Permit #2022091239
Permit Details
Status: COED
| Parcel Id: 07-11-31-7035-00930-0150 |
| CONDITIONED SPACE: 1788 sqft |
| GARAGE: 578 sqft |
| OPENED PORCH (WITH ROOF) : 69 sqft |
| OPENED PORCH (WITH ROOF) : 32 sqft |
| Total Square Footage: 2467 sqft |
| Block: 00930 |
| Subdivision: 2172 - SECTION 35-BELLE TERRE |
| Job Phone: 386-248-0033 |
| Location Address: 36 BUFFALO BILL DR |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 05/11/2023 |
| NOC: RECORDED |
| Applicant name: JEFFREY T WISE |
| Owner: 3 S HOUSING LLC |
|
Address 226 N NOVA RD #318 ORMOND BEACH, FL 32174 |
| Lot: 0150 |
| Contracted Stated Job Value: ¤278,000.00 |
| Job Description: SINGLE FAMILY HOME |
| Type: CN |
Contractor
WISE BUILDERS LLC
| Status | Location Address | State License Number | Phone |
| ACTIVE |
120 CARSWELL AVE HOLLY HILL, FL 32117 |
CGC055237 (Exp: 08/31/2026) | 386-248-0033 |
Sub Contractors
JAMES R DOOLEY
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
1550 GARDEN AVENUE HOLLY HILL, FL 32117 |
EC13005817 (Exp: 08/31/2026) | 386-672-4433 | 386-672-9793 |
KEVIN HENRY BEHRENS
| Status | Location Address | State License Number | Phone | Fax |
| INACTIVE |
1200 SOUTH NOVA ROAD DAYTONA BEACH, FL 32114 |
CAC054733 (Exp: 08/31/2026) | (386)761-7751 | (386) 258-0058 |
RUSSELL J CARTER
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
PO BOX 302 DELAND, FL 32721 |
CFC1425938 (Exp: 08/31/2026) | 386-736-4220 | 386-736-4219 |
Inspection History
| Type | Request Date | Result | Inspector |
| BLD - BUILDING FINAL | 04/01/2024 | FINAL APPROVED | MKRASKI |
| Note: 3/28/2024 - PREVIOUS INSPECTION NOTES 3/28/24- 1. Please Identify switch by garage to house door and Location height should be no more then 6'7" off the floor to the center of the control. Per NEC 404.8 Accessibility and Grouping. (A) Location. 2. Please seal Plenum ceiling penetration at AHU.R402.4, 3. Please seal or cap dryer duct (unless dryer is installed). M1502.4.7 Exhaust duct required.....Where the clothes dryer is not installed at the time of occupancy the exhaust duct shall be capped or plugged in the space in which it originates.... 4. Hot water discharge needs protected by landscape (mulch) from damage.FBC P305. Protection of components of plumbing 5. please seal wall penetration at doorbell transformer.R402.4, 6. Please seal wall penetration at main water supply shut off.R402.4, 7. Please seal ceiling Penetrations at garage door opener cat 5.R402.4, | |||
| BLD - BUILDING FINAL | 03/28/2024 | Disapproved - NO FEE | JSTEWART |
| Note: 3/28/24- 1. Please Identify switch by garage to house door and Location height should be no more then 6'7" off the floor to the center of the control. Per NEC 404.8 Accessibility and Grouping. (A) Location. 2. Please seal Plenum ceiling penetration at AHU.R402.4, 3. Please seal or cap dryer duct (unless dryer is installed). M1502.4.7 Exhaust duct required.....Where the clothes dryer is not installed at the time of occupancy the exhaust duct shall be capped or plugged in the space in which it originates.... 4. Hot water discharge needs protected by landscape (mulch) from damage.FBC P305. Protection of components of plumbing 5. please seal wall penetration at doorbell transformer.R402.4, 6. Please seal wall penetration at main water supply shut off.R402.4, 7. Please seal ceiling Penetrations at garage door opener cat 5.R402.4, | |||
| ROW - FINAL APRON (AFTER POUR) | 03/27/2024 | APPROVED - AS NOTED | FSLADISH |
