I want to search for...

Permit #2022071283

Permit Details

Status: COED

Parcel Id: 07-11-31-7030-00070-0050
CONDITIONED SPACE: 1721 sqft
GARAGE: 455 sqft
OPENED PORCH (WITH ROOF) : 173 sqft
OPENED PORCH (WITH ROOF) : 110 sqft
Total Square Footage: 2459 sqft
Block: 00070
Subdivision: 2154 - SECTION 30-ROYAL PALMS
Job Phone: 631-929-5500
Location Address: 16 RAEMOOR DR
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 10/25/2022
NOC: RECORDED
Applicant name: NICHOLAS JOHN ZOUMAS
Owner: SEASMOKE PROPERTIES FLORIDA LLC

Address

27 WILDWOOD ROAD

SAG HARBOR, NY 11963

Lot: 0050
Contracted Stated Job Value: ¤160,000.00
Job Description: Single Family Home
Type: CN

Contractor

JNS CONTRACTING FLORIDA, LLC
Status Location Address State License Number Phone
ACTIVE

256 ROUTE 25A

WADING RIVER, NY 11792

CGC1527793 (Exp: 08/31/2026) 631-929-5500

Sub Contractors

NICHOLAS JOHN ZOUMAS
Status Location Address State License Number Phone
ACTIVE

256 ROUTE 25A

WADING RIVER, NY 11792

CGC1527793 (Exp: 08/31/2026) 631-929-5500
JAMES MCGOVERN
Status Location Address Phone Fax
ACTIVE

PO BOX 354295

PALM COAST, FL 32137

(386)931-8940 (386)986-4835
JOSEPH HORATIO STRADA JR
Status Location Address State License Number Phone
ACTIVE

3400 ST JOHNS PARKWAY

SANFORD, FL 32771

EC13003715 (Exp: 08/31/2026) 877-906-1113
JUAN CARLOS GONZALEZ
Status Location Address State License Number
ACTIVE

1328 COUNTY ROAD 308

CRESCENT CITY, FL 32112

RF11067806 (Exp: 08/31/2027)
MICHAEL FRANK MORELLO
Status Location Address State License Number Phone Fax
ACTIVE

