I want to search for...
Permit #2022081153
Permit Details
Status: COED
| Parcel Id: 07-11-31-7025-00650-0140 |
| CONDITIONED SPACE: 1555 sqft |
| GARAGE: 434 sqft |
| OPENED PORCH (WITH ROOF) : 112 sqft |
| OPENED PORCH (WITH ROOF) : 100 sqft |
| Total Square Footage: 2201 sqft |
| Block: 00650 |
| Subdivision: 2189 - SECTION 25-PINE GROVE |
| Job Phone: 832-726-2202 |
| Location Address: 43 PATUXENT LN |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 10/13/2022 |
| NOC: RECORDED |
| Applicant name: JONATHON AMBAR |
| Owner: CASPIAN PERFORMANCE GROUP LLC |
|
Address 1802 N ALFAYA TRL, STE 162 ORLANDO, FL 32826 |
| Lot: 0140 |
| Contracted Stated Job Value: ¤131,500.00 |
| Job Description: SINGLE FAMILY RESIDENCE |
| Type: CN |
Contractor
CASPIAN HOMES, LLC
| Status | Location Address | Mailing Address | State License Number | Phone |
| ACTIVE |
1802 N ALAFAYA TRAIL ORLANDO, FL 32826 |
SUITE 162 ORLANDO, FL 32826 |
CBC1264918 (Exp: 08/31/2026) | 832-726-2202 |
Sub Contractors
TERRY BRICE DICKERSON
| Status | Location Address | State License Number | Phone |
| ACTIVE |
4300 ST JOHN'S PARKWAY ALPHARETTA, GA 30009 |
CCC1326209 (Exp: 08/31/2026) | 407-548-6733 |
JONATHAN M PEARSON
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
209 N FORSYTH ST BUNNELL, FL 32110 |
CFC1425941 (Exp: 08/31/2026) | 386-597-0944 | 386-437-4996 |
DAVID SCOTT MORRIS
| Status | Location Address | State License Number | Phone |
| INACTIVE |
63 LEIDEL DR PALM COAST, FL 32137 |
ER13015750 (Exp: 08/31/2026) | 386-569-7262 |
ROBERT MICHAEL RENNER
| Status | Location Address | State License Number | Phone |
| ACTIVE |
531 CODISCO WAY SANFORD, FL 32771 |
CAC051477 (Exp: 08/31/2026) | 407-333-2665 |
Inspection History
| Type | Request Date | Result | Inspector |
| BLD - BUILDING FINAL | 07/28/2023 | FINAL APPROVED | KSANDOE |
| Note: New inspection due to canceled inspection 7/19/2023 - PREVIOUS INSPECTION NOTES 7/18/7/19/23 1. No insualtion report, or blower door test report 2. T-stat wire needs to be sealed @ ceiling in AHU closet 3. Energy cals do not match 4. No attic access door 5. Slab is damaged behind water heater exposing water lines, slab needs to be repaired 6. AHU has wrong size breaker installed on unit and in panel 2023 - PREVIOUS INSPECTION NOTES 1. Large hole where Cat5 comes through wall @ meter mail needs to be sealed 2. Meter main breaker is not labeled 3. Large holes in stucco by ODU Stopped inspection outside | |||
| BLD - BUILDING FINAL | 07/24/2023 | CANCELLED BY APPLICANT | WEB |
| Note: 7/19/2023 - PREVIOUS INSPECTION NOTES 7/18/7/19/23 1. No insualtion report, or blower door test report 2. T-stat wire needs to be sealed @ ceiling in AHU closet 3. Energy cals do not match 4. No attic access door 5. Slab is damaged behind water heater exposing water lines, slab needs to be repaired 6. AHU has wrong size breaker installed on unit and in panel 2023 - PREVIOUS INSPECTION NOTES 1. Large hole where Cat5 comes through wall @ meter mail needs to be sealed 2. Meter main breaker is not labeled 3. Large holes in stucco by ODU Stopped inspection outside | |||
| BLD - BUILDING FINAL | 07/19/2023 | Disapproved -FEE REQUIRED | MKRASKI |
| Note: 7/18/7/19/23 1. No insualtion report, or blower door test report 2. T-stat wire needs to be sealed @ ceiling in AHU closet 3. Energy cals do not match 4. No attic access door 5. Slab is damaged behind water heater exposing water lines, slab needs to be repaired 6. AHU has wrong size breaker installed on unit and in panel 2023 - PREVIOUS INSPECTION NOTES 1. Large hole where Cat5 comes through wall @ meter mail needs to be sealed 2. Meter main breaker is not labeled 3. Large holes in stucco by ODU Stopped inspection outside | |||
| BLD - BUILDING FINAL | 07/18/2023 | Disapproved - NO FEE | MKRASKI |
