Permit #2022090042

Permit Details

Status: COED

Parcel Id: 07-11-31-7064-00090-0190
CONDITIONED SPACE: 1721 sqft
GARAGE: 455 sqft
OPENED PORCH (WITH ROOF) : 173 sqft
OPENED PORCH (WITH ROOF) : 110 sqft
Total Square Footage: 2459 sqft
Block: 00090
Subdivision: 2178 - SECTION 64-LAGUNA FOREST
Job Phone: 631-929-5500
Location Address: 18 LLACH CT
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 11/07/2022
NOC: RECORDED
Applicant name: NICHOLAS JOHN ZOUMAS
Owner: WICK PALM DEVELOPMENT LLC

Address

SUITE 110

GREENWOOD VILLAGE, CO 80111

Address

5460 S QUEBEC ST

GREENWOOD VILLAGE, CO 80111

Lot: 0190
Contracted Stated Job Value: ¤160,000.00
Job Description: Single Family Home
Type: CN

Contractor

JNS CONTRACTING FLORIDA, LLC
Status Location Address State License Number Phone
ACTIVE

256 ROUTE 25A

WADING RIVER, NY 11792

CGC1527793 (Exp: 08/31/2026) 631-929-5500

Sub Contractors

NICHOLAS JOHN ZOUMAS
Status Location Address State License Number Phone
ACTIVE

256 ROUTE 25A

WADING RIVER, NY 11792

CGC1527793 (Exp: 08/31/2026) 631-929-5500
JUAN CARLOS GONZALEZ
Status Location Address State License Number
ACTIVE

1328 COUNTY ROAD 308

CRESCENT CITY, FL 32112

RF11067806 (Exp: 08/31/2027)
JAMES MCGOVERN
Status Location Address Phone Fax
ACTIVE

PO BOX 354295

PALM COAST, FL 32137

(386)931-8940 (386)986-4835
JOSEPH HORATIO STRADA JR
Status Location Address State License Number Phone
ACTIVE

3400 ST JOHNS PARKWAY

SANFORD, FL 32771

EC13003715 (Exp: 08/31/2026) 877-906-1113
MICHAEL FRANK MORELLO
Status Location Address State License Number Phone Fax
ACTIVE