2 HARGROVE GRADE

PALM COAST, FL 32164

CAC1819466 (Exp: 08/31/2026) 386-445-5023 386-446-4614

Inspection History

Type Request Date Result Inspector
BLD - BUILDING FINAL 06/15/2023 FINAL APPROVED JWALKER
ROW - STORMWATER FINAL 06/13/2023 FINAL APPROVED PFLANAGAN
Note: ALL CORRECTIONS MADE -------------------------------------------------------------------------------- 6/6/2023 - PREVIOUS INSPECTION NOTES 1) STILL NEED TO FIX ALL AREAS LISTED BELOW FROM THE INSPECTON DATED 6/1/23 2) NEED TO CLEAN ALL DIRT AND OVER POURED CONCRETE OUT OF CULVERT PIPE 3) NEED TO PICK UP ALL TRASH AND CONSTRUCTION DEBRIS AROUND YOUR LOT ---------------------------------------------------------------------------------------------------- 6/1/23= LEFT SIDE ACROSS FROM THE DIRECT TV ANTENNA IS A HIGH SPOT IN THE BACK YARD BY THE END OF THE PROPERTY LINE IS A LOW SPOT The subject lots drainage must not negatively impact any adjacent property. (B) B.Land Development Code Technical Manual, Section 300.01 (A)(1)(C)(6) ALL AREAS ARE (MARKED WITH PINK PAINT)
BLD - BUILDING FINAL 06/12/2023 CANCELLED BY APPLICANT WEB
ROW - STORMWATER FINAL 06/12/2023 CANCELLED BY APPLICANT WEB
Note: 6/6/2023 - PREVIOUS INSPECTION NOTES 1) STILL NEED TO FIX ALL AREAS LISTED BELOW FROM THE INSPECTON DATED 6/1/23 2) NEED TO CLEAN ALL DIRT AND OVER POURED CONCRETE OUT OF CULVERT PIPE 3) NEED TO PICK UP ALL TRASH AND CONSTRUCTION DEBRIS AROUND YOUR LOT ---------------------------------------------------------------------------------------------------- 6/1/23= LEFT SIDE ACROSS FROM THE DIRECT TV ANTENNA IS A HIGH SPOT IN THE BACK YARD BY THE END OF THE PROPERTY LINE IS A LOW SPOT The subject lots drainage must not negatively impact any adjacent property. (B) B.Land Development Code Technical Manual, Section 300.01 (A)(1)(C)(6) ALL AREAS ARE (MARKED WITH PINK PAINT)
U -UTILITY RESIDENTIAL FINAL 06/06/2023 FINAL APPROVED LFITZGERALD
ROW - STORMWATER FINAL 06/06/2023 Disapproved -FEE REQUIRED PFLANAGAN
Note: 1) STILL NEED TO FIX ALL AREAS LISTED BELOW FROM THE INSPECTON DATED 6/1/23 2) NEED TO CLEAN ALL DIRT AND OVER POURED CONCRETE OUT OF CULVERT PIPE 3) NEED TO PICK UP ALL TRASH AND CONSTRUCTION DEBRIS AROUND YOUR LOT ---------------------------------------------------------------------------------------------------- 6/1/23= LEFT SIDE ACROSS FROM THE DIRECT TV ANTENNA IS A HIGH SPOT IN THE BACK YARD BY THE END OF THE PROPERTY LINE IS A LOW SPOT The subject lots drainage must not negatively impact any adjacent property. (B) B.Land Development Code Technical Manual, Section 300.01 (A)(1)(C)(6) ALL AREAS ARE (MARKED WITH PINK PAINT)
ROW - FINAL APRON (AFTER POUR) 06/01/2023 APPROVED GBERTOLA
Note: 6/1/23=AT THE TIME OF THE INSPECTION EVERYTHING LOOK GOOD
ROW- FINAL SURVEY/GRADING CERTIFICATION 06/01/2023 APPROVED GBERTOLA
Note: 6/1/23=AT THE TIME OF THE INSPECTION EVERYTHING LOOK GOOD
ROW FIELD SURVEY /GRADING CERTIFICATION 06/01/2023 APPROVED GBERTOLA
Note: 6/1/23=AT THE TIME OF THE INSPECTION EVERYTHING LOOK GOOD
U-CROSS CONNECTION 05/26/2023 APPROVED - AS NOTED JHARDING
Note: No irrigation, no cross connections.
ELECTRIC - EARLY POWER 05/05/2023 APPROVED JWALKER
GRAVITY SEWER TEST 03/23/2023 APPROVED MGIBSON
U - SEWER TIE IN 03/23/2023 APPROVED MGIBSON
ROW- PRE-APRON (PRE-POUR) 02/01/2023 APPROVED EMADISON
Note: ** 02/01/23 READY TO POUR IN THE EVENT OF RAIN RECHECK CULVERT ELEVATION AND COMPACTIONS ** ** 02/01/23 INSPECTOR UNABLE TO ACCESS SITE DUE INSTALLATION OF PEP-TANK INSPECTOR WILL RESCHEDULE THIS PRE-POUR INSPECTION FOR 02/02/23.
INSULATION 01/30/2023 APPROVED JWALKER
PEP TANK INSTALLATION REQUEST 01/30/2023 APPROVED TSCHWEERS
ALL ROUGH 01/20/2023 APPROVED JWALKER
Note: 1/18/2023 - PREVIOUS INSPECTION NOTES Inspector Notes from Inspection 2460 1/6/2023s. 6. V trusses above garage area have not been strapped down to trusses below. 1/18/23 1. Above listed correction has not been made. 2. 2" PVC plumbing vent is to slope down to drain and be supported minimum of 4' o.c. 3. The 14" flex at the supply plenum is not connected / sealed. The duct is also kinked and compressed where in makes the two turns above garage wall area. 4. Remove the flex duct off of the microwave exhaust duct. 2" minimum clearance. 5. The 12 flex in the master bath closet needs to be lifted off the ceiling to allow for proper blowin insulation depth. 6. Install a nail plate at the microwave exhaust duct. 7. Please have a approved duct drawing onsite that matches listed subcontractor.
