I want to search for...

Permit #2022080396

Permit Details

Status: COED

Parcel Id: 07-11-31-7065-00490-0150
CONDITIONED SPACE: 1721 sqft
OPENED PORCH (WITH ROOF) : 173 sqft
OPENED PORCH (WITH ROOF) : 110 sqft
GARAGE: 455 sqft
Total Square Footage: 2459 sqft
Block: 00490
Subdivision: -
Job Phone: 631-929-5500
Location Address: 117 KARAS TR
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 03/03/2023
NOC: RECORDED
Applicant name: NICHOLAS JOHN ZOUMAS
Owner: WICK PALM DEVELOPMENT LLC

Address

SUITE 110

GREENWOOD VILLAGE, CO 80111

Address

5460 S QUEBEC ST

GREENWOOD VILLAGE, CO 80111

Lot: 0150
Contracted Stated Job Value: ¤160,000.00
Job Description: Single Family Home
Type: CN

Contractor

JNS CONTRACTING FLORIDA, LLC
Status Location Address State License Number Phone
ACTIVE

256 ROUTE 25A

WADING RIVER, NY 11792

CGC1527793 (Exp: 08/31/2026) 631-929-5500

Sub Contractors

NICHOLAS JOHN ZOUMAS
Status Location Address State License Number Phone
ACTIVE

256 ROUTE 25A

WADING RIVER, NY 11792

CGC1527793 (Exp: 08/31/2026) 631-929-5500
JOSEPH HORATIO STRADA JR
Status Location Address State License Number Phone
ACTIVE

3400 ST JOHNS PARKWAY

SANFORD, FL 32771

EC13003715 (Exp: 08/31/2026) 877-906-1113
JAMES MCGOVERN
Status Location Address Phone Fax
ACTIVE

PO BOX 354295

PALM COAST, FL 32137

(386)931-8940 (386)986-4835
JUAN CARLOS GONZALEZ
Status Location Address State License Number
ACTIVE

1328 COUNTY ROAD 308

CRESCENT CITY, FL 32112

RF11067806 (Exp: 08/31/2027)
MICHAEL FRANK MORELLO
Status Location Address State License Number Phone Fax
ACTIVE