| Note: 3/27/24 PIPE IS GOOD. CUTS MADE. CULVERT CLEAR. HOT PATCH COMPLETED AT THE TIME OF THIS INSPECTION. At the time of the inspection all minimum city requirements were met. It is the builders responsibiliy to ensure that nothing changes after this Inspection is approved. ________________________________________________________________________________________________________________________ Inspector Notes from Inspection 9465 3/26/24 PER MY CONVERSATION WITH GABE BERTOLA, WE ARE GOING TO PASS TIS FIELD SURVEY AS NOTED. YOU MAY BE REQUIRED TO MAKE ADDITIONAL CORRECTIONS UPON SUBSEQUENT INSPECTIONS DEPENDING ON FIELD CONDITIONS AT THAT TIME. 3/20/2024 - PREVIOUS INSPECTION NOTES 3/20/24 GOING TO MEET WITH JEFF TOMORROW 3/21/24 WITH REGARD TO 36 BUFFALO BILL DR. | |||
| ROW - STORMWATER FINAL | 03/27/2024 | APPROVED - AS NOTED | FSLADISH |
| Note: 3/27/24 At the time of the inspection all minimum city requirements were met. It is the builders responsibiliy to ensure that nothing changes after this Inspection is approved. ________________________________________________________________________________________________________________________ Inspector Notes from Inspection 9465 3/26/24 PER MY CONVERSATION WITH GABE BERTOLA, WE ARE GOING TO PASS TIS FIELD SURVEY AS NOTED. YOU MAY BE REQUIRED TO MAKE ADDITIONAL CORRECTIONS UPON SUBSEQUENT INSPECTIONS DEPENDING ON FIELD CONDITIONS AT THAT TIME. 3/20/2024 - PREVIOUS INSPECTION NOTES 3/20/24 GOING TO MEET WITH JEFF TOMORROW 3/21/24 WITH REGARD TO 36 BUFFALO BILL DR. | |||
| U -UTILITY RESIDENTIAL FINAL | 03/27/2024 | FINAL APPROVED | DHANEY |
| Note: Inspector Notes from Inspection 9035 No irrigation, no cross connections. | |||
| ROW FIELD SURVEY /GRADING CERTIFICATION | 03/26/2024 | APPROVED - AS NOTED | FSLADISH |
| Note: 3/26/24 PER MY CONVERSATION WITH GABE BERTOLA, WE ARE GOING TO PASS TIS FIELD SURVEY AS NOTED. YOU MAY BE REQUIRED TO MAKE ADDITIONAL CORRECTIONS UPON SUBSEQUENT INSPECTIONS DEPENDING ON FIELD CONDITIONS AT THAT TIME. 3/20/2024 - PREVIOUS INSPECTION NOTES 3/20/24 GOING TO MEET WITH JEFF TOMORROW 3/21/24 WITH REGARD TO 36 BUFFALO BILL DR. | |||
| ROW FIELD SURVEY /GRADING CERTIFICATION | 03/20/2024 | CANCELLED BY APPLICANT | FSLADISH |
| Note: 3/20/24 GOING TO MEET WITH JEFF TOMORROW 3/21/24 WITH REGARD TO 36 BUFFALO BILL DR. | |||
| U-CROSS CONNECTION | 03/20/2024 | APPROVED - AS NOTED | JHARDING |
| Note: No irrigation, no cross connections. | |||
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 03/19/2024 | APPROVED | FSLADISH |
| Note: 3/7/2024 - PREVIOUS INSPECTION NOTES 3/7/24 THE CULVERT PIPE ELEVATION IS OUT OF TOLERANCE TO SWALE PLAN. Culvert Out of Tolerence Swale Plan #1 Swale Plan #1. The driveway culvert inverts are to be installed within 0.1' (+/-) of the elevations indicated on the swale plan (unless otherwise approved by the City StormwaterEngineer). The finished swale elevation is with sod in place YOUR ELEVATION SHOTS ALOG THE RIGHT SIDE PROPERTY LINE DO NOT SHOW POSITIVE REAR TO FRONT SWALE DRAINAGE. Rear Yard Drainage Sec 300.01(4,5,6) Sec 300.01(4,5,6) The tolerance along side lot lines is no more than 20 feet flat, with positive fall on each side.Positive fall is considered to be 0.10 feet in 20 feet.The minimum fall from the rear property line to the front is 0.50 feet. Rear Yard Drainage Sec 300.01(4,5,6) Sec 300.01(4,5,6) The tolerance along side lot lines is no more than 20 feet flat, with positive fall on each side.Positive fall is considered to be 0.10 feet in 20 feet.The minimum fall from the rear property line to the front is 0.50 feet Rear yard will be drained Section 300.01 Section 300.01.Identify how the rear yard will be drained. The rear yard is required to drain to the front yard swale. __________________________________________________________________________________________________________________________ Inspector Notes from Inspection 9270 ** 01/18/24 READY TO POUR ** At the time of the inspection all minimum city requirements were met. It is the builders responsibiliy