I want to search for...
Permit #2022090379
Permit Details
Status: COED
| Parcel Id: 07-11-31-7023-00610-0100 |
| CONDITIONED SPACE: 2386 sqft |
| GARAGE: 566 sqft |
| OPENED PORCH (WITH ROOF) : 262 sqft |
| ENCLOSE EXISTING PORCH TO LIVING : 72 sqft |
| Total Square Footage: 3286 sqft |
| Block: 00610 |
| Subdivision: - |
| Job Phone: 386-283-2035 |
| Location Address: 98 WHEATFIELD DR |
| Type: DU - DUPLEX |
| Issue Date: 09/26/2022 |
| NOC: RECORDED |
| Applicant name: OLEG BELINSKIY |
| Owner: YAGUDAEV RAFAEL |
|
Address 301 BROWNRIDGE DRIVE VAUGHAN ONTARIO L4J5W7 CANADA, 0 |
| Lot: 0100 |
| Contracted Stated Job Value: ¤350,000.00 |
| Job Description: DUPLEX |
| Type: CN |
Contractor
FLORIDAS BEST BUILDERS INC
| Status | Location Address | State License Number | Phone |
| ACTIVE |
19 PINE CIRCLE DRIVE PALM COAST, FL 32164 |
CBC1264760 (Exp: 08/31/2026) | 386-283-2035 |
Sub Contractors
OLEG BELINSKIY
| Status | Location Address | State License Number | Phone |
| ACTIVE |
19 PINE CIRCLE DRIVE19 PALM COAST, FL 32167 |
CCC1325974 (Exp: 08/31/2026) | 386-263-7906 |
JUAN CARLOS GONZALEZ
| Status | Location Address | State License Number |
| ACTIVE |
1328 COUNTY ROAD 308 CRESCENT CITY, FL 32112 |
RF11067806 (Exp: 08/31/2027) |
FERNANDO MEZA SR
| Status | Location Address | State License Number | Phone |
| ACTIVE |
457 CHELSEA PLACE AVE ORMOND BEACH, FL 32174 |
EC13003906 (Exp: 08/31/2026) | 386-241-5211 |
SERGEY SERGEYEVICH KRUGLYAK
| Status | Location Address | State License Number | Phone |
| ACTIVE |
50 PINE CREST LN PALM COAST, FL 32164 |
CAC1818004 (Exp: 08/31/2026) | 386-338-7335 |
Inspection History
| Type | Request Date | Result | Inspector |
| BLD - BUILDING FINAL | 08/29/2023 | Disapproved -FEE REQUIRED | MKRASKI |
| Note: 8/29/23 A Side 1. Microwave hood duct joints are required to be sealed and can not be flex 2. Unable to remove/replace air filter 3. Door leading from garage to inside house hits whip for water heater Stopped inspection, not ready did not look at B side 8/23/2023 - PREVIOUS INSPECTION NOTES 8/21/2023 - PREVIOUS INSPECTION NOTES 8/21/23: Inspection stopped. Incomplete inspection. Unit A: 1). 2 kitchen outlets at counter & wall below are not GFCI protected. (within 6ft of water). 2). Laundry outlet is not GFCI protected. 3). Garage door opener outlet is not GFCI protected. 4). AC condenser & AHU - breakers are wrong size. (Over Max amps). 5). Missing Insulation certificate. 6). Dishwasher is not powered. 7). Holes in garage walls at water heater plate, and conduits need to be firestopped. **** Inspection stopped in Unit B - Only smokes, attic insulation height and energy calcs are approved. Will need complete inspection. Many of the same deficiencies as in Unit A. | |||
| BLD - BUILDING FINAL | 08/29/2023 | FINAL APPROVED | RMARTIN |
| Note: 8/29/23 went back in PM and all was fixed 8/29/2023 - PREVIOUS INSPECTION NOTES 8/29/23 A Side 1. Microwave hood duct joints are required to be sealed 2. Unable to remove/replace air filter 3. Door leading from garage to inside house hits whip for water heater Stopped inspection, not ready did not look at B side 8/23/2023 - PREVIOUS INSPECTION NOTES 8/21/2023 - PREVIOUS INSPECTION NOTES 8/21/23: Inspection stopped. Incomplete inspection. Unit A: 1). 2 kitchen outlets at counter & wall below are not GFCI protected. (within 6ft of water). 2). Laundry outlet is not GFCI protected. 3). Garage door opener outlet is not GFCI protected. 4). AC condenser & AHU - breakers are wrong size. (Over Max amps). 5). Missing Insulation certificate. 6). Dishwasher is not powered. 7). Holes in garage walls at water heater plate, and conduits need to be firestopped. **** Inspection stopped in Unit B - Only smokes, attic insulation height and energy calcs are approved. Will need complete inspection. Many of the same deficiencies as in Unit A. | |||
