I want to search for...

Permit #2022070696

Permit Details

Status: COED

Parcel Id: 07-11-31-7034-01420-0100
CONDITIONED SPACE: 2430 sqft
GARAGE: 699 sqft
OPENED PORCH (WITH ROOF) : 600 sqft
Total Square Footage: 3729 sqft
Block: 01420
Subdivision: 2165 - SECTION 34-EASTHAMPTON
Job Phone: 386-627-0430
Location Address: 78 EDITH POPE DR
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 07/28/2022
NOC: RECORDED
Applicant name: ANNA WIKTORIA LISOWSKI
Owner: GORELIK GENNADIY

Address

29 VULCAN ST

STATEN ISLAND, NY 10305

Lot: 0100
Contracted Stated Job Value: ¤400,000.00
Job Description: Build single family residence
Type: CN

Contractor

GOLDEN FOX HOME REMODELING, INC
Status Location Address State License Number Phone
ACTIVE

72 HERNANDEZ AVE

PALM COAST, FL 32137

CBC1259266 (Exp: 08/31/2026) 386-627-0430

Sub Contractors

DANIEL J LUSINSKI
Status Location Address Mailing Address State License Number Phone
ACTIVE

389 PALM COAST PARKWAY SW

PALM COAST, FL 32137

#4

PALM COAST, FL 32137

CCC1330133 (Exp: 08/31/2026) 386-338-7926
JUAN CARLOS GONZALEZ
Status Location Address State License Number
ACTIVE

1328 COUNTY ROAD 308

CRESCENT CITY, FL 32112

RF11067806 (Exp: 08/31/2027)
THOMAS A REGULA
Status Location Address State License Number Phone Fax
INACTIVE

11320 PHILLIPS PKWY DRIVE E

JACKSONVILLE, FL 32256

CMC1250075 (Exp: 08/31/2026) 904-278-0339 904-278-0366
WILLIAM TODD SIKES
Status Location Address State License Number Phone
ACTIVE

