I want to search for...

Permit #2022080414

Permit Details

Status: COED

Parcel Id: 07-11-31-7027-00400-0090
CONDITIONED SPACE: 2430 sqft
GARAGE: 699 sqft
OPENED PORCH (WITH ROOF) : 600 sqft
Total Square Footage: 3729 sqft
Block: 00400
Subdivision: 2128 - SECTION 27-WYNNFIELD
Job Phone: 386-627-0430
Location Address: 58 WOOD CEDAR DR
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 09/12/2022
NOC: RECORDED
Applicant name: ANNA WIKTORIA LISOWSKI
Owner: KLEBANOV GILEL & OLGA VOLOVAYA H&W

Address

74 LYONRIDGE LANE

SAN MATEO, CA 94402

Lot: 0090
Contracted Stated Job Value: ¤400,000.00
Job Description: Single Family Residence
Type: CN

Contractor

GOLDEN FOX HOME REMODELING, INC
Status Location Address State License Number Phone
ACTIVE

72 HERNANDEZ AVE

PALM COAST, FL 32137

CBC1259266 (Exp: 08/31/2026) 386-627-0430

Sub Contractors

DANIEL J LUSINSKI
Status Location Address Mailing Address State License Number Phone
ACTIVE

389 PALM COAST PARKWAY SW

PALM COAST, FL 32137

#4

PALM COAST, FL 32137

CCC1330133 (Exp: 08/31/2026) 386-338-7926
WILLIAM TODD SIKES
Status Location Address State License Number Phone
ACTIVE

83 PORT ROYAL DR

ST AUGUSTINE, FL 32084

EC0002726 (Exp: 08/31/2026) 904-762-8762
THOMAS A REGULA
Status Location Address State License Number Phone Fax
INACTIVE

11320 PHILLIPS PKWY DRIVE E

JACKSONVILLE, FL 32256

CMC1250075 (Exp: 08/31/2026) 904-278-0339 904-278-0366
JUAN CARLOS GONZALEZ
Status Location Address State License Number
ACTIVE

1328 COUNTY ROAD 308

CRESCENT CITY, FL 32112

RF11067806 (Exp: 08/31/2027)