| BLD - BUILDING FINAL | 08/23/2023 | CANCELLED BY APPLICANT | MKRASKI |
| Note: 8/21/2023 - PREVIOUS INSPECTION NOTES 8/21/23: Inspection stopped. Incomplete inspection. Unit A: 1). 2 kitchen outlets at counter & wall below are not GFCI protected. (within 6ft of water). 2). Laundry outlet is not GFCI protected. 3). Garage door opener outlet is not GFCI protected. 4). AC condenser & AHU - breakers are wrong size. (Over Max amps). 5). Missing Insulation certificate. 6). Dishwasher is not powered. 7). Holes in garage walls at water heater plate, and conduits need to be firestopped. **** Inspection stopped in Unit B - Only smokes, attic insulation height and energy calcs are approved. Will need complete inspection. Many of the same deficiencies as in Unit A. | |||
| BLD - BUILDING FINAL | 08/21/2023 | Disapproved -FEE REQUIRED | RSIMS |
| Note: 8/21/23: Inspection stopped. Incomplete inspection. Unit A: 1). 2 kitchen outlets at counter & wall below are not GFCI protected. (within 6ft of water). 2). Laundry outlet is not GFCI protected. 3). Garage door opener outlet is not GFCI protected. 4). AC condenser & AHU - breakers are wrong size. (Over Max amps). 5). Missing Insulation certificate. 6). Dishwasher is not powered. 7). Holes in garage walls at water heater plate, and conduits need to be firestopped. **** Inspection stopped in Unit B - Only smokes, attic insulation height and energy calcs are approved. Will need complete inspection. Many of the same deficiencies as in Unit A. | |||
| ROW - FINAL INSPECTION | 08/17/2023 | FINAL APPROVED | FSLADISH |
| Note: 08/17/23 CORRECTIONS MADE. EVERYTHING LOOKED GOOD AT THE TIME OF THIS INSPECTION. _________________________________________________________________________________________________________________________ 8/16/2023 - PREVIOUS INSPECTION NOTES 08/16/23 THERE IS STILL QUITE A BIT OF TRASH AND CONSTRUCTION DEBRIS ON SITE ESPECIALLY IN THE REAR ON THE BACK PATIOS. THIS AND ALL TRASH AND DEBRIS ON SITE AND VACANT MUST BE CLEANED UP BEFORE ROW FINAL WILL BE PASSED. NOT GOING TO FEE YOU FOR THIS INSPECTION AS I WAS HERE ALREADY FOR AFTER POUR. PLEASE MAKE CORRECTIONS BEFORE SCHEDULING FINAL. | |||
| U -UTILITY RESIDENTIAL FINAL | 08/16/2023 | Disapproved - NO FEE | LFITZGERALD |
| Note: it was observed that there was purple pipe coming out of the potable water meter assembly for the water service to the reidence-which if this the case is a building violation - Statement from Patric Buckley-City Building Official-"After viewing the picture provided, the “purple pipe” used is a violation of the Florida Plumbing Code Section 608.9.2. It is also likely a violation of Section 605.3 which establishes the material standards for water service piping. I recommend having the contractor dig up both service lines sufficient to see labeling that proves the water service conforms to the following: Plastic Pipe must be: CPVC Must conform to: ASTM D2846, ASTM F441, or ASTM F442 Must conform to: NSF – 61 Must be temperature rated for 160 Degrees Pipe must be labeled showing all the above information. If the pipe cannot be verified to comply they will need to replace it in its entirety. Please contact the plumbing inspector-Mark Gibson for this inspection | |||
