I want to search for...

Permit #2022081153

Permit Details

Status: COED

Parcel Id: 07-11-31-7025-00650-0140
CONDITIONED SPACE: 1555 sqft
GARAGE: 434 sqft
OPENED PORCH (WITH ROOF) : 112 sqft
OPENED PORCH (WITH ROOF) : 100 sqft
Total Square Footage: 2201 sqft
Block: 00650
Subdivision: 2189 - SECTION 25-PINE GROVE
Job Phone: 832-726-2202
Location Address: 43 PATUXENT LN
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 10/13/2022
NOC: RECORDED
Applicant name: JONATHON AMBAR
Owner: CASPIAN PERFORMANCE GROUP LLC

Address

1802 N ALFAYA TRL, STE 162

ORLANDO, FL 32826

Lot: 0140
Contracted Stated Job Value: ¤131,500.00
Job Description: SINGLE FAMILY RESIDENCE
Type: CN

Contractor

CASPIAN HOMES, LLC
Status Location Address Mailing Address State License Number Phone
ACTIVE

1802 N ALAFAYA TRAIL

ORLANDO, FL 32826

SUITE 162

ORLANDO, FL 32826

CBC1264918 (Exp: 08/31/2026) 832-726-2202

Sub Contractors

TERRY BRICE DICKERSON
Status Location Address State License Number Phone
ACTIVE

4300 ST JOHN'S PARKWAY

ALPHARETTA, GA 30009

CCC1326209 (Exp: 08/31/2026) 407-548-6733
JONATHAN M PEARSON
Status Location Address State License Number Phone Fax
ACTIVE

209 N FORSYTH ST

BUNNELL, FL 32110

CFC1425941 (Exp: 08/31/2026) 386-597-0944 386-437-4996
DAVID SCOTT MORRIS
Status Location Address State License Number Phone
INACTIVE

63 LEIDEL DR

PALM COAST, FL 32137

ER13015750 (Exp: 08/31/2026) 386-569-7262
ROBERT MICHAEL RENNER
Status Location Address State License Number Phone
ACTIVE

