Permit #2022090379

Permit Details

Status: COED

Parcel Id: 07-11-31-7023-00610-0100
CONDITIONED SPACE: 2386 sqft
GARAGE: 566 sqft
OPENED PORCH (WITH ROOF) : 262 sqft
ENCLOSE EXISTING PORCH TO LIVING : 72 sqft
Total Square Footage: 3286 sqft
Block: 00610
Subdivision: -
Job Phone: 386-283-2035
Location Address: 98 WHEATFIELD DR
Type: DU - DUPLEX
Issue Date: 09/26/2022
NOC: RECORDED
Applicant name: OLEG BELINSKIY
Owner: YAGUDAEV RAFAEL

Address

301 BROWNRIDGE DRIVE

VAUGHAN ONTARIO L4J5W7 CANADA, 0

Lot: 0100
Contracted Stated Job Value: ¤350,000.00
Job Description: DUPLEX
Type: CN

Contractor

FLORIDAS BEST BUILDERS INC
Status Location Address State License Number Phone
ACTIVE

19 PINE CIRCLE DRIVE

PALM COAST, FL 32164

CBC1264760 (Exp: 08/31/2026) 386-283-2035

Sub Contractors

OLEG BELINSKIY
Status Location Address State License Number Phone
ACTIVE

19 PINE CIRCLE DRIVE19

PALM COAST, FL 32167

CCC1325974 (Exp: 08/31/2026) 386-263-7906
JUAN CARLOS GONZALEZ
Status Location Address State License Number
ACTIVE

1328 COUNTY ROAD 308

CRESCENT CITY, FL 32112

RF11067806 (Exp: 08/31/2027)
FERNANDO MEZA SR
Status Location Address State License Number Phone
ACTIVE

457 CHELSEA PLACE AVE

ORMOND BEACH, FL 32174

EC13003906 (Exp: 08/31/2026) 386-241-5211
SERGEY SERGEYEVICH KRUGLYAK
Status Location Address State License Number Phone
ACTIVE