to ensure that nothing changes after this Inspection is approved. This includes but is not limited to, the Culvert Pipe Elevation from the time of the inspection approval to the concrete pour. ** Sec.900.04C Residential driveways shall be constructed using material with a minimum of three thousand pounds (3,000 Ibs.) per square inch with Fiber or wire mesh. __________________________________________________________________________________________________________________ 1/16/2024 - PREVIOUS INSPECTION NOTES ** 01/16/24 SITE TOO WET _________________________________________________________________________________________________________________________ 1/12/2024 - PREVIOUS INSPECTION NOTES TOO MUCH WATER IN THE POUR AREA. WAY TOO SOFT TO POUR. | |||
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 03/07/2024 | Disapproved - NO FEE | FSLADISH |
| Note: 3/7/24 THE CULVERT PIPE ELEVATION IS OUT OF TOLERANCE TO SWALE PLAN. Culvert Out of Tolerence Swale Plan #1 Swale Plan #1. The driveway culvert inverts are to be installed within 0.1' (+/-) of the elevations indicated on the swale plan (unless otherwise approved by the City StormwaterEngineer). The finished swale elevation is with sod in place YOUR ELEVATION SHOTS ALOG THE RIGHT SIDE PROPERTY LINE DO NOT SHOW POSITIVE REAR TO FRONT SWALE DRAINAGE. Rear Yard Drainage Sec 300.01(4,5,6) Sec 300.01(4,5,6) The tolerance along side lot lines is no more than 20 feet flat, with positive fall on each side.Positive fall is considered to be 0.10 feet in 20 feet.The minimum fall from the rear property line to the front is 0.50 feet. Rear Yard Drainage Sec 300.01(4,5,6) Sec 300.01(4,5,6) The tolerance along side lot lines is no more than 20 feet flat, with positive fall on each side.Positive fall is considered to be 0.10 feet in 20 feet.The minimum fall from the rear property line to the front is 0.50 feet Rear yard will be drained Section 300.01 Section 300.01.Identify how the rear yard will be drained. The rear yard is required to drain to the front yard swale. __________________________________________________________________________________________________________________________ Inspector Notes from Inspection 9270 ** 01/18/24 READY TO POUR ** At the time of the inspection all minimum city requirements were met. It is the builders responsibiliy to ensure that nothing changes after this Inspection is approved. This includes but is not limited to, the Culvert Pipe Elevation from the time of the inspection approval to the concrete pour. ** Sec.900.04C Residential driveways shall be constructed using material with a minimum of three thousand pounds (3,000 Ibs.) per square inch with Fiber or wire mesh. __________________________________________________________________________________________________________________ 1/16/2024 - PREVIOUS INSPECTION NOTES ** 01/16/24 SITE TOO WET _________________________________________________________________________________________________________________________ 1/12/2024 - PREVIOUS INSPECTION NOTES TOO MUCH WATER IN THE POUR AREA. WAY TOO SOFT TO POUR. | |||
| U - SEWER TIE IN | 02/20/2024 | APPROVED | MGIBSON |
| Note: Inspector Notes from Inspection 2075 U-SEWER AND OR SEWER TIE IN NEEDS TO BE SCHEDUALED ALONG WITH GRAVITY SEWER BOTH ARE APPROVED OK TOCOVER UP. SPOKE TO JEFF WISE HE WILL SCHEDUAL IT FOR 2/2O/24 | |||
| GRAVITY SEWER TEST | 02/16/2024 | APPROVED - AS NOTED | MGIBSON |
| Note: U-SEWER AND OR SEWER TIE IN NEEDS TO BE SCHEDUALED ALONG WITH GRAVITY SEWER BOTH ARE APPROVED OK TOCOVER UP. SPOKE TO JEFF WISE HE WILL SCHEDUAL IT FOR 2/2O/24 | |||
| ELECTRIC - EARLY POWER | 02/06/2024 | APPROVED - AS NOTED | JSTEWART |