2 HARGROVE GRADE

PALM COAST, FL 32164

CAC1819466 (Exp: 08/31/2026) 386-445-5023 386-446-4614

Inspection History

Type Request Date Result Inspector
BLD - BUILDING FINAL 12/12/2023 FINAL APPROVED KSANDOE
ROW - STORMWATER FINAL 12/12/2023 APPROVED TPOLACEK
Note: AT THE TIME FROM THE TIME OF THE INSPECTION OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED. THIS INCLUDES BUT IS NOT LIMITED TO THE CULVERT PIPE ELEVATION APPROVAL FOR THE CONCRETE POUR.
U -UTILITY RESIDENTIAL FINAL 12/12/2023 FINAL APPROVED JHARDING
ROW FIELD SURVEY /GRADING CERTIFICATION 12/08/2023 APPROVED GBERTOLA
Note: 12/08/23=CORRECTION WERE MADE AT THE TIME FROM THE TIME OF THE INSPECTION OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED. THIS INCLUDES BUT IS NOT LIMITED TO THE CULVERT PIPE ELEVATION APPROVAL FOR THE CONCRETE POUR. +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 0/2/23= THE ROAD SIDE SWALE ON THE RIGHT SIDE OF DRIVEWAY NEED TO BE 8' OFF THE EDGE OF PAVEMENT NEEDS TO RAISE THE FRONT PROPERTY LINE ON THE LEFT SIDE . +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 8/25/2023 - PREVIOUS INSPECTION NOTES 1) NEED ALL BARE AREAS IN THE LOT SODED 2) THE ROAD SIDE SWALE ON THE RIGHT SIDE OF DRIVEWAY NEED TO BE 8' OFF THE EDGE OF PAVEMENT 3) SOD AGAINST THE HOUSE IS WASHING OUT
ROW - FINAL APRON (AFTER POUR) 12/08/2023 APPROVED GBERTOLA
Note: AT THE TIME FROM THE TIME OF THE INSPECTION OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED. THIS INCLUDES BUT IS NOT LIMITED TO THE CULVERT PIPE ELEVATION APPROVAL FOR THE CONCRETE POUR.
ROW- PROJECT STATUS 12/08/2023 APPROVED GBERTOLA
Note: MEETING WITH THE BUILDER
ROW- PROJECT STATUS 11/15/2023 APPROVED GBERTOLA
Note: builder ask me to stop by
ROW- PROJECT STATUS 10/02/2023 APPROVED GBERTOLA
Note: 10/2/23= THE ROAD SIDE SWALE ON THE RIGHT SIDE OF DRIVEWAY NEED TO BE 8' OFF THE EDGE OF PAVEMENT NEEDS TO RAISE THE FRONT PROPERTY LINE ON THE LEFT SIDE .
ROW- FINAL SURVEY/GRADING CERTIFICATION 08/25/2023 APPROVED PFLANAGAN
Note: At the time of the inspection all minimum city requirements were met. It is the builders responsibiliy to ensure that nothing changes after this Inspection is approved.
ROW FIELD SURVEY /GRADING CERTIFICATION 08/25/2023 Disapproved - NO FEE PFLANAGAN
Note: 1) NEED ALL BARE AREAS IN THE LOT SODED 2) THE ROAD SIDE SWALE ON THE RIGHT SIDE OF DRIVEWAY NEED TO BE 8' OFF THE EDGE OF PAVEMENT 3) SOD AGAINST THE HOUSE IS WASHING OUT
ELECTRIC - EARLY POWER 07/20/2023 APPROVED - AS NOTED BTAYLOR
Note: Inspector Notes from Inspection 2200 4-21-23 1. Emailed FPL at 9:24. 7-20-23 1. Emailed FPL at 9:35.
GRAVITY SEWER TEST 06/15/2023 APPROVED MGIBSON
U - SEWER TIE IN 06/15/2023 APPROVED MGIBSON
ROW- PRE-APRON (PRE-POUR) 06/09/2023 APPROVED PFLANAGAN
Note: ALL CORRECTIONS MADE IT'S YOUR RESPONSIBILITY TO CHECK THE CULVERT PIPE EKEVATIONS BEFORE POURING THE CONCRETE ALL CONCRETE NEEDS TO BE A MINIMUM OF 3000PSI WITH FIBER OR WITH METAL MESH IN CONCRETE TO MEET ALL CITY'S STANDARTS ----------------------------------------------------------------------------------------------- 6/8/2023 - PREVIOUS INSPECTION NOTES STILL NEED TO MOVE FORM BOARD AT EDGE OF PAVEMENT OUT OF ROAD WAY. ---------------------------------------------------------------------------------------- 6/5/2023 - PREVIOUS INSPECTION NOTES 1) NEED TO MOVE FORM BOARD AT EDGE OF PAVEMENT OUT OF ROAD WAY. 2) NEED TO HAVE DIRT ON THE OUTSIDE OF FORMS SO CONCRETE WILL STAY IN POURING AREA. CULVERT IS GOOD AT THIS TIME
ROW- PRE-APRON (PRE-POUR) 06/08/2023 Disapproved -FEE REQUIRED PFLANAGAN
Note: STILL NEED TO MOVE FORM BOARD AT EDGE OF PAVEMENT OUT OF ROAD WAY. PLEASE SEE PHOTOS ---------------------------------------------------------------------------------------- 6/5/2023 - PREVIOUS INSPECTION NOTES 1) NEED TO MOVE FORM BOARD AT EDGE OF PAVEMENT OUT OF ROAD WAY. 2) NEED TO HAVE DIRT ON THE OUTSIDE OF FORMS SO CONCRETE WILL STAY IN POURING AREA. CULVERT IS GOOD AT THIS TIME
ROW- PRE-APRON (PRE-POUR) 06/05/2023 Disapproved -FEE REQUIRED PFLANAGAN
Note: 1) NEED TO MOVE FORM BOARD AT EDGE OF PAVEMENT OUT OF ROAD WAY. 2) NEED TO HAVE DIRT ON THE OUTSIDE OF FORMS SO CONCRETE WILL STAY IN POURING AREA. CULVERT IS GOOD AT THIS TIME