50 PINE CREST LN

PALM COAST, FL 32164

CAC1818004 (Exp: 08/31/2026) 386-338-7335

Inspection History

Type Request Date Result Inspector
BLD - BUILDING FINAL 08/29/2023 Disapproved -FEE REQUIRED MKRASKI
Note: 8/29/23 A Side 1. Microwave hood duct joints are required to be sealed and can not be flex 2. Unable to remove/replace air filter 3. Door leading from garage to inside house hits whip for water heater Stopped inspection, not ready did not look at B side 8/23/2023 - PREVIOUS INSPECTION NOTES 8/21/2023 - PREVIOUS INSPECTION NOTES 8/21/23: Inspection stopped. Incomplete inspection. Unit A: 1). 2 kitchen outlets at counter & wall below are not GFCI protected. (within 6ft of water). 2). Laundry outlet is not GFCI protected. 3). Garage door opener outlet is not GFCI protected. 4). AC condenser & AHU - breakers are wrong size. (Over Max amps). 5). Missing Insulation certificate. 6). Dishwasher is not powered. 7). Holes in garage walls at water heater plate, and conduits need to be firestopped. **** Inspection stopped in Unit B - Only smokes, attic insulation height and energy calcs are approved. Will need complete inspection. Many of the same deficiencies as in Unit A.
BLD - BUILDING FINAL 08/29/2023 FINAL APPROVED RMARTIN
Note: 8/29/23 went back in PM and all was fixed 8/29/2023 - PREVIOUS INSPECTION NOTES 8/29/23 A Side 1. Microwave hood duct joints are required to be sealed 2. Unable to remove/replace air filter 3. Door leading from garage to inside house hits whip for water heater Stopped inspection, not ready did not look at B side 8/23/2023 - PREVIOUS INSPECTION NOTES 8/21/2023 - PREVIOUS INSPECTION NOTES 8/21/23: Inspection stopped. Incomplete inspection. Unit A: 1). 2 kitchen outlets at counter & wall below are not GFCI protected. (within 6ft of water). 2). Laundry outlet is not GFCI protected. 3). Garage door opener outlet is not GFCI protected. 4). AC condenser & AHU - breakers are wrong size. (Over Max amps). 5). Missing Insulation certificate. 6). Dishwasher is not powered. 7). Holes in garage walls at water heater plate, and conduits need to be firestopped. **** Inspection stopped in Unit B - Only smokes, attic insulation height and energy calcs are approved. Will need complete inspection. Many of the same deficiencies as in Unit A.
BLD - BUILDING FINAL 08/23/2023 CANCELLED BY APPLICANT MKRASKI
Note: 8/21/2023 - PREVIOUS INSPECTION NOTES 8/21/23: Inspection stopped. Incomplete inspection. Unit A: 1). 2 kitchen outlets at counter & wall below are not GFCI protected. (within 6ft of water). 2). Laundry outlet is not GFCI protected. 3). Garage door opener outlet is not GFCI protected. 4). AC condenser & AHU - breakers are wrong size. (Over Max amps). 5). Missing Insulation certificate. 6). Dishwasher is not powered. 7). Holes in garage walls at water heater plate, and conduits need to be firestopped. **** Inspection stopped in Unit B - Only smokes, attic insulation height and energy calcs are approved. Will need complete inspection. Many of the same deficiencies as in Unit A.
BLD - BUILDING FINAL 08/21/2023 Disapproved -FEE REQUIRED RSIMS