| U -UTILITY RESIDENTIAL FINAL | 08/16/2023 | APPROVED - AS NOTED | LFITZGERALD |
| Note: After further inspection ,it was confirmed that it was purple primer that was covering the piece of pipe in the water meter pit. 8/16/2023 - PREVIOUS INSPECTION NOTES it was observed that there was purple pipe coming out of the potable water meter assembly for the water service to the reidence-which if this the case is a building violation - Statement from Patric Buckley-City Building Official-"After viewing the picture provided, the “purple pipe” used is a violation of the Florida Plumbing Code Section 608.9.2. It is also likely a violation of Section 605.3 which establishes the material standards for water service piping. I recommend having the contractor dig up both service lines sufficient to see labeling that proves the water service conforms to the following: Plastic Pipe must be: CPVC Must conform to: ASTM D2846, ASTM F441, or ASTM F442 Must conform to: NSF – 61 Must be temperature rated for 160 Degrees Pipe must be labeled showing all the above information. If the pipe cannot be verified to comply they will need to replace it in its entirety. Please contact the plumbing inspector-Mark Gibson for this inspection | |||
| ROW - FINAL INSPECTION | 08/16/2023 | Disapproved - NO FEE | FSLADISH |
| Note: 08/16/23 THERE IS STILL QUITE A BIT OF TRASH AND CONSTRUCTION DEBRIS ON SITE ESPECIALLY IN THE REAR ON THE BACK PATIOS. THIS AND ALL TRASH AND DEBRIS ON SITE AND VACANT MUST BE CLEANED UP BEFORE ROW FINAL WILL BE PASSED. NOT GOING TO FEE YOU FOR THIS INSPECTION AS I WAS HERE ALREADY FOR AFTER POUR. PLEASE MAKE CORRECTIONS BEFORE SCHEDULING FINAL. | |||
| ROW - FINAL APRON (AFTER POUR) | 08/16/2023 | APPROVED | FSLADISH |
| Note: 08/16/23 PIPE IS GOOD. CUTS MADE. CULVERT CLEAR. LOOKED GOOD AT TIME OF INSPECTION. | |||
| ROW FIELD SURVEY /GRADING CERTIFICATION | 08/15/2023 | APPROVED | GBERTOLA |
| Note: 8/15/23= CORRECTION WERE MADE +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 8/9/2023 - PREVIOUS INSPECTION NOTES 08/09/23 RIGHT SIDE SWALE IS TOO HIGH NEEDS TO BE LOWERED TO MATCH GRADE. IT IS SHOWING 28.20 AT RIGHT PROPERTY LINE THEN IT IS GOING UP HILL TO 28.30 TO 28.40 ALL THE WAY TO THE CULVERT END. THIS NEEDS TO RUN FLAT FROM THAT PROPERTY LINE TO THE CULVERT END. LEFT SIDE IS HIGH AS WELL WITH NO REAL SWALE. AREAS ARE PAINTED. IF TOU DO NOT UNDERSTAND WHAT IS REQUIRED PLEASE CALL US AND SET UP A SITE MEET. THE FRONT SWALE IS NOT CORRECT AND NEEDS TO BE ADDRESSED BEFORE MOVING FORWARD. THE CENTER OF THE SWALE AT THE BOTTOM IS TO BE 8 FT FROM THE EDGE OF THE ROAD. PLEASE REFER TO THE SWALE PLAN DETAIL PROVIDE TO YOU WHEN YOR PERMIT WAS ISSUED FOR ALL SWALE REQUIREMENTS. SWALE PLAN DRAWING #300.D. 8/7/2023 - PREVIOUS INSPECTION NOTES 8/7/23= NEED TO READ THE INPECTOR NOTE NEED TO LOWER THE RIGHT SIDE SWALE. MATCH EXISTING GRADE NEED TO REMOVE THE CONCRETE ON THE RIGHT SIDE SWALE 7/31/2023 - PREVIOUS INSPECTION NOTES 07/31/23 UPON WALKING THE PROPERTY SEEMS TO BE SOME LOW SPOTS AND INCONSISTENCY MOVING FORWARD OF DRAINAGE FROM REAR TO FRONT ON RIGHT SIDE PROPERTY LINE. FINAL GRADE NEED TO BE 2" BELOW THE EDGE OF THE ROAD TO ALLOW WATER TO DRAIN OFF OF ROAD INTO SWALE. IT IS TOO HIGH. NEED TO MOVE PORTA POTTY AND CONCRETE CLEANOUT TAILINGS FROM RIGHT SIDE OF SWALE THEY ARE IMPEDEING THE DRAINAGE FLOW.. | |||