83 PORT ROYAL DR

ST AUGUSTINE, FL 32084

EC0002726 (Exp: 08/31/2026) 904-762-8762

Inspection History

Type Request Date Result Inspector
BLD - BUILDING FINAL 06/13/2023 FINAL APPROVED JWALKER
Note: 6/9/2023 - PREVIOUS INSPECTION NOTES 6/9/23: 1). One of the kitchen outlets at the far right side of the counter is not GFCI protected. (1st outlet just before the laundry entrance). 2). Master bathroom right side vanity faucet has no hot water. 3). Hole in garage ceiling at seal tight for AHU needs to be sealed properly (with mastic, fire stop or joint compound) 4). Outside of hinged garage door - light fixture is not installed & there is a non weather rated cover over the box. (Install light fixture or replace cover with a weather rated one). 5). Switch is not installed for Garbage Disposal (waiting on an air switch per builder)
BLD - BUILDING FINAL 06/09/2023 Disapproved - NO FEE RSIMS
Note: 6/9/23: 1). One of the kitchen outlets at the far right side of the counter is not GFCI protected. (1st outlet just before the laundry entrance). 2). Master bathroom right side vanity faucet has no hot water. 3). Hole in garage ceiling at seal tight for AHU needs to be sealed properly (with mastic, fire stop or joint compound) 4). Outside of hinged garage door - light fixture is not installed & there is a non weather rated cover over the box. (Install light fixture or replace cover with a weather rated one). 5). Switch is not installed for Garbage Disposal (waiting on an air switch per builder)
U-CROSS CONNECTION 06/07/2023 APPROVED - AS NOTED JHARDING
Note: No cross connections.
U -UTILITY RESIDENTIAL FINAL 06/07/2023 FINAL APPROVED JHARDING
ROW - STORMWATER FINAL 06/01/2023 APPROVED GBERTOLA
Note: AT THE TIME OF THE INSPECTION EVERYTHING LOOK GOOD
ROW FIELD SURVEY /GRADING CERTIFICATION 05/30/2023 APPROVED PFLANAGAN
Note: 5/25/2023 - PREVIOUS INSPECTION NOTES CAN NOT JUST PUT DIRT ON TO THE STRUCTURE AND THEN PUT SOD DOWN. NOW YOUR FINISH SOD GRADE DON'T GIVE YOU THE MINIMUM BELOW FFE OF THE HOUSE. NEED TO FIX AREA SO WATER WILL DRAIN AWAY FROM HOUSE WITH OUT PUTTING ANY DIRT AGINST THE HOME. -------------------------------------------------------------------------------------- 5/11/2023 - PREVIOUS INSPECTION NOTES 1) THE IS A LOW AREA IN THE ROAD SIDE SWALE ALL AREAS ARE PAINTED 2) THE RIGHT SIDE OF HOUSE LOOKS LIKE YOU NEED TO HAVE MORE FALL OFF THE HOUSE
ROW - FINAL APRON (AFTER POUR) 05/30/2023 APPROVED PFLANAGAN
ROW FIELD SURVEY /GRADING CERTIFICATION 05/25/2023 Disapproved -FEE REQUIRED PFLANAGAN
Note: CAN NOT JUST PUT DIRT ON TO THE STRUCTURE AND THEN PUT SOD DOWN. NOW YOUR FINISH SOD GRADE DON'T GIVE YOU THE MINIMUM BELOW FFE OF THE HOUSE. NEED TO FIX AREA SO WATER WILL DRAIN AWAY FROM HOUSE WITH OUT PUTTING ANY DIRT AGINST THE HOME. -------------------------------------------------------------------------------------- 5/11/2023 - PREVIOUS INSPECTION NOTES 1) THE IS A LOW AREA IN THE ROAD SIDE SWALE ALL AREAS ARE PAINTED 2) THE RIGHT SIDE OF HOUSE LOOKS LIKE YOU NEED TO HAVE MORE FALL OFF THE HOUSE
ROW- FINAL SURVEY/GRADING CERTIFICATION 05/11/2023 APPROVED PFLANAGAN
ROW FIELD SURVEY /GRADING CERTIFICATION 05/11/2023 Disapproved - NO FEE PFLANAGAN
Note: 1) THE IS A LOW AREA IN THE ROAD SIDE SWALE ALL AREAS ARE PAINTED 2) THE RIGHT SIDE OF HOUSE LOOKS LIKE YOU NEED TO HAVE MORE FALL OFF THE HOUSE
ELECTRIC - EARLY POWER 04/21/2023 APPROVED RSIMS
Note: Inspector Notes from Inspection 2200 Emailed FPL @ 1424. Release Power
ROW- PRE-APRON (PRE-POUR) 04/18/2023 APPROVED GBERTOLA
Note: AT THE TIME OF THE INSPECTION CULVERT PIPE IS GOOD IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD DOUBLE CHECK CULVERT ELEVATIONS BEFORE POURING. MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL
U - SEWER TIE IN 04/06/2023 APPROVED MGIBSON
GRAVITY SEWER TEST 04/06/2023 APPROVED MGIBSON
PEP TANK INSTALLATION REQUEST 02/23/2023 APPROVED TSCHWEERS
INSULATION 02/21/2023 APPROVED LMILLER
Note: 2-21-23 notes below resolved 2/16/2023 - PREVIOUS INSPECTION NOTES 2/16/2023- 1. many romex pass thru holes need to be firestopped (double check walls with insulation) check thru out. 2. fire stop top of double wall at ac plenum in garage. 3.wires tampered with at doorway for Laundry please fasten to stud. 4. exhaust duct in bathroom tampered with 3' section cut out.
INSULATION 02/16/2023 Disapproved - NO FEE JSTEWART
Note: 2/16/2023- 1. many romex pass thru holes need to be firestopped (double check walls with insulation) check thru out. 2. fire stop top of double wall at ac plenum in garage. 3.wires tampered with at doorway for Laundry please fasten to stud. 4. exhaust duct in bathroom tampered with 3' section cut out.
