Permit #2022080865

Permit Details

Status: COED

Parcel Id: 07-11-31-7034-00580-0120
GARAGE: 506 sqft
CONDITIONED SPACE: 1935 sqft
OPENED PORCH (WITH ROOF) : 143 sqft
OPENED PORCH (WITH ROOF) : 45 sqft
Total Square Footage: 2629 sqft
Block: 00580
Subdivision: 2165 - SECTION 34-EASTHAMPTON
Job Phone: 407-580-2657
Location Address: 13 ELLISON LN
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 10/05/2022
NOC: RECORDED
Applicant name: GENE WARREN SLONE
Owner: RIVERA DOMINGO VICENTE & CONSTANZA H&W

Address

174 W LAUREL DR

MARGATE, FL 33063

Lot: 0120
Contracted Stated Job Value: ¤419,601.00
Job Description: single family residence
Type: CN

Contractor

FLORIDA GREEN CONSTRUCTION INC.
Status Location Address State License Number Phone
INACTIVE

870 E RETTA STREET

DELEON SPRINGS, FL 32130

CBC1260957 (Exp: 08/31/2026) 407-580-2657

Sub Contractors

JOHN EDWARD GAMBONE
Status Location Address Mailing Address State License Number Phone
ACTIVE

15 HARGROVE LN

PALM COAST, FL 32137

1G

PALM COAST, FL 32137

EC13006037 (Exp: 08/31/2026) 386-586-9144
ERIC FRANCO
Status Location Address Mailing Address State License Number Phone
INACTIVE

840 DELTONA BLVD

DELTONA, FL 32725

STE F2

DELTONA, FL 32725

CCC1327280 (Exp: 08/31/2026) 386-575-4007
KERRY DWAIN AYLESWORTH II
Status Location Address Mailing Address State License Number Phone
ACTIVE

2820 LEWIS SPEEDWAY

ST AUGUSTINE, FL 32084

STE B

ST AUGUSTINE, FL 32084

CAC1820713 (Exp: 08/31/2026) 904-342-5709
JONATHAN M PEARSON
Status Location Address State License Number Phone Fax
ACTIVE

