DEBRIS FROM VACANT ON LEFT AND EASEMENT IN REAR ** SEE ATTACHED PHOTOS FROM TODAYS INSPECTION _____________________________________________________________________________________________________________________ 11/15/2023 9:03:11 AM- PREVIOUS INSPECTION NOTES ** 11/14/23 ROAD SIDE SWALE ON LEFT SIDE NEEDS TO BE RE-ESTABLISHED CENTER OF SWALE NEEDS TO BE 8 FT FROM EDGE OF ROAD FLOW IS INCONSISTANT HIGH AND LOW ** ROAD SIDE SWALE ON RIGHT SIDE NEEDS TO BE RE-ESTABLISHED CENTER OF SWALE NEEDS TO BE 8 FT FROM EDGE OF ROAD FLOW IS INCONSISTANT HIGH AND LOW ** BOTH SIDES NEED TO MATCH EXISTING GRADE ** NEED TO REPAIR SWALE IN FRONT OF VACANT AND SOD ALL BARE AREAS TO MATCH EXISTING GRADE ** NEED TO SEED AND STRAW ABOVE ROW AT VACANT WHERE DISTURBED AS WELL AS ALONG THE PROPERTY LINE ON LEFT SIDE | |||
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 11/21/2023 | APPROVED | EMADISON |
| ROW FIELD SURVEY /GRADING CERTIFICATION | 11/15/2023 | Disapproved - NO FEE | EMADISON |
| Note: ** 11/14/23 ROAD SIDE SWALE ON LEFT SIDE NEEDS TO BE RE-ESTABLISHED CENTER OF SWALE NEEDS TO BE 8 FT FROM EDGE OF ROAD FLOW IS INCONSISTANT HIGH AND LOW (NOTE WHITE PAINT) ** ROAD SIDE SWALE ON RIGHT SIDE NEEDS TO BE RE-ESTABLISHED CENTER OF SWALE NEEDS TO BE 8 FT FROM EDGE OF ROAD FLOW IS INCONSISTANT HIGH AND LOW ( NOTE WHITE PAINT) ** BOTH SIDES NEED TO MATCH EXISTING GRADE ** NEED TO REPAIR SWALE IN FRONT OF VACANT AND SOD ALL BARE AREAS TO MATCH EXISTING GRADE ** NEED TO SEED AND STRAW ABOVE ROW AT VACANT WHERE DISTURBED AS WELL AS ALONG THE PROPERTY LINE ON LEFT SIDE | |||
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 11/15/2023 | APPROVED | EMADISON |
| ROW- PRE-APRON (PRE-POUR) | 07/07/2023 | APPROVED - AS NOTED | EMADISON |
| Note: ** 07/07/23 READY TO POUR BUILDERS RESPONSIBILITY TO ENSURE CULVERT ELEVATION IS WITHIN TOLERANCE BEFORE THE POUR IN THE EVENT OF RAIN CHECK COMPACTION OF MATERIAL ** MAKE SURE THERE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL _________________________________________________________________________________________________________________________ 7/5/2023 - PREVIOUS INSPECTION NOTES ** 07/05/23 SITE NOT READFY FOR INSPECTION NO FORMS ** SEE ATTACHED PHOTOS | |||
| ELECTRIC - EARLY POWER | 07/06/2023 | APPROVED - AS NOTED | TSTAUFFACHER |
| Note: 07/06/2023- release to FPL at 11:00AM 7/5/2023 - PREVIOUS INSPECTION NOTES painters werfe inside spraying paint, (need reschedule when inspection can be performed) | |||
| ELECTRIC - EARLY POWER | 07/05/2023 | Disapproved - NO FEE | LMILLER |
| Note: painters werfe inside spraying paint, (need reschedule when inspection can be performed) | |||
| ROW- PRE-APRON (PRE-POUR) | 07/05/2023 | Disapproved -FEE REQUIRED | EMADISON |
| Note: ** 07/05/23 SITE NOT READFY FOR INSPECTION NO FORMS ** SEE ATTACHED PHOTOS | |||
| INSULATION | 06/08/2023 | APPROVED | AGAETANO |
| Note: 6/5/2023 - PREVIOUS INSPECTION NOTES | |||
| INSULATION | 06/05/2023 | CANCELLED BY APPLICANT | AGAETANO |
| ALL ROUGH | 05/23/2023 | APPROVED | TSTAUFFACHER |
| Note: 5/18/2023 - PREVIOUS INSPECTION NOTES 05/18/2023- Met with super and reigional rep along with talking to framer to find resolution. Opportunuty to look at a spray that acts as a presevative to spray between the raw non treated wood and concrete block bond beam. Suggested they discuss with an engineer for options. TS 5/16/2023 - PREVIOUS INSPECTION NOTES 5/12/2023 - PREVIOUS INSPECTION NOTES 5/4/2023 - PREVIOUS INSPECTION NOTES 5/3/2023 - PREVIOUS INSPECTION NOTES 5/1/2023 - PREVIOUS INSPECTION NOTES 4/17/2023 - PREVIOUS INSPECTION NOTES Inspector Notes from Inspection 2467 3/16/2023 - PREVIOUS INSPECTION NOTES Inspector Notes from Inspection 2460 2/13/2023 - PREVIOUS INSPECTION NOTES 2/10/2023 - PREVIOUS INSPECTION NOTES 1/23/2023 - PREVIOUS INSPECTION NOTES 01-23-2023 1. Sheet 2.1 Wall Types Legend indicates 2 x interior bearig wall. D1 FM10 interior bearing wall. First floor interior bearing walls not as per plans. Please provide details or install as per plans. 2. Interior garage wall brackets not fastened. 02-10-2023 1. Sheet 2.1 Wall Types Legend indicates 2 x interior bearig wall. D1 FM10 interior bearing wall. First floor interior bearing walls not as per plans. Please provide details or install as per plans. 2. Interior garage wall brackets not fastened. 3. WFO9 d3 not installed as per plans. 02-13-2023 1. D4 SG02 and SH01 indicates moisture barrier to be installed. All sides of floor trusses to CMU. 02-14-2023 1. D4 FB12, SG02 and SH01 indicates moisture barrier to be installed. Highlighted on drawings. All sides of floor trusses to CMU. 2. Entry header beam wall sheathing needs to be exposed for inspection. Inspector cannot verify the nailng pattern. The outside triple header nails are not completely fastened. Contractor needs to provide details where wall is not required to have hardware. Check at next inspection. Contractor can proceed at own risk. 03-16-2023 1. D4 FB12, SG02 and SH01 indicates moisture barrier to be installed. Highlighted on drawings. All sides of floor trusses to CMU. 2. Entry header beam wall sheathing needs to be exposed for inspection. Inspector cannot verify the nailng pattern. The outside triple header nails are not completely fastened. 3. Job site is a mess. Please remove trash prior to next inspection. 04-17-2023 Above issue has not been addressed. D4 FB12, SG02 and SH01 indicates moisture barrier to be installed. Highlighted on drawings. All sides of floor trusses to CMU. 05-01-2023 Above issue has not been resolved. Check all. 05-04-2023 Above issue has not been resolved. Check all. D4 FB12, SG02 and SH01 indicates moisture barrier to be installed. Highlighted on drawings. All sides of floor trusses to CMU. 05-12-2023 Above issue has not been resolved. Check all. D4 FB12, SG02 and SH01 indicates moisture barrier to be installed. Highlighted on drawings. All sides of floor trusses to CMU. 05-16-2023 Above issue has not been resolved. Check all. D4 FB12, SG02 and SH01 indicates moisture barrier to be installed. Highlighted on drawings. All sides of floor trusses to CMU. | |||