ALL ROUGH 02/09/2023 APPROVED TSTAUFFACHER
Note: 2/7/2023 - PREVIOUS INSPECTION NOTES 2/7/23: Inspection stopped again! Contractors working on stucco have windows taped off. Unable to perform window installation inspection. * Also, laundry vent is pitched backwards and outside of the top plate. Will need to be boxed in for fireprotection application. 2/2/2023 - PREVIOUS INSPECTION NOTES 10/17/2022 - PREVIOUS INSPECTION NOTES 10-17-22 1. Over framing is not per detail throughout house. 10/20/22 ok to move forward to next inspection, however need an approved letter from engineer for the load bearing wall in garage where the 2x6 was installed at the floor detailing that is ok 02/02/2023-ISPECTION STOPPED_Please call back in when ready 1.Missing protection plates throughout 2.Missing staples to secure electric wires 3.Windows not installed per manufatures specifications-(gaps to jamb too large) 4.WH Pipe in bedroom outside plane of wall
ALL ROUGH 02/07/2023 Disapproved -FEE REQUIRED RSIMS
Note: 2/7/23: Inspection stopped again! Contractors working on stucco have windows taped off. Unable to perform window installation inspection. * Also, laundry vent is pitched backwards and outside of the top plate. Will need to be boxed in for fireprotection application. 2/2/2023 - PREVIOUS INSPECTION NOTES 10/17/2022 - PREVIOUS INSPECTION NOTES 10-17-22 1. Over framing is not per detail throughout house. 10/20/22 ok to move forward to next inspection, however need an approved letter from engineer for the load bearing wall in garage where the 2x6 was installed at the floor detailing that is ok 02/02/2023-ISPECTION STOPPED_Please call back in when ready 1.Missing protection plates throughout 2.Missing staples to secure electric wires 3.Windows not installed per manufatures specifications-(gaps to jamb too large) 4.WH Pipe in bedroom outside plane of wall
LATH/BRICK/ WATER BARRIER 02/06/2023 APPROVED RSIMS
ALL ROUGH 02/02/2023 Disapproved - NO FEE TSTAUFFACHER
Note: 10/17/2022 - PREVIOUS INSPECTION NOTES 10-17-22 1. Over framing is not per detail throughout house. 10/20/22 ok to move forward to next inspection, however need an approved letter from engineer for the load bearing wall in garage where the 2x6 was installed at the floor detailing that is ok 02/02/2023-ISPECTION STOPPED_Please call back in when ready 1.Missing protection plates throughout 2.Missing staples to secure electric wires 3.Windows not installed per manufatures specifications-(gaps to jamb too large) 4.WH Pipe in bedroom outside plane of wall
ELECTRIC-TUG 11/28/2022 APPROVED - AS NOTED KSANDOE
Note: Emailed FPL @ 1424. Release Power
ROOF VALLEY & METAL 10/27/2022 APPROVED JWALKER
Note: Inspector Notes from Inspection 2460 10/17/2022 - PREVIOUS INSPECTION NOTES 10-17-22 1. Over framing is not per detail throughout house. 10/20/22 ok to move forward to next inspection, however need an approved letter from engineer for the load bearing wall in garage where the 2x6 was installed at the floor detailing that is ok
ROOF SHEATHING / BRACES/TIES/DOWN CELL 10/20/2022 APPROVED - AS NOTED RMARTIN
Note: 10/17/2022 - PREVIOUS INSPECTION NOTES 10-17-22 1. Over framing is not per detail throughout house. 10/20/22 ok to move forward to next inspection, however need an approved letter from engineer for the load bearing wall in garage where the 2x6 was installed at the floor detailing that is ok
WALL SHEATHING 10/17/2022 APPROVED BTAYLOR
ROOF SHEATHING / BRACES/TIES/DOWN CELL 10/17/2022 Disapproved - NO FEE BTAYLOR
Note: 10-17-22 1. Over framing is not per detail throughout house.
FOUND SURVEY APPROVED (OFFICE) 09/15/2022 APPROVED TBAKER
TIE BEAM / LINTEL 09/12/2022 APPROVED KSANDOE
MONOLITHIC SLAB 08/23/2022 APPROVED KSANDOE
Note: THIS IS A REINSPECTION Rear footing left side of building remove the large stump from the footing. Rear of building inside footing of Lania. 2 Water distribution pipes and (1) 2" plumbing drain pipe need to be sleeved or install a relieving arch. Marked the drawings for locations.
MONOLITHIC SLAB 08/22/2022 Disapproved - NO FEE JWALKER
Note: Rear footing left side of building remove the large stump from the footing. Rear of building inside footing of Lania. 2 Water distribution pipes and (1) 2" plumbing drain pipe need to be sleeved or install a relieving arch. Marked the drawings for locations.
PLUMBING 1ST ROUGH UNDERGROUND 08/19/2022 APPROVED MGIBSON
WATER METER INSTALLATION REQUEST 08/05/2022 APPROVED CSTONE