209 N FORSYTH ST

BUNNELL, FL 32110

CFC1425941 (Exp: 08/31/2026) 386-597-0944 386-437-4996

Inspection History

Type Request Date Result Inspector
BLD - BUILDING FINAL 02/27/2024 FINAL APPROVED RSIMS
Note: 2/26/2024 - PREVIOUS INSPECTION NOTES 2/26/24: * Energy calcs are now matching. 1). The breaker for the Washing machine/laundry outlets was off upon arrival - could not test outlets. 2/22/2024 - PREVIOUS INSPECTION NOTES 1. Energy calculations are not matching the units installed. 2. The washing machine receptable needs to be GFI protected.
BLD - BUILDING FINAL 02/26/2024 Disapproved -FEE REQUIRED RSIMS
Note: 2/26/24: * Energy calcs are now matching. 1). The breaker for the Washing machine/laundry outlets was off upon arrival - could not test outlets. 2/22/2024 - PREVIOUS INSPECTION NOTES 1. Energy calculations are not matching the units installed. 2. The washing machine receptable needs to be GFI protected.
BLD - BUILDING FINAL 02/22/2024 Disapproved - NO FEE JWALKER
Note: 1. Energy calculations are not matching the units installed. 2. The washing machine receptable needs to be GFI protected.
ROW - FINAL APRON (AFTER POUR) 01/17/2024 APPROVED - AS NOTED FSLADISH
Note: 1/17/24 PIPE IS .002 HUNDRETHS BACK PITCHED, CUTS MADE. CULVERT CLEAR. HOT PATCH COMPLETED. At the time of the inspection all minimum city requirements were met. It is the builders responsibiliy to ensure that nothing changes after this Inspection is approved. ______________________________________________________________________________________________________________________ 12/12/2023 - PREVIOUS INSPECTION NOTES 12/12/23 RIGHT SIDE MITER END IS NOT WITHIN TOLERENCE AS NOTED IN PRE POUR NOTES 12/5/23 *LOW SPOT IN FRONT RIGHT MARKED WITH WHITE PAINT AND HIGH SPOT IN SWALE WHERE PROPERTY LINE MUST MATCH ADJACENT LOT GRADE. APPROVING THIS INSPECTION AS NOTED PLEASE MAKE ADJUSTMENTS BEFORE FINAL _______________________________________I 10/26/23 MET WITH CM AND WE SET PIPE TO TOLERANCE. PIPE IS GOOD OTHER CORRECTIONS MADE. READY TO POUR AT THE TIME OF THIS INSPECTION. AT THE TIME OF THE INSPECTION CULVERT PIPE IS GOOD IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD DOUBLE CHECK CULVERT ELEVATIONS BEFORE POURING. MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL 10/25/2023 - PREVIOUS INSPECTION NOTES 10/245/23 CULVERT PIPE IS OUT OF TOLERANCE. SPOKE TO CM AND WILL TRY TO MEET HIM ON SITE TOMORROW TO GET PIPE SET CORRECTLY. _________________________________________________________________________________________________________________________ 10/24/2023 - PREVIOUS INSPECTION NOTES 10/24/23 CULVERT PIPE NEEDS TO BE 8' FROM ROAD EDGE TO CENTER OF THE PIPE AT MITERED END. BOTH ENDS ARE OUT OF TOLERANCE, IF YOU LOOK AT THE PHOTO OF THE PIPE LENGTHWISE AND LOOK DOWN TO THE NEXT DRIVEWAY CULVERT PIPE YOU CAN SEE IT IS OFF TO LEFT OF CENTER. NEED TO HAVE A MINIMUM OF 5" OF CONCRETE OVER CULVERT PIPE RIGHT SIDE IS NOT AT THE MINIMUM. ALL CHUNKS OF ASPHALT NEED TO BE REMOVED FROM THE APRON POUR AREA. YOU MUST REMOVE THE FORM BOARD FROM ON TOP OF THE ROAD TO INSIDE THE APRON AT THE ROAD EDGE AND MAKE SURE YOU HAVE A MINIMUM OF 6" OF COCRETE AT THE APRON ROAD EDGE. SEE PHOTOS. ***10/24/23- contractor needs inspection before 10:30 am please
U -UTILITY RESIDENTIAL FINAL 12/19/2023 FINAL APPROVED JHARDING
U-CROSS CONNECTION 12/19/2023 APPROVED - AS NOTED JHARDING
Note: No cross connections.
ROW - FINAL APRON (AFTER POUR) 12/12/2023 Disapproved - NO FEE TPOLACEK