Inspection History

Type Request Date Result Inspector
BLD - BUILDING FINAL 09/13/2023 FINAL APPROVED JSTEWART
U-CROSS CONNECTION 09/13/2023 APPROVED - AS NOTED LFITZGERALD
Note: has irrigation meter with PVB installed-no cross connection
ROW - STORMWATER FINAL 09/13/2023 APPROVED - AS NOTED FSLADISH
Note: 09/13/23 CORRECTIONS REQUESTED BY PREVIOUS INSPECTOR COMPLETED. At the time of the inspection all minimum city requirements were met. It is the builders responsibiliy to ensure that nothing changes after this Inspection is approved. _________________________________________________________________________________________________________________________ NOTE TO INSPECTOR TALK TO GRADE GUY TOLD HIME THAT ALL THE BARE EARTH IN THE VACANT LOT NEEDS SEED AND STRAW AND IN THE ROAD SIDE SWALE BAHIA GRASS TO MATCH EXISTING
U -UTILITY RESIDENTIAL FINAL 09/13/2023 FINAL APPROVED LFITZGERALD
ROW - FINAL APRON (AFTER POUR) 09/11/2023 APPROVED PFLANAGAN
Note: At the time of the inspection all minimum city requirements were met. It is the builders responsibiliy to ensure that nothing changes after this Inspection is approved.
ROW FIELD SURVEY /GRADING CERTIFICATION 09/11/2023 APPROVED PFLANAGAN
Note: At the time of the inspection all minimum city requirements were met. It is the builders responsibiliy to ensure that nothing changes after this Inspection is approved. ------------------------------------------------------------------------------------ NEED TO RE- DEFINE THE DRAINAGE CONVAYANCE IN THE BACK AND ON THE SIDE. ON THE LEFT SIDE WATER IS IMPACTEING THE HOUSE.
ROW- PROJECT STATUS 09/06/2023 APPROVED - AS NOTED GBERTOLA
Note: NEED TO RE- DEFINE THE DRAINAGE CONVAYANCE IN THE BACK AND ON THE SIDE. ON THE LEFT SIDE WATER IS IMPACTEING THE HOUSE.
ROW- FINAL SURVEY/GRADING CERTIFICATION 08/23/2023 APPROVED PFLANAGAN
Note: At the time of the inspection all minimum city requirements were met. It is the builders responsibiliy to ensure that nothing changes after this Inspection is approved.
ROW FIELD SURVEY /GRADING CERTIFICATION 08/23/2023 Disapproved - NO FEE PFLANAGAN
Note: 1) THE AC UNIT AND BEDS ON THE LEFT SIDE OF HOUSE IS OBSTRUCTING THE WATER FROM FLOWING TO ROAD SIDE SWALE 2) THE WATER IN THE BACK YARD IS FLOWING UP AGAINST THE HOUSE
ELECTRIC - EARLY POWER 06/15/2023 APPROVED - AS NOTED MKRASKI
Note: Emailed FPL @ 11:15AM
ROW- PROJECT STATUS 06/12/2023 APPROVED PFLANAGAN
Note: MEET WITH GRADE GUY ABOUT THE GRADE ON YARD
ROW- PRE-APRON (PRE-POUR) 05/24/2023 APPROVED - AS NOTED FSLADISH
Note: 05/24/23 PIPE IS GOOD. MAKE SURE TO REMOVE ANY LITTLE BIT OF WATER AND MAINTAIN 6" X 6" CULVERT END FOOTER. READY TO POUR. AT THE TIME OF THE INSPECTION CULVERT PIPE IS GOOD IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD DOUBLE CHECK CULVERT ELEVATIONS BEFORE POURING. MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL ________________________________________________________________________________________________________________________ 5/23/2023 - PREVIOUS INSPECTION NOTES 05/232/23 LEFT SIDE CULVERT HAS WASHED IN, PIPE IS FULL OF DIRT. WILL NEED TO REDIG LEFT SIDE MITERED END FOOTER BACK OUT TO 6" X 6" SPECIFICATIONS. PLEASE SEE PHOTO FOR REFERENCE.
ROW- PRE-APRON (PRE-POUR) 05/23/2023 Disapproved -FEE REQUIRED FSLADISH
Note: 05/232/23 LEFT SIDE CULVERT HAS WASHED IN, PIPE IS FULL OF DIRT. WILL NEED TO REDIG LEFT SIDE MITERED END FOOTER BACK OUT TO 6" X 6" SPECIFICATIONS. PLEASE SEE PHOTO FOR REFERENCE.
U - SEWER TIE IN 05/15/2023 APPROVED - AS NOTED MGIBSON
Note: THIS WAS A VIRTUAL INSPECTION
GRAVITY SEWER TEST 05/15/2023 APPROVED MGIBSON
PEP TANK INSTALLATION REQUEST 04/10/2023 APPROVED - AS NOTED TSCHWEERS
Note: 4/11/2023 Gravity sewer no pep tank needed.
INSULATION 03/31/2023 APPROVED MKRASKI
Note: 3/30/2023 - PREVIOUS INSPECTION NOTES 3/30/23 1. Address not visible from road per FBC 319.1 2. Fire foam required @ top plate for range vent (kitchen side) Inspector Notes from Inspection 2320 1. Range hood needs nail plates at top plate on both sides 2. Flat straps need to be installed where 2x4s were cut out for vent 3. Back bathroom shower knee wall needs to be attached to slab Check @ insulation Added window nailing inspection
INSULATION 03/30/2023 Disapproved - NO FEE MKRASKI
Note: 3/30/23 1. Address not visible from road per FBC 319.1 2. Fire foam required @ top plate for range vent (kitchen side) Inspector Notes from Inspection 2320 1. Range hood needs nail plates at top plate on both sides 2. Flat straps need to be installed where 2x4s were cut out for vent 3. Back bathroom shower knee wall needs to be attached to slab Check @ insulation Added window nailing inspection
LATH/BRICK/ WATER BARRIER 03/21/2023 APPROVED - AS NOTED MKRASKI
Note: 1. Range hood needs nail plates at top plate on both sides 2. Flat straps need to be installed where 2x4s were cut out for vent 3. Back bathroom shower knee wall needs to be attached to slab Check @ insulation Added window nailing inspection
ALL ROUGH 03/10/2023 APPROVED - AS NOTED MKRASKI
Note: 1. Range hood needs nail plates at top plate on both sides 2. Flat straps need to be installed where 2x4s were cut out for vent 3. Back bathroom shower knee wall needs to be attached to slab Check @ insulation Added window nailing inspection
ROOF VALLEY & METAL 01/30/2023 APPROVED MKRASKI
