I want to search for...

Permit #2022071386

Permit Details

Status: COED

Parcel Id: 07-11-31-7065-00250-0100
CONDITIONED SPACE: 1721 sqft
OPENED PORCH (WITH ROOF) : 173 sqft
OPENED PORCH (WITH ROOF) : 110 sqft
GARAGE: 455 sqft
Total Square Footage: 2459 sqft
Block: 00250
Subdivision: 2169 - SECTION 65-KANKAKEE RUN
Job Phone: 631-929-5500
Location Address: 1 KALVERTON CT
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 11/08/2022
NOC: RECORDED
Applicant name: NICHOLAS JOHN ZOUMAS
Owner: WICK PALM DEVELOPMENT LLC

Address

SUITE 110

GREENWOOD VILLAGE, CO 80111

Address

5460 S QUEBEC ST

GREENWOOD VILLAGE, CO 80111

Lot: 0100
Contracted Stated Job Value: ¤160,000.00
Job Description: Single Family Home
Type: CN

Contractor

JNS CONTRACTING FLORIDA, LLC
Status Location Address State License Number Phone
ACTIVE

256 ROUTE 25A

WADING RIVER, NY 11792

CGC1527793 (Exp: 08/31/2026) 631-929-5500

Sub Contractors

NICHOLAS JOHN ZOUMAS
Status Location Address State License Number Phone
ACTIVE

256 ROUTE 25A

WADING RIVER, NY 11792

CGC1527793 (Exp: 08/31/2026) 631-929-5500
JUAN CARLOS GONZALEZ
Status Location Address State License Number
ACTIVE

1328 COUNTY ROAD 308

CRESCENT CITY, FL 32112

RF11067806 (Exp: 08/31/2027)
JOSEPH HORATIO STRADA JR
Status Location Address State License Number Phone
ACTIVE

3400 ST JOHNS PARKWAY

SANFORD, FL 32771

EC13003715 (Exp: 08/31/2026) 877-906-1113
JAMES MCGOVERN
Status Location Address Phone Fax
ACTIVE

PO BOX 354295

PALM COAST, FL 32137

(386)931-8940 (386)986-4835
MICHAEL FRANK MORELLO
Status Location Address State License Number Phone Fax
ACTIVE