Note: 12/12/23 RIGHT SIDE MITER END IS NOT WITHIN TOLERENCE AS NOTED IN PRE POUR NOTES 12/5/23 *LOW SPOT IN FRONT RIGHT MARKED WITH WHITE PAINT AND HIGH SPOT IN SWALE WHERE PROPERTY LINE MUST MATCH ADJACENT LOT GRADE. APPROVING THIS INSPECTION AS NOTED PLEASE MAKE ADJUSTMENTS BEFORE FINAL _______________________________________I 10/26/23 MET WITH CM AND WE SET PIPE TO TOLERANCE. PIPE IS GOOD OTHER CORRECTIONS MADE. READY TO POUR AT THE TIME OF THIS INSPECTION. AT THE TIME OF THE INSPECTION CULVERT PIPE IS GOOD IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD DOUBLE CHECK CULVERT ELEVATIONS BEFORE POURING. MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL 10/25/2023 - PREVIOUS INSPECTION NOTES 10/245/23 CULVERT PIPE IS OUT OF TOLERANCE. SPOKE TO CM AND WILL TRY TO MEET HIM ON SITE TOMORROW TO GET PIPE SET CORRECTLY. _________________________________________________________________________________________________________________________ 10/24/2023 - PREVIOUS INSPECTION NOTES 10/24/23 CULVERT PIPE NEEDS TO BE 8' FROM ROAD EDGE TO CENTER OF THE PIPE AT MITERED END. BOTH ENDS ARE OUT OF TOLERANCE, IF YOU LOOK AT THE PHOTO OF THE PIPE LENGTHWISE AND LOOK DOWN TO THE NEXT DRIVEWAY CULVERT PIPE YOU CAN SEE IT IS OFF TO LEFT OF CENTER. NEED TO HAVE A MINIMUM OF 5" OF CONCRETE OVER CULVERT PIPE RIGHT SIDE IS NOT AT THE MINIMUM. ALL CHUNKS OF ASPHALT NEED TO BE REMOVED FROM THE APRON POUR AREA. YOU MUST REMOVE THE FORM BOARD FROM ON TOP OF THE ROAD TO INSIDE THE APRON AT THE ROAD EDGE AND MAKE SURE YOU HAVE A MINIMUM OF 6" OF COCRETE AT THE APRON ROAD EDGE. SEE PHOTOS. ***10/24/23- contractor needs inspection before 10:30 am please
ROW - STORMWATER FINAL 12/12/2023 APPROVED TPOLACEK
Note: 12/12/23 At the time of the inspection all minimum city requirements were met. It is the builders responsibiliy to ensure that nothing changes after this Inspection is approved. 12/5/23 *LOW SPOT IN FRONT RIGHT MARKED WITH WHITE PAINT AND HIGH SPOT IN SWALE WHERE PROPERTY LINE MUST MATCH ADJACENT LOT GRADE. APPROVING THIS INSPECTION AS NOTED PLEASE MAKE ADJUSTMENTS BEFORE FINAL _______________________________________I 10/26/23 MET WITH CM AND WE SET PIPE TO TOLERANCE. PIPE IS GOOD OTHER CORRECTIONS MADE. READY TO POUR AT THE TIME OF THIS INSPECTION. AT THE TIME OF THE INSPECTION CULVERT PIPE IS GOOD IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD DOUBLE CHECK CULVERT ELEVATIONS BEFORE POURING. MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL 10/25/2023 - PREVIOUS INSPECTION NOTES 10/245/23 CULVERT PIPE IS OUT OF TOLERANCE. SPOKE TO CM AND WILL TRY TO MEET HIM ON SITE TOMORROW TO GET PIPE SET CORRECTLY. _________________________________________________________________________________________________________________________ 10/24/2023 - PREVIOUS INSPECTION NOTES 10/24/23 CULVERT PIPE NEEDS TO BE 8' FROM ROAD EDGE TO CENTER OF THE PIPE AT MITERED END. BOTH ENDS ARE OUT OF TOLERANCE, IF YOU LOOK AT THE PHOTO OF THE PIPE LENGTHWISE AND LOOK DOWN TO THE NEXT DRIVEWAY CULVERT PIPE YOU CAN SEE IT IS OFF TO LEFT OF CENTER. NEED TO HAVE A MINIMUM OF 5" OF CONCRETE OVER CULVERT PIPE RIGHT SIDE IS NOT AT THE MINIMUM. ALL CHUNKS OF ASPHALT NEED TO BE REMOVED FROM THE APRON POUR AREA. YOU MUST REMOVE THE FORM BOARD FROM ON TOP OF THE ROAD TO INSIDE THE APRON AT THE ROAD EDGE AND MAKE SURE YOU HAVE A MINIMUM OF 6" OF COCRETE AT THE APRON ROAD EDGE. SEE PHOTOS. ***10/24/23- contractor needs inspection before 10:30 am please
ROW- FINAL SURVEY/GRADING CERTIFICATION 12/05/2023 APPROVED - AS NOTED TPOLACEK
Note: _______________________________________I 10/26/23 MET WITH CM AND WE SET PIPE TO TOLERANCE. PIPE IS GOOD OTHER CORRECTIONS MADE. READY TO POUR AT THE TIME OF THIS INSPECTION. AT THE TIME OF THE INSPECTION CULVERT PIPE IS GOOD IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD DOUBLE CHECK CULVERT ELEVATIONS BEFORE POURING. MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL 10/25/2023 - PREVIOUS INSPECTION NOTES 10/245/23 CULVERT PIPE IS OUT OF TOLERANCE. SPOKE TO CM AND WILL TRY TO MEET HIM ON SITE TOMORROW TO GET PIPE SET CORRECTLY. _________________________________________________________________________________________________________________________ 10/24/2023 - PREVIOUS INSPECTION NOTES 