| Note: 1. Large hole where Cat5 comes through wall @ meter mail needs to be sealed 2. Meter main breaker is not labeled 3. Large holes in stucco by ODU Stopped inspection outside | |||
| U-CROSS CONNECTION | 07/18/2023 | APPROVED - AS NOTED | LFITZGERALD |
| Note: no irrigation-no cross connection | |||
| ROW - FINAL APRON (AFTER POUR) | 07/18/2023 | APPROVED | FSLADISH |
| Note: 7/18/23 PIPE IS GOOD. CUTS MADE. CULVERT CLEAR. LOOKED GOOD AT THE TIME OF THIS INSPECTION ____________________________________________________________________________________________________________________________ 7/12/2023 - PREVIOUS INSPECTION NOTES | |||
| ROW - STORMWATER FINAL | 07/18/2023 | FINAL APPROVED | FSLADISH |
| Note: 07/18/23 SEE PREVIOUS NOTES WITH REGARD TO LEANING FENCE AND DEBRIS. CORRECTIONS MADE. LOOKED GOOD AT THE TIME OF THIS FINAL ROW INSPECTION. ________________________________________________________________________________________________________________________ 7/12/2023 - PREVIOUS INSPECTION NOTES 07/11/23 NEED TO REMOVE BARK MULCH IN THE RIGHT SIDE DRAINAGE CONVEYANCE AND PUT SOD WHERE IT IS WHITELINED. NOTING THAT THERE IS AN AREA IN BACK WHERE REAR PROPERY OWNERS FENCE IS LEANING ONTO THIS PROPERTY. APPEARS IF THE DEBIS IS REMOVED THE FENCE WILL COLLAPSE | |||
| U -UTILITY RESIDENTIAL FINAL | 07/12/2023 | FINAL APPROVED | LFITZGERALD |
| ROW - STORMWATER FINAL | 07/12/2023 | CANCELLED BY APPLICANT | FSLADISH |
| Note: 07/11/23 NEED TO REMOVE BARK MULCH IN THE RIGHT SIDE DRAINAGE CONVEYANCE AND PUT SOD WHERE IT IS WHITELINED. NOTING THAT THERE IS AN AREA IN BACK WHERE REAR PROPERY OWNERS FENCE IS LEANING ONTO THIS PROPERTY. APPEARS IF THE DEBIS IS REMOVED THE FENCE WILL COLLAPSE | |||
| ROW - FINAL APRON (AFTER POUR) | 07/12/2023 | CANCELLED BY APPLICANT | FSLADISH |
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 07/11/2023 | APPROVED | FSLADISH |
| Note: Inspector Notes from Inspection 9270 06/02/23 PIPE IS GOOD. LOOKED GOOD AT TIME OF INSPECTION. READY TO POUR. AT THE TIME OF THE INSPECTION CULVERT PIPE IS GOOD IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD DOUBLE CHECK CULVERT ELEVATIONS BEFORE POURING. MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL | |||
| ROW FIELD SURVEY /GRADING CERTIFICATION | 07/11/2023 | APPROVED | FSLADISH |
| Note: 07/11/23 NEED TO REMOVE BARK MULCH IN THE RIGHT SIDE DRAINAGE CONVEYANCE AND PUT SOD WHERE IT IS WHITELINED. NOTING THAT THERE IS AN AREA IN BACK WHERE REAR PROPERY OWNERS FENCE IS LEANING ONTO THIS PROPERTY. APPEARS IF THE DEBIS IS REMOVED THE FENCE WILL COLLAPSE. | |||
| ROW- PRE-APRON (PRE-POUR) | 06/02/2023 | APPROVED - AS NOTED | FSLADISH |
| Note: 06/02/23 PIPE IS GOOD. LOOKED GOOD AT TIME OF INSPECTION. READY TO POUR. AT THE TIME OF THE INSPECTION CULVERT PIPE IS GOOD IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD DOUBLE CHECK CULVERT ELEVATIONS BEFORE POURING. MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL | |||
| ELECTRIC - EARLY POWER | 05/04/2023 | APPROVED - AS NOTED | KSANDOE |
| Note: Emailed FPL @ 0939. Release Power 5/2/2023 - PREVIOUS INSPECTION NOTES No change from previous notes 4/28/2023 - PREVIOUS INSPECTION NOTES 4/28/2023---Please have romex wires safed off using box with cover. (concealed). @ garage lights, under kitchen sink, Microwave. 4/24/2023 - PREVIOUS INSPECTION NOTES Notes from previous inspection have not been addressed Inspector Notes from Inspection 2200 Emailed FPL @ 8:45 AM 1. Breaker in meter main needs to be labeled NEC 210.5 2. Ground wire needs to be protected by ridgid PVC (liquid tight not approved in locations subjuct to physical damage) NEC 356.12 Have repaires made by early power | |||
| ELECTRIC - EARLY POWER | 05/02/2023 | Disapproved - NO FEE | KSANDOE |