| ROW FIELD SURVEY /GRADING CERTIFICATION | 08/09/2023 | Disapproved - NO FEE | FSLADISH |
| Note: 08/09/23 RIGHT SIDE SWALE IS TOO HIGH NEEDS TO BE LOWERED TO MATCH GRADE. IT IS SHOWING 28.20 AT RIGHT PROPERTY LINE THEN IT IS GOING UP HILL TO 28.30 TO 28.40 ALL THE WAY TO THE CULVERT END. THIS NEEDS TO RUN FLAT FROM THAT PROPERTY LINE TO THE CULVERT END. LEFT SIDE IS HIGH AS WELL WITH NO REAL SWALE. AREAS ARE PAINTED. IF TOU DO NOT UNDERSTAND WHAT IS REQUIRED PLEASE CALL US AND SET UP A SITE MEET. THE FRONT SWALE IS NOT CORRECT AND NEEDS TO BE ADDRESSED BEFORE MOVING FORWARD. THE CENTER OF THE SWALE AT THE BOTTOM IS TO BE 8 FT FROM THE EDGE OF THE ROAD. PLEASE REFER TO THE SWALE PLAN DETAIL PROVIDE TO YOU WHEN YOR PERMIT WAS ISSUED FOR ALL SWALE REQUIREMENTS. SWALE PLAN DRAWING #300.D. 8/7/2023 - PREVIOUS INSPECTION NOTES 8/7/23= NEED TO READ THE INPECTOR NOTE NEED TO LOWER THE RIGHT SIDE SWALE. MATCH EXISTING GRADE NEED TO REMOVE THE CONCRETE ON THE RIGHT SIDE SWALE 7/31/2023 - PREVIOUS INSPECTION NOTES 07/31/23 UPON WALKING THE PROPERTY SEEMS TO BE SOME LOW SPOTS AND INCONSISTENCY MOVING FORWARD OF DRAINAGE FROM REAR TO FRONT ON RIGHT SIDE PROPERTY LINE. FINAL GRADE NEED TO BE 2" BELOW THE EDGE OF THE ROAD TO ALLOW WATER TO DRAIN OFF OF ROAD INTO SWALE. IT IS TOO HIGH. NEED TO MOVE PORTA POTTY AND CONCRETE CLEANOUT TAILINGS FROM RIGHT SIDE OF SWALE THEY ARE IMPEDEING THE DRAINAGE FLOW.. | |||
| ROW FIELD SURVEY /GRADING CERTIFICATION | 08/07/2023 | Disapproved -FEE REQUIRED | GBERTOLA |
| Note: 8/7/23= NEED TO READ THE INPECTOR NOTE NEED TO LOWER THE RIGHT SIDE SWALE. MATCH EXISTING GRADE NEED TO REMOVE THE CONCRETE ON THE RIGHT SIDE SWALE 7/31/2023 - PREVIOUS INSPECTION NOTES 07/31/23 UPON WALKING THE PROPERTY SEEMS TO BE SOME LOW SPOTS AND INCONSISTENCY MOVING FORWARD OF DRAINAGE FROM REAR TO FRONT ON RIGHT SIDE PROPERTY LINE. FINAL GRADE NEED TO BE 2" BELOW THE EDGE OF THE ROAD TO ALLOW WATER TO DRAIN OFF OF ROAD INTO SWALE. IT IS TOO HIGH. NEED TO MOVE PORTA POTTY AND CONCRETE CLEANOUT TAILINGS FROM RIGHT SIDE OF SWALE THEY ARE IMPEDEING THE DRAINAGE FLOW.. | |||
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 07/31/2023 | APPROVED | FSLADISH |
| ROW FIELD SURVEY /GRADING CERTIFICATION | 07/31/2023 | Disapproved - NO FEE | FSLADISH |
| Note: 07/31/23 UPON WALKING THE PROPERTY SEEMS TO BE SOME LOW SPOTS AND INCONSISTENCY MOVING FORWARD OF DRAINAGE FROM REAR TO FRONT ON RIGHT SIDE PROPERTY LINE. THE SOD NEEDS TO BE 2" BELOW THE EDGE OF THE ROAD TO ALLOW WATER TO DRAIN OFF OF ROAD INTO SWALE. IT IS TOO HIGH. NEED TO MOVE PORTA POTTY AND CONCRETE CLEANOUT TAILINGS FROM RIGHT SIDE OF SWALE THEY ARE IMPEDEING THE DRAINAGE FLOW.. | |||
| ROW- PRE-APRON (PRE-POUR) | 06/22/2023 | APPROVED | PFLANAGAN |
