I want to search for...

Permit #2022091239

Permit Details

Status: COED

Parcel Id: 07-11-31-7035-00930-0150
CONDITIONED SPACE: 1788 sqft
GARAGE: 578 sqft
OPENED PORCH (WITH ROOF) : 69 sqft
OPENED PORCH (WITH ROOF) : 32 sqft
Total Square Footage: 2467 sqft
Block: 00930
Subdivision: 2172 - SECTION 35-BELLE TERRE
Job Phone: 386-248-0033
Location Address: 36 BUFFALO BILL DR
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 05/11/2023
NOC: RECORDED
Applicant name: JEFFREY T WISE
Owner: 3 S HOUSING LLC

Address

226 N NOVA RD #318

ORMOND BEACH, FL 32174

Lot: 0150
Contracted Stated Job Value: ¤278,000.00
Job Description: SINGLE FAMILY HOME
Type: CN

Contractor

WISE BUILDERS LLC
Status Location Address State License Number Phone
ACTIVE

120 CARSWELL AVE

HOLLY HILL, FL 32117

CGC055237 (Exp: 08/31/2026) 386-248-0033

Sub Contractors

JAMES R DOOLEY
Status Location Address State License Number Phone Fax
ACTIVE

1550 GARDEN AVENUE

HOLLY HILL, FL 32117

EC13005817 (Exp: 08/31/2026) 386-672-4433 386-672-9793
KEVIN HENRY BEHRENS
Status Location Address State License Number Phone Fax
INACTIVE

1200 SOUTH NOVA ROAD

DAYTONA BEACH, FL 32114

CAC054733 (Exp: 08/31/2026) (386)761-7751 (386) 258-0058
RUSSELL J CARTER
Status Location Address State License Number Phone Fax
ACTIVE