LATH/BRICK/ WATER BARRIER 01/18/2023 APPROVED JWALKER
Note: Inspector Notes from Inspection 2460 1/6/2023s. 2. Front entry gable install cross bracing at 48" o.c. 4. Truss A-16 missing one of tow engineering boards. I beam type install. 5. HG10A anchore at front gable end for the bottom of the cross bracing have not been installed. 6. V trusses above garage area have not been strapped down to trusses below.
ALL ROUGH 01/18/2023 Disapproved -FEE REQUIRED JWALKER
Note: Inspector Notes from Inspection 2460 1/6/2023s. 6. V trusses above garage area have not been strapped down to trusses below. 1/18/23 1. Above listed correction has not been made. 2. 2" PVC plumbing vent is to slope down to drain and be supported minimum of 4' o.c. 3. The 14" flex at the supply plenum is not connected / sealed. The duct is also kinked and compressed where in makes the two turns above garage wall area. 4. Remove the flex duct off of the microwave exhaust duct. 2" minimum clearance. 5. The 12 flex in the master bath closet needs to be lifted off the ceiling to allow for proper blowin insulation depth. 6. Install a nail plate at the microwave exhaust duct. 7. Please have a approved duct drawing onsite that matches listed subcontractor.
ROOF VALLEY & METAL 01/13/2023 APPROVED JWALKER
Note: 1/6/2023 - PREVIOUS INSPECTION NOTES Shingles have been installed.
WALL SHEATHING 01/13/2023 APPROVED JWALKER
Note: 1/6/2023 - PREVIOUS INSPECTION NOTES Metal lath has been installed.
ROOF SHEATHING / BRACES/TIES/DOWN CELL 01/13/2023 APPROVED - AS NOTED JWALKER
Note: 1/6/2023s. 2. Front entry gable install cross bracing at 48" o.c. 4. Truss A-16 missing one of tow engineering boards. I beam type install. 5. HG10A anchore at front gable end for the bottom of the cross bracing have not been installed. 6. V trusses above garage area have not been strapped down to trusses below.
ROOF VALLEY & METAL 01/06/2023 Disapproved -FEE REQUIRED JWALKER
Note: Shingles have been installed. 1/6/23 Copied note from roof brace inspection: Superintendent showed up on site during brace tie down inspection, However it was after roof valley metal was failed due to shingle install. He tore up 4 areas exposing underlayment. A fee was issued. Reinspection can be approved.
ROOF SHEATHING / BRACES/TIES/DOWN CELL 01/06/2023 Disapproved -FEE REQUIRED JWALKER
Note: 1. Cross bracing and blocking at front gables have been done with northern spruce. SYP or SPF must be uses. 2. Front entry gable install cross at 48" o.c. 3. Nail hold down strap at truss BO2A right side cmu in garage. 4. Truss A-16 missing one of tow engineering boards. I beam type install. Superintendent showed up on site during brace tie down inspection, However it was after roof valley metal was failed due to shingle install. He tore up 4 areas exposing underlayment. A fee was issued. Reinspection can be approved.
WALL SHEATHING 01/06/2023 Disapproved -FEE REQUIRED JWALKER
Note: Metal lath has been installed.
ELECTRIC-TUG 01/06/2023 APPROVED JWALKER
FOUND SURVEY APPROVED (OFFICE) 01/04/2023 APPROVED TBAKER
TIE BEAM / LINTEL 11/15/2022 APPROVED RMARTIN
MONOLITHIC SLAB 11/04/2022 APPROVED RSIMS
Note: 11/3/2022 - PREVIOUS INSPECTION NOTES 11/2/2022 - PREVIOUS INSPECTION NOTES Slab depth is to be a minimum of 3 1/2" center and right center of the slab are shallow. Dig out excess soil and tamp. Multiple areas of soil collapase into the footings under the plastic. Rebar in the left side footing not separated. 11/3/22 Above listed corrections have not been made.
MONOLITHIC SLAB 11/03/2022 Disapproved - NO FEE JWALKER
Note: 11/2/2022 - PREVIOUS INSPECTION NOTES Slab depth is to be a minimum of 3 1/2" center and right center of the slab are shallow. Dig out excess soil and tamp. Multiple areas of soil collapase into the footings under the plastic. Rebar in the left side footing not separated. 11/3/22 Above listed corrections have not been made.
MONOLITHIC SLAB 11/02/2022 Disapproved - NO FEE JWALKER
Note: Slab depth is to be a minimum of 3 1/2" center and right center of the slab are shallow. Dig out excess soil and tamp. Multiple areas of soil collapase into the footings under the plastic. Rebar in the left side footing not separated.
MONOLITHIC SLAB 11/01/2022 CANCELLED BY APPLICANT JWALKER
PLUMBING 1ST ROUGH UNDERGROUND 10/27/2022 APPROVED MGIBSON
WATER METER INSTALLATION REQUEST 10/27/2022 APPROVED CSTONE