| Note: No change from previous notes 4/28/2023 - PREVIOUS INSPECTION NOTES 4/28/2023---Please have romex wires safed off using box with cover. (concealed). @ garage lights, under kitchen sink, Microwave. 4/24/2023 - PREVIOUS INSPECTION NOTES Notes from previous inspection have not been addressed Inspector Notes from Inspection 2200 Emailed FPL @ 8:45 AM 1. Breaker in meter main needs to be labeled NEC 210.5 2. Ground wire needs to be protected by ridgid PVC (liquid tight not approved in locations subjuct to physical damage) NEC 356.12 Have repaires made by early power | |||
| ELECTRIC - EARLY POWER | 04/28/2023 | Disapproved - NO FEE | JSTEWART |
| Note: 4/28/2023---Please have romex wires safed off using box with cover. (concealed). @ garage lights, under kitchen sink, Microwave. 4/24/2023 - PREVIOUS INSPECTION NOTES Notes from previous inspection have not been addressed Inspector Notes from Inspection 2200 Emailed FPL @ 8:45 AM 1. Breaker in meter main needs to be labeled NEC 210.5 2. Ground wire needs to be protected by ridgid PVC (liquid tight not approved in locations subjuct to physical damage) NEC 356.12 Have repaires made by early power | |||
| GRAVITY SEWER TEST | 04/25/2023 | APPROVED | KSANDOE |
| U - SEWER TIE IN | 04/25/2023 | APPROVED | KSANDOE |
| ELECTRIC - EARLY POWER | 04/24/2023 | Disapproved -FEE REQUIRED | KSANDOE |
| Note: Notes from previous inspection have not been addressed Inspector Notes from Inspection 2200 Emailed FPL @ 8:45 AM 1. Breaker in meter main needs to be labeled NEC 210.5 2. Ground wire needs to be protected by ridgid PVC (liquid tight not approved in locations subjuct to physical damage) NEC 356.12 Have repaires made by early power | |||
| INSULATION | 03/22/2023 | APPROVED | KSANDOE |
| ALL ROUGH | 03/20/2023 | APPROVED | JSTEWART |
| Note: 3/17/2023 - PREVIOUS INSPECTION NOTES 3/17/23 No repairs have been made as noted in previous inspection 3/16/2023 - PREVIOUS INSPECTION NOTES House has been insulated before passing All Rough Inspection. Remove insulation to expose nail plates for inspection. DO NOT continue work before passing inspection at any stage 3/15/2023 - PREVIOUS INSPECTION NOTES 3/14/2023 - PREVIOUS INSPECTION NOTES No change from previous inspection. Walk your job before scheduling inspections 3/13/2023 - PREVIOUS INSPECTION NOTES Missing protection for plumbing in owners shower, top plate, garage separation wall 5ft head test failed Water pressure test failed Tub set not holding water Close up slab for tub set AC lineset not installed | |||
| ALL ROUGH | 03/17/2023 | Disapproved -FEE REQUIRED | MKRASKI |
| Note: 3/17/23 No repairs have been made as noted in previous inspection 3/16/2023 - PREVIOUS INSPECTION NOTES House has been insulated before passing All Rough Inspection. Remove insulation to expose nail plates for inspection. DO NOT continue work before passing inspection at any stage 3/15/2023 - PREVIOUS INSPECTION NOTES 3/14/2023 - PREVIOUS INSPECTION NOTES No change from previous inspection. Walk your job before scheduling inspections 3/13/2023 - PREVIOUS INSPECTION NOTES Missing protection for plumbing in owners shower, top plate, garage separation wall 5ft head test failed Water pressure test failed Tub set not holding water Close up slab for tub set AC lineset not installed | |||
| ALL ROUGH | 03/16/2023 | Disapproved -FEE REQUIRED | KSANDOE |
| Note: House has been insulated before passing All Rough Inspection. Remove insulation to expose nail plates for inspection. DO NOT continue work before passing inspection at any stage 3/15/2023 - PREVIOUS INSPECTION NOTES 3/14/2023 - PREVIOUS INSPECTION NOTES No change from previous inspection. Walk your job before scheduling inspections 3/13/2023 - PREVIOUS INSPECTION NOTES Missing protection for plumbing in owners shower, top plate, garage separation wall 5ft head test failed Water pressure test failed Tub set not holding water Close up slab for tub set AC lineset not installed | |||
