I want to search for...

Permit #2022071049

Permit Details

Status: COED

Parcel Id: 07-11-31-7012-00120-0320
CONDITIONED SPACE: 1721 sqft
GARAGE: 455 sqft
OPENED PORCH (WITH ROOF) : 173 sqft
OPENED PORCH (WITH ROOF) : 110 sqft
Total Square Footage: 2459 sqft
Block: 00120
Subdivision: 2187 - SECTION 12-BELLE TERRE
Job Phone: 631-929-5500
Location Address: 62 BALLENGER LN
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 09/26/2022
NOC: RECORDED
Applicant name: NICHOLAS JOHN ZOUMAS
Owner: WICK PALM DEVELOPMENT LLC

Address

SUITE 110

GREENWOOD VILLAGE, CO 80111

Address

5460 S QUEBEC ST

GREENWOOD VILLAGE, CO 80111

Lot: 0320
Contracted Stated Job Value: ¤160,000.00
Job Description: Single Family Home
Type: CN

Contractor

JNS CONTRACTING FLORIDA, LLC
Status Location Address State License Number Phone
ACTIVE

256 ROUTE 25A

WADING RIVER, NY 11792

CGC1527793 (Exp: 08/31/2026) 631-929-5500

Sub Contractors

NICHOLAS JOHN ZOUMAS
Status Location Address State License Number Phone
ACTIVE

256 ROUTE 25A

WADING RIVER, NY 11792

CGC1527793 (Exp: 08/31/2026) 631-929-5500
JOSEPH HORATIO STRADA JR
Status Location Address State License Number Phone
ACTIVE

3400 ST JOHNS PARKWAY

SANFORD, FL 32771

EC13003715 (Exp: 08/31/2026) 877-906-1113
JAMES MCGOVERN
Status Location Address Phone Fax
ACTIVE

PO BOX 354295

PALM COAST, FL 32137

(386)931-8940 (386)986-4835
JUAN CARLOS GONZALEZ
Status Location Address State License Number
ACTIVE

1328 COUNTY ROAD 308

CRESCENT CITY, FL 32112

RF11067806 (Exp: 08/31/2027)
MICHAEL FRANK MORELLO
Status Location Address State License Number Phone Fax
ACTIVE