ROOF VALLEY & METAL 01/27/2023 CANCELLED BY APPLICANT FWILLIS
Note: 1/26/2023 - PREVIOUS INSPECTION NOTES 1/25/2023 - PREVIOUS INSPECTION NOTES Per phone convo with D. Chardini, it was my understanding the roof had only been dried in, not shingled. Reschedule and have roofer meet inspector on site to verify dry in. 1-26-23 Called Danial at 8: 38 no answer. when we arrived at the site there was no one here for the destructive inspection
ROOF VALLEY & METAL 01/26/2023 Disapproved - NO FEE LMILLER
Note: 1/25/2023 - PREVIOUS INSPECTION NOTES Per phone convo with D. Chardini, it was my understanding the roof had only been dried in, not shingled. Reschedule and have roofer meet inspector on site to verify dry in. 1-26-23 Called Danial at 8: 38 no answer. when we arrived at the site there was no one here for the destructive inspection
ROOF VALLEY & METAL 01/25/2023 Disapproved - NO FEE KSANDOE
Note: Per phone convo with D. Chardini, it was my understanding the roof had only been dried in, not shingled. Reschedule and have roofer meet inspector on site to verify dry in.
ELECTRIC-TUG 01/24/2023 APPROVED - AS NOTED MKRASKI
Note: Emailed FPL @ 1:50 PM
ROOF SHEATHING / BRACES/TIES/DOWN CELL 01/18/2023 APPROVED JWALKER
Note: 1/17/2023 - PREVIOUS INSPECTION NOTES 1/17/23 No new engineering packet onsite stopped inspection 1/3/2023 - PREVIOUS INSPECTION NOTES 12/22/22: INSPECTION STOPPED! NOT READY! *** Framing contractor is still working on framing. **** Roof sheathing bump checked & walked - Approved 1/3/23 Down cells passed. As noted above roof passed and may be covered. 1. The Truss Page 10 of the prints and the engineering packet do not match. Truss on print are lettered T trusses in packet are letter A. 2. The piggy back trusses are missing hold down anchors. 3. Truss T-11 shown on the prints is missing a hold down anchor ans well as the small jack trusses. The wall needs to have anchors as it is part of the support / bearing wall holding the trusses. 4. Truss T-19 shown on the prints is out of allowed plumb tolerance at the front CMU wall. 5. Install hold down strap at the overframing ridge board end where it meets the roof below. 6. Front entry shearwall has not been anchor bolted down to the CMU wall below. 7. MGT anchor rear back room right side of the building needs to be nailed down. Stopped inspection engineering will need to be checked with new engineering packet.
ROOF SHEATHING / BRACES/TIES/DOWN CELL 01/17/2023 Disapproved -FEE REQUIRED MKRASKI
Note: 1/17/23 No new engineering packet onsite stopped inspection 1/3/2023 - PREVIOUS INSPECTION NOTES 12/22/22: INSPECTION STOPPED! NOT READY! *** Framing contractor is still working on framing. **** Roof sheathing bump checked & walked - Approved 1/3/23 Down cells passed. As noted above roof passed and may be covered. 1. The Truss Page 10 of the prints and the engineering packet do not match. Truss on print are lettered T trusses in packet are letter A. 2. The piggy back trusses are missing hold down anchors. 3. Truss T-11 shown on the prints is missing a hold down anchor ans well as the small jack trusses. The wall needs to have anchors as it is part of the support / bearing wall holding the trusses. 4. Truss T-19 shown on the prints is out of allowed plumb tolerance at the front CMU wall. 5. Install hold down strap at the overframing ridge board end where it meets the roof below. 6. Front entry shearwall has not been anchor bolted down to the CMU wall below. 7. MGT anchor rear back room right side of the building needs to be nailed down. Stopped inspection engineering will need to be checked with new engineering packet.
ROOF SHEATHING / BRACES/TIES/DOWN CELL 01/03/2023 Disapproved -FEE REQUIRED JWALKER
Note: 12/22/22: INSPECTION STOPPED! NOT READY! *** Framing contractor is still working on framing. **** Roof sheathing bump checked & walked - Approved 1/3/23 Down cells passed. As noted above roof passed and may be covered. 1. The Truss Page 10 of the prints and the engineering packet do not match. Truss on print are lettered T trusses in packet are letter A. 2. The piggy back trusses are missing hold down anchors. 3. Truss T-11 shown on the prints is missing a hold down anchor ans well as the small jack trusses. The wall needs to have anchors as it is part of the support / bearing wall holding the trusses. 4. Truss T-19 shown on the prints is out of allowed plumb tolerance at the front CMU wall. 5. Install hold down strap at the overframing ridge board end where it meets the roof below. 6. Front entry shearwall has not been anchor bolted down to the CMU wall below. 7. MGT anchor rear back room right side of the building needs to be nailed down. Stopped inspection engineering will need to be checked with new engineering packet.
WALL SHEATHING 12/22/2022 APPROVED RSIMS
ROOF SHEATHING / BRACES/TIES/DOWN CELL 12/22/2022 Disapproved - NO FEE RSIMS
Note: 12/22/22: INSPECTION STOPPED! NOT READY! *** Framing contractor is still working on framing. **** Roof sheathing bump checked & walked - Approved
TIE BEAM / LINTEL 12/05/2022 APPROVED MKRASKI
FOUND SURVEY APPROVED (OFFICE) 11/29/2022 APPROVED TBAKER
MONOLITHIC SLAB 11/16/2022 APPROVED MKRASKI
PLUMBING 1ST ROUGH UNDERGROUND 10/25/2022 APPROVED MGIBSON
WATER METER INSTALLATION REQUEST 09/26/2022 APPROVED CSTONE