| Note: IT'S YOUR RESPONSIBILITY TO CHECK THE CULVERT PIPE ELEVATIONS BEFORE POURING CONCRETE FOR THE DRIVEWAY. ALL CONCRETE NEEDS TO BE A MINIMUM OF 3000PSI WITH FIBER OR WITH METAL MESH IN THE POURING AREA. At the time of the inspection all minimum city requirements were met. It is the builders responsibiliy to ensure that nothing changes after this Inspection is approved. -------------------------------------------------------------------------------------------------------------------- 6/21/2023 - PREVIOUS INSPECTION NOTES 6/21/23= FOOTERS HAVE WASHED IN NEED TO BE DUG OUT BOTH SIDES, PICTURE ATTACHED CULVERT PIPE ELEVATION AT TIME OF THE INSPECTION IS OK .PICTURE ATTACHED ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 6/20/2023 - PREVIOUS INSPECTION NOTES 6/20/23= NOTHING HAS BEEN DONE SINCE THE LAST INSPECTION, NEED TO READ THE INPECTOR NOTE. APRON IS SOFT PICTURE ATTACHED. +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 6/16/2023 - PREVIOUS INSPECTION NOTES 06/16/23= FOOTERS HAVE WASHED IN NEED TO BE DUG OUT BOTH SIDES , 300 E RESIDENTIAL CULVERT DETAIL CULVERT PIPE ELEVATION IS GOOD PICTURE ATTACHED | |||
| ROW- PRE-APRON (PRE-POUR) | 06/21/2023 | Disapproved -FEE REQUIRED | GBERTOLA |
| Note: 6/21/23= FOOTERS HAVE WASHED IN NEED TO BE DUG OUT BOTH SIDES, PICTURE ATTACHED CULVERT PIPE ELEVATION AT TIME OF THE INSPECTION IS OK .PICTURE ATTACHED ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 6/20/2023 - PREVIOUS INSPECTION NOTES 6/20/23= NOTHING HAS BEEN DONE SINCE THE LAST INSPECTION, NEED TO READ THE INPECTOR NOTE. APRON IS SOFT PICTURE ATTACHED. +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 6/16/2023 - PREVIOUS INSPECTION NOTES 06/16/23= FOOTERS HAVE WASHED IN NEED TO BE DUG OUT BOTH SIDES , 300 E RESIDENTIAL CULVERT DETAIL CULVERT PIPE ELEVATION IS GOOD PICTURE ATTACHED | |||
| ROW- PRE-APRON (PRE-POUR) | 06/20/2023 | Disapproved -FEE REQUIRED | GBERTOLA |
| Note: 6/20/23= NOTHING HAS BEEN DONE SINCE THE LAST INSPECTION, NEED TO READ THE INPECTOR NOTE. APRON IS SOFT PICTURE ATTACHED. +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 6/16/2023 - PREVIOUS INSPECTION NOTES 06/16/23= FOOTERS HAVE WASHED IN NEED TO BE DUG OUT BOTH SIDES , 300 E RESIDENTIAL CULVERT DETAIL CULVERT PIPE ELEVATION IS GOOD PICTURE ATTACHED | |||
| U-CROSS CONNECTION | 06/16/2023 | APPROVED - AS NOTED | JHARDING |
| Note: No irrigation, no cross connections | |||
| ROW- PRE-APRON (PRE-POUR) | 06/16/2023 | Disapproved -FEE REQUIRED | GBERTOLA |
| Note: 06/16/23= FOOTERS HAVE WASHED IN NEED TO BE DUG OUT BOTH SIDES , 300 E RESIDENTIAL CULVERT DETAIL CULVERT PIPE ELEVATION IS GOOD PICTURE ATTACHED | |||
| ELECTRIC - EARLY POWER | 06/12/2023 | APPROVED - AS NOTED | MKRASKI |
| Note: Emailed FPL @ 2 PM | |||
| ELECTRIC - EARLY POWER | 06/06/2023 | Disapproved - NO FEE | MKRASKI |
| Note: Overhead service wires are required to be sunlight resistant NEC 310.10(d) | |||
| GRAVITY SEWER TEST | 05/31/2023 | APPROVED | MGIBSON |
| U - SEWER TIE IN | 05/31/2023 | APPROVED | MGIBSON |
| PEP TANK INSTALLATION REQUEST | 05/18/2023 | APPROVED | CSTONE |
| INSULATION | 04/19/2023 | APPROVED | RMARTIN |
| Note: 4/17/2023 - PREVIOUS INSPECTION NOTES 4/17/23 1. Door locked need access for inspection 2. Water heater has not be relocated 3. Insulation blown out of garage wall 3/29/2023 - PREVIOUS INSPECTION NOTES Water heater can not be in front of electrical panel min of 3' working space is require for panel NEC 110.26 | |||
| INSULATION | 04/17/2023 | Disapproved -FEE REQUIRED | MKRASKI |