10/24/23 CULVERT PIPE NEEDS TO BE 8' FROM ROAD EDGE TO CENTER OF THE PIPE AT MITERED END. BOTH ENDS ARE OUT OF TOLERANCE, IF YOU LOOK AT THE PHOTO OF THE PIPE LENGTHWISE AND LOOK DOWN TO THE NEXT DRIVEWAY CULVERT PIPE YOU CAN SEE IT IS OFF TO LEFT OF CENTER. NEED TO HAVE A MINIMUM OF 5" OF CONCRETE OVER CULVERT PIPE RIGHT SIDE IS NOT AT THE MINIMUM. ALL CHUNKS OF ASPHALT NEED TO BE REMOVED FROM THE APRON POUR AREA. YOU MUST REMOVE THE FORM BOARD FROM ON TOP OF THE ROAD TO INSIDE THE APRON AT THE ROAD EDGE AND MAKE SURE YOU HAVE A MINIMUM OF 6" OF COCRETE AT THE APRON ROAD EDGE. SEE PHOTOS. ***10/24/23- contractor needs inspection before 10:30 am please
ROW FIELD SURVEY /GRADING CERTIFICATION 12/05/2023 APPROVED - AS NOTED TPOLACEK
Note: 12/5/23 *LOW SPOT IN FRONT RIGHT MARKED WITH WHITE PAINT AND HIGH SPOT IN SWALE WHERE PROPERTY LINE MUST MATCH ADJACENT LOT GRADE. APPROVING THIS INSPECTION AS NOTED PLEASE MAKE ADJUSTMENTS BEFORE FINAL _______________________________________I 10/26/23 MET WITH CM AND WE SET PIPE TO TOLERANCE. PIPE IS GOOD OTHER CORRECTIONS MADE. READY TO POUR AT THE TIME OF THIS INSPECTION. AT THE TIME OF THE INSPECTION CULVERT PIPE IS GOOD IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD DOUBLE CHECK CULVERT ELEVATIONS BEFORE POURING. MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL 10/25/2023 - PREVIOUS INSPECTION NOTES 10/245/23 CULVERT PIPE IS OUT OF TOLERANCE. SPOKE TO CM AND WILL TRY TO MEET HIM ON SITE TOMORROW TO GET PIPE SET CORRECTLY. _________________________________________________________________________________________________________________________ 10/24/2023 - PREVIOUS INSPECTION NOTES 10/24/23 CULVERT PIPE NEEDS TO BE 8' FROM ROAD EDGE TO CENTER OF THE PIPE AT MITERED END. BOTH ENDS ARE OUT OF TOLERANCE, IF YOU LOOK AT THE PHOTO OF THE PIPE LENGTHWISE AND LOOK DOWN TO THE NEXT DRIVEWAY CULVERT PIPE YOU CAN SEE IT IS OFF TO LEFT OF CENTER. NEED TO HAVE A MINIMUM OF 5" OF CONCRETE OVER CULVERT PIPE RIGHT SIDE IS NOT AT THE MINIMUM. ALL CHUNKS OF ASPHALT NEED TO BE REMOVED FROM THE APRON POUR AREA. YOU MUST REMOVE THE FORM BOARD FROM ON TOP OF THE ROAD TO INSIDE THE APRON AT THE ROAD EDGE AND MAKE SURE YOU HAVE A MINIMUM OF 6" OF COCRETE AT THE APRON ROAD EDGE. SEE PHOTOS. ***10/24/23- contractor needs inspection before 10:30 am please
ELECTRIC - EARLY POWER 11/21/2023 APPROVED - AS NOTED KSANDOE
Note: Emailed FPL @ 1425. Release Power
ROW- PRE-APRON (PRE-POUR) 10/26/2023 APPROVED - AS NOTED FSLADISH
Note: 10/26/23 MET WITH CM AND WE SET PIPE TO TOLERANCE. PIPE IS GOOD OTHER CORRECTIONS MADE. READY TO POUR AT THE TIME OF THIS INSPECTION. AT THE TIME OF THE INSPECTION CULVERT PIPE IS GOOD IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD DOUBLE CHECK CULVERT ELEVATIONS BEFORE POURING. MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL 10/25/2023 - PREVIOUS INSPECTION NOTES 10/245/23 CULVERT PIPE IS OUT OF TOLERANCE. SPOKE TO CM AND WILL TRY TO MEET HIM ON SITE TOMORROW TO GET PIPE SET CORRECTLY. _________________________________________________________________________________________________________________________ 10/24/2023 - PREVIOUS INSPECTION NOTES 10/24/23 CULVERT PIPE NEEDS TO BE 8' FROM ROAD EDGE TO CENTER OF THE PIPE AT MITERED END. BOTH ENDS ARE OUT OF TOLERANCE, IF YOU LOOK AT THE PHOTO OF THE PIPE LENGTHWISE AND LOOK DOWN TO THE NEXT DRIVEWAY CULVERT PIPE YOU CAN SEE IT IS OFF TO LEFT OF CENTER. NEED TO HAVE A MINIMUM OF 5" OF CONCRETE OVER CULVERT PIPE RIGHT SIDE IS NOT AT THE MINIMUM. ALL CHUNKS OF ASPHALT NEED TO BE REMOVED FROM THE APRON POUR AREA. YOU MUST REMOVE THE FORM BOARD FROM ON TOP OF THE ROAD TO INSIDE THE APRON AT THE ROAD EDGE AND MAKE SURE YOU HAVE A MINIMUM OF 6" OF COCRETE AT THE APRON ROAD EDGE. SEE PHOTOS. ***10/24/23- contractor needs inspection before 10:30 am please
ROW- PRE-APRON (PRE-POUR) 10/25/2023 Disapproved - NO FEE FSLADISH