PO BOX 302

DELAND, FL 32721

CFC1425938 (Exp: 08/31/2026) 386-736-4220 386-736-4219

Inspection History

Type Request Date Result Inspector
BLD - BUILDING FINAL 04/01/2024 FINAL APPROVED MKRASKI
Note: 3/28/2024 - PREVIOUS INSPECTION NOTES 3/28/24- 1. Please Identify switch by garage to house door and Location height should be no more then 6'7" off the floor to the center of the control. Per NEC 404.8 Accessibility and Grouping. (A) Location. 2. Please seal Plenum ceiling penetration at AHU.R402.4, 3. Please seal or cap dryer duct (unless dryer is installed). M1502.4.7 Exhaust duct required.....Where the clothes dryer is not installed at the time of occupancy the exhaust duct shall be capped or plugged in the space in which it originates.... 4. Hot water discharge needs protected by landscape (mulch) from damage.FBC P305. Protection of components of plumbing 5. please seal wall penetration at doorbell transformer.R402.4, 6. Please seal wall penetration at main water supply shut off.R402.4, 7. Please seal ceiling Penetrations at garage door opener cat 5.R402.4,
BLD - BUILDING FINAL 03/28/2024 Disapproved - NO FEE JSTEWART
Note: 3/28/24- 1. Please Identify switch by garage to house door and Location height should be no more then 6'7" off the floor to the center of the control. Per NEC 404.8 Accessibility and Grouping. (A) Location. 2. Please seal Plenum ceiling penetration at AHU.R402.4, 3. Please seal or cap dryer duct (unless dryer is installed). M1502.4.7 Exhaust duct required.....Where the clothes dryer is not installed at the time of occupancy the exhaust duct shall be capped or plugged in the space in which it originates.... 4. Hot water discharge needs protected by landscape (mulch) from damage.FBC P305. Protection of components of plumbing 5. please seal wall penetration at doorbell transformer.R402.4, 6. Please seal wall penetration at main water supply shut off.R402.4, 7. Please seal ceiling Penetrations at garage door opener cat 5.R402.4,
ROW - FINAL APRON (AFTER POUR) 03/27/2024 APPROVED - AS NOTED FSLADISH
Note: 3/27/24 PIPE IS GOOD. CUTS MADE. CULVERT CLEAR. HOT PATCH COMPLETED AT THE TIME OF THIS INSPECTION. At the time of the inspection all minimum city requirements were met. It is the builders responsibiliy to ensure that nothing changes after this Inspection is approved. ________________________________________________________________________________________________________________________ Inspector Notes from Inspection 9465 3/26/24 PER MY CONVERSATION WITH GABE BERTOLA, WE ARE GOING TO PASS TIS FIELD SURVEY AS NOTED. YOU MAY BE REQUIRED TO MAKE ADDITIONAL CORRECTIONS UPON SUBSEQUENT INSPECTIONS DEPENDING ON FIELD CONDITIONS AT THAT TIME. 3/20/2024 - PREVIOUS INSPECTION NOTES 3/20/24 GOING TO MEET WITH JEFF TOMORROW 3/21/24 WITH REGARD TO 36 BUFFALO BILL DR.
ROW - STORMWATER FINAL 03/27/2024 APPROVED - AS NOTED FSLADISH
Note: 3/27/24 At the time of the inspection all minimum city requirements were met. It is the builders responsibiliy to ensure that nothing changes after this Inspection is approved. ________________________________________________________________________________________________________________________ Inspector Notes from Inspection 9465 3/26/24 PER MY CONVERSATION WITH GABE BERTOLA, WE ARE GOING TO PASS TIS FIELD SURVEY AS NOTED. YOU MAY BE REQUIRED TO MAKE ADDITIONAL CORRECTIONS UPON SUBSEQUENT INSPECTIONS DEPENDING ON FIELD CONDITIONS AT THAT TIME. 3/20/2024 - PREVIOUS INSPECTION NOTES 3/20/24 GOING TO MEET WITH JEFF TOMORROW 3/21/24 WITH REGARD TO 36 BUFFALO BILL DR.
U -UTILITY RESIDENTIAL FINAL 03/27/2024 FINAL APPROVED DHANEY
Note: Inspector Notes from Inspection 9035 No irrigation, no cross connections.