2 HARGROVE GRADE

PALM COAST, FL 32164

CAC1819466 (Exp: 08/31/2026) 386-445-5023 386-446-4614

Inspection History

Type Request Date Result Inspector
BLD - BUILDING FINAL 04/21/2023 FINAL APPROVED JSTEWART
Note: 4/17/2023 - PREVIOUS INSPECTION NOTES 4/17/2023--Microwave exhaust ductwork not installed.
ROW - STORMWATER FINAL 04/21/2023 APPROVED PFLANAGAN
Note: 4/17/2023 - PREVIOUS INSPECTION NOTES ** 04/17/23 REPAIR OF ROAD SIDE SWALE ACROSS STREET IN FRONT OF VACANT STILL REQUIRED THEN SODE TO MATCH THE EXISTING GRADE ______________________________________________________________________________________________________________________ ** 04/11/23 HOT PATCH ROADREPAIR REQUIRED ** REMOVE DUMPSTER AND ALL TRASH FROM VACANT ** REPAIR AND SOD SWALE WHERE DUMPSTER WAS ON VACANT ACROSS STREET
U -UTILITY RESIDENTIAL FINAL 04/17/2023 FINAL APPROVED DHANEY
ROW - STORMWATER FINAL 04/17/2023 Disapproved -FEE REQUIRED EMADISON
Note: ** 04/17/23 REPAIR OF ROAD SIDE SWALE ACROSS STREET IN FRONT OF VACANT STILL REQUIRED THEN SODE TO MATCH THE EXISTING GRADE ______________________________________________________________________________________________________________________ ** 04/11/23 HOT PATCH ROADREPAIR REQUIRED ** REMOVE DUMPSTER AND ALL TRASH FROM VACANT ** REPAIR AND SOD SWALE WHERE DUMPSTER WAS ON VACANT ACROSS STREET
BLD - BUILDING FINAL 04/17/2023 Disapproved - NO FEE JSTEWART
Note: 4/17/2023--Microwave exhaust ductwork not installed.
FINAL SURVEY (OFFICE USE ONLY) 04/11/2023 APPROVED EMADISON
ROW - FINAL APRON (AFTER POUR) 04/11/2023 FINAL APPROVED EMADISON
ROW FIELD SURVEY /GRADING CERTIFICATION 04/11/2023 APPROVED EMADISON
Note: ** 04/11/23 HOT PATCH ROAD REPAIR REQUIRED ** REMOVE DUMPSTER AND ALL TRASH FROM VACANT ** REPAIR AND SOD SWALE WHERE DUMPSTER WAS ON VACANT ACROSS STREET
ELECTRIC - EARLY POWER 03/31/2023 APPROVED JSTEWART
Note: 3/31/2023-Email sent 1:00pm 3/29/2023 - PREVIOUS INSPECTION NOTES 3/29/2023---R319.1 Address identification. Buildings shall be provided with approved address identification. The address identification shall be legible and placed in a position that is visible from the street or road fronting the property. Address identification characters shall contrast with their background. Address numbers shall be Arabic numbers or alphabetical letters. Numbers shall not be spelled out. Each character shall be not less than 4 inches (102 mm) in height with a stroke width of not less than 0.5 inch (12.7 mm)n
ELECTRIC - EARLY POWER 03/29/2023 Disapproved -FEE REQUIRED JSTEWART
Note: 3/29/2023---R319.1 Address identification. Buildings shall be provided with approved address identification. The address identification shall be legible and placed in a position that is visible from the street or road fronting the property. Address identification characters shall contrast with their background. Address numbers shall be Arabic numbers or alphabetical letters. Numbers shall not be spelled out. Each character shall be not less than 4 inches (102 mm) in height with a stroke width of not less than 0.5 inch (12.7 mm)n
GRAVITY SEWER TEST 02/17/2023 APPROVED - AS NOTED MGIBSON
Note: THIS WAS A VIRTUAL INSPECTION
U - SEWER TIE IN 02/17/2023 APPROVED - AS NOTED MGIBSON
Note: 2/16/2023 - PREVIOUS INSPECTION NOTES THIS WAS A VIRTUAL INSPECTION
U - SEWER TIE IN 02/16/2023 CANCELLED BY APPLICANT MGIBSON
U-CROSS CONNECTION 01/19/2023 APPROVED DHANEY
ROW- PRE-APRON (PRE-POUR) 01/19/2023 APPROVED EMADISON
Note: ** 01/19/23 READY TO POUR IN THE EVENT OF RAIN RECHECK CULVERT ELEVATION AND COMPACTION ** MAKE SURE THERE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL
INSULATION 12/20/2022 APPROVED KSANDOE
Note: 12/19/2022 - PREVIOUS INSPECTION NOTES need fire blocking at range hood, 2 inch plumbing vent at top plate, and at lower ceiling locations (check all)
INSULATION 12/19/2022 Disapproved -FEE REQUIRED LMILLER
Note: need fire blocking at range hood, 2 inch plumbing vent at top plate, and at lower ceiling locations (check all) R302.11
LATH/BRICK/ WATER BARRIER 12/15/2022 APPROVED KSANDOE
ELECTRIC-TUG 12/05/2022 APPROVED JMUNSON
ALL ROUGH 12/05/2022 APPROVED DCUSHING
WALL SHEATHING 11/09/2022 APPROVED FWILLIS
ROOF SHEATHING / BRACES/TIES/DOWN CELL 11/09/2022 APPROVED FWILLIS
ROOF VALLEY & METAL 11/09/2022 APPROVED FWILLIS
FOUND SURVEY APPROVED (OFFICE) 11/07/2022 APPROVED AMOBLEY
TIE BEAM / LINTEL 10/17/2022 APPROVED FWILLIS
MONOLITHIC SLAB 10/05/2022 APPROVED FWILLIS
PLUMBING 1ST ROUGH UNDERGROUND 09/27/2022 APPROVED MGIBSON
WATER METER INSTALLATION REQUEST 09/27/2022 APPROVED CSTONE