Note: 10/245/23 CULVERT PIPE IS OUT OF TOLERANCE. SPOKE TO CM AND WILL TRY TO MEET HIM ON SITE TOMORROW TO GET PIPE SET CORRECTLY. _________________________________________________________________________________________________________________________ 10/24/2023 - PREVIOUS INSPECTION NOTES 10/24/23 CULVERT PIPE NEEDS TO BE 8' FROM ROAD EDGE TO CENTER OF THE PIPE AT MITERED END. BOTH ENDS ARE OUT OF TOLERANCE, IF YOU LOOK AT THE PHOTO OF THE PIPE LENGTHWISE AND LOOK DOWN TO THE NEXT DRIVEWAY CULVERT PIPE YOU CAN SEE IT IS OFF TO LEFT OF CENTER. NEED TO HAVE A MINIMUM OF 5" OF CONCRETE OVER CULVERT PIPE RIGHT SIDE IS NOT AT THE MINIMUM. ALL CHUNKS OF ASPHALT NEED TO BE REMOVED FROM THE APRON POUR AREA. YOU MUST REMOVE THE FORM BOARD FROM ON TOP OF THE ROAD TO INSIDE THE APRON AT THE ROAD EDGE AND MAKE SURE YOU HAVE A MINIMUM OF 6" OF COCRETE AT THE APRON ROAD EDGE. SEE PHOTOS. ***10/24/23- contractor needs inspection before 10:30 am please
ROW- PRE-APRON (PRE-POUR) 10/24/2023 Disapproved -FEE REQUIRED FSLADISH
Note: 10/24/23 CULVERT PIPE NEEDS TO BE 8' FROM ROAD EDGE TO CENTER OF THE PIPE AT MITERED END. BOTH ENDS ARE OUT OF TOLERANCE, IF YOU LOOK AT THE PHOTO OF THE PIPE LENGTHWISE AND LOOK DOWN TO THE NEXT DRIVEWAY CULVERT PIPE YOU CAN SEE IT IS OFF TO LEFT OF CENTER. NEED TO HAVE A MINIMUM OF 5" OF CONCRETE OVER CULVERT PIPE RIGHT SIDE IS NOT AT THE MINIMUM. ALL CHUNKS OF ASPHALT NEED TO BE REMOVED FROM THE APRON POUR AREA. YOU MUST REMOVE THE FORM BOARD FROM ON TOP OF THE ROAD TO INSIDE THE APRON AT THE ROAD EDGE AND MAKE SURE YOU HAVE A MINIMUM OF 6" OF COCRETE AT THE APRON ROAD EDGE. SEE PHOTOS.
U - SEWER TIE IN 09/08/2023 APPROVED MGIBSON
GRAVITY SEWER TEST 09/08/2023 APPROVED MGIBSON
PEP TANK INSTALLATION REQUEST 08/21/2023 APPROVED CBOWERMASTER
Note: 8/15/2023 10:29:31 AM- PREVIOUS INSPECTION NOTES dumpster in the way
PEP TANK INSTALLATION REQUEST 08/14/2023 Disapproved -FEE REQUIRED CBOWERMASTER
Note: dumpster in the way
LATH/BRICK/ WATER BARRIER 08/02/2023 APPROVED RSIMS
Note: 7/31/2023 - PREVIOUS INSPECTION NOTES 7/31/23: 1). Right side: install wire lath at hole in cinderblock for low voltage wires. 2). Left side: Install wire lath at holes in cinderblock for Hose Bibb and (2) electrical wires. ** Also, please clean up overgrown weeds around the property before the next inspection. Per Code Enforcement regulations, grass/weeds cannot exceed 3" in height.
LATH/BRICK/ WATER BARRIER 07/31/2023 Disapproved - NO FEE RSIMS
Note: 7/31/23: 1). Right side: install wire lath at hole in cinderblock for low voltage wires. 2). Left side: Install wire lath at holes in cinderblock for Hose Bibb and (2) electrical wires. ** Also, please clean up overgrown weeds around the property before the next inspection. Per Code Enforcement regulations, grass/weeds cannot exceed 3" in height.
INSULATION 07/19/2023 APPROVED BTAYLOR
Note: Inspector Notes from Inspection 2420 7-12-23 1. Need new paperwork with duct layout. The way its installed does not match paperwork.
ALL ROUGH 07/12/2023 APPROVED - AS NOTED BTAYLOR
Note: 7-12-23 1. Need new paperwork with duct layout. The way its installed does not match paperwork.
ROOF VALLEY & METAL 04/13/2023 APPROVED RSIMS
WALL SHEATHING 03/29/2023 APPROVED RSIMS
ROOF SHEATHING / BRACES/TIES/DOWN CELL 03/29/2023 APPROVED - AS NOTED RSIMS
Note: 3/29/23: Check at next inspection! 1). Truss 8 is missing web bracing. (marked on MiTek & truss plan). 2). 2 Ply Truss 23 needs to be nailed together more securely & per MiTek requirements.
TIE BEAM / LINTEL 12/27/2022 APPROVED JWALKER
FOUND SURVEY APPROVED (OFFICE) 12/07/2022 APPROVED TBAKER
MONOLITHIC SLAB 11/28/2022 APPROVED KSANDOE
PLUMBING 1ST ROUGH UNDERGROUND 11/08/2022 APPROVED MGIBSON
ELECTRIC TEMP POLE 10/31/2022 APPROVED RSIMS
Note: 10/31/2022: FPL notified at @ 09:34.
WATER METER INSTALLATION REQUEST 10/31/2022 APPROVED CSTONE