2 HARGROVE GRADE

PALM COAST, FL 32164

CAC1819466 (Exp: 08/31/2026) 386-445-5023 386-446-4614

Inspection History

Type Request Date Result Inspector
BLD - BUILDING FINAL 06/02/2023 FINAL APPROVED RMARTIN
Note: 4/28/2023 - PREVIOUS INSPECTION NOTES 4/28/23: Upon re-inspection noted two additional items. 1). AC condenser pad is (now) cracked all the way through and will need to be replaced. 2). Front door is missing door peephole/glass door viewer. **** Previously listed items 1 and 4 are not resolved properly. 1). Must be sealed with an approved fire resistent product. (which is why I asked for cement.) and 4). AHU return duct is still not properly sealed on the left side as required. 4/25/2023 - PREVIOUS INSPECTION NOTES 4/25/23: 1). Hole in CMU garage wall needs to be sealed with cement. 2). Master Bathroom toilet has no water. 3). AHU Breaker is too small. 4). AHU return duct is not sealed at the ceiling. 5). AC condensing unit has anchor that is not fully set (embedded) into pad. (front right side) 6). Missing Insulation certificate. 7). Garbage disposal has debris in it - jamming blades. 8). Water Heater relief valve drain tube is too long. Needs to be between 1-1/2" & 6" from the drain pan.(FBC-504.6) Also, need to seal the electric cable at the wall with firestop, mastic or joint compound. (no caulk). 9). 2" Service Feed pipe needs to be sealed at the soffit. (FBC-G2402.9) *** Permit box and debris left in garage needs to be removed.
ROW - STORMWATER FINAL 05/22/2023 APPROVED PFLANAGAN
Note: 4/28/2023 - PREVIOUS INSPECTION NOTES 4/28/23=NEED TO LOWER THE SWALE ON THE LEFT SIDE FROM HALF WAY DOWN TO THE END OF THE SWALE, YOU ARE STOPING THE FLOW . NEED TO SOD TE SWALE ON THE EMPTY LOT . +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 4/25/2023 - PREVIOUS INSPECTION NOTES 1) NEED TO HAVE ALL TRASH AND CONSTRUCTION DEBRIS PICK UP STILL 2) CULVERT PIPE NEED TO BE FREE FROM ANY DIRT ------------------------------------------------------------------------------------------- 4/12/2023 - PREVIOUS INSPECTION NOTES 1) NEED TO HAVE ALL TRASH AND CONSTRUCTION DEBRIS PICK UP IN THE VACANT LOT AND YOUR LOT 2) NEED TO HAVE ALL DIRT AND OVER POURED CONCRETE CLEANED OUT OF THE CULVERT 3) NEED TO HAVE ROAD DAMAGE DONE BEFORE THIS INSPECTION
ROW - STORMWATER FINAL 04/28/2023 Disapproved -FEE REQUIRED GBERTOLA
Note: 4/28/23=NEED TO LOWER THE SWALE ON THE LEFT SIDE FROM HALF WAY DOWN TO THE END OF THE SWALE, YOU ARE STOPING THE FLOW . NEED TO SOD TE SWALE ON THE EMPTY LOT . +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 4/25/2023 - PREVIOUS INSPECTION NOTES 1) NEED TO HAVE ALL TRASH AND CONSTRUCTION DEBRIS PICK UP STILL 2) CULVERT PIPE NEED TO BE FREE FROM ANY DIRT ------------------------------------------------------------------------------------------- 4/12/2023 - PREVIOUS INSPECTION NOTES 1) NEED TO HAVE ALL TRASH AND CONSTRUCTION DEBRIS PICK UP IN THE VACANT LOT AND YOUR LOT 2) NEED TO HAVE ALL DIRT AND OVER POURED CONCRETE CLEANED OUT OF THE CULVERT 3) NEED TO HAVE ROAD DAMAGE DONE BEFORE THIS INSPECTION
BLD - BUILDING FINAL 04/28/2023 Disapproved - NO FEE RSIMS
Note: 4/28/23: Upon re-inspection noted two additional items. 1). AC condenser pad is (now) cracked all the way through and will need to be replaced. 2). Front door is missing door peephole/glass door viewer. **** Previously listed items 1 and 4 are not resolved properly. 1). Must be sealed with an approved fire resistent product. (which is why I asked for cement.) and 4). AHU return duct is still not properly sealed on the left side as required. 4/25/2023 - PREVIOUS INSPECTION NOTES 4/25/23: 1). Hole in CMU garage wall needs to be sealed with cement. 2). Master Bathroom toilet has no water. 3). AHU Breaker is too small. 4). AHU return duct is not sealed at the ceiling. 5). AC condensing unit has anchor that is not fully set (embedded) into pad. (front right side) 6). Missing Insulation certificate. 7). Garbage disposal has debris in it - jamming blades. 8). Water Heater relief valve drain tube is too long. Needs to be between 1-1/2" & 6" from the drain pan.(FBC-504.6) Also, need to seal the electric cable at the wall with firestop, mastic or joint compound. (no caulk). 9). 2" Service Feed pipe needs to be sealed at the soffit. (FBC-G2402.9) *** Permit box and debris left in garage needs to be removed.
ROW - FINAL APRON (AFTER POUR) 04/25/2023 APPROVED PFLANAGAN