Note: 8/21/23: Inspection stopped. Incomplete inspection. Unit A: 1). 2 kitchen outlets at counter & wall below are not GFCI protected. (within 6ft of water). 2). Laundry outlet is not GFCI protected. 3). Garage door opener outlet is not GFCI protected. 4). AC condenser & AHU - breakers are wrong size. (Over Max amps). 5). Missing Insulation certificate. 6). Dishwasher is not powered. 7). Holes in garage walls at water heater plate, and conduits need to be firestopped. **** Inspection stopped in Unit B - Only smokes, attic insulation height and energy calcs are approved. Will need complete inspection. Many of the same deficiencies as in Unit A.
ROW - FINAL INSPECTION 08/17/2023 FINAL APPROVED FSLADISH
Note: 08/17/23 CORRECTIONS MADE. EVERYTHING LOOKED GOOD AT THE TIME OF THIS INSPECTION. _________________________________________________________________________________________________________________________ 8/16/2023 - PREVIOUS INSPECTION NOTES 08/16/23 THERE IS STILL QUITE A BIT OF TRASH AND CONSTRUCTION DEBRIS ON SITE ESPECIALLY IN THE REAR ON THE BACK PATIOS. THIS AND ALL TRASH AND DEBRIS ON SITE AND VACANT MUST BE CLEANED UP BEFORE ROW FINAL WILL BE PASSED. NOT GOING TO FEE YOU FOR THIS INSPECTION AS I WAS HERE ALREADY FOR AFTER POUR. PLEASE MAKE CORRECTIONS BEFORE SCHEDULING FINAL.
U -UTILITY RESIDENTIAL FINAL 08/16/2023 Disapproved - NO FEE LFITZGERALD
Note: it was observed that there was purple pipe coming out of the potable water meter assembly for the water service to the reidence-which if this the case is a building violation - Statement from Patric Buckley-City Building Official-"After viewing the picture provided, the “purple pipe” used is a violation of the Florida Plumbing Code Section 608.9.2. It is also likely a violation of Section 605.3 which establishes the material standards for water service piping. I recommend having the contractor dig up both service lines sufficient to see labeling that proves the water service conforms to the following: Plastic Pipe must be: CPVC Must conform to: ASTM D2846, ASTM F441, or ASTM F442 Must conform to: NSF – 61 Must be temperature rated for 160 Degrees Pipe must be labeled showing all the above information. If the pipe cannot be verified to comply they will need to replace it in its entirety. Please contact the plumbing inspector-Mark Gibson for this inspection
U -UTILITY RESIDENTIAL FINAL 08/16/2023 APPROVED - AS NOTED LFITZGERALD
Note: After further inspection ,it was confirmed that it was purple primer that was covering the piece of pipe in the water meter pit. 8/16/2023 - PREVIOUS INSPECTION NOTES it was observed that there was purple pipe coming out of the potable water meter assembly for the water service to the reidence-which if this the case is a building violation - Statement from Patric Buckley-City Building Official-"After viewing the picture provided, the “purple pipe” used is a violation of the Florida Plumbing Code Section 608.9.2. It is also likely a violation of Section 605.3 which establishes the material standards for water service piping. I recommend having the contractor dig up both service lines sufficient to see labeling that proves the water service conforms to the following: Plastic Pipe must be: CPVC Must conform to: ASTM D2846, ASTM F441, or ASTM F442 Must conform to: NSF – 61 Must be temperature rated for 160 Degrees Pipe must be labeled showing all the above information. If the pipe cannot be verified to comply they will need to replace it in its entirety. Please contact the plumbing inspector-Mark Gibson for this inspection