| ALL ROUGH | 05/18/2023 | Disapproved - NO FEE | TSTAUFFACHER |
| Note: 05/18/2023- Met with super and reigional rep along with talking to framer to find resolution. Opportunuty to look at a spray that acts as a presevative to spray between the raw non treated wood and concrete block bond beam. Suggested they discuss with an engineer for options. TS 5/16/2023 - PREVIOUS INSPECTION NOTES 5/12/2023 - PREVIOUS INSPECTION NOTES 5/4/2023 - PREVIOUS INSPECTION NOTES 5/3/2023 - PREVIOUS INSPECTION NOTES 5/1/2023 - PREVIOUS INSPECTION NOTES 4/17/2023 - PREVIOUS INSPECTION NOTES Inspector Notes from Inspection 2467 3/16/2023 - PREVIOUS INSPECTION NOTES Inspector Notes from Inspection 2460 2/13/2023 - PREVIOUS INSPECTION NOTES 2/10/2023 - PREVIOUS INSPECTION NOTES 1/23/2023 - PREVIOUS INSPECTION NOTES 01-23-2023 1. Sheet 2.1 Wall Types Legend indicates 2 x interior bearig wall. D1 FM10 interior bearing wall. First floor interior bearing walls not as per plans. Please provide details or install as per plans. 2. Interior garage wall brackets not fastened. 02-10-2023 1. Sheet 2.1 Wall Types Legend indicates 2 x interior bearig wall. D1 FM10 interior bearing wall. First floor interior bearing walls not as per plans. Please provide details or install as per plans. 2. Interior garage wall brackets not fastened. 3. WFO9 d3 not installed as per plans. 02-13-2023 1. D4 SG02 and SH01 indicates moisture barrier to be installed. All sides of floor trusses to CMU. 02-14-2023 1. D4 FB12, SG02 and SH01 indicates moisture barrier to be installed. Highlighted on drawings. All sides of floor trusses to CMU. 2. Entry header beam wall sheathing needs to be exposed for inspection. Inspector cannot verify the nailng pattern. The outside triple header nails are not completely fastened. Contractor needs to provide details where wall is not required to have hardware. Check at next inspection. Contractor can proceed at own risk. 03-16-2023 1. D4 FB12, SG02 and SH01 indicates moisture barrier to be installed. Highlighted on drawings. All sides of floor trusses to CMU. 2. Entry header beam wall sheathing needs to be exposed for inspection. Inspector cannot verify the nailng pattern. The outside triple header nails are not completely fastened. 3. Job site is a mess. Please remove trash prior to next inspection. 04-17-2023 Above issue has not been addressed. D4 FB12, SG02 and SH01 indicates moisture barrier to be installed. Highlighted on drawings. All sides of floor trusses to CMU. 05-01-2023 Above issue has not been resolved. Check all. 05-04-2023 Above issue has not been resolved. Check all. D4 FB12, SG02 and SH01 indicates moisture barrier to be installed. Highlighted on drawings. All sides of floor trusses to CMU. 05-12-2023 Above issue has not been resolved. Check all. D4 FB12, SG02 and SH01 indicates moisture barrier to be installed. Highlighted on drawings. All sides of floor trusses to CMU. 05-16-2023 Above issue has not been resolved. Check all. D4 FB12, SG02 and SH01 indicates moisture barrier to be installed. Highlighted on drawings. All sides of floor trusses to CMU. | |||
| LATH/BRICK/ WATER BARRIER | 05/17/2023 | APPROVED | AGAETANO |
| Note: 5/8/2023 - PREVIOUS INSPECTION NOTES 3/16/2023 - PREVIOUS INSPECTION NOTES Inspector Notes from Inspection 2460 2/13/2023 - PREVIOUS INSPECTION NOTES 2/10/2023 - PREVIOUS INSPECTION NOTES 1/23/2023 - PREVIOUS INSPECTION NOTES 01-23-2023 1. Sheet 2.1 Wall Types Legend indicates 2 x interior bearig wall. D1 FM10 interior bearing wall. First floor interior bearing walls not as per plans. Please provide details or install as per plans. 2. Interior garage wall brackets not fastened. 02-10-2023 1. Sheet 2.1 Wall Types Legend indicates 2 x interior bearig wall. D1 FM10 interior bearing wall. First floor interior bearing walls not as per plans. Please provide details or install as per plans. 2. Interior garage wall brackets not fastened. 3. WFO9 d3 not installed as per plans. 02-13-2023 1. D4 SG02 and SH01 indicates moisture barrier to be installed. All sides of floor trusses to CMU. 02-14-2023 1. D4 FB12, SG02 and SH01 indicates moisture barrier to be installed. Highlighted on drawings. All sides of floor trusses to CMU. 2. Entry header beam wall sheathing needs to be exposed for inspection. Inspector cannot verify the nailng pattern. The outside triple header nails are not completely fastened. Contractor needs to provide details where wall is not required to have hardware. Check at next inspection. Contractor can proceed at own risk. 03-16-2023 1. No window or door stops installed. 2. D4 FB12, SG02 and SH01 indicates moisture barrier to be installed. Highlighted on drawings. All sides of floor trusses to CMU. 3. Entry header beam wall sheathing needs to be exposed for inspection. Inspector cannot verify the nailng pattern. The outside triple header nails are not completely fastened. 4. Job site is a mess. Please remove trash prior to next inspection. 05-08-2023 Cancelled by applicant. | |||