531 CODISCO WAY

SANFORD, FL 32771

CAC051477 (Exp: 08/31/2026) 407-333-2665

Inspection History

Type Request Date Result Inspector
BLD - BUILDING FINAL 07/28/2023 FINAL APPROVED KSANDOE
Note: New inspection due to canceled inspection 7/19/2023 - PREVIOUS INSPECTION NOTES 7/18/7/19/23 1. No insualtion report, or blower door test report 2. T-stat wire needs to be sealed @ ceiling in AHU closet 3. Energy cals do not match 4. No attic access door 5. Slab is damaged behind water heater exposing water lines, slab needs to be repaired 6. AHU has wrong size breaker installed on unit and in panel 2023 - PREVIOUS INSPECTION NOTES 1. Large hole where Cat5 comes through wall @ meter mail needs to be sealed 2. Meter main breaker is not labeled 3. Large holes in stucco by ODU Stopped inspection outside
BLD - BUILDING FINAL 07/24/2023 CANCELLED BY APPLICANT WEB
Note: 7/19/2023 - PREVIOUS INSPECTION NOTES 7/18/7/19/23 1. No insualtion report, or blower door test report 2. T-stat wire needs to be sealed @ ceiling in AHU closet 3. Energy cals do not match 4. No attic access door 5. Slab is damaged behind water heater exposing water lines, slab needs to be repaired 6. AHU has wrong size breaker installed on unit and in panel 2023 - PREVIOUS INSPECTION NOTES 1. Large hole where Cat5 comes through wall @ meter mail needs to be sealed 2. Meter main breaker is not labeled 3. Large holes in stucco by ODU Stopped inspection outside
BLD - BUILDING FINAL 07/19/2023 Disapproved -FEE REQUIRED MKRASKI
Note: 7/18/7/19/23 1. No insualtion report, or blower door test report 2. T-stat wire needs to be sealed @ ceiling in AHU closet 3. Energy cals do not match 4. No attic access door 5. Slab is damaged behind water heater exposing water lines, slab needs to be repaired 6. AHU has wrong size breaker installed on unit and in panel 2023 - PREVIOUS INSPECTION NOTES 1. Large hole where Cat5 comes through wall @ meter mail needs to be sealed 2. Meter main breaker is not labeled 3. Large holes in stucco by ODU Stopped inspection outside
BLD - BUILDING FINAL 07/18/2023 Disapproved - NO FEE MKRASKI
Note: 1. Large hole where Cat5 comes through wall @ meter mail needs to be sealed 2. Meter main breaker is not labeled 3. Large holes in stucco by ODU Stopped inspection outside
U-CROSS CONNECTION 07/18/2023 APPROVED - AS NOTED LFITZGERALD
Note: no irrigation-no cross connection
ROW - FINAL APRON (AFTER POUR) 07/18/2023 APPROVED FSLADISH
Note: 7/18/23 PIPE IS GOOD. CUTS MADE. CULVERT CLEAR. LOOKED GOOD AT THE TIME OF THIS INSPECTION ____________________________________________________________________________________________________________________________ 7/12/2023 - PREVIOUS INSPECTION NOTES
ROW - STORMWATER FINAL 07/18/2023 FINAL APPROVED FSLADISH
Note: 07/18/23 SEE PREVIOUS NOTES WITH REGARD TO LEANING FENCE AND DEBRIS. CORRECTIONS MADE. LOOKED GOOD AT THE TIME OF THIS FINAL ROW INSPECTION. ________________________________________________________________________________________________________________________ 7/12/2023 - PREVIOUS INSPECTION NOTES 07/11/23 NEED TO REMOVE BARK MULCH IN THE RIGHT SIDE DRAINAGE CONVEYANCE AND PUT SOD WHERE IT IS WHITELINED. NOTING THAT THERE IS AN AREA IN BACK WHERE REAR PROPERY OWNERS FENCE IS LEANING ONTO THIS PROPERTY. APPEARS IF THE DEBIS IS REMOVED THE FENCE WILL COLLAPSE
U -UTILITY RESIDENTIAL FINAL 07/12/2023 FINAL APPROVED LFITZGERALD
ROW - STORMWATER FINAL 07/12/2023 CANCELLED BY APPLICANT FSLADISH
Note: 07/11/23 NEED TO REMOVE BARK MULCH IN THE RIGHT SIDE DRAINAGE CONVEYANCE AND PUT SOD WHERE IT IS WHITELINED. NOTING THAT THERE IS AN AREA IN BACK WHERE REAR PROPERY OWNERS FENCE IS LEANING ONTO THIS PROPERTY. APPEARS IF THE DEBIS IS REMOVED THE FENCE WILL COLLAPSE
ROW - FINAL APRON (AFTER POUR) 07/12/2023 CANCELLED BY APPLICANT FSLADISH
ROW- FINAL SURVEY/GRADING CERTIFICATION 07/11/2023 APPROVED FSLADISH
Note: Inspector Notes from Inspection 9270 06/02/23 PIPE IS GOOD. LOOKED GOOD AT TIME OF INSPECTION. READY TO POUR. AT THE TIME OF THE INSPECTION CULVERT PIPE IS GOOD IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD DOUBLE CHECK CULVERT ELEVATIONS BEFORE POURING. MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL
ROW FIELD SURVEY /GRADING CERTIFICATION 07/11/2023 APPROVED FSLADISH