| Note: 2/6/24- Please install chase above Garage breaker panel, to Protect Wireing from damage Before final. Inspector Notes from Inspection 2170 8/11/23-Authorize release of email to FPL @ 12:21p | |||
| ROW- PRE-APRON (PRE-POUR) | 01/18/2024 | APPROVED - AS NOTED | EMADISON |
| Note: ** 01/18/24 READY TO POUR ** At the time of the inspection all minimum city requirements were met. It is the builders responsibiliy to ensure that nothing changes after this Inspection is approved. This includes but is not limited to, the Culvert Pipe Elevation from the time of the inspection approval to the concrete pour. ** Sec.900.04C Residential driveways shall be constructed using material with a minimum of three thousand pounds (3,000 Ibs.) per square inch with Fiber or wire mesh. __________________________________________________________________________________________________________________ 1/16/2024 - PREVIOUS INSPECTION NOTES ** 01/16/24 SITE TOO WET _________________________________________________________________________________________________________________________ 1/12/2024 - PREVIOUS INSPECTION NOTES TOO MUCH WATER IN THE POUR AREA. WAY TOO SOFT TO POUR. | |||
| ROW- PRE-APRON (PRE-POUR) | 01/16/2024 | CANCELLED BY APPLICANT | EMADISON |
| Note: ** 01/16/24 SITE TOO WET _________________________________________________________________________________________________________________________ 1/12/2024 - PREVIOUS INSPECTION NOTES TOO MUCH WATER IN THE POUR AREA. WAY TOO SOFT TO POUR. | |||
| ROW- PRE-APRON (PRE-POUR) | 01/12/2024 | Disapproved - NO FEE | GBERTOLA |
| Note: TOO MUCH WATER IN THE POUR AREA. WAY TOO SOFT TO POUR. | |||
| LATH/BRICK/ WATER BARRIER | 01/03/2024 | APPROVED | AGAETANO |
| PEP TANK INSTALLATION REQUEST | 01/02/2024 | APPROVED | TCHURCHILL |
| INSULATION | 12/28/2023 | CANCELLED BY APPLICANT | WEB |
| Note: 12/27/2023 - PREVIOUS INSPECTION NOTES 12/27/23 - FIRESTOP ELECTRICAL PANEL IN GARAGE, LAUNDRY ROOM AND CHECK THROUGHOUT. REMOVE UNAPPROVED SEALANT AND REPLACE WITH APPROVED FIRESTOPPING, BATHROOM VENT. Inspector Notes from Inspection 2420 1. Right side of the building master bed closet missing 4" HVAC supply duct. 2. Nail plate at the dryer duct is to extend 2" below the bottom of the top plate. M-1308.2.1 Check for corrections at Insulation inspection. | |||
| INSULATION | 12/28/2023 | APPROVED | JSTEWART |
| Note: New inspection due to canceled inspection 12/27/2023 - PREVIOUS INSPECTION NOTES 12/27/23 - FIRESTOP ELECTRICAL PANEL IN GARAGE, LAUNDRY ROOM AND CHECK THROUGHOUT. REMOVE UNAPPROVED SEALANT AND REPLACE WITH APPROVED FIRESTOPPING, BATHROOM VENT. Inspector Notes from Inspection 2420 1. Right side of the building master bed closet missing 4" HVAC supply duct. 2. Nail plate at the dryer duct is to extend 2" below the bottom of the top plate. M-1308.2.1 Check for corrections at Insulation inspection. | |||
| INSULATION | 12/27/2023 | Disapproved -FEE REQUIRED | FWILLIS |
| Note: 12/27/23 - FIRESTOP ELECTRICAL PANEL IN GARAGE, LAUNDRY ROOM AND CHECK THROUGHOUT. REMOVE UNAPPROVED SEALANT AND REPLACE WITH APPROVED FIRESTOPPING, BATHROOM VENT. Inspector Notes from Inspection 2420 1. Right side of the building master bed closet missing 4" HVAC supply duct. 2. Nail plate at the dryer duct is to extend 2" below the bottom of the top plate. M-1308.2.1 Check for corrections at Insulation inspection. | |||
| ALL ROUGH | 12/14/2023 | APPROVED - AS NOTED | JWALKER |
| Note: 1. Right side of the building master bed closet missing 4" HVAC supply duct. 2. Nail plate at the dryer duct is to extend 2" below the bottom of the top plate. M-1308.2.1 Check for corrections at Insulation inspection. | |||
| WALL SHEATHING | 12/13/2023 | APPROVED | JSTEWART |
| ROOF VALLEY & METAL | 12/13/2023 | APPROVED | JSTEWART |
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 12/12/2023 | APPROVED | JSTEWART |