| ALL ROUGH | 05/16/2023 | Disapproved -FEE REQUIRED | AGAETANO |
| Note: 5/12/2023 - PREVIOUS INSPECTION NOTES 5/4/2023 - PREVIOUS INSPECTION NOTES 5/3/2023 - PREVIOUS INSPECTION NOTES 5/1/2023 - PREVIOUS INSPECTION NOTES 4/17/2023 - PREVIOUS INSPECTION NOTES Inspector Notes from Inspection 2467 3/16/2023 - PREVIOUS INSPECTION NOTES Inspector Notes from Inspection 2460 2/13/2023 - PREVIOUS INSPECTION NOTES 2/10/2023 - PREVIOUS INSPECTION NOTES 1/23/2023 - PREVIOUS INSPECTION NOTES 01-23-2023 1. Sheet 2.1 Wall Types Legend indicates 2 x interior bearig wall. D1 FM10 interior bearing wall. First floor interior bearing walls not as per plans. Please provide details or install as per plans. 2. Interior garage wall brackets not fastened. 02-10-2023 1. Sheet 2.1 Wall Types Legend indicates 2 x interior bearig wall. D1 FM10 interior bearing wall. First floor interior bearing walls not as per plans. Please provide details or install as per plans. 2. Interior garage wall brackets not fastened. 3. WFO9 d3 not installed as per plans. 02-13-2023 1. D4 SG02 and SH01 indicates moisture barrier to be installed. All sides of floor trusses to CMU. 02-14-2023 1. D4 FB12, SG02 and SH01 indicates moisture barrier to be installed. Highlighted on drawings. All sides of floor trusses to CMU. 2. Entry header beam wall sheathing needs to be exposed for inspection. Inspector cannot verify the nailng pattern. The outside triple header nails are not completely fastened. Contractor needs to provide details where wall is not required to have hardware. Check at next inspection. Contractor can proceed at own risk. 03-16-2023 1. D4 FB12, SG02 and SH01 indicates moisture barrier to be installed. Highlighted on drawings. All sides of floor trusses to CMU. 2. Entry header beam wall sheathing needs to be exposed for inspection. Inspector cannot verify the nailng pattern. The outside triple header nails are not completely fastened. 3. Job site is a mess. Please remove trash prior to next inspection. 04-17-2023 Above issue has not been addressed. D4 FB12, SG02 and SH01 indicates moisture barrier to be installed. Highlighted on drawings. All sides of floor trusses to CMU. 05-01-2023 Above issue has not been resolved. Check all. 05-04-2023 Above issue has not been resolved. Check all. D4 FB12, SG02 and SH01 indicates moisture barrier to be installed. Highlighted on drawings. All sides of floor trusses to CMU. 05-12-2023 Above issue has not been resolved. Check all. D4 FB12, SG02 and SH01 indicates moisture barrier to be installed. Highlighted on drawings. All sides of floor trusses to CMU. 05-16-2023 Above issue has not been resolved. Check all. D4 FB12, SG02 and SH01 indicates moisture barrier to be installed. Highlighted on drawings. All sides of floor trusses to CMU. | |||
| ALL ROUGH | 05/12/2023 | Disapproved -FEE REQUIRED | AGAETANO |
| Note: 5/4/2023 - PREVIOUS INSPECTION NOTES 5/3/2023 - PREVIOUS INSPECTION NOTES 5/1/2023 - PREVIOUS INSPECTION NOTES 4/17/2023 - PREVIOUS INSPECTION NOTES Inspector Notes from Inspection 2467 3/16/2023 - PREVIOUS INSPECTION NOTES Inspector Notes from Inspection 2460 2/13/2023 - PREVIOUS INSPECTION NOTES 2/10/2023 - PREVIOUS INSPECTION NOTES 1/23/2023 - PREVIOUS INSPECTION NOTES 01-23-2023 1. Sheet 2.1 Wall Types Legend indicates 2 x interior bearig wall. D1 FM10 interior bearing wall. First floor interior bearing walls not as per plans. Please provide details or install as per plans. 2. Interior garage wall brackets not fastened. 02-10-2023 1. Sheet 2.1 Wall Types Legend indicates 2 x interior bearig wall. D1 FM10 interior bearing wall. First floor interior bearing walls not as per plans. Please provide details or install as per plans. 2. Interior garage wall brackets not fastened. 3. WFO9 d3 not installed as per plans. 02-13-2023 1. D4 SG02 and SH01 indicates moisture barrier to be installed. All sides of floor trusses to CMU. 02-14-2023 1. D4 FB12, SG02 and SH01 indicates moisture barrier to be installed. Highlighted on drawings. All sides of floor trusses to CMU. 2. Entry header beam wall sheathing needs to be exposed for inspection. Inspector cannot verify the nailng pattern. The outside triple header nails are not completely fastened. Contractor needs to provide details where wall is not required to have hardware. Check at next inspection. Contractor can proceed at own risk. 03-16-2023 1. D4 FB12, SG02 and SH01 indicates moisture barrier to be installed. Highlighted on drawings. All sides of floor trusses to CMU. 2. Entry header beam wall sheathing needs to be exposed for inspection. Inspector cannot verify the nailng pattern. The outside triple header nails are not completely fastened. 3. Job site is a mess. Please remove trash prior to next inspection. 04-17-2023 Above issue has not been addressed. D4 FB12, SG02 and SH01 indicates moisture barrier to be installed. Highlighted on drawings. All sides of floor trusses to CMU. 05-01-2023 Above issue has not been resolved. Check all. 05-04-2023 Above issue has not been resolved. Check all. D4 FB12, SG02 and SH01 indicates moisture barrier to be installed. Highlighted on drawings. All sides of floor trusses to CMU. 05-12-2023 Above issue has not been resolved. Check all. D4 FB12, SG02 and SH01 indicates moisture barrier to be installed. Highlighted on drawings. All sides of floor trusses to CMU. | |||