INSULATION 05/24/2023 APPROVED RSIMS
Note: 5/23/2023 - PREVIOUS INSPECTION NOTES 5/23/23: Missing firestop at Top Plate penetrations in the following locations: (marked on stud with FS below). 1).thermostat wire in garage & house 2). Kitchen range exhaust. 3). Partial penetration outside of laundry room. 4). At PVC plumbing vent stacks in both Laundry room & Hall bathroom. --- 5). Missing Firestop at Horizontal wire runs over 10ft. Per FBC 302.11: Required Locations (1.2. Horizontally at intervals not exceeding 10 feet (3048 mm)). Both left & right sides of house. 6). Laundry room - Missing firestop at PT lathe & 2" x 6" pack out wall intersection. Inspector Notes from Inspection 2420 5/16/23: Must be complete prior to Insulation Inspection. Check at Insulation! *** Need to move wall mounted combo detector outside of Master Bedroom to better match location on plan detail. (To cover common area as intended). Inspector Notes from Inspection 2320 4/25/23: Please have the permit box mounted in the front of the property as required (not laying in the garage).
INSULATION 05/23/2023 Disapproved -FEE REQUIRED RSIMS
Note: 5/23/23: Missing firestop at Top Plate penetrations in the following locations: (marked on stud with FS below). 1).thermostat wire in garage & house 2). Kitchen range exhaust. 3). Partial penetration outside of laundry room. 4). At PVC plumbing vent stacks in both Laundry room & Hall bathroom. --- 5). Missing Firestop at Horizontal wire runs over 10ft. Per FBC 302.11: Required Locations (1.2. Horizontally at intervals not exceeding 10 feet (3048 mm)). Both left & right sides of house. 6). Laundry room - Missing firestop at PT lathe & 2" x 6" pack out wall intersection. Inspector Notes from Inspection 2420 5/16/23: Must be complete prior to Insulation Inspection. Check at Insulation! *** Need to move wall mounted combo detector outside of Master Bedroom to better match location on plan detail. (To cover common area as intended). Inspector Notes from Inspection 2320 4/25/23: Please have the permit box mounted in the front of the property as required (not laying in the garage).
PEP TANK INSTALLATION REQUEST 05/22/2023 APPROVED CSTONE
ALL ROUGH 05/16/2023 APPROVED - AS NOTED RSIMS
Note: 5/16/23: Must be complete prior to Insulation Inspection. Check at Insulation! *** Need to move wall mounted combo detector outside of Master Bedroom to better match location on plan detail. (To cover common area as intended). Inspector Notes from Inspection 2320 4/25/23: Please have the permit box mounted in the front of the property as required (not laying in the garage).
LATH/BRICK/ WATER BARRIER 04/25/2023 APPROVED - AS NOTED RSIMS
Note: 4/25/23: Please have the permit box mounted in the front of the property as required (not laying in the garage).
ELECTRIC-TUG 04/21/2023 APPROVED - AS NOTED BTAYLOR
Note: 4-21-23 1. Emailed FPL at 9:24.
WALL SHEATHING 04/21/2023 APPROVED BTAYLOR
ROOF SHEATHING / BRACES/TIES/DOWN CELL 04/21/2023 APPROVED BTAYLOR
ROOF VALLEY & METAL 04/21/2023 APPROVED BTAYLOR
TIE BEAM / LINTEL 03/20/2023 APPROVED RSIMS
Note: 3/15/2023 - PREVIOUS INSPECTION NOTES 3/15/23: Return inspection! 1). 4 of the window mortar beds are over the maximum 1/2" thickness. (FBC606.3.1) 3/15/2023 - PREVIOUS INSPECTION NOTES 3/15/23: No plans in box for inspection! (107.3.1). Inspection stopped.
TIE BEAM / LINTEL 03/16/2023 Disapproved -FEE REQUIRED RSIMS
Note: 3/15/23: Return inspection! 1). 4 of the window mortar beds are over the maximum 1/2" thickness. (FBC606.3.1) 3/15/2023 - PREVIOUS INSPECTION NOTES 3/15/23: No plans in box for inspection! (107.3.1). Inspection stopped.
TIE BEAM / LINTEL 03/15/2023 Disapproved - NO FEE RSIMS
Note: 3/15/23: No plans in box for inspection! (107.3.1). Inspection stopped.
FOUND SURVEY APPROVED (OFFICE) 03/15/2023 APPROVED TBAKER
U-CROSS CONNECTION 03/15/2023 APPROVED - AS NOTED JHARDING
Note: No irrigation,no cross connections.
MONOLITHIC SLAB 03/07/2023 APPROVED RSIMS
PLUMBING 1ST ROUGH UNDERGROUND 03/06/2023 APPROVED MGIBSON
WATER METER INSTALLATION REQUEST 03/06/2023 APPROVED CSTONE