ROW - FINAL INSPECTION 08/16/2023 Disapproved - NO FEE FSLADISH
Note: 08/16/23 THERE IS STILL QUITE A BIT OF TRASH AND CONSTRUCTION DEBRIS ON SITE ESPECIALLY IN THE REAR ON THE BACK PATIOS. THIS AND ALL TRASH AND DEBRIS ON SITE AND VACANT MUST BE CLEANED UP BEFORE ROW FINAL WILL BE PASSED. NOT GOING TO FEE YOU FOR THIS INSPECTION AS I WAS HERE ALREADY FOR AFTER POUR. PLEASE MAKE CORRECTIONS BEFORE SCHEDULING FINAL.
ROW - FINAL APRON (AFTER POUR) 08/16/2023 APPROVED FSLADISH
Note: 08/16/23 PIPE IS GOOD. CUTS MADE. CULVERT CLEAR. LOOKED GOOD AT TIME OF INSPECTION.
ROW FIELD SURVEY /GRADING CERTIFICATION 08/15/2023 APPROVED GBERTOLA
Note: 8/15/23= CORRECTION WERE MADE +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 8/9/2023 - PREVIOUS INSPECTION NOTES 08/09/23 RIGHT SIDE SWALE IS TOO HIGH NEEDS TO BE LOWERED TO MATCH GRADE. IT IS SHOWING 28.20 AT RIGHT PROPERTY LINE THEN IT IS GOING UP HILL TO 28.30 TO 28.40 ALL THE WAY TO THE CULVERT END. THIS NEEDS TO RUN FLAT FROM THAT PROPERTY LINE TO THE CULVERT END. LEFT SIDE IS HIGH AS WELL WITH NO REAL SWALE. AREAS ARE PAINTED. IF TOU DO NOT UNDERSTAND WHAT IS REQUIRED PLEASE CALL US AND SET UP A SITE MEET. THE FRONT SWALE IS NOT CORRECT AND NEEDS TO BE ADDRESSED BEFORE MOVING FORWARD. THE CENTER OF THE SWALE AT THE BOTTOM IS TO BE 8 FT FROM THE EDGE OF THE ROAD. PLEASE REFER TO THE SWALE PLAN DETAIL PROVIDE TO YOU WHEN YOR PERMIT WAS ISSUED FOR ALL SWALE REQUIREMENTS. SWALE PLAN DRAWING #300.D. 8/7/2023 - PREVIOUS INSPECTION NOTES 8/7/23= NEED TO READ THE INPECTOR NOTE NEED TO LOWER THE RIGHT SIDE SWALE. MATCH EXISTING GRADE NEED TO REMOVE THE CONCRETE ON THE RIGHT SIDE SWALE 7/31/2023 - PREVIOUS INSPECTION NOTES 07/31/23 UPON WALKING THE PROPERTY SEEMS TO BE SOME LOW SPOTS AND INCONSISTENCY MOVING FORWARD OF DRAINAGE FROM REAR TO FRONT ON RIGHT SIDE PROPERTY LINE. FINAL GRADE NEED TO BE 2" BELOW THE EDGE OF THE ROAD TO ALLOW WATER TO DRAIN OFF OF ROAD INTO SWALE. IT IS TOO HIGH. NEED TO MOVE PORTA POTTY AND CONCRETE CLEANOUT TAILINGS FROM RIGHT SIDE OF SWALE THEY ARE IMPEDEING THE DRAINAGE FLOW..
ROW FIELD SURVEY /GRADING CERTIFICATION 08/09/2023 Disapproved - NO FEE FSLADISH
Note: 08/09/23 RIGHT SIDE SWALE IS TOO HIGH NEEDS TO BE LOWERED TO MATCH GRADE. IT IS SHOWING 28.20 AT RIGHT PROPERTY LINE THEN IT IS GOING UP HILL TO 28.30 TO 28.40 ALL THE WAY TO THE CULVERT END. THIS NEEDS TO RUN FLAT FROM THAT PROPERTY LINE TO THE CULVERT END. LEFT SIDE IS HIGH AS WELL WITH NO REAL SWALE. AREAS ARE PAINTED. IF TOU DO NOT UNDERSTAND WHAT IS REQUIRED PLEASE CALL US AND SET UP A SITE MEET. THE FRONT SWALE IS NOT CORRECT AND NEEDS TO BE ADDRESSED BEFORE MOVING FORWARD. THE CENTER OF THE SWALE AT THE BOTTOM IS TO BE 8 FT FROM THE EDGE OF THE ROAD. PLEASE REFER TO THE SWALE PLAN DETAIL PROVIDE TO YOU WHEN YOR PERMIT WAS ISSUED FOR ALL SWALE REQUIREMENTS. SWALE PLAN DRAWING #300.D. 