Review History

Department Status Date In Date Out
MECH COMPLETE 05/31/2023 06/01/2023
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
ENGIN1 COMPLETE 09/15/2022 09/15/2022
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
ZON COMPLETE 09/15/2022 09/15/2022
Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM
SWALE COMPLETE 07/18/2022 10/24/2022
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
BLD COMPLETE 07/15/2022 07/18/2022
Note: Released By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM
CUSVC COMPLETE 07/15/2022 07/19/2022
Note: Released By: CYNTHIA SCHWEERS - - CSCHWEERS@PALMCOASSTGOV.COM
ELEC COMPLETE 07/15/2022 07/18/2022
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
ENGIN1 COMPLETE 07/15/2022 07/18/2022
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
LOCATE COMPLETE 07/15/2022 07/19/2022
Note: Released By: CANDACE STONE - - CSTONE@PALMCOASTGOV.COM
MECH COMPLETE 07/15/2022 07/18/2022
Note: Released By: CHRIS PISCITELLI - (386)986-3782 - CPISCITELLI@PALMCOASTGOV.COM
SW1 COMPLETE 07/15/2022 07/22/2022
Note: Released By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM
ZON COMPLETE 07/15/2022 07/20/2022
Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
PLAN REVIEW - REVISION ¤32.50 06/09/2023
REINSPECTION RESIDENTIAL ¤40.00 06/09/2023
SW ENG REINSPECTION 20 ¤20.00 06/09/2023
SW ENG - REVIEW 20 ¤20.00 07/28/2022
SW ENG RES REVIEW 200 ¤200.00 07/28/2022
3% TRANS IMPACT FEE CREDIT (¤52.92) 07/28/2022
SEWER CREDIT (¤850.00) 07/28/2022
SEWER INSPECTION ¤25.00 07/28/2022
SEWER CAPITAL FACILITY ¤4,939.76 07/28/2022
WATER CAPITAL FACILITY FEE ¤3,626.50 07/28/2022
SITE PLAN 30 ¤30.00 07/28/2022
CONNECTION FEES ¤1,077.88 07/28/2022
3% FIRE IMPACT FEE CREDIT (¤11.66) 07/28/2022
IMPACT FEE FIRE ¤388.65 07/28/2022
IMPACT FEE PARKS ¤1,455.13 07/28/2022
IMPACT FEE SCHOOL ¤3,600.00 07/28/2022
IMPACT FEE TRANSPORTATION ¤1,764.00 07/28/2022
WATER -IRRIGATION INSPECTION ¤25.00 07/28/2022
3% PARKS IMPACT FEE CREDIT (¤43.65) 07/28/2022
SURCHARGE FS 533.721 ¤11.90 07/28/2022
SURCHARGE - FS 468.631 ¤17.85 07/28/2022
SW ENG - FOUNDATION SURVEY ¤20.00 07/28/2022
SW ENG INSPECTION 80 ¤80.00 07/28/2022
SW ENG PRE APRON ¤30.00 07/28/2022
WATER- TURN ON ¤25.00 07/28/2022
ADMINISTRATIVE RESIDENTIAL ¤30.00 07/28/2022
INSPECTION - RESIDENTIAL ¤1,100.00 07/28/2022
PLAN REVIEW - RESIDENTIAL ¤312.00 07/28/2022
Fees Total Due: ¤0.00 Total Paid: ¤17,912.94