ROW FIELD SURVEY /GRADING CERTIFICATION 03/26/2024 APPROVED - AS NOTED FSLADISH
Note: 3/26/24 PER MY CONVERSATION WITH GABE BERTOLA, WE ARE GOING TO PASS TIS FIELD SURVEY AS NOTED. YOU MAY BE REQUIRED TO MAKE ADDITIONAL CORRECTIONS UPON SUBSEQUENT INSPECTIONS DEPENDING ON FIELD CONDITIONS AT THAT TIME. 3/20/2024 - PREVIOUS INSPECTION NOTES 3/20/24 GOING TO MEET WITH JEFF TOMORROW 3/21/24 WITH REGARD TO 36 BUFFALO BILL DR.
ROW FIELD SURVEY /GRADING CERTIFICATION 03/20/2024 CANCELLED BY APPLICANT FSLADISH
Note: 3/20/24 GOING TO MEET WITH JEFF TOMORROW 3/21/24 WITH REGARD TO 36 BUFFALO BILL DR.
U-CROSS CONNECTION 03/20/2024 APPROVED - AS NOTED JHARDING
Note: No irrigation, no cross connections.
ROW- FINAL SURVEY/GRADING CERTIFICATION 03/19/2024 APPROVED FSLADISH
Note: 3/7/2024 - PREVIOUS INSPECTION NOTES 3/7/24 THE CULVERT PIPE ELEVATION IS OUT OF TOLERANCE TO SWALE PLAN. Culvert Out of Tolerence Swale Plan #1 Swale Plan #1. The driveway culvert inverts are to be installed within 0.1' (+/-) of the elevations indicated on the swale plan (unless otherwise approved by the City StormwaterEngineer). The finished swale elevation is with sod in place YOUR ELEVATION SHOTS ALOG THE RIGHT SIDE PROPERTY LINE DO NOT SHOW POSITIVE REAR TO FRONT SWALE DRAINAGE. Rear Yard Drainage Sec 300.01(4,5,6) Sec 300.01(4,5,6) The tolerance along side lot lines is no more than 20 feet flat, with positive fall on each side.Positive fall is considered to be 0.10 feet in 20 feet.The minimum fall from the rear property line to the front is 0.50 feet. Rear Yard Drainage Sec 300.01(4,5,6) Sec 300.01(4,5,6) The tolerance along side lot lines is no more than 20 feet flat, with positive fall on each side.Positive fall is considered to be 0.10 feet in 20 feet.The minimum fall from the rear property line to the front is 0.50 feet Rear yard will be drained Section 300.01 Section 300.01.Identify how the rear yard will be drained. The rear yard is required to drain to the front yard swale. __________________________________________________________________________________________________________________________ Inspector Notes from Inspection 9270 ** 01/18/24 READY TO POUR ** At the time of the inspection all minimum city requirements were met. It is the builders responsibiliy to ensure that nothing changes after this Inspection is approved. This includes but is not limited to, the Culvert Pipe Elevation from the time of the inspection approval to the concrete pour. ** Sec.900.04C Residential driveways shall be constructed using material with a minimum of three thousand pounds (3,000 Ibs.) per square inch with Fiber or wire mesh. __________________________________________________________________________________________________________________ 1/16/2024 - PREVIOUS INSPECTION NOTES ** 01/16/24 SITE TOO WET _________________________________________________________________________________________________________________________ 1/12/2024 - PREVIOUS INSPECTION NOTES TOO MUCH WATER IN THE POUR AREA. WAY TOO SOFT TO POUR.
ROW- FINAL SURVEY/GRADING CERTIFICATION 03/07/2024 Disapproved - NO FEE FSLADISH
Note: 3/7/24 THE CULVERT PIPE ELEVATION IS OUT OF TOLERANCE TO SWALE PLAN. Culvert Out of Tolerence Swale Plan #1 Swale Plan #1. The driveway culvert inverts are to be installed within 0.1' (+/-) of the elevations indicated on the swale plan (unless otherwise approved by the City StormwaterEngineer). The finished swale elevation is with sod in place YOUR ELEVATION SHOTS ALOG THE RIGHT SIDE PROPERTY LINE DO NOT SHOW POSITIVE REAR TO FRONT SWALE DRAINAGE. Rear Yard Drainage Sec 300.01(4,5,6) Sec 300.01(4,5,6) The tolerance along side lot lines is no more than 20 feet flat, with positive