BLD - BUILDING FINAL 04/25/2023 Disapproved -FEE REQUIRED RSIMS
Note: 4/25/23: 1). Hole in CMU garage wall needs to be sealed with cement. 2). Master Bathroom toilet has no water. 3). AHU Breaker is too small. 4). AHU return duct is not sealed at the ceiling. 5). AC condensing unit has anchor that is not fully set (embedded) into pad. (front right side) 6). Missing Insulation certificate. 7). Garbage disposal has debris in it - jamming blades. 8). Water Heater relief valve drain tube is too long. Needs to be between 1-1/2" & 6" from the drain pan.(FBC-504.6) Also, need to seal the electric cable at the wall with firestop, mastic or joint compound. (no caulk). 9). 2" Service Feed pipe needs to be sealed at the soffit. (FBC-G2402.9) *** Permit box and debris left in garage needs to be removed.
U -UTILITY RESIDENTIAL FINAL 04/25/2023 FINAL APPROVED JHARDING
Note: 4/12/2023 - PREVIOUS INSPECTION NOTES No power. Need power to check pep system.
ROW - STORMWATER FINAL 04/25/2023 Disapproved -FEE REQUIRED PFLANAGAN
Note: 1) NEED TO HAVE ALL TRASH AND CONSTRUCTION DEBRIS PICK UP STILL 2) CULVERT PIPE NEED TO BE FREE FROM ANY DIRT ------------------------------------------------------------------------------------------- 4/12/2023 - PREVIOUS INSPECTION NOTES 1) NEED TO HAVE ALL TRASH AND CONSTRUCTION DEBRIS PICK UP IN THE VACANT LOT AND YOUR LOT 2) NEED TO HAVE ALL DIRT AND OVER POURED CONCRETE CLEANED OUT OF THE CULVERT 3) NEED TO HAVE ROAD DAMAGE DONE BEFORE THIS INSPECTION
ROW - STORMWATER FINAL 04/12/2023 Disapproved -FEE REQUIRED PFLANAGAN
Note: 1) NEED TO HAVE ALL TRASH AND CONSTRUCTION DEBRIS PICK UP IN THE VACANT LOT AND YOUR LOT 2) NEED TO HAVE ALL DIRT AND OVER POURED CONCRETE CLEANED OUT OF THE CULVERT 3) NEED TO HAVE ROAD DAMAGE DONE BEFORE THIS INSPECTION
U -UTILITY RESIDENTIAL FINAL 04/12/2023 Disapproved - NO FEE JHARDING
Note: No power. Need power to check pep system.
ROW- FINAL SURVEY/GRADING CERTIFICATION 04/11/2023 APPROVED PFLANAGAN
ROW FIELD SURVEY /GRADING CERTIFICATION 04/11/2023 APPROVED PFLANAGAN
U - SEWER TIE IN 03/23/2023 APPROVED MGIBSON
GRAVITY SEWER TEST 03/23/2023 APPROVED MGIBSON
ELECTRIC - EARLY POWER 03/07/2023 APPROVED RSIMS
Note: 3/6/2023 - PREVIOUS INSPECTION NOTES 3/6/23: 1). Service Feeds cannot be landed at Meter Panel for underground power before approved early power inspection. 2). Left side exterior - romex wire coming out of the wall is not safed off.
ELECTRIC - EARLY POWER 03/06/2023 Disapproved -FEE REQUIRED RSIMS
Note: 3/6/23: 1). Service Feeds cannot be landed at Meter Panel for underground power before approved early power inspection. 2). Left side exterior - romex wire coming out of the wall is not safed off.
ROW- PRE-APRON (PRE-POUR) 02/23/2023 APPROVED EMADISON
Note: ** 02/23/23 READY TO POUR IN THE EVENT OF RAIN RECHECK CULVERT ELEVATION AND COMPACTION ** MAKE SURE THERE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL
PEP TANK INSTALLATION REQUEST 01/30/2023 APPROVED TSCHWEERS
Note: 1/25/2023 9:15:03 AM- PREVIOUS INSPECTION NOTES 1/18/2023 8:23:05 AM- PREVIOUS INSPECTION NOTES dumpster will need to move 1/19/2023 Dumpster is still in the way for tank install.
PEP TANK INSTALLATION REQUEST 01/19/2023 Disapproved -FEE REQUIRED TSCHWEERS
Note: 1/18/2023 8:23:05 AM- PREVIOUS INSPECTION NOTES dumpster will need to move 1/19/2023 Dumpster is still in the way for tank install.
INSULATION 01/18/2023 APPROVED RSIMS
Note: 1/17/2023 - PREVIOUS INSPECTION NOTES 1/17/23: Still missing firestop at top plate penetration kitchen ceiling side as listed in item 1 previously. 1/13/2023 - PREVIOUS INSPECTION NOTES 1/13/23: 1). Missing firestop at top plate penetration for kitchen range hood vent line. 2). Laundry room - Missing firestop at top plate for 2" PVC vent line. 3). Bathroom - Missing firestop at top plate for 2" PVC vent line 4). Bathroom tub area - Missing firestop at top plate between bump out wall and bedroom wall.
INSULATION 01/17/2023 Disapproved -FEE REQUIRED RSIMS
Note: 1/17/23: Still missing firestop at top plate penetration kitchen ceiling side as listed in item 1 previously. 1/13/2023 - PREVIOUS INSPECTION NOTES 1/13/23: 1). Missing firestop at top plate penetration for kitchen range hood vent line. 2). Laundry room - Missing firestop at top plate for 2" PVC vent line. 3). Bathroom - Missing firestop at top plate for 2" PVC vent line 4). Bathroom tub area - Missing firestop at top plate between bump out wall and bedroom wall.