| Note: 12/8/2023 - PREVIOUS INSPECTION NOTES 12/8/23- No approved plans on site. DOCUMENTS MUST BE APPROVED AND KEPT ON SITE 107.3,1. AND SHALL BE OPEN TO INSPECTION BY THE BUILDING OFFICIAL | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 12/08/2023 | Disapproved - NO FEE | JSTEWART |
| Note: 12/8/23- No approved plans on site. DOCUMENTS MUST BE APPROVED AND KEPT ON SITE 107.3,1. AND SHALL BE OPEN TO INSPECTION BY THE BUILDING OFFICIAL | |||
| FOUND SURVEY APPROVED (OFFICE) | 12/07/2023 | APPROVED | JGONZALEZ |
| TIE BEAM / LINTEL | 09/28/2023 | APPROVED | FWILLIS |
| Note: 9/27/2023 - PREVIOUS INSPECTION NOTES 9/27/2023- Front entry columns need to be installed as shown on plans pg. S1 detail A-Front beam detail. detail shows 2 Reinforcement bars within the column, and Bond beams at the top with Lateral ties . 2 lateral ties within the first 5" of top, if Bond beam is not used per.. R606.12.2.3.2. | |||
| TIE BEAM / LINTEL | 09/27/2023 | Disapproved - NO FEE | JSTEWART |
| Note: 9/27/2023- Front entry columns need to be installed as shown on plans pg. S1 detail A-Front beam detail. detail shows 2 Reinforcement bars within the column, and Bond beams at the top with Lateral ties . 2 lateral ties within the first 5" of top, if Bond beam is not used per.. R606.12.2.3.2. | |||
| MONOLITHIC SLAB | 09/20/2023 | CANCELLED BY APPLICANT | WEB |
| MONOLITHIC SLAB | 09/20/2023 | APPROVED | FWILLIS |
| PLUMBING 1ST ROUGH UNDERGROUND | 09/15/2023 | APPROVED | MGIBSON |
| WATER METER INSTALLATION REQUEST | 08/17/2023 | APPROVED | CBOWERMASTER |
| ELECTRIC TEMP POLE | 08/11/2023 | APPROVED - AS NOTED | JSTEWART |
| Note: 8/11/23-Authorize release of email to FPL @ 12:21p |
Review History
| Department | Status | Date In | Date Out |
| BLD | COMPLETE | 12/22/2023 | 12/22/2023 |
| Note: Released By: PATRICK BUCKLEY - (386)986-3786 - PBUCKLEY@PALMCOASTGOV.COM | |||
| BLD | HOLD | 12/19/2023 | 12/22/2023 |
| Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. Needs to be digitally signed and sealed | |||
| BLD | HOLD | 12/12/2023 | 12/15/2023 |
| Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. Needs to be digitally signed and sealed | |||
| ZON | COMPLETE | 12/07/2023 | 12/07/2023 |
| Note: Released By: JACQUELINE GONZALEZ - (386)986-3751 - JGONZALEZ@PALMCOASTGOV.COM Development Order for Adminstrative Deviation was approved 12/6/2023jg | |||
| ENGIN1 | COMPLETE | 11/08/2023 | 11/08/2023 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| ZON | HOLD | 11/08/2023 | 11/08/2023 |
| Note: Held By: MICHELLE RAMOS - (386)986-3780 - MRAMOS@PALMCOASTGOV.COM The front setback on foundation plan doesn't meet the front setback. | |||
| MECH | COMPLETE | 11/07/2022 | 11/07/2022 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| ELEC | COMPLETE | 11/07/2022 | 11/08/2022 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| MECH | HOLD | 11/02/2022 | 11/02/2022 |
| Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM 1. Duct layout shows supply in garrage and return in wall in garage. Cannot have ductwork off house system. Revise duct layout. 2. Duct layout needs to be signed by AC contractor or signed and sealed by Engineer of record | |||
| ZON | HOLD | 10/26/2022 | 10/26/2022 |
| Note: Held By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM Floor plan calculations have a door stoop. No other documents show a door stoop. Please remove in calculations or show location on all plans. Site plan/Survey must show a front entry walkway with material and width. Site plan/survey must show driveway width. | |||
| ZON | COMPLETE | 10/26/2022 | 10/26/2022 |
| Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM | |||
| MECH | HOLD | 10/26/2022 | 10/26/2022 |