Note: 07/11/23 NEED TO REMOVE BARK MULCH IN THE RIGHT SIDE DRAINAGE CONVEYANCE AND PUT SOD WHERE IT IS WHITELINED. NOTING THAT THERE IS AN AREA IN BACK WHERE REAR PROPERY OWNERS FENCE IS LEANING ONTO THIS PROPERTY. APPEARS IF THE DEBIS IS REMOVED THE FENCE WILL COLLAPSE.
ROW- PRE-APRON (PRE-POUR) 06/02/2023 APPROVED - AS NOTED FSLADISH
Note: 06/02/23 PIPE IS GOOD. LOOKED GOOD AT TIME OF INSPECTION. READY TO POUR. AT THE TIME OF THE INSPECTION CULVERT PIPE IS GOOD IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD DOUBLE CHECK CULVERT ELEVATIONS BEFORE POURING. MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL
ELECTRIC - EARLY POWER 05/04/2023 APPROVED - AS NOTED KSANDOE
Note: Emailed FPL @ 0939. Release Power 5/2/2023 - PREVIOUS INSPECTION NOTES No change from previous notes 4/28/2023 - PREVIOUS INSPECTION NOTES 4/28/2023---Please have romex wires safed off using box with cover. (concealed). @ garage lights, under kitchen sink, Microwave. 4/24/2023 - PREVIOUS INSPECTION NOTES Notes from previous inspection have not been addressed Inspector Notes from Inspection 2200 Emailed FPL @ 8:45 AM 1. Breaker in meter main needs to be labeled NEC 210.5 2. Ground wire needs to be protected by ridgid PVC (liquid tight not approved in locations subjuct to physical damage) NEC 356.12 Have repaires made by early power
ELECTRIC - EARLY POWER 05/02/2023 Disapproved - NO FEE KSANDOE
Note: No change from previous notes 4/28/2023 - PREVIOUS INSPECTION NOTES 4/28/2023---Please have romex wires safed off using box with cover. (concealed). @ garage lights, under kitchen sink, Microwave. 4/24/2023 - PREVIOUS INSPECTION NOTES Notes from previous inspection have not been addressed Inspector Notes from Inspection 2200 Emailed FPL @ 8:45 AM 1. Breaker in meter main needs to be labeled NEC 210.5 2. Ground wire needs to be protected by ridgid PVC (liquid tight not approved in locations subjuct to physical damage) NEC 356.12 Have repaires made by early power
ELECTRIC - EARLY POWER 04/28/2023 Disapproved - NO FEE JSTEWART
Note: 4/28/2023---Please have romex wires safed off using box with cover. (concealed). @ garage lights, under kitchen sink, Microwave. 4/24/2023 - PREVIOUS INSPECTION NOTES Notes from previous inspection have not been addressed Inspector Notes from Inspection 2200 Emailed FPL @ 8:45 AM 1. Breaker in meter main needs to be labeled NEC 210.5 2. Ground wire needs to be protected by ridgid PVC (liquid tight not approved in locations subjuct to physical damage) NEC 356.12 Have repaires made by early power
GRAVITY SEWER TEST 04/25/2023 APPROVED KSANDOE
U - SEWER TIE IN 04/25/2023 APPROVED KSANDOE
ELECTRIC - EARLY POWER 04/24/2023 Disapproved -FEE REQUIRED KSANDOE
Note: Notes from previous inspection have not been addressed Inspector Notes from Inspection 2200 Emailed FPL @ 8:45 AM 1. Breaker in meter main needs to be labeled NEC 210.5 2. Ground wire needs to be protected by ridgid PVC (liquid tight not approved in locations subjuct to physical damage) NEC 356.12 Have repaires made by early power
INSULATION 03/22/2023 APPROVED KSANDOE
ALL ROUGH 03/20/2023 APPROVED JSTEWART
Note: 3/17/2023 - PREVIOUS INSPECTION NOTES 3/17/23 No repairs have been made as noted in previous inspection 3/16/2023 - PREVIOUS INSPECTION NOTES House has been insulated before passing All Rough Inspection. Remove insulation to expose nail plates for inspection. DO NOT continue work before passing inspection at any stage 3/15/2023 - PREVIOUS INSPECTION NOTES 3/14/2023 - PREVIOUS INSPECTION NOTES No change from previous inspection. Walk your job before scheduling inspections 3/13/2023 - PREVIOUS INSPECTION NOTES Missing protection for plumbing in owners shower, top plate, garage separation wall 5ft head test failed Water pressure test failed Tub set not holding water Close up slab for tub set AC lineset not installed
ALL ROUGH 03/17/2023 Disapproved -FEE REQUIRED MKRASKI