| ALL ROUGH | 03/15/2023 | CANCELLED BY APPLICANT | KSANDOE |
| Note: 3/14/2023 - PREVIOUS INSPECTION NOTES No change from previous inspection. Walk your job before scheduling inspections 3/13/2023 - PREVIOUS INSPECTION NOTES Missing protection for plumbing in owners shower, top plate, garage separation wall 5ft head test failed Water pressure test failed Tub set not holding water Close up slab for tub set AC lineset not installed | |||
| ALL ROUGH | 03/14/2023 | Disapproved -FEE REQUIRED | KSANDOE |
| Note: No change from previous inspection. Walk your job before scheduling inspections 3/13/2023 - PREVIOUS INSPECTION NOTES Missing protection for plumbing in owners shower, top plate, garage separation wall 5ft head test failed Water pressure test failed Tub set not holding water Close up slab for tub set AC lineset not installed | |||
| ALL ROUGH | 03/13/2023 | Disapproved - NO FEE | KSANDOE |
| Note: Missing protection for plumbing in owners shower, top plate, garage separation wall 5ft head test failed Water pressure test failed Tub set not holding water Close up slab for tub set AC lineset not installed | |||
| ELECTRIC-TUG | 03/07/2023 | APPROVED - AS NOTED | MKRASKI |
| Note: Emailed FPL @ 8:45 AM 1. Breaker in meter main needs to be labeled NEC 210.5 2. Ground wire needs to be protected by ridgid PVC (liquid tight not approved in locations subjuct to physical damage) NEC 356.12 Have repaires made by early power | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 02/24/2023 | APPROVED | KSANDOE |
| Note: 2/17/2023 - PREVIOUS INSPECTION NOTES 2/17/2023- No header detail for bearing wall on plans provided. no bearing wall to CMU detail in plans provided No 1/2' wedge anchor W/2' washer bottom plate of bearing wall per plan PG A-4 2/10/2023 - PREVIOUS INSPECTION NOTES No header detail for bearing wall detail on plans provided No bearing wall to CMU detail in plans provided Missing blocking on bearing walls per plans The rest is approved | |||
| ROOF VALLEY & METAL | 02/23/2023 | APPROVED | KSANDOE |
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 02/17/2023 | Disapproved - NO FEE | JSTEWART |
| Note: 2/17/2023- No header detail for bearing wall on plans provided. no bearing wall to CMU detail in plans provided No 1/2' wedge anchor W/2' washer bottom plate of bearing wall per plan PG A-4 2/10/2023 - PREVIOUS INSPECTION NOTES No header detail for bearing wall detail on plans provided No bearing wall to CMU detail in plans provided Missing blocking on bearing walls per plans The rest is approved | |||
| LATH/BRICK/ WATER BARRIER | 02/14/2023 | APPROVED | KSANDOE |
| WALL SHEATHING | 02/10/2023 | APPROVED | TSTAUFFACHER |
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 02/10/2023 | Disapproved - NO FEE | TSTAUFFACHER |
| Note: No header detail for bearing wall detail on plans provided No bearing wall to CMU detail in plans provided Missing blocking on bearing walls per plans The rest is approved | |||
| FOUND SURVEY APPROVED (OFFICE) | 02/06/2023 | APPROVED | JHOWARD |
| TIE BEAM / LINTEL | 01/27/2023 | APPROVED | KSANDOE |
| MONOLITHIC SLAB | 01/19/2023 | APPROVED | KSANDOE |
| PLUMBING 1ST ROUGH UNDERGROUND | 01/17/2023 | APPROVED | MGIBSON |
| WATER METER INSTALLATION REQUEST | 01/11/2023 | APPROVED | CSTONE |
| Note: 12/22/2022 8:43:05 AM- PREVIOUS INSPECTION NOTES not clear debris on lot line | |||
| WATER METER INSTALLATION REQUEST | 12/21/2022 | Disapproved - NO FEE | CSTONE |
| Note: not clear debris on lot line |
Review History
| Department | Status | Date In | Date Out |
| MECH | COMPLETE | 06/07/2023 | 06/07/2023 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| MECH | HOLD | 06/02/2023 | 06/02/2023 |
| Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Energy Calcs need to be signed by the owner/ owner agent below the preparer per R103.1.1.2 FBC Energy Conservation 2020 7Th edition | |||
| BLD | COMPLETE | 03/08/2023 | 03/09/2023 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 02/24/2023 | 02/27/2023 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 02/06/2023 | 02/06/2023 |
| Note: Released By: JOHN HOWARD - - JHOWARD@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 02/06/2023 | 02/06/2023 |
| Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 09/08/2022 | 09/08/2022 |
| Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM | |||
| CUSVC | COMPLETE | 09/08/2022 | 09/08/2022 |
| Note: Released By: LISA ASBILL - - lasbill@palmcoastgov.com | |||
| ENGIN1 | COMPLETE | 09/08/2022 | 09/08/2022 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| SW1 | COMPLETE | 09/08/2022 | 09/15/2022 |
| Note: Released By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 08/22/2022 | 08/24/2022 |
| Note: Released By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM | |||
| CUSVC | COMPLETE | 08/22/2022 | 08/24/2022 |
| Note: Released By: HALEIGH HAND - - | |||
| ELEC | COMPLETE | 08/22/2022 | 08/22/2022 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 08/22/2022 | 08/22/2022 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| LOCATE | COMPLETE | 08/22/2022 | 08/26/2022 |
| Note: Released By: CANDACE STONE - - CSTONE@PALMCOASTGOV.COM | |||
| MECH | COMPLETE | 08/22/2022 | 08/22/2022 |
| Note: Released By: CHRIS PISCITELLI - (386)986-3782 - CPISCITELLI@PALMCOASTGOV.COM | |||
| SW1 | COMPLETE | 08/22/2022 | 08/29/2022 |
| Note: Released By: ROBERT GROSS - (386)986-4769 - RGROSS@PALMCOASTGOV.COM | |||
| ZON | HOLD | 08/22/2022 | 08/24/2022 |
| Note: Held By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM This lot has two flood map numbers. Both should be listed on the site plan/survey | |||
| SWALE | COMPLETE | 08/22/2022 | 12/08/2022 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| PLAN REVIEW - REVISION | ¤32.50 | 08/15/2023 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 08/15/2023 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 08/15/2023 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 08/15/2023 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 08/15/2023 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 08/15/2023 |
| CONNECTION FEES | ¤1,077.88 | 10/13/2022 |
| 3% FIRE IMPACT FEE CREDIT | (¤11.66) | 10/13/2022 |
| IMPACT FEE FIRE | ¤388.65 | 10/13/2022 |
| IMPACT FEE PARKS | ¤1,455.13 | 10/13/2022 |
| IMPACT FEE SCHOOL | ¤3,600.00 | 10/13/2022 |
| IMPACT FEE TRANSPORTATION | ¤1,764.00 | 10/13/2022 |
| WATER -IRRIGATION INSPECTION | ¤25.00 | 10/13/2022 |
| 3% PARKS IMPACT FEE CREDIT | (¤43.65) | 10/13/2022 |
| SURCHARGE FS 533.721 | ¤2.47 | 10/13/2022 |
| SURCHARGE - FS 468.631 | ¤3.71 | 10/13/2022 |
| SW ENG - FOUNDATION SURVEY | ¤20.00 | 10/13/2022 |
| SW ENG INSPECTION 80 | ¤80.00 | 10/13/2022 |
| SW ENG PRE APRON | ¤30.00 | 10/13/2022 |
| SW ENG - REVIEW 20 | ¤20.00 | 10/13/2022 |
| SW ENG RES REVIEW 200 | ¤200.00 | 10/13/2022 |
| 3% TRANS IMPACT FEE CREDIT | (¤52.92) | 10/13/2022 |
| SEWER CREDIT | (¤957.72) | 10/13/2022 |
| SEWER INSPECTION | ¤25.00 | 10/13/2022 |
| SEWER CAPITAL FACILITY | ¤4,939.76 | 10/13/2022 |
| WATER CREDIT | (¤592.00) | 10/13/2022 |
| WATER CAPITAL FACILITY FEE | ¤3,626.50 | 10/13/2022 |
| SITE PLAN 30 | ¤30.00 | 10/13/2022 |
| WATER- TURN ON | ¤25.00 | 10/13/2022 |
| ADJUSTMENT 50% | (¤366.24) | 10/13/2022 |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | 10/13/2022 |
| INSPECTION - RESIDENTIAL | ¤547.25 | 10/13/2022 |
| PLAN REVIEW - RESIDENTIAL | ¤155.22 | 10/13/2022 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤16,253.88 |