8/7/2023 - PREVIOUS INSPECTION NOTES 8/7/23= NEED TO READ THE INPECTOR NOTE NEED TO LOWER THE RIGHT SIDE SWALE. MATCH EXISTING GRADE NEED TO REMOVE THE CONCRETE ON THE RIGHT SIDE SWALE 7/31/2023 - PREVIOUS INSPECTION NOTES 07/31/23 UPON WALKING THE PROPERTY SEEMS TO BE SOME LOW SPOTS AND INCONSISTENCY MOVING FORWARD OF DRAINAGE FROM REAR TO FRONT ON RIGHT SIDE PROPERTY LINE. FINAL GRADE NEED TO BE 2" BELOW THE EDGE OF THE ROAD TO ALLOW WATER TO DRAIN OFF OF ROAD INTO SWALE. IT IS TOO HIGH. NEED TO MOVE PORTA POTTY AND CONCRETE CLEANOUT TAILINGS FROM RIGHT SIDE OF SWALE THEY ARE IMPEDEING THE DRAINAGE FLOW..
ROW FIELD SURVEY /GRADING CERTIFICATION 08/07/2023 Disapproved -FEE REQUIRED GBERTOLA
Note: 8/7/23= NEED TO READ THE INPECTOR NOTE NEED TO LOWER THE RIGHT SIDE SWALE. MATCH EXISTING GRADE NEED TO REMOVE THE CONCRETE ON THE RIGHT SIDE SWALE 7/31/2023 - PREVIOUS INSPECTION NOTES 07/31/23 UPON WALKING THE PROPERTY SEEMS TO BE SOME LOW SPOTS AND INCONSISTENCY MOVING FORWARD OF DRAINAGE FROM REAR TO FRONT ON RIGHT SIDE PROPERTY LINE. FINAL GRADE NEED TO BE 2" BELOW THE EDGE OF THE ROAD TO ALLOW WATER TO DRAIN OFF OF ROAD INTO SWALE. IT IS TOO HIGH. NEED TO MOVE PORTA POTTY AND CONCRETE CLEANOUT TAILINGS FROM RIGHT SIDE OF SWALE THEY ARE IMPEDEING THE DRAINAGE FLOW..
ROW- FINAL SURVEY/GRADING CERTIFICATION 07/31/2023 APPROVED FSLADISH
ROW FIELD SURVEY /GRADING CERTIFICATION 07/31/2023 Disapproved - NO FEE FSLADISH
Note: 07/31/23 UPON WALKING THE PROPERTY SEEMS TO BE SOME LOW SPOTS AND INCONSISTENCY MOVING FORWARD OF DRAINAGE FROM REAR TO FRONT ON RIGHT SIDE PROPERTY LINE. THE SOD NEEDS TO BE 2" BELOW THE EDGE OF THE ROAD TO ALLOW WATER TO DRAIN OFF OF ROAD INTO SWALE. IT IS TOO HIGH. NEED TO MOVE PORTA POTTY AND CONCRETE CLEANOUT TAILINGS FROM RIGHT SIDE OF SWALE THEY ARE IMPEDEING THE DRAINAGE FLOW..
ROW- PRE-APRON (PRE-POUR) 06/22/2023 APPROVED PFLANAGAN
Note: IT'S YOUR RESPONSIBILITY TO CHECK THE CULVERT PIPE ELEVATIONS BEFORE POURING CONCRETE FOR THE DRIVEWAY. ALL CONCRETE NEEDS TO BE A MINIMUM OF 3000PSI WITH FIBER OR WITH METAL MESH IN THE POURING AREA. At the time of the inspection all minimum city requirements were met. It is the builders responsibiliy to ensure that nothing changes after this Inspection is approved. -------------------------------------------------------------------------------------------------------------------- 6/21/2023 - PREVIOUS INSPECTION NOTES 6/21/23= FOOTERS HAVE WASHED IN NEED TO BE DUG OUT BOTH SIDES, PICTURE ATTACHED CULVERT PIPE ELEVATION AT TIME OF THE INSPECTION IS OK .PICTURE ATTACHED ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 6/20/2023 - PREVIOUS INSPECTION NOTES 6/20/23= NOTHING HAS BEEN DONE SINCE THE LAST INSPECTION, NEED TO READ THE INPECTOR NOTE. APRON IS SOFT PICTURE ATTACHED. +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 6/16/2023 - PREVIOUS INSPECTION NOTES 06/16/23= FOOTERS HAVE WASHED IN NEED TO BE DUG OUT BOTH SIDES , 300 E RESIDENTIAL CULVERT DETAIL CULVERT PIPE ELEVATION IS GOOD PICTURE ATTACHED
ROW- PRE-APRON (PRE-POUR) 06/21/2023 Disapproved -FEE REQUIRED GBERTOLA
