I want to search for...

Permit #2022080781

Permit Details

Status: FINAL

Parcel Id: 07-11-31-7013-00090-0190
Total Square Footage: 2000 sqft
Block: 00090
Subdivision: 2192 - SECTION 13-BELLE TERRE
Job Phone: 904-200-1339
Location Address: 97 BRESSLER LN
Type: FS - FIRE SPRINKLER WET COMMERCIAL
Issue Date: 11/02/2022
NOC: RECORDED
Applicant name: JOHN CHEEK
Owner: NEJAME JAMAL

Address

97 BRESSLER LANE

PALM COAST, FL 32137

Lot: 0190
Contracted Stated Job Value: ¤9,000.00
Job Description: FIRE SPRINKLER
Type: CN

Contractor

PYE-BARKER FIRE & SAFETY LLC
Status Location Address State License Number Phone
ACTIVE

8936 WESTERN WAY, SUITE 5

JACKSONVILLE, FL 32256

FPC16-000111 (Exp: 06/30/2026) 904-634-7100

Inspection History

Type Request Date Result Inspector
FIRE SPRINKLER FINAL 11/16/2022 FINAL APPROVED LMILLER
Note: 11/15/2022 - PREVIOUS INSPECTION NOTES Record of completion documents are needed to final approve the permit. The documents provided are for yearly testing Please provide the documentation for Record of Completion for the Final inspection per NFPA 1, 13.7.2.2.1 (12) 11-16-22 Record of completion was received and added to the system. Result is Final Approved
FIRE SPRINKLER FINAL 11/15/2022 Disapproved - NO FEE LMILLER
Note: Record of completion documents are needed to final approve the permit. The documents provided are for yearly testing Please provide the documentation for Record of Completion for the Final inspection per NFPA 1, 13.7.2.2.1 (12)
FIRE SPRINKLER 1ST ROUGH 11/15/2022 APPROVED LMILLER
Note: 11/14/2022 - PREVIOUS INSPECTION NOTES 11/9/2022 - PREVIOUS INSPECTION NOTES Need approved plans on site for inspection 107.3 11-14-22 1. Note on plans calls for outside hose connection and there is no FDC for hose connection. 2. First room checked for First rough Sprinkler pipe and sprinkler locations does not match the approved plans (the Master Bedroom calls for 2 sprinklers and only one is insalled. Please revise the plans and have the approved revision on site for inspection. 11-15-22 Approved
FIRE SPRINKLER 1ST ROUGH 11/14/2022 Disapproved -FEE REQUIRED LMILLER
Note: 11/9/2022 - PREVIOUS INSPECTION NOTES Need approved plans on site for inspection 107.3 11-14-22 1. Note on plans calls for outside hose connection and there is no FDC for hose connection. 2. First room checked for First rough Sprinkler pipe and sprinkler locations does not match the approved plans (the Master Bedroom calls for 2 sprinklers and only one is insalled. Please revise the plans and have the approved revision on site for inspection.
FIRE SPRINKLER 1ST ROUGH 11/09/2022 Disapproved -FEE REQUIRED LMILLER
Note: Need approved plans on site for inspection 107.3
FIRE SPRINKLER 2ND RGH HYDROSTATIC PRESS TEST 11/09/2022 APPROVED LMILLER
Note: Hydro only

Review History

Department Status Date In Date Out
FI1 COMPLETE 11/16/2022 11/16/2022
Note: Released By: LEE MILLER - (386)986-3783 - WMILLER@PALMCOASTGOV.COM
FI1 COMPLETE 10/17/2022 10/17/2022
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM A review of FS 633.102 (2) (b) revealked that a Contractor II is able to install piping serving a fire sprinkler system from the "point of service". This being the only remaining review comment, the permit is now approved for issuance.
FI1 HOLD 09/14/2022 09/19/2022
Note: Held By: LEE MILLER - (386)986-3783 - WMILLER@PALMCOASTGOV.COM A separate permit is required for all fire underground work to be performed by a Type V Fire Contractor (Fire underground must be approved prior to approval of the Sprinkler System).
FI1 HOLD 09/13/2022 09/13/2022
Note: Held By: LEE MILLER - (386)986-3783 - WMILLER@PALMCOASTGOV.COM All comments below per the 2020 Florida Fire Prevention Code. And or 2020 FBC Please provide a written response to each comment below in a response letter and provide clouded response changes on plan sheets and add page locations for each response. 1. Floor plan needs to indicate total number of square feet of home. 2. FDC will need to be at the Fire Back Flow Preventer Per AHJ (the riser detail shows a wall mounted FDC, this is not allowed per AHJ). 3. Please submit Material cut sheets for pipe to be used. 4. A separate permit is required for fire underground. (Fire underground must be approved prior to approval of the Sprinkler System).
FI1 HOLD 08/12/2022 08/24/2022
Note: Held By: LEE MILLER - (386)986-3783 - WMILLER@PALMCOASTGOV.COM 1. You are proposing a 13-D Sprinkler System. The system required for this location is a 13-R. Please revise documents for review. 2. Floor plan needs to indicate total number of square feet of home. 3. FDC will need to be at the Fire Back Flow Preventer Per AHJ (the riser detail shows a wall mounted FDC). 4. Please submit Material cut sheets for pipe to be used. 5. A separate permit is required for fire underground. (Fire underground must be approved prior to approval of the Sprinkler System).
UD1 COMPLETE 08/12/2022 08/15/2022
Note: Released By: CHRIS JOHNSON - (386)986-2384 - CJOHNSON@PALMCOASTGOV.COM

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
REINSPECTION - COMMERCIAL ¤60.00 11/14/2022
REINSPECTION - COMMERCIAL ¤60.00 11/11/2022
SURCHARGE FS 533.721 ¤2.00 11/02/2022
SURCHARGE - FS 468.631 ¤2.00 11/02/2022
SW ENG - INSPECTION 20 ¤20.00 11/02/2022
ADJUSTMENT 50% (¤121.95) 11/02/2022
ADMINISTRATIVE - COMMERCIAL ¤75.00 11/02/2022
INSPECTION - FIRE COMMERCIAL ¤65.40 11/02/2022
PLAN REVIEW - COMMERCIAL ¤103.50 11/02/2022
Fees Total Due: ¤0.00 Total Paid: ¤265.95