| LATH/BRICK/ WATER BARRIER | 05/08/2023 | CANCELLED BY APPLICANT | AGAETANO |
| Note: 3/16/2023 - PREVIOUS INSPECTION NOTES Inspector Notes from Inspection 2460 2/13/2023 - PREVIOUS INSPECTION NOTES 2/10/2023 - PREVIOUS INSPECTION NOTES 1/23/2023 - PREVIOUS INSPECTION NOTES 01-23-2023 1. Sheet 2.1 Wall Types Legend indicates 2 x interior bearig wall. D1 FM10 interior bearing wall. First floor interior bearing walls not as per plans. Please provide details or install as per plans. 2. Interior garage wall brackets not fastened. 02-10-2023 1. Sheet 2.1 Wall Types Legend indicates 2 x interior bearig wall. D1 FM10 interior bearing wall. First floor interior bearing walls not as per plans. Please provide details or install as per plans. 2. Interior garage wall brackets not fastened. 3. WFO9 d3 not installed as per plans. 02-13-2023 1. D4 SG02 and SH01 indicates moisture barrier to be installed. All sides of floor trusses to CMU. 02-14-2023 1. D4 FB12, SG02 and SH01 indicates moisture barrier to be installed. Highlighted on drawings. All sides of floor trusses to CMU. 2. Entry header beam wall sheathing needs to be exposed for inspection. Inspector cannot verify the nailng pattern. The outside triple header nails are not completely fastened. Contractor needs to provide details where wall is not required to have hardware. Check at next inspection. Contractor can proceed at own risk. 03-16-2023 1. No window or door stops installed. 2. D4 FB12, SG02 and SH01 indicates moisture barrier to be installed. Highlighted on drawings. All sides of floor trusses to CMU. 3. Entry header beam wall sheathing needs to be exposed for inspection. Inspector cannot verify the nailng pattern. The outside triple header nails are not completely fastened. 4. Job site is a mess. Please remove trash prior to next inspection. 05-08-2023 Cancelled by applicant. | |||
| ALL ROUGH | 05/04/2023 | Disapproved -FEE REQUIRED | AGAETANO |
| Note: 5/3/2023 - PREVIOUS INSPECTION NOTES 5/1/2023 - PREVIOUS INSPECTION NOTES 4/17/2023 - PREVIOUS INSPECTION NOTES Inspector Notes from Inspection 2467 3/16/2023 - PREVIOUS INSPECTION NOTES Inspector Notes from Inspection 2460 2/13/2023 - PREVIOUS INSPECTION NOTES 2/10/2023 - PREVIOUS INSPECTION NOTES 1/23/2023 - PREVIOUS INSPECTION NOTES 01-23-2023 1. Sheet 2.1 Wall Types Legend indicates 2 x interior bearig wall. D1 FM10 interior bearing wall. First floor interior bearing walls not as per plans. Please provide details or install as per plans. 2. Interior garage wall brackets not fastened. 02-10-2023 1. Sheet 2.1 Wall Types Legend indicates 2 x interior bearig wall. D1 FM10 interior bearing wall. First floor interior bearing walls not as per plans. Please provide details or install as per plans. 2. Interior garage wall brackets not fastened. 3. WFO9 d3 not installed as per plans. 02-13-2023 1. D4 SG02 and SH01 indicates moisture barrier to be installed. All sides of floor trusses to CMU. 02-14-2023 1. D4 FB12, SG02 and SH01 indicates moisture barrier to be installed. Highlighted on drawings. All sides of floor trusses to CMU. 2. Entry header beam wall sheathing needs to be exposed for inspection. Inspector cannot verify the nailng pattern. The outside triple header nails are not completely fastened. Contractor needs to provide details where wall is not required to have hardware. Check at next inspection. Contractor can proceed at own risk. 03-16-2023 1. D4 FB12, SG02 and SH01 indicates moisture barrier to be installed. Highlighted on drawings. All sides of floor trusses to CMU. 2. Entry header beam wall sheathing needs to be exposed for inspection. Inspector cannot verify the nailng pattern. The outside triple header nails are not completely fastened. 3. Job site is a mess. Please remove trash prior to next inspection. 04-17-2023 Above issue has not been addressed. D4 FB12, SG02 and SH01 indicates moisture barrier to be installed. Highlighted on drawings. All sides of floor trusses to CMU. 05-01-2023 Above issue has not been resolved. Check all. 05-04-2023 Above issue has not been resolved. Check all. D4 FB12, SG02 and SH01 indicates moisture barrier to be installed. Highlighted on drawings. All sides of floor trusses to CMU. | |||
| ALL ROUGH | 05/03/2023 | CANCELLED BY APPLICANT | AGAETANO |
| Note: 5/1/2023 - PREVIOUS INSPECTION NOTES 4/17/2023 - PREVIOUS INSPECTION NOTES Inspector Notes from Inspection 2467 3/16/2023 - PREVIOUS INSPECTION NOTES Inspector Notes from Inspection 2460 2/13/2023 - PREVIOUS INSPECTION NOTES 2/10/2023 - PREVIOUS INSPECTION NOTES 1/23/2023 - PREVIOUS INSPECTION NOTES 01-23-2023 1. Sheet 2.1 Wall Types Legend indicates 2 x interior bearig wall. D1 FM10 interior bearing wall. First floor interior bearing walls not as per plans. Please provide details or install as per plans. 2. Interior garage wall brackets not fastened. 02-10-2023 1. Sheet 2.1 Wall Types Legend indicates 2 x interior bearig wall. D1 FM10 interior bearing wall. First floor interior bearing walls not as per plans. Please provide details or install as per plans. 2. Interior garage wall brackets not fastened. 3. WFO9 d3 not installed as per plans. 