Note: 3/17/23 No repairs have been made as noted in previous inspection 3/16/2023 - PREVIOUS INSPECTION NOTES House has been insulated before passing All Rough Inspection. Remove insulation to expose nail plates for inspection. DO NOT continue work before passing inspection at any stage 3/15/2023 - PREVIOUS INSPECTION NOTES 3/14/2023 - PREVIOUS INSPECTION NOTES No change from previous inspection. Walk your job before scheduling inspections 3/13/2023 - PREVIOUS INSPECTION NOTES Missing protection for plumbing in owners shower, top plate, garage separation wall 5ft head test failed Water pressure test failed Tub set not holding water Close up slab for tub set AC lineset not installed
ALL ROUGH 03/16/2023 Disapproved -FEE REQUIRED KSANDOE
Note: House has been insulated before passing All Rough Inspection. Remove insulation to expose nail plates for inspection. DO NOT continue work before passing inspection at any stage 3/15/2023 - PREVIOUS INSPECTION NOTES 3/14/2023 - PREVIOUS INSPECTION NOTES No change from previous inspection. Walk your job before scheduling inspections 3/13/2023 - PREVIOUS INSPECTION NOTES Missing protection for plumbing in owners shower, top plate, garage separation wall 5ft head test failed Water pressure test failed Tub set not holding water Close up slab for tub set AC lineset not installed
ALL ROUGH 03/15/2023 CANCELLED BY APPLICANT KSANDOE
Note: 3/14/2023 - PREVIOUS INSPECTION NOTES No change from previous inspection. Walk your job before scheduling inspections 3/13/2023 - PREVIOUS INSPECTION NOTES Missing protection for plumbing in owners shower, top plate, garage separation wall 5ft head test failed Water pressure test failed Tub set not holding water Close up slab for tub set AC lineset not installed
ALL ROUGH 03/14/2023 Disapproved -FEE REQUIRED KSANDOE
Note: No change from previous inspection. Walk your job before scheduling inspections 3/13/2023 - PREVIOUS INSPECTION NOTES Missing protection for plumbing in owners shower, top plate, garage separation wall 5ft head test failed Water pressure test failed Tub set not holding water Close up slab for tub set AC lineset not installed
ALL ROUGH 03/13/2023 Disapproved - NO FEE KSANDOE
Note: Missing protection for plumbing in owners shower, top plate, garage separation wall 5ft head test failed Water pressure test failed Tub set not holding water Close up slab for tub set AC lineset not installed
ELECTRIC-TUG 03/07/2023 APPROVED - AS NOTED MKRASKI
Note: Emailed FPL @ 8:45 AM 1. Breaker in meter main needs to be labeled NEC 210.5 2. Ground wire needs to be protected by ridgid PVC (liquid tight not approved in locations subjuct to physical damage) NEC 356.12 Have repaires made by early power
ROOF SHEATHING / BRACES/TIES/DOWN CELL 02/24/2023 APPROVED KSANDOE
Note: 2/17/2023 - PREVIOUS INSPECTION NOTES 2/17/2023- No header detail for bearing wall on plans provided. no bearing wall to CMU detail in plans provided No 1/2' wedge anchor W/2' washer bottom plate of bearing wall per plan PG A-4 2/10/2023 - PREVIOUS INSPECTION NOTES No header detail for bearing wall detail on plans provided No bearing wall to CMU detail in plans provided Missing blocking on bearing walls per plans The rest is approved
ROOF VALLEY & METAL 02/23/2023 APPROVED KSANDOE
ROOF SHEATHING / BRACES/TIES/DOWN CELL 02/17/2023 Disapproved - NO FEE JSTEWART
Note: 2/17/2023- No header detail for bearing wall on plans provided. no bearing wall to CMU detail in plans provided No 1/2' wedge anchor W/2' washer bottom plate of bearing wall per plan PG A-4 2/10/2023 - PREVIOUS INSPECTION NOTES No header detail for bearing wall detail on plans provided No bearing wall to CMU detail in plans provided Missing blocking on bearing walls per plans The rest is approved
LATH/BRICK/ WATER BARRIER 02/14/2023 APPROVED KSANDOE
WALL SHEATHING 02/10/2023 APPROVED TSTAUFFACHER
ROOF SHEATHING / BRACES/TIES/DOWN CELL 02/10/2023 Disapproved - NO FEE TSTAUFFACHER
Note: No header detail for bearing wall detail on plans provided No bearing wall to CMU detail in plans provided Missing blocking on bearing walls per plans The rest is approved
FOUND SURVEY APPROVED (OFFICE) 02/06/2023 APPROVED JHOWARD
TIE BEAM / LINTEL 01/27/2023 APPROVED KSANDOE
MONOLITHIC SLAB 01/19/2023 APPROVED KSANDOE
PLUMBING 1ST ROUGH UNDERGROUND 01/17/2023 APPROVED MGIBSON
WATER METER INSTALLATION REQUEST 01/11/2023 APPROVED CSTONE
Note: 12/22/2022 8:43:05 AM- PREVIOUS INSPECTION NOTES not clear debris on lot line
WATER METER INSTALLATION REQUEST 12/21/2022 Disapproved - NO FEE CSTONE
Note: not clear debris on lot line