fall on each side.Positive fall is considered to be 0.10 feet in 20 feet.The minimum fall from the rear property line to the front is 0.50 feet. Rear Yard Drainage Sec 300.01(4,5,6) Sec 300.01(4,5,6) The tolerance along side lot lines is no more than 20 feet flat, with positive fall on each side.Positive fall is considered to be 0.10 feet in 20 feet.The minimum fall from the rear property line to the front is 0.50 feet Rear yard will be drained Section 300.01 Section 300.01.Identify how the rear yard will be drained. The rear yard is required to drain to the front yard swale. __________________________________________________________________________________________________________________________ Inspector Notes from Inspection 9270 ** 01/18/24 READY TO POUR ** At the time of the inspection all minimum city requirements were met. It is the builders responsibiliy to ensure that nothing changes after this Inspection is approved. This includes but is not limited to, the Culvert Pipe Elevation from the time of the inspection approval to the concrete pour. ** Sec.900.04C Residential driveways shall be constructed using material with a minimum of three thousand pounds (3,000 Ibs.) per square inch with Fiber or wire mesh. __________________________________________________________________________________________________________________ 1/16/2024 - PREVIOUS INSPECTION NOTES ** 01/16/24 SITE TOO WET _________________________________________________________________________________________________________________________ 1/12/2024 - PREVIOUS INSPECTION NOTES TOO MUCH WATER IN THE POUR AREA. WAY TOO SOFT TO POUR.
U - SEWER TIE IN 02/20/2024 APPROVED MGIBSON
Note: Inspector Notes from Inspection 2075 U-SEWER AND OR SEWER TIE IN NEEDS TO BE SCHEDUALED ALONG WITH GRAVITY SEWER BOTH ARE APPROVED OK TOCOVER UP. SPOKE TO JEFF WISE HE WILL SCHEDUAL IT FOR 2/2O/24
GRAVITY SEWER TEST 02/16/2024 APPROVED - AS NOTED MGIBSON
Note: U-SEWER AND OR SEWER TIE IN NEEDS TO BE SCHEDUALED ALONG WITH GRAVITY SEWER BOTH ARE APPROVED OK TOCOVER UP. SPOKE TO JEFF WISE HE WILL SCHEDUAL IT FOR 2/2O/24
ELECTRIC - EARLY POWER 02/06/2024 APPROVED - AS NOTED JSTEWART
Note: 2/6/24- Please install chase above Garage breaker panel, to Protect Wireing from damage Before final. Inspector Notes from Inspection 2170 8/11/23-Authorize release of email to FPL @ 12:21p
ROW- PRE-APRON (PRE-POUR) 01/18/2024 APPROVED - AS NOTED EMADISON
Note: ** 01/18/24 READY TO POUR ** At the time of the inspection all minimum city requirements were met. It is the builders responsibiliy to ensure that nothing changes after this Inspection is approved. This includes but is not limited to, the Culvert Pipe Elevation from the time of the inspection approval to the concrete pour. ** Sec.900.04C Residential driveways shall be constructed using material with a minimum of three thousand pounds (3,000 Ibs.) per square inch with Fiber or wire mesh. __________________________________________________________________________________________________________________ 1/16/2024 - PREVIOUS INSPECTION NOTES ** 01/16/24 SITE TOO WET _________________________________________________________________________________________________________________________ 1/12/2024 - PREVIOUS INSPECTION NOTES TOO MUCH WATER IN THE POUR AREA. WAY TOO SOFT TO POUR.
ROW- PRE-APRON (PRE-POUR) 01/16/2024 CANCELLED BY APPLICANT EMADISON
Note: ** 01/16/24 SITE TOO WET _________________________________________________________________________________________________________________________ 1/12/2024 - PREVIOUS INSPECTION NOTES TOO MUCH WATER IN THE POUR AREA. WAY TOO SOFT TO POUR.
ROW- PRE-APRON (PRE-POUR) 01/12/2024 Disapproved - NO FEE GBERTOLA