02-13-2023 1. D4 SG02 and SH01 indicates moisture barrier to be installed. All sides of floor trusses to CMU. 02-14-2023 1. D4 FB12, SG02 and SH01 indicates moisture barrier to be installed. Highlighted on drawings. All sides of floor trusses to CMU. 2. Entry header beam wall sheathing needs to be exposed for inspection. Inspector cannot verify the nailng pattern. The outside triple header nails are not completely fastened. Contractor needs to provide details where wall is not required to have hardware. Check at next inspection. Contractor can proceed at own risk. 03-16-2023 1. D4 FB12, SG02 and SH01 indicates moisture barrier to be installed. Highlighted on drawings. All sides of floor trusses to CMU. 2. Entry header beam wall sheathing needs to be exposed for inspection. Inspector cannot verify the nailng pattern. The outside triple header nails are not completely fastened. 3. Job site is a mess. Please remove trash prior to next inspection. 04-17-2023 Above issue has not been addressed. D4 FB12, SG02 and SH01 indicates moisture barrier to be installed. Highlighted on drawings. All sides of floor trusses to CMU. 05-01-2023 Above issue has not been resolved. Check all. | |||
| ALL ROUGH | 05/01/2023 | Disapproved -FEE REQUIRED | AGAETANO |
| Note: 4/17/2023 - PREVIOUS INSPECTION NOTES Inspector Notes from Inspection 2467 3/16/2023 - PREVIOUS INSPECTION NOTES Inspector Notes from Inspection 2460 2/13/2023 - PREVIOUS INSPECTION NOTES 2/10/2023 - PREVIOUS INSPECTION NOTES 1/23/2023 - PREVIOUS INSPECTION NOTES 01-23-2023 1. Sheet 2.1 Wall Types Legend indicates 2 x interior bearig wall. D1 FM10 interior bearing wall. First floor interior bearing walls not as per plans. Please provide details or install as per plans. 2. Interior garage wall brackets not fastened. 02-10-2023 1. Sheet 2.1 Wall Types Legend indicates 2 x interior bearig wall. D1 FM10 interior bearing wall. First floor interior bearing walls not as per plans. Please provide details or install as per plans. 2. Interior garage wall brackets not fastened. 3. WFO9 d3 not installed as per plans. 02-13-2023 1. D4 SG02 and SH01 indicates moisture barrier to be installed. All sides of floor trusses to CMU. 02-14-2023 1. D4 FB12, SG02 and SH01 indicates moisture barrier to be installed. Highlighted on drawings. All sides of floor trusses to CMU. 2. Entry header beam wall sheathing needs to be exposed for inspection. Inspector cannot verify the nailng pattern. The outside triple header nails are not completely fastened. Contractor needs to provide details where wall is not required to have hardware. Check at next inspection. Contractor can proceed at own risk. 03-16-2023 1. D4 FB12, SG02 and SH01 indicates moisture barrier to be installed. Highlighted on drawings. All sides of floor trusses to CMU. 2. Entry header beam wall sheathing needs to be exposed for inspection. Inspector cannot verify the nailng pattern. The outside triple header nails are not completely fastened. 3. Job site is a mess. Please remove trash prior to next inspection. 04-17-2023 Above issue has not been addressed. D4 FB12, SG02 and SH01 indicates moisture barrier to be installed. Highlighted on drawings. All sides of floor trusses to CMU. 05-01-2023 Above issue has not been resolved. Check all. | |||
| ELECTRIC TEMP POLE | 04/28/2023 | CANCELLED BY APPLICANT | AGAETANO |
| ALL ROUGH | 04/17/2023 | Disapproved -FEE REQUIRED | AGAETANO |
| Note: Inspector Notes from Inspection 2467 3/16/2023 - PREVIOUS INSPECTION NOTES Inspector Notes from Inspection 2460 2/13/2023 - PREVIOUS INSPECTION NOTES 2/10/2023 - PREVIOUS INSPECTION NOTES 1/23/2023 - PREVIOUS INSPECTION NOTES 01-23-2023 1. Sheet 2.1 Wall Types Legend indicates 2 x interior bearig wall. D1 FM10 interior bearing wall. First floor interior bearing walls not as per plans. Please provide details or install as per plans. 2. Interior garage wall brackets not fastened. 02-10-2023 1. Sheet 2.1 Wall Types Legend indicates 2 x interior bearig wall. D1 FM10 interior bearing wall. First floor interior bearing walls not as per plans. Please provide details or install as per plans. 2. Interior garage wall brackets not fastened. 3. WFO9 d3 not installed as per plans. 02-13-2023 1. D4 SG02 and SH01 indicates moisture barrier to be installed. All sides of floor trusses to CMU. 02-14-2023 1. D4 FB12, SG02 and SH01 indicates moisture barrier to be installed. Highlighted on drawings. All sides of floor trusses to CMU. 2. Entry header beam wall sheathing needs to be exposed for inspection. Inspector cannot verify the nailng pattern. The outside triple header nails are not completely fastened. Contractor needs to provide details where wall is not required to have hardware. Check at next inspection. Contractor can proceed at own risk. 03-16-2023 1. D4 FB12, SG02 and SH01 indicates moisture barrier to be installed. Highlighted on drawings. All sides of floor trusses to CMU. 2. Entry header beam wall sheathing needs to be exposed for inspection. Inspector cannot verify the nailng pattern. The outside triple header nails are not completely fastened. 3. Job site is a mess. Please remove trash prior to next inspection. 04-17-2023 Above issue has not been addressed. D4 FB12, SG02 and SH01 indicates moisture barrier to be installed. Highlighted on drawings. All sides of floor trusses to CMU. | |||
| TUB SET | 04/10/2023 | CANCELLED BY INSPECTOR | MGIBSON |
| Note: NEED TO SCHEDULE ALL ROUGH INSPECTION WHEN READY | |||
| HVAC ROUGH | 04/10/2023 | CANCELLED BY INSPECTOR | RMARTIN |
| Note: NEED TO SCHEDULE THE ALL ROUGH INSPECTION, WHICH INCLUDES ELECTRICAL, PLUMBING, AND A/C | |||