Review History

Department Status Date In Date Out
MECH COMPLETE 08/29/2023 08/31/2023
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
PLFM COMPLETE 03/14/2023 03/14/2023
Note: Released By: JORDAN MYERS, C.F.M - (386)986-2320 - JMYERS@PALMCOASTGOV.COM Foundation survey shows house outside of Zone A but elevation certificate states structure is inside Zone A. Staff is going to reject the elevation certificate, there is no need to upload another one.
ZON COMPLETE 03/14/2023 03/14/2023
Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM
ENGIN1 COMPLETE 03/14/2023 03/15/2023
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
PLFM COMPLETE 11/17/2022 11/18/2022
Note: Released By: JORDAN MYERS, C.F.M - (386)986-2320 - JMYERS@PALMCOASTGOV.COM The BFE Determination has been accepted. The Revised Site Plan shows the structure outside of the SFHA, no elevation certificates will be required.
ENGIN1 COMPLETE 11/17/2022 11/17/2022
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
SW1 COMPLETE 11/17/2022 11/28/2022
Note: Released By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM
ZON COMPLETE 11/17/2022 11/17/2022
Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM
ZON COMPLETE 09/02/2022 09/02/2022
Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM
PLFM HOLD 09/02/2022 09/02/2022
Note: Held By: JORDAN MYERS, C.F.M - (386)986-2320 - JMYERS@PALMCOASTGOV.COM Staff needs the analysis done by the engineer that resulted in a BFE of 24' in order to do a complete review.
ENGIN1 HOLD 09/02/2022 09/02/2022
Note: Held By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM Sirte benchmark elevation is off from center of road elevations by .8' +/-
CUSVC COMPLETE 09/02/2022 09/07/2022
Note: Released By: LISA ASBILL - - lasbill@palmcoastgov.com
SW1 COMPLETE 09/02/2022 09/13/2022
Note: Released By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM
ENGIN1 HOLD 08/19/2022 08/19/2022
Note: Held By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM Benchmark elevation does not agree with site elevations by .8' Site elevations were chjecked with GPS and ITT as-builts and appear to be fine - the benchmark elevation seems to be off.
SWALE COMPLETE 08/08/2022 11/29/2022
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
PLFM HOLD 08/08/2022 08/08/2022
Note: Held By: JORDAN MYERS, C.F.M - (386)986-2320 - JMYERS@PALMCOASTGOV.COM Please correct Map No. in the Notes on the Survey/Site Plan. According to the Site Plan, there is an unnumbered A Zone on the property. Per 10.02.07.B in the Land Development Code, the Base Flood Elevation must be established by an engineer and submitted to the City for review. Additional comments may apply when the analysis is submitted.
BLD COMPLETE 08/05/2022 08/10/2022
Note: Released By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM
CUSVC COMPLETE 08/05/2022 08/08/2022
Note: Released By: CYNTHIA SCHWEERS - - CSCHWEERS@PALMCOASSTGOV.COM
ELEC COMPLETE 08/05/2022 08/08/2022
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
ENGIN1 COMPLETE 08/05/2022 08/08/2022
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
LOCATE COMPLETE 08/05/2022 08/12/2022
Note: Released By: CANDACE STONE - - CSTONE@PALMCOASTGOV.COM
MECH COMPLETE 08/05/2022 08/09/2022
Note: Released By: CHRIS PISCITELLI - (386)986-3782 - CPISCITELLI@PALMCOASTGOV.COM
SW1 COMPLETE 08/05/2022 08/12/2022
Note: Released By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM
ZON HOLD 08/05/2022 08/08/2022
Note: Held By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM Site Plan Map panel number is incorrect should be 0228E Elevation plan: Please add banding on rigt side of home as home face ROW.