Review History

Department Status Date In Date Out
MECH COMPLETE 06/07/2023 06/07/2023
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
MECH HOLD 06/02/2023 06/02/2023
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Energy Calcs need to be signed by the owner/ owner agent below the preparer per R103.1.1.2 FBC Energy Conservation 2020 7Th edition
BLD COMPLETE 03/08/2023 03/09/2023
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
BLD COMPLETE 02/24/2023 02/27/2023
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
ENGIN1 COMPLETE 02/06/2023 02/06/2023
Note: Released By: JOHN HOWARD - - JHOWARD@PALMCOASTGOV.COM
ZON COMPLETE 02/06/2023 02/06/2023
Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM
ZON COMPLETE 09/08/2022 09/08/2022
Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM
CUSVC COMPLETE 09/08/2022 09/08/2022
Note: Released By: LISA ASBILL - - lasbill@palmcoastgov.com
ENGIN1 COMPLETE 09/08/2022 09/08/2022
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
SW1 COMPLETE 09/08/2022 09/15/2022
Note: Released By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM
BLD COMPLETE 08/22/2022 08/24/2022
Note: Released By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM
CUSVC COMPLETE 08/22/2022 08/24/2022
Note: Released By: HALEIGH HAND - -
ELEC COMPLETE 08/22/2022 08/22/2022
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
ENGIN1 COMPLETE 08/22/2022 08/22/2022
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
LOCATE COMPLETE 08/22/2022 08/26/2022
Note: Released By: CANDACE STONE - - CSTONE@PALMCOASTGOV.COM
MECH COMPLETE 08/22/2022 08/22/2022
Note: Released By: CHRIS PISCITELLI - (386)986-3782 - CPISCITELLI@PALMCOASTGOV.COM
SW1 COMPLETE 08/22/2022 08/29/2022
Note: Released By: ROBERT GROSS - (386)986-4769 - RGROSS@PALMCOASTGOV.COM
ZON HOLD 08/22/2022 08/24/2022
Note: Held By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM This lot has two flood map numbers. Both should be listed on the site plan/survey
SWALE COMPLETE 08/22/2022 12/08/2022
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
PLAN REVIEW - REVISION ¤32.50 08/15/2023
REINSPECTION RESIDENTIAL ¤40.00 08/15/2023
REINSPECTION RESIDENTIAL ¤40.00 08/15/2023
REINSPECTION RESIDENTIAL ¤40.00 08/15/2023
REINSPECTION RESIDENTIAL ¤40.00 08/15/2023
REINSPECTION RESIDENTIAL ¤40.00 08/15/2023
CONNECTION FEES ¤1,077.88 10/13/2022
3% FIRE IMPACT FEE CREDIT (¤11.66) 10/13/2022
IMPACT FEE FIRE ¤388.65 10/13/2022
IMPACT FEE PARKS ¤1,455.13 10/13/2022
IMPACT FEE SCHOOL ¤3,600.00 10/13/2022
IMPACT FEE TRANSPORTATION ¤1,764.00 10/13/2022
WATER -IRRIGATION INSPECTION ¤25.00 10/13/2022
3% PARKS IMPACT FEE CREDIT (¤43.65) 10/13/2022
SURCHARGE FS 533.721 ¤2.47 10/13/2022
SURCHARGE - FS 468.631 ¤3.71 10/13/2022
SW ENG - FOUNDATION SURVEY ¤20.00 10/13/2022
SW ENG INSPECTION 80 ¤80.00 10/13/2022
SW ENG PRE APRON ¤30.00 10/13/2022
SW ENG - REVIEW 20 ¤20.00 10/13/2022
SW ENG RES REVIEW 200 ¤200.00 10/13/2022
3% TRANS IMPACT FEE CREDIT (¤52.92) 10/13/2022
SEWER CREDIT (¤957.72) 10/13/2022
SEWER INSPECTION ¤25.00 10/13/2022
SEWER CAPITAL FACILITY ¤4,939.76 10/13/2022
WATER CREDIT (¤592.00) 10/13/2022
WATER CAPITAL FACILITY FEE ¤3,626.50 10/13/2022
SITE PLAN 30 ¤30.00 10/13/2022
WATER- TURN ON ¤25.00 10/13/2022
ADJUSTMENT 50% (¤366.24) 10/13/2022
ADMINISTRATIVE RESIDENTIAL ¤30.00 10/13/2022
INSPECTION - RESIDENTIAL ¤547.25 10/13/2022
PLAN REVIEW - RESIDENTIAL ¤155.22 10/13/2022
Fees Total Due: ¤0.00 Total Paid: ¤16,253.88