| ELECTRIC 1ST ROUGH UNDERGROUND | 04/10/2023 | CANCELLED BY INSPECTOR | RMARTIN |
| Note: NEED TO SCHEDULE ALL ROUGH INSPECTION, WHICH INCLUDES ELECTRICAL, PLUMBING AND A/C | |||
| ROOF VALLEY & METAL | 04/10/2023 | APPROVED - AS NOTED | JSTEWART |
| Note: 3/16/2023 - PREVIOUS INSPECTION NOTES Inspector Notes from Inspection 2460 2/13/2023 - PREVIOUS INSPECTION NOTES 2/10/2023 - PREVIOUS INSPECTION NOTES 1/23/2023 - PREVIOUS INSPECTION NOTES 01-23-2023 1. Sheet 2.1 Wall Types Legend indicates 2 x interior bearig wall. D1 FM10 interior bearing wall. First floor interior bearing walls not as per plans. Please provide details or install as per plans. 2. Interior garage wall brackets not fastened. 02-10-2023 1. Sheet 2.1 Wall Types Legend indicates 2 x interior bearig wall. D1 FM10 interior bearing wall. First floor interior bearing walls not as per plans. Please provide details or install as per plans. 2. Interior garage wall brackets not fastened. 3. WFO9 d3 not installed as per plans. 02-13-2023 1. D4 SG02 and SH01 indicates moisture barrier to be installed. All sides of floor trusses to CMU. 02-14-2023 1. D4 FB12, SG02 and SH01 indicates moisture barrier to be installed. Highlighted on drawings. All sides of floor trusses to CMU. 2. Entry header beam wall sheathing needs to be exposed for inspection. Inspector cannot verify the nailng pattern. The outside triple header nails are not completely fastened. Contractor needs to provide details where wall is not required to have hardware. Check at next inspection. Contractor can proceed at own risk. 03-16-2023 1. D4 FB12, SG02 and SH01 indicates moisture barrier to be installed. Highlighted on drawings. All sides of floor trusses to CMU. 2. Entry header beam wall sheathing needs to be exposed for inspection. Inspector cannot verify the nailng pattern. The outside triple header nails are not completely fastened. 3. Job site is a mess. Please remove trash prior to next inspection. | |||
| ROOF VALLEY & METAL | 03/16/2023 | Disapproved -FEE REQUIRED | AGAETANO |
| Note: Inspector Notes from Inspection 2460 2/13/2023 - PREVIOUS INSPECTION NOTES 2/10/2023 - PREVIOUS INSPECTION NOTES 1/23/2023 - PREVIOUS INSPECTION NOTES 01-23-2023 1. Sheet 2.1 Wall Types Legend indicates 2 x interior bearig wall. D1 FM10 interior bearing wall. First floor interior bearing walls not as per plans. Please provide details or install as per plans. 2. Interior garage wall brackets not fastened. 02-10-2023 1. Sheet 2.1 Wall Types Legend indicates 2 x interior bearig wall. D1 FM10 interior bearing wall. First floor interior bearing walls not as per plans. Please provide details or install as per plans. 2. Interior garage wall brackets not fastened. 3. WFO9 d3 not installed as per plans. 02-13-2023 1. D4 SG02 and SH01 indicates moisture barrier to be installed. All sides of floor trusses to CMU. 02-14-2023 1. D4 FB12, SG02 and SH01 indicates moisture barrier to be installed. Highlighted on drawings. All sides of floor trusses to CMU. 2. Entry header beam wall sheathing needs to be exposed for inspection. Inspector cannot verify the nailng pattern. The outside triple header nails are not completely fastened. Contractor needs to provide details where wall is not required to have hardware. Check at next inspection. Contractor can proceed at own risk. 03-16-2023 1. D4 FB12, SG02 and SH01 indicates moisture barrier to be installed. Highlighted on drawings. All sides of floor trusses to CMU. 2. Entry header beam wall sheathing needs to be exposed for inspection. Inspector cannot verify the nailng pattern. The outside triple header nails are not completely fastened. 3. Job site is a mess. Please remove trash prior to next inspection. | |||
| LATH/BRICK/ WATER BARRIER | 03/16/2023 | Disapproved -FEE REQUIRED | AGAETANO |
| Note: Inspector Notes from Inspection 2460 2/13/2023 - PREVIOUS INSPECTION NOTES 2/10/2023 - PREVIOUS INSPECTION NOTES 1/23/2023 - PREVIOUS INSPECTION NOTES 01-23-2023 1. Sheet 2.1 Wall Types Legend indicates 2 x interior bearig wall. D1 FM10 interior bearing wall. First floor interior bearing walls not as per plans. Please provide details or install as per plans. 2. Interior garage wall brackets not fastened. 02-10-2023 1. Sheet 2.1 Wall Types Legend indicates 2 x interior bearig wall. D1 FM10 interior bearing wall. First floor interior bearing walls not as per plans. Please provide details or install as per plans. 2. Interior garage wall brackets not fastened. 3. WFO9 d3 not installed as per plans. 02-13-2023 1. D4 SG02 and SH01 indicates moisture barrier to be installed. All sides of floor trusses to CMU. 02-14-2023 1. D4 FB12, SG02 and SH01 indicates moisture barrier to be installed. Highlighted on drawings. All sides of floor trusses to CMU. 2. Entry header beam wall sheathing needs to be exposed for inspection. Inspector cannot verify the nailng pattern. The outside triple header nails are not completely fastened. Contractor needs to provide details where wall is not required to have hardware. Check at next inspection. Contractor can proceed at own risk. 03-16-2023 1. No window or door stops installed. 2. D4 FB12, SG02 and SH01 indicates moisture barrier to be installed. Highlighted on drawings. All sides of floor trusses to CMU. 3. Entry header beam wall sheathing needs to be exposed for inspection. Inspector cannot verify the nailng pattern. The outside triple header nails are not completely fastened. 4. Job site is a mess. Please remove trash prior to next inspection. | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 02/14/2023 | APPROVED - AS NOTED | AGAETANO |