| Note: Held By: CHRIS PISCITELLI - (386)986-3782 - CPISCITELLI@PALMCOASTGOV.COM 1. Duct layout shows supply in garrage and return in wall in garage. Cannot have ductwork off house system. Revise duct layout. 2. Duct layout needs to be signed by AC contractor or signed and sealed by Engineer of record | |||
| BLD | COMPLETE | 10/26/2022 | 11/02/2022 |
| Note: Released By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 10/26/2022 | 10/26/2022 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| SW1 | COMPLETE | 10/26/2022 | 11/02/2022 |
| Note: Released By: GABRIEL BERTOLA - (386)986-7660 - GBERTOLA@PALMCOASTGOV.COM | |||
| BLD | HOLD | 09/28/2022 | 10/03/2022 |
| Note: Held By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM All comments below per the 2020 Florida Building Code REVIEW COMMENTS: 1. Provide Detail F-5/S-1 for Garage slab. | |||
| CUSVC | COMPLETE | 09/28/2022 | 09/29/2022 |
| Note: Released By: HALEIGH HAND - - | |||
| ELEC | HOLD | 09/28/2022 | 09/28/2022 |
| Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. Need at least two outlets in the garage. NEC 2017 210.52 (G)(1) 2. Need outlet on the front of the house. NEC 2017 210.52 (E)(1) | |||
| ENGIN1 | COMPLETE | 09/28/2022 | 09/28/2022 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| LOCATE | COMPLETE | 09/28/2022 | 10/06/2022 |
| Note: Released By: CANDACE STONE - - CSTONE@PALMCOASTGOV.COM | |||
| MECH | HOLD | 09/28/2022 | 10/04/2022 |
| Note: Held By: CHRIS PISCITELLI - (386)986-3782 - CPISCITELLI@PALMCOASTGOV.COM 1. R403.7.1.2.1 FBC Energy Conservation 2020 7TH Edition- Chosen equipment exceeds the maximum of 1.15 times the load calculated. 2. Provide Duct layout signed by the AC contractor | |||
| SW1 | COMPLETE | 09/28/2022 | 10/06/2022 |
| Note: Released By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM NEED TO PUT THE BERM FERTHER BACK TO THE PROPERTY LINE | |||
| ZON | HOLD | 09/28/2022 | 09/28/2022 |
| Note: Held By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM Floor plan calculations have a door stoop. No other documents show a door stoop. Please remove in calculations or show location on all plans. Site plan/Survey must show a front entry walkway with material and width. Site plan/survey must show driveway width. | |||
| SWALE | COMPLETE | 09/28/2022 | 01/31/2023 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| REINSPECTION RESIDENTIAL | ¤40.00 | 12/27/2023 |
| CONNECTION FEES | ¤1,166.26 | 05/11/2023 |
| 3% FIRE IMPACT FEE CREDIT | (¤11.66) | 05/11/2023 |
| IMPACT FEE FIRE | ¤388.65 | 05/11/2023 |
| IMPACT FEE PARKS | ¤1,455.13 | 05/11/2023 |
| IMPACT FEE SCHOOL | ¤5,450.00 | 05/11/2023 |
| IMPACT FEE TRANSPORTATION | ¤1,764.00 | 05/11/2023 |
| WATER -IRRIGATION INSPECTION | ¤25.00 | 05/11/2023 |
| 3% PARKS IMPACT FEE CREDIT | (¤43.65) | 05/11/2023 |
| SURCHARGE FS 533.721 | ¤3.27 | 05/11/2023 |
| SURCHARGE - FS 468.631 | ¤4.91 | 05/11/2023 |
| SW ENG - FOUNDATION SURVEY | ¤20.00 | 05/11/2023 |
| SW ENG INSPECTION 80 | ¤80.00 | 05/11/2023 |
| SW ENG PRE APRON | ¤30.00 | 05/11/2023 |
| SW ENG - REVIEW 20 | ¤20.00 | 05/11/2023 |
| SW ENG RES REVIEW 200 | ¤200.00 | 05/11/2023 |
| 3% TRANS IMPACT FEE CREDIT | (¤52.92) | 05/11/2023 |
| SEWER CREDIT | (¤850.00) | 05/11/2023 |
| SEWER INSPECTION | ¤25.00 | 05/11/2023 |
| SEWER CAPITAL FACILITY | ¤5,344.82 | 05/11/2023 |
| WATER CAPITAL FACILITY FEE | ¤3,923.88 | 05/11/2023 |
| SITE PLAN 30 | ¤30.00 | 05/11/2023 |
| WATER- TURN ON | ¤25.00 | 05/11/2023 |
| ADJUSTMENT 50% | (¤505.67) | 05/11/2023 |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | 05/11/2023 |
| INSPECTION - RESIDENTIAL | ¤764.50 | 05/11/2023 |
| PLAN REVIEW - RESIDENTIAL | ¤216.84 | 05/11/2023 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤19,543.36 |