Permit #2022090764

Permit Details

Status: COED

Parcel Id: 07-11-31-7033-00230-0120
Block: 00230
Subdivision: 2184 - SECTION 33-ROYAL PALMS
Job Phone: 941-677-2599
Location Address: 30 REYBURY LN
Type: RF - REROOF
Issue Date: 09/26/2022
NOC: RECORDED
Applicant name: SALVATORE RINALDI
Owner: MEJIA CECILIA M & GIACOMO RAIMONDI W&H JTWROS

Address

30 REYBURY LANE

PALM COAST, FL 32164

Lot: 0120
Contracted Stated Job Value: ¤18,000.00
Job Description: re-roof
Type: CN

Contractor

FORTUNE ROOFING LLC
Status Location Address State License Number
CANCEL

1370 US 1 UNIT 204

ORMOND BEACH, FL 32174

CCC019008 (Exp: 08/31/2024)

Inspection History

Type Request Date Result Inspector
ROOF FINAL 10/24/2022 FINAL APPROVED JWALKER
Note: 10/20/2022 - PREVIOUS INSPECTION NOTES 10/14/2022 - PREVIOUS INSPECTION NOTES Wire screen not removed from dyer vent termination. Joiner seam at electrical mast boot flashing is to have sealant applied per manufactures specs. Materials, ridge vent, box of fasteners, roll roofing, and shingles are laying in the driveway, 10/18/22 Materials removed. Other listed items have not been corrected. 10/20/22 Screen was removed from dryer vent however the damper was pushed in. Damper needs open outward to allow lint to escape. The joiner seam at the electrical boot mast has still not had sealant applied. There are two nails below the shingle lap right side of the lower garage roof next to the hip.
ROOF FINAL 10/20/2022 Disapproved -FEE REQUIRED JWALKER
Note: 10/14/2022 - PREVIOUS INSPECTION NOTES Wire screen not removed from dyer vent termination. Joiner seam at electrical mast boot flashing is to have sealant applied per manufactures specs. Materials, ridge vent, box of fasteners, roll roofing, and shingles are laying in the driveway, 10/18/22 Materials removed. Other listed items have not been corrected. 10/20/22 Screen was removed from dryer vent however the damper was pushed in. Damper needs open outward to allow lint to escape. The joiner seam at the electrical boot mast has still not had sealant applied. There are two nails below the shingle lap right side of the lower garage roof next to the hip.
ROOF FINAL 10/18/2022 Disapproved -FEE REQUIRED JWALKER
Note: 10/14/2022 - PREVIOUS INSPECTION NOTES Wire screen not removed from dyer vent termination. Joiner seam at electrical mast boot flashing is to have sealant applied per manufactures specs. Materials, ridge vent, box of fasteners, roll roofing, and shingles are laying in the driveway, 10/18/22 Materials removed. Other listed items have not been corrected.
ROOF FINAL 10/14/2022 Disapproved -FEE REQUIRED JWALKER
Note: Wire screen not removed from dyer vent termination. Joiner seam at electrical mast boot flashing is to have sealant applied per manufactures specs. Materials, ridge vent, box of fasteners, roll roofing, and shingles are laying in the driveway,
ROOF IN PROGRESS- MIDROOF 10/11/2022 APPROVED JWALKER
ROOF AFFIDAVIT 10/10/2022 APPROVED MDEFREITAS

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
REINSPECTION RESIDENTIAL ¤40.00 10/20/2022
REINSPECTION RESIDENTIAL ¤40.00 10/18/2022
REINSPECTION RESIDENTIAL ¤40.00 10/17/2022
ADJUSTMENT 50% (¤45.00) 09/26/2022
ADMINISTRATIVE RESIDENTIAL ¤30.00 09/26/2022
INSPECTION - RESIDENTIAL ¤60.00 09/26/2022
SURCHARGE FS 533.721 ¤2.00 09/26/2022
SURCHARGE - FS 468.631 ¤2.00 09/26/2022
Fees Total Due: ¤0.00 Total Paid: ¤169.00