| Note: 2/13/2023 - PREVIOUS INSPECTION NOTES 2/10/2023 - PREVIOUS INSPECTION NOTES 1/23/2023 - PREVIOUS INSPECTION NOTES 01-23-2023 1. Sheet 2.1 Wall Types Legend indicates 2 x interior bearig wall. D1 FM10 interior bearing wall. First floor interior bearing walls not as per plans. Please provide details or install as per plans. 2. Interior garage wall brackets not fastened. 02-10-2023 1. Sheet 2.1 Wall Types Legend indicates 2 x interior bearig wall. D1 FM10 interior bearing wall. First floor interior bearing walls not as per plans. Please provide details or install as per plans. 2. Interior garage wall brackets not fastened. 3. WFO9 d3 not installed as per plans. 02-13-2023 1. D4 SG02 and SH01 indicates moisture barrier to be installed. All sides of floor trusses to CMU. 02-14-2023 1. D4 FB12, SG02 and SH01 indicates moisture barrier to be installed. Highlighted on drawings. All sides of floor trusses to CMU. 2. Entry header beam wall sheathing needs to be exposed for inspection. Inspector cannot verify the nailng pattern. The outside triple header nails are not completely fastened. Contractor needs to provide details where wall is not required to have hardware. Check at next inspection. Contractor can proceed at own risk. | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 02/13/2023 | Disapproved -FEE REQUIRED | AGAETANO |
| Note: 2/10/2023 - PREVIOUS INSPECTION NOTES 1/23/2023 - PREVIOUS INSPECTION NOTES 01-23-2023 1. Sheet 2.1 Wall Types Legend indicates 2 x interior bearig wall. D1 FM10 interior bearing wall. First floor interior bearing walls not as per plans. Please provide details or install as per plans. 2. Interior garage wall brackets not fastened. 02-10-2023 1. Sheet 2.1 Wall Types Legend indicates 2 x interior bearig wall. D1 FM10 interior bearing wall. First floor interior bearing walls not as per plans. Please provide details or install as per plans. 2. Interior garage wall brackets not fastened. 3. WFO9 d3 not installed as per plans. 02-13-2023 1. D4 SG02 and SH01 indicates moisture barrier to be installed. All sides of floor trusses to CMU. 2. Covered entry header not exposed for inspection. Outside of triple header not nailed at the three sides. | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 02/10/2023 | Disapproved -FEE REQUIRED | AGAETANO |
| Note: 1/23/2023 - PREVIOUS INSPECTION NOTES 01-23-2023 1. Sheet 2.1 Wall Types Legend indicates 2 x interior bearig wall. D1 FM10 interior bearing wall. First floor interior bearing walls not as per plans. Please provide details or install as per plans. 2. Interior garage wall brackets not fastened. 02-10-2023 1. Sheet 2.1 Wall Types Legend indicates 2 x interior bearig wall. D1 FM10 interior bearing wall. First floor interior bearing walls not as per plans. Please provide details or install as per plans. 2. Interior garage wall brackets not fastened. 3. WFO9 d3 not installed as per plans. | |||
| WALL SHEATHING | 01/23/2023 | APPROVED - AS NOTED | AGAETANO |
| Note: 01-23-2023 Left side of garage, second floor, second sheet is missing nails. | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 01/23/2023 | Disapproved - NO FEE | AGAETANO |
| Note: 01-23-2023 1. Sheet 2.1 Wall Types Legend indicates 2 x interior bearig wall. D1 FM10 interior bearing wall. First floor interior bearing walls not as per plans. Please provide details or install as per plans. 2. Interior garage wall brackets not fastened. | |||
| FOUND SURVEY APPROVED (OFFICE) | 12/29/2022 | APPROVED | TBAKER |
| TIE BEAM / LINTEL | 12/28/2022 | APPROVED | AGAETANO |
| MONOLITHIC SLAB | 12/21/2022 | APPROVED | AGAETANO |
| PLUMBING 1ST ROUGH UNDERGROUND | 12/19/2022 | APPROVED | MGIBSON |
| GRAVITY SEWER TEST | 12/19/2022 | APPROVED | MGIBSON |
| WATER METER INSTALLATION REQUEST | 10/25/2022 | APPROVED | CSTONE |
| WILDLIFE CHECK - ENVIRONMENTAL | 07/21/2022 | APPROVED | JMYERS |
Review History
| Department | Status | Date In | Date Out |
| BADMIN | INFORMATION | 06/16/2023 | 06/16/2023 |
| Note: Marked INFORMATION By: SCOTT THOMAS - - STHOMAS@PALMCOASTGOV.COM RENAME TO NOC.PDF | |||
| BADMIN | INFORMATION | 06/16/2023 | 06/16/2023 |
| Note: Marked INFORMATION By: SCOTT THOMAS - - STHOMAS@PALMCOASTGOV.COM NOC MISSING NOTARY AT BOTTOM | |||
| MECH | COMPLETE | 02/15/2023 | 02/15/2023 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| BADMIN | INFORMATION | 02/14/2023 | 02/14/2023 |
| Note: Marked INFORMATION By: BARBIE BEMBRY - (386)986-3780 - BUILDINGDIVISION@PALMCOASTGOV.COM Please rename your files correctly | |||
| ENGIN1 | COMPLETE | 12/28/2022 | 12/29/2022 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 12/28/2022 | 12/28/2022 |
| Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 10/03/2022 | 10/03/2022 |
| Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 10/03/2022 | 10/03/2022 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| SW1 | COMPLETE | 10/03/2022 | 10/07/2022 |
| Note: Released By: ROBERT GROSS - (386)986-4769 - RGROSS@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 09/22/2022 | 09/22/2022 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| ZON | HOLD | 09/22/2022 | 09/22/2022 |
| Note: Held By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM You are submitting an approved siteplan from back in August 08, 2022. If anything has changed that you need to write that down on the revision sheet and also submit a site plan showing any changes | |||