Note: TOO MUCH WATER IN THE POUR AREA. WAY TOO SOFT TO POUR.
LATH/BRICK/ WATER BARRIER 01/03/2024 APPROVED AGAETANO
PEP TANK INSTALLATION REQUEST 01/02/2024 APPROVED TCHURCHILL
INSULATION 12/28/2023 CANCELLED BY APPLICANT WEB
Note: 12/27/2023 - PREVIOUS INSPECTION NOTES 12/27/23 - FIRESTOP ELECTRICAL PANEL IN GARAGE, LAUNDRY ROOM AND CHECK THROUGHOUT. REMOVE UNAPPROVED SEALANT AND REPLACE WITH APPROVED FIRESTOPPING, BATHROOM VENT. Inspector Notes from Inspection 2420 1. Right side of the building master bed closet missing 4" HVAC supply duct. 2. Nail plate at the dryer duct is to extend 2" below the bottom of the top plate. M-1308.2.1 Check for corrections at Insulation inspection.
INSULATION 12/28/2023 APPROVED JSTEWART
Note: New inspection due to canceled inspection 12/27/2023 - PREVIOUS INSPECTION NOTES 12/27/23 - FIRESTOP ELECTRICAL PANEL IN GARAGE, LAUNDRY ROOM AND CHECK THROUGHOUT. REMOVE UNAPPROVED SEALANT AND REPLACE WITH APPROVED FIRESTOPPING, BATHROOM VENT. Inspector Notes from Inspection 2420 1. Right side of the building master bed closet missing 4" HVAC supply duct. 2. Nail plate at the dryer duct is to extend 2" below the bottom of the top plate. M-1308.2.1 Check for corrections at Insulation inspection.
INSULATION 12/27/2023 Disapproved -FEE REQUIRED FWILLIS
Note: 12/27/23 - FIRESTOP ELECTRICAL PANEL IN GARAGE, LAUNDRY ROOM AND CHECK THROUGHOUT. REMOVE UNAPPROVED SEALANT AND REPLACE WITH APPROVED FIRESTOPPING, BATHROOM VENT. Inspector Notes from Inspection 2420 1. Right side of the building master bed closet missing 4" HVAC supply duct. 2. Nail plate at the dryer duct is to extend 2" below the bottom of the top plate. M-1308.2.1 Check for corrections at Insulation inspection.
ALL ROUGH 12/14/2023 APPROVED - AS NOTED JWALKER
Note: 1. Right side of the building master bed closet missing 4" HVAC supply duct. 2. Nail plate at the dryer duct is to extend 2" below the bottom of the top plate. M-1308.2.1 Check for corrections at Insulation inspection.
WALL SHEATHING 12/13/2023 APPROVED JSTEWART
ROOF VALLEY & METAL 12/13/2023 APPROVED JSTEWART
ROOF SHEATHING / BRACES/TIES/DOWN CELL 12/12/2023 APPROVED JSTEWART
Note: 12/8/2023 - PREVIOUS INSPECTION NOTES 12/8/23- No approved plans on site. DOCUMENTS MUST BE APPROVED AND KEPT ON SITE 107.3,1. AND SHALL BE OPEN TO INSPECTION BY THE BUILDING OFFICIAL
ROOF SHEATHING / BRACES/TIES/DOWN CELL 12/08/2023 Disapproved - NO FEE JSTEWART
Note: 12/8/23- No approved plans on site. DOCUMENTS MUST BE APPROVED AND KEPT ON SITE 107.3,1. AND SHALL BE OPEN TO INSPECTION BY THE BUILDING OFFICIAL
FOUND SURVEY APPROVED (OFFICE) 12/07/2023 APPROVED JGONZALEZ
TIE BEAM / LINTEL 09/28/2023 APPROVED FWILLIS
Note: 9/27/2023 - PREVIOUS INSPECTION NOTES 9/27/2023- Front entry columns need to be installed as shown on plans pg. S1 detail A-Front beam detail. detail shows 2 Reinforcement bars within the column, and Bond beams at the top with Lateral ties . 2 lateral ties within the first 5" of top, if Bond beam is not used per.. R606.12.2.3.2.
TIE BEAM / LINTEL 09/27/2023 Disapproved - NO FEE JSTEWART
Note: 9/27/2023- Front entry columns need to be installed as shown on plans pg. S1 detail A-Front beam detail. detail shows 2 Reinforcement bars within the column, and Bond beams at the top with Lateral ties . 2 lateral ties within the first 5" of top, if Bond beam is not used per.. R606.12.2.3.2.
MONOLITHIC SLAB 09/20/2023 CANCELLED BY APPLICANT WEB
MONOLITHIC SLAB 09/20/2023 APPROVED FWILLIS
PLUMBING 1ST ROUGH UNDERGROUND 09/15/2023 APPROVED MGIBSON
WATER METER INSTALLATION REQUEST 08/17/2023 APPROVED CBOWERMASTER
ELECTRIC TEMP POLE 08/11/2023 APPROVED - AS NOTED JSTEWART
Note: 8/11/23-Authorize release of email to FPL @ 12:21p