INSULATION 01/13/2023 Disapproved -FEE REQUIRED RSIMS
Note: 1/13/23: 1). Missing firestop at top plate penetration for kitchen range hood vent line. 2). Laundry room - Missing firestop at top plate for 2" PVC vent line. 3). Bathroom - Missing firestop at top plate for 2" PVC vent line 4). Bathroom tub area - Missing firestop at top plate between bump out wall and bedroom wall. Also, Persuant to the Contractor's News letter and Florida Building Codes 319.1 & 501.2 (& Emergency Services) - You must have the job box mounted out front. Address must be marked on the exterior of the home & be visible from the street with 4" tall minimum contrasting color lettering. (New construction - marking the windows with flourescent or reflective paint/other is acceptable).
U-CROSS CONNECTION 01/13/2023 APPROVED - AS NOTED LFITZGERALD
Note: no irrigatin-no cross connection
PEP TANK INSTALLATION REQUEST 01/13/2023 Disapproved - NO FEE CSTONE
Note: dumpster will need to move
LATH/BRICK/ WATER BARRIER 01/12/2023 APPROVED RSIMS
Note: 1/9/2023 - PREVIOUS INSPECTION NOTES 1/9/23 : Still missing lath / stop around back sliding door. 1/4/2023 - PREVIOUS INSPECTION NOTES 1/4/23: Lath is missing around back sliding door.
LATH/BRICK/ WATER BARRIER 01/09/2023 Disapproved -FEE REQUIRED RSIMS
Note: 1/9/23 : Still missing lath / stop around back sliding door. 1/4/2023 - PREVIOUS INSPECTION NOTES 1/4/23: Lath is missing around back sliding door.
ALL ROUGH 01/09/2023 APPROVED RSIMS
Note: 1/4/2023 - PREVIOUS INSPECTION NOTES 1/4/23: 1). 5ft head pressure is not holding. 2). Laundry room - missing nail plate at shoe plate for kitchen island wire. 3). Laundry room - water line needs to be secured inside of wall framing.
LATH/BRICK/ WATER BARRIER 01/04/2023 Disapproved - NO FEE RSIMS
Note: 1/4/23: Lath is missing around back sliding door.
ALL ROUGH 01/04/2023 Disapproved - NO FEE RSIMS
Note: 1/4/23: 1). 5ft head pressure is not holding. 2). Laundry room - missing nail plate at shoe plate for kitchen island wire. 3). Laundry room - water line needs to be secured inside of wall framing.
LATH/BRICK/ WATER BARRIER 12/29/2022 CANCELLED BY APPLICANT WEB
ROOF SHEATHING / BRACES/TIES/DOWN CELL 12/15/2022 APPROVED - AS NOTED AGAETANO
Note: Inspector Notes from Inspection 2450 12/14/22: Repair small hole in sheathing at top of left gable before brick/lathe inspection. 12-15-2022 Job site has trash around the exterior of the home. Please remove prior to next inspection.
ROOF VALLEY & METAL 12/15/2022 APPROVED AGAETANO
Note: Inspector Notes from Inspection 2450 12/14/22: Repair small hole in sheathing at top of left gable before brick/lathe inspection.
ROOF VALLEY & METAL 12/14/2022 Disapproved - NO FEE RSIMS
Note: 12/14/22: ROOF VALLEY METAL CANNOT BE APPROVED BEFORE ROOF SHEATHING.
WALL SHEATHING 12/14/2022 APPROVED - AS NOTED RSIMS
Note: 12/14/22: Repair small hole in sheathing at top of left gable before brick/lathe inspection.
ROOF SHEATHING / BRACES/TIES/DOWN CELL 12/14/2022 Disapproved -FEE REQUIRED RSIMS
Note: 12/14/22: NO PLANS IN BOX FOR INSPECTION! (except MiTech & truss layout) INSPECTION STOPPED! *** Truss engineering checked & approved. *** Roof sheathing bump checked - Disapproved (marked at areas below) 1). Loose sheathing at front wall. 2). Loose sheathing left side wall.
ELECTRIC-TUG 12/05/2022 APPROVED BTAYLOR
FOUND SURVEY APPROVED (OFFICE) 12/01/2022 APPROVED TBAKER
TIE BEAM / LINTEL 11/30/2022 APPROVED BTAYLOR
MONOLITHIC SLAB 11/15/2022 APPROVED BTAYLOR
Note: 11/14/2022 - PREVIOUS INSPECTION NOTES 11/14/2022: 1). No Compaction report or permit in permit box laying on the ground. 2). Clean out back left corner where hose bibb is to allow minimum 3" clearance to rebar. R404.1.3.3.7.4 Steel reinforcement in concrete cast against the earth shall have a minimum cover of 3 inches (75 mm).
MONOLITHIC SLAB 11/14/2022 Disapproved - NO FEE RSIMS
Note: 11/14/2022: 1). No Compaction report or permit in permit box laying on the ground. 2). Clean out back left corner where hose bibb is to allow minimum 3" clearance to rebar. R404.1.3.3.7.4 Steel reinforcement in concrete cast against the earth shall have a minimum cover of 3 inches (75 mm).
PLUMBING 1ST ROUGH UNDERGROUND 11/08/2022 APPROVED MGIBSON
WATER METER INSTALLATION REQUEST 11/08/2022 APPROVED CSTONE