| SW1 | COMPLETE | 09/22/2022 | 09/30/2022 |
| Note: Released By: GABRIEL BERTOLA - (386)225-3840 - GBERTOLA@PALMCOASTGOV.COM | |||
| PLENV | CANCEL | 09/07/2022 | 09/08/2022 |
| ENGIN1 | HOLD | 09/07/2022 | 09/07/2022 |
| Note: Held By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM Wrong site plan submitted with revisions | |||
| SW1 | COMPLETE | 09/07/2022 | 09/13/2022 |
| Note: Released By: EDWARD MADISON - - EMADISON@PALMCOASTGOV.COM | |||
| ZON | HOLD | 09/07/2022 | 09/08/2022 |
| Note: Held By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM You submitted a site plan for 4 Senator Court to this permit. If you need to submit a new site plan for this address, please put information on the correction/revision sheet as to what has changed since the site plan was approved in August. | |||
| MECH | COMPLETE | 08/08/2022 | 08/09/2022 |
| Note: Released By: CHRIS PISCITELLI - (386)986-3782 - CPISCITELLI@PALMCOASTGOV.COM | |||
| SW1 | COMPLETE | 08/08/2022 | 08/15/2022 |
| Note: Released By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 08/08/2022 | 08/08/2022 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 08/08/2022 | 08/08/2022 |
| Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM | |||
| PLENV | COMPLETE | 07/20/2022 | 07/21/2022 |
| Note: Released By: JORDAN MYERS, C.F.M - (386)986-2320 - JMYERS@PALMCOASTGOV.COM Staff conducted a site visit on 7/21/22 and found no Gopher Tortoise or their burrows. Staff suggests placing silt fence as soon as possible to prevent tortoise from moving into the lot. | |||
| SWALE | COMPLETE | 07/18/2022 | 10/21/2022 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| MECH | HOLD | 07/15/2022 | 07/15/2022 |
| Note: Held By: CHRIS PISCITELLI - (386)986-3782 - CPISCITELLI@PALMCOASTGOV.COM This is correct review. Previous hold comment is incorrect. Orientation of Energy Calcs does not match the site plan. Revise to match per R405.4.2.1 FBC Energy Conservation 2020 7Th Edition | |||
| BLD | COMPLETE | 07/14/2022 | 07/18/2022 |
| Note: Released By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM | |||
| CUSVC | COMPLETE | 07/14/2022 | 07/15/2022 |
| Note: Released By: LISA ASBILL - - lasbill@palmcoastgov.com | |||
| ELEC | COMPLETE | 07/14/2022 | 07/18/2022 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 07/14/2022 | 07/18/2022 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| LOCATE | COMPLETE | 07/14/2022 | 07/18/2022 |
| Note: Released By: CANDACE STONE - - CSTONE@PALMCOASTGOV.COM | |||
| MECH | HOLD | 07/14/2022 | 07/15/2022 |
| Note: Held By: CHRIS PISCITELLI - (386)986-3782 - CPISCITELLI@PALMCOASTGOV.COM R403.7.1.2.1 FBC Energy Conservation 2020 7TH Edition- Chosen equipment exceeds the maximum of 1.15 times the load calculated. | |||
| SW1 | HOLD | 07/14/2022 | 07/20/2022 |
| Note: Held By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM LOT IS DRAINING TO THE LOT TO THE RIGHT NEED TO KEEP ALL STORMWATER ON YOUR LOT | |||
| ZON | COMPLETE | 07/14/2022 | 07/20/2022 |
| Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| REINSPECTION RESIDENTIAL | ¤40.00 | 12/13/2023 |
| SW ENG REINSPECTION 20 | ¤20.00 | 12/13/2023 |
| SW ENG REINSPECTION 20 | ¤20.00 | 12/13/2023 |
| SW ENG REINSPECTION 30 | ¤30.00 | 07/17/2023 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 07/17/2023 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 07/17/2023 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 07/17/2023 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 07/17/2023 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 07/17/2023 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 04/13/2023 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 04/13/2023 |
| PLAN REVIEW - REVISION | ¤32.50 | 04/13/2023 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 04/13/2023 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 04/13/2023 |
| WATER- TURN ON | ¤25.00 | 10/11/2022 |
| ADJUSTMENT 50% | (¤440.37) | 10/11/2022 |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | 10/11/2022 |
| INSPECTION - RESIDENTIAL | ¤662.75 | 10/11/2022 |
| PLAN REVIEW - RESIDENTIAL | ¤187.98 | 10/11/2022 |
| SW ENG - REVIEW 20 | ¤20.00 | 10/11/2022 |
| SW ENG RES REVIEW 200 | ¤200.00 | 10/11/2022 |
| 3% TRANS IMPACT FEE CREDIT | (¤52.92) | 10/11/2022 |
| SEWER CREDIT | (¤1.59) | 10/11/2022 |
| SEWER INSPECTION | ¤25.00 | 10/11/2022 |
| SEWER CAPITAL FACILITY | ¤4,939.76 | 10/11/2022 |
| WATER CAPITAL FACILITY FEE | ¤3,626.50 | 10/11/2022 |
| SITE PLAN 30 | ¤30.00 | 10/11/2022 |
| CONNECTION FEES | ¤1,077.88 | 10/11/2022 |
| CONTRACTOR CHANGE | ¤20.00 | 10/11/2022 |
| CONTRACTOR CHANGE | ¤20.00 | 10/11/2022 |
| CONTRACTOR CHANGE | ¤20.00 | 10/11/2022 |
| 3% FIRE IMPACT FEE CREDIT | (¤11.66) | 10/11/2022 |
| IMPACT FEE FIRE | ¤388.65 | 10/11/2022 |
| IMPACT FEE PARKS | ¤1,455.13 | 10/11/2022 |
| IMPACT FEE SCHOOL | ¤3,600.00 | 10/11/2022 |
| IMPACT FEE TRANSPORTATION | ¤1,764.00 | 10/11/2022 |
| WATER -IRRIGATION INSPECTION | ¤25.00 | 10/11/2022 |
| 3% PARKS IMPACT FEE CREDIT | (¤43.65) | 10/11/2022 |
| SURCHARGE FS 533.721 | ¤2.90 | 10/11/2022 |
| SURCHARGE - FS 468.631 | ¤4.35 | 10/11/2022 |
| SW ENG - FOUNDATION SURVEY | ¤20.00 | 10/11/2022 |
| SW ENG INSPECTION 80 | ¤80.00 | 10/11/2022 |
| SW ENG PRE APRON | ¤30.00 | 10/11/2022 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤18,207.21 |