Review History

Department Status Date In Date Out
MECH COMPLETE 03/20/2023 03/21/2023
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
ENGIN1 COMPLETE 01/04/2023 01/04/2023
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
ZON COMPLETE 01/04/2023 01/04/2023
Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM
MECH COMPLETE 12/15/2022 12/15/2022
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
ZON COMPLETE 08/04/2022 08/04/2022
Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM
BADMIN INFORMATION 08/04/2022 08/04/2022
Note: Marked INFORMATION By: SCOTT THOMAS - - STHOMAS@PALMCOASTGOV.COM PERMIT APPLICATION MISSING NOTARY AT BOTTOM
BADMIN INFORMATION 08/04/2022 08/04/2022
Note: Marked INFORMATION By: BARBIE BEMBRY - (386)986-3780 - BUILDINGDIVISION@PALMCOASTGOV.COM The address is missing from the application - job location is blank.
BLD COMPLETE 07/26/2022 07/29/2022
Note: Released By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM
CUSVC COMPLETE 07/26/2022 07/27/2022
Note: Released By: LISA ASBILL - - lasbill@palmcoastgov.com
ELEC COMPLETE 07/26/2022 07/26/2022
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
ENGIN1 COMPLETE 07/26/2022 07/26/2022
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
LOCATE COMPLETE 07/26/2022 08/01/2022
Note: Released By: CANDACE STONE - - CSTONE@PALMCOASTGOV.COM
MECH COMPLETE 07/26/2022 07/27/2022
Note: Released By: CHRIS PISCITELLI - (386)986-3782 - CPISCITELLI@PALMCOASTGOV.COM
SW1 COMPLETE 07/26/2022 08/02/2022
Note: Released By: EDWARD MADISON - - EMADISON@PALMCOASTGOV.COM
ZON HOLD 07/26/2022 07/28/2022
Note: Held By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM Wrong address chosen in the portal. All documents are for 16 Raemoor Dr
SWALE COMPLETE 07/26/2022 11/17/2022
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
PLAN REVIEW - REVISION ¤32.50 06/15/2023
PLAN REVIEW - REVISION ¤32.50 06/15/2023
REINSPECTION RESIDENTIAL ¤40.00 06/15/2023
REINSPECTION RESIDENTIAL ¤40.00 06/15/2023
REINSPECTION RESIDENTIAL ¤40.00 06/15/2023
REINSPECTION RESIDENTIAL ¤40.00 06/15/2023
SW ENG REINSPECTION 20 ¤20.00 06/15/2023
SW ENG - REVIEW 20 ¤20.00 10/25/2022
SW ENG RES REVIEW 200 ¤200.00 10/25/2022
3% TRANS IMPACT FEE CREDIT (¤52.92) 10/25/2022
SEWER CREDIT (¤1,342.00) 10/25/2022
SEWER INSPECTION ¤25.00 10/25/2022
SEWER CAPITAL FACILITY ¤4,939.76 10/25/2022
WATER CAPITAL FACILITY FEE ¤3,626.50 10/25/2022
SITE PLAN 30 ¤30.00 10/25/2022
WATER- TURN ON ¤25.00 10/25/2022
ADJUSTMENT 50% (¤405.07) 10/25/2022
ADMINISTRATIVE RESIDENTIAL ¤30.00 10/25/2022
INSPECTION - RESIDENTIAL ¤607.75 10/25/2022
PLAN REVIEW - RESIDENTIAL ¤172.38 10/25/2022
CONNECTION FEES ¤1,077.88 10/25/2022
CONTRACTOR CHANGE ¤20.00 10/25/2022
3% FIRE IMPACT FEE CREDIT (¤11.66) 10/25/2022
IMPACT FEE FIRE ¤388.65 10/25/2022
IMPACT FEE PARKS ¤1,455.13 10/25/2022
IMPACT FEE SCHOOL ¤3,600.00 10/25/2022
IMPACT FEE TRANSPORTATION ¤1,764.00 10/25/2022
WATER -IRRIGATION INSPECTION ¤25.00 10/25/2022
3% PARKS IMPACT FEE CREDIT (¤43.65) 10/25/2022
SURCHARGE FS 533.721 ¤2.69 10/25/2022
SURCHARGE - FS 468.631 ¤4.04 10/25/2022
SW ENG - FOUNDATION SURVEY ¤20.00 10/25/2022
SW ENG INSPECTION 80 ¤80.00 10/25/2022
SW ENG PRE APRON ¤30.00 10/25/2022
Fees Total Due: ¤0.00 Total Paid: ¤16,533.48