2 HARGROVE GRADE

PALM COAST, FL 32164

CAC1819466 (Exp: 08/31/2026) 386-445-5023 386-446-4614

Inspection History

Type Request Date Result Inspector
BLD - BUILDING FINAL 12/06/2023 FINAL APPROVED BTAYLOR
Note: 12/5/2023 - PREVIOUS INSPECTION NOTES 12/5/23: 1). No hot water. (Breaker is off for Water Heater - Checked for proper orientation - OK). 2). Garage door opener safety eyes are above the 6" OC maximum height as required by UL325.6 3). Left side exterior: Hole in CMU wall at low voltage lines need to be sealed. 4). Garage: Holes in CMU wall at main plumbing feed need to be sealed properly.
BLD - BUILDING FINAL 12/05/2023 Disapproved - NO FEE RSIMS
Note: 12/5/23: 1). No hot water. (Breaker is off for Water Heater - Checked for proper orientation - OK). 2). Garage door opener safety eyes are above the 6" OC maximum height as required by UL325.6 3). Left side exterior: Hole in CMU wall at low voltage lines need to be sealed. 4). Garage: Holes in CMU wall at main plumbing feed need to be sealed properly.
U -UTILITY RESIDENTIAL FINAL 12/01/2023 FINAL APPROVED JHARDING
ROW - FINAL APRON (AFTER POUR) 06/16/2023 APPROVED GBERTOLA
Note: At the time of the inspection all minimum city requirements were met. It is the builders responsibility to ensure that nothing changes after this Inspection is approved.
ROW- FINAL SURVEY/GRADING CERTIFICATION 06/16/2023 APPROVED GBERTOLA
Note: At the time of the inspection all minimum city requirements were met. It is the builders responsibility to ensure that nothing changes after this Inspection is approved.
ROW FIELD SURVEY /GRADING CERTIFICATION 06/16/2023 APPROVED GBERTOLA
Note: At the time of the inspection all minimum city requirements were met. It is the builders responsibility to ensure that nothing changes after this Inspection is approved.
ROW - STORMWATER FINAL 06/16/2023 APPROVED GBERTOLA
Note: At the time of the inspection all minimum city requirements were met. It is the builders responsibility to ensure that nothing changes after this Inspection is approved.
ELECTRIC - EARLY POWER 03/29/2023 APPROVED RSIMS
ROW- PRE-APRON (PRE-POUR) 03/28/2023 APPROVED EMADISON
Note: ** 03/28/27 CORRECTIONS MADE READY TO POUR IN THE EVENT OF RAIN RECHECK CULVERT AND COMPACTION ** MAKE SURE THERE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL _____________________________________________________________________________________________________________________ 3/24/2023 - PREVIOUS INSPECTION NOTES ** 03/24/23 NEED TO HAVE A MINIMUM OF 6 INCHES OF CONCRETE IN APRON EDGE OF ROAD AREA IN APRON HIGH LIGHTED WITH PINK PAINT ITS TO HIGH NEED TO REMOVE MATERIAL ** AT THE TIME OF THIS INSPECTION CULVERT ELEVATION IS GOOD
ROW- PRE-APRON (PRE-POUR) 03/24/2023 Disapproved -FEE REQUIRED EMADISON
Note: ** 03/24/23 NEED TO HAVE A MINIMUM OF 6 INCHES OF CONCRETE IN APRON EDGE OF ROAD AREA IN APRON HIGH LIGHTED WITH PINK PAINT ITS TO HIGH NEED TO REMOVE MATERIAL ** AT THE TIME OF THIS INSPECTION CULVERT ELEVATION IS GOOD
U - SEWER TIE IN 03/23/2023 APPROVED MGIBSON
GRAVITY SEWER TEST 03/23/2023 APPROVED MGIBSON
PEP TANK INSTALLATION REQUEST 01/30/2023 APPROVED TSCHWEERS
Note: 1/25/2023 10:24:22 AM- PREVIOUS INSPECTION NOTES 1/20/2023 Exterior needs to be completed.
INSULATION 01/23/2023 APPROVED RSIMS
Note: New inspection due to canceled inspection New inspection due to canceled inspection 1/12/2023 - PREVIOUS INSPECTION NOTES 1/12/23: *** Baffles installed at the ceiling height change are installed on the wrong side. The baffles are intended to keep the required insulation depth at the higher ceiling height level. 1/10/2023 - PREVIOUS INSPECTION NOTES 1/10/23: 1). Missing firestop at top plate where kitchen exhaust hood duct goes through. 2). missing cardboard baffles at ceiling height changes and at back porch area.
INSULATION 01/20/2023 CANCELLED BY APPLICANT WEB
Note: New inspection due to canceled inspection 1/12/2023 - PREVIOUS INSPECTION NOTES 1/12/23: *** Baffles installed at the ceiling height change are installed on the wrong side. The baffles are intended to keep the required insulation depth at the higher ceiling height level. 1/10/2023 - PREVIOUS INSPECTION NOTES 1/10/23: 1). Missing firestop at top plate where kitchen exhaust hood duct goes through. 2). missing cardboard baffles at ceiling height changes and at back porch area.
PEP TANK INSTALLATION REQUEST 01/20/2023 Disapproved - NO FEE TSCHWEERS
Note: 1/20/2023 Exterior needs to be completed.
LATH/BRICK/ WATER BARRIER 01/20/2023 APPROVED RSIMS
Note: 1/19/2023 - PREVIOUS INSPECTION NOTES 1/19/23: Cancelled by applicant via text at @ 10:07. 1/13/2023 - PREVIOUS INSPECTION NOTES 1/13/23: Holes at wires and hose bibbs need to be sealed. Also, Persuant to the Contractor's News letter and Florida Building Codes 319.1 & 501.2 (& Emergency Services) -Address must be marked on the exterior of the home & be visible from the street with 4" tall minimum lettering. (New construction - marking the windows with flourescent or reflective paint/other is acceptable).
LATH/BRICK/ WATER BARRIER 01/19/2023 CANCELLED BY APPLICANT RSIMS