Review History

Department Status Date In Date Out
MECH COMPLETE 03/02/2023 03/03/2023
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
ENGIN1 COMPLETE 11/07/2022 11/07/2022
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
ZON COMPLETE 11/07/2022 11/07/2022
Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM
MECH COMPLETE 10/24/2022 10/24/2022
Note: Released By: CHRIS PISCITELLI - (386)986-3782 - CPISCITELLI@PALMCOASTGOV.COM
MECH COMPLETE 07/28/2022 07/28/2022
Note: Released By: CHRIS PISCITELLI - (386)986-3782 - CPISCITELLI@PALMCOASTGOV.COM
ZON COMPLETE 07/28/2022 07/28/2022
Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM
BLD COMPLETE 07/21/2022 07/26/2022
Note: Released By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM
CUSVC COMPLETE 07/21/2022 07/22/2022
Note: Released By: CYNTHIA SCHWEERS - - CSCHWEERS@PALMCOASSTGOV.COM
ELEC COMPLETE 07/21/2022 07/22/2022
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
ENGIN1 COMPLETE 07/21/2022 07/21/2022
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
LOCATE COMPLETE 07/21/2022 07/27/2022
Note: Released By: CANDACE STONE - - CSTONE@PALMCOASTGOV.COM
MECH HOLD 07/21/2022 07/22/2022
Note: Held By: CHRIS PISCITELLI - (386)986-3782 - CPISCITELLI@PALMCOASTGOV.COM Provide Energy Calcs from correct mechanical subcontractor
SW1 COMPLETE 07/21/2022 07/27/2022
Note: Released By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM
ZON HOLD 07/21/2022 07/26/2022
Note: Held By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM Land scape does not match other plans> its for the opposite side. please correct plan
SWALE COMPLETE 07/21/2022 10/31/2022
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
PLAN REVIEW - REVISION ¤32.50 04/21/2023
PLAN REVIEW - REVISION ¤32.50 04/21/2023
REINSPECTION RESIDENTIAL ¤40.00 04/21/2023
REINSPECTION RESIDENTIAL ¤40.00 04/21/2023
SW ENG REINSPECTION 20 ¤20.00 04/21/2023
SW ENG - REVIEW 20 ¤20.00 09/26/2022
SW ENG RES REVIEW 200 ¤200.00 09/26/2022
3% TRANS IMPACT FEE CREDIT (¤52.92) 09/26/2022
SEWER INSPECTION ¤25.00 09/26/2022
SEWER CAPITAL FACILITY ¤4,939.76 09/26/2022
WATER CAPITAL FACILITY FEE ¤3,626.50 09/26/2022
SITE PLAN 30 ¤30.00 09/26/2022
WATER- TURN ON ¤25.00 09/26/2022
ADJUSTMENT 50% (¤405.07) 09/26/2022
ADMINISTRATIVE RESIDENTIAL ¤30.00 09/26/2022
INSPECTION - RESIDENTIAL ¤607.75 09/26/2022
PLAN REVIEW - RESIDENTIAL ¤172.38 09/26/2022
CONNECTION FEES ¤1,077.88 09/26/2022
CONTRACTOR CHANGE ¤40.00 09/26/2022
CONTRACTOR CHANGE ¤20.00 09/26/2022
3% FIRE IMPACT FEE CREDIT (¤11.66) 09/26/2022
IMPACT FEE FIRE ¤388.65 09/26/2022
IMPACT FEE PARKS ¤1,455.13 09/26/2022
IMPACT FEE SCHOOL ¤3,600.00 09/26/2022
IMPACT FEE TRANSPORTATION ¤1,764.00 09/26/2022
WATER -IRRIGATION INSPECTION ¤25.00 09/26/2022
3% PARKS IMPACT FEE CREDIT (¤43.65) 09/26/2022
SURCHARGE FS 533.721 ¤2.69 09/26/2022
SURCHARGE - FS 468.631 ¤4.04 09/26/2022
SW ENG - FOUNDATION SURVEY ¤20.00 09/26/2022
SW ENG INSPECTION 80 ¤80.00 09/26/2022
SW ENG PRE APRON ¤30.00 09/26/2022
Fees Total Due: ¤0.00 Total Paid: ¤17,835.48