Note: 6/21/23= FOOTERS HAVE WASHED IN NEED TO BE DUG OUT BOTH SIDES, PICTURE ATTACHED CULVERT PIPE ELEVATION AT TIME OF THE INSPECTION IS OK .PICTURE ATTACHED ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 6/20/2023 - PREVIOUS INSPECTION NOTES 6/20/23= NOTHING HAS BEEN DONE SINCE THE LAST INSPECTION, NEED TO READ THE INPECTOR NOTE. APRON IS SOFT PICTURE ATTACHED. +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 6/16/2023 - PREVIOUS INSPECTION NOTES 06/16/23= FOOTERS HAVE WASHED IN NEED TO BE DUG OUT BOTH SIDES , 300 E RESIDENTIAL CULVERT DETAIL CULVERT PIPE ELEVATION IS GOOD PICTURE ATTACHED
ROW- PRE-APRON (PRE-POUR) 06/20/2023 Disapproved -FEE REQUIRED GBERTOLA
Note: 6/20/23= NOTHING HAS BEEN DONE SINCE THE LAST INSPECTION, NEED TO READ THE INPECTOR NOTE. APRON IS SOFT PICTURE ATTACHED. +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 6/16/2023 - PREVIOUS INSPECTION NOTES 06/16/23= FOOTERS HAVE WASHED IN NEED TO BE DUG OUT BOTH SIDES , 300 E RESIDENTIAL CULVERT DETAIL CULVERT PIPE ELEVATION IS GOOD PICTURE ATTACHED
U-CROSS CONNECTION 06/16/2023 APPROVED - AS NOTED JHARDING
Note: No irrigation, no cross connections
ROW- PRE-APRON (PRE-POUR) 06/16/2023 Disapproved -FEE REQUIRED GBERTOLA
Note: 06/16/23= FOOTERS HAVE WASHED IN NEED TO BE DUG OUT BOTH SIDES , 300 E RESIDENTIAL CULVERT DETAIL CULVERT PIPE ELEVATION IS GOOD PICTURE ATTACHED
ELECTRIC - EARLY POWER 06/12/2023 APPROVED - AS NOTED MKRASKI
Note: Emailed FPL @ 2 PM
ELECTRIC - EARLY POWER 06/06/2023 Disapproved - NO FEE MKRASKI
Note: Overhead service wires are required to be sunlight resistant NEC 310.10(d)
GRAVITY SEWER TEST 05/31/2023 APPROVED MGIBSON
U - SEWER TIE IN 05/31/2023 APPROVED MGIBSON
PEP TANK INSTALLATION REQUEST 05/18/2023 APPROVED CSTONE
INSULATION 04/19/2023 APPROVED RMARTIN
Note: 4/17/2023 - PREVIOUS INSPECTION NOTES 4/17/23 1. Door locked need access for inspection 2. Water heater has not be relocated 3. Insulation blown out of garage wall 3/29/2023 - PREVIOUS INSPECTION NOTES Water heater can not be in front of electrical panel min of 3' working space is require for panel NEC 110.26
INSULATION 04/17/2023 Disapproved -FEE REQUIRED MKRASKI
Note: 4/17/23 1. Door locked need access for inspection 2. Water heater has not be relocated 3. Insulation blown out of garage wall 3/29/2023 - PREVIOUS INSPECTION NOTES Water heater can not be in front of electrical panel min of 3' working space is require for panel NEC 110.26
INSULATION 03/29/2023 Disapproved - NO FEE MKRASKI
Note: Water heater can not be in front of electrical panel min of 3' working space is require for panel NEC 110.26
LATH/BRICK/ WATER BARRIER 03/29/2023 APPROVED MKRASKI
LATH/BRICK/ WATER BARRIER 03/22/2023 Disapproved - NO FEE MKRASKI
Note: 1. Holes in block need lath 2. Meter main not installed
INSULATION 03/22/2023 Disapproved -FEE REQUIRED MKRASKI
Note: 3/22/23 1. Previous items not repaired 2. Meter main not installed 3/20/2023 - PREVIOUS INSPECTION NOTES 1. Both units, garage wood frame wall needs to be sealed at base and edges 2. B side penitration needs to be fire foamed where door bell wiring for chime is located
INSULATION 03/20/2023 Disapproved - NO FEE MKRASKI
Note: 1. Both units, garage wood frame wall needs to be sealed at base and edges 2. B side penitration needs to be fire foamed where door bell wiring for chime is located