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
CONTRACTOR CHANGE ¤20.00 12/12/2023
SW ENG REINSPECTION 20 ¤20.00 12/12/2023
SW ENG REINSPECTION 20 ¤20.00 12/12/2023
SW ENG REINSPECTION 20 ¤20.00 12/12/2023
SW ENG REINSPECTION 30 ¤30.00 12/12/2023
SW ENG REINSPECTION 30 ¤30.00 12/12/2023
REINSPECTION RESIDENTIAL ¤40.00 12/12/2023
REINSPECTION RESIDENTIAL ¤40.00 12/12/2023
CONNECTION FEES ¤1,166.26 03/03/2023
WATER- TURN ON ¤25.00 03/03/2023
ADJUSTMENT 50% (¤405.07) 03/03/2023
ADMINISTRATIVE RESIDENTIAL ¤30.00 03/03/2023
INSPECTION - RESIDENTIAL ¤607.75 03/03/2023
PLAN REVIEW - RESIDENTIAL ¤172.38 03/03/2023
SW ENG - REVIEW 20 ¤20.00 03/03/2023
SW ENG RES REVIEW 200 ¤200.00 03/03/2023
3% TRANS IMPACT FEE CREDIT (¤52.92) 03/03/2023
SEWER CREDIT (¤850.00) 03/03/2023
SEWER INSPECTION ¤25.00 03/03/2023
SEWER CAPITAL FACILITY ¤5,344.82 03/03/2023
WATER CAPITAL FACILITY FEE ¤3,923.88 03/03/2023
SITE PLAN 30 ¤30.00 03/03/2023
3% FIRE IMPACT FEE CREDIT (¤11.66) 03/03/2023
IMPACT FEE FIRE ¤388.65 03/03/2023
IMPACT FEE PARKS ¤1,455.13 03/03/2023
IMPACT FEE SCHOOL ¤3,600.00 03/03/2023
IMPACT FEE TRANSPORTATION ¤1,764.00 03/03/2023
WATER -IRRIGATION INSPECTION ¤25.00 03/03/2023
3% PARKS IMPACT FEE CREDIT (¤43.65) 03/03/2023
SURCHARGE FS 533.721 ¤2.69 03/03/2023
SURCHARGE - FS 468.631 ¤4.04 03/03/2023
SW ENG - FOUNDATION SURVEY ¤20.00 03/03/2023
SW ENG INSPECTION 80 ¤80.00 03/03/2023
SW ENG PRE APRON ¤30.00 03/03/2023
Fees Total Due: ¤0.00 Total Paid: ¤17,771.30