Note: 1/19/23: Cancelled by applicant via text at @ 10:07. 1/13/2023 - PREVIOUS INSPECTION NOTES 1/13/23: Holes at wires and hose bibbs need to be sealed. Also, Persuant to the Contractor's News letter and Florida Building Codes 319.1 & 501.2 (& Emergency Services) -Address must be marked on the exterior of the home & be visible from the street with 4" tall minimum lettering. (New construction - marking the windows with flourescent or reflective paint/other is acceptable).
INSULATION 01/18/2023 CANCELLED BY APPLICANT WEB
Note: 1/12/2023 - PREVIOUS INSPECTION NOTES 1/12/23: *** Baffles installed at the ceiling height change are installed on the wrong side. The baffles are intended to keep the required insulation depth at the higher ceiling height level. 1/10/2023 - PREVIOUS INSPECTION NOTES 1/10/23: 1). Missing firestop at top plate where kitchen exhaust hood duct goes through. 2). missing cardboard baffles at ceiling height changes and at back porch area.
LATH/BRICK/ WATER BARRIER 01/13/2023 Disapproved - NO FEE RSIMS
Note: 1/13/23: Holes at wires and hose bibbs need to be sealed. Also, Persuant to the Contractor's News letter and Florida Building Codes 319.1 & 501.2 (& Emergency Services) -Address must be marked on the exterior of the home & be visible from the street with 4" tall minimum lettering. (New construction - marking the windows with flourescent or reflective paint/other is acceptable).
INSULATION 01/12/2023 Disapproved -FEE REQUIRED RSIMS
Note: 1/12/23: *** Baffles installed at the ceiling height change are installed on the wrong side. The baffles are intended to keep the required insulation depth at the higher ceiling height level. 1/10/2023 - PREVIOUS INSPECTION NOTES 1/10/23: 1). Missing firestop at top plate where kitchen exhaust hood duct goes through. 2). missing cardboard baffles at ceiling height changes and at back porch area.
INSULATION 01/10/2023 Disapproved - NO FEE RSIMS
Note: 1/10/23: 1). Missing firestop at top plate where kitchen exhaust hood duct goes through. 2). missing cardboard baffles at ceiling height changes and at back porch area.
ALL ROUGH 01/06/2023 APPROVED BTAYLOR
ROOF VALLEY & METAL 12/29/2022 APPROVED RSIMS
ELECTRIC-TUG 12/28/2022 APPROVED LMILLER
U-CROSS CONNECTION 12/28/2022 APPROVED - AS NOTED JHARDING
Note: No irrigation, no cross connections.
ROOF SHEATHING / BRACES/TIES/DOWN CELL 12/27/2022 APPROVED KSANDOE
Note: 12/21/2022 - PREVIOUS INSPECTION NOTES 12/21/22: *** Roof sheathing / braces / Ties / Down Cell - Approved ----- Truss Engineering - Disapproved. 1). Tuss A17 is missing engineering. (marked on MiTech & truss layout
WALL SHEATHING 12/21/2022 APPROVED RSIMS
Note: 12/21/22: No wall sheathging on this house - 100% CMU walls. Inspection approved to move inspection process.
ROOF SHEATHING / BRACES/TIES/DOWN CELL 12/21/2022 Disapproved - NO FEE RSIMS
Note: 12/21/22: *** Roof sheathing / braces / Ties / Down Cell - Approved ----- Truss Engineering - Disapproved. 1). Tuss A17 is missing engineering. (marked on MiTech & truss layout
TIE BEAM / LINTEL 12/09/2022 APPROVED BTAYLOR
Note: 12/6/2022 - PREVIOUS INSPECTION NOTES 12/6/22: Ties checked & approved / Rebar disapproved / Window mortar beds disapproved. 1). Rebar does not not have the required clearance for down cell fill in two locations - highlighted on plans. 2). Cinderblock mortar joints are cracked and/or not complete/filled in multiple locations. Please check all. 3). All window mortar beds are in excess of the maximum thickness as required by Florida Building Code. FBC R606.3.1 Bed and head joints. Unless otherwise required or indicated on the project drawings, head and bedjoints shall be 3/8 in ch (9.5 mm) thick, except that the thickness of the bed joint of the starting course placed over foundations shall be not less than 1/4 inch (6.4 mm) and not more than 3/4 inch (19.1 mm). Mortar joint thickness for loadbearing masonry shall be within the following tolerance from the specified dimensions: 1. Bed joint: + 1/8 inch (3.2 mm). 2. Head joint: - 1/4 inch (6.4 mm), + 3/8 inch (9.5 mm). 3. Collar joints: - 1/4 inch (6.4 mm), + 3/8 inch (9.5 mm).
TIE BEAM / LINTEL 12/07/2022 Disapproved -FEE REQUIRED RSIMS
Note: 12/6/22: Ties checked & approved / Rebar disapproved / Window mortar beds disapproved. 1). Rebar does not not have the required clearance for down cell fill in two locations - highlighted on plans. 2). Cinderblock mortar joints are cracked and/or not complete/filled in multiple locations. Please check all. 3). All window mortar beds are in excess of the maximum thickness as required by Florida Building Code. FBC R606.3.1 Bed and head joints. Unless otherwise required or indicated on the project drawings, head and bedjoints shall be 3/8 in ch (9.5 mm) thick, except that the thickness of the bed joint of the starting course placed over foundations shall be not less than 1/4 inch (6.4 mm) and not more than 3/4 inch (19.1 mm). Mortar joint thickness for loadbearing masonry shall be within the following tolerance from the specified dimensions: 1. Bed joint: + 1/8 inch (3.2 mm). 2. Head joint: - 1/4 inch (6.4 mm), + 3/8 inch (9.5 mm). 3. Collar joints: - 1/4 inch (6.4 mm), + 3/8 inch (9.5 mm).
FOUND SURVEY APPROVED (OFFICE) 12/02/2022 APPROVED TBAKER
MONOLITHIC SLAB 11/17/2022 APPROVED RSIMS
PLUMBING 1ST ROUGH UNDERGROUND 11/14/2022 APPROVED MGIBSON
Note: 11/9/2022 - PREVIOUS INSPECTION NOTES NO HEAD TEST
PLUMBING 1ST ROUGH UNDERGROUND 11/09/2022 Disapproved -FEE REQUIRED MGIBSON
Note: NO HEAD TEST
WATER METER INSTALLATION REQUEST 11/09/2022 APPROVED CSTONE