FIREWALL FINAL 03/16/2023 APPROVED TSTAUFFACHER
Note: 3/13/2023 - PREVIOUS INSPECTION NOTES High and low voltage chase's not installed yet, chase's need to be installed, wire pulled, and fire caulked before final
ALL ROUGH 03/16/2023 APPROVED TSTAUFFACHER
FIREWALL FINAL 03/13/2023 Disapproved - NO FEE MKRASKI
Note: High and low voltage chase's not installed yet, chase's need to be installed, wire pulled, and fire caulked before final
WALL SHEATHING 03/13/2023 CANCELLED BY INSPECTOR MKRASKI
Note: Inspection not needed
FIREWALL DRYWALL NAILING 03/09/2023 APPROVED MKRASKI
FIREWALL DRYWALL NAILING 03/08/2023 CANCELLED BY APPLICANT WEB
FIREWALL DRYWALL NAILING 03/07/2023 CANCELLED BY APPLICANT WEB
ROOF VALLEY & METAL 02/24/2023 APPROVED MKRASKI
ROOF SHEATHING / BRACES/TIES/DOWN CELL 02/17/2023 APPROVED FWILLIS
Note: 2/13/2023 - PREVIOUS INSPECTION NOTES 2/13/23 A and B side 1. Interior non load bearing wall not attached to CMU per plans or can not see 2. Truss strap missing on A side front entry marked on print SIDE NOTE: LEFT UNIT HAS 5 RETRO-FITTED TWIST STRAPS. STRAPS ARE WOOD STRAPS, NOT WOOD TO MASONRY STRAPS. Did not check truss engineering 2/9/2023 - PREVIOUS INSPECTION NOTES A side 1. Interior non load bearing wall not attached to CMU per plans or can not see 2. Truss strap missing on A side front entry marked on print 3. Can not see truss straps on back of A side marked on print Stopped inspection on A side re-check all truss strapping, did not look at B side at all
ROOF SHEATHING / BRACES/TIES/DOWN CELL 02/13/2023 Disapproved -FEE REQUIRED MKRASKI
Note: 2/13/23 A and B side 1. Interior non load bearing wall not attached to CMU per plans or can not see 2. Truss strap missing on A side front entry marked on print Did not check truss engineering 2/9/2023 - PREVIOUS INSPECTION NOTES A side 1. Interior non load bearing wall not attached to CMU per plans or can not see 2. Truss strap missing on A side front entry marked on print 3. Can not see truss straps on back of A side marked on print Stopped inspection on A side re-check all truss strapping, did not look at B side at all
ROOF SHEATHING / BRACES/TIES/DOWN CELL 02/09/2023 Disapproved - NO FEE MKRASKI
Note: A side 1. Interior non load bearing wall not attached to CMU per plans or can not see 2. Truss strap missing on A side front entry marked on print 3. Can not see truss straps on back of A side marked on print Stopped inspection on A side re-check all truss strapping, did not look at B side at all
TIE BEAM / LINTEL 01/09/2023 APPROVED MKRASKI
FOUND SURVEY APPROVED (OFFICE) 12/07/2022 APPROVED TBAKER
MONOLITHIC SLAB 11/21/2022 APPROVED MKRASKI
Note:
MONOLITHIC SLAB 11/17/2022 Disapproved -FEE REQUIRED MKRASKI
Note: 11/17/22 STILL no compaction paperwork 11/16/2022 - PREVIOUS INSPECTION NOTES No compaction paperwork on site FBC 404.1 Stopped inspection
MONOLITHIC SLAB 11/16/2022 Disapproved - NO FEE MKRASKI
Note: No compaction paperwork on site FBC 404.1 Stopped inspection
PLUMBING 1ST ROUGH UNDERGROUND 11/01/2022 APPROVED MGIBSON
WATER METER INSTALLATION REQUEST 10/18/2022 APPROVED CSTONE