Review History

Department Status Date In Date Out
MECH COMPLETE 01/26/2024 01/29/2024
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
ENGIN1 COMPLETE 09/15/2023 09/18/2023
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
SW1 COMPLETE 09/15/2023 09/21/2023
Note: Released By: EDWARD MADISON - (386)986-4770 - EMADISON@PALMCOASTGOV.COM
ZON COMPLETE 09/15/2023 09/15/2023
Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM
ENGIN1 COMPLETE 12/07/2022 12/07/2022
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
ZON COMPLETE 12/07/2022 12/07/2022
Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM
BLD COMPLETE 09/19/2022 09/20/2022
Note: Released By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM
SWALE COMPLETE 09/13/2022 12/05/2022
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
ZON COMPLETE 09/12/2022 09/13/2022
Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM
ENGIN1 COMPLETE 09/12/2022 09/13/2022
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
BLD HOLD 09/12/2022 09/13/2022
Note: Held By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM All comments below per the 2020 Florida Building Code PLAN REVIEW COMMENTS: 1. Provide a completed City of Palm Coast Roofing Worksheet.
SW1 COMPLETE 09/12/2022 09/19/2022
Note: Released By: ROBERT GROSS - (386)986-4769 - RGROSS@PALMCOASTGOV.COM
ENGIN1 HOLD 08/30/2022 08/30/2022
Note: Held By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM Need acceptable site benchmark.
BLD HOLD 08/30/2022 08/30/2022
Note: Held By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM All comments below per the 2020 Florida Building Code PLAN REVIEW COMMENTS: 1. Provide a completed City of Palm Coast Roofing Worksheet.
ZON HOLD 08/30/2022 08/30/2022
Note: Held By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM REPEAT COMMENTS: Must have a total of four shrubs along each side after wrapping corners. PLAN STILL DOES NOT HAVE 4 ON EACH SIDE. Landscape plan must state sod type and if irrigation will be installed Landscape plan must list all tree types, shrubs types and gallon sizes YOUR PERMIT CORRECTION SHEET STATES THIS INFORMATION IS ON PAGE 2 OF THE LANDSCAPE PLAN, HOWEVER THERE WAS NO PAGE 2 SUBMITTED.
SW1 HOLD 08/30/2022 09/07/2022
Note: Held By: EDWARD MADISON - - EMADISON@PALMCOASTGOV.COM SITE BENCH MARK NEEDS TO BE A NAIL IN DISK, FIRE HYDRANT, NAIL IN POWER POLE, MAN HOLE COVER.
BLD HOLD 08/15/2022 08/16/2022
Note: Held By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM All comments below per the 2020 Florida Building Code PLAN REVIEW COMMENTS: 1. Provide a completed City of Palm Coast Roofing Worksheet.
CUSVC COMPLETE 08/15/2022 08/16/2022
Note: Released By: LISA ASBILL - - lasbill@palmcoastgov.com
ELEC COMPLETE 08/15/2022 08/16/2022
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
ENGIN1 HOLD 08/15/2022 08/16/2022
Note: Held By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM Iron rods are unacceptable as site benchmarks. Please use a nail in a utility pole, manhole cover, nail in asphalt or other approved method. See informational sheet.
LOCATE COMPLETE 08/15/2022 08/18/2022
Note: Released By: CANDACE STONE - - CSTONE@PALMCOASTGOV.COM
MECH COMPLETE 08/15/2022 08/16/2022
Note: Released By: CHRIS PISCITELLI - (386)986-3782 - CPISCITELLI@PALMCOASTGOV.COM
SW1 HOLD 08/15/2022 08/22/2022
Note: Held By: ROBERT GROSS - (386)986-4769 - RGROSS@PALMCOASTGOV.COM See Checklist dated 8/22/22. BM Needs to be a Nail in Disk or Fire hydrant. Nail in pole will be accepted if no other means are possible.
ZON HOLD 08/15/2022 08/17/2022
Note: Held By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM Rear lanai missing on landscape plan. Layout must match plans and site plan. Must have a total of four shrubs along each side after wrapping corners Landscape plan must state sod type and if irrigation will be installed Landscape plan must list all tree types, shrubs types and gallon sizes