| Note: 4/17/23 1. Door locked need access for inspection 2. Water heater has not be relocated 3. Insulation blown out of garage wall 3/29/2023 - PREVIOUS INSPECTION NOTES Water heater can not be in front of electrical panel min of 3' working space is require for panel NEC 110.26 | |||
| INSULATION | 03/29/2023 | Disapproved - NO FEE | MKRASKI |
| Note: Water heater can not be in front of electrical panel min of 3' working space is require for panel NEC 110.26 | |||
| LATH/BRICK/ WATER BARRIER | 03/29/2023 | APPROVED | MKRASKI |
| LATH/BRICK/ WATER BARRIER | 03/22/2023 | Disapproved - NO FEE | MKRASKI |
| Note: 1. Holes in block need lath 2. Meter main not installed | |||
| INSULATION | 03/22/2023 | Disapproved -FEE REQUIRED | MKRASKI |
| Note: 3/22/23 1. Previous items not repaired 2. Meter main not installed 3/20/2023 - PREVIOUS INSPECTION NOTES 1. Both units, garage wood frame wall needs to be sealed at base and edges 2. B side penitration needs to be fire foamed where door bell wiring for chime is located | |||
| INSULATION | 03/20/2023 | Disapproved - NO FEE | MKRASKI |
| Note: 1. Both units, garage wood frame wall needs to be sealed at base and edges 2. B side penitration needs to be fire foamed where door bell wiring for chime is located | |||
| FIREWALL FINAL | 03/16/2023 | APPROVED | TSTAUFFACHER |
| Note: 3/13/2023 - PREVIOUS INSPECTION NOTES High and low voltage chase's not installed yet, chase's need to be installed, wire pulled, and fire caulked before final | |||
| ALL ROUGH | 03/16/2023 | APPROVED | TSTAUFFACHER |
| FIREWALL FINAL | 03/13/2023 | Disapproved - NO FEE | MKRASKI |
| Note: High and low voltage chase's not installed yet, chase's need to be installed, wire pulled, and fire caulked before final | |||
| WALL SHEATHING | 03/13/2023 | CANCELLED BY INSPECTOR | MKRASKI |
| Note: Inspection not needed | |||
| FIREWALL DRYWALL NAILING | 03/09/2023 | APPROVED | MKRASKI |
| FIREWALL DRYWALL NAILING | 03/08/2023 | CANCELLED BY APPLICANT | WEB |
| FIREWALL DRYWALL NAILING | 03/07/2023 | CANCELLED BY APPLICANT | WEB |
| ROOF VALLEY & METAL | 02/24/2023 | APPROVED | MKRASKI |
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 02/17/2023 | APPROVED | FWILLIS |
| Note: 2/13/2023 - PREVIOUS INSPECTION NOTES 2/13/23 A and B side 1. Interior non load bearing wall not attached to CMU per plans or can not see 2. Truss strap missing on A side front entry marked on print SIDE NOTE: LEFT UNIT HAS 5 RETRO-FITTED TWIST STRAPS. STRAPS ARE WOOD STRAPS, NOT WOOD TO MASONRY STRAPS. Did not check truss engineering 2/9/2023 - PREVIOUS INSPECTION NOTES A side 1. Interior non load bearing wall not attached to CMU per plans or can not see 2. Truss strap missing on A side front entry marked on print 3. Can not see truss straps on back of A side marked on print Stopped inspection on A side re-check all truss strapping, did not look at B side at all | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 02/13/2023 | Disapproved -FEE REQUIRED | MKRASKI |
| Note: 2/13/23 A and B side 1. Interior non load bearing wall not attached to CMU per plans or can not see 2. Truss strap missing on A side front entry marked on print Did not check truss engineering 2/9/2023 - PREVIOUS INSPECTION NOTES A side 1. Interior non load bearing wall not attached to CMU per plans or can not see 2. Truss strap missing on A side front entry marked on print 3. Can not see truss straps on back of A side marked on print Stopped inspection on A side re-check all truss strapping, did not look at B side at all | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 02/09/2023 | Disapproved - NO FEE | MKRASKI |