Review History

Department Status Date In Date Out
MECH COMPLETE 08/16/2023 08/18/2023
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
MECH HOLD 08/14/2023 08/15/2023
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM 1. Energy Calcs need to be signed by the owner/ owner agent below the preparer per R103.1.1.2 FBC Energy Conservation 2020 7Th edition 2. Duct layout needs to be signed by the AC contractor per 107.1 FBC Residential 2020 7th Edition
BADMIN INFORMATION 03/06/2023 03/06/2023
Note: Marked INFORMATION By: SCOTT THOMAS - - STHOMAS@PALMCOASTGOV.COM SUBMIT PROD APP SHEET
BLD COMPLETE 03/06/2023 03/07/2023
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
ENGIN1 COMPLETE 02/24/2023 02/24/2023
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
BLD COMPLETE 02/24/2023 03/03/2023
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
ELEC COMPLETE 02/24/2023 02/24/2023
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
BLD COMPLETE 02/15/2023 02/16/2023
Note: Released By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM
BLD HOLD 02/09/2023 02/15/2023
Note: Held By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM All comments below per the 2020 Florida Building Code PLAN REVIEW COMMENTS: 1. ESR-1338 is if the 1-hour wall designed using the Gypsum Associations design. A revision to the UL Listing is required or revise the Fire Wall Design.
ENGIN1 HOLD 12/07/2022 12/07/2022
Note: Held By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
ZON COMPLETE 12/07/2022 12/07/2022
Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM
MECH COMPLETE 09/16/2022 09/16/2022
Note: Released By: CHRIS PISCITELLI - (386)986-3782 - CPISCITELLI@PALMCOASTGOV.COM
BLD COMPLETE 09/16/2022 09/19/2022
Note: Released By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM
BLD HOLD 09/09/2022 09/13/2022
Note: Held By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM PLAN REVIEW COMMENTS: Repeat Comments 1. Product Approval Specification Sheet; a. Product Approval for the proposed underlayment on the Roofing Worksheet does not match the Product Approval Sheet. Revise to reflect the correct underlayment to be used. Per F.S. 471.025 and F.A.C. 61 G15-23.005.
CUSVC COMPLETE 09/09/2022 09/13/2022
Note: Released By: HALEIGH HAND - -
ELEC COMPLETE 09/09/2022 09/09/2022
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
ENGIN1 COMPLETE 09/09/2022 09/09/2022
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
LOCATE COMPLETE 09/09/2022 09/14/2022
Note: Released By: CANDACE STONE - - CSTONE@PALMCOASTGOV.COM
MECH HOLD 09/09/2022 09/09/2022
Note: Held By: CHRIS PISCITELLI - (386)986-3782 - CPISCITELLI@PALMCOASTGOV.COM 1. Energy Calcs need to be signed by the builder per 107.1 FBC Residential 2020 7th edition 2. Plans show common wall CMU. Energy calcs say Frame. Revise to match
SW1 COMPLETE 09/09/2022 09/16/2022
Note: Released By: ROBERT GROSS - (386)986-4769 - RGROSS@PALMCOASTGOV.COM
ZON COMPLETE 09/09/2022 09/15/2022
Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM Landscape plan: missing please provide a plan
SWALE COMPLETE 09/09/2022 01/05/2023
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
PLAN REVIEW - REVISION ¤32.50 08/29/2023
REINSPECTION RESIDENTIAL ¤40.00 08/29/2023
REINSPECTION RESIDENTIAL ¤40.00 08/29/2023
SW ENG REINSPECTION 20 ¤20.00 08/09/2023
SW ENG REINSPECTION 30 ¤30.00 06/21/2023
SW ENG REINSPECTION 30 ¤30.00 06/20/2023
SW ENG REINSPECTION 30 ¤30.00 06/20/2023
REINSPECTION RESIDENTIAL ¤40.00 04/19/2023
REINSPECTION RESIDENTIAL ¤40.00 03/22/2023
REINSPECTION RESIDENTIAL ¤40.00 02/23/2023
CONTRACTOR CHANGE ¤20.00 02/08/2023
CONTRACTOR CHANGE ¤20.00 02/08/2023
REINSPECTION RESIDENTIAL ¤40.00 12/07/2022
IMPACT FEE SCHOOL ¤3,700.00 10/10/2022
IMPACT FEE SCHOOL ¤7,200.00 09/26/2022
IMPACT FEE TRANSPORTATION ¤2,738.00 09/26/2022
WATER -IRRIGATION INSPECTION ¤50.00 09/26/2022
3% PARKS IMPACT FEE CREDIT (¤87.31) 09/26/2022
SURCHARGE FS 533.721 ¤4.00 09/26/2022
SURCHARGE - FS 468.631 ¤6.00 09/26/2022
SW ENG - FOUNDATION SURVEY ¤20.00 09/26/2022
SW ENG INSPECTION 80 ¤80.00 09/26/2022
SW ENG PRE APRON ¤30.00 09/26/2022
SW ENG - REVIEW 20 ¤20.00 09/26/2022
SW ENG RES REVIEW 200 ¤200.00 09/26/2022
3% TRANS IMPACT FEE CREDIT (¤82.14) 09/26/2022
SEWER CREDIT (¤2,016.00) 09/26/2022
SEWER INSPECTION ¤25.00 09/26/2022
SEWER CAPITAL FACILITY ¤9,879.52 09/26/2022
WATER CAPITAL FACILITY FEE ¤7,253.00 09/26/2022
SITE PLAN 30 ¤30.00 09/26/2022
WATER- TURN ON ¤50.00 09/26/2022
ADJUSTMENT 50% (¤632.75) 09/26/2022
ADMINISTRATIVE RESIDENTIAL ¤30.00 09/26/2022
INSPECTION - RESIDENTIAL ¤962.50 09/26/2022
PLAN REVIEW - RESIDENTIAL ¤273.00 09/26/2022
3% FIRE IMPACT FEE CREDIT (¤23.32) 09/26/2022
IMPACT FEE FIRE ¤777.30 09/26/2022
IMPACT FEE PARKS ¤2,910.26 09/26/2022
CONNECTION FEES ¤2,155.76 09/26/2022
Fees Total Due: ¤0.00 Total Paid: ¤35,975.32