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
REINSPECTION RESIDENTIAL ¤40.00 02/27/2024
SW ENG REINSPECTION 30 ¤30.00 12/04/2023
UTILITY PEP REINSPECTION ¤40.00 12/04/2023
SEWER CREDIT (¤1,342.00) 10/05/2022
SEWER INSPECTION ¤25.00 10/05/2022
SEWER CAPITAL FACILITY ¤4,939.76 10/05/2022
WATER CAPITAL FACILITY FEE ¤3,626.50 10/05/2022
SITE PLAN 30 ¤30.00 10/05/2022
SW ENG - REVIEW 20 ¤20.00 10/05/2022
SW ENG RES REVIEW 200 ¤200.00 10/05/2022
3% TRANS IMPACT FEE CREDIT (¤52.92) 10/05/2022
WATER-METER ¤467.09 10/05/2022
WATER- TURN ON ¤25.00 10/05/2022
WATER- TURN ON ¤25.00 10/05/2022
ADJUSTMENT 50% (¤756.30) 10/05/2022
ADMINISTRATIVE RESIDENTIAL ¤30.00 10/05/2022
INSPECTION - RESIDENTIAL ¤1,155.00 10/05/2022
PLAN REVIEW - RESIDENTIAL ¤327.60 10/05/2022
CONNECTION FEES ¤1,077.88 10/05/2022
3% FIRE IMPACT FEE CREDIT (¤11.66) 10/05/2022
IMPACT FEE FIRE ¤388.65 10/05/2022
IMPACT FEE PARKS ¤1,455.13 10/05/2022
IMPACT FEE SCHOOL ¤3,600.00 10/05/2022
IMPACT FEE TRANSPORTATION ¤1,764.00 10/05/2022
WATER -IRRIGATION INSPECTION ¤25.00 10/05/2022
WATER -IRRIGATION INSPECTION ¤25.00 10/05/2022
3% PARKS IMPACT FEE CREDIT (¤43.65) 10/05/2022
SURCHARGE FS 533.721 ¤4.70 10/05/2022
SURCHARGE - FS 468.631 ¤7.06 10/05/2022
SW ENG - FOUNDATION SURVEY ¤20.00 10/05/2022
SW ENG INSPECTION 80 ¤80.00 10/05/2022
SW ENG PRE APRON ¤30.00 10/05/2022
Fees Total Due: ¤0.00 Total Paid: ¤17,251.84