Review History

Department Status Date In Date Out
BLD COMPLETE 01/06/2023 01/09/2023
Note: Released By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM
ENGIN1 COMPLETE 11/28/2022 11/29/2022
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
ZON COMPLETE 11/28/2022 11/28/2022
Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM
ZON COMPLETE 08/23/2022 08/23/2022
Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM
BLD COMPLETE 08/23/2022 08/25/2022
Note: Released By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM
ZON HOLD 08/16/2022 08/16/2022
Note: Held By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM Please change location on ac pad on landscape and floor plan to match site plan
SW1 COMPLETE 08/16/2022 08/23/2022
Note: Released By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM
ENGIN1 COMPLETE 08/16/2022 08/16/2022
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
BLD COMPLETE 08/08/2022 08/12/2022
Note: Released By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM
CUSVC COMPLETE 08/08/2022 08/10/2022
Note: Released By: LISA ASBILL - - lasbill@palmcoastgov.com
ELEC COMPLETE 08/08/2022 08/08/2022
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
ENGIN1 COMPLETE 08/08/2022 08/08/2022
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
LOCATE COMPLETE 08/08/2022 08/12/2022
Note: Released By: CANDACE STONE - - CSTONE@PALMCOASTGOV.COM
MECH COMPLETE 08/08/2022 08/09/2022
Note: Released By: CHRIS PISCITELLI - (386)986-3782 - CPISCITELLI@PALMCOASTGOV.COM
SW1 HOLD 08/08/2022 08/15/2022
Note: Held By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM NEED TO MAKE THE LEFT PROPERTY LINE A COMMON
ZON HOLD 08/08/2022 08/09/2022
Note: Held By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM AC pad encroaching in the 5ft utility easement
SWALE COMPLETE 08/08/2022 11/30/2022
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
PLAN REVIEW - REVISION ¤32.50 09/13/2023
REINSPECTION RESIDENTIAL ¤40.00 09/13/2023
REINSPECTION RESIDENTIAL ¤40.00 09/13/2023
SW ENG REINSPECTION 20 ¤20.00 09/13/2023
SW ENG REINSPECTION 20 ¤20.00 09/13/2023
SW ENG REINSPECTION 30 ¤30.00 09/13/2023
SW ENG - REVIEW 20 ¤20.00 09/12/2022
SW ENG RES REVIEW 200 ¤200.00 09/12/2022
3% TRANS IMPACT FEE CREDIT (¤52.92) 09/12/2022
SEWER CREDIT (¤1,147.00) 09/12/2022
SEWER INSPECTION ¤25.00 09/12/2022
SEWER CAPITAL FACILITY ¤4,939.76 09/12/2022
WATER CAPITAL FACILITY FEE ¤3,626.50 09/12/2022
SITE PLAN 30 ¤30.00 09/12/2022
WATER-METER ¤467.09 09/12/2022
WATER- TURN ON ¤25.00 09/12/2022
WATER- TURN ON ¤25.00 09/12/2022
ADJUSTMENT 50% (¤721.00) 09/12/2022
ADMINISTRATIVE RESIDENTIAL ¤30.00 09/12/2022
INSPECTION - RESIDENTIAL ¤1,100.00 09/12/2022
PLAN REVIEW - RESIDENTIAL ¤312.00 09/12/2022
PLAN REVIEW - REVISION ¤32.50 09/12/2022
CONNECTION FEES ¤1,077.88 09/12/2022
3% FIRE IMPACT FEE CREDIT (¤11.66) 09/12/2022
IMPACT FEE FIRE ¤388.65 09/12/2022
IMPACT FEE PARKS ¤1,455.13 09/12/2022
IMPACT FEE SCHOOL ¤3,600.00 09/12/2022
IMPACT FEE TRANSPORTATION ¤1,764.00 09/12/2022
WATER -IRRIGATION INSPECTION ¤25.00 09/12/2022
WATER -IRRIGATION INSPECTION ¤25.00 09/12/2022
3% PARKS IMPACT FEE CREDIT (¤43.65) 09/12/2022
SURCHARGE FS 533.721 ¤4.50 09/12/2022
SURCHARGE - FS 468.631 ¤6.75 09/12/2022
SW ENG - FOUNDATION SURVEY ¤20.00 09/12/2022
SW ENG INSPECTION 80 ¤80.00 09/12/2022
SW ENG PRE APRON ¤30.00 09/12/2022
Fees Total Due: ¤0.00 Total Paid: ¤17,516.03