Review History

Department Status Date In Date Out
BLD COMPLETE 12/22/2023 12/22/2023
Note: Released By: PATRICK BUCKLEY - (386)986-3786 - PBUCKLEY@PALMCOASTGOV.COM
BLD HOLD 12/19/2023 12/22/2023
Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. Needs to be digitally signed and sealed
BLD HOLD 12/12/2023 12/15/2023
Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. Needs to be digitally signed and sealed
ZON COMPLETE 12/07/2023 12/07/2023
Note: Released By: JACQUELINE GONZALEZ - (386)986-3751 - JGONZALEZ@PALMCOASTGOV.COM Development Order for Adminstrative Deviation was approved 12/6/2023jg
ENGIN1 COMPLETE 11/08/2023 11/08/2023
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
ZON HOLD 11/08/2023 11/08/2023
Note: Held By: MICHELLE RAMOS - (386)986-3780 - MRAMOS@PALMCOASTGOV.COM The front setback on foundation plan doesn't meet the front setback.
MECH COMPLETE 11/07/2022 11/07/2022
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
ELEC COMPLETE 11/07/2022 11/08/2022
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
MECH HOLD 11/02/2022 11/02/2022
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM 1. Duct layout shows supply in garrage and return in wall in garage. Cannot have ductwork off house system. Revise duct layout. 2. Duct layout needs to be signed by AC contractor or signed and sealed by Engineer of record
ZON HOLD 10/26/2022 10/26/2022
Note: Held By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM Floor plan calculations have a door stoop. No other documents show a door stoop. Please remove in calculations or show location on all plans. Site plan/Survey must show a front entry walkway with material and width. Site plan/survey must show driveway width.
ZON COMPLETE 10/26/2022 10/26/2022
Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM
MECH HOLD 10/26/2022 10/26/2022
Note: Held By: CHRIS PISCITELLI - (386)986-3782 - CPISCITELLI@PALMCOASTGOV.COM 1. Duct layout shows supply in garrage and return in wall in garage. Cannot have ductwork off house system. Revise duct layout. 2. Duct layout needs to be signed by AC contractor or signed and sealed by Engineer of record
BLD COMPLETE 10/26/2022 11/02/2022
Note: Released By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM
ENGIN1 COMPLETE 10/26/2022 10/26/2022
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
SW1 COMPLETE 10/26/2022 11/02/2022
Note: Released By: GABRIEL BERTOLA - (386)986-7660 - GBERTOLA@PALMCOASTGOV.COM
BLD HOLD 09/28/2022 10/03/2022
Note: Held By: HAROLD ALLEN - (386)986-2357 - HALLEN@PALMCOASTGOV.COM All comments below per the 2020 Florida Building Code REVIEW COMMENTS: 1. Provide Detail F-5/S-1 for Garage slab.
CUSVC COMPLETE 09/28/2022 09/29/2022
Note: Released By: HALEIGH HAND - -
ELEC HOLD 09/28/2022 09/28/2022
Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. Need at least two outlets in the garage. NEC 2017 210.52 (G)(1) 2. Need outlet on the front of the house. NEC 2017 210.52 (E)(1)
ENGIN1 COMPLETE 09/28/2022 09/28/2022
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
LOCATE COMPLETE 09/28/2022 10/06/2022
Note: Released By: CANDACE STONE - - CSTONE@PALMCOASTGOV.COM
MECH HOLD 09/28/2022 10/04/2022
Note: Held By: CHRIS PISCITELLI - (386)986-3782 - CPISCITELLI@PALMCOASTGOV.COM 1. R403.7.1.2.1 FBC Energy Conservation 2020 7TH Edition- Chosen equipment exceeds the maximum of 1.15 times the load calculated. 2. Provide Duct layout signed by the AC contractor
SW1 COMPLETE 09/28/2022 10/06/2022
Note: Released By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM NEED TO PUT THE BERM FERTHER BACK TO THE PROPERTY LINE
ZON HOLD 09/28/2022 09/28/2022
Note: Held By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM Floor plan calculations have a door stoop. No other documents show a door stoop. Please remove in calculations or show location on all plans. Site plan/Survey must show a front entry walkway with material and width. Site plan/survey must show driveway width.
SWALE COMPLETE 09/28/2022 01/31/2023
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
REINSPECTION RESIDENTIAL ¤40.00 12/27/2023
CONNECTION FEES ¤1,166.26 05/11/2023
3% FIRE IMPACT FEE CREDIT (¤11.66) 05/11/2023
IMPACT FEE FIRE ¤388.65 05/11/2023
IMPACT FEE PARKS ¤1,455.13 05/11/2023
IMPACT FEE SCHOOL ¤5,450.00 05/11/2023
IMPACT FEE TRANSPORTATION ¤1,764.00 05/11/2023
WATER -IRRIGATION INSPECTION ¤25.00 05/11/2023
3% PARKS IMPACT FEE CREDIT (¤43.65) 05/11/2023
SURCHARGE FS 533.721 ¤3.27 05/11/2023
SURCHARGE - FS 468.631 ¤4.91 05/11/2023
SW ENG - FOUNDATION SURVEY ¤20.00 05/11/2023
SW ENG INSPECTION 80 ¤80.00 05/11/2023
SW ENG PRE APRON ¤30.00 05/11/2023
SW ENG - REVIEW 20 ¤20.00 05/11/2023
SW ENG RES REVIEW 200 ¤200.00 05/11/2023
3% TRANS IMPACT FEE CREDIT (¤52.92) 05/11/2023
SEWER CREDIT (¤850.00) 05/11/2023
SEWER INSPECTION ¤25.00 05/11/2023
SEWER CAPITAL FACILITY ¤5,344.82 05/11/2023
WATER CAPITAL FACILITY FEE ¤3,923.88 05/11/2023
SITE PLAN 30 ¤30.00 05/11/2023
WATER- TURN ON ¤25.00 05/11/2023
ADJUSTMENT 50% (¤505.67) 05/11/2023
ADMINISTRATIVE RESIDENTIAL ¤30.00 05/11/2023
INSPECTION - RESIDENTIAL ¤764.50 05/11/2023
PLAN REVIEW - RESIDENTIAL ¤216.84 05/11/2023
Fees Total Due: ¤0.00 Total Paid: ¤19,543.36