Review History

Department Status Date In Date Out
MECH COMPLETE 02/14/2023 02/14/2023
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
ENGIN1 COMPLETE 11/30/2022 12/01/2022
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
ZON COMPLETE 11/30/2022 11/30/2022
Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM
BLD COMPLETE 09/01/2022 09/07/2022
Note: Released By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM
CUSVC COMPLETE 09/01/2022 09/06/2022
Note: Released By: LISA ASBILL - - lasbill@palmcoastgov.com
ELEC COMPLETE 09/01/2022 09/02/2022
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
ENGIN1 COMPLETE 09/01/2022 09/01/2022
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
LOCATE COMPLETE 09/01/2022 09/08/2022
Note: Released By: CANDACE STONE - - CSTONE@PALMCOASTGOV.COM
MECH COMPLETE 09/01/2022 09/02/2022
Note: Released By: CHRIS PISCITELLI - (386)986-3782 - CPISCITELLI@PALMCOASTGOV.COM
SW1 COMPLETE 09/01/2022 09/13/2022
Note: Released By: ROBERT GROSS - (386)986-4769 - RGROSS@PALMCOASTGOV.COM
ZON COMPLETE 09/01/2022 09/08/2022
Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM
SWALE COMPLETE 09/01/2022 12/21/2022
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
PLAN REVIEW - REVISION ¤32.50 06/02/2023
REINSPECTION RESIDENTIAL ¤40.00 06/02/2023
REINSPECTION RESIDENTIAL ¤40.00 06/02/2023
REINSPECTION RESIDENTIAL ¤40.00 06/02/2023
REINSPECTION RESIDENTIAL ¤40.00 06/02/2023
REINSPECTION RESIDENTIAL ¤40.00 06/02/2023
REINSPECTION RESIDENTIAL ¤40.00 06/02/2023
CONTRACTOR CHANGE ¤20.00 06/02/2023
SW ENG REINSPECTION 20 ¤20.00 06/02/2023
SW ENG REINSPECTION 20 ¤20.00 06/02/2023
SW ENG REINSPECTION 20 ¤20.00 06/02/2023
UTILITY PEP REINSPECTION ¤40.00 06/02/2023
SEWER CREDIT (¤2,291.75) 11/07/2022
SEWER INSPECTION ¤25.00 11/07/2022
SEWER CAPITAL FACILITY ¤4,939.76 11/07/2022
WATER CAPITAL FACILITY FEE ¤3,626.50 11/07/2022
SITE PLAN 30 ¤30.00 11/07/2022
SW ENG - REVIEW 20 ¤20.00 11/07/2022
SW ENG RES REVIEW 200 ¤200.00 11/07/2022
3% TRANS IMPACT FEE CREDIT (¤52.92) 11/07/2022
WATER- TURN ON ¤25.00 11/07/2022
ADJUSTMENT 50% (¤405.07) 11/07/2022
ADMINISTRATIVE RESIDENTIAL ¤30.00 11/07/2022
INSPECTION - RESIDENTIAL ¤607.75 11/07/2022
PLAN REVIEW - RESIDENTIAL ¤172.38 11/07/2022
3% FIRE IMPACT FEE CREDIT (¤11.66) 11/07/2022
IMPACT FEE FIRE ¤388.65 11/07/2022
IMPACT FEE PARKS ¤1,455.13 11/07/2022
IMPACT FEE SCHOOL ¤5,450.00 11/07/2022
IMPACT FEE TRANSPORTATION ¤1,764.00 11/07/2022
WATER -IRRIGATION INSPECTION ¤25.00 11/07/2022
3% PARKS IMPACT FEE CREDIT (¤43.65) 11/07/2022
SURCHARGE FS 533.721 ¤2.69 11/07/2022
SURCHARGE - FS 468.631 ¤4.04 11/07/2022
SW ENG - FOUNDATION SURVEY ¤20.00 11/07/2022
SW ENG INSPECTION 80 ¤80.00 11/07/2022
SW ENG PRE APRON ¤30.00 11/07/2022
CONNECTION FEES ¤1,077.88 11/07/2022
Fees Total Due: ¤0.00 Total Paid: ¤17,561.23