| Note: A side 1. Interior non load bearing wall not attached to CMU per plans or can not see 2. Truss strap missing on A side front entry marked on print 3. Can not see truss straps on back of A side marked on print Stopped inspection on A side re-check all truss strapping, did not look at B side at all | |||
| TIE BEAM / LINTEL | 01/09/2023 | APPROVED | MKRASKI |
| FOUND SURVEY APPROVED (OFFICE) | 12/07/2022 | APPROVED | TBAKER |
| MONOLITHIC SLAB | 11/21/2022 | APPROVED | MKRASKI |
| Note: | |||
| MONOLITHIC SLAB | 11/17/2022 | Disapproved -FEE REQUIRED | MKRASKI |
| Note: 11/17/22 STILL no compaction paperwork 11/16/2022 - PREVIOUS INSPECTION NOTES No compaction paperwork on site FBC 404.1 Stopped inspection | |||
| MONOLITHIC SLAB | 11/16/2022 | Disapproved - NO FEE | MKRASKI |
| Note: No compaction paperwork on site FBC 404.1 Stopped inspection | |||
| PLUMBING 1ST ROUGH UNDERGROUND | 11/01/2022 | APPROVED | MGIBSON |
| WATER METER INSTALLATION REQUEST | 10/18/2022 | APPROVED | CSTONE |
Review History
| Department | Status | Date In | Date Out |
| MECH | COMPLETE | 08/16/2023 | 08/18/2023 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| MECH | HOLD | 08/14/2023 | 08/15/2023 |
| Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM 1. Energy Calcs need to be signed by the owner/ owner agent below the preparer per R103.1.1.2 FBC Energy Conservation 2020 7Th edition 2. Duct layout needs to be signed by the AC contractor per 107.1 FBC Residential 2020 7th Edition | |||
| BADMIN | INFORMATION | 03/06/2023 | 03/06/2023 |
| Note: Marked INFORMATION By: SCOTT THOMAS - - STHOMAS@PALMCOASTGOV.COM SUBMIT PROD APP SHEET | |||
| BLD | COMPLETE | 03/06/2023 | 03/07/2023 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 02/24/2023 | 02/24/2023 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 02/24/2023 | 03/03/2023 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| ELEC | COMPLETE | 02/24/2023 | 02/24/2023 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 02/15/2023 | 02/16/2023 |
| Note: Released By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM | |||
| BLD | HOLD | 02/09/2023 | 02/15/2023 |
| Note: Held By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM All comments below per the 2020 Florida Building Code PLAN REVIEW COMMENTS: 1. ESR-1338 is if the 1-hour wall designed using the Gypsum Associations design. A revision to the UL Listing is required or revise the Fire Wall Design. | |||
| ENGIN1 | HOLD | 12/07/2022 | 12/07/2022 |
| Note: Held By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 12/07/2022 | 12/07/2022 |
| Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM | |||
| MECH | COMPLETE | 09/16/2022 | 09/16/2022 |
| Note: Released By: CHRIS PISCITELLI - (386)986-3782 - CPISCITELLI@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 09/16/2022 | 09/19/2022 |
| Note: Released By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM | |||
| BLD | HOLD | 09/09/2022 | 09/13/2022 |