Review History

Department Status Date In Date Out
MECH HOLD 01/10/2023 01/10/2023
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
MECH HOLD 01/10/2023 01/10/2023
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM update mechanical subcontractor
MECH COMPLETE 01/10/2023 01/10/2023
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
ENGIN1 COMPLETE 12/02/2022 12/02/2022
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
ZON COMPLETE 12/02/2022 12/02/2022
Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM
SW1 COMPLETE 08/16/2022 08/23/2022
Note: Released By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM
ENGIN1 COMPLETE 08/16/2022 08/16/2022
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
ZON COMPLETE 08/16/2022 08/16/2022
Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM
BLD COMPLETE 07/27/2022 08/01/2022
Note: Released By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM
CUSVC COMPLETE 07/27/2022 07/29/2022
Note: Released By: LISA ASBILL - - lasbill@palmcoastgov.com
ELEC COMPLETE 07/27/2022 07/28/2022
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
ENGIN1 COMPLETE 07/27/2022 07/27/2022
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
LOCATE COMPLETE 07/27/2022 08/03/2022
Note: Released By: CANDACE STONE - - CSTONE@PALMCOASTGOV.COM
MECH COMPLETE 07/27/2022 07/28/2022
Note: Released By: CHRIS PISCITELLI - (386)986-3782 - CPISCITELLI@PALMCOASTGOV.COM
SW1 HOLD 07/27/2022 08/03/2022
Note: Held By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM NEED TO MAKE RIGHT PROPERTY LINE A COMMON SWALE
ZON COMPLETE 07/27/2022 08/01/2022
Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM
SWALE COMPLETE 07/27/2022 11/16/2022
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
PLAN REVIEW - REVISION ¤32.50 10/20/2023
REINSPECTION RESIDENTIAL ¤40.00 10/20/2023
REINSPECTION RESIDENTIAL ¤40.00 10/20/2023
CONTRACTOR CHANGE ¤20.00 10/20/2023
SW ENG REINSPECTION 30 ¤30.00 10/20/2023
REINSPECTION RESIDENTIAL ¤40.00 11/09/2022
CONNECTION FEES ¤1,077.88 11/08/2022
11/08/2022
WATER- TURN ON ¤25.00 11/08/2022
ADJUSTMENT 50% (¤405.07) 11/08/2022
ADMINISTRATIVE RESIDENTIAL ¤30.00 11/08/2022
INSPECTION - RESIDENTIAL ¤607.75 11/08/2022
PLAN REVIEW - RESIDENTIAL ¤172.38 11/08/2022
3% FIRE IMPACT FEE CREDIT (¤11.66) 11/08/2022
IMPACT FEE FIRE ¤388.65 11/08/2022
IMPACT FEE PARKS ¤1,455.13 11/08/2022
IMPACT FEE SCHOOL ¤3,600.00 11/08/2022
IMPACT FEE TRANSPORTATION ¤1,764.00 11/08/2022
WATER -IRRIGATION INSPECTION ¤25.00 11/08/2022
3% PARKS IMPACT FEE CREDIT (¤43.65) 11/08/2022
SURCHARGE FS 533.721 ¤2.69 11/08/2022
SURCHARGE - FS 468.631 ¤4.04 11/08/2022
SW ENG - FOUNDATION SURVEY ¤20.00 11/08/2022
SW ENG INSPECTION 80 ¤80.00 11/08/2022
SW ENG PRE APRON ¤30.00 11/08/2022
SW ENG - REVIEW 20 ¤20.00 11/08/2022
SW ENG RES REVIEW 200 ¤200.00 11/08/2022
3% TRANS IMPACT FEE CREDIT (¤52.92) 11/08/2022
SEWER INSPECTION ¤25.00 11/08/2022
SEWER CAPITAL FACILITY ¤4,939.76 11/08/2022
WATER CAPITAL FACILITY FEE ¤3,626.50 11/08/2022
SITE PLAN 30 ¤30.00 11/08/2022
Fees Total Due: ¤0.00 Total Paid: ¤17,812.98