| Note: Held By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM PLAN REVIEW COMMENTS: Repeat Comments 1. Product Approval Specification Sheet; a. Product Approval for the proposed underlayment on the Roofing Worksheet does not match the Product Approval Sheet. Revise to reflect the correct underlayment to be used. Per F.S. 471.025 and F.A.C. 61 G15-23.005. | |||
| CUSVC | COMPLETE | 09/09/2022 | 09/13/2022 |
| Note: Released By: HALEIGH HAND - - | |||
| ELEC | COMPLETE | 09/09/2022 | 09/09/2022 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 09/09/2022 | 09/09/2022 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| LOCATE | COMPLETE | 09/09/2022 | 09/14/2022 |
| Note: Released By: CANDACE STONE - - CSTONE@PALMCOASTGOV.COM | |||
| MECH | HOLD | 09/09/2022 | 09/09/2022 |
| Note: Held By: CHRIS PISCITELLI - (386)986-3782 - CPISCITELLI@PALMCOASTGOV.COM 1. Energy Calcs need to be signed by the builder per 107.1 FBC Residential 2020 7th edition 2. Plans show common wall CMU. Energy calcs say Frame. Revise to match | |||
| SW1 | COMPLETE | 09/09/2022 | 09/16/2022 |
| Note: Released By: ROBERT GROSS - (386)986-4769 - RGROSS@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 09/09/2022 | 09/15/2022 |
| Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM Landscape plan: missing please provide a plan | |||
| SWALE | COMPLETE | 09/09/2022 | 01/05/2023 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| PLAN REVIEW - REVISION | ¤32.50 | 08/29/2023 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 08/29/2023 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 08/29/2023 |
| SW ENG REINSPECTION 20 | ¤20.00 | 08/09/2023 |
| SW ENG REINSPECTION 30 | ¤30.00 | 06/21/2023 |
| SW ENG REINSPECTION 30 | ¤30.00 | 06/20/2023 |
| SW ENG REINSPECTION 30 | ¤30.00 | 06/20/2023 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 04/19/2023 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 03/22/2023 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 02/23/2023 |
| CONTRACTOR CHANGE | ¤20.00 | 02/08/2023 |
| CONTRACTOR CHANGE | ¤20.00 | 02/08/2023 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 12/07/2022 |
| IMPACT FEE SCHOOL | ¤3,700.00 | 10/10/2022 |
| IMPACT FEE SCHOOL | ¤7,200.00 | 09/26/2022 |
| IMPACT FEE TRANSPORTATION | ¤2,738.00 | 09/26/2022 |
| WATER -IRRIGATION INSPECTION | ¤50.00 | 09/26/2022 |
| 3% PARKS IMPACT FEE CREDIT | (¤87.31) | 09/26/2022 |
| SURCHARGE FS 533.721 | ¤4.00 | 09/26/2022 |
| SURCHARGE - FS 468.631 | ¤6.00 | 09/26/2022 |
| SW ENG - FOUNDATION SURVEY | ¤20.00 | 09/26/2022 |
| SW ENG INSPECTION 80 | ¤80.00 | 09/26/2022 |
| SW ENG PRE APRON | ¤30.00 | 09/26/2022 |
| SW ENG - REVIEW 20 | ¤20.00 | 09/26/2022 |
| SW ENG RES REVIEW 200 | ¤200.00 | 09/26/2022 |
| 3% TRANS IMPACT FEE CREDIT | (¤82.14) | 09/26/2022 |
| SEWER CREDIT | (¤2,016.00) | 09/26/2022 |
| SEWER INSPECTION | ¤25.00 | 09/26/2022 |
| SEWER CAPITAL FACILITY | ¤9,879.52 | 09/26/2022 |
| WATER CAPITAL FACILITY FEE | ¤7,253.00 | 09/26/2022 |
| SITE PLAN 30 | ¤30.00 | 09/26/2022 |
| WATER- TURN ON | ¤50.00 | 09/26/2022 |
| ADJUSTMENT 50% | (¤632.75) | 09/26/2022 |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | 09/26/2022 |
| INSPECTION - RESIDENTIAL | ¤962.50 | 09/26/2022 |
| PLAN REVIEW - RESIDENTIAL | ¤273.00 | 09/26/2022 |
| 3% FIRE IMPACT FEE CREDIT | (¤23.32) | 09/26/2022 |
| IMPACT FEE FIRE | ¤777.30 | 09/26/2022 |
| IMPACT FEE PARKS | ¤2,910.26 | 09/26/2022 |
| CONNECTION FEES | ¤2,155.76